HomeMy WebLinkAboutFile Documents.617 W Bleeker St.0062-2019-BRES (26)FC
5
H
5
FC
2
H
2
FC
3
H
3
EF
1
6"Ø
150 CFM
TYPE A
150 CFM
TYPE A
150 CFM
TYPE A
150 CFM
TYPE A
150 CFM
TYPE A
150 CFM
TYPE A
150 CFM
TYPE A
150 CFM
TYPE A
150 CFM
TYPE A 150 CFM
TYPE A
150 CFM
TYPE A
10"Ø
8"
Ø
12"X8"
8"
Ø
8"
Ø
12"X12"
1
0
"
X
8
"
10"X8"
2
4
"
X
1
4
"
1
6
"
X
1
0
"
20"X12"
8"Ø
8"Ø
8"Ø
8"Ø
24"X14"6"Ø
6"Ø
8"Ø
1
0
"
X
8
"
50 CFM
TYPE A
10
"
X
1
0
"
10"X10"
10"X10"
8"
Ø
8"
Ø
8"
Ø
8"
Ø
8"
Ø
20
"
X
1
0
"
8"
Ø
8"
Ø
8"
Ø
8"
Ø
8"
Ø
8"
Ø
6"
Ø
8"
Ø
8"
Ø
10
"
Ø
6"Ø
14
"
X
1
2
"
EF
1 6"Ø
BL
2
BL
1 WH
1
MEDIA ROOM
001
PDR
002
SPORTS COURT
003
WORKOUT ROOM
009
SAUNA
008
STORAGE
007
GUEST BEDROOM
015
GUEST
BATHROOM
016
STORAGE
011
LAUNDRY ROOM
005
MECHANICAL ROOM
012
ATRIUM
004
CORRIDOR
006
CORRIDOR
010
STAIR
014
CORRIDOR
013
UP
UP
UTILITY ROOM
017
1
2
3
4
5
6
20
"
X
1
0
"
ERV
1
ERV
1
ERV
1
14"X12"
TYPE C
TYPE C
TYPE C
GENERAL CONTRACTOR
Janckila Construction Inc.
75 Buckskin Drive
Carbondale, CO 81623
T 970.963.7239
F 970.963.7239
STRUCTURAL ENGINEER
Albright and Associates
402 Park Ave., Unit A
Basalt, CO 81621
T 970.927.4363
CIVIL ENGINEER
Roaring Fork Engineering
592 Highway 133,
Carbondale, CO 81623
T 970.948.7474
MEP ENGINEER
Bighorn Consulting Enginners, Inc.
386 Indian Road
Grand Junction, CO 81501
T 970.241.8709
ACOUSTIC CONSULTANT
Acentech
33 Moulton Street
Cambridge, MA 02138
T 617.499.8000
F 617.499.8074
61
7
W
E
S
T
B
L
E
E
K
E
R
S
T
R
E
E
T
AS
P
E
N
AS
P
E
N
,
C
O
8
1
6
1
1
Drawing Title:
Drawing No:
Phase:
Architect
29 Stanhope Street
3rd Floor
Boston, MA 02116
T 617.426.0995
F 617.426.0998
MONICA PONCE DE LEON
STUDIO, INC.
DATE & ISSUE DESCRIPTION BY CHECK
ISSUE/
REVISION
Project Number:
19-046
RE
S
I
D
E
N
C
E
03/02/2020 PERMIT SET BCE BCE1
M1-1
BASEMENT LEVEL FLOOR PLAN
1 MECHANICAL - BASEMENT LEVEL FLOOR PLAN
SCALE: 1/4" = 1'-0"
MECHANICAL
N
04/13/2020
07/29/2020
TF/JH
FC
4
H
4
FC
1
H
1
250 CFM
TYPE A
150 CFM
TYPE A
150 CFM
TYPE A
150 CFM
TYPE A
150 CFM
TYPE A
200 CFM
TYPE A200 CFM
TYPE A
200 CFM
TYPE A
200 CFM
TYPE A
50 CFM
TYPE A
50 CFM
TYPE A
200 CFM
TYPE A
300 CFM
TYPE B50 CFM
TYPE A
20
"
x
1
4
"
12"x8"
6"Ø
6"Ø
8"Ø
8"Ø
16
"
x
1
2
"
6"Ø
EF
1
6"Ø
EF
1
6"Ø
EF
1
6"Ø
EF
2
1
2
3
4
5
6
GARAGE
116
MUDROOM
114
DN
LAUNDRY ROOM
115
BALCONY
104
POWDER ROOM
107
MASTER BATHROOM
108
UP
STAIR:
10" TREAD/7.75"
RISER
TOILET
109
CORRIDOR
110
CLOSET
112CLOSET
111
MASTER BEDROOM
113
CORRIDOR
106
ATRIUM
105
UP
BALCONY
102
PACKAGE ROOM
101
ENTRY CLOSET
103
EF
1
6"Ø
20
"
x
1
4
"
20"x14"20"x14"
ERV
1
TYPE C
26"
X
1
2
"
10"Ø
10"Ø
10"Ø
10"Ø
320 CFM
TYPE B
320 CFM
TYPE B
320 CFM
TYPE B
320 CFM
TYPE B
320 CFM
TYPE B
FC
6
H
6
20
"
X
1
6
"
16"X10"
8"
Ø
8"
Ø
18"X12"
8"
Ø
8"
Ø
12
"
X
1
2
"
200 CFM
TYPE A
CU
1
CU
2
CU
3
CU
4
CU
5
CU
6
16"x14"
ERV
1
8"
Ø
M1-2
GENERAL CONTRACTOR
Janckila Construction Inc.
75 Buckskin Drive
Carbondale, CO 81623
T 970.963.7239
F 970.963.7239
STRUCTURAL ENGINEER
Albright and Associates
402 Park Ave., Unit A
Basalt, CO 81621
T 970.927.4363
CIVIL ENGINEER
Roaring Fork Engineering
592 Highway 133,
Carbondale, CO 81623
T 970.948.7474
MEP ENGINEER
Bighorn Consulting Enginners, Inc.
386 Indian Road
Grand Junction, CO 81501
T 970.241.8709
ACOUSTIC CONSULTANT
Acentech
33 Moulton Street
Cambridge, MA 02138
T 617.499.8000
F 617.499.8074
61
7
W
E
S
T
B
L
E
E
K
E
R
S
T
R
E
E
T
AS
P
E
N
AS
P
E
N
,
C
O
8
1
6
1
1
Drawing Title:
Drawing No:
Phase:
Architect
29 Stanhope Street
3rd Floor
Boston, MA 02116
T 617.426.0995
F 617.426.0998
MONICA PONCE DE LEON
STUDIO, INC.
DATE & ISSUE DESCRIPTION BY CHECK
ISSUE/
REVISION
Project Number:
19-046
RE
S
I
D
E
N
C
E
03/02/2020 PERMIT SET BCE BCE1
GROUND LEVEL FLOOR PLAN
1 MECHANICAL - GROUND LEVEL FLOOR PLAN
SCALE: 1/4" = 1'-0"
MECHANICAL
N
04/13/2020
07/29/2020
TF/JH
350 CFM300 CFM325 CFM
TYPE B
75 CFM
TYPE A
75 CFM
TYPE A
75 CFM
TYPE A
200 CFM
TYPE A
200 CFM
TYPE A
200 CFM
TYPE A
200 CFM
TYPE A
200 CFM
TYPE A
125 CFM
TYPE A
125 CFM
TYPE A
250 CFM
250 CFM
250 CFM
200 CFM
TYPE A
200 CFM
TYPE A
18"X12"
EF
1 6"Ø
EF
1
6"Ø
EF
1
6"Ø
EF
1 6"Ø
1
2
3
4
5
6
BEDROOM 1
208
BEDROOM 2
212
BEDROOM 3
216
BATHROOM 1
209
BATHROOM 3
219
BATHROOM 2
213
DN
UP
CORRIDOR
210
CLOSET
211
CORRIDOR
214
CLOSET
215
CORRIDOR
217
CLOSET
218
CORRIDOR
220
LIVING ROOM
222
ENTRY
205
BAR
206
PDR
204
DINING ROOM
203
BALCONY
202
DECK
224
HOT TUB
223
CORRIDOR
221
CORRIDOR
207
PLANTER
225
KITCHEN
201
TYPE B TYPE B
TYPE B
TYPE B
TYPE B
TYPE C
TYPE B
TYPE B
TYPE B
TYPE B
GENERAL CONTRACTOR
Janckila Construction Inc.
