HomeMy WebLinkAboutFile Documents.617 W Bleeker St.0062-2019-BRES (26)FC 5 H 5 FC 2 H 2 FC 3 H 3 EF 1 6"Ø 150 CFM TYPE A 150 CFM TYPE A 150 CFM TYPE A 150 CFM TYPE A 150 CFM TYPE A 150 CFM TYPE A 150 CFM TYPE A 150 CFM TYPE A 150 CFM TYPE A 150 CFM TYPE A 150 CFM TYPE A 10"Ø 8" Ø 12"X8" 8" Ø 8" Ø 12"X12" 1 0 " X 8 " 10"X8" 2 4 " X 1 4 " 1 6 " X 1 0 " 20"X12" 8"Ø 8"Ø 8"Ø 8"Ø 24"X14"6"Ø 6"Ø 8"Ø 1 0 " X 8 " 50 CFM TYPE A 10 " X 1 0 " 10"X10" 10"X10" 8" Ø 8" Ø 8" Ø 8" Ø 8" Ø 20 " X 1 0 " 8" Ø 8" Ø 8" Ø 8" Ø 8" Ø 8" Ø 6" Ø 8" Ø 8" Ø 10 " Ø 6"Ø 14 " X 1 2 " EF 1 6"Ø BL 2 BL 1 WH 1 MEDIA ROOM 001 PDR 002 SPORTS COURT 003 WORKOUT ROOM 009 SAUNA 008 STORAGE 007 GUEST BEDROOM 015 GUEST BATHROOM 016 STORAGE 011 LAUNDRY ROOM 005 MECHANICAL ROOM 012 ATRIUM 004 CORRIDOR 006 CORRIDOR 010 STAIR 014 CORRIDOR 013 UP UP UTILITY ROOM 017 1 2 3 4 5 6 20 " X 1 0 " ERV 1 ERV 1 ERV 1 14"X12" TYPE C TYPE C TYPE C GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 19-046 RE S I D E N C E 03/02/2020 PERMIT SET BCE BCE1 M1-1 BASEMENT LEVEL FLOOR PLAN 1 MECHANICAL - BASEMENT LEVEL FLOOR PLAN SCALE: 1/4" = 1'-0" MECHANICAL N 04/13/2020 07/29/2020 TF/JH FC 4 H 4 FC 1 H 1 250 CFM TYPE A 150 CFM TYPE A 150 CFM TYPE A 150 CFM TYPE A 150 CFM TYPE A 200 CFM TYPE A200 CFM TYPE A 200 CFM TYPE A 200 CFM TYPE A 50 CFM TYPE A 50 CFM TYPE A 200 CFM TYPE A 300 CFM TYPE B50 CFM TYPE A 20 " x 1 4 " 12"x8" 6"Ø 6"Ø 8"Ø 8"Ø 16 " x 1 2 " 6"Ø EF 1 6"Ø EF 1 6"Ø EF 1 6"Ø EF 2 1 2 3 4 5 6 GARAGE 116 MUDROOM 114 DN LAUNDRY ROOM 115 BALCONY 104 POWDER ROOM 107 MASTER BATHROOM 108 UP STAIR: 10" TREAD/7.75" RISER TOILET 109 CORRIDOR 110 CLOSET 112CLOSET 111 MASTER BEDROOM 113 CORRIDOR 106 ATRIUM 105 UP BALCONY 102 PACKAGE ROOM 101 ENTRY CLOSET 103 EF 1 6"Ø 20 " x 1 4 " 20"x14"20"x14" ERV 1 TYPE C 26" X 1 2 " 10"Ø 10"Ø 10"Ø 10"Ø 320 CFM TYPE B 320 CFM TYPE B 320 CFM TYPE B 320 CFM TYPE B 320 CFM TYPE B FC 6 H 6 20 " X 1 6 " 16"X10" 8" Ø 8" Ø 18"X12" 8" Ø 8" Ø 12 " X 1 2 " 200 CFM TYPE A CU 1 CU 2 CU 3 CU 4 CU 5 CU 6 16"x14" ERV 1 8" Ø M1-2 GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 19-046 RE S I D E N C E 03/02/2020 PERMIT SET BCE BCE1 GROUND LEVEL FLOOR PLAN 1 MECHANICAL - GROUND LEVEL FLOOR PLAN SCALE: 1/4" = 1'-0" MECHANICAL N 04/13/2020 07/29/2020 TF/JH 350 CFM300 CFM325 CFM TYPE B 75 CFM TYPE A 75 CFM TYPE A 75 CFM TYPE A 200 CFM TYPE A 200 CFM TYPE A 200 CFM TYPE A 200 CFM TYPE A 200 CFM TYPE A 125 CFM TYPE A 125 CFM TYPE A 250 CFM 250 CFM 250 CFM 200 CFM TYPE A 200 CFM TYPE A 18"X12" EF 1 6"Ø EF 1 6"Ø EF 1 6"Ø EF 1 6"Ø 1 2 3 4 5 6 BEDROOM 1 208 BEDROOM 2 212 BEDROOM 3 216 BATHROOM 1 209 BATHROOM 3 219 BATHROOM 2 213 DN UP CORRIDOR 210 CLOSET 211 CORRIDOR 214 CLOSET 215 CORRIDOR 217 CLOSET 218 CORRIDOR 220 LIVING ROOM 222 ENTRY 205 BAR 206 PDR 204 DINING ROOM 203 BALCONY 202 DECK 224 HOT TUB 223 CORRIDOR 221 CORRIDOR 207 PLANTER 225 KITCHEN 201 TYPE B TYPE B TYPE B TYPE B TYPE B TYPE C TYPE B TYPE B TYPE B TYPE B GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 19-046 RE S I D E N C E 03/02/2020 PERMIT SET BCE BCE1 M1-3 1 MECHANICAL - SECOND LEVEL FLOOR PLAN SCALE: 1/4" = 1'-0" MECHAICAL SECOND LEVEL FLOOR PLAN N 04/13/2020 07/29/2020 TF/JH ATTIC 301 DN 1 2 3 4 5 6 GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 19-046 RE S I D E N C E 03/02/2020 PERMIT SET BCE BCE1 M1-4 ATTIC LEVEL FLOOR