Loading...
HomeMy WebLinkAboutFile Documents.617 W Bleeker St.0062-2019-BRES (31)06/22/2020 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 07/29/2020 TF/JH FIRE SPRINKLERS REQUIRED GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL GENERAL NOTES A0-00 GRAPHIC SYMBOLS 001 A1.1 1 2 3 4 SECTION KEY DETAIL KEY INTERIOR ELEVATION KEY PLUMBING FIXTURE KEY EQUIPMENT KEY FINISH TYPE KEY AIR CONDITIONING ACOUSTIC CEILING TILE - (TYPE) ADJUSTABLE AGGREGATED ABOVE FINISHED FLOOR ALTERNATED ALUMINUM APPROXIMATELY ARCHITECTURAL ANODIZED BOTTOM OF CURB BRICK COURSE BOARD BUILDING BLOCKING BEAM BOTTOM OF CONCRETE BOTTOM BOTTOM OF WALL BUILT UP ROOF BUILT UP CARPET - (TYPE) CABINET CATCH BASIN CEMENT CORNER GUARD CAST IRON CAST IN PLACE CHROME CONTROL JOINTS CLOSET CEILING CLEAR CONCRETE MASONRY UNIT CONVENIENCE OUTLET RECEPTACLE COLUMN COMMAND COMPRESSIBLE CONCRETE CONSTRUCTION CONTINUOS CERAMIC TILE CENTER LINE COLD WATER DIAMETER DETAIL DRINKING FOUNTAIN DIMENSION DIFFUSER DOWN DOOR DRAWING EACH ELECTRICAL FLOOR DEVICE EXPANSION JOINT ELEVATION ELECTRICAL ELEVATOR EMERGENCY ENCLOSURE ELECTRICAL PANEL EQUAL EQUIPMENT EXHAUST EXISTING EXPANSION EXTERIOR EXISTING TO REMAIN FLOOR CLEAN OUT FLOOR DRAIN FIRE EXTINGUISHER ON HOOK FIRE EXTINGUISHER CABINET FINISH FIXTURE FLOOR FLUORESCENT FACE OF CONCRETE FACE OF PRECAST FACE OF MASONRY FEET FOOTING FIELD VERIFY FURNISHED BY OWNER, INSTALLED BY GC GAUGE GALVANIZED GENERAL CONTRACTOR GLASS GRANITE GYPSUM WALL BOARD GYPSUM HANDICAPPED HALLOW CORE HARDWARE HEIGHT HALLOW METAL HORIZONTAL HEIGHT POINT HOUR HEATER HEATING, VENTING, & AIR CONDITIONING HOT WATER INSIDE DIAMETER INCH OR INCHES INCANDESCENT INCLUDE INSULATION INTERIOR INTERIOR JOINT LAMINATED LAVATORY LOW POINT LIGHTING LOUVER MACHINE MAXIMUM MECHANICAL MEMBRANECE MANUFACTURE MINIMUM MISCELLANEOUS MASONRY OPENING MOUNTED METAL NOT APPLICABLE NOT IN CONTRACT NUMBER NOT TO SCALE OVERALL ON CENTER OUTSIDE DIAMETER OWNER FURNISHED OPENING OPPOSITE OPPOSITE HAND PATCH PAINT - (TYPE) PARALLEL PRECAST CONC PANEL GLASS PERPENDICULAR PLATE PLASTIC LAMINATE - (TYPE) PLASTER PLYWOOD PANEL PROJECTION PAINTED PRESSURE TREATED PARTITION PLYWOOD POLY VINYL CHLORIDE QUARRY TILE QUANTITY AC ACT - 1 ADJ AGG AFF ALT ALUM APPROX ARCH ANOD BOC BCO BD BLDG BLKG BM B.O.C