Loading...
HomeMy WebLinkAboutFile Documents.904 E Cooper Ave.0039-2022-BRES (11) APPLICATION ACCEPTED DATE- _1:22 U4 06 PERMIT NUMBER: 0039-2022-BRES Field Plan Set Must Be Printed In Color ��►►;� � CITY OF ASPEN %r 2 2 COMMUNITY DEVELOPMENT DEPARTMENT ���q�/0 PERMIT NO. Ar 0039-2022-BRCS IdI PRINCESS POW LLC CITY OF BUILDING PERMIT COVERSHEET OWNER CITY OFASPEN ASPEN ADDRESS 904 E COOPER AVE PROPERTY INFORMATION PARCEL ID 273718231046 These plans muus eKeept at the ADDRESS. 904 E COOPER AVE UNIT: building site or inspection PARCEL ID: 273718231046 LEGAL DESCRIPTION: 904 E COOPER/312 WEST END delays may occur.Construction OWNER'. PRINCESS POW LLC shall conform to these plans.All PERMIT CONTRACTOR: HENDRICKSON CONSTRUCTION INC changes shall be approved 75%of lamps in permanently REFERENCES FROM 2015 IRIfilig C g pp by r installed light fixtures shall be CV/A=crawl space ventilation required,sec.R408.1 Access required,R408.4 ing official. high efficacy-IECC R404.1 EE=emergency escape required sec R310.1 EU=enclosed usable space under stairs shall be'4/:"Gyp,sec R302.7 G/D=garage/dwelling separation,sec R302.5 and R302.6 DESCRIPTION OF WORK Full interiorre-model onunit 2 and existingADU.All new fixtures and finishes.New main stairdesign.Newfront FIRE RATED HATS REQUIRED STC=Sound transmission class not less than 45 at dwelling separations,app SEPARATE PERMITS ARE door.New ADU stair railing. Where floor/ceiling or roof/ceiling K assemblies are required to have a RV=roof and rafter ventilation required,R806.1 REQUIRED FOR ELECTRICAL, fire-resistive rating,recessed fixtures shall A=attic access 22"x 30",30"headroom above,R807.1 PLUMBING,MECHANICAL,OR be installed such that the required fire SA=smoke alarms installed to NFPA 72 requirements,sec R314 FIRE SPRINKLER WORK resistance will not be reduced(IBC 714.4.2) CO=carbon monoxide detector per City Ordinance 41 series 2008 SG=safety glazing required,sec R308.4 SMOKE ALARMS AND USE OF BUILDING Multi-Family FIRE SPRINKLER REQUIRED? Yes GR=guardrails,36"min ht,4"max opening;req at 30"drop any point w/in 36" CEILING RADIATION DAMPERS REQUIRED horizontally,sec R312 CARBON MONOXIDE Ducts and air transfer openings penetrating the ceiling of WFP=window fall protection-operable window<24"AFF&>72"above DETECTORS REQUIRED a fire rated ceiling assembly must be protected with a grade:use opening control device listed to ASTM F2090,sec R312.2 THROUGHOUT DWELLING listed ceiling radiation damper.This includes bathroom HR=handrails 34"-38"ht,sec R311.7.8 CLASS OF WORK Residential FIRE SPRINKLER TYPE NFPA 13 exhaust fans.