File Documents.105 W Hyman Ave.0083-2023-BCHO (5)
SUBMITTAL DATA: MSZ-GL15NA MITSUBISHI M-SERIES 15,000 BTU/H WALL-MOUNTED INDOOR UNIT ELECTRIC HEATING&AIR CONDITIONING Job Name: System Reference: Date: Indoor Unit: Wireless Remote Controller MSZ-GL15NA � I GENERAL FEATURES • Slim wall-mounted indoor units provide zone comfort control • The outdoor unit powers the indoor unit,and should a power outage occur,the system is automatically restarted when power returns • Multiple fan speed options:Quiet,Low,Medium,High,Super-high,Auto • Multiple control options available: -Hand-held Remote Controller(provided with unit) -kumo cloud®smart device app for remote access -Third-party interface options -Wired or wireless controllers • Hot-Start Technology:no cold air rush at equipment startup or when restarting after Defrost Cycle • Quiet operation • Smart Set:recalls a preferred preset temperature setting at the touch of a button RECEIVED 08/24/2023 Specifications are subject to change without notice. ©2022 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SPECIFICATIONS: MSZ-GL15NA Cooling Capacity,3 BTU/H 14,000 Heating Capacity',3 BTU/H 18,000 Voltage,Phase,Frequency 208/230V,1 phase,60Hz Guaranteed Voltage Range V AC 187-253 Electrical Voltage:Indoor-Outdoor,S1-S2 V AC 208/230 Voltage:Indoor-Outdoor,S2-S3 V DC 24 Short-circuit Current Rating(SCCR) 5 MCA A 1 Blower Motor Full Load Amperage A 0.76 Blower Motor Output W 30 Airflow Rate at Cooling,Dry CFM 533-420-335-272-205 Airflow Rate at Cooling,Wet CFM 498-385-300-237-170 Airflow Rate at Heating,Dry CFM 463-367-304-247-205 Sound Pressure Level(Cooling) dB(A) 49-44-38-32-26 Sound Pressure Level(Heating) dB(A) 46-40-35-30-26 Drain Pipe Size In.(mm) 5/8(15.88) Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.0Y 9.2/0.2 W:In.(mm) 31-7/16(798) Unit Dimensions D:In.(mm) 9-1/8(232) H:In.(mm) 11-5/8(295) W:In.(mm) 33-1/2(850) Package Dimensions D:In.(mm) 12(300) H:In.(mm) 14(350) Unit Weight Lbs.(kg) 22(10) Package Weight Lbs.(kg) 26(11.5) Refrigerant Type R410A Gas Pipe Size O.D.(Flared) In.(mm) 1/2(12.7) Piping Liquid Pipe Size O.D.(Flared) In.(mm) 1/4(6.35) Notes: 'Cooling(Indoor//Outdoor) °F 80 DB,67 WB//95 DB,75 WB Nominal Conditions 'Heating at 47°F(Indoor//Outdoor) °F 70 DB,60 WB//47 DB,43 WB 'Capacity varies based on the number of indoor units operating and the model of the Multi-zone Outdoor Unit.For reference to connected capacity charts,please refer Multi-zone Outdoor Unit Operational Performance. RECEIVED 08/24/2023 A,opef"' Specifications are subject to change without notice. ©2022 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. ACCESSORIES: MSZ-GL15NA Anti-allergy Enzyme Filter ❑MAC-408FT-E kumo touch.RedLINK""Wireless Controller ❑MHK2 Deluxe MA Remote Controller' ❑PAR-40MAAU Simple MA Controller' ❑PAC-YT53CRAU-J