75 Buckskin Drive
Carbondale, CO 81623
T 970.963.7239
F 970.963.7239
STRUCTURAL ENGINEER
Albright and Associates
402 Park Ave., Unit A
Basalt, CO 81621
T 970.927.4363
CIVIL ENGINEER
Roaring Fork Engineering
592 Highway 133,
Carbondale, CO 81623
T 970.948.7474
MEP ENGINEER
Bighorn Consulting Enginners, Inc.
386 Indian Road
Grand Junction, CO 81501
T 970.241.8709
ACOUSTIC CONSULTANT
Acentech
33 Moulton Street
Cambridge, MA 02138
T 617.499.8000
F 617.499.8074
61
7
W
E
S
T
B
L
E
E
K
E
R
S
T
R
E
E
T
AS
P
E
N
AS
P
E
N
,
C
O
8
1
6
1
1
Drawing Title:
Drawing No:
Phase:
Architect
29 Stanhope Street
3rd Floor
Boston, MA 02116
T 617.426.0995
F 617.426.0998
MONICA PONCE DE LEON
STUDIO, INC.
DATE & ISSUE DESCRIPTION BY CHECK
ISSUE/
REVISION
Project Number:
19-046
RE
S
I
D
E
N
C
E
03/02/2020 PERMIT SET BCE BCE1
M1-3
1 MECHANICAL - SECOND LEVEL FLOOR PLAN
SCALE: 1/4" = 1'-0"
MECHAICAL
SECOND LEVEL FLOOR PLAN
N
04/13/2020
07/29/2020
TF/JH
ATTIC
301
DN
1
2
3
4
5
6
GENERAL CONTRACTOR
Janckila Construction Inc.
75 Buckskin Drive
Carbondale, CO 81623
T 970.963.7239
F 970.963.7239
STRUCTURAL ENGINEER
Albright and Associates
402 Park Ave., Unit A
Basalt, CO 81621
T 970.927.4363
CIVIL ENGINEER
Roaring Fork Engineering
592 Highway 133,
Carbondale, CO 81623
T 970.948.7474
MEP ENGINEER
Bighorn Consulting Enginners, Inc.
386 Indian Road
Grand Junction, CO 81501
T 970.241.8709
ACOUSTIC CONSULTANT
Acentech
33 Moulton Street
Cambridge, MA 02138
T 617.499.8000
F 617.499.8074
61
7
W
E
S
T
B
L
E
E
K
E
R
S
T
R
E
E
T
AS
P
E
N
AS
P
E
N
,
C
O
8
1
6
1
1
Drawing Title:
Drawing No:
Phase:
Architect
29 Stanhope Street
3rd Floor
Boston, MA 02116
T 617.426.0995
F 617.426.0998
MONICA PONCE DE LEON
STUDIO, INC.
DATE & ISSUE DESCRIPTION BY CHECK
ISSUE/
REVISION
Project Number:
19-046
RE
S
I
D
E
N
C
E
03/02/2020 PERMIT SET BCE BCE1
M1-4
ATTIC LEVEL FLOOR PLAN
1 MECHANICAL - ATTIC LEVEL FLOOR PLAN
SCALE: 1/4" = 1'-0"
MECHANICAL
N
04/13/2020
07/29/2020
TF/JH
DOWNSPOUT
DOWNSPOUT
DOWNSPOUT
INTERNAL ROOF
DRAIN/ DOWNSPOUT
1
2
3
4
5
6
A B C D E
GENERAL CONTRACTOR
Janckila Construction Inc.
75 Buckskin Drive
Carbondale, CO 81623
T 970.963.7239
F 970.963.7239
STRUCTURAL ENGINEER
Albright and Associates
402 Park Ave., Unit A
Basalt, CO 81621
T 970.927.4363
CIVIL ENGINEER
Roaring Fork Engineering
592 Highway 133,
Carbondale, CO 81623
T 970.948.7474
MEP ENGINEER
Bighorn Consulting Enginners, Inc.
386 Indian Road
Grand Junction, CO 81501
T 970.241.8709
ACOUSTIC CONSULTANT
Acentech
33 Moulton Street
Cambridge, MA 02138
T 617.499.8000
F 617.499.8074
61
7
W
E
S
T
B
L
E
E
K
E
R
S
T
R
E
E
T
AS
P
E
N
AS
P
E
N
,
C
O
8
1
6
1
1
Drawing Title:
Drawing No:
Phase:
Architect
29 Stanhope Street
3rd Floor
Boston, MA 02116
T 617.426.0995
F 617.426.0998
MONICA PONCE DE LEON
STUDIO, INC.
DATE & ISSUE DESCRIPTION BY CHECK
ISSUE/
REVISION
Project Number:
19-046
RE
S
I
D
E
N
C
E
03/02/2020 PERMIT SET BCE BCE1
M1-5
ROOF PLAN
1 MECHANICAL - ROOF PLAN
SCALE: 1/4" = 1'-0"
MECHANICAL
N
04/13/2020
07/29/2020
TF/JH
(3) LOOP
ZONE 1
238 FT/LOOP
1/2 GPM/LOOP
(1) LOOP
ZONE 2
212 FT/LOOP
1/2 GPM/LOOP
(1) LOOP
ZONE 3
163 FT/LOOP
1/2 GPM/LOOP
(2) LOOP
ZONE 4
173 FT/LOOP
1/2 GPM/LOOP
(1) LOOP
ZONE 5
168 FT/LOOP
1/2 GPM/LOOP
(1) LOOP
ZONE 6
246 FT/LOOP
1/2 GPM/LOOP
MEDIA ROOM
001
PDR
002
SPORTS COURT
003
WORKOUT ROOM
009
SAUNA
008
STORAGE
007
GUEST BEDROOM
015
GUEST
BATHROOM
016
STORAGE
011
LAUNDRY ROOM
005
MECHANICAL ROOM
012
ATRIUM
004
CORRIDOR
006
CORRIDOR
010
STAIR
014
CORRIDOR
013
UP
UP
UTILITY ROOM
017
1
2
3
4
5
6
GENERAL CONTRACTOR
Janckila Construction Inc.
75 Buckskin Drive
Carbondale, CO 81623
T 970.963.7239
F 970.963.7239
STRUCTURAL ENGINEER
Albright and Associates
402 Park Ave., Unit A
Basalt, CO 81621
T 970.927.4363
CIVIL ENGINEER
Roaring Fork Engineering
592 Highway 133,
Carbondale, CO 81623
T 970.948.7474
MEP ENGINEER
Bighorn Consulting Enginners, Inc.
386 Indian Road
Grand Junction, CO 81501
T 970.241.8709
ACOUSTIC CONSULTANT
Acentech
33 Moulton Street
Cambridge, MA 02138
T 617.499.8000
F 617.499.8074
61
7
W
E
S
T
B
L
E
E
K
E
R
S
T
R
E
E
T
AS
P
E
N
AS
P
E
N
,
C
O
8
1
6
1
1
Drawing Title:
Drawing No:
Phase:
Architect
29 Stanhope Street
3rd Floor
Boston, MA 02116
T 617.426.0995
F 617.426.0998
MONICA PONCE DE LEON
STUDIO, INC.