BOT B. O. W BUR B.U. C - 1 CAB CB CEM CG CI C.I.P CHR CJ CL CLG CLR CMU CO COL COMM COMP CONC CONST CONT CT CTR CW DIA DET DF DIM DIF DN DR DWG EA EFD EJ EL ELEC ELEV EMERG ENCL EP EQ EQUIP EXH EX EXP EXT EXR FCR FD FEH FEC FIN FIXT FL FLUOR F.O.C F.O.P FOM FT FTG FV F.B.O GA GALV G.C. GL GRN GWB GWP HCP HCR HDW HT HM HOR HP HR HTR HVAC HW ID IN INCAND INCL INSUL INT INT JT LAM LAV LP LTG LVR MACH MAX MECH MEMB MFR MIN MISC MO MTD MTL NA NIC NO NTS OA OC OD OF OPG OPP OPPH P P-1 PAR PCC PGL PERP PL PL-1 PLAS PLWD PNL PROJ PTD PT PTN PLY PVC QT QTY ABBREVIATIONS NTS GRID BUBBLE AND CENTER LINE 3'-6"DIMENSION ANNOTATION LEADER 1 DETAIL SCALE: 3" = 1'-0"DRAWING TITLE A1.1 3 ROOM TAG N NORTH REINFORCED RADIUS RETURN AIR REFLECTED CEILING PLAN ROOF DRAIN RECEIVING REFRIGERATOR REGISTER REQUIRED REVISION ROOM ROUGH OPENING SOLID CORE SCA SPARRY ON SCREEN SECTION SERVICE SQUARE FOOT SHEET SIMILAR SPECIFICATIONS STAINLESS STEEL SOLID SURFACE - (TYPE) STANDARD STEEL STRUCTURAL STORAGE SUSPENDED TREADS TRENCH DRAIN TELEPHONE TEMPORARY/ TEMPERED TEMPERED GLASS THICK TOP OF CONCRETE TOP OF FOOTING TOP OF PLATFORM TOP OF RAILING TOP OF MASONRY TOP OF STEEL TOP OF WALL TYPICAL UNLESS NOTED OTHERWISE VAPOR BARRIER VINYL COMPOSITION TILE VERTICAL VINYL VERIFY IN FIELD VENEER PLASTER WITH WOOD WIDE FLANGE (STEEL BEAM) WIRE GLASS WITHOUT WORKING POINT WATER PROOFING REINF R RA RCP RD RECV REF REG REQ'D REV RM RO SC SCA SCR SECT SERV S.F SHT SIM SPEC S.S SS - 1 STD STL STR STOR SUSP T TD TEL TEMP T.GL THK T.O.C T.O.F T.O.P T.O.R T.O.M T.O.S T.O. W TYP U.N.O V.B VCT VERT VIN V.I.F VP W/ WD WF W.GL W/O W.P WPR CEMENTITIOUS ACOUSTICAL DOOR 1 DOOR NUMBER KEYED NOTE PF-1 EQ-1 F-1 ELEVATION KEY AVERAGEAVG WINDOW NUMBERA A A A7-01 FOYER 101 1 A5-01 1 A4-01 ELEVATION INDICATORLEVEL 1 100.0 GENERAL NOTES 6.ALL GWB SHALL BE 5/8" THICK, UNLESS NOTED OTHERWISE. PROVIDE CEMENT BOARD AT ALL WET LOCATIONS. 2.DIMENSIONS ARE FROM FACE OF FINISHED WALL TO FACE OF FINISHED WALL UNLESS NOTED OTHERWISE. 