Loading...
HomeMy WebLinkAboutFile Documents.731 E Durant Ave.0031-2023-BRES (11) irifl COMcheck Software Version COMcheckWeb Envelope Compliance Certificate Project Information Energy Code: 2021 IECC Project Title: Location: Aspen, Colorado Climate Zone: 7 Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 731 E DURANT#7 ASPEN, Colorado 81611 Building Area Floor Area 1-UNIT 7(Multifamily) : Residential 1068 Envelope Assemblies Envelope TBD: No envelope assemblies specified Project Title: Re o t6: / 6 D Data filename: tie/3.dik 072 3 ASPEN BUILDING DEPARTMENT irifl COMcheck Software Version COMcheckWeb Interior Lighting Compliance Certificate Project Information Energy Code: 2021 IECC Project Title: Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 731 E DURANT#7 ASPEN, Colorado 81611 Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed (ft2) Watts /ft2 Watts 1-UNIT 7 (Multifamily) 1068 0.45 481 Total Allowed Watts = 481 Proposed Interior Lighting Power A B C D E Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixture Watt. UNIT 7 (Multifamily, 1068 sq.ft.) Total Proposed Watts = N/A Interior Lighting TBD: Alteration details not specified Project Title: RenterPig!) Data filename: ue/162ik 072 3 ASPEN BUILDING DEPARTMENT COMcheck Software Version COMcheckWeb (ICI Exterior Lighting Compliance Certificate Project Information Energy Code: 2021 IECC Project Title: Project Type: Alteration Exterior Lighting Zone 0 (Unspecified) Construction Site: Owner/Agent: Designer/Contractor: 731 E DURANT#7 ASPEN, Colorado 81611 Allowed Exterior Lighting Power A B C D E Area/Surface Category Quantity Allowed Tradable Allowed Watts Watts / Wattage (B X C) Total Tradable Watts (a) = 0 Total Allowed Watts = 0 Total Allowed Supplemental Watts (b) = 350 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 350 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power Exterior Lighting TBD: Exterior lighting zone not specified (see project screen) Project Title: RenterglYf I) Data filename: e/163ik 072 3 ASPEN BUILDING DEPARTMENT COMcheck Software Version COMcheckWeb (ICI Mechanical Compliance Certificate Project Information Energy Code: 2021 IECC Project Title: Location: Aspen, Colorado Climate Zone: 7 Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 731 E DURANT#7 ASPEN, Colorado 81611 Mechanical Systems List Quantity System Type & Description Mechanical Compliance Statement Compliance Statement: The proposed mechanical alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 2021 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name-Title Signature Date Project Title: Rentt=: EIVf/ D Data filename: tie/3.dik 072 3 ASPEN BUILDING DEPARTMENT COMcheck Software Version COMcheckWeb ril Inspection Checklist Energy Code: 2021 IECC Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Req.ID C405.6 Group R-2 dwelling units have EComplies [PR16]1 separate electrical meters. Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) p � FilY11"` Project Title: Re :'1 t te: Data filename: o 165/f2O723 ASPEN BUILDING DEPARTMENT Section # Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID C405.7 :Low-voltage dry-type distribution ❑Complies [EL26]2 'electric transformers meet the ❑Does Not minimum efficiency requirements of ❑Not Observable Table C405.6. ❑Not Applicable 1 C405.8 :Electric motors meet the minimum ❑Complies 1 [EL27]2 efficiency requirements of Tables ❑Does Not C405.7(1)through C405.7(4). ❑Not Observable Efficiency verified through certification under an approved certification ❑Not Applicable program or the equipment efficiency ratings shall be provided by motor manufacturer(where certification programs do not exist). C405.9.1, Escalators and moving walks comply ❑Complies C405.9.2 with ASME A17.1/CSA B44 and have ❑Does Not [EL28]z automatic controls configured to reduce speed to the minimum ❑Not Observable permitted speed in accordance with ❑Not Applicable ASME A17.1/CSA B44 or applicable local code when not conveying passengers. C405.10 Total voltage drop across the ❑Complies [EL29]2 combination of feeders and branch ❑Does Not ;circuits <= 5%. ❑Not Observable j ❑Not Applicable C405.1.1 ;At least 90%of dwelling unit ❑Complies [EL3O]z permanently installed lighting shall ❑Does Not have lamp efficacy>= 65 Im/W or :luminaires with efficacy >= 45 Im/W ['Not Observable or comply with C405.2.4 or C405.3. Observable,__, Applicable C405.11, :50%of 15/20 amp receptacles ❑Complies C405.11.1'installed in enclosed offices, ❑Does Not [EL31]2 conference rooms, copy rooms, break rooms, classrooms and workstations ❑Not Observable and > 25%of branch circuit feeders ❑Not Applicable for modular furniture will have automatic receptacle control in accordance with C405.11.1. Additional Comments/Assumptions: r--3. High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) cF/I6f d Project Title: Re ol Erpp te: UL Data filename: V147kO723 ASPEN BUILDING DEPARTMENT Section # Final Inspection Complies? Comments/Assumptions & Req.ID C408.1.1 Building operations and maintenance ❑Complies [F157]1 documents will be provided to the ❑Does Not owner. Documents will cover manufacturers' information, ['Not Observable specifications, programming ❑Not Applicable 1 procedures and means of illustrating 1 to owner how building, equipment and systems are intended to be installed, I maintained, and operated. 1 Additional Comments/Assumptions: High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) glYf Project Title: Re ol Er te: Data filename: 6171677f2O723 ASPEN BUILDING DEPARTMENT