DATE & ISSUE DESCRIPTION BY CHECK
ISSUE/
REVISION
Project Number:
19-046
RE
S
I
D
E
N
C
E
03/02/2020 PERMIT SET BCE BCE1
M2-1
BASEMENT LEVEL FLOOR PLAN
1 MECHANICAL - BASEMENT LEVEL FLOOR PLAN
SCALE: 1/4" = 1'-0"
MECHANICAL
N
04/13/2020
07/29/2020
TF/JH
(1) LOOP
ZONE 7
74 FT/LOOP
1/2 GPM/LOOP
(1) LOOP
ZONE 8
226 FT/LOOP
1/2 GPM/LOOP
(1) LOOP
ZONE 9
158 FT/LOOP
1/2 GPM/LOOP
(2) LOOP
ZONE 10
228 FT/LOOP
1/2 GPM/LOOP
(1) LOOP
ZONE 11
202 FT/LOOP
1/2 GPM/LOOP
(1) LOOP
ZONE 12
152 FT/LOOP
1/2 GPM/LOOP
(1) LOOP
ZONE 13
61 FT/LOOP
1/2 GPM/LOOP
(3) LOOP
ZONE 14
227 FT/LOOP
1/2 GPM/LOOP
1
2
3
4
5
6
A B C D E
GARAGE
116
MUDROOM
114
DN
LAUNDRY ROOM
115
BALCONY
104
POWDER ROOM
107
MASTER BATHROOM
108
UP
STAIR:
10" TREAD/7.75"
RISER
TOILET
109
CORRIDOR
110
CLOSET
112CLOSET
111
MASTER BEDROOM
113
CORRIDOR
106
ATRIUM
105
UP
BALCONY
102
PACKAGE ROOM
101
ENTRY CLOSET
103
GENERAL CONTRACTOR
Janckila Construction Inc.
75 Buckskin Drive
Carbondale, CO 81623
T 970.963.7239
F 970.963.7239
STRUCTURAL ENGINEER
Albright and Associates
402 Park Ave., Unit A
Basalt, CO 81621
T 970.927.4363
CIVIL ENGINEER
Roaring Fork Engineering
592 Highway 133,
Carbondale, CO 81623
T 970.948.7474
MEP ENGINEER
Bighorn Consulting Enginners, Inc.
386 Indian Road
Grand Junction, CO 81501
T 970.241.8709
ACOUSTIC CONSULTANT
Acentech
33 Moulton Street
Cambridge, MA 02138
T 617.499.8000
F 617.499.8074
61
7
W
E
S
T
B
L
E
E
K
E
R
S
T
R
E
E
T
AS
P
E
N
AS
P
E
N
,
C
O
8
1
6
1
1
Drawing Title:
Drawing No:
Phase:
Architect
29 Stanhope Street
3rd Floor
Boston, MA 02116
T 617.426.0995
F 617.426.0998
MONICA PONCE DE LEON
STUDIO, INC.
DATE & ISSUE DESCRIPTION BY CHECK
ISSUE/
REVISION
Project Number:
19-046
RE
S
I
D
E
N
C
E
03/02/2020 PERMIT SET BCE BCE1
M2-2
GROUND LEVEL FLOOR PLAN
1 MECHANICAL - GROUND LEVEL FLOOR PLAN
SCALE: 1/4" = 1'-0"
MECHANICAL
N
04/13/2020
07/29/2020
TF/JH
(1) LOOP
ZONE 15
271 FT/LOOP
1/2 GPM/LOOP
(2) LOOP
ZONE 16
193 FT/LOOP
1/2 GPM/LOOP (3) LOOP
ZONE 17
202 FT/LOOP
1/2 GPM/LOOP
(5) LOOP
ZONE 19
283 FT/LOOP
1/2 GPM/LOOP
1
2
3
4
5
6
A B C D E
BEDROOM 1
208
BEDROOM 2
212
BEDROOM 3
216
BATHROOM 1
209
BATHROOM 3
219
BATHROOM 2
213
DN
UP
CORRIDOR
210
CLOSET
211
CORRIDOR
214
CLOSET
215
CORRIDOR
217
CLOSET
218
CORRIDOR
220
LIVING ROOM
222
ENTRY
205
BAR
206
PDR
204
DINING ROOM
203
BALCONY
202
DECK
224
HOT TUB
223
CORRIDOR
221
CORRIDOR
207
PLANTER
225
KITCHEN
201
GENERAL CONTRACTOR
Janckila Construction Inc.
75 Buckskin Drive
Carbondale, CO 81623
T 970.963.7239
F 970.963.7239
STRUCTURAL ENGINEER
Albright and Associates
402 Park Ave., Unit A
Basalt, CO 81621
T 970.927.4363
CIVIL ENGINEER
Roaring Fork Engineering
592 Highway 133,
Carbondale, CO 81623
T 970.948.7474
MEP ENGINEER
Bighorn Consulting Enginners, Inc.
386 Indian Road
Grand Junction, CO 81501
T 970.241.8709
ACOUSTIC CONSULTANT
Acentech
33 Moulton Street
Cambridge, MA 02138
T 617.499.8000
F 617.499.8074
61
7
W
E
S
T
B
L
E
E
K
E
R
S
T
R
E
E
T
AS
P
E
N
AS
P
E
N
,
C
O
8
1
6
1
1
Drawing Title:
Drawing No:
Phase:
Architect
29 Stanhope Street
3rd Floor
Boston, MA 02116
T 617.426.0995
F 617.426.0998
MONICA PONCE DE LEON
STUDIO, INC.
DATE & ISSUE DESCRIPTION BY CHECK
ISSUE/
REVISION
Project Number:
19-046
RE
S
I
D
E
N
C
E
03/02/2020 PERMIT SET BCE BCE1
M2-3
1 MECHANICAL - SECOND LEVEL FLOOR PLAN
SCALE: 1/4" = 1'-0"
MECHAICAL
SECOND LEVEL FLOOR PLAN
N
04/13/2020
07/29/2020
TF/JH
(1) LOOP
ZONE 18
126 FT/LOOP
1/2 GPM/LOOP
ATTIC
301
DN
1
2
3
4
5
6
GENERAL CONTRACTOR
Janckila Construction Inc.
75 Buckskin Drive
Carbondale, CO 81623
T 970.963.7239
F 970.963.7239
STRUCTURAL ENGINEER
Albright and Associates
402 Park Ave., Unit A
Basalt, CO 81621
T 970.927.4363
CIVIL ENGINEER
Roaring Fork Engineering
592 Highway 133,
Carbondale, CO 81623
T 970.948.7474
MEP ENGINEER
Bighorn Consulting Enginners, Inc.
386 Indian Road
Grand Junction, CO 81501
T 970.241.8709
ACOUSTIC CONSULTANT
Acentech
33 Moulton Street
Cambridge, MA 02138
T 617.499.8000
F 617.499.8074
61
7
W
E
S
T
B
L
E
E
K
E
R
S
T
R
E
E
T
AS
P
E
N
AS
P
E
N
,
C
O
8
1
6
1
1
Drawing Title:
Drawing No:
Phase:
Architect
29 Stanhope Street
3rd Floor
Boston, MA 02116
T 617.426.0995
F 617.426.0998
MONICA PONCE DE LEON
STUDIO, INC.
DATE & ISSUE DESCRIPTION BY CHECK
ISSUE/
REVISION
Project Number:
19-046
RE
S
I
D
E
N
C
E
03/02/2020 PERMIT SET BCE BCE1
M2-4
ATTIC LEVEL FLOOR PLAN
1 MECHANICAL - ATTIC LEVEL FLOOR PLAN
SCALE: 1/4" = 1'-0"
MECHANICAL
N
04/13/2020
07/29/2020
TF/JH
GENERAL CONTRACTOR
Janckila Construction Inc.
75 Buckskin Drive
Carbondale, CO 81623
T 970.963.7239
F 970.963.7239
STRUCTURAL ENGINEER
Albright and Associates
402 Park Ave., Unit A
Basalt, CO 81621
T 970.927.4363
CIVIL ENGINEER
Roaring Fork Engineering
592 Highway 133,
Carbondale, CO 81623
T 970.948.7474
MEP ENGINEER
Bighorn Consulting Enginners, Inc.
