Asbestos Sampling Report
Date:3/30/2017 Property Address
Date of Inspection: 03/28/2017 503 N. Fourth St.
Aspen, CO 81611
Client:
Michael Edinger
Attn: TABLE OF CONTENTS
Sean McNanie
1.0 -Scope of Work
2.0 -Sampling Requirements
3.0 -Sampling Methodology
4.0 - Laboratory
5.0 -Suspect Materials Sampled
6.0 -Table of Results
7.0 - Description of Sampling Area
Building Inspector: 8.0 - Conclusion
- Lab Report
Joshua Johnson - Certifications
CDPHE#18401 Asbestos Samples Analyzed: 7
Positive Asbestos Samples: 0
RECEIVED
ELEMENT ENVIRONMENTAL I Edin9e`5r 03 81iii3Pna2nie
ASPEN
BUILDING DEPARTMENT
1.0- This was an inspection for suspect ACM (Asbestos Containing Material) for a remodel.
Element Environmental conducted a visible inspection for visible materials that would
be impacted during the remodel. This inspection was limited to the areas found in the
Description of the Sampling Area 7.0. Although sampling is destructive in nature, this
was a non-invasive inspection. It was of materials that were accessible. If other suspect
materials become visible/apparent during demolition or construction activities, work in
that area should be halted and more sampling/testing must take place, per Colorado
regulations. Any suspect materials that were not tested are to be assumed to contain
asbestos.
2.0- A limited bulk sampling of from all suspect materials was conducted in accordance with
Colorado State Requirements. The minimum number of samples per homogenous areas
are as follows:
2.1- Surfacing Materials- >1,000 sq.ft.- Minimum of 3 samples
1,000 sq.ft.- 5,000sq.ft.- Minimum of 5 samples
>5,000 sq.ft. Minimum of 7 samples
2.2- Miscellaneous materials- Minimum of 1 sample
2.3-Thermal Systems Insulation (TSI)- Minimum of 3 samples
3.0- The purpose of the inspection is to identify materials that are homogenous. A
homogeneous area is defined as one which shares suspect material, texture, color,
location, and/or apparent time of construction. The materials are segregated into
separate homogenous areas. The size is determined and then samples are taken. The
samples are taken in a random numerical sequence.
4.0- Josh Johnson, a Colorado Department of Public Health & Environment certified building
inspector, certification number: 18401, performed the inspection. Samples taken were
sent to CEI Labs in Cary, North Carolina. The samples were analyzed by PLM (Polarized
Light Microscopy) analysis. Per the CDPHE Regulation any sample that is found by a lab
to be trace, or<1% asbestos, is considered to be ACM material. This material would still
be a regulated material by CDPHE. The sample most have an additional "point count"
performed to be considered less than 1% and not be regulated by the CDPHE. The lab's
documents with analyses and findings are found below.
RECEIVED
ELEMENT ENVIRONMENTAL I Edinger 03�A 3F,'?l
ASPEN
BUILDING DEPARTMENT
5.0- SUSPECT MATERIALS SAMPLED
• Texture • Joint Compound
• Drywall • Insulation
• Tape
6.0- TABLE OF RESULTS
HOMOGENOUS DESCRIPTION OF AREA CATEGORY NUMBER OF APPROXIMATE %AND TYPE OF
AREA & SAMPLES SQ.FT. ASBESTOS FOUND
FRIABILITY
(A) Smooth Roll Texture S/ N/A 6 -4,000f2 No Asbestos Detected
(B) White Insulation M / N/A 1 -4,000f2 No Asbestos Detected
Key: N-No
S-Surfacing Y-Yes
M-Miscellaneous N/A-Not Applicable
T-Thermal Systems Insulation
7.0- DESCRIPTION OF SAMPLING AREA
• The main level and upstairs were tested for an extensive remodel.
8.0- CONCLUSION
No asbestos was detected in any of the samples.