PLAN 1 MECHANICAL - ATTIC LEVEL FLOOR PLAN SCALE: 1/4" = 1'-0" MECHANICAL N 04/13/2020 07/29/2020 TF/JH DOWNSPOUT DOWNSPOUT DOWNSPOUT INTERNAL ROOF DRAIN/ DOWNSPOUT 1 2 3 4 5 6 A B C D E GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 19-046 RE S I D E N C E 03/02/2020 PERMIT SET BCE BCE1 M1-5 ROOF PLAN 1 MECHANICAL - ROOF PLAN SCALE: 1/4" = 1'-0" MECHANICAL N 04/13/2020 07/29/2020 TF/JH (3) LOOP ZONE 1 238 FT/LOOP 1/2 GPM/LOOP (1) LOOP ZONE 2 212 FT/LOOP 1/2 GPM/LOOP (1) LOOP ZONE 3 163 FT/LOOP 1/2 GPM/LOOP (2) LOOP ZONE 4 173 FT/LOOP 1/2 GPM/LOOP (1) LOOP ZONE 5 168 FT/LOOP 1/2 GPM/LOOP (1) LOOP ZONE 6 246 FT/LOOP 1/2 GPM/LOOP MEDIA ROOM 001 PDR 002 SPORTS COURT 003 WORKOUT ROOM 009 SAUNA 008 STORAGE 007 GUEST BEDROOM 015 GUEST BATHROOM 016 STORAGE 011 LAUNDRY ROOM 005 MECHANICAL ROOM 012 ATRIUM 004 CORRIDOR 006 CORRIDOR 010 STAIR 014 CORRIDOR 013 UP UP UTILITY ROOM 017 1 2 3 4 5 6 GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 19-046 RE S I D E N C E 03/02/2020 PERMIT SET BCE BCE1 M2-1 BASEMENT LEVEL FLOOR PLAN 1 MECHANICAL - BASEMENT LEVEL FLOOR PLAN SCALE: 1/4" = 1'-0" MECHANICAL N 04/13/2020 07/29/2020 TF/JH (1) LOOP ZONE 7 74 FT/LOOP 1/2 GPM/LOOP (1) LOOP ZONE 8 226 FT/LOOP 1/2 GPM/LOOP (1) LOOP ZONE 9 158 FT/LOOP 1/2 GPM/LOOP (2) LOOP ZONE 10 228 FT/LOOP 1/2 GPM/LOOP (1) LOOP ZONE 11 202 FT/LOOP 1/2 GPM/LOOP (1) LOOP ZONE 12 152 FT/LOOP 1/2 GPM/LOOP (1) LOOP ZONE 13 61 FT/LOOP 1/2 GPM/LOOP (3) LOOP ZONE 14 227 FT/LOOP 1/2 GPM/LOOP 1 2 3 4 5 6 A B C D E GARAGE 116 MUDROOM 114 DN LAUNDRY ROOM 115 BALCONY 104 POWDER ROOM 107 MASTER BATHROOM 108 UP STAIR: 10" TREAD/7.75" RISER TOILET 109 CORRIDOR 110 CLOSET 112CLOSET 111 MASTER BEDROOM 113 CORRIDOR 106 ATRIUM 105 UP BALCONY 102 PACKAGE ROOM 101 ENTRY CLOSET 103 GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 19-046 RE S I D E N C E 03/02/2020 PERMIT SET BCE BCE1 M2-2 GROUND LEVEL FLOOR PLAN 1 MECHANICAL - GROUND LEVEL FLOOR PLAN SCALE: 1/4" = 1'-0" MECHANICAL N 04/13/2020 07/29/2020 TF/JH (1) LOOP ZONE 15 271 FT/LOOP 1/2 GPM/LOOP (2) LOOP ZONE 16 193 FT/LOOP 1/2 GPM/LOOP (3) LOOP ZONE 17 202 FT/LOOP 1/2 GPM/LOOP (5) LOOP ZONE 19 283 FT/LOOP 1/2 GPM/LOOP 1 2 3 4 5 6 A B C D E BEDROOM 1 208 BEDROOM 2 212 BEDROOM 3 216 BATHROOM 1 209 BATHROOM 3 219 BATHROOM 2 213 DN UP CORRIDOR 210 CLOSET 211 CORRIDOR 214 CLOSET 215 CORRIDOR 217 CLOSET 218 CORRIDOR 220 LIVING ROOM 222 ENTRY 205 BAR 206 PDR 204 DINING ROOM 203 BALCONY 202 DECK 224 HOT TUB 223 CORRIDOR 221 CORRIDOR 207 PLANTER 225 KITCHEN 201 GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 19-046 RE S I D E N C E 03/02/2020 PERMIT SET BCE BCE1 M2-3 1 MECHANICAL - SECOND LEVEL FLOOR PLAN SCALE: 1/4" = 1'-0" MECHAICAL SECOND LEVEL FLOOR PLAN N 04/13/2020 07/29/2020 TF/JH (1) LOOP ZONE 18 126 FT/LOOP 1/2 GPM/LOOP ATTIC 301 DN 1 2 3 4 5 6 GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 19-046 RE S I D E N C E 03/02/2020 PERMIT SET BCE BCE1 M2-4 ATTIC LEVEL FLOOR PLAN 1 MECHANICAL - ATTIC LEVEL FLOOR PLAN SCALE: 1/4" = 1'-0" MECHANICAL N 04/13/2020 07/29/2020 TF/JH GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 19-046 RE S I D E N C E 03/02/2020 PERMIT SET BCE BCE1 07/01/2020 CD REVIEW SET BCE BCE2 M3-1 DETAILS MECHANICAL MECHANICAL PROVISIONS 1. SCOPE OF WORK A. THE CONTRACTOR IS RESPONSIBLE FOR ALL WORK, MATERIALS, AND LABOR