386 Indian Road
Grand Junction, CO 81501
T 970.241.8709
ACOUSTIC CONSULTANT
Acentech
33 Moulton Street
Cambridge, MA 02138
T 617.499.8000
F 617.499.8074
61
7
W
E
S
T
B
L
E
E
K
E
R
S
T
R
E
E
T
AS
P
E
N
AS
P
E
N
,
C
O
8
1
6
1
1
Drawing Title:
Drawing No:
Phase:
Architect
29 Stanhope Street
3rd Floor
Boston, MA 02116
T 617.426.0995
F 617.426.0998
MONICA PONCE DE LEON
STUDIO, INC.
DATE & ISSUE DESCRIPTION BY CHECK
ISSUE/
REVISION
Project Number:
19-046
RE
S
I
D
E
N
C
E
03/02/2020 PERMIT SET BCE BCE1
07/01/2020 CD REVIEW SET BCE BCE2
M3-1
DETAILS
MECHANICAL
MECHANICAL PROVISIONS
1. SCOPE OF WORK
A. THE CONTRACTOR IS RESPONSIBLE FOR ALL WORK, MATERIALS,
AND LABOR TO SATISFY A COMPLETE WORKING SYSTEM WHETHER
SPECIFIED OR IMPLIED.
B. ALL WORK IS TO BE PERFORMED IN STRICT COMPLIANCE WITH
ALL LOCAL CODES AND ALL OTHER REGULATION GOVERNING WORK
OF THIS NATURE.
C. THE CONTRACTOR SHALL, BEFORE SUBMITTING ANY PROPOSAL,
EXAMINE THE PROPOSED SITE AND SHALL DETERMINE FOR HIMSELF
THE CONDITIONS THAT MAY EFFECT THE WORK. NO ALLOWANCE SHALL
BE MADE IF THE CONTRACTOR FAILS TO MAKE SUCH EXAMINATIONS.
D. ALL EQUIPMENT AND MATERIALS SHALL BE AS SPECIFIED OR
"APPROVED EQUAL" BY THE ENGINEER OR ARCHITECT.
2. PERMITS
A. THE CONTRACTOR SHALL SECURE ALL PERMITS OR APPLICATIONS AND
PAY ANY AND ALL FEES.
3. SHOP DRAWINGS
A. SUBMIT MATERIAL LIST AND SHOP DRAWINGS FOR MAJOR EQUIPMENT
TO THE ACHITECT/ENGINEER FOR APPROVAL. THE CONTRACTOR SHALL
SUBMIT ELECTRONIC SHOP DRAWINGS AND THEY SHALL BE CLEARLY
LABELED.
4. FLEXIBLE DUCT WORK - SUPPORT/HANG DUCTS ABOVE CEILING INSULATION, TYP.
A. FLEXIBLE TYPE DUCT SHALL BE OF TWO ELEMENT SPIRAL CONSTRUCTION
COMPOSED OF A CORROSION RESISTANT METAL SUPPORTING SPIRAL AND
COATED FABRIC WITH A MINERIAL BASE. FLEXIBLE DUCT CONNECTORS
SHALL BE LISTED BY U.L., CLASS 1 DUCTS, AND SHALL HAVE A
FLAME SPREAD RATING NOT EXCEEDING 25 AND A SMOKE DEVELOPED
RATING NOT EXCEEDING 50.
B. USE OF FLEXIBLE DUCTWORK SHALL BE LIMITED TO NO MORE THAN
6 LINEAR FEET PER RUN.
C. CONTRACTOR SHALL BE CAREFUL SO AS NOT TO KINK OR COLLAPSE
FLEXIBLE DUCT.
5. REFRIGERENT
A. PIPING CONTRACTOR SHALL PROVIDE AND INSTALL REFRIGERANT
PIPING IN ACCORDANCE WITH THE MANUFACTURER'S REC0MMENDATIONS
AND IN SUCH A WAY AS TO BE INCONSPICIOUS AND FREE FROM ANY
POSSIBLE CONDENSATION.
B. INSULATE REFRIGERANT LINES WITH ARMOUR-FLEX TYPE INSULATION,
SHALL BE TYPE "K" COPPER TUBING, WITH WROUGHT COPPER SOLDER
TYPE FITTINGS SUITABLE FOR CONNECTION WITH SILVER SOLDER.
6. DUCTWORK
A. THE DUCTWORK SHALL BE CONSTRUCTED IN ACCORDANCE
WITH THE "SMACNA" APPLICABLE MANUALS.
B. ALL DUCTWORK SHALL BE THE LOW VELOCITY TYPE, UNLESS SPECIFIED
OTHERWISE.
C. CONTRACTOR SHALL PROVIDE AND INSTALL APPROVED FIRE
DAMPERS AND ACCESS PANELS IN ANY AND ALL DUCTWORK WHICH
PENETRATES A HORIZONTAL OR VERTICAL FIRE PARTITION, OR AS
OTHERWISE SHOWN ON DRAWINGS.
D. ALL BRANCH DUCTS TO HAVE VOLUME DAMPERS, SMOOTH TURN RADIUS
DUCTWORK OR TURNING VANES SHALL BE USED THROUGHOUT WHERE FLOW
EXCEEDS 150 CFM.
E. ALL DUCT JOINTS TO BE SEALED IN ACCORDANCE WITH "SMACNA"
STANDARDS AND ACCEPTED GOOD PRACTICE.
F. ALL DUCT DIMENSIONS SHOWN ARE NET OPEN INSIDE VALUES. DIMENSIONS MAY
BE CHANGED SO LONG AS THE NET FREE FACE AREA IS MAINTAINED
G. ALL CONCEALED DUCTWORK SHALL BE INSULATED WITH 1-1/2"
FIBERGLASS INSULATING BLANKET WITH ALUMINUM FOIL FACING OR 1-1/2" LINER.
ALL SEAMS SEALED.
H. ALL SUPPLY AND RETURN DUCTWORK 15 FEET DOWNSTREAM OF THE HVAC
UNIT SHALL BE INTERNALLY LINED WITH A 1/2" ACOUSTICAL DUCT LINER
UNLESS OTHERWISE NOTED ON THE DRAWINGS.
7. DRAINAGE PIPING
A. (CONDENSATE) SHALL BE SCHEDULE 40 PVC PIPE WITH SOLVENT JOINTS.
PITCH HORIZONTAL LINES 1" IN 10'-0". CONDENSATE DRAINS SHALL BE
ROUTED TO FLOOR DRAIN, ROOF DRAIN OR INDIRECT WASTE DRAIN.
8. HVAC CONTROLS
A. CONTRACTOR TO SUPPLY AND INSTALL ALL CONTROL WIRING AND
THERMOSTATS AS REQUIRED.
9. ELECTRICAL
A. CONTRACTOR TO COORDINATE WITH ELECTRICAL CONTRACTOR FOR
LOCATION OF WIRING FOR EACH HVAC UNIT.
10. PIPE SUPPORTS
A. ALL PIPE SHALL BE SUPPORTED FROM THE BUILDING STRUCTURE IN A
NEAT AND WORKMANLIKE MANNER. THE USE OF WIRE OR METAL STRAP TO
SUPPORT PIPES WILL NOT BE PERMITTED. SPACING OF PIPE SUPPORTS
SHALL NOT EXCEED 8 FEET FOR ALL PIPING. PLASTIC PIPING TO BE
SUPPORTED EVERY 4 FEET.
11. GAS PIPING
A. PIPING SHALL BE SCHEDULE 40 BLACK STEEL PIPE WITH MALLEABLE IRON
FITTINGS.
WHERE GAS PIPE CONNECTS TO EQUIPMENT, IT SHALL BE PROVIDED WITH A
DRIP LEG THE FULL SIZE OF THE RUNOUT, A 100% SHUT-OFF VALVE AND A
UNION. GAS PIPING CONTAINING PRESSURE GREATER THAN 9" W.G. SHALL
BE SCHEDULE 40 BLACK STEEL PIPE WITH WELDED JOINTS.
