Loading...
HomeMy WebLinkAboutFile Documents.731 E Durant Ave.0031-2023-BRES (15) 411)1.1:1:: THE CITY OF ASPEN it of and Pitkin County Y Aspen p FIREPLACE & WOODSTOVE REGISTRATION *Parcel Id number:2 7 3 7 -- 7 1 8 -- 2 1 -- 0 4 5 Street Address:731 E DURANT STREET#7, ASPEN COLORADO,81611 Owners Name: ARTHUR DAY *Required—Contact Assessors offices at 920-5160 Registration will not be accepted without a Parcel Id number List all devices in your home (2 are allowed per building, except for gas appliances) Note:If the number, type and location on this registration form do not match what is show on your plans or what is actually installed,your permit or Certificate of Occupancy will be denied. Type of Building (circle one): Residential Other Type of device Room Existing New Make & Model Wood burning fireplace (select one) LIVING ROOM YES ?Site-built masonry ?Factory built insert: model number: Gas log fireplace (select one) ?Site-built masonry ?Factory built insert: model number: Certified woodstove Gas fireplace appliance LIVING ROOM (attach spec sheet) YES URBANA U50 If any , . « • WOOD BURNING FIREPLACE WILL BE REPLACED WITH A GAS FIREPLACE INSERT 2p23 031311 � 01/20/2023 Signature of applicant Date RECEIVED G:\city\building_dept\Aspen 2004 Checklists\fireplace registration .doc 0 2/16/2 0 2 3 over ASPEN BUILDING DEPARTMENT ASPEN/PITKIN COUNTY FIREPLACE AND WOODSTOVE REGULATIONS In order to keep our air as clean as possible,the elected officials of Aspen and Pitkin County have passed ordinances to regulate the number of fireplaces and woodstoves that can be installed in any building. Building permit applicants must file a fireplace/woodstove registration with the City of Aspen Building Department or the Pitkin County Building Department before the building permit is issued. Pitkin County is separated into 2 areas. One is the non attainment area,which includes the City of Aspen and the Metropolitan areas of the county,i.e.Mountain Valley,Red Mountain,Difficult Campground,T Lazy 7 Ranch,and part of Starwood. The other is the attainment area which includes the less densely populated parts of the county,i.e.Brush Creek Village,Holland Hills and Old Snowmass. Decorative gas appliance:A device utilizing natural gas as a fuel gas designed to appear as a real fireplace with a 4 to 5 inch Class B vent or direct vent,fixed glass door and a firebox no deeper than 24 inches. Certified Woodstove: Colorado Phase III certified woodstove or a Phase II EPA certified woodstove. Gas log fireplace:Meet all codes for burning wood but are used with gas logs. They are not allowed in bedrooms. Aspen and Metropolitan Areas of Pitkin County in the non attainment area New buildings in the non attainment area may have either 2 gas log fireplace or 2 certified woodstoves or 1 each. They may also have an unlimited number of decorative gas appliances. Wood burning fireplaces cannot be installed,nor may coal be used as fuel. Remodeling or an addition to an existing home in the non attainment area • If the building has 2 or more fireplaces,gas log fireplaces or woodstoves,they only devices you can add are decorative