TO SATISFY A COMPLETE WORKING SYSTEM WHETHER SPECIFIED OR IMPLIED. B. ALL WORK IS TO BE PERFORMED IN STRICT COMPLIANCE WITH ALL LOCAL CODES AND ALL OTHER REGULATION GOVERNING WORK OF THIS NATURE. C. THE CONTRACTOR SHALL, BEFORE SUBMITTING ANY PROPOSAL, EXAMINE THE PROPOSED SITE AND SHALL DETERMINE FOR HIMSELF THE CONDITIONS THAT MAY EFFECT THE WORK. NO ALLOWANCE SHALL BE MADE IF THE CONTRACTOR FAILS TO MAKE SUCH EXAMINATIONS. D. ALL EQUIPMENT AND MATERIALS SHALL BE AS SPECIFIED OR "APPROVED EQUAL" BY THE ENGINEER OR ARCHITECT. 2. PERMITS A. THE CONTRACTOR SHALL SECURE ALL PERMITS OR APPLICATIONS AND PAY ANY AND ALL FEES. 3. SHOP DRAWINGS A. SUBMIT MATERIAL LIST AND SHOP DRAWINGS FOR MAJOR EQUIPMENT TO THE ACHITECT/ENGINEER FOR APPROVAL. THE CONTRACTOR SHALL SUBMIT ELECTRONIC SHOP DRAWINGS AND THEY SHALL BE CLEARLY LABELED. 4. FLEXIBLE DUCT WORK - SUPPORT/HANG DUCTS ABOVE CEILING INSULATION, TYP. A. FLEXIBLE TYPE DUCT SHALL BE OF TWO ELEMENT SPIRAL CONSTRUCTION COMPOSED OF A CORROSION RESISTANT METAL SUPPORTING SPIRAL AND COATED FABRIC WITH A MINERIAL BASE. FLEXIBLE DUCT CONNECTORS SHALL BE LISTED BY U.L., CLASS 1 DUCTS, AND SHALL HAVE A FLAME SPREAD RATING NOT EXCEEDING 25 AND A SMOKE DEVELOPED RATING NOT EXCEEDING 50. B. USE OF FLEXIBLE DUCTWORK SHALL BE LIMITED TO NO MORE THAN 6 LINEAR FEET PER RUN. C. CONTRACTOR SHALL BE CAREFUL SO AS NOT TO KINK OR COLLAPSE FLEXIBLE DUCT. 5. REFRIGERENT A. PIPING CONTRACTOR SHALL PROVIDE AND INSTALL REFRIGERANT PIPING IN ACCORDANCE WITH THE MANUFACTURER'S REC0MMENDATIONS AND IN SUCH A WAY AS TO BE INCONSPICIOUS AND FREE FROM ANY POSSIBLE CONDENSATION. B. INSULATE REFRIGERANT LINES WITH ARMOUR-FLEX TYPE INSULATION, SHALL BE TYPE "K" COPPER TUBING, WITH WROUGHT COPPER SOLDER TYPE FITTINGS SUITABLE FOR CONNECTION WITH SILVER SOLDER. 6. DUCTWORK A. THE DUCTWORK SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE "SMACNA" APPLICABLE MANUALS. B. ALL DUCTWORK SHALL BE THE LOW VELOCITY TYPE, UNLESS SPECIFIED OTHERWISE. C. CONTRACTOR SHALL PROVIDE AND INSTALL APPROVED FIRE DAMPERS AND ACCESS PANELS IN ANY AND ALL DUCTWORK WHICH PENETRATES A HORIZONTAL OR VERTICAL FIRE PARTITION, OR AS OTHERWISE SHOWN ON DRAWINGS. D. ALL BRANCH DUCTS TO HAVE VOLUME DAMPERS, SMOOTH TURN RADIUS DUCTWORK OR TURNING VANES SHALL BE USED THROUGHOUT WHERE FLOW EXCEEDS 150 CFM. E. ALL DUCT JOINTS TO BE SEALED IN ACCORDANCE WITH "SMACNA" STANDARDS AND ACCEPTED GOOD PRACTICE. F. ALL DUCT DIMENSIONS SHOWN ARE NET OPEN INSIDE VALUES. DIMENSIONS MAY BE CHANGED SO LONG AS THE NET FREE FACE AREA IS MAINTAINED G. ALL CONCEALED DUCTWORK SHALL BE INSULATED WITH 1-1/2" FIBERGLASS INSULATING BLANKET WITH ALUMINUM FOIL FACING OR 1-1/2" LINER. ALL SEAMS SEALED. H. ALL SUPPLY AND RETURN DUCTWORK 15 FEET DOWNSTREAM OF THE HVAC UNIT SHALL BE INTERNALLY LINED WITH A 1/2" ACOUSTICAL DUCT LINER UNLESS OTHERWISE NOTED ON THE DRAWINGS. 7. DRAINAGE PIPING A. (CONDENSATE) SHALL BE SCHEDULE 40 PVC PIPE WITH SOLVENT JOINTS. PITCH HORIZONTAL LINES 1" IN 10'-0". CONDENSATE DRAINS SHALL BE ROUTED TO FLOOR DRAIN, ROOF DRAIN OR INDIRECT WASTE DRAIN. 8. HVAC CONTROLS A. CONTRACTOR TO SUPPLY AND INSTALL ALL CONTROL WIRING AND THERMOSTATS AS REQUIRED. 