12. MISCELLANEOUS
A. ALL EXTERIOR OPENINGS TO BE PROPERLY CAULKED AND SEALED WITH A
SEALANT OF HIGH QUALITY AND LONG LIFE, TO PREVENT INFILTRATION
OF OUTSIDE AIR INTO CONDITIONED SPACE.
COORDINATE INSTALLATION OF ALL ROOF FLASHING AT ROOF PENETRATION.
B. DO NOT SCALE THIS DRAWING FOR EXACT DIMENSIONS.
C. VERIFY ALL FIGURES, CONDITIONS, AND DIMENSIONS AT THE JOB SITE.
D. THE MECHANICAL PLANS ARE INTENDED TO BE DIAGRAMMATIC AND ARE BASED
ON ONE MANUFACTURE'S EQUIPMENT. THEY ARE NOT INTENDED TO SHOW EVERY
ITEM IN ITS EXACT LOCATION, THE EXACT DIMENSIONS, OR ALL THE
DETAILS OF THE EQUIPMENT.
E. THE CONTRACTOR SHALL VERIFY THE ACTUAL DIMENSIONS OF THE EQUIPMENT
PROPOSED TO ENSURE THAT THE EQUIPMENT WILL FIT IN THE AVAILABLE
SPACE.
13. TESTING AND BALANCING
A. THE HVAC SYSTEM SHALL BE TESTED AND AND BALANCED BY AN INDEPENDENT
AGENCY, UNDER THE SUPERVISION OF A LICENSED PROFESSIONAL ENGINEER.
A SEALED TYPE WRITTEN REPORT SHALL BE SUBMITTED TO THE
ARCHITECT/ENGINEER FOR REVIEW AND APPROVAL.
14. GUARANTEE
A. MATERIALS, EQUIPMENT AND INSTALLATION SHALL BE GUARANTEED FOR A
PERIOD OF ONE(1) YEAR FROM DATE OF ACCEPTANCE. DEFECTS WHICH
APPEAR DURING THAT PERIOD SHALL BE CORRECTED AT THIS CONTRACTOR'S
EXPENSE.
B. FOR THE SAME PERIOD, THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE
FOR ANY DAMAGE TO PREMISES CAUSED BY DEFECTS IN WORKMANSHIP OR IN THE
WORK OR EQUIPMENT FURNISHED AND/OR INSTALLED BY HIM.
EXHAUST FAN SCHEDULE
EQUIPMENT NO.SERVICE LOCATION CFM EXTERNAL STATIC PRESS (IN.
W.G.)
MOTOR
MANUFACTURER & MODEL OPTIONS/ACCESSORIES
WATTS HP RPM VOLT/PH/HZ
EF-1 RESTROOM CEILING MOUNTED 75 0.25 10.20 -###120/1/60 PANASONIC FV-05-11VK1 NOTE-1
EF-2 GARAGE CEILING MOUNTED 200 0.2 59.00 -###120/1/60 COOK GC-186 NOTE-1
NOTES:
1. PROVIDE WITH MOTOR STARTER, POWER DISCONNECT, AND BELT DRIVEN VFD MOTOR.
FAN COIL SCHEDULE
EQUIPMENT NO.SERVICE
SUPPLY
AIR
(CFM)
OUTSIDE
AIR
(CFM)
SUPPLY
AIR
E.S.P.
(IN. W.G.)
COOLING HOT WATER HEATING COIL
FILTERS SUPPLY FAN
(HP)
ELECTRICAL
UNIT
WEIGHT
(LBS.)
MANUFACTURER & MODEL OPTIONS /ACCESSORIESNOM.
(TONS)
OUTPUT
(MBH)
FLOW
(GPM)
EWT
(°F)
(MBH)
V./PH./HZ.MCA MOCP
FC-1 GYM 1,600 300 1.5 4 60 4.0 140 2" TA 0.5 120/1/60 10.2 15 165 LENNOX - CBWMV036 NOTE-1
FC-2 BASEMENT 1,400 1.5 3 48 3.2 140 2" TA 0.5 120/1/60 10.2 15 165 LENNOX - CBWMV060 NOTE-1
FC-3 MASTER 1,900 1.5 4 53 3.5 140 2" TA 0.5 120/1/60 10.2 15 165 LENNOX - CBWMV060 NOTE-1
FC-4 GROUND LEVEL 1,350 1.5 3 46 3.1 140 2" TA 0.5 120/1/60 10.2 15 165 LENNOX - CBWMV060 NOTE-1
FC-5 ENTRY 1,350 1.5 3 15 1.0 140 2" TA 0.5 120/1/60 10.2 15 165 LENNOX - CBWMV036 NOTE-1
FC-6 FLOOR 2 2,000 1.5 5 150 10.0 140 2" TA 0.5 120/1/60 10.2 15 165 LENNOX - CBWMV036 NOTE-1
NOTES:
1. PROVIDE WITH FILTERS AND RACK, DX COOLING COIL, HOT WATER HEATING COIL, POWER DISCONNECT, FLEX DUCT CONNECTION, VIBRATION ISOLATION HANGING KIT AND REMOTE MOUNTED THERMOSTAT.
BOILER SCHEDULE
EQUIPMENT NO.SERVICE
INPUT
CAPACITY
(BTU/HR.)
OUTPUT
CAPACITY
(BTU/HR.)
BOILER
VOLUME
(GALLONS)
FLUE/COMB. AIR
SIZE (INCHES)
ELECTRICAL
MANUFACTURER & MODEL OPTIONS/ACCESSORIES
AMPS V./PH./HZ.
BL-1 DOMESTIC/ RADIANT 500 394 5 4 120/1/60 LOCHINVAR KBN501 NOTE-1
BL-2 DOMESTIC/ RADIANT 500 394 5 4 120/1/60 LOCHINVAR KBN501 NOTE-1
NOTES:
1. PROVIDE WITH ASME RELIEF VALVE, CSD-1 CONTROLS, CONCENTRIC VENT KIT, LOW-WATER CUTOFF WITH MANUAL RESET & TEST, FLOW SWITCH, ADJUSTABLE HIGH LIMIIT WITH MANUAL
RESET, MODULATING TEMPERATURE CONTROL, CONDENSATE NEUTRALIZING KIT, HIGH ALTITUDE KIT SIZED PER LOCATION ELEVATION, AND BLOWER MOTOR.
HUMIDIFIER SCHEDULE
EQUIPMENT NO.SERVICE LOCATION OUTPUT (LBS./HR.)AMPS V/PH/HZ MANUFACTURER & MODEL OPTIONS/ACCESSORIES
H-1 (5)FC-1,2,3,4,6 DUCT 5 20 120/1/60 NORTEC RH2+NOTE-1
NOTES:
1. PROVIDE WITH EACH HUMIDIFIER DUCT MOUNTED HUMIDISTAT, OUTDOOR AIR RESET HIGH LIMIT SWITCH DRAIN PAN STEAM TUBE WITH SAM
MANIFOLD, CONDESATE TUBE, DRAIN, POWER DISCONNECT, ETC.
PUMP SCHEDULE
EQUIPMENT NO.SERVICE LOCATION GPM HEAD (FT.)MANUFACTURER & MODEL OPTIONS/ACCESSORIES
RPM V./PH./HZ.HP FLA
RCP-1 DOMESTIC WATER RECIRC MECH. RM 5 25 VARIABLE 230/1/60 0.33 2 TACO 0012 NOTE-5
CP-2 BOILER MECH. RM 58 50 VARIABLE 115/1/60 1.50 2 TACO VR25 NOTE-1
CP-3 SNOWMELT MECH. RM 80 15 VARIABLE 115/1/60 2.2 6 TACO VR30 NOTE-2
CP-4 RADIANT CIRCULATION MECH. RM.17 30 VARIABLE 115/1/60 0.68 1 TACO VR15 NOTE-3
CP-5 FAN COIL MECH. RM 25 30 VARIABLE 115/1/60 1.50 6 TACO VR25 NOTE-4
CP-6 BOILER LOOP MECH. RM.110 30 VARIABLE 115/1/60 2.20 8 TACO VR30 NOTE-4
CP-7 DOM. WATER .MECH. RM.14 30 VARIABLE 115/1/60 0.68 2 TACO VR15 NOTE-5
CP-8 RADIANT INJECTION PUMP MECH. RM.2.5 30 VARIABLE 115/1/60 0.68 2 TACO VR15 NOTE-6
NOTES:
1. PROVIDE WITH CAST IRON CASING, POWER DISCONNECT, MOTOR STARTER, COMPOSITE (PES) IMPELLER, FLANGED CONNNECTIONS AND 3-SPEED MOTOR. MOTOR HORSEPOWER SHALL BE GREATER
THAN NON-OVERLOADING BRAKE HORSEPOWER.
