HomeMy WebLinkAboutFile Documents.300 S Spring St.0054-2021-BCHO0054-2021-BCHO_300 S Spring 200_BuildingComment1 Subject: PlanCheck Page: [2] 20067-e-e2.0 Author: justinh Color: File Name: 90.300 Spring.CO1 Sheets.20210816.pdf If you use the space by space lighting power allowances you need to break the office up into the relevant spaces (office, restroom, etc.), otherwise you should be using the building area method which has offices at .82 W/sq.ft. I only measure 780 sq.ft. of interior office space per the drawings. 90.300 Spring.CO1 Sheets.20210816.pdf (6) Subject: PlanCheck Page: [2] 20067-e-e2.0 Author: justinh Color: File Name: 90.300 Spring.CO1 Sheets.20210816.pdf The open/common office space is required to be provided with either a time switch control switch or occupancy sensor per IECC 405.2.2. Note how you will be providing compliant controls for the main space. Subject: PlanCheck Page: [2] 20067-e-e2.0 Author: justinh Color: File Name: 90.300 Spring.CO1 Sheets.20210816.pdf Use the driver/transformer wattage for your strip light as required by IECC C405.4.1 Subject: PlanCheck Page: 1 Author: justinh Color: File Name: 90.300 Spring.CO1 Sheets.20210816.pdf I only measure 780 sq.ft. of interior gross area, which would be 8 occupants. Revise the occupant load calculation. Subject: PlanCheck Page: 1 Author: justinh Color: File Name: 90.300 Spring.CO1 Sheets.20210816.pdf 2020 NEC is our currently adopted electrical code, please revise. OFFICE201CARPET (E) (E) A A A A D V If you use the space by space lighting power allowances you need to break the office up into the relevant spaces (office, restroom, etc.), otherwise you should be using the building area method which has offices at .82 W/sq.ft. I only measure 780 sq.ft. of interior office space per the drawings. OFFICE 201 CARPET A A A A The open/common office space is required to be provided with either a time switch control switch or occupancy sensor per IECC 405.2.2. Note how you will be providing compliant controls for the main space. A A A A Use the driver/transformer wattage for your strip light as required by IECC C405.4.1 CODE JURISDICTION: 2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL PLUMBING CODE 2015 INTERNATIONAL MECHANICAL CODE 2015 INTERNATIONAL FUEL GAS CODE 2015 INTERNATIONAL FIRE CODE 2017 NATIONAL ELECTRIC CODE OCCUPANCY (EXISTING TO REMAIN): BUSINESS (B) = 838 SF OCCUPANT LOAD: BUSINESS = 100 GROSS 838 SF / 100 = 9 OCCUPANTS CONSTRUCTION TYPE (EXISTING): CONSTRUCTION TYPE V-B FIRE RESISTANCE RATING REQUIREMENTS: CONSTRUCTION TYPE V-B STRUCTURAL FRAME: NR BEARING WALLS, EXTERIOR: NR BEARING WALLS, INTERIOR: NR NON-BEARING WALLS, EXTERIOR: NR NON-BEARING WALLS, INTERIOR: NR FLOOR CONSTRUCTION: NR ROOF CONSTRUCTION: NR BUILDING CODE ANALYS BUILDING HEIGHT AND AREA : EXISTING TO REMAIN EXIT ACCESS TRAVEL DISTANCE: GROUP B OCCUPANCY: 300' MAX (21'-6" PROVIDED DEAD END CORRIDOR: I only measure 780 sq.ft. of interior gross area, which would be 8 occupants. Revise the occupant load calculation. CODE JURISDICTION: 2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL PLUMBING CODE 2015 INTERNATIONAL MECHANICAL CODE 2015 INTERNATIONAL FUEL GAS CODE 2015 INTERNATIONAL FIRE CODE 2017 NATIONAL ELECTRIC CODE OCCUPANCY (EXISTING TO REMAIN): BUSINESS (B) = 838 SF OCCUPANT LOAD: BUSINESS = 100 GROSS 838 SF / 100 = 9 OCCUPANTS CONSTRUCTION TYPE (EXISTING): CONSTRUCTION TYPE V-B FIRE RESISTANCE RATING REQUIREMENTS: CONSTRUCTION TYPE V-B STRUCTURAL FRAME: NR BEARING WALLS, EXTERIOR: NR BEARING WALLS, INTERIOR: NR NON-BEARING WALLS, EXTERIOR: NR NON-BEARING WALLS, INTERIOR: NR BUILDING CODE ANALYS 2020 NEC is our currently adopted electrical code, please revise. COMCheck has been updated. Note has been added to place all common place lighting on time clock. Linear Strip has been removed. CCA - OCCUPANT LOAD REVISED CCA - CODE REFERENCE REVISED Subject: PlanCheck Page: 3 Author: justinh Color: File Name: 90.300 Spring.CO1 Sheets.20210816.pdf Electrical plan only shows a single downlight in the restroom. CENTER WALL FIXTURE OVER VANITY ANSI RESTROOM (E) 205 1' - 6"2' - 6"Q EQ 1' - 6" EQ EQ 2' - 0" 2' - 0" Electrical plan only shows a single downlight in the restroom. CCA - LAYOUT REVISED