HomeMy WebLinkAboutFile Documents.617 W Bleeker St.0062-2019-BRES (15)0062-2019-bres_building comments_1 Subject: PlanCheck Page Label: 18 Page Index: 18 Author: tonyf Date: 1/28/2020 2:17:22 PM File Name: 1803_PERMIT SET_191115.pdf Please detail this emergency escape well, showing compliance with sec R310.2.3. 1803_PERMIT SET_191115.pdf (10) Subject: PlanCheck Page Label: 20 Page Index: 20 Author: tonyf Date: 1/24/2020 3:30:24 PM File Name: 1803_PERMIT SET_191115.pdf Please provide details of this construction: section, guardrail, etc. Subject: PlanCheck Page Label: 32 Page Index: 32 Author: tonyf Date: 1/28/2020 2:09:10 PM File Name: 1803_PERMIT SET_191115.pdf Please submit sheet A12. Subject: PlanCheck Page Label: 34 Page Index: 34 Author: tonyf Date: 1/24/2020 2:59:58 PM File Name: 1803_PERMIT SET_191115.pdf Insulation for conditioned basement must be continuous, insulation values must comply with IECC Table R402.1.2, please revise. Subject: PlanCheck Page Label: 34 Page Index: 34 Author: tonyf Date: 1/28/2020 1:54:29 PM File Name: 1803_PERMIT SET_191115.pdf Provide documentation that the roof assembly is Class A. This is typically either an ESR or UL report. Revise you roof detail to match the report. (Ordinance 40, 2016) 012 3 1 1 3' - 0 " 9' - 2 " 001 002 UP 1 A3-02 Please detail this emergency escape well, showing compliance with sec R310.2.3. DN DINING ROOM 203 CORRIDOR 202 CORRIDOR 207 2 1 1 14 ' - 1 0 1 / 2 " 38 ' - 0 " 40 ' - 7 " 45 ' - 0 " 202 209 Please provide details of this construction: section, guardrail, etc. 1' - 0 " 8' - 0 " 4' - 1 1 3 / 8 " F - 5 02 A12-01 06 A12-01 CORRIDOR 221 DINING ROOM 203 201 4' - 0 " 4' - 0 " 2' - 6 1 / 2 " Please submit sheet A12. 2'-0 " STRUCTURAL DRAWINGS 58" GWB CEILING; LEVEL 5 FINISH ACCOYA 18" SHINGLES W/ 8" EXPOSED FACE; STAGGERED GAPS HORIZONTAL 1X3 SLATS; SPACED 8" AND NAIL TO RAFTERS NOT PLYWOOD -INTERIOR FINISH (VARIES) 8" 2 3/8"6" DRIP FLASHING WALL ASSEMBLY -3/4" WOOD SIDING -3/4" BREATHABLE PLASTIC FURRING STRIP -BLUE SKIN 100 BUILDING WRAP -3/4" CBX PLYWOOD SHEATHING-2x4 FRAMING WALL; WITH INSULATION -INTERIOR FINISH (VARIES) PLYWOOD SHEATHING BUG SCREEN HORIZONTAL 1X3 SLATS; SPACED 8" AND NAIL TO RAFTERS NOT PLYWOOD STONE PERIMETER RIVERROCK (SLOPE AWAY FROM FOUNDATION) OVER CRUSHED STONE, SEE LANDSCAPE DRAWINGS. BASEMENT WALL ASSEMBLY -2.125" DOW STYROFOAM PERIMATE RIGID FOAM INSULATION DRAINAGE BOARD -WATERPROOFING (EXTEND FROM TOP OF WALL OVER FOOTING TO 2" DOWN FACE OF FOOTING)-12" CAST-IN-PLACE CONCRETE FOUNDATION WALL, SEE STRUCTURAL DWGS -1" CONTINUOUS GAP BETWEEN FOUNDATION & STUD WALL -2X4 WOOD STUDS @ 16" O.C. WITH INSULATION -5/8" GWB FIRST FLOOR ASSEMBLY -HARDWOOD FLOORING -ASPHALT FELT UNDERLAYMENT -5/8" HEATING TUBES EMBEDDED IN MORTAR BED, INCLUDES 5/8" MIN. COVER -LATH-TAR PAPER -3/4" FORMALDEHYDE-FREE PLYWOOD -FLOOR JOISTS, SEE STRUCTURAL DWGS -CAVITY -USG DRYWALL SUSPENSION SYSTEM -5/8" GWB 6" 9 1 / 4 " 8" 3 3/4"6 1/4" 10" 8 3/8" 2 3/8"6" PLYWOOD SHEATHING BUG SCREEN DRIP FLASHING ACCOYA 18" SHINGLES W/ 8" EXPOSED FACE; STAGGERED GAPS WALL ASSEMBLY -3/4" WOOD SIDING -3/4" BREATHABLE PLASTIC FURRING STRIP -BLUE SKIN 100 BUILDING WRAP -3/4" CBX PLYWOOD SHEATHING -2x4 FRAMING WALL; WITHINSULATION -INTERIOR FINISH (VARIES) 6 7/8"1 1/2" 8 3/8" 3 1/ 8 " ANDERSON E-SERIES WINDOWS FIXED, TYP. WALL ASSEMBLY -3/4" WOOD SIDING -3/4" BREATHABLE PLASTIC METAL FLASHING Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architect P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNERHines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 DATE & ISSUE DESCRIPTION ISSUE/ REVISION RE S I D E N C E 05/03/2019 RDS SET1 05/15/2019 RDS SET2 09/24/2019 WELS SET3 10/22/2019 PERMIT SET4 11/15/2019 PERMIT SET5 3 RIDGE DETAIL SCALE: 1-1/2"= 1'-0"4 ROOF/WALL DETAIL SCALE: 1-1/2"= 1'-0" 5 BASEMENT WALL DETAIL SCALE: 1-1/2"= 1'-0" Insulation for conditioned basement must be continuous, insulation values must comply with IECC Table R402.1.2, please revise. 1'- 0 " 6 5 / 8 " 2 3 / 4 " Provide documentation that the roof assembly is Class A. This is typically either an ESR or UL report. Revise you roof detail to match the report. (Ordinance 40, 2016) These detail markers have been deleted from the drawing set See A3-03, drawing 1 and A4-07 Drawings 1,2, and 3 for details for emergency escape showing compliance with R310.2.3. See A4-06 Stair Details for material assembly, heights for handrails and guardrails. Details and RESCheck have been updated based on comments to show compliance. UL provided 04/13/2020 Subject: PlanCheck Page Label: 34 Page Index: 34 Author: tonyf Date: 1/28/2020 1:48:42 PM File Name: 1803_PERMIT SET_191115.pdf Please provide more details showing assembly members, including insulation R-values and types matching REScheck document as submitted. Include detail showing vented airspace under shingles as req'd by COA amended Sec R905.8.10, Ord 40-2016. Subject: PlanCheck Page Label: 34 Page Index: 34 Author: tonyf Date: 1/28/2020 10:38:33 AM File Name: 1803_PERMIT SET_191115.pdf Specify insulation values; insulation must be continuous. Typical. Subject: PlanCheck Page Label: 34 Page Index: 34 Author: tonyf Date: 1/28/2020 10:54:57 AM File Name: 1803_PERMIT SET_191115.pdf REScheck document shows R-5 continuous insulation on all exterior walls; please include this insulation in all exterior wall sections. Subject: PlanCheck Page Label: 34 Page Index: 34 Author: tonyf Date: 1/28/2020 1:55:01 PM File Name: 1803_PERMIT SET_191115.pdf Please provide more details showing the above-grade wall assembly members including cavity and continuous insulations with