2. PROVIDE WITH CAST IRON CASING, POWER DISCONNECT, MOTOR STARTER, STAINLESS STEEL IMPELLER, FLANGED CONNNECTIONS AND 3-SPEED MOTOR. MOTOR HORSEPOWER SHALL BE GREATER
THAN NON-OVERLOADING BRAKE HORSEPOWER.
3. PROVIDE WITH ECM MOTOR, MOTOR STARTER, FIBERGLASS REINFORCED PPS IMPELLER, STAINLESS STEEL SHAFT, METAL IMPREGNATED CARBON, CAST IRON VOLUTE, POWER DISCONNECT,
REQUIRED MINIMUM INLET PRESSURE AT TEMPERATURE.
4. PROVIDE WITH CAST IRON CASING, ECM MOTOR, POWER DISCONNECT, MOTOR STARTER, STAINLESS STEEL IMPELLER, STAINLESS STEEL SHAFT, IMPREGNATED CARBON METAL BEARING, FLANGED
CONNECTIONS. MOTOR HORSEPOWER SHALL BE GREATER THAN NON-OVERLOADING BRAKE HORSEPOWER.
5. PROVIDE WITH STAINLESS STEEL CASING, POWER DISCONNECT, MOTOR STARTER, NON METALLIC IMPELLER, CERAMIC SHAFT, CARBON BEARING, FLANGED CONNECTIONS, INTEGRAL FLOW CHECK
VALVE. MOTOR HORSEPOWER SHALL BE GREATER THAN NON-OVERLOADING BRAKE HORSEPOWER.
6. PROVIDE WITH POWER DISCONNECT, NON METALLIC IMPELLER, FLANGED CONNECTIONS, INSTALL PER MANUFACTURER'S INSTRUCTIONS/RECOMMENDATIONS.
INDIRECT WATER HEATER SCHEDULE
EQUIPMENT NO CAPACITY RECOVERY @100 DEG F. RISE BTU PER HR.BOILER CONNECTION WATER CONNECTION MANUFACTURER & MODEL OPTIONS/ACCESSORIES
WH-1 119 308 199,999 1"1-1/2"LOCHINVAR SIT 119 NOTE-1
NOTES:
1. PROVIDE WITH ISOLATION VALVES.
GRILLE-REGISTER-DIFFUSER SCHEDULE
EQUIPMENT NO.SIZE MODEL MANUFACTURER FINISH OPTIONS/ACCESSORIES
A 3"X36"1500 KRUEGER TBD NOTE-1
B 3"X60"1500 KRUEGER TBD NOTE-1
C 24"X24"S80P KRUEGER TBD NOTE-2
NOTES:
1. INSTALL WITH BALANCING DAMPER, COORDINATE MODEL WITH MOUNTING TYPE.
2. COORDINATE MOUNTING TYPE WITH SURFACE.
ENERGY RECOVER VENTILATOR SCHEDULE
EQUIPMENT NO.SERVICE LOCATION SUPPLY CFM
TEMPERATURE
E.S.P (IN W.G.)
SUPPLY FAN
E.S.P. (IN W.G.)EXHAUST CFM
EXHAUST FAN
MANUFACTURER & MODEL OPTIONS/ACCESSORIES
E.A.T L.A.T HP TYPE:V./PH./HZ.HP TYPE:V./PH./HZ.
ERV-1(3)FAN COILS RETURN
DUCTS 120 -5 60 0.25 -VFD 120/1/60 0.25 120 -VFD 120/1/60 RENEWAIRE BR130 NOTE-1
NOTES:
1. PROVIDE WITH RETURN AIR THERMOSTAT, INTERNALLY MOUNTED CONTROL CENTER SENSORS, MOTOR STARTER, CONTROL TRANSFORMER, HANGERS AND RUBBER IN SHEAR VIBRATION ISOLATORS, DOUBLE WALL CONSTRUCTION, FILTERS ON THE OUTSIDE AIR
INTAKE, DEFROST PREHEATER, DUCT FLANGES, AND CONVENIENCE OUTLETS. UNIT SHALL OPERATE 25% OF THE TIME AND EXCEEDS LOCAL OUTSIDE AIR REQUIREMENTS. DUCTWORK ROUTING CORDINATION TO EXTERIOR AT DIGRESSION OF CONTRACTOR
AIR COOLED CONDENSING UNIT SCHEDULE
EQUIPMENT
NO.SERVICE
NOMINAL
COOLING
CAPACITY
(TON)
REFRIG. PIPING ELECTRIC
MANUFACTURER & MODEL OPTIONS/ACESSORIES
LIQUID VAPOR V/PH/HZ MOCP (A)MCA (A)
CU-1 FC-1 4 3/8"7/8"230/1/60 29 50 LENNOX - XC20 NOTE-1
CU-2 FC-2 3 3/8"7/8"230/1/60 29 50 LENNOX - XC20 NOTE-1
CU-3 FC-3 4 3/8"7/8"230/1/60 29 50 LENNOX - XC20 NOTE-1
CU-4 FC-4 3 3/8"7/8"230/1/60 29 50 LENNOX - XC20 NOTE-1
CU-5 FC-5 3 3/8"3/4"230/1/60 29 50 LENNOX - XC20 NOTE-1
CU-6 FC-6 5 3/8"1-1/8"230/1/60 29 50 LENNOX - XC20 NOTE-1
NOTES:
1. PROVIDE LINE SET AS RECOMMENDED BY MANUFACTURER, POWER DISCONNECT, HOUSEKEEPING PAD AND ISOLATION VALVES.
07/29/2020
TF/JH
GENERAL CONTRACTOR
Janckila Construction Inc.
75 Buckskin Drive
Carbondale, CO 81623
T 970.963.7239
F 970.963.7239
STRUCTURAL ENGINEER
Albright and Associates
402 Park Ave., Unit A
Basalt, CO 81621
T 970.927.4363
CIVIL ENGINEER
Roaring Fork Engineering
592 Highway 133,
Carbondale, CO 81623
T 970.948.7474
MEP ENGINEER
Bighorn Consulting Enginners, Inc.
386 Indian Road
Grand Junction, CO 81501
T 970.241.8709
ACOUSTIC CONSULTANT
Acentech
33 Moulton Street
Cambridge, MA 02138
T 617.499.8000
F 617.499.8074
61
7
W
E
S
T
B
L
E
E
K
E
R
S
T
R
E
E
T
AS
P
E
N
AS
P
E
N
,
C
O
8
1
6
1
1
Drawing Title:
Drawing No:
Phase:
Architect
29 Stanhope Street
3rd Floor
Boston, MA 02116
T 617.426.0995
F 617.426.0998
MONICA PONCE DE LEON
STUDIO, INC.
DATE & ISSUE DESCRIPTION BY CHECK
ISSUE/
REVISION
Project Number:
19-046
RE
S
I
D
E
N
C
E
03/02/2020 PERMIT SET BCE BCE1
M3-2
DETAILS
MECHANICAL
SUBFLOOR
WIRSBO 1 1/4" STAPLE
WIRSBO TUBING
POURED FLOOR UNDERLAYMENT
ON A SUSPENDED WOOD FLOOR
POURED UNDERLAYMENT
SUITABLE INSULATION
N.T.S.
FLOOR JOIST
OVER A SAND BED
N.T.S.