Josh Johnson,
e e m e n t J O S H U A JOHNSON president
rd 135 glenwood springs.co 81601 g70.274.3139
ENVIRONMENTAL INC
ASBESTOS ENVIRONMENTAL RESTORATION
RECEIVED
ELEMENT ENVIRONMENTAL I Eding9e`5r 14$17 3PnaZnl
ASPEN
BUILDING DEPARTMENT
4
ASBESTOS BULK ANALYSIS
CI By: POLARIZING LIGHT MICROSCOPY
LABS
Client: Element Environmental LLC CEI Lab Code: A17-4636
189 CR 135 Date Received: 03-29-17
Glenwood Springs,CO 81601 Date Analyzed: 03-29-17
Date Reported: 03-29-17
Project: Edinger 032817 Sean
ASBESTOS BULK PLM,EPA 600 METHOD
Client ID Lab Lab NON-ASBESTOS COMPONENTS ASBESTOS
Lab ID Description Attributes Fibrous Non-Fibrous
503 Al Texture Heterogeneous <1% Cellulose 5% Paint None Detected
Layer 1 White 20% Silicates
A2362934 Fibrous 75% Calc Carb
Bound
Layer 2 Sheetrock Heterogeneous 10% Cellulose 90% Gypsum None Detected
A2362934 White,Tan
Fibrous
Bound
503 A2 Texture Heterogeneous <1% Cellulose 5% Paint None Detected
Layer 1 White 20% Silicates
A2362935 Fibrous 75% Calc Carb
Bound
Layer 2 Sheetrock Heterogeneous 10% Cellulose 90% Gypsum None Detected
A2362935 White,Tan
Fibrous
Bound
503 A3 Texture Heterogeneous <1% Cellulose 5% Paint None Detected
Layer 1 White 20% Silicates
A2362936 Fibrous 75% Calc Carb
Bound
Layer 2 Sheetrock Heterogeneous 10% Cellulose 90% Gypsum None Detected
A2362936 White,Tan
Fibrous
Bound
503 A4 Texture Heterogeneous <1% Cellulose 5% Paint None Detected
Layer 1 White 20% Silicates
A2362937 Fibrous 75% Calc Carb
Bound
Page 1 of 3
RECEIVED
ELEMENT ENVIRONMENTAL I Eding9e`-14£11 3Pn?nle
ASPEN
BUILDING DEPARTMENT
PIPPIPP
ASBESTOS BULK ANALYSIS
By: POLARIZING LIGHT MICROSCOPY
C C !LADS
Client: Element Environmental LLC CEI Lab Code: A17-4636
189 CR 135 Date Received: 03-29-17
Glenwood Springs,CO 81601 Date Analyzed: 03-29-17
Date Reported: 03-29-17
Project: Edinger 032817 Sean
ASBESTOS BULK PLM, EPA 600 METHOD
Client ID Lab Lab NON-ASBESTOS COMPONENTS ASBESTOS
Lab ID Description Attributes Fibrous Non-Fibrous
Layer 2 Sheetrock Heterogeneous 10% Cellulose 90% Gypsum None Detected
A2362937 White,Tan
Fibrous
Bound
503 A5 Texture Heterogeneous <1% Cellulose 5% Paint None Detected
Layer 1 White 20% Silicates
A2362938 Fibrous 75% Calc Carb
Bound
Layer 2 Sheetrock Heterogeneous 10% Cellulose 90% Gypsum None Detected
A2362938 White,Tan
Fibrous
Bound
503 A6 Texture Heterogeneous <1% Cellulose 5% Paint None Detected
Layer 1 White 20% Silicates
A2362939 Fibrous 75% Calc Carb
Bound
Layer 2 Sheetrock Heterogeneous 10% Cellulose 90% Gypsum None Detected
A2362939 White,Tan
Fibrous
Bound
503 B1 Insulation Heterogeneous 95% Fiberglass 5% Binder None Detected
A2362940 White
Fibrous
Loosely Bound
Page 2 of 3
RECEIVED
ELEMENT ENVIRONMENTAL I Eding9e`5r 04$17 13Pnaa2nl
ASPEN
BUILDING DEPARTMENT
6
CEI LASS
LEGEND: Non-Anth =Non-Asbestiform Anthophyllite
Non-Trem = Non-Asbestiform Tremolite
Calc Carb =Calcium Carbonate
METHOD: EPA 600/R93/116 and EPA 600/M4-82/020
REPORTING LIMIT: <1%by visual estimation
REGULATORY LIMIT: >1%by weight
Due to the limitations of the EPA 600 method, nonfriable organically bound materials (NOBs)such as
vinyl floor tiles can be difficult to analyze via polarized light microscopy (PLM). EPA recommends that
all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission
Electron Microscopy(TEM). Please note that PLM analysis of dust and soil samples for asbestos is not
covered under NVLAP accreditation. Estimated measurement of uncertainty is available on request.