9. ELECTRICAL A. CONTRACTOR TO COORDINATE WITH ELECTRICAL CONTRACTOR FOR LOCATION OF WIRING FOR EACH HVAC UNIT. 10. PIPE SUPPORTS A. ALL PIPE SHALL BE SUPPORTED FROM THE BUILDING STRUCTURE IN A NEAT AND WORKMANLIKE MANNER. THE USE OF WIRE OR METAL STRAP TO SUPPORT PIPES WILL NOT BE PERMITTED. SPACING OF PIPE SUPPORTS SHALL NOT EXCEED 8 FEET FOR ALL PIPING. PLASTIC PIPING TO BE SUPPORTED EVERY 4 FEET. 11. GAS PIPING A. PIPING SHALL BE SCHEDULE 40 BLACK STEEL PIPE WITH MALLEABLE IRON FITTINGS. WHERE GAS PIPE CONNECTS TO EQUIPMENT, IT SHALL BE PROVIDED WITH A DRIP LEG THE FULL SIZE OF THE RUNOUT, A 100% SHUT-OFF VALVE AND A UNION. GAS PIPING CONTAINING PRESSURE GREATER THAN 9" W.G. SHALL BE SCHEDULE 40 BLACK STEEL PIPE WITH WELDED JOINTS. 12. MISCELLANEOUS A. ALL EXTERIOR OPENINGS TO BE PROPERLY CAULKED AND SEALED WITH A SEALANT OF HIGH QUALITY AND LONG LIFE, TO PREVENT INFILTRATION OF OUTSIDE AIR INTO CONDITIONED SPACE. COORDINATE INSTALLATION OF ALL ROOF FLASHING AT ROOF PENETRATION. B. DO NOT SCALE THIS DRAWING FOR EXACT DIMENSIONS. C. VERIFY ALL FIGURES, CONDITIONS, AND DIMENSIONS AT THE JOB SITE. D. THE MECHANICAL PLANS ARE INTENDED TO BE DIAGRAMMATIC AND ARE BASED ON ONE MANUFACTURE'S EQUIPMENT. THEY ARE NOT INTENDED TO SHOW EVERY ITEM IN ITS EXACT LOCATION, THE EXACT DIMENSIONS, OR ALL THE DETAILS OF THE EQUIPMENT. E. THE CONTRACTOR SHALL VERIFY THE ACTUAL DIMENSIONS OF THE EQUIPMENT PROPOSED TO ENSURE THAT THE EQUIPMENT WILL FIT IN THE AVAILABLE SPACE. 13. TESTING AND BALANCING A. THE HVAC SYSTEM SHALL BE TESTED AND AND BALANCED BY AN INDEPENDENT AGENCY, UNDER THE SUPERVISION OF A LICENSED PROFESSIONAL ENGINEER. A SEALED TYPE WRITTEN REPORT SHALL BE SUBMITTED TO THE ARCHITECT/ENGINEER FOR REVIEW AND APPROVAL. 14. GUARANTEE A. MATERIALS, EQUIPMENT AND INSTALLATION SHALL BE GUARANTEED FOR A PERIOD OF ONE(1) YEAR FROM DATE OF ACCEPTANCE. DEFECTS WHICH APPEAR DURING THAT PERIOD SHALL BE CORRECTED AT THIS CONTRACTOR'S EXPENSE. B. FOR THE SAME PERIOD, THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO PREMISES CAUSED BY DEFECTS IN WORKMANSHIP OR IN THE WORK OR EQUIPMENT FURNISHED AND/OR INSTALLED BY HIM. EXHAUST FAN SCHEDULE EQUIPMENT NO.SERVICE LOCATION CFM EXTERNAL STATIC PRESS (IN. W.G.) MOTOR MANUFACTURER & MODEL OPTIONS/ACCESSORIES WATTS HP RPM VOLT/PH/HZ EF-1 RESTROOM CEILING MOUNTED 75 0.25 10.20 -###120/1/60 PANASONIC FV-05-11VK1 NOTE-1 EF-2 GARAGE CEILING MOUNTED 200 0.2 59.00 -###120/1/60 COOK GC-186 NOTE-1 NOTES: 1. PROVIDE WITH MOTOR STARTER, POWER DISCONNECT, AND BELT DRIVEN VFD MOTOR. FAN COIL SCHEDULE EQUIPMENT NO.SERVICE SUPPLY AIR (CFM) OUTSIDE AIR (CFM) SUPPLY AIR E.S.P. (IN. W.G.) COOLING HOT WATER HEATING COIL FILTERS SUPPLY FAN (HP) ELECTRICAL UNIT WEIGHT (LBS.) MANUFACTURER & MODEL OPTIONS /ACCESSORIESNOM. (TONS) OUTPUT (MBH) FLOW (GPM) EWT (°F) (MBH) V./PH./HZ.MCA MOCP FC-1 GYM 1,600 300 1.5 4 60 4.0 140 2" TA 0.5 120/1/60 10.2 15 165 LENNOX - CBWMV036 NOTE-1 FC-2 BASEMENT 1,400 1.5 3 48 3.2 140 2" TA 0.5 120/1/60 10.2 15 165 LENNOX - CBWMV060 NOTE-1 FC-3 MASTER 1,900 1.5 4 53 3.5 140 2" TA 0.5 120/1/60 10.2 15 165 LENNOX - CBWMV060 NOTE-1 FC-4 GROUND LEVEL 1,350 1.5 3 46 3.1 140 2" TA 0.5 120/1/60 10.2 15 165 LENNOX - CBWMV060 NOTE-1 FC-5 ENTRY 1,350 1.5 3 15 1.0 140 2" TA 0.5 120/1/60 10.2 15 165 LENNOX - CBWMV036 NOTE-1 FC-6 FLOOR 2 2,000 1.5 5 150 10.0 140 2" TA 0.5 120/1/60 10.2 15 165 LENNOX - CBWMV036 NOTE-1 NOTES: 1. PROVIDE WITH FILTERS AND RACK, DX COOLING COIL, HOT WATER