HomeMy WebLinkAboutFile Documents.731 E Durant Ave.0031-2023-BRES (8) , 1:411111- • 1 __ ,_________ _ URBANA LUXURY FIREPLACES A 1.150 U5OT 1 -.• .'ii.N.1141.1P:=•-+...•-•- - I."'7............"'"""'"''.. - I I i u70T _ ......__ INSTALLATION GUIDE Refer to Owner's Manual for specific installation requirements and additional product instructions 08"[203mm] 1 116"[27mm] 05"[127mm] 358"[898mm] 1 ri 1 I _ i 4 i s 72"[190mm] E U50/U70 DIMENSIONS o 7 Note-The U50 and U70 physical `r • :• ._ ••-• 1316"[341 m m] = dimensions only differ in width TU70/U70T=71 3/4"[1822mm] U50/U5OT=51 3/4"[1314mm] U70/U7OT=70 3/4"[1797mm] U50/U5OT=50 3/4"[1289mm] i 2016"[532mm] 1 ,• • • . . • ., E C — i= EN ® ov EM 1 A •ao E v E 01= o � o� p• _ ,�,� E h 1 O E N V 7 O �� ^M M P a CO _O 'n 7 CO N V O H 00 n ^ `O n O CV co 1—^O =n.0 O CO N O O r \O F • O O N ▪ I- =141 n 1> 1> ' =1 a WI,'" 1�' 1 1 �� ="' .i.. kwU70/U7OT=62 5/16"[1583mm] U50/U5OT=42 5/16"[1075mm] 15 16"[395mm] 116"[39mm] Q RECEIVED t-wm‘i 512p23 04/25/2023 00 (fea � ASPEN �M BUILDING DEPARTMENT U R B A N A U50 / U70 INSTALLATION GUIDE LUXURY FIREPLACES TOP RELEASE/OPEN CHASE CHASE DIMENSIONS&CLEARANCES F The U50 and U70 fireplaces must be installed with both an intake at the bottom of the chase and a heat release at the top of the chase.A variety of installation styles are permitted as shown in the following illustrations.Refer to Table 1 for the required dimensions corresponding to the letters in the illustrations. WARNING RISK OF FIRE HAZARD - The minimum ~ g� dimensions,clearances and areas outlined within this guide MUST A be followed along with those stated in the Owner's Manual. TABLE 1 LETTER DIMENSION E 1 A U50/U70 88 1/2"(2248 mm) U50T/U7OT 95 1/8"(2416 mm) 21"(533 mm) Top only heat release with front&sides intake U50/U5OT 50 3/4"(1289 mm) U70/U7OT 70 3/4"(1797 mm) FRONT&SIDES W/FALSE D 9 15/16"(253 mm) CEILING E Minimum 1 1/2"(38 mm) J \%� F U50/U5OT Minimum 170 in2(1097 cm2) U70/U7OT Minimum 210 in2(1355 cm2) F U50/U5OT Minimum 135 in2(871 cm2) F G U70/U7OT Minimum 165 in2(1064 cm2) H U50/U70 17 3/8"(441 mm) U5OT/U7OT 24"(610mm) 0- 1 1/2"(0-38 mm) Maximum -� B A J Minimum 2"(51 mm) E � At RECEIVED Heat release and int front&sides,chase t Sgll1 2 2 04/25/2023 CA ymi ASPEN ftg - BUILDING DEPARTMENT CLEARANCES I FRAMING I VENTING FRONT ONLY SIDES ONLY F I iiiimmF ' ZI ' -� B�. ~B�. A I I H H � G Heat release and intake on the front of the chase only. Heat release and intake on the sides of the chase only. Note-Installations with only 1 side of the chase utilized for either intake or heat release are not permitted. ALCOVE/SIDEWALL CLEARANCE Minimum clearance to a sidewall constructed or finished with combustible material. [178mm] [178mm] Note-Side wall clearance not applicable for closed off side if using corner kit(s). SPRINKLER CLEARANCES UJ i �? Minimum clearance to a sprinkler head from the Chase Heat Release Minimum 5'[1.5m] chase heat release in any direction. RECEIVED \et-425I2° 04/25/2023 am00,40. ASPEN -�''� BUILDING DEPARTMENT U R B A N A U50 / U70 1 INSTALLATION GUIDE LUXURY FIREPLACES IMPORTANT NOTE: Framing above the fireplace CANNOT BE CONSTRUCTED prior to fireplace installation,the fireplace and its required shielding WILL NOT FIT! MINIMUM CHASE FRAMING All chase framing may be wood 2x4 construction or the like.Combustible material is permitted for any area of the chase and no 44111 steel studs are required.Chase may be framed Minimum beyond minimum framing for taller ceilings, Ceiling. overhangs etc. U50/ U70 r Note-Top of chase must be enclosed,cannot be 88 1/2[225cm] open to joists or rafters above. Note-The fireplace is not load bearing and U50T/ U7OT /951/8" the chase must be constructed to fully support [242cm]finishing material. 