SLAB ON OR BELOW GRADE
SAND/SOIL
WIRSBO TUBINGWIRE TIE
BASE MATERIAL
OR EQUAL
INSULATION
CONCRETE SLAB
WIRE MESH, REBAR
OR STAPLE TO RIGID FOAM
SLAB SHIELD OR
WIRSBO
TUBING
SLAB SHIELD
EQUAL INSULATION
GENERAL TUBING NOTES:
SNOWMELT
TUBING IS 5/8" HEATPEX
SPACING IS 10" OC
TEMPERATURE DROP=30°F
SUPPLY=140°F
DENSITY=140 BTUH/FT2
SURFACE TEMPERATURE=37°F
SOLUTION IS 50% PG.
PROVIDE A MINIMUM R-10 INSULATION UNDER SNOWMELT SLAB.
RADIANT FLOOR
TUBING IS 1/2" HEATPEX
SPACING IS 10" OC
SUPPLY=105°F
TEMPERATURE DROP=13°
SOLUTION IS WATER.
INSTALL TUBING UNDER FIREPLACES, TUBS AND SHOWERS AS SHOWN ON THE
FLOOR PLANS. SEE DETAILS FOR RECOMMENDED TUBING PRACTICES.
PROVIDE A MINIMUM R-5 INSULATION UNDER RADIANT FLOOR SLAB.
BUILDING HEATING BOILER PIPING DETAIL
SCALE: NTS NOTE: FINAL FILL OF SYSTEM SHALL BE WITH SOLUTION OF
30% PROPYLENE GLYCOL.
TYPICAL
CONDENSATE DRAIN
~
THERMOMETER
1 1/2"
HWS
AMTROL EXPANSION TANK
~
DOMESTIC COLD WATER
1 1/2"
T115°
HWR
TACO AIR VENT
PRESSURE
1/2"
HWS
EXPANSION TANK
TO DRAIN
4"
1-1/2"
AXIOM #MF300
GLYCOL FEEDER
STRAINER
~
~
TO FAN COILS
25
GPM
DRAIN
3/4"
ANTI-SCALDING VALVE
SUPPLY SENSOR
3/4"
RADIANT MIXING BLOCK INJECTOR PUMP
WITH OUTDOOR SENSOR, BOILER SENSOR,
RADIANT SENSOR. INJECTION FLOW= 2.5 GPM.
SYSTEM CIRCULATION FLOW=16.5 GPM, 108 MBH.
S
S
S
OUTDOOR SENSOR
105°
92°
RADIANT MAINFOLD
RADIANT LOOP, TYPICAL
RADIANT MAINFOLD
RADIANT LOOP, TYPICAL
2"
2"
GPM14
GPM
4"
GAUGE
4"12" MAX.
S
RADIANT MAINFOLD
RADIANT LOOP, TYPICAL
1-1/2"
2"
TACO - CBX300-125
1-1/2"
2"
G G
HWS
MIXING
BLOCK
RADIANT
(INSTALL PER MANUFACTURERS RECOMMENDATION)
3"
DOMESTIC HOT WATER
HWS
G
HWR
G
G
G
PIPE RELIEF DRAIN FULL
SIZE TO FLOOR DRAIN
G
2"
G
HWR
4"
4"TACO 3" AIR SEPARATOR
TACO AIR VENT
3"
3"
4"
3/4"
TO NATURAL GAS
SOURCE
2"
T
SNOWMELT MANIFOLD
SNOWMELT LOOP, TYPICAL
TACO HEAT EXCHANGER 1000 MBH.
HOT SIDE FLOW= 80 GPM, 30% GLYCOL
COLD SIDE FLOW= 86 GPM, 50% GLYCOL
S
120°
90°
MODEL TB120Tx80 OR EQUAL
SNOWMELT MANIFOLD
TACO AIR VENT
1/2"
EXPANSION TANK
TO DRAIN
SNOWMELT LOOP, TYPICAL
SNOWMELT MANIFOLD
SNOWMELT LOOP, TYPICAL
TACO - CBX30-125
TACO 2" AIR SEPARATOR
SNOWMELT
SENSOR
3"
2"
TACO AIR VENT
3"
SEQUENCE OF OPERATION:
ON A CALL FOR HEATING FROM ANY ZONE THERMOSTAT THE BOILER CONTROL SYSTEM SHALL BE ENABLED TO FIRE AND
SEQUENCE THE BOILERS. AT THE SAME TIME, THE PUMP CP-4 AND CP-8 WILL RECEIVE A DEMAND SIGNAL WHICH WILL ALLOW IT
TO START OPERATION AND MAINTAIN RADIANT FLOOR SET POINT TEMPERATURE (ADJ). CP-5 SHALL RECEIVE A DEMAND SIGNAL
WHICH WILL ALLOW IT TO START OPERATION AND MAINTAIN FAN COIL TEMPERATURE. CP-3 AND CP-6 SHALL RECEIVE A DEMAND
SIGNAL WHICH WILL ALLOW IT TO START OPERATION AND MAINTAIN SNOWMELT TEMPERATURE.
THE BOILER CONTROL SYSTEM SHALL CONTROL THE FIRING AND SEQUENCING OF THE BOILERS. THE CONTROLS SHALL
MONITOR OUTSIDE AIR, HOT WATER SUPPLY AND HOT WATER RETURN TEMPERATURES. THE BOILER CONTROLS SHALL
START/STOP THE INDIVIDUAL BOILER CIRCULATION PUMPS CP-2.
ON A CALL FOR DOMESTIC WATER HEATING, THE PUMP CP-7 SHALL BE STARTED AND A DOMESTIC HOT WATER HEATING DEMAND
SIGNAL SHALL BE SENT TO THE BOILER CONTROL SYSTEM. THIS WILL ALLOW THE BOILERS TO FIRE TO MAINTAIN DOMESTIC
WATER HEATING PRIORITY. PUMP CP-7 SHALL RUN CONTINUOUSLY.
WALL MOUNTED ZONE THERMOSTATS SHALL CONTROL ZONE VALVES AT EACH ZONE MANIFOLD TO MAINTAIN SPACE
TEMPERATURE.
04/13/2020
07/29/2020
TF/JH
GENERAL CONTRACTOR
Janckila Construction Inc.
75 Buckskin Drive
Carbondale, CO 81623
T 970.963.7239
F 970.963.7239
STRUCTURAL ENGINEER
Albright and Associates
402 Park Ave., Unit A
Basalt, CO 81621
T 970.927.4363
CIVIL ENGINEER
Roaring Fork Engineering
592 Highway 133,
Carbondale, CO 81623
T 970.948.7474
MEP ENGINEER
Bighorn Consulting Enginners, Inc.
386 Indian Road
Grand Junction, CO 81501
T 970.241.8709
ACOUSTIC CONSULTANT
Acentech
33 Moulton Street
Cambridge, MA 02138
T 617.499.8000
F 617.499.8074
61
7
W
E
S
T
B
L
E
E
K
E
R
S
T
R
E
E
T
AS
P
E
N
AS
P
E
N
,
C
O
8
1
6
1
1
Drawing Title:
Drawing No:
Phase:
Architect
29 Stanhope Street
3rd Floor
Boston, MA 02116
T 617.426.0995
F 617.426.0998
MONICA PONCE DE LEON
STUDIO, INC.
DATE & ISSUE DESCRIPTION BY CHECK
ISSUE/
REVISION
Project Number:
19-046
RE
S
I
D
E
N
C
E
03/02/2020 PERMIT SET BCE BCE1
M3-3
DETAILS
MECHANICAL
- SIDEWALL DISCHARGE
BATHROOM EXHAUST FAN DETAIL
N.T.S.
AIREX
H
A
U
S
T
GRILLE CEILING
FAN
CABINET ABOVE
EXHAUST
DAMPER
W/ BACKDRAFT
WALL CAP
DUCT
CEILING FLOOR
OR ROOF
EF
CONNECTION
REFRIGERANT GAUGE
CONTROL
CONDUIT - POWER AND
REFRIGERANT LIQUID LINE
INDICATOR
SIGHT GLASS WITH MOISTURE
WITH INSULATION
REFRIGERANT SUCTION LINE
VALVE
BACK-SEATED REFRIGERANT
CONDENSING UNIT
- SLAB MOUNTED AT GRADE
AIR-COOLED CONDENSING UNIT
N.T.S.