HEATING COIL, POWER DISCONNECT, FLEX DUCT CONNECTION, VIBRATION ISOLATION HANGING KIT AND REMOTE MOUNTED THERMOSTAT. BOILER SCHEDULE EQUIPMENT NO.SERVICE INPUT CAPACITY (BTU/HR.) OUTPUT CAPACITY (BTU/HR.) BOILER VOLUME (GALLONS) FLUE/COMB. AIR SIZE (INCHES) ELECTRICAL MANUFACTURER & MODEL OPTIONS/ACCESSORIES AMPS V./PH./HZ. BL-1 DOMESTIC/ RADIANT 500 394 5 4 120/1/60 LOCHINVAR KBN501 NOTE-1 BL-2 DOMESTIC/ RADIANT 500 394 5 4 120/1/60 LOCHINVAR KBN501 NOTE-1 NOTES: 1. PROVIDE WITH ASME RELIEF VALVE, CSD-1 CONTROLS, CONCENTRIC VENT KIT, LOW-WATER CUTOFF WITH MANUAL RESET & TEST, FLOW SWITCH, ADJUSTABLE HIGH LIMIIT WITH MANUAL RESET, MODULATING TEMPERATURE CONTROL, CONDENSATE NEUTRALIZING KIT, HIGH ALTITUDE KIT SIZED PER LOCATION ELEVATION, AND BLOWER MOTOR. HUMIDIFIER SCHEDULE EQUIPMENT NO.SERVICE LOCATION OUTPUT (LBS./HR.)AMPS V/PH/HZ MANUFACTURER & MODEL OPTIONS/ACCESSORIES H-1 (5)FC-1,2,3,4,6 DUCT 5 20 120/1/60 NORTEC RH2+NOTE-1 NOTES: 1. PROVIDE WITH EACH HUMIDIFIER DUCT MOUNTED HUMIDISTAT, OUTDOOR AIR RESET HIGH LIMIT SWITCH DRAIN PAN STEAM TUBE WITH SAM MANIFOLD, CONDESATE TUBE, DRAIN, POWER DISCONNECT, ETC. PUMP SCHEDULE EQUIPMENT NO.SERVICE LOCATION GPM HEAD (FT.)MANUFACTURER & MODEL OPTIONS/ACCESSORIES RPM V./PH./HZ.HP FLA RCP-1 DOMESTIC WATER RECIRC MECH. RM 5 25 VARIABLE 230/1/60 0.33 2 TACO 0012 NOTE-5 CP-2 BOILER MECH. RM 58 50 VARIABLE 115/1/60 1.50 2 TACO VR25 NOTE-1 CP-3 SNOWMELT MECH. RM 80 15 VARIABLE 115/1/60 2.2 6 TACO VR30 NOTE-2 CP-4 RADIANT CIRCULATION MECH. RM.17 30 VARIABLE 115/1/60 0.68 1 TACO VR15 NOTE-3 CP-5 FAN COIL MECH. RM 25 30 VARIABLE 115/1/60 1.50 6 TACO VR25 NOTE-4 CP-6 BOILER LOOP MECH. RM.110 30 VARIABLE 115/1/60 2.20 8 TACO VR30 NOTE-4 CP-7 DOM. WATER .MECH. RM.14 30 VARIABLE 115/1/60 0.68 2 TACO VR15 NOTE-5 CP-8 RADIANT INJECTION PUMP MECH. RM.2.5 30 VARIABLE 115/1/60 0.68 2 TACO VR15 NOTE-6 NOTES: 1. PROVIDE WITH CAST IRON CASING, POWER DISCONNECT, MOTOR STARTER, COMPOSITE (PES) IMPELLER, FLANGED CONNNECTIONS AND 3-SPEED MOTOR. MOTOR HORSEPOWER SHALL BE GREATER THAN NON-OVERLOADING BRAKE HORSEPOWER. 2. PROVIDE WITH CAST IRON CASING, POWER DISCONNECT, MOTOR STARTER, STAINLESS STEEL IMPELLER, FLANGED CONNNECTIONS AND 3-SPEED MOTOR. MOTOR HORSEPOWER SHALL BE GREATER THAN NON-OVERLOADING BRAKE HORSEPOWER. 3. PROVIDE WITH ECM MOTOR, MOTOR STARTER, FIBERGLASS REINFORCED PPS IMPELLER, STAINLESS STEEL SHAFT, METAL IMPREGNATED CARBON, CAST IRON VOLUTE, POWER DISCONNECT, REQUIRED MINIMUM INLET PRESSURE AT TEMPERATURE. 4. PROVIDE WITH CAST IRON CASING, ECM MOTOR, POWER DISCONNECT, MOTOR STARTER, STAINLESS STEEL IMPELLER, STAINLESS STEEL SHAFT, IMPREGNATED CARBON METAL BEARING, FLANGED CONNECTIONS. MOTOR HORSEPOWER SHALL BE GREATER THAN NON-OVERLOADING BRAKE HORSEPOWER. 5. PROVIDE WITH STAINLESS STEEL CASING, POWER DISCONNECT, MOTOR STARTER, NON METALLIC IMPELLER, CERAMIC SHAFT, CARBON BEARING, FLANGED CONNECTIONS, INTEGRAL FLOW CHECK VALVE. MOTOR HORSEPOWER SHALL BE GREATER THAN NON-OVERLOADING BRAKE HORSEPOWER. 