gas appliances. • If the building has 1 fireplace,gas log fireplace or woodstove,you may add 1 gas log fireplace and an unlimited number of decorative gas appliances. • If a building has more than 2 fireplaces,gas log fireplaces;if one is affected by the remodel it must be removed. • If a building has only 1 or 2 fireplaces,woodstoves or gas log fireplaces,please keep in mind: o If you alter the firebox of a fireplace,it must be converted to gas logs or removed. o If a woodstove is moved,it must be removed or replaced with a department certified woodstove. Attainment Area in Pitkin County New residential buildings in this area may have one wood burning fireplace and one gas log or certified woodstove. If there is no fireplace,you may have either 2 gas log fireplaces or 2 certified woodstoves or 1 each. Buildings may also have an unlimited number of decorative gas appliances. Remodeling or an addition to an existing building in the attainment areas • If the building has 2 or more fireplaces or woodstoves,the only devices you can add are decorative gas appliances. • If you have 1 fireplace or woodstove,you may add 1 gas log or certified woodstove and an unlimited number of decorative gas appliances • If a building has more than 2 fireplaces or woodstoves: if one is affected by a remodel,it must be removed • If a building has on 1 or 2 fireplaces,woodstoves or gas log appliances,please keep in mind: o If a woodstove is moved,it must be removed or replaced with a department certified device. o If you alter the firebox of a fireplace,and already have another fireplace,it must be converted to gas log Non residential buildngs(which include commercial buildings,restaurants,lodges,public buildings,and hotels)in the attainment area of Pitkin County are allowed to have gas appliances. RECEIVED G:\city\building_dept\Aspen 2004 Checklists\fireplace registration .doc 0 2/16/2 0 2 3 over ASPEN BUILDING DEPARTMENT mOnTlc7O® SPEC II SHEET MONTIGO/DIVINE/H38CRNI-2/TRADITIONAL LOGSET 1 dill1L.,........7 . . lil IIIIV T r: . - -1:� ' ' , ems- N., . _- \ s7,14.., a . . . irikir, - ,t_,. SPECIFICATIONS w H I l MULTI lit SIDED A \ D FEATURES DIVINE CL/CR DIVINE CL/CR CONTEMPORARY TRADITIONAL Standard Standard I-I 3 8 C L/C R ,e' � Contemporary burner with Traditional burner Ice fireglass and logset Remote Hi-Lo flame control Heritage brick liner - Multi-function Wrought iron grate remote control Remote Hi-Lo flame control , Battery backup Corner Multi-function remote control Direct vent Options Battery backup Glass media Wall remote Options QUICK DIMENSIONS Wall remote H38CL/CR UNIT FRAM. F.WIDTH 439/16 42 B.WIDTH 281/6 42 HEIGHT 415/16 461/2 DEPTH 206/6 215/6 VIEWING 39Yx28'/a RECEIVE( BTU LISTING EFFICIENCY H38C*NI-2/34,000 BTU HL38C*NI-2/34,000 BTU H38C*NI-2/FE 58.5 HL38C*NI-2/FE 58.5 0 2/16/2 0 2 3 H38C*LI-2/32,000 BTU HL38C*LI-2/32,000 BTU H38C*LI-2/FE 58.5 HL38C*LI-2/FE 58.5 ASPEN BUILDING DEPARTMENT DIVINE CL/CR DIMENSIONS G 1~ i I -• 0- H f � 1 r N. }_ K A w . ... -z--1---- I 1 II• 'I 1 11 _11 F0 fi � C E L •‘!-.•.'. .7_. , . „, .- .