4 - Maximum Front and Side Header depth=1 1/2" U50=50 3/4" / [129cm] I (wood 2x4 on edge) U70= 70 3/4" U50/ U70 [180cm] 37" [94cm] 21" [533mm] U50T/ U7OT Fireplace must be installed on a solid 43 5/8" [1 1 1 cm] plywood or similar floor with a minimum width equal to the fireplace leveling legs �L All MINIMUM THIMBLE HEIGHT MI As measured from the bottom of the fireplace to the center line II of the vent.The fireplace uses 5"x 8"co-axial rigid or flex venting. Note-additional adaptors(50-3789)required for flex venting U50 / U70 = 79 3/4" [2026mm] U5OT / U7OT = 86 3/8" [2194mm] 43/4" 121mm] MINIMUM CHASE ELBOW CLEARANCE \iI This clearance only applies to an elbow I' that is located within the chase.Once 111146. — =•,■ 1 outside of the chase standard venting clearances apply. — i ` RECEI :0 o41251 p23 04/25/P02c ( � ASPEN 1./''� . BUILDING DEPARTMENT CLEARANCES I FRAMING I VENTING o� ■o I a I I • POWER AND GAS The incoming gas and power connections are located on the left and right on the back of the fire lace as shown.The incomin Powes Vent In ut p g Gas Inlet Access p power junction box is located underneath Power the left side louver and is removable to aid 2" 51 mm with wiring. i!PL I 4 3/4" [121 mm] 211/16" 68mm 11 7/8" 302mm EXTENDED HEARTH /PLINTH An extended hearth or plinth may be constructed around the base of the fireplace up to the bottom tiling edge. Combustible material is permitted for construction and finishing of the plinth.Alternatively the optional 50-3824 Steel Framing Base Kit can also be used.The finished depth of the plinth cannot exceed 12"[305 mm]and minimum intake dimensions must be maintained.If raising the unit is desired a Flush Framing Base Kit(U50=50-4008,U70=50-4031)may be used to achieve a rise of 6"-11"off the floor. Note:50-3824&50-4002/50-4031 cannot be used together 12" [305mm] Maximum finished depth from cabinet I 1 1/2" [38mm] im opening heightMin fromu m finished floor OVERHANG/MANTLE CLEARANCES An overhanging chase or mantle may be constructed above Front and Sides Maximum Finished the fireplace comprised of combustible framing and finishing Depth = 12" [305mm] material.The maximum finished depth of an overhanging chase or mantle cannot exceed 12"[305 mm].There is no minimum height restriction and the finished surface can be flush with the top tiling edge. U50/ U70=29" [737mm] U50T/ U70T= 35 5/8" [905mm] \J � 1 R IVED v _ _ 25 31,: •:,,u."1./2023 i( ,; ASPEN BUILDING DEPARTMENT U R B A N A U50 / U70 INSTALLATION GUIDE LUXURY FIREPLACES HDTV CLEARANCES A TV may installed above the fireplace either on a flat wall or within a shelf or recess as shown below.When flat wall mounting a TV,the minimum permitted height may need to be increased to prevent the mounting screws from penetrating the fireplace cabinet. It is the responsibility of the home owner to confirm that the TV is within its maximum allowable operating temperature range once installed.Sherwood Industries is not liable for any TV malfunctions or adverse effects that may be incurred. FLAT WALL MOUNTED SHELF/RECESS MOUNTED Maximum to top of chase 1 1/2" [38mm] Maximum to top of chase 1 1/2" [38mm]i �G IXI I X !XI 1 t Minimum Opening Area X �1 U50= 170 in2/ U70= 210in2 Minimum Clearance from Heat Release 12" [305mm] *Not shown to scale Maximum Framed Depth ' 5" [127mm] • x x Minimum X Framed • - Height • Minimum Clearance • 20" [508mm] • from Top Flange _ . 4" [102mm] •••• • •• •_ • Maximum Finished Depth 12"[305mm] I I T1_' "k—" I I I 17_1'. • / Y jOt ;EIVED yr„/25/2°23 04/25/2023 C am0- ASPEN -�''� BUILDING DEPARTMENT CLEARANCES I FRAMING I VENTING 1' Minimum to 9' Maximum Vent Run © Minimum Rise Alf1 It1lIE=NM 3'Single Section MINIMUM VENTING Minimum Vent Rise The fireplace utilizes 5"x 8"rigid co-axial venting. Alternatively 5"x 8"flex venting may be used when using additional vent adaptors(50-3789).Refer to the Owner's Manual for more detailed venting and restriction information. Sidewall Soffit/Overhang Clearance2 12" [305mm] HORIZONTAL TERMINATION CLEARANCES Clearance' 24" [610mm] The clearances shown in the illustration must be followed when horizontally terminating the fireplace.Additionally, :g: a termination guard must be used when the termination is $a I installed in an area where it could be contacted.Only high i• wind terminations are permitted for installation. 1/2" [38mm] Note-Termination clearances not applicable for power vent Standoff installations.See power vent manual. Soffi Olt fthe�tA fi�E ED 2Sidewall .dso4�e6fr� s� of the tE piin2t9'02023 CPCam� ASPEN �''� BUILDING DEPARTMENT URBANA LUXURY FIREPLACES urbanafireplaces.com Q RECEIVED Manufactured by Sherwood Industries Ltd. • Victoria,BC,Cam 0 ,L52023 04/25/2023 Printed in Canada. 04 gt( ASPEN BUILDING DEPARTMENT