6. PROVIDE WITH POWER DISCONNECT, NON METALLIC IMPELLER, FLANGED CONNECTIONS, INSTALL PER MANUFACTURER'S INSTRUCTIONS/RECOMMENDATIONS. INDIRECT WATER HEATER SCHEDULE EQUIPMENT NO CAPACITY RECOVERY @100 DEG F. RISE BTU PER HR.BOILER CONNECTION WATER CONNECTION MANUFACTURER & MODEL OPTIONS/ACCESSORIES WH-1 119 308 199,999 1"1-1/2"LOCHINVAR SIT 119 NOTE-1 NOTES: 1. PROVIDE WITH ISOLATION VALVES. GRILLE-REGISTER-DIFFUSER SCHEDULE EQUIPMENT NO.SIZE MODEL MANUFACTURER FINISH OPTIONS/ACCESSORIES A 3"X36"1500 KRUEGER TBD NOTE-1 B 3"X60"1500 KRUEGER TBD NOTE-1 C 24"X24"S80P KRUEGER TBD NOTE-2 NOTES: 1. INSTALL WITH BALANCING DAMPER, COORDINATE MODEL WITH MOUNTING TYPE. 2. COORDINATE MOUNTING TYPE WITH SURFACE. ENERGY RECOVER VENTILATOR SCHEDULE EQUIPMENT NO.SERVICE LOCATION SUPPLY CFM TEMPERATURE E.S.P (IN W.G.) SUPPLY FAN E.S.P. (IN W.G.)EXHAUST CFM EXHAUST FAN MANUFACTURER & MODEL OPTIONS/ACCESSORIES E.A.T L.A.T HP TYPE:V./PH./HZ.HP TYPE:V./PH./HZ. ERV-1(3)FAN COILS RETURN DUCTS 120 -5 60 0.25 -VFD 120/1/60 0.25 120 -VFD 120/1/60 RENEWAIRE BR130 NOTE-1 NOTES: 1. PROVIDE WITH RETURN AIR THERMOSTAT, INTERNALLY MOUNTED CONTROL CENTER SENSORS, MOTOR STARTER, CONTROL TRANSFORMER, HANGERS AND RUBBER IN SHEAR VIBRATION ISOLATORS, DOUBLE WALL CONSTRUCTION, FILTERS ON THE OUTSIDE AIR INTAKE, DEFROST PREHEATER, DUCT FLANGES, AND CONVENIENCE OUTLETS. UNIT SHALL OPERATE 25% OF THE TIME AND EXCEEDS LOCAL OUTSIDE AIR REQUIREMENTS. DUCTWORK ROUTING CORDINATION TO EXTERIOR AT DIGRESSION OF CONTRACTOR AIR COOLED CONDENSING UNIT SCHEDULE EQUIPMENT NO.SERVICE NOMINAL COOLING CAPACITY (TON) REFRIG. PIPING ELECTRIC MANUFACTURER & MODEL OPTIONS/ACESSORIES LIQUID VAPOR V/PH/HZ MOCP (A)MCA (A) CU-1 FC-1 4 3/8"7/8"230/1/60 29 50 LENNOX - XC20 NOTE-1 CU-2 FC-2 3 3/8"7/8"230/1/60 29 50 LENNOX - XC20 NOTE-1 CU-3 FC-3 4 3/8"7/8"230/1/60 29 50 LENNOX - XC20 NOTE-1 CU-4 FC-4 3 3/8"7/8"230/1/60 29 50 LENNOX - XC20 NOTE-1 CU-5 FC-5 3 3/8"3/4"230/1/60 29 50 LENNOX - XC20 NOTE-1 CU-6 FC-6 5 3/8"1-1/8"230/1/60 29 50 LENNOX - XC20 NOTE-1 NOTES: 1. PROVIDE LINE SET AS RECOMMENDED BY MANUFACTURER, POWER DISCONNECT, HOUSEKEEPING PAD AND ISOLATION VALVES. 07/29/2020 TF/JH GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 19-046 RE S I D E N C E 03/02/2020 PERMIT SET BCE BCE1 M3-2 DETAILS MECHANICAL SUBFLOOR WIRSBO 1 1/4" STAPLE WIRSBO TUBING POURED FLOOR UNDERLAYMENT ON A SUSPENDED WOOD FLOOR POURED UNDERLAYMENT SUITABLE INSULATION N.T.S. FLOOR JOIST OVER A SAND BED N.T.S. SLAB ON OR BELOW GRADE SAND/SOIL WIRSBO TUBINGWIRE TIE BASE MATERIAL OR EQUAL INSULATION CONCRETE SLAB WIRE MESH, REBAR OR STAPLE TO RIGID FOAM SLAB SHIELD OR WIRSBO TUBING SLAB SHIELD EQUAL INSULATION GENERAL TUBING NOTES: SNOWMELT TUBING IS 5/8" HEATPEX SPACING IS 10" OC TEMPERATURE DROP=30°F SUPPLY=140°F DENSITY=140 BTUH/FT2 SURFACE TEMPERATURE=37°F SOLUTION IS 50% PG. PROVIDE A MINIMUM R-10 INSULATION UNDER SNOWMELT SLAB. RADIANT FLOOR TUBING IS 1/2" HEATPEX SPACING IS 10" OC SUPPLY=105°F TEMPERATURE DROP=13° SOLUTION IS WATER. INSTALL TUBING UNDER FIREPLACES, TUBS AND SHOWERS AS SHOWN ON THE FLOOR PLANS. SEE DETAILS FOR RECOMMENDED TUBING PRACTICES. PROVIDE A MINIMUM R-5 INSULATION UNDER RADIANT FLOOR SLAB. BUILDING HEATING BOILER PIPING DETAIL SCALE: NTS NOTE: FINAL FILL OF SYSTEM SHALL BE WITH SOLUTION OF 30% PROPYLENE GLYCOL. TYPICAL CONDENSATE DRAIN ~ THERMOMETER 1 1/2" HWS AMTROL EXPANSION TANK ~ DOMESTIC COLD WATER 1 1/2" T115° HWR TACO AIR VENT PRESSURE 1/2" HWS EXPANSION TANK TO DRAIN 4" 1-1/2" AXIOM #MF300 GLYCOL FEEDER STRAINER ~ ~ TO FAN COILS 25 GPM DRAIN 3/4" ANTI-SCALDING VALVE SUPPLY SENSOR 3/4" RADIANT MIXING BLOCK INJECTOR PUMP WITH OUTDOOR