-„,;,.. • 4 'R _j� "`- ,diL�' .7u z TM 1 1. B —.1 H K �—N—' willow, A BCDEF G H I J K LMN - H38C* 393/16 423/16 395/8 4 2413/16 6 203/8 7 241/4 253/8 221/4 331/4 37/16 143/16 r- ■ N a Q co �1 K Li rn Z 0 c#4 ' ktlit - i----' . •- 1 •� 23 kY3I31I2p 00016-- y- °Standard on all corner units RECEI\/ED w Vvo. - rStandard on H38C"I-2 z0� �, Ia 02/16/2023 0LL- MOTE HERITAGEt RX200** REC1493 ASPEN BUILDING DEPARTMENT Unit Icon Legend AVAILABLE + NOT AVAILABLE - S o o c i f i c at i o n s DEDICATED 0 STANDARD ° PIER FRAMING BAY FRAMING CORNER FRAMING -EE THROUGH FRAMING O 48" 0 0 O‘ I -- I j. -<_ 40a/a" _ I J B 233/4" i 44" C 44" 44" 433/4" 41" 251/4" . - y / 24,/z" ,•/ NON COMBUSTIBLE STUD INCLUDED - A WITH UNIT ,/ Approximate dimensions to center.For best results mount noncombustible stud onto unit, A BCD then bolt to 2x4 header and floor. 38F5D 403/4" 421/2" N/A 233/4" H42FSD 45" 491/2" 461/2" 24" NON COMBUSTIBLE STUD INCLUDED WITH UNIT-NOT NEEDED FOR H38FSD c c a a a cc H v a a) co t7 a a a' v ° 01 ° CO 1a o c Y a c S 70 H H in m LL E s o rn .— N 0 7 V V V v V N io -O V L —. o of c c c c c °1 > ai '— a' z = c ro ro ro ro CO 5 rn E s v o rn I- I- aci v at6, CO (I) O.1 C C y > o v n, a o co co > U U U U U LL u_ VI d cc LL D in H38FSD* 34,000 32,000 5'%8" 9 171 1 2 0 35344x263/8 Tempered Traditional ° + + + - - H38FSD*I 34,000 32,000 578" 9 171/2 1 2 0 353/4x263/8 Tempered Traditional 0 + + + - - H42FSD* 37,000 37,000 578" 9 171/2 1 2 0 393/8x303/8 Tempered Traditional ° + + + - - H42FSD*I 37,000 37,000 578" 9 171 1 1 0 393/8x303/8 Tempered Traditional ° + + + - - H38PF*1-2 34,000 32,000 578" 9 171/2 1 1 0 321/8x215/8 Tempered Traditional 0 + 0 - - - } Ili HL38PF*I-2 34,000 32,000 5'%8" 9 171/2 1 1 0 321/8x215/8 Tempered HW1157 + � 23� H38PR*I-2 34,000 32,000 5"/8" 9 171/2 1 1 0 321/8x24% Tempered Traditional ° + ° 1� '3 2 HL38PR*I-2 34,000 32,000 5"/8" 9 171/2 1 1 0 321/8x243A Tempered HW1157 ° + ° \lrlit, coot— mi H38CL*I-2 34,000 32,000 5"/8" 9 171/2 1 1 0 321/8x243/a Tempered Traditional + 0 - Sa HL38CL*I-2 34,000 32,000 5"/8" 9 171/2 1 1 0 321/8x24% Tempered HW1157 ° + ° - - - H38CR*1-2 34,000 32,000 5"/8" 9 171/2 1 1 0 321/8x243A Tempered Traditional ° + ° RE ' EI'iED HL38CR*I-2 34,000 32,000 5"/8" 9 171/2 1 1 0 321/sx243A Tempered HW1157 ° + 02/16/2023 ASPEN BUILDING DEPARTMENT BRAN® Under-Cabinet GLACIER The clean,contemporary shape of Glacier complements any kitchen design.Impressive LED lighting and superior smoke and odor removal are a mere introduction to everything this hood has to offer.The LED modules included with this hood are the latest in LED cooktop illumination technology specially designed to operate in the elevated temperatures of cooking-offering bright lighting and lasting up to 25 times as long as a standard bulb and greater reliability than typical replacement LED bulbs. BCDF13OSS SIZE BLACK STAINLESS GREASE FILTERS NON-DUCTED STAINLESS (replacement) FILTERS 30 in. BCDF130BLS t BCDF130SS HPFAMM30(Type"C2") HPF30(Type"Xc") C el US 36 in. BCDF136BLS t BCDF136SS t HPFAMM36(Type"D2") HPF36(Type"Xd") 42 in. BCDF142SS t HPFAMM42(Type "E2") HPF42(Type"Xe") t Not available in Canada. HVI PERFORMANCE ALL OTHER Sones CFM HOODS Duct