Touch MA Controller' ❑PAR-CT01 MAU-SB Wired Remote Sensor ❑M21 EAA307 Wireless Temperature and Humidity Sensor ❑PAC-USWHS003-TH-1 System Control Interface2 ❑MAC-3341F-E Wireless Interface 2 ❑PAC-USWHS002-WF-2 Thermostat Interface ❑PAC-US444CN-1 Thermostat Interface ❑PAC-US445CN-1 kumo station®for kumo cloud® ❑PAC-WHS01 HC-E USNAP Interface ❑PAC-WHS01UP-E IT Extender ❑PAC-WHS011E-E BACnet®and MODBUS®Interface ❑PAC-UKPRC001-CN-1 Lockdown Bracket for Hand-held Remote Controllers ❑RCMKP1CB Blue Diamond Sensor Extension Cable-15 Ft. ❑C13-103 Blue Diamond Alarm Extension Cable-6.5 Ft. ❑C13-192 Blue Diamond MultiTank—collection tank for use with multiple pumps ❑C21-014 Blue Diamond Rubber Foot Pads ❑F10-010 Mini Condensate Pump-230 volt application ❑SI30-230 MegaBlue Advanced Blue Diamond Condensate Pump w/Reservoir&Sensor o X87-835-110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(110V)up to 48,000 BTU/H[recommended] ❑X87-711-110V Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(208/230V)[recommended] ❑X87-721-208/230V MicroBlue Blue Diamond Mini Condensate Pump(110/208/230V)up to 18,000 BTU/H o X85-003 Fascia Kit for MicroBlue Pump—mounts the MicroBlue and sensor directly beneath the indoor unit ❑T18-016 Refco Condensate Pump(100-240 VAC)up to 120,000 BTU/H o COMB! Refco Condensate Pump(100-240 VAC)up to 120,000 BTU/H ❑GOBI-II Drain Pan Level Sensor o SS610E (30A/600V/UL)[fits 2"X 4"utility box]-Black ❑TAZ-MS303 (30A/600V/UL)[fits 2"X 4"utility box]-White ❑TAZ-MS303W Flexible Mini-Split Drain Hose ❑DRX-16 Requires MAC-3341F-E 2 Allows indoor units to connect to an MA Controller RECEIVED 08/24/2023 A,opef"' Specifications are subject to change without notice. ©2022 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. DIMENSIONS: MSZ-GL15NA Unit: inch 1/16x1 Oblong hole 1/16x13/16 Oblong hole Installation plate 3-1/8_ < 8-7/8 8-7/8 , ,3-1/8 co A n 0 31-7/16 A 30-15/16 _I I/4 0 'TrI1--I•I---■il vy IIt__mpim__■■II ,^ . 6-1/8,�6-1/8, �^ ^ —"'— . - 2-3/8, 13-5/16 13-9/16 2-I/8 9-1/8 Air in all hole b3 3/16 Indoor unit n 1IJ I Installation date ,,,_ _ Plllnr ___ ,, ,,,_ ,.., _ _ . ..._ _V .,�0. ' 1; `— -III.---.. ` j I-5/8 13/4 I l5/I6 1, 24-3/8 5 /8, .. 4-3/I6,,- Drain hose ir. MN 2-5/161 k _IL \ 11 - Air out\ --e. H _ IL v a %.. '.34L ,-, ,--, — — Insulation 01-3/8 0.D °W _ A ) ( )j 0 0 a Liquid line 01/4 19-11/16(Flared connection 01/4) ^ 'a Gas line 03/8 16-15/16 2 3/ 6 15/ 6_"' 3/16 (Flared connection:03/8(06/09/12 KBTU/H),01/2(15 KBTU/H) , Drain hose Insulation 01-1/8 O.D Connected part 05/8 0.D 1340 Satellite Boulevard,Suwanee,GA 30024 Toll Fre- t E/ 4 cc /2023 J TI' " '°"" FORM#MSZ-GL15NA FOR MULTI-ZONE HEAT PUMP SYSTEM-202209 •��'"•"""'"'°" 08 Qop�(\ Specifications are subject to change without notice. ©2022 Mitsubishi Electric Trane HVAC US LLC.All rights reserved.