FILTER-DRYER
FAN GUARD
AIR HANDLING UNIT OR
AIR CONDITIONING UNIT
ADAPTOR
SECTION
DRAIN PAN
COOLING COIL
4"
*
DRAIN PLUG
MIMIMUM SIZE 1". ABOVE 1"
FULL SIZE ON UNIT CONNECTION.
TO CONDENSATE PUMP
EXTEND FULL SIZE.
NOT TO SCALE
CONDENSATE DRAIN DETAIL
FLAT ROOF CAP
ROOF
FLASHING
ROOF
EXHAUST DUCT CEILING/ROOF
FRAMING
EXHAUST
FAN
CEILING
GRILLECEILING
ROOF CURB
1'
-
6
"
MI
N
.
CEILING EXHAUST FAN DETAIL
NOT TO SCALE
EXHAUST DUCT
1
1
/
2
W
USE THIS DESIGN
WHERE ROUND 90
ELS ARE SHOWN
ON PLANS
ROUND 90 ELBOW
CL
LC
CONSTRUCTION OF 90 ELBOWS
"W"
"W
"
"W
"
"W"
TURN VANES-SEE DETAIL
THIS SHEET
USE THIS DESIGN
WHERE SQUARE 90
ELS ARE SHOWN ON
PLANS OR IF SPACE
CONDITIONS DO NOT
PERMIT INSTALLATION
OF ROUND 90 ELLS
SQUARE 90 ELBOW
"W"
"W""
W
"
"W"
CL
LC
USE THIS DESIGN
WHERE ROUND 45
ELBOWS ARE SHOWN
ON PLANS
1 1/
2
W
TURN VANES-SEE
DETAIL THIS SHEET
ON PLANS
ELBOWS ARE SHOWN
WHERE ROUND 45
USE THIS DESIGN
SQUARE 45 ELBOW
CONSTRUCTION OF 45 ELBOWS
ROUND 45 ELBOW
AIR
FLOW
"W"
"W"
BRANCH
MAIN
ROUND BRANCH TAKEOFF
SQUARE BRANCH TAKEOFF
MAIN
BRANCH
FLOW
AIR
CONSTRUCTION OF BRANCH TAKEOFFS FROM MAIN
TURN VANES-SEE
DETAIL THIS SHEET
SLOPE NOT TO EXCEED
1" IN 4"
TYPICAL RECTANGULAR TRANSITION TYPICAL RECTANGULAR TO ROUND TRANSITION
1" IN 4"
SLOPE NOT TO EXCEED
RECTANGULAR DUCT
ROUND DUCT
AIR
FLOW
MAIN
SPLITTER DAMPER
TURN
VANES
BRANCH
DAMPER ADJUSTMENT
ROD & LOCK SCREW
TYPICAL SPLITTER DAMPER
DETAILS OF THE LOW VELOCITY DUCT LAYOUT
NO SCALE
1"R
.
2" R
A
D
I
U
S
1" 1"
1"
1
"
DETAIL OF TURN VANES
CONNECTION
LINKAGE
DOUBLE
ACTING BLADES
TYPICAL VOLUME DAMPER
HINGE
POINT
OPERATING SHAFT
FOR QUADRANT OR
MOTOR.
ROOF
CLAMP
FLASING
12" MINIMUM
ABOVE AVERAGE
SNOW ACCUMLATION
COMBUSTION AIR PIPEFLUE EXHAUST PIPE
CONCENTRIC FLAT ROOF
TERMINATION INSTALLATION DETAIL
(TYPICAL FOR HIGH EFFICIENCY GAS FURNACES)
N.T.S.
D
R
A
I
N
V
E
N
T
H
W
R
E
T
U
R
N
L
I
Q
U
I
D
L
I
N
E
L
I
N
E
S
U
C
T
I
O
N
ATTACHED HOT WATER COIL DETAIL
HORIZONTAL FAN COIL UNIT WITH
N.T.S.
H
O
T
W
A
T
E
R
C
O
I
L
S
U
P
P
L
Y
D
R
A
I
N
T
O
O
U
T
S
I
D
E
O
R
F
L
O
O
R
3
/
4
"
P
V
C
D
R
A
I
N
F
C
PAN
F
C
R
O
O
F
R
A
F
T
E
R
S
R
O
D
T
O
H
A
N
G
E
R
C
O
N
N
E
C
T
I
O
N
F
L
E
X
I
B
L
E
R
E
T
U
R
N
DRIP
R
E
F
R
I
G
.
R
E
F
R
I
G
.
F
A
N
C
O
I
L
U
N
I
T
H
W
S
U
P
P
L
Y
FROM GAS
SUPPLY
FROM GAS
SUPPLY
6" TRAP
(DRIP LEG)
TO EQUIPMENT/
CONTROLS
GROUND JOINT
UNION
MANUAL SHUT-OFF VALVE
WITH AN 1/8" N.P.T. PLUGGED
TAPPING ACCESSIBLE FOR
TEST GAGE CONNECTION TO
BE INSTALLED UPSTREAM OF
THE GAS SUPPLY CONNECTION
TO THE APPLIANCE.
GAS
COCK
GAS CONNECTION TO EQUIPMENT DETAIL
NOT TO SCALE
GRADE
GRADE
FINISHED
ABOVE
18" MIN.
EXHAUST
AIR
INTAKE
AIR
AIR
INTAKE
WALL
OUTSIDE
CLAMP
BUSHING
REDUCING
ELBOW
AIR
EXHAUST
AIR
INTAKE
CONCENTRIC WALL TERMINATION
INSTALLATION DETAIL
(TYPICAL FOR HIGH EFFICIENCY GAS FURNACES)
N.T.S.
N.T.S.
(TYPICAL FOR HIGH EFFICIENCY GAS FURNACES)
TERMINATION INSTALLATION DETAIL
CONCENTRIC SLOPED ROOF
FLUE EXHAUST PIPE COMBUSTION AIR PIPE
SNOW ACCUMLATION
ABOVE AVERAGE
12" MINIMUM ROOF
PITCHED
FLASING
SHEET METAL STRAP
CLAMP
8" CONCRETE BLOCK
PROVIDE LINTEL OVER
LOUVER AS SHOWN ON
ARCHITECTURAL DWG.
NOT TO SCALE
EXPOSED LINKAGE
CAULK & SEAL
ALL AROUND
ADJUSTABLE INTAKE/EXHAUST
LOUVER
BIRD SCREEN
MOTORIZED LOUVER DETAIL
MOTORIZED ACTUATOR
EXTERIOR WALL
REDUCER
6"X4" PVC
STONE
CRUSHED EARTH
4"
6 MIL. VAPOR BARRIER
CONCRETE SLAB
GROUND FLOOR
PVC
4" SCH. 40
12
"
ROOF
SLAB, VAPOR BARRIER, AND CRUSHED STONE.
1. REFERENCE ARCHITECTURAL DRAWINGS FOR DETAILS OF
NOTE:
NOT TO SCALE
RADON VENT DETAIL
EXHAUST FAN: EQUIVALENT TO FANTECH - RN3 INLINE RADON FAN
2. EXHAUST FAN TO RUN CONTINUOUSLY
PVC
4" SCH. 40
MINIMUM 3"Ø PERFORATED PIPING INSTALLED
DIRECTLY IN AGGREGATE TO CREATE LOOP AS
SHOWN ON PLUMBING DRAWINGS
RECOMMENDED PRODUCT ADS SINGLE WALL
CORRUGATED, PERFORATED PIPING
120V/1PH/60HZ, 141 WATTS, 2 AMPS, 1.42 E.S.P., 377 CFM, 2782 RPM
FAN SHALL RUN CONTINUOUSLY, PROVIDE WITH POWER DISCONNECT
04/13/2020
07/29/2020
TF/JH