This report relates only to the samples tested or analyzed and may not be reproduced, except in full,
without written approval by CEI Labs, Inc. CEI Labs makes no warranty representation regarding the
accuracy of client submitted information in preparing and presenting analytical results. Interpretation of
the analytical results is the sole responsibility of the client. Samples were received in acceptable
condition unless otherwise noted. This report may not be used by the client to claim product
endorsement by NVLAP or any other agency of the U.S.Government.
ANALYST: APPROVED BY: lGw,/S
yan Williams Tianbao Bai,Ph.D.,CIH
Laboratory Director
NVLA
TESTING
NVLAP LAB CODE 101768-0
Page 3 of 3
RECEIVED
ELEMENT ENVIRONMENTAL I Edingge`rr 03Lo17 �c�naanl
ASPEN
BUILDING DEPARTMENT
Pili;:', ,,,,, ", ',!.,,1/4:=,1,.;,;.<.\ , -.,,‘,,,, -,,, , .,,,, ,-.,,-,,,,,,,,,,...1-:.s,,,e,,. .,:.,.,_
Colorado Department :Zoe,'
of Public Health
and Environment
' - ASBESTOS
` CERTIFICATION*
Nor_
?m This certifies that
17 frlIS '
! Joshua Jay Johnson '
c Certification No.:18401 - j
f` has met the requirements of 25-7-507,C.R.S.and Air Quality Control -=
Commission Regulation No.8,Part B,and is hereby certified by the
Istate of Colorado in the following discipline: 5
;
Building Inspector*
Issued: July 13,2016a -
p Expires: July 13,2017 s i
rMl mrPanre lr�vdld xxry lM1 rlepusenfxn o/a
erxr flnr rd ImxBro.,u lmeonIiirlaZel= S
e- �. �. �. �. ♦-
c
1 ',Ili,- e _C.
Colorado Department f ,"`'.-tl
of Public Health
and Environment
/
ASBESTOS CONSULTING FIRM �0`
This certifies that
�14 Element Environmental LLC
ag . Registration No.:ACF-21640P,•;1:
r;_ has met the registration requirements of 25-7-507,C.R.S.and the Air Quality Control
-•4 Commission Regulation No.8.Part B,and is hereby authorized to perform asbestos consulting A,
t C;_ activities as required under Regulation No 8,Part B,in the state of Colorado. ?�
`4.
Issued: January 07.2017 r7/�/// �; '1
- - Expires: January 07,2018 �4� /-4%-i'(:
MuMmx.a NPCn fbpes.*. t
i 1, _ 961E ?.
7 1 ws- } $r"n al x drr3 t"{vl,r11ll cgiy.:a<i t P r , s`'ajrit$ _`
' c+7a', J,3•P Ser ,.W t? ,;i a,i'7,rK a..1.,..-R#3` -1, + r,ae;-.3 sr4l z,i ?
RECEIVED
ELEMENT ENVIRONMENTAL I Edingge`rr 03Loi7 �c�naanle
ASPEN
BUILDING DEPARTMENT