their R-values. Subject: PlanCheck Page Label: 38 Page Index: 38 Author: tonyf Date: 1/24/2020 12:41:01 PM File Name: 1803_PERMIT SET_191115.pdf handrail req'd at 34"-38"; outside diameter must be 1-1/4" to 2" (R311.7.8.3) Please revise. RIDGE BOARD MITERED JOINTS, TYPICAL AT ROOF PEAK SELF ADHESIVE FLASHING @ PEAK OVER BUILDING WRAP RAFTER; SEE STRUCTURAL DRAWINGS PLYWOOD SHEATHING BLUE SKIN 100 BUILDING WRAP; TO OVERLAP PEAK AT LEAST 1'-0" 58" GWB CEILING; LEVEL 5 FINISH 1'-0 " 6" 2 5/ 8 " 6 5 / 8 " 2 3/ 4 " 3" ROOF ASSEMBLY -DELTA MILLWORKS KEBONY CLASS B SHINGLES -ORGANIC FELT -MINIMUM 1/4" DENSDECK ROOF BOARD AS A WOOD SHINGLE UNDERLAYMENT ON A COMBUSTIBLE DECK ASSEMBLY TO ACHIEVE A UL CLASS A FIRE RATING -BLUE SKIN 100 BUILDING WRAP; INSTALL SEAMS AND BOTTOM DRIP EDGE ACCORDING TO MANUFACTURER -PLYWOOD SHEATHING 2 6" 1'-0" 2 5/8 " 6 5/8" 2 3/4 " 3 RIDGE DETAIL 4 ROOF/WALL DE Please provide more details showing assembly members, including insulation R-values and types matching REScheck document as submitted. Include detail showing vented airspace under shingles as req'd by COA amended Sec R905.8.10, Ord 40-2016. OR ASSEMBLY OORING T UNDERLAYMENT EHYDE-FREE PLYWOOD B, SEE STRUCTURAL DWGS HTYLENE. ALL SEAMS SEALED HANE CAULK L ASSEMBLY YROFOAM PERIMATE RIGID FOAM AINAGE BOARD G (EXTEND FROM TOP OF WALL TO 2" DOWN FACE OF FOOTING) LACE CONCRETE FOUNDATION RUCTURAL DWGS GAP BETWEEN FOUNDATION & UDS @ 16" O.C. ON RROCK (SLOPE AWAY FROM FOUNDATION) STONE, SEE LANDSCAPE DRAWINGS. ERIES WINDOWS FIXED, TYP. G; LEVEL 5 Specify insulation values; insulation must be continuous. Typical. PLYWOOD SHEATHING ANDERSON E-SERIES WINDOWS FIXED, TYP. BUG SCREEN DRIP FLASHING WALL ASSEMBLY -3/4" WOOD SIDING -3/4" BREATHABLE PLASTIC FURRING STRIP -BLUE SKIN 100 BUILDING WRAP -3/4" CBX PLYWOOD SHEATHING -2x4 FRAMING WALL; WITH INSULATION -INTERIOR FINISH (VARIES) ANDERSON E-SERIES WINDOWS FIXED, TYP. WALL ASSEMBLY -3/4" WOOD SIDING -3/4" BREATHABLE PLASTIC FURRING STRIP -BLUE SKIN 100 BUILDING WRAP -3/4" CBX PLYWOOD SHEATHING -2x4 FRAMING WALL; WITH INSULATION -INTERIOR FINISH (VARIES) ACCOYA 18" SHINGLES W/ 8" EXPOSED FACE; STAGGERED GAPS PLYWOOD SHEATHING METAL FLASHING 6 7/8" 1 1/2" 8 3/8" 6 1/4"4 3/4" 5 1 / 8 " 6 WINDOW SILL DETAIL SCALE: 1-1/2"= 1'-0"7 WINDOW LINTEL DETAIL SCALE: 1-1/2"= 1'-0" REScheck document shows R-5 continuous insulation on all exterior walls; please include this insulation in all exterior wall sections. 