HomeMy WebLinkAboutFile Documents.617 W Bleeker St.0062-2019-BRES (10)CONTROLLER 120 VAC POWER REQUIRED 30 30 40 30 30 30 POC SIZE: 3/4-INCH PRESSURE: 60 PSI FLOW: 10 GPM A2 9.0 Tree 1" A1 5.1 0.38 1" A3 11.5 0.99 1" A4 11.5 0.98 1" A5 4.48 Shrub 1" A6 7.28 Shrub 1" C F 1 2 K K K M M M M M 3 3 3 3 RST M M L SST A1141" INDICATES LATERAL DISCHARGE (GPM) INDICATES VALVE SIZE (INCHES) INDICATES CONTROLLER AND STATION NUMBER INDICATES PRECIP. RATE (INCHES PER HOUR)0.50 30 INDICATES ZONE DESIGN PRESSURE (PSI) IRRIGATION LEGEND THE IRRIGATION SYSTEM POINT-OF-CONNECTION (POC) SHALL BE DOWNSTREAM OF THE IRRIGATION WATER TAP AND METER INSTALLED BY OTHERS AT THE APPROXIMATE LOCATION SHOWN. INSTALL BACKFLOW PREVENTION UNIT AND MASTER VALVE ASSEMBLY AS INDICATED, SAME SIZE AS POC. VERIFY EXACT LOCATION OF POC WITH OWNER'S REPRESENTATIVE. WALL MOUNT THE IRRIGATION CONTROLLER AT THE APPROXIMATE LOCATION SHOWN. COORDINATE ELECTRICAL POWER TO THE CONTROLLER WITH THE OWNER'S REPRESENTATIVE. CARE SHOULD BE TAKEN TO INSTALL THE IRRIGATION CONTROLLER IN A LOCATION THAT IS ACCESSIBLE FOR MAINTENANCE, AND SCREENED FROM VIEW EITHER BEHIND ENTRY WALLS, NEXT TO BUILDINGS, OR BEHIND PLANT MATERIAL. FINAL LOCATION TO BE APPROVED BY OWNER'S REPRESENTATIVE. IRRIGATION CONTRACTOR SHALL HAND DIG AROUND IN APPROXIMATE AREA WHEN THERE ARE EXISTING TREES AND AVOID CUTTING ANY ROOTS LARGER THAN 1-INCH IN DIAMETER INSTALLATION GENERAL NOTES CONSTRUCTION NOTES 1.THE SYSTEM DESIGN ASSUMES A MINIMUM DYNAMIC PRESSURE FOR THE IRRIGATION SYSTEM OF 60 PSI (PER CITY ENGINEER), AT A MAXIMUM DISCHARGE OF 12 GPM AT THE 3/4-INCH IRRIGATION POINT-OF-CONNECTION (POC). TAP, METER, BACKFLOW, AND MASTER VALVE SHALL ALL BE THE SAME SIZE. VERIFY PRESSURE AND FLOW ON SITE PRIOR TO CONSTRUCTION. 2.READ THOROUGHLY AND BECOME FAMILIAR WITH THE SPECIFICATIONS AND INSTALLATION DETAILS FOR THIS AND RELATED WORK PRIOR TO CONSTRUCTION. 3.COORDINATE UTILITY LOCATES ("CALL BEFORE YOU DIG") OF UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. 4.DO NOT PROCEED WITH THE INSTALLATION OF THE IRRIGATION SYSTEM WHEN IT IS OBVIOUS IN THE FIELD THAT OBSTRUCTIONS OR GRADE DIFFERENCES EXIST THAT MIGHT NOT HAVE BEEN CONSIDERED IN THE ENGINEERING. IF DISCREPANCIES IN CONSTRUCTION DETAILS, LEGEND, NOTES, OR SPECIFICATIONS ARE DISCOVERED, BRING ALL SUCH OBSTRUCTIONS OR DISCREPANCIES TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE. 5.THE DRAWINGS ARE DIAGRAMMATIC. THEREFORE, THE FOLLOWING SHOULD BE NOTED: A.ALTHOUGH IRRIGATION COMPONENTS MAY BE SHOWN OUTSIDE PLANTING AREAS FOR CLARITY, INSTALL IRRIGATION PIPE AND WIRING IN LANDSCAPED AREAS WHENEVER POSSIBLE. B.TREE AND SHRUB LOCATIONS AS SHOWN ON LANDSCAPE PLANS TAKE PRECEDENCE OVER IRRIGATION EQUIPMENT LOCATIONS. AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM, PLANTING MATERIALS, AND ARCHITECTURAL FEATURES. C.USE ONLY STANDARD TEES AND ELBOW FITTINGS. USE OF TEES IN THE BULLNOSE CONFIGURATION, OR USE OF CROSS TYPE FITTINGS IS NOT ALLOWED. 