Loading...
HomeMy WebLinkAboutFile Documents.617 W Bleeker St.0062-2019-BRES (2)0062-2019-BRES_Zoning_2 Page: Z0-08 HEIGHT OVER TOPOGRAPHY Checkmark: Unchecked Author: jimp File Name: 200409_ARCH_1803_PERMIT SET_200408.pdf I am not seeing pitches called out for any of these low angle roofs. Without a pitch, we would assume that it is less than 3:12. If so, then the height measurement point needs to be the highest point on any roof plane. 200409_ARCH_1803_PERMIT SET_200408.pdf (2) Page: Z0-09 HEIGHT OVER TOPOGRAPHY Checkmark: Unchecked Author: jimp File Name: 200409_ARCH_1803_PERMIT SET_200408.pdf This dormer/cupola is sitting on the low angle roof leading down to the side of the house. Per the language in 26.575.020.F.2.g, to be an exempt dormer, it cannot be taller then the roof it is sitting on. This is clearly taller, and therefore must meet height restrictions. I do not see a detail showing the pitch, but it appears to be less than 3:12. If so, then we will need a height point at the highest spot on the cupola, if more than 3:12, than we will need a point halfway up the roof line. Regardless, #12 and #15 do not appear to be the correct height points. 7921.59 SURVEY POINT 7922.02 SURVEY POINT 7922.17 SURVEY POINT 7922.37 SURVEY POINT 7922.23 SURVEY POINT 7922.35 SURVEY POINT 7922.63 SURVEY POINT 7921.64 SURVEY POINT 7922.62 SURVEY POINT 7923.27 SURVEY POINT 7923.32 SURVEY POINT 7922.97 SURVEY POINT 7922.84 SURVEY POINT 7922.80 SURVEY POINT 7922.93 SURVEY POINT 7922.64 SURVEY POINT 7922.41 SURVEY POINT 7922.79 SURVEY POINT 7923.58 SURVEY POINT 7923.60 SURVEY POINT 7922.95 SURVEY POINT 7921.98 SURVEY POINT 7921.65 SURVEY POINT 7922.17 SURVEY POINT PR O P E R T Y L I N E LINE OF SETBACK LIN E O F S E T B A C K 6 5 3 1 2 4 8 7 11 9 10 14 12 13 15 16 I am not seeing pitches called out for any of these low angle roofs. Without a pitch, we would assume that it is less than 3:12. If so, then the height measurement point needs to be the highest point on any roof plane. 7 7 8 1 9 10 4 6 12 14 15 16 XONOMETRIC = 1'-0"1 3D AXONOMETRIC SCALE: 1/8" = 1'-0" This dormer/cupola is sitting on the low angle roof leading down to the side of the house. Per the language in 26.575.020.F.2.g, to be an exempt dormer, it cannot be taller then the roof it is sitting on. This is clearly taller, and therefore must meetheight restrictions. I do not see a detail showing the pitch, but it appears to be less than 3:12. If so, then we will need a height point at the highest spoton the cupola, if more than 3:12, than we will need a point halfway up the roof line. Regardless, #12 and #15 do not appear to be the correct heightpoints.