2'-0 " RAFTER; SEE STRUCTURAL DRAWINGS PLYWOOD SHEATHING 58" GWB CEILING; LEVEL 5 FINISH 1'-0" 2 5/ 8 " 6 5/8 " 2 3/ 4 " 3" ROOF ASSEMBLY -DELTA MILLWORKS KEBONY CLASS B SHINGLES -ORGANIC FELT -MINIMUM 1/4" DENSDECK ROOF BOARD AS A WOOD SHINGLE UNDERLAYMENT ON A COMBUSTIBLE DECK ASSEMBLY TO ACHIEVE A UL CLASS A FIRE RATING -BLUE SKIN 100 BUILDING WRAP; INSTALL SEAMS AND BOTTOM DRIP EDGE ACCORDING TO MANUFACTURER -PLYWOOD SHEATHING RAFTER; SEE STRUCTURAL DRAWINGS ACCOYA 18" SHINGLES W/ 8" EXPOSED FACE; STAGGERED GAPS HORIZONTAL 1X3 SLATS; SPACED 8" AND NAIL TO RAFTERS NOT PLYWOOD WALL ASSEMBLY -3/4" WOOD SIDING -3/4" BREATHABLE PLASTIC FURRING STRIP -BLUE SKIN 100 BUILDING WRAP -3/4" CBX PLYWOOD SHEATHING -2x4 FRAMING WALL; WITH INSULATION -INTERIOR FINISH (VARIES) 3" 8" 8" STEEL ANGLE 58" GWB CEILING; LEVEL 5 FINISH 2 3/8"6" 1'-0" 2 5/8" 6 5/8" 2 3/4 " WRAP; INSTALL SEAMS AND BOTTOM DRIP EDGE ACCORDING TO MANUFACTURER -PLYWOOD SHEATHING DRIP FLASHING WALL ASSEMBLY -3/4" WOOD SIDING -3/4" BREATHABLE PLASTIC FURRING STRIP -BLUE SKIN 100 BUILDING WRAP -3/4" CBX PLYWOOD SHEATHING -2x4 FRAMING WALL; WITH INSULATION -INTERIOR FINISH (VARIES) PLYWOOD SHEATHING BUG SCREEN HORIZONTAL 1X3 SLATS; SPACED 8" AND NAIL TO RAFTERS NOT PLYWOOD STONE PERIMETER RIVERROCK (SLOPE AWAY FROM FOUNDATION) OVER CRUSHED STONE, SEE LANDSCAPE DRAWINGS. BASEMENT WALL ASSEMBLY -2.125" DOW STYROFOAM PERIMATE RIGID FOAM INSULATION DRAINAGE BOARD -WATERPROOFING (EXTEND FROM TOP OF WALL OVER FOOTING TO 2" DOWN FACE OF FOOTING) -12" CAST-IN-PLACE CONCRETE FOUNDATION WALL, SEE STRUCTURAL DWGS -1" CONTINUOUS GAP BETWEEN FOUNDATION & STUD WALL -2X4 WOOD STUDS @ 16" O.C. WITH INSULATION -5/8" GWB FIRST FLOOR ASSEMBLY -HARDWOOD FLOORING -ASPHALT FELT UNDERLAYMENT -5/8" HEATING TUBES EMBEDDED IN MORTAR BED, INCLUDES 5/8" MIN. COVER -LATH -TAR PAPER -3/4" FORMALDEHYDE-FREE PLYWOOD -FLOOR JOISTS, SEE STRUCTURAL DWGS -CAVITY -USG DRYWALL SUSPENSION SYSTEM -5/8" GWB 6" 9 1 / 4 " 8" 3 3/4"6 1/4" 10" 8 3/8" 2 3/8"6" GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, In 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Archit P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N DATE & ISSUE DESCRIPTIONISSUE/REVISION RE S I D E N C E 05/03/2019 RDS SET1 05/15/2019 RDS SET2 3 RIDGE DETAIL SCALE: 1-1/2"= 1'-0"4 ROOF/WALL DETAIL SCALE: 1-1/2"= 1'-0" 5 BASEMENT WALL DETAIL SCALE: 1-1/2"= 1'-0" Please provide more details showing the above-grade wall assembly members including cavity and continuous insulations with their R-values. 8 R I S E R S A T 7 3 / 4 " = 5 ' - 2 " 3' - 6 " D A4- handrail req'd at 34"-38"; outside diameter must be 1-1/4" to 2" (R311.7.8.3) Please revise. RESCHECK AND DETAILS HAVE BEEN COORDINATED AND REVISED, R- VALUES SHOWN ON DETAILS RESCHECK AND DETAILS HAVE BEEN COORDINATED AND REVISED STAIR DETAILS HAVE BEEN REVISED RESCHECK AND DETAILS HAVE BEEN COORDINATED AND REVISED, R- VALUES SHOWN ON DETAILS RESCHECK AND DETAIL REVISED AND INCLUDE R-VALUES, 1/4" AIRSPACE SHOWN IN DETAIL PER ORD 40-2016 04/13/2020 Subject: PlanCheck Page Label: 1 Page Index: 1 Author: tonyf Date: 1/28/2020 11:41:26 AM File Name: 191115_617 W Bleeker Res Check.pdf Floor 1 is not a slab-on-grade as it is more than 12" below grade. Please include an assembly for the typical conditioned basement walls. Wall 1 includes R-5 continuous insulation, which does not appear in the wall sections: please revise those sections. 