6.PROVIDE THE FOLLOWING COMPONENTS TO THE OWNER PRIOR TO THE COMPLETION OF THE PROJECT: A.TWO (2) OPERATING KEYS FOR EACH TYPE OF MANUALLY OPERATED VALVES. B.TWO (2) OF EACH SERVICING WRENCH OR TOOL NEEDED FOR COMPLETE ACCESS, ADJUSTMENT, AND REPAIR OF ALL ROTARY SPRINKLERS. 7.SELECT NOZZLES FOR SPRAY AND ROTARY SPRINKLERS WITH ARCS WHICH PROVIDE COMPLETE AND ADEQUATE COVERAGE WITH MINIMUM OVERSPRAY FOR THE SITE CONDITIONS. CAREFULLY ADJUST THE RADIUS OF THROW AND ARC OF COVERAGE OF EACH ROTARY SPRINKLER TO PROVIDE THE BEST PERFORMANCE. 8.THE IRRIGATION CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF IRRIGATION SLEEVING. SLEEVES ARE REQUIRED FOR BOTH PIPING AND ELECTRICAL WIRING AT EACH HARDSCAPE CROSSING. COORDINATE INSTALLATION OF SLEEVING WITH OTHER TRADES. ANY PIPE OR WIRE WHICH PASSES BENEATH EXISTING HARDSCAPE WHERE SLEEVING WAS NOT INSTALLED WILL REQUIRE HORIZONTAL BORING BY THE IRRIGATION CONTRACTOR. PIPE SLEEVES SHALL BE SIZED TWICE THE NOMINAL SIZE OF THE PIPE PASSING THROUGH. 9.INSTALL ALL ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE LOCAL ELECTRIC UTILITY CODES. 10.THE FOLLOWING SHOULD BE NOTED REGARDING PIPE SIZING: IF A SECTION OF UNSIZED PIPE IS LOCATED BETWEEN THE IDENTICALLY SIZED SECTIONS, THE UNSIZED PIPE IS THE SAME NOMINAL SIZE AS THE TWO SIZED SECTIONS. THE UNSIZED PIPE SHOULD NOT BE CONFUSED WITH THE DEFAULT PIPE SIZE NOTED IN THE LEGEND. 11.INSTALL TWO (2) #14 AWG CONTROL WIRES , FOR USE AS SPARES. INSTALL SPARE WIRES FROM CONTROLLER LOCATION TO EACH DEAD-END OF MAINLINE. COIL 3 FEET OF WIRE IN VALVE BOX. REMOTE CONTROL DRIP VALVE ASSEMBLY:RAIN BIRD XCZ-PRB-100-COM QUICK COUPLING VALVE ASSEMBLY:RAIN BIRD 5RC POINT-OF-CONNECTION ASSEMBLYPOINT-OF-CONNECTION ASSEMBLY BACKFLOW PREVENTION ASSEMBLY:FEBCO 825YA UNCONNECTED PIPE CROSSING IRRIGATION CONTROL WIRESC IN CONDUIT OR WITH WARNING TAPE LATERAL PIPE TO SPRINKLERS: 1-INCH SIZE UNLESS OTHERWISE INDICATED CLASS 200 PVC MAINLINE PIPE: 1 1/4-INCH SIZE UNLESS OTHERWISE INDICATED CLASS 200 PVC SLEEVES:CLASS 200 PVC MASTER VALVE ASSEMBLY:1-INCH WEATHERMATIC MAX-DW FLUSH CAP ASSEMBLY POP-UP SPRAY SPRINKLER: PRESSURE: RADIUS: FLOW (GPM): WEATHERMATIC MAX6PRS30-CV W/RAIN BIRD U-SERIES NOZZLES 10 FEET30 PSI Q-0.41 H-0.82 F-1.64 INLINE DRIP TUBING:NETAFIM TLCV26-12 WITH RAINBIRD XQF DRIPLINE HEADER IRRIGATION PIPE SCHEDULE CLASS 200 PVC PIPE SIZE FLOW (GPM) 1-INCH 0-15 1.25-INCH 16-25 