Loading...
HomeMy WebLinkAboutFile Documents.617 W Bleeker St.0062-2019-BRES0062-2019-BRES_Zoning_1 Page: 1 Checkmark: Unchecked Author: jimp File Name: 1803_PERMIT SET_191115.pdf Please add grid lines to all of your drawings and elevations. 1803_PERMIT SET_191115.pdf (26) Page: 7 Checkmark: Unchecked Author: jimp File Name: 1803_PERMIT SET_191115.pdf Page: 7 Checkmark: Unchecked Author: jimp File Name: 1803_PERMIT SET_191115.pdf Page: 7 Checkmark: Unchecked Author: jimp File Name: 1803_PERMIT SET_191115.pdf Page: 7 Checkmark: Unchecked Author: jimp File Name: 1803_PERMIT SET_191115.pdf Page: 7 Checkmark: Unchecked Author: jimp File Name: 1803_PERMIT SET_191115.pdf Page: 7 Checkmark: Unchecked Author: jimp File Name: 1803_PERMIT SET_191115.pdf Per the sections, the height of the walls from the bottom of floor structure to the floor of the basement is 13' 6". Please adjust this for walls 1, 9, 8, 7, 6, and 14' for wall 5. Adjust your Subgrade FA calcs to match. Drawing Title Date Please add grid lines to all of your drawings and elevations. 9 35 ' - 1 3 / 4 " FT 4' - 7 " FT 5'-0" 19 ' - 6 " 97.92 SQ FT15 ' - 0 " 21.65 SQ FT 3 5' - 1 0 1 / 4 " Per the sections, this exposed wall should be 6' 5 5/8" 1 24'-6" 353.21 SQ FT 14 ' - 5 " 84.42 SQ FT 6' - 1 1 1 1 / 1 6 " This height should be closer to 7' 3" 4' - 5 " 6" 42 FT 0' - 8 1 / 4 " This height should be closer to 10" ISER 8 1 Per the sections, the height of the walls from the bottom of floor structure to the floor of the basement is 13' 6". Please adjust this for walls 1, 9, 8, 7, 6, and 14' for wall 5. Adjust your Subgrade FA calcs to match. Page: 7 Checkmark: Unchecked Author: jimp File Name: 1803_PERMIT SET_191115.pdf Page: 7 Checkmark: Unchecked Author: jimp File Name: 1803_PERMIT SET_191115.pdf Page: 7 Checkmark: Unchecked Author: jimp File Name: 1803_PERMIT SET_191115.pdf Per 26.575.020.D.8, Subgrade Areas, Exterior wall to be measured is the interior wall projected out. Therefore, in essence the "corners" don't get counted. Therefore, Walls 8, 7, 5, 4 will be shorter in length. I have added red lines on the floor plan to show where the end of the walls should be. Page: 7 Checkmark: Unchecked Author: jimp File Name: 1803_PERMIT SET_191115.pdf I believe this window well is a bit taller than shown. Based on the sections, it is at least 11' to the bottom of the structure above, and then the bottom of the well is probably a bit below the bottom of the window for drainage. Please adjust your drawing and recalculate. Page: 8 Checkmark: Unchecked Author: jimp File Name: 1803_PERMIT SET_191115.pdf Per 26.575.020.D.1, General, FA measures all space within the surrounding exterior walls, including the walls themselves. Therefore, please include the square footage of these walls in your totals for this level. Page: 8 Checkmark: Unchecked Author: jimp File Name: 1803_PERMIT SET_191115.pdf Please provide a section through this planter showing that it meets the restrictions within 26.575.020.D.4.e), Decks, in order for this planter to not count towards deck calculations. Page: 10 Checkmark: Unchecked Author: jimp File Name: 1803_PERMIT SET_191115.pdf Please provide some sort of proof that these closet spaces are full height in order for it all to count towards FA. 4 5'-0" R TREAD/7.75" RISER 8 1 Per 26.575.020.D.8, Subgrade Areas, Exterior wall to be measured is the interior wall projected out. Therefore, in essence the "corners" don't get counted. Therefore, Walls 8, 7, 5, 4 will be shorter in length. I have added red lines on the floor plan to show where the end of the walls should be. 1 9 14 ' - 5 " 35'-1 1/2" 506.39 SQ FT 14 ' - 5 " 24'-6" 5 353.21 SQ FT 14 ' - 5 " 84.42 SQ FT I believe this window well is a bit taller than shown. Based on the sections, it is at least 11' to the bottom of the structure above, and then the bottom of the well is probably a bit below the bottom of the window for drainage. Please adjust your drawing and recalculate. LOGGIA 55.81 SQ FT GARAGE 529.38 SQ FT TOTAL 154.38 SQ FT COUNTABLE1319.61 SQ FT INTERIOR SPACE STAIR 53.40 SQ FT PACKAGE ROOM 101 GARAGE 116 MUDROOM 114 DN LAUNDRY ROOM 115 CORRIDOR 104 ENTRY CLOSET 103 POWDER ROOM107 MASTER BATHROOM 108 DOG WASH 7922'MAIN LEVEL 7922'MAIN LEVEL 7921.5' GARAGE UP STAIR:10" TREAD/7.75" RISER STAIR:10.5" TREAD/7.25" RISER STAIR:10" TREAD/7.25" RISER STAIR:10" TREAD/7.75"RISER TOILET 109 CORRIDOR 110 CLOSET 112CLOSET 111 MASTER BEDROOM 113 CORRIDOR 102 CORRIDOR 106 ATRIUM 105 101 2 2 2 2 2 2 2 101 1 11 1 1 1 1 1 1 1 1 1 1 1 102 103 104 106 107 108 105 111 112 113 110 109 102 103 104 105 106 107 108 114 109 7922' MAIN LEVEL 7922' MAIN LEVEL UP ELEVATOR GENERAL CONTRACTORJanckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc.386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNERHines Inc. 323 West Drake Road #204 Fort Collins, CO 80526T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton StreetCambridge, MA 02138 T 617.499.8000 F 617.499.8074 Architect 29 Stanhope Street 3rd FloorBoston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. TIONS N Per 26.575.020.D.1, General, FA measures all space within the surrounding exterior walls, including the walls themselves. Therefore, please include the square footage of these walls in your totals for this level. PLANTER 225 Drawin Drawin Project 18 F Please provide a section through this planter showing that it meets the restrictions within 26.575.020.D.4.e), Decks, in order for this planter to not count towards deck calculations. 1077.56 SQ F INTERIOR SPA Please provide some sort of proof that these closet spaces are full height in order for it all to count towards FA. Page: 11 Checkmark: Unchecked Author: jimp File Name: 1803_PERMIT SET_191115.pdf Provide hight points for this roof element over the attic. Being that it is in the footprint of the house, height will be measured to the natural grade directly below. Page: 11 Checkmark: Unchecked Author: jimp File Name: 1803_PERMIT SET_191115.pdf I'm not sure if I understand these heights. It looks to me as if, based on your elevations, that the roof of the west dormer should be higher than the roof of the dormers to the east. Based on the chart, this is switched. Please either correct the chart or show how what is shown is correct. Page: 11 Checkmark: Unchecked Author: jimp File Name: 1803_PERMIT SET_191115.pdf We will require height points for all of these valleys. Page: 11 Checkmark: Unchecked Author: jimp File Name: 1803_PERMIT SET_191115.pdf Please provide a height point on each side of the ridge line. Please be aware, that since the side of the ridge facing the south meets with a valley rising, the actual distance from the ridge to the eave point is diminishing,and therefore the 1/3 point will be climbing. Therefore, show multiple points along that pitch to show this changing height and compliance Page: 17 Checkmark: Unchecked Author: jimp File Name: 1803_PERMIT SET_191115.pdf According to the Mechanical drawings, these mechanical units will be extending into the rear setback. Please show how those units in the setback will be compliant with the restrictions in 26.575.020.E.5, Allowed Projections into Setbacks. Page: 17 Checkmark: Unchecked Author: jimp File Name: 1803_PERMIT SET_191115.pdf 20'-5 11/16" Page: 27 Checkmark: Unchecked Author: jimp File Name: 1803_PERMIT SET_191115.pdf Please add all height points to the elevations. 7922.37 SURVE 792 SU 7922.63 SURVEY POINT 7921.65 SURVEY POINT 7922.17 SURVEY POINT 7922.62 SURVEY POINT 7923.27 SURVEY POINT 7923.32 SURVEY POINT 7922.97 SURVEY POINT 7922.84 SURVEY POINT 7922.80 SURVEY POINT 7922.93 SURVEY POINT 792 SU 7922.79 792 SU 7922.95 SURVEY POINT 7921.98 SURVEY POINT ISH GRADE SET TO 7921.5 ALL POINTS ALONG EDGE PROPOSED RESIDENCE LIN E O F S E T B A C K LIN E O F S E T B A C K 6 5 3 2 4 8 7 Provide hight points for this roof element over the attic. Being that it is in the footprint of the house, height will be measured to the natural grade directly below. 