Orientation Size Damper High High Normal Medium* High Normal Medium* 0.25 in.w.g. 0.1 in.w.g. J Vertical-Rectangular 31/4 in.x 10 in. Included 1.5 3.0 6.0 130 170 150 240 Horizontal Rectangular 3Ya in.x 10 in. Included 1.5 3.0 6.0 110 160 160 240 Round-Vertical 7 in. Sold Separately 2.0 3.0 5.5 140 190 115 260 FEATURES ® 2100 M, Max. Blower CFM" 375 CFM V' Control type 3-speed Capacitive Touch CERTIFIED Delay off no m _ Filter Clean Reminder yes I 20 SentryTM s"r�i���c�� is �i':, 4p co A Heat Sentry no �5 S� i`A (VA ti: gwtvmte a� %-- c�r�ic iu4tt:i.e 24 f ADA Capable yes _ ' <r<4<<<"�`.il,`"�u d`J.. ... r:• _NM 4 Lighting 2-level LED(included) , y �`d54'."j ` , y Ramp Grease Filters Micro Mesh(Qty. 2) �, '` . +t^'`" Installation Hardware EZ1 brackets l,. ', �ENERGY STAR® no I ' 1 Recirculation Non-ducted filters sold separately r.-- ACINPUT '''I � . � 1 20 V,60 Hz-0.65 AMPS _._-� III; i— .-..r^ OPTIONAL ACCESSORIES 1 I 7-in. Round Damper BP87Q Make-up Air Dampers MD6TU, MD8TU and MD1OTU ADA Wiring Kit HAWRK3 MOUNTING HEIGHT �.t> db.-iv Cl) 18 in.to 24 in. from cooktop to bottom of hood ��� `b-�� y�'� �, .--", � sue` �% �''1. W LIMITED WARRANTY `b'm � 0� 3 G 1-year fie. 13 2 W 3-year(LED modules only) %8 (See installation manual for full warranty text.) -:'','.x. U) FOR INDOOR USE ONLY '( 5 r.d Al8 0.6 .II —Vertical High Speed, AiA.rr 1 3 8 IML 0.5 _ 7-in.round - I9 0 29 g' Dimensions 04 • —Vertical High speed, 8 shown in inches. with 3'/<in.x 10 in.damper �✓ 0.3 —Horizontal High Speed, - with 3Y.in.x10 in.damper 0.2 I— •L IS W I '0.1 2 N CC o i z 0 50 100 150 200 250 300 350 400 CDAirflow(cfm) CEIVED HVI-2100 CERTIFIED RATINGS complywith new technolo ies and rocedures the Home Institute,for off-the-shelf roducts,as testing 9 P prescribedby Ventilating P QCD they are available to consumers.Product performance is rated at 0.1 in.static pressure,based on tests conducted in AMCA's state-of-the-art test laboratory.Son U are a measure of humanly-perceived loudness,based on laboratory measurements. LL a "Where noted performance rating is not HVI certified but was established in accordance with HVI Standardized test procedure. C) ""Max.blower CFM indicates the performance of the hood blower in open air. 0 2 2 3 Broan-NuTone LLC I 926 West State Street, Hartford,WI 53027 I 1 800-558-1711 I www.broan-NuTone.com C/J Venmar Ventilation ULC 1550 Lemire Blvd., Drummondville,Quebec Canada J2C 7W9 I 1 877-896-1119 I www.nuA. J 1-"L BUILDING DEPARTMENT B R ® Hottes conventionnelles GLACIER La forme simple et contemporaine de Glacier convient a tous les styles de cuisine. L'eclairage DEL impressionnant et l'elimination superieure de la vapeur et des odeurs de cuisson ne sont qu'un avant-goat de tout ce que cette hotte a a offrir Les modules DEL etant issus de la plus recente technologie en matiere d'eclairage de surface de cuisson, ils sont specialement congus pour fonctionner dans un environnement a chaleur elevee. Leur durabilite est jusqu'a 25 fois superieure a celle des ampoules standards et ils sont plus robustes que les ampoules a DEL typiques. BCDF130SS FILTRES A GRAISSES FILTRES DE LARGEUR INOX NOIR INOX (remplacement) RECIRCULATION 30 po BCDF130BLS t BCDF130SS HPFAMM30(Type"C2") HPF30(Type"Xc") t Non offert au C 411) US 36 po BCDF136BLS t BCDF136SS t HPFAMM36(Type"D2") HPF36(Type"Xd") Canada. 