3.THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD. ANY DISCREPANCIES BETWEEN FIELD CONDITIONS OR DIMENSIONS, AND THOSE INDICATED ON THE DRAWINGS SHALL BE REPORTED TO THE ARCHITECT FOR RESOLUTION PRIOR TO THE CONTINUATION OF WORK. 4.DIMENSIONS HAVE BEEN GIVEN FOR SCALE AND ESTIMATING PURPOSES. ALL FABRICATION DIMENSIONS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHALL MAKE PRECISE FIELD MEASUREMENTS OF ALL CONDITIONS AND FABRICATE ALL NEW COMPONENTS TO FIT PROPERLY INTO THE BUILDING. ANY DISCREPANCY IN DIMENSIONS, WHICH WILL AFFECT THE OUTCOME OF THE WORK SHALL BE REPORTED TO THE ARCHITECT IN SKETCH FORM FOR RESOLUTION PRIOR TO THE COMMENCING OF ANY FABRICATION OR INSTALLATION WORK. DO NOT SCALE DRAWINGS.1. 7. 8.ALL WOOD AND WOOD PRODUCTS SHALL BE FORMALDEHYDE FREE. FORMALDEHYDE FREE PLYWOOD WILL BE SUBSTITUTED BY FORMALDEHYDE FREE MDF W/ PRIOR APPROVAL BY ENVIRONMENTAL CONSULTANT GEORGE RIEGEL, JR., M.D. 5.ALL MATERIALS TO BE INSTALLED IN THE RESIDENCE MUST HAVE PRIOR APPROVAL FROM ENVIRONMENTAL CONSULTANT. 9.ALL ARCHITECTURAL WOODWORK AND CASEWORK MUST BE OF "PREMIUM" GRADE AS SPECIFIED BY AWI STANDARDS. 10.CONTRACTOR OR HIS/HER CONSULTANTS MUST SUBMIT SHOP DRAWINGS, SAMPLES, BROCHURES, ETC. ON ALL ITEMS OF ARCHITECTURAL WOODWORK AND CASEWORK. SHOP DRAWINGS MUST BE OF SUFFICIENT DETAIL IN SCALE TO DETERMINE COMPLIANCE W/ THE INTENT OF THE QUALITY STANDARD SPECIFIED. 11.CONTRACTOR OR HIS/HER CONSULTANTS MUST SUBMIT TWO 12" x 12" SAMPLES OF EACH SURFACE FOR THE ARCHITECT'S APPROVAL PRIOR TO COMMENCEMENT OF WORK. 12.WHENEVER A CONFLICT OF INFORMATION IS FOUND IN THIS PRICING SET, IT SHOULD BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING W/ PRICING. WALL DESIGNATIONS NEW WALL 1 PARTITION TYPE NTS LIGHTING KEY FA FA-1 FB RECESS MOUNTED LED DOWNLIGHT (PROVIDED BY GC) RECESS MOUNTED LED WET LOCATION DOWNLIGHT (PROVIDED BY GC) RECESS MOUNTED LED WALL WASH (PROVIDED BY GC) LINEAR SURFACE MOUNT LED STRIP UPLIGHT TOP OF CABINET (PROVIDED BY GC) LINEAR LENSED LED STRIP UNDERCABINET (PROVIDED BY GC) FC-1 LINEAR LED STRIP COVE (PROVIDED BY GC) FC-2 FC FD LINEAR LED STRIP VERTICAL MOUNTED AT CABINETS (PROVIDED BY GC) FE LINEAR LED DOWNLIGHT AT CLOSETS (PROVIDED BY GC) WALL SCONCE (PROVIDED BY OWNER)DS-1 WALL SCONCE (PROVIDED BY OWNER) WALL SCONCE (PROVIDED BY OWNER)DS-3 WALL SCONCE (PROVIDED BY OWNER)DS-4 WALL SCONCE (PROVIDED BY OWNER)DS-5 WALL SCONCE (PROVIDED BY OWNER) WALL MOUNTED LED MIRROR LIGHT (PROVIDED BY GC) LARGE SURFACE MOUNT DECORATIVE LED LENSED DOWNLIGHT (PROVIDED BY GC) RECESS MOUNTED LED STAIR LIGHT (PROVIDED BY GC) FF FG FH SURFACE MOUNT LED HIGH OUTPUT DOWNLIGHT AT COURT (PROVIDED BY GC)FI LINEAR LED DOWNLIGHT AT GARAGE (PROVIDED BY GC)FJ LINEAR LED DOWNLIGHT (PROVIDED BY GC)FJ-1 DECORATIVE PENDANT (PROVIDED BY OWNER)DP-1 DECORATIVE PENDANT (PROVIDED BY OWNER)DP-2 DECORATIVE PENDANT (PROVIDED BY OWNER)DP-3 DECORATIVE PENDANT (PROVIDED BY OWNER)DP-4 G.B.GROUND BOX OUTLET SWITCHED (PROVIDED BY GC) G.B.-1 GROUND BOX OUTLET NOT SWITCHED (PROVIDED BY GC) DECORATIVE PENDANT (PROVIDED BY OWNER)DP-5 LIGHTED WARDROBE TUBE LED (PROVIDED BY GC)FK DS-6 DS-2 WALL SCONCE (PROVIDED BY OWNER) WALL SCONCE (PROVIDED BY OWNER) DS-7 DS-8 EXTERIOR WALL SCONCE (PROVIDED BY OWNER) DECORATIVE PENDANT (PROVIDED BY OWNER) DECORATIVE PENDANT (PROVIDED BY OWNER)DP-7 RECESS MOUNTED LED EXTERIOR STAIR LIGHT (PROVIDED BY GC)FXH ES-1 DP-6 DECORATIVE PENDANT (PROVIDED BY OWNER)DP-5B WALL SCONCE (PROVIDED BY OWNER)DS-5B 06/22/2020 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 07/29/2020 TF/JH G:\My Drive\Aspen Survey\2020\200215-17231\200215.gxd -- 02/13/2020 -- 02:59 PM -- Scale 1 : 120.000000 06/22/2020 20.00 f t ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 07/29/2020 TF/JH GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL LAND USE APPROVALS Z0-01 06/22/2020 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 07/29/2020 TF/JH GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL ZONING SUMMARY Z0-02 ZONING ALLOWANCE AND PROJECT SUMMARY PROPOSED DEVELOPMENT SINGLE FAMILY/ SCRAPE AND REPLACE/ NEW CONSTRUCTION CITY OF ASPEN ZONING SUBMISSION PARCEL ID 273512444002 ZONE DISTRICT R-6 SETBACKS EXISTING ALLOWED PROPOSED REFERENCE FRONT N/A 10'14'-1"26.710.040 REAR 10'16' COMBINED FRONT/REAR N/A N/A 26.710.040 26.710.040 SIDE 10'10', 20'26.710.040 COMBINED SIDE 30'30'26.710.040 CORNER LOT 26.710.040 N/A N/A N/A N/A NO SUPPLEMENTAL BREAKDOWN INFO EXISTING REQUIRED PROPOSED REFERENCE NET LEASABLE/ COMM SQ FT N/A 10'26.575.020.I. OPEN SPACE %NO REQUIREMENT PER R-6 SITE COVERAGE 3600 SQ FT MAXIMUM (40%) 26.710.040 26.710.040 N/A N/A ON-SITE PARKING 2 2 26.515.030N/A SITE COVERAGE EXISTING PROPOSED REFERENCE GROSS LOT AREA 9,000 SQ FT 26.710.040 AREA OF BUILDING FOOTPRINT SITE COVERAGE PERCENTAGE 35.73% 26.710.040 26.710.040 N/A N/A TRANSFERABLE DEVELOPMENT