SENSOR, BOILER SENSOR, RADIANT SENSOR. INJECTION FLOW= 2.5 GPM. SYSTEM CIRCULATION FLOW=16.5 GPM, 108 MBH. S S S OUTDOOR SENSOR 105° 92° RADIANT MAINFOLD RADIANT LOOP, TYPICAL RADIANT MAINFOLD RADIANT LOOP, TYPICAL 2" 2" GPM14 GPM 4" GAUGE 4"12" MAX. S RADIANT MAINFOLD RADIANT LOOP, TYPICAL 1-1/2" 2" TACO - CBX300-125 1-1/2" 2" G G HWS MIXING BLOCK RADIANT (INSTALL PER MANUFACTURERS RECOMMENDATION) 3" DOMESTIC HOT WATER HWS G HWR G G G PIPE RELIEF DRAIN FULL SIZE TO FLOOR DRAIN G 2" G HWR 4" 4"TACO 3" AIR SEPARATOR TACO AIR VENT 3" 3" 4" 3/4" TO NATURAL GAS SOURCE 2" T SNOWMELT MANIFOLD SNOWMELT LOOP, TYPICAL TACO HEAT EXCHANGER 1000 MBH. HOT SIDE FLOW= 80 GPM, 30% GLYCOL COLD SIDE FLOW= 86 GPM, 50% GLYCOL S 120° 90° MODEL TB120Tx80 OR EQUAL SNOWMELT MANIFOLD TACO AIR VENT 1/2" EXPANSION TANK TO DRAIN SNOWMELT LOOP, TYPICAL SNOWMELT MANIFOLD SNOWMELT LOOP, TYPICAL TACO - CBX30-125 TACO 2" AIR SEPARATOR SNOWMELT SENSOR 3" 2" TACO AIR VENT 3" SEQUENCE OF OPERATION: ON A CALL FOR HEATING FROM ANY ZONE THERMOSTAT THE BOILER CONTROL SYSTEM SHALL BE ENABLED TO FIRE AND SEQUENCE THE BOILERS. AT THE SAME TIME, THE PUMP CP-4 AND CP-8 WILL RECEIVE A DEMAND SIGNAL WHICH WILL ALLOW IT TO START OPERATION AND MAINTAIN RADIANT FLOOR SET POINT TEMPERATURE (ADJ). CP-5 SHALL RECEIVE A DEMAND SIGNAL WHICH WILL ALLOW IT TO START OPERATION AND MAINTAIN FAN COIL TEMPERATURE. CP-3 AND CP-6 SHALL RECEIVE A DEMAND SIGNAL WHICH WILL ALLOW IT TO START OPERATION AND MAINTAIN SNOWMELT TEMPERATURE. THE BOILER CONTROL SYSTEM SHALL CONTROL THE FIRING AND SEQUENCING OF THE BOILERS. THE CONTROLS SHALL MONITOR OUTSIDE AIR, HOT WATER SUPPLY AND HOT WATER RETURN TEMPERATURES. THE BOILER CONTROLS SHALL START/STOP THE INDIVIDUAL BOILER CIRCULATION PUMPS CP-2. ON A CALL FOR DOMESTIC WATER HEATING, THE PUMP CP-7 SHALL BE STARTED AND A DOMESTIC HOT WATER HEATING DEMAND SIGNAL SHALL BE SENT TO THE BOILER CONTROL SYSTEM. THIS WILL ALLOW THE BOILERS TO FIRE TO MAINTAIN DOMESTIC WATER HEATING PRIORITY. PUMP CP-7 SHALL RUN CONTINUOUSLY. WALL MOUNTED ZONE THERMOSTATS SHALL CONTROL ZONE VALVES AT EACH ZONE MANIFOLD TO MAINTAIN SPACE TEMPERATURE. 04/13/2020 07/29/2020 TF/JH GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 19-046 RE S I D E N C E 03/02/2020 PERMIT SET BCE BCE1 M3-3 DETAILS MECHANICAL - SIDEWALL DISCHARGE BATHROOM EXHAUST FAN DETAIL N.T.S. AIREX H A U S T GRILLE CEILING FAN CABINET ABOVE EXHAUST DAMPER W/ BACKDRAFT WALL CAP DUCT CEILING FLOOR OR ROOF EF CONNECTION REFRIGERANT GAUGE CONTROL CONDUIT - POWER AND REFRIGERANT LIQUID LINE INDICATOR SIGHT GLASS WITH MOISTURE WITH INSULATION REFRIGERANT SUCTION LINE VALVE BACK-SEATED REFRIGERANT CONDENSING UNIT - SLAB MOUNTED AT GRADE AIR-COOLED CONDENSING UNIT N.T.S. FILTER-DRYER FAN GUARD AIR HANDLING UNIT OR AIR CONDITIONING UNIT ADAPTOR SECTION DRAIN PAN COOLING COIL 4" * DRAIN PLUG MIMIMUM SIZE 1". ABOVE 1" FULL SIZE ON UNIT CONNECTION. TO CONDENSATE PUMP EXTEND FULL SIZE. NOT TO SCALE CONDENSATE DRAIN DETAIL FLAT ROOF CAP ROOF FLASHING ROOF EXHAUST DUCT CEILING/ROOF FRAMING EXHAUST FAN CEILING GRILLECEILING ROOF CURB 1' - 6 " MI N . CEILING EXHAUST FAN DETAIL NOT TO SCALE EXHAUST DUCT 1 1 / 2 W USE THIS DESIGN WHERE ROUND 90 ELS ARE SHOWN ON PLANS ROUND 90 ELBOW CL LC CONSTRUCTION OF 90 ELBOWS "W" "W " "W " "W" TURN VANES-SEE DETAIL THIS SHEET USE