1.5-INCH 26-35 2-INCH 36-55 2.5-INCH 56-80 3-INCH 81-110 4-INCH 111-200 IF THERE IS A DISCREPANCY BETWEEN PIPE SIZES SHOWN ON THE DRAWINGS AND THIS PIPE SCHEDULE, IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT THE IRRIGATION DESIGNER FOR CLARIFICATION. REMOTE CONTROL VALVE ASSEMBLY FOR SPRINKLER LATERALS: WEATHERMATIC MAX-DW (SIZED PER PLAN) FLOW SENSOR ASSEMBLY:F WEATHERMATIC SLFSI-T10 1 2 TREE BUBBLER ASSEMBLY: PRESSURE: FLOW (GPM): (2) RAIN BIRD 1402 BUBBLERS 30 PSI 0.50 PER BUBBLER; 1.00 PER ASSEMBLY 3 POP-UP ROTATING SPRAY SPRINKLER: PRESSURE: RADIUS: FLOW (GPM): LM O 40 PSI WEATHERMATIC MAX6PRS40-CV W/HUNTER MP1000 NOZZLES 8 FEET TO 15 FEET M-0.42 L-0.63 O-0.84 POP-UP ROTATING SPRAY SPRINKLER: PRESSURE: RADIUS: FLOW (GPM): RGK 40 PSI WEATHERMATIC MAX6PRS40-CV W/HUNTER MP2000 NOZZLES 13 FEET TO 21 FEET K-0.77 G-1.10 R-1.48 IRRIGATION CONTROLLER UNIT WITHC VAR#119180 *THE IRRIGATION CONTROLLER INCLUDES A WEATHERMATIC SMARTLINK VAR PACKAGED SYSTEM AND MANAGED SERVICES. PLEASE CONTACT PARRY WEBB WITH WEATHERMATIC FOR PRICING 303-638-6268* LOCKABLE VALVE PER ASPEN WELS SECTION 5.1.3 LATERAL PIPE TO INLINE DRIP HEADER: 1-INCH SIZE UNLESS OTHERWISE INDICATED CLASS 200 PVC LATERAL PIPE TO TREE BUBBLERS: 1-INCH SIZE UNLESS OTHERWISE INDICATED CLASS 200 PVC POP-UP ROTATING SPRAY SPRINKLER: PRESSURE: RADIUS: FLOW (GPM): LST RST SST 40 PSI WEATHERMATIC MAX6PRS40-CV W/HUNTER MPSTRIP NOZZLES SST - 4'X24'-0.34 5'X30'-0.47 LCS/RCS - 4'X12'-0.17 5'X15'-0.23 ADJUSTABLE RECTANGULAR SPRAY IRRIGATION PLAN IR-1.0 1 IRRIGATION PLAN SCALE: 1/8" = 1'-0" GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 IRRIGATION DESIGN RE S I D E N C E 09/20/2019 PERMIT SET JB MR1 N 11/20/2019 Sheet L-2 indicates that this area will receive "bubbler irrigation" in a Low hydrozone. Please revise plans accordingly. BACKFLOW PREVENTION UNIT ASSEMBLY1 32 4 5 6 7 8 9 10 11 FLOW SENSOR ASSEMBLY ISOLATION GATE VALVE ASSEMBLY QUICK COUPLING VALVE ASSEMBLY REMOTE CONTROL TURF VALVE ASSEMBLY REMOTE CONTROL DRIP VALVE ASSEMBLY PVC TECHLINE CONNECTION SUBSURFACE DRIP ASSEMBLY IN SHRUB BEDS DRIP FLUSH CAP ASSEMBLY 12 6-INCH POP UP SPRAY SPRINKLER ASSEMBLY MASTER VALVE ASSEMBLY 6-INCH POP UP MP-ROTATOR ASSEMBLY IRRIGATION DETAILS IR2.0 GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 IRRIGATION DESIGN RE S I D E N C E 09/20/2019 PERMIT SET JB MR1 11/20/2019 TYPICAL TRENCHING DETAIL TYPICAL SLEEVING DETAIL BUBBLER ASSEMBLY FOR TREES 13 WALL MOUNT CONTROLLER ASSEMBLY 15 16 17 TYPICAL VALVE BOX INSTALLATION RCV A1 RCV A2 RCV A3 QC 14 IRRIGATION DETAILS IR2.1 GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 IRRIGATION DESIGN RE S I D E N C E 09/20/2019 PERMIT SET JB MR1 11/20/2019