RIGHT (TDR)REFERENCE RECEIVED TDR CERTIFICATE SENT TDR CERTIFICATE 26.710.040 LAND VALUE SUMMARY EXISTING REFERENCE LAND 4,080,000 PITKIN COUNTY ASSESSOR IMPROVEMENTS TOTAL 2,058,600 6,138,600 N/A N/A NET LOT AREA CITY OF ASPEN ZONING SUBMISSION ZONE DISTRICT REQUIREMENTS MINIMUM GROSS LOT AREA PER R-6 6,000 26.710.040 MINIMUM NET LOT AREA PER R-6 26.710.0404,500 LOT SIZE PER SURVEY 9000 SQ FT REFERENCE AREAS OF A PARCEL WITH 0%-20% (100% TO BE INCLUDED IN NET LOT AREA 9000 SQ FT 26.575.020-1/ SURVEY TOTAL AREA REDUCTIONS 0 SQ FT NET LOT AREA ALLOWABLE FLOOR AREA CITY OF ASPEN ZONING SUBMISSION ALLOWABLE FLOOR AREA REFERENCE PER R-6, FOR NET LOT AREA BETWEEN 9,000-15,000 SQ FT; 3,660 SQ FT OF FLOOR AREA PLUS 6 SQ FT OF FLOOR AREA FOR EACH ADDITIONAL 100 SQ FT IN NET LOT AREA. 26.710.040 EXEMPTIONS REFERENCE DECK, LOGGIA EXEMPTION 549 SQ FT (ALLOWABLE FLOOR AREA 3,660 X 15%) FLOOR AREA SUMMARY EXISTING GROSS REFERENCE SUBGRADE LEVEL 26.710.040 MAIN LEVEL 26.710.040 ATTIC LEVEL 26.710.040 SECOND LEVEL 26.710.040 TOTAL 9,000 SQ FT 3215.84 SQ FT NO 2 "NON-HISTORIC PROPERTIES WITH A NET LOT AREA OF 9,000 SF OR LARGER THAT CONTAIN ONLY A SINGLE FAMILY RESIDENCE ARE ELIGIBLE TO EXTINGUISH UP TO TWO (2) HISTORIC TDRS." TRANSFERRED TDR CERTIFICATE NO PITKIN COUNTY ASSESSOR PITKIN COUNTY ASSESSOR NO 9000 SQ FT GARAGE EXEMPTION FIRST 250 SQ FT EXEMPT, NEXT 251-500 SQ FT TO EXCLUDE 50% OF AREA.26.575.020.D.7 PER R-6,"NON-HISTORIC PROPERTIES WITH A NET LOT AREA OF 9,000 SF OR LARGER THAT CONTAIN ONLY A SINGLE FAMILY RESIDENCE ARE ELIGIBLE TO EXTINGUISH UP TO TWO (2) HISTORIC TDRS." 26.710.040 LOGGIA, STAIR, AND DECK 26.710.040 EXISTING FLOOR AREA 26.575.020.D.4 3282.13 SQ FT TOTAL ALLOWABLE FLOOR AREA 3,660 SQ FT PER NET LOT AREA, + 2 TDRS (250 SQ FT X2) 500 SQ FT= 4,160 SQ FT TOTAL ALLOWABLE FLOOR AREA 26.710.040 N/A 3451.95 SQ FT 26.710.040GARAGE (ON MAIN LEVEL) N/A PROPOSED FLOOR AREA 380.06 SQ FT 0 SQ FT 4157.85 SQ FT 146.56 SQ FT 1305.80 SQ FT 108.84 SQ FT 2216.59 SQ FT PROPOSED GROSS 3094.93 SQ FT 7794.36 SQ FT 521.56 SQ FT 546.64 SQ FT 108.84 SQ FT 2216.59 SQ FT 0 SQ FT 156.56 SQ FT 1782.60 SQ FT 919.04 SQ FT N/A N/A 2858.20 SQ FT 1782.60 SQ FT 531.56 SQ FT 218.75 SQ FT 1305.80 SQ FT 919.04 SQ FT 06/22/2020 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E 