1 7946'-6" 7936'-0 1/4" 7946'-6" 7941'-9" 7946'-0" 7944'-0" 25'-0" 14'-6 1/4" 25'-0" 20'-3" 24'-6" 22'-6" I'm not sure if I understand these heights. It looks to me as if, based on your elevations, that the roof of the west dormer should be higher than the roof of the dormers to the east. Based on the chart, this is switched. Please either correct the chart or show how what is shown is correct. 7921.40 SURVEY POINT 921.59 URVEY POINT 7921.21 SURVEY POINT 7921.35 SURVEY POINT 7921.15 SURVEY POINT 7922.02 SURVEY POIN 7922.37 SURVEY POIN 7922.35 SURVEY 7922.63 SURVEY POINT 7921.64 SURVEY POINT 7921.65 SURVEY POINT 7922.17 SURVEY POINT PROPERTY LINE PE R T Y L I N E EXISTING STRUCTURE LINE OF SETBACK LIN E O F S E T B A C K 6 1 2 8 7We will require height points for all of thesevalleys. 7922.23 SURVEY POINT SURVEY POINT 7922.63 SURVEY POINT 7923.32 SURVEY POINT 7922.97 SURVEY POINT 7922.84 SURVEY POINT 7922.80 SURVEY POINT 7922.93 SURVEY POINT 7922.64 SURVEY POINT 7922.41 SURVEY POINT 7922.95 SURVEY POINT PR O P E R T Y L I N E 6 5 Please provide a height point on each side of the ridge line. Please be aware, that since the side of the ridge facing the south meets with a valley rising, the actual distance from the ridge to the eave point is diminishing,and therefore the 1/3 point will be climbing. Therefore, show multiple points along that pitch to show this changing height and compliance OPERTY LINE DRIVEWAY IMPERVIOUS 5'-0" A3-031 According to the Mechanical drawings, these mechanical units will be extending into the rear setback. Please show how those units in the setback will be compliant with the restrictions in 26.575.020.E.5, Allowed Projections into Setbacks. DRIVEWAY IMPERVIOUS A3-03 1 20 ' - 5 1 1 / 1 6 " 25' - 0 " 31' - 6 " 9'- 9 " LEVEL 1 FINISH FLOOR7922' 2ND LEVEL FINISH FLOOR 7932' MEZZANINE FINISH FLOOR 7928' ATTIC LEVEL FINISH FLOOR 7937' FINISH GRADE7921.5' 8'- 0 " 101 108 208207 209 210 201 208 209 EQ EQ EQ NATURAL GRADE FINISH GRADE IS 7921.5' LOWPOINT ON EXISTING FACADE IS7921.59' FINISH GRADE IS MORERESTRICTIVE THAN NATURALGRADE AT ALL POINTS PITCH IS GREATER THAN 7:12,SHALL BE MEASURED FROM THEGROUND TO THE POINT OF THEROOF VERTICALLY ONE-THIRD OFTHE DISTANCE UP THE EAVEPOINT TO THE RIDGE. ONE-THIRDMEASUREMENT AT OR BELOW25'-0" AT ALL POINTS. 17.5 12 Please add all heightpoints to theelevations. Page: 27 Checkmark: Unchecked Author: jimp File Name: 1803_PERMIT SET_191115.pdf In order to ensure compliance, and because of the complicated nature of the roof plan, please provide a set of 3d drawings of the house, with an emphasis on showing the roof. Page: 32 Checkmark: Unchecked Author: jimp File Name: 1803_PERMIT SET_191115.pdf 7'-3 1/8" Page: 33 Checkmark: Unchecked Author: jimp File Name: 1803_PERMIT SET_191115.pdf Page: 33 Checkmark: Unchecked Author: jimp File Name: 1803_PERMIT SET_191115.pdf 0'-10 11/16" Page: 33 Checkmark: Unchecked Author: jimp File Name: 1803_PERMIT SET_191115.pdf 6'-5 5/8" Page: 4 Checkmark: Unchecked Author: jimp File Name: 191115_1803_PERMIT SET_LIGHTING CUT SHEETS EXTERIOR.pdf Please show how this lens is frosted in order to meet the City Outdoor lighting code. 191115_1803_PERMIT SET_LIGHTING CUT SHEETS EXTERIOR.pdf (1) In order to ensure compliance, and because of the complicated nature of the roof plan, please provide a set of 3d drawings of the house, with an emphasis on showing the roof. 7' - 0 " 3' - 0 " SH GRADE 1.5' 07 A12-01 012 7' - 3 1 / 8 " BEDROOM 3 216 SPORTS COURT 003 6" H FLOOR OOR 1'- 0 " 9'- 6 " 1'- 0 " 19 ' - 6 " 2'- 0 " 9'- 0 " H FLOOR H FLOOR FLOOR 31' - 0 " 2'- 4 " 10 ' - 4 " 15 ' - 6 " 4'- 0 " F - 5 13A12-01 11A12-01 07A12-01 F - 7 F - 1 DOG WASH 6 1/8" CORRIDOR 217 LIVING RO 222 10 ' - 0 " 014 207 113107 001 14 ' - 0 " WORKOUT ROOM 009 9'- 0 " 5'- 0 " 1'- 6 1 / 8 " 207 108 STAIR: 10" TREAD/7-5/8" R 11 RISERS THIS SEGM STAIR: 10" TREAD/7-5/8" RISER 10 RISERS THIS SEGMENT 1' - 0 " 6 1/8 0 5' - 0 " 1' - 6 1 / 8 " 0' - 1 0 1 1 / 1 6 " 1' - 0 " 9' - 6 " 07 A12-01 DOG WASH 6 1/8" 113 001 0" 1' - 6 1 / 8 " 6' - 5 5 / 8 " Please show how this lens is frosted in order to meet the City Outdoor lighting code.