(IBC 717.6.2) SI=stairway illumination,sec R303.7 UNIT PER CITY OF ASPEN PD=protect against decay,sec R317 MUNICIPAL CODE 8.15 REFERENCES FROM 2015 IMC REQUIRED SPECIAL V bathroom and 40, an balanced whole house mechanical ventilation req. BUILDING TYPE(IRC) Townhouse Ordinance INSPECTIONS DE=clothes dryer exhaust,sec 504.Makeup air req'd if over 200 CFM ELECTRICAL/LIGHTING LEGEND AS=access and service space for maintenance req'd,sec 306 It should be known that this review shall Lower level ADU and ceiling assemblies MA=make up air required if hood exhausts greater than 400 CFM,sec akes, .2 not relieve the applicant Of their CONSTRUCTION TYPE VB ENERGYCODE COMPLIANCE Qp DUPLEX ET=exhausts terminate 3'from prop line and openings,10'from intakes, 501.3.1 responsibility to comply with the * SWITCHED OUTLET aril IT=intake openings 10'from lot line&contaminant sources(vents,streets), requirements of the City of Aspen ( ) WORK CHANGES BUILDING `' SWITCHED FLOOR OUTLET G�� ° 401.4 Municipal Code.Pursuant to OCCUPANCY GROUP IBC No K D=fasten and seal all ductwork per 603.9 FOOTPRINT? REFERENCES FROM 20151FGC Sec.26.104.050,any permit or approval -0 CLOCK OUTLET - DV=direct vent req'd,sec 303.3 issued in error or otherwise not in 2 W W CA=combustion air not taken from bedrooms,bathrooms or conformity with the requirements of this CODE EDITIONS 20151RC TOTAL SPA SQ.FT. $ SINGLE POLE SWITCH -? storage sec 303.3 Title,shall be void.Similarly,any permit f3 THREE WAY SWITCH o m o _ OD=outdoor appliances must be listed for outdoor use,sec 303.6 or approval issued in reliance upon or Fe g E M W W REFERENCES FROM 2015 IECC f4 1HREE WAY SWITCH a g�< as a result of,a materially false o °0 3 O F=new or replacement glazing shall not exceed 0.28 U-Value,NFRC label :« °a statement or representation made in OTHER CODE EDITIONS TOTAL SNOWMELT SQ.F T. fT TMERswmcn -°a'a L'o4 required,Ordinance 40,2016 u=in o,; Si« L=75%of lamps in permanently installed lights must be high efficacy,sec the process of obtaining the permit or f" TOEKIcxswlTCH u ,°a v, OR go R404.1 development approval shall,likewise, fJ JAMB SWITCH a a i m 0 10 0 o g u SE=Continuous air barrier required;all exterior joints,cracks,and holes to b be void.Any person having received a _ m ft W - caulked,gasketed,sealed,table R402.4.1.1 void or voidable HISTORIC PROPERTY? No TOTAL POOL SQ.FT. SWITCH CIRCUIT a a a n W o �opermit or approval REFERENCES FROM 2014not NEC shall not be relieved from having to �L TRACK LIGHTING o EP=electric panel'happy space'30"x36"x78",not in storage,sec 110.26 g comply with all applicable terms and erloiC Floor/Gelling l hour Bre,STC S3 assembNfrom the Gypsum Manual(GA-WO Fire B vo e 9 conditions of this Title and the City shall FIRE SPRINKLER EXISTING? Yes Resistance lDesign Manual): nmemss INTFocTURE _ X $ not be estopped from fully enforcing (No IIG given.Must use an underlavment product or carpet to achieve IIC 50) * RECESSED 3 LED CAN,ADJUSTABLELI$wG _ OQ m GA FILE NO.FC 20 I I I > E IY°ae E same. w000 .....a I Flv R I !Cure RECESSED 3'LED CAN,ADJUSTABLE.RATED 8 O z w m O o,z _�i FORWET LOCATION WwIrv'vU o UN'O�'m �- RECESSED 3'WALL WASH w CAN i w uj m N E1 ,-o 2 O Entire lower level ceiling assembly is a 1 hour fire rated floor/ceiling J<°<w °_ <owa � RECESSED LED IN CABINETRY Q o.E assembly for proper continuity of the ADU dwelling separation. - . ,�„_,•e O CEILING MOUNTED PENDANTre:re Anywhere 32 sq.ft.of drywall is disturbed listed assemblies shall be put • „" LEILIrvGMDDN EDLLDSETFI TDRE ,back in place. Within the ADU FC5120 shall be used for a compliant ICJ CEILING LED FIXTURE 31/2022 dwelling separation(1 hour fire and STC 45 or greater). Within the main Na. RMbeMd. ZONING unit side of the lower level FC5406 may be used to avoid a resilient CEILING MOUNTED FIXTURE channel as long as you transition assemblies at a double top plate(fire L tiu��.-» """ I� WALL MOUNTED FIXTURE W rated assemblies may be interrupted by double top plates). SubmitGEER* ••-ILir, LED UNDEecABINET,TOE KICK X NICHE FIXTURE W revised assemblies if existing conditions differ. ���� (( STEP LIGHT U Q pomp_ o EXHAUSTFAN W 'l MIMI 0 CARBON MONOXIDE DETECTOR Q t� W LANDINGARNE '�I ® SMOKE DETECTOR Q LL ..... 4 THHERMKOST TLER EAD W N o C.) /L`L/ () rill-EN-tail 24/2022�IVI ^s%Or lampsiRUreSSheRuy ��.ftli a PANEL BOX } I- Z FORC,y,.:� stalled light iMures shall be �/ GA FILE NO.FC uas GENERIC 4xOUR 33 to 3g sic high erOcacy-IECC R404.1 �� - = Y Z y W linZhid TELEPHONE /A Li WOOD JOISTS,GYPSUM WALLBOARD FIRE SOUND =''''' �iii ''�, V! °'oc '°" �� NERNET W Q W a d ° a wRNGCK o 03 en N,na Mnatme.e Z III IM;11�■ GARAGE IooDRDPENER ee ruwrc t,z zz BATH#2,1� ■ e 11 • a Pound Test 5exmeba III O # ^ r+BACKLITL+ TIE NEW EXHAUST FAN INTO MIRRORO EXISTING DUCTWORK ELLIES BEDROOM Q B 1101 NOTES-LIGHTING/ELECTRICAL — + ^-- ^— ■ I • ALL NEW DEVICES AND SWITCHES DRAWN BY:ANNE GRICE INTERIORS • ADD OUTLETS PER COPE FIRE RATED HATS REQUIRED haven ED II o • ALL SWITCHES To BE ON DIMMERS PERMIT SET ceiling or roof/ceiling 8,�. - d fixtures • W"semhlesarerg,recdtahavea a CODE 02-16-2022 rbesisianlCee Wilfil l niott be redch that Meuced(IBC 7t44.21 • CLOSET LIGHT FIXTURE INSTALLED PER uired fire CONSTRUCTION DOCUMENTS El + -' ALL CANS TOBE IC/FIRE RATED•FIRE HATS ISSUE DATE: CEILING RADIATION DAMPERS REQUIRED Ts Si RCM FOR ALL Tv s a COMP ONENT s Ducts a. 01/27/2022 CONTRACTOR REVIEW'lina openings penetrating the caidng of E I+a fire listed DESIGNER ADU BATH E _ I, * A.D.U. • ALL FIXTURES OBE LED 8-0' I _ qa- • ALL FIXTURES TO MEET IEC INSTALLED IN PERMANENT LIGHT mE NEW TINGEXHAUST DUCTWORK I + * • ALLI Evpucr u5 BUR l INTOEXISTINGDULTWORK UNITS IECC R4404.1). FANS TO TIE INTO EXISTING lMinli BACKLIT MIRRORS -Ina � krillI SHEET TITLE: 'THIS UNIT HAS EXISTING SPRINKLER SYSTEM LIGHTING/ELECTRICAL 'THIS UNIT HAS SPLIT-UNIT NC UNITS EXISTING/DEMOLITION& •IN FLOOR RADIANT HEAT GRAPHIC SCALE,iv'-1,-0. PROPOSED PLANS 'NO CHANGES TO HVAC -LOWER LEVEL A LIGHTING/ELECTRICAL PROPOSED PLAN-LOWER LEVEL �q � SHEET: 1031 SCALE: 1l4"=1'0" �D Mee U PLAN s kevoI f%t�'Lfa P) 'D3.1 p8/24/2022 J NORTH sophiev U -CEI\ICL1 QS/27/2022 J G YCV FORCOlx lifFE lKd s ZONING 03/29/2022 nhi ASPEN OUILDINGDEPNUMENT