THIS DESIGN WHERE SQUARE 90 ELS ARE SHOWN ON PLANS OR IF SPACE CONDITIONS DO NOT PERMIT INSTALLATION OF ROUND 90 ELLS SQUARE 90 ELBOW "W" "W"" W " "W" CL LC USE THIS DESIGN WHERE ROUND 45 ELBOWS ARE SHOWN ON PLANS 1 1/ 2 W TURN VANES-SEE DETAIL THIS SHEET ON PLANS ELBOWS ARE SHOWN WHERE ROUND 45 USE THIS DESIGN SQUARE 45 ELBOW CONSTRUCTION OF 45 ELBOWS ROUND 45 ELBOW AIR FLOW "W" "W" BRANCH MAIN ROUND BRANCH TAKEOFF SQUARE BRANCH TAKEOFF MAIN BRANCH FLOW AIR CONSTRUCTION OF BRANCH TAKEOFFS FROM MAIN TURN VANES-SEE DETAIL THIS SHEET SLOPE NOT TO EXCEED 1" IN 4" TYPICAL RECTANGULAR TRANSITION TYPICAL RECTANGULAR TO ROUND TRANSITION 1" IN 4" SLOPE NOT TO EXCEED RECTANGULAR DUCT ROUND DUCT AIR FLOW MAIN SPLITTER DAMPER TURN VANES BRANCH DAMPER ADJUSTMENT ROD & LOCK SCREW TYPICAL SPLITTER DAMPER DETAILS OF THE LOW VELOCITY DUCT LAYOUT NO SCALE 1"R . 2" R A D I U S 1" 1" 1" 1 " DETAIL OF TURN VANES CONNECTION LINKAGE DOUBLE ACTING BLADES TYPICAL VOLUME DAMPER HINGE POINT OPERATING SHAFT FOR QUADRANT OR MOTOR. ROOF CLAMP FLASING 12" MINIMUM ABOVE AVERAGE SNOW ACCUMLATION COMBUSTION AIR PIPEFLUE EXHAUST PIPE CONCENTRIC FLAT ROOF TERMINATION INSTALLATION DETAIL (TYPICAL FOR HIGH EFFICIENCY GAS FURNACES) N.T.S. D R A I N V E N T H W R E T U R N L I Q U I D L I N E L I N E S U C T I O N ATTACHED HOT WATER COIL DETAIL HORIZONTAL FAN COIL UNIT WITH N.T.S. H O T W A T E R C O I L S U P P L Y D R A I N T O O U T S I D E O R F L O O R 3 / 4 " P V C D R A I N F C PAN F C R O O F R A F T E R S R O D T O H A N G E R C O N N E C T I O N F L E X I B L E R E T U R N DRIP R E F R I G . R E F R I G . F A N C O I L U N I T H W S U P P L Y FROM GAS SUPPLY FROM GAS SUPPLY 6" TRAP (DRIP LEG) TO EQUIPMENT/ CONTROLS GROUND JOINT UNION MANUAL SHUT-OFF VALVE WITH AN 1/8" N.P.T. PLUGGED TAPPING ACCESSIBLE FOR TEST GAGE CONNECTION TO BE INSTALLED UPSTREAM OF THE GAS SUPPLY CONNECTION TO THE APPLIANCE. GAS COCK GAS CONNECTION TO EQUIPMENT DETAIL NOT TO SCALE GRADE GRADE FINISHED ABOVE 18" MIN. EXHAUST AIR INTAKE AIR AIR INTAKE WALL OUTSIDE CLAMP BUSHING REDUCING ELBOW AIR EXHAUST AIR INTAKE CONCENTRIC WALL TERMINATION INSTALLATION DETAIL (TYPICAL FOR HIGH EFFICIENCY GAS FURNACES) N.T.S. N.T.S. (TYPICAL FOR HIGH EFFICIENCY GAS FURNACES) TERMINATION INSTALLATION DETAIL CONCENTRIC SLOPED ROOF FLUE EXHAUST PIPE COMBUSTION AIR PIPE SNOW ACCUMLATION ABOVE AVERAGE 12" MINIMUM ROOF PITCHED FLASING SHEET METAL STRAP CLAMP 8" CONCRETE BLOCK PROVIDE LINTEL OVER LOUVER AS SHOWN ON ARCHITECTURAL DWG. NOT TO SCALE EXPOSED LINKAGE CAULK & SEAL ALL AROUND ADJUSTABLE INTAKE/EXHAUST LOUVER BIRD SCREEN MOTORIZED LOUVER DETAIL MOTORIZED ACTUATOR EXTERIOR WALL REDUCER 6"X4" PVC STONE CRUSHED EARTH 4" 6 MIL. VAPOR BARRIER CONCRETE SLAB GROUND FLOOR PVC 4" SCH. 40 12 " ROOF SLAB, VAPOR BARRIER, AND CRUSHED STONE. 1. REFERENCE ARCHITECTURAL DRAWINGS FOR DETAILS OF NOTE: NOT TO SCALE RADON VENT DETAIL EXHAUST FAN: EQUIVALENT TO FANTECH - RN3 INLINE RADON FAN 2. EXHAUST FAN TO RUN CONTINUOUSLY PVC 4" SCH. 40 MINIMUM 3"Ø PERFORATED PIPING INSTALLED DIRECTLY IN AGGREGATE TO CREATE LOOP AS SHOWN ON PLUMBING DRAWINGS RECOMMENDED PRODUCT ADS SINGLE WALL CORRUGATED, PERFORATED PIPING 120V/1PH/60HZ, 141 WATTS, 2 AMPS, 1.42 E.S.P., 377 CFM, 2782 RPM FAN SHALL RUN CONTINUOUSLY, PROVIDE WITH POWER DISCONNECT 04/13/2020 07/29/2020 TF/JH