Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.555 E Durant Ave.0025-2022-BRES (22)
MXZ-5C42NA2 MITSUBISHI MULTI-ZONE INVERTER HEAT-PUMP SYSTEM M_ELECTRIC Job Name: System Reference: Date: MITSUBISHI EL llIIIIIIIIIIIIIiIIIIIII :1III. 111111IIIIIIIIIIIIIIIIIiI 1111 jjIIIIIIIIh, . 1IIIIEiiIIIIIIiIIIIIII!IIIIIIIIIIIIIIIIIIIIIII1 !IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII' ''IIIIIIIIIIIIIIIIIIIIIIIiOP!!IIIIIIpII' "`i1II1IIIIIIIIIII 11:::”' • ind FEATURES • Variable speed INVERTER-driven compressor • Optional base pan heater • Quiet outdoor unit operation as low as 58 dB(A) • High pressure protection • Compressor thermal protection • Compressor overcurrent detection • Fan motor overheating/voltage protection RECEIVED 03/14/2022 ASPEN BUILDING DEPARTMENT Specifications are subject to change without notice. ©2021 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SPECIFICATIONS: MXZ-5C42NA2 (FOR DATA ON SPECIFIC INDOOR UNITS,SEE THE MXZ-C TECHNICAL AND SERVICE MANUAL.) Rated Capacity Btu/h 40,500/37,400 Cooling* Capacity Range Btu/h 12,600-43,000 (Non-ducted/Ducted) Rated Total Input W 4,403/4,112 IP Rated Capacity Btu/h ` 45,000/41,000 Heating at 47°F* Capacity Range Btu/h 11,400-53,600 (Non-ducted/Ducted) Rated Total Input W 3,575/3,463 Heating at 17°F* Rated Capacity Btu/h 24,400/23,000 (Non-ducted/Ducted) Rated Total Input W 2,943/2,869 Connectable Capacity Btu/h 12,000-51,000 Power Supply Voltage,Phase,Hertz 208/230V,1-Phase,60 Hz Electrical Requirements Recommended Fuse/Breaker Size A 40 MCA A 32.5 Indoor-Outdoor S1-S2 AC 208/230 Voltage Indoor-Outdoor S2-S3 DC±24 Compressor INVERTER-driven Scroll Hermetic Fan Motor(ECM) F.L.A. 2.43 Cooling dB(A) 56 Sound Pressure Level Heating dB(A) 58 In 41-9/32 x 37-13/32 x 13 External Dimensions(H x W x D) mm (1048 x 950 x 330) Net Weight Lbs/kg 189(86) External Finish Munsell No.3Y 7.8/11 Liquid(High Pressure) In/mm 1/4(6.35) Refrigerant Pipe Size O.D. Gas(Low Pressure) In/mm A:1/2(12.7);B,C,D,E:3/8(9.52) Max.Refrigerant Line Length t/m '62(80) Max.Piping Length for Each Indoor Unit Ft/m 82(25) II Max.Refrigerant Pipe Height If IDU is Above ODU Ft/m 49(15) Difference If IDU is Below ODU Ft/m 49(15) Connection Method Flared/Flared Refrigerant - . R410A *Rating Conditions perAHRI Standard: Cooling I Indoor:80°F(27°C)DB/67°F(19°C)WB Heating at 47°F I Indoor:70°F(21°C)DB Heating at 17°F I Indoor:70°F(21°C)DB Cooling I Outdoor:95°F(35°C)DB/75°F(24°C)WB Heating at 47°F I Outdoor:47°F(8°C)DB/43°F(6°C)WB Heating at 17°F I Outdoor:17°F(-8°C)DB/15°F(-9°C)WB OPERATING RANGE: ENERGY EFFICIENCIES: Outdoor Indoor Unit Type SEER EER HSPF COP @ 47°F COP @ 17°F Cooling 14 to 115°F(-10 to 46°C)DB Non-ducted 19.7 9.2 10.30 3.69 2.43 (06+09+09+09+09) Heating 5 to 65°F(-15 to 18°C)WE Ducted and 17.5 9.1 9.70 3.58 2.39 Non-ducted Ducted 15.2 9.0 9.10 3.47 2.35 (09+09+09+09+09) NOTES: For actual capacity performance based on indoor unit type and number of indoor units connected,please refer to MXZ Operational Performance. Although the maximum connectable capacity can exceed rated,the outdoor unit cannot provide more than 100%of the rated capacity.Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. RECEIVED 03/14/2022 ASPEN BUILDING DEPARTMENT Specifications are subject to change without notice. ©2021 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. OUTDOOR UNIT ACCESSORIES: MXZ-5C42NA2 Air Outlet Guide Air Outlet Guide(1 Piece) 0 PAC-SH96SG-E(two pieces are required) Refrigeration Ball Valve-1/2" 0 BV12FFSI2 Refrigeration Ball Valve-1/4" 0 BV14FFSI2 Ball Valve Refrigeration Ball Valve-3/8" 0 BV38FFSI2 Refrigeration Ball Valve-5/8" 0 BV58FFSI2 Distribution pipe for Branch Box M-NET Converter 0 PAC-IF01 MNT-E Drain Socket Drain Socket 0 PAC-SG6ODS-E Hail Guards Hail Guard 0 HG-Al Condensing Unit Mounting Pad:16"x 36"x 3" 0 ULTRILITE1 Mounting Pad Outdoor Unit 3-1/4 inch Mounting Base(Pair)-Plastic ❑ DSD-400P Optional Defrost Heater Optional Defrost Heater 0 PAC-645BH-E Adaptor:1/2"x 3/8" 0 MAC-A455JP-E Adaptor:1/2"x 5/8" 0 MAC-A456JP-E Port Adapter Adaptor:3/8"x 1/2" 0 MAC-A454JP-E Adaptor:3/8"x 5/8" 0 PAC-SG76RJ-E Power Supplies and Auxiliary Components M-Net Control Wire,1,000'Roll(16-AWG,Standard,Twisted Pair,Shielded,Jacketed-Plenum rated) ❑ CW162S-1000 Power Supplies And Auxiliary Components M-Net Control Wire,250'Roll(16-AWG,Standard,Twisted Pair,Shielded,Jacketed-Plenum rated) ❑ CW162S-250 18"Single Fan Stand 0 QSMS1801 M 24"Single Fan Stand 0 QSMS2401 M Stand Condenser Wall Bracket 0 QSWB2000M-1 Condenser Wall Bracket-Stainless Steel Finish 0 QSWBSS Outdoor Unit Stand—12"High 0 QSMS1201 M RECEIVED 03/14/2022 ASPEN BUILDING DEPARTMENT Specifications are subject to change without notice. ©2021 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. OUTDOOR UNIT DIMENSIONS: MXZ-5C42NA2 Unit: inch .-7/B' 23-5/8' .-7/8' 11/ Rear Air Intake 2-13/16" 27/32" 4-19 2-1/32'. 2-U Shaped Notched Hole 13/32'i3-3/16" (Foundation Bolt M10) ii A ,. IIf"ice- 1 �11IN Side Air Intake* 11� I \ �1 . a m 1 N i m I a m ilr. 6-01-5/16'Drain Hole l 13/32' Air N I13/32' 01-3/32"punched hole A. Discharge (Connecting wire hole) 2-(15/32'01-13/32')Oval Hole 2-07/8'punched hole (Foundation Bolt M10) 2-15/16' (Connectin• wire hole) 2-3/32'MI 1-5/32'Ill 3-07/8punched hole 37-13/32' . 31/32' 13' 19/32' III (Connecting wire hole) �I �® Handle ^ 'I,! I Handle j® .1 WM— -\. Air int.k- Handle I ) 4�'�. Handle III �h, I . ;.III'IM, II, _a m 1i-__ i I .. I 7 ( )M Ill: ii c;: IP I IilI 2-3/4' =rM■ l j® IIIMO.:' �l+n GAS}Dnit E l 1® v 1;11;1I LID ® "lIII'i /- I '� 11 GAS�Unif D LIO 1/4'106.351FLARE !� = ��alio. t LIO GA53/8'106.52)FLARE l jl5 IIII .:� • I`I11 GAS�UnIf C • I- l ®� � II{III GAS}DnIt B ��3III LIO l LIO 1/4'(0135)FLARE Ip y -- I j® j�r� l'J GAS JUnIf A-GA51/2'(012.7)FLARE 1 ]®' • I-Id dim nel I 1-5/16" k 14-7/32' ui 1.FREE SPACE Conduit plate Top E E 2 E O 3-15/16" or more 1:: o o ail l `1 II` 3-15/16' or mare 13-25/32' or more 7l '4- (Il�� 2.SERVICE SPACE O` '�'�� It sc ,,, Lock nut Conduit connector ci, Conduit plate Under 3-15/16' or more SERVICE SPACE 13-25/32' or 13-25/32' or 1340 Satellite Boulevard Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com AM CERTIFIED° D b u FORM#M_SUBMITTAL_MXZ-5C42NA2_en-202103 0we022 ASPEN BUILDING DEPARTMENT Specifications are subject to change without notice. ©2021 Mitsubishi Electric Trane HVAC US LLC.All rights reserved.