16 ' - 0 " 20'-0"10'-0" PROPERTY LINE GROSS LOT SIZE 9,000 SQ FT NET LOT SIZE 9,000 SQ FT 14 ' - 1 " BUILDING FOOT PRINT 3215.84 SQ FT COVERAGE 35.73% GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL PROPOSED SITE COVERAGE Z0-03 1 PROPOSED SITE COVERAGE SCALE: 3/16" = 1'-0" N 06/22/2020 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 MEDIA ROOM 001 PDR 002 SPORTS COURT 003 WORKOUT ROOM 009 SAUNA 008 STORAGE 007 GUEST BEDROOM 015 GUEST BATHROOM 016 STORAGE 011 LAUNDRY ROOM 005 MECHANICAL ROOM 012 7906.5' BASEMENT LEVEL 7906.5' BASEMENT LEVEL STAIR: 10" TREAD/7.75" RISER STAIR: 10" TREAD/7-5/8" RISER STAIR: 10" TREAD/7.75" RISER 2 2 ATRIUM 004 CORRIDOR 006 CORRIDOR 010 STAIR 014 CORRIDOR 013 001 002 004 005 001 014 013 007 008 011 009 010 003 3 3 3 333 3 3 3 33 2 2 2 2 1 1 11 1 1 1 1 1 1 1 1 1 1 001 002 UP UP UTILITY ROOM 017 006 015 1 2 3 4 5 6 1 2 3 4 9 20'-6"36'-3" 27 ' - 9 3 / 4 " 3'-6 3/4" 23 ' - 1 " 35 ' - 1 3 / 4 " 1'-10" 1 6 ' - 6 3 / 4 " 44'-11 1/4" 3094.93 SQ FT INTERIOR SPACE 1 8 9 295.54 SQ FT 14 ' - 5 " 20'-6" 14 ' - 5 " 1'-10" 14 ' - 5 " 35'-1 3/4" 506.69 SQ FT 26.43 SQ FT 7 14 ' - 5 " 16'-6 3/4" 238.78 SQ FT 6 14 ' - 5 " 44'-11 1/4" 6 44'-11 1/4" 647.81 SQ FT 32 4 127.47 SQ FT 19 ' - 7 " 4' - 7 " 4' - 7 " 27'-9 3/4" 544.66 SQ FT 2 709.90 SQ FT 19 ' - 7 " 36'-3" 7921.5' FINISH GRADE 166.15 SQ FT 3'-6 3/4" 19 ' - 7 " 69.77 SQ FT 7 6 5 8 15 ' - 0 " 15 ' - 0 " 22.76 SQ FT 6' - 6 " 23'-1" 5 332.64 SQ FT 14 ' - 5 " 97.86 SQ FT GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL FLOOR AREA CALCULATIONS Z0-04 1 PROPOSED SUBGRADE LEVEL CALCULATIONS SCALE: 1/8" = 1'-0" N % OF EXPOSED WALL PROPOSED FLOOR AREA CALCULATIONS TOTAL 12.28% EXPOSED WALL AREA (SQ FT)414.24 OVERALL TOTAL WALL AREA (SQ FT)3372.22 9 506.69 8 26.43 7 238.78 6 647.81 5 332.64 166.15 4 3 2 1 295.54 PROPOSED SUBGRADE LEVEL EXPOSED WALL CALCULATIONS FLOOR AREA CALCULATIONS CITY OF ASPEN ZONING SUBMISSION SUBGRADE LEVEL WALL LABEL TOTAL WALL AREA (SQ FT)EXPOSED WALL AREA (SQ FT) SUBGRADE COUNTABLE FLOOR AREA 380.06 SUBGRADE GROSS FLOOR AREA (SQ FT) (3094.93 X 12.28%) SUBGRADE FLOOR AREA CALCULATIONS 3094.93 709.90 544.66 69.77 97.86 22.76 127.47 SUBGRADE LEVEL MAIN LEVEL ATTIC LEVEL SECOND LEVEL LOGGIA, STAIR, AND DECK GARAGE (ON MAIN LEVEL) 380.06 