42 po BCDF142SS t HPFAMM42(Type"E2") HPF42(Type"Xe") RENDEMENT HVI TOUTES LES Sones pia/min AUTRES HOTTES Orientation du conduit Largeur Volet Haute Haute Normale Moyenne* Haute Normale Moyenne* 0,25 po d'eau 0,1 po d'eau CO Rectangulaire vertical 3/pox 10 po inclus 1,5 3,0 6,0 130 170 150 240 Rectangulaire horizontal 3'/a pox 10 po inclus 1,5 3,0 6,0 110 160 160 240 Rond vertical 7 po vendu separement 2,0 3,0 5,5 140 190 115 260 CARACTERISTIQUES I ® 2100 M, Puissance max.du ventilateur" 375 pia/min FIV' Type de commande Capacitive, a 3 vitesses CERTIFIED Arret differe non Rappel d'entretien des filtres oui ; 4, cc,,g Detecteur Heat Sentrymc non ! � �1 s 24 = Capacite ADA oui PANT* Eclairage DEL a 2 intensites(inclus) = ,., , ,„ Filtres a graisses A maillage fin(qte 2) J/ Materielpour('installation Supports EZ1 /� , .:,.:,,,,, ..,.„ l ' ,__. , Peut titre utilise pP pour se conformer ENERGY STAR® non ;' 41111 Q 1 "° aux exigences du 2019 Title 24 Recirculation Filtres de recirculation vendus sesarement 4 ' ' _,. `"" _ Part6pourhottes ALIMENTATION CA -..- �— de cuisinieres. 120 V, 60 Hz 0,65 A 1� IIME°�.AR ACCESSOIRES OPTIONNELS ,fir" s Volet rond de 7 po BP870 I Dispositifs d'apport d'air MD6TU, MDBTU et MD1OTU Ensemble de cablage ADA HAWRK3 HAUTEUR DE MONTAGE �% �.R, De 18 po a 24 po au-dessus de la surface de cuisson �ti%� _h'cz., ��.m r GARANTIE LIMITEE �`4-zea .��ea oc,� `� �'R. 1 an / 3 al 3 ans(modules DEL seulement) ~�` 8 2 C..) (v'oir le manuel d'installation pour le texte complet de la garantie.) Z% ._v CO POUR UTILISATION A L'INTERIEUR SEULEMENT �/ 6 1 0,6 33 6 61 �'Ia W —Vertical 7 po rond, 13 8 r ,- 0,5 — — haute vitesse Its 5 pQ ' Les dimensions a —Vertical rectangulaire �`77 8 `✓8 indiquees sont n 44 3'/.pox 10 po,haute vitesse" \�►✓/ W en pouces. o 0 3 - —Horizontal rectangulaire , 3%pox 10 po,haute vitesse g 0,2 a 0,1 W o C5 ■ 0 50 100 150 200 250 300 350 400 z W Debit de rair(pi'/min) _ C + L'HOMOLOGATION HVI-2100 est conforme aux nouvelles techniques et procedures d'essai prescrites par le Home Ventilating Institute pour les produits d'emploi couraD FC E I\1E D CD Cm) des leur disponibilite pour les consommateurs.Le rendement du produit est evalue a une pression statique de 0,1 po,d'apres les tests effectues dans le laboratoire d'es i W I— ICC ultra-perfectionne de I'AMCA.Le sone est une mesure de la perception humaine de la puissance sonore,d'apres des mesures effectuees en laboratoire. Signifie que la donnee n'est pas certifiee par le HVI,mais a ete obtenue suivant les procedures de test standardisees du HVI. ppQ � _ "La puissance maximum du ventilateur indique la performance du ventilateur de la hotte a lair libre. 0 2 r itC 2 3 CDBroan-NuTone LLC 1926 West State Street, Hartford,WI 53027 I 1 800 558-1711 I www. roan- uTone.com li Venmar Ventilation ULC 1550 boul. Lemire, Drummondville,Quebec Canada J2C 7W9 I 1 877 896-1119 I www.nuAto .N J1"L BUILDING DEPARTMENT