191115_617 W Bleeker Res Check.pdf (1) Subject: PlanCheck Page Label: [10] Unsaved Drawing1-M3-1 Page Index: 10 Author: tonyf Date: 1/28/2020 1:03:16 PM File Name: MECH PLUMB.pdf Provide a balanced whole house mechanical ventilation system complying with Ordinance 40, 2016. Show the location of all equipment and intakes and exhausts. Indicate the rate of air supplied and exhausted. Indicate method of operation and whether it is continuous or periodic. Show your calculations using this equation: Min vent rate = ((0.01 x floor area) + [7.5 x (#bedrooms + 1)]) x 0.75 MECH PLUMB.pdf (1) Compliance Certificate Project 617 W Bleeker Energy Code:2015 IECC Location:Aspen, Colorado Construction Type:Single-family Project Type:New Construction Conditioned Floor Area:8,235 ft2 Glazing Area 59% Climate Zone:7 (9922 HDD) Permit Date: Construction Site: 617 W Bleeker Aspen, CO Owner/Agent: Rachel K & Mark Schwartz 1061 Country Club Rd Bloomfield Hills, MI 48304 2486440271 Mark@mssphd.com Designer/Contractor: Monica Ponce de Leon MPDL 416 W 13 Street Boston, MA 02116 6174260995 Permit Number: Compliance: Passes using UA trade-off 5.4% Better Than Code Maximum UA:3556 Your UA:3364 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Compliance: Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA Floor 1: Slab-On-Grade:Unheated Insulation depth: 4.0' 2,779 10.0 0.684 1901 Wall 1: Wood Frame, 16" o.c.7,650 20.0 5.0 0.044 139 Window 1: Vinyl/Fiberglass Frame:Double Pane 4,500 0.280 1260 Ceiling 1: Flat Ceiling or Scissor Truss 2,790 49.0 5.0 0.023 64 Name - Title Signature Date Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.5 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Floor 1 is not a slab-on-grade as it is more than 12" below grade. Please include an assembly for the typical conditioned basement walls. Wall 1 includes R-5 continuous insulation, which does not appear in the wall sections: please revise those sections. Provide a balanced whole house mechanical ventilation system complying with Ordinance 40, 2016. Show the location of all equipment and intakes and exhausts. Indicate the rate of air supplied and exhausted. Indicate method of operation and whether it is continuous or periodic. Show your calculations using this equation: Min vent rate = ((0.01 x floor area) + [7.5 x (#bedrooms + 1)]) x 0.75 THE AMOUNT OF OUTSIDE AIR PROVIDED INTO THE HOUSE VIA THE ERV UNITS SURPASSES THE MINIMUMS BY A GREAT DEAL. RUN TIMES ARE NOTED IN SCHEDULES. RESCHECK AND DETAILS HAVE BEEN COORDINATED AND REVISED 04/13/2020