SQ FT 0 SQ FT 4157.85 SQ FT 146.56 SQ FT 1305.80 SQ FT 108.84 SQ FT 2216.59 SQ FT 06/22/2020 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 1 2 3 4 5 6 A B C D E GARAGE 116 MUDROOM 114 DN LAUNDRY ROOM 115 BALCONY 104 POWDER ROOM 107 MASTER BATHROOM 108 7922' MAIN LEVEL 7921.5' GARAGE UP STAIR: 10" TREAD/7.75" RISER STAIR: 10.5" TREAD/7.25" RISER STAIR: 10" TREAD/7.75" RISER TOILET 109 CORRIDOR 110 CLOSET 112CLOSET 111 MASTER BEDROOM 113 CORRIDOR 106 ATRIUM 105 101 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 106 107 108 105 112 113 109 103 104 105 107 108 102 7922' MAIN LEVEL UP STAIR: 10" TREAD/7-5/8" RISER 20 ' - 4 " 2' - 1 0 " 7922' MAIN LEVEL BALCONY 102 104 PACKAGE ROOM 101 1011 102 103ENTRY CLOSET 103 1 111 106 114 1 110 STAIR 55.65 SQ FT 1305.80 SQ FT INTERIOR SPACE GARAGE 521.56 SQ FT TOTAL 146.56 SQ FT COUNTABLE LOGGIA 71.99 SQ FT 1 2 3 4 5 6 A B C D E BEDROOM 1 208 BEDROOM 2 212 BEDROOM 3 216 BATHROOM 1 209 BATHROOM 3 219 BATHROOM 2 213 DN UP 7928' MEZZANINE LEVEL 7932' 2ND LEVEL STAIR: 10" TREAD/7.5" RISER STAIR: 10-1/2" TREAD/6-7/8" RISER CORRIDOR 210 CLOSET 211 CORRIDOR 214 CLOSET 215 CORRIDOR 217 CLOSET 218 CORRIDOR 220 LIVING ROOM 222 ENTRY 205 BAR 206 PDR 204 DINING ROOM 203 BALCONY 202 DECK 224 HOT TUB 223 CORRIDOR 221 CORRIDOR 207 PLANTER 225 2 2 2 2 2 2 2 2 2 203 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 8'-0 1/2" 202 204 205 206 207 201 202 203 204 205 201 210 209 208 207 7928' MEZZANINE LEVEL 209 208 206 KITCHEN 201 DECK 419.00 SQ FT 2216.59 SQ FT INTERIOR SPACE GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL FLOOR AREA CALCULATIONS Z0-05 2 PROPOSED SECOND LEVEL CALCULATIONS SCALE: 1/8" = 1'-0" N 1 PROPOSED MAIN LEVEL CALCULATIONS SCALE: 1/8" = 1'-0" N SECOND LEVEL COUNTABLE FLOOR AREA SECOND LEVEL GROSS FLOOR AREA FLOOR AREA CALCULATIONS CITY OF ASPEN ZONING SUBMISSION SECOND LEVEL FLOOR AREA CALCULATIONS MAIN LEVEL COUNTABLE FLOOR AREA MAIN LEVEL GROSS FLOOR AREA FLOOR AREA CALCULATIONS CITY OF ASPEN ZONING SUBMISSION MAIN LEVEL FLOOR AREA CALCULATIONS PROPOSED DECK STAIR LOGGIA CALCULATIONS LOGGIA DECK EXEMPT LOGGIA DECK STAIR FLOOR AREA LOGGIA DECK STAIR COUNTABLE FLOOR AREA GARAGE COUNTABLE FLOOR AREA GARAGE GROSS FLOOR AREA GARAGE FLOOR AREA CALCULATIONS STAIR PROPOSED FLOOR AREA CALCULATIONS TOTAL SUBGRADE LEVEL MAIN LEVEL ATTIC LEVEL SECOND LEVEL LOGGIA, STAIR, AND DECK GARAGE (ON MAIN LEVEL) 2216.59 SQ FT 2216.59 SQ FT 1305.80 SQ FT 1305.80 SQ FT PROPOSED DECK STAIR LOGGIA CALCULATIONS LOGGIA DECK EXEMPT LOGGIA DECK STAIR FLOOR AREA LOGGIA DECK STAIR COUNTABLE FLOOR AREA GARAGE COUNTABLE FLOOR AREA GARAGE GROSS FLOOR AREA GARAGE FLOOR AREA CALCULATIONS STAIR PROPOSED FLOOR AREA CALCULATIONS TOTAL SUBGRADE LEVEL MAIN LEVEL ATTIC LEVEL SECOND LEVEL LOGGIA, STAIR, AND DECK GARAGE (ON MAIN LEVEL) 55.65 SQ FT 419.00 SQ FT 549 SQ FT 0 SQ FT 521.56 SQ FT 71.99 SQ FT 146.56 SQ FT 380.06 SQ FT 0 SQ FT 4157.85 SQ FT 146.56 SQ FT 1305.80 SQ FT 108.84 SQ FT 2216.59 SQ FT 55.65 SQ FT 419.00 SQ FT 549 SQ FT 0 SQ FT 521.56 SQ FT 71.99 SQ FT 146.56 SQ FT 380.06 SQ FT 0 SQ FT 4157.85 SQ FT 146.56 SQ FT 1305.80 SQ FT 108.84 SQ FT 2216.59 SQ FT 06/22/2020 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 ATTIC 301 DN 7937' ATTIC LEVEL STAIR: 10" TREAD/7.5" RISER 1 301 1 2 3 4 5 6 A B C D E 108.84 SQ FT INTERIOR SPACE GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL FLOOR AREA CALCULATIONS Z0-06 ATTIC LEVEL COUNTABLE FLOOR AREA ATTIC LEVEL GROSS FLOOR AREA FLOOR AREA CALCULATIONS CITY OF ASPEN ZONING SUBMISSION ATTIC LEVEL FLOOR AREA CALCULATIONS 1 PROPOSED ATTIC LEVEL CALCULATIONS SCALE: 1/8" = 1'-0" N 108.84 SQ FT 108.84 SQ FT PROPOSED DECK STAIR LOGGIA CALCULATIONS LOGGIA DECK EXEMPT LOGGIA DECK STAIR FLOOR AREA LOGGIA DECK STAIR COUNTABLE FLOOR AREA GARAGE COUNTABLE FLOOR AREA GARAGE GROSS FLOOR AREA GARAGE FLOOR AREA CALCULATIONS STAIR PROPOSED FLOOR AREA CALCULATIONS TOTAL SUBGRADE LEVEL MAIN LEVEL ATTIC LEVEL SECOND LEVEL LOGGIA, STAIR, AND DECK GARAGE (ON MAIN LEVEL) 55.65 SQ FT 419.00 SQ FT 549 SQ FT 0 SQ FT 521.56 SQ FT 71.99 SQ FT 146.56 SQ FT 380.06 SQ FT 0 SQ FT 4157.85 SQ FT 146.56 SQ FT 1305.80 SQ FT 108.84 SQ FT 2216.59 SQ FT 06/22/2020 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 60 ' - 9 3 / 4 " 59'-7 1/4" 60 ' - 9 3 / 4 " 59'-2 1/2" GARAGE 531.56 SQ FT 1782.60 SQ FT INTERIOR SPACE 18'-3 3/4"21'-0" 25 ' - 3 3 / 4 " 16 ' - 6 " 19 ' - 0 " 62 ' - 9 1 / 2 " 59'-2 1/2" 21'-0" 59'-7 1/4" 10 ' - 0 " 21'-0"14'-5 3/4" 17'-6" 22 ' - 9 3 / 4 " 19 ' - 0 " 14'-6" 25 ' - 3 3 / 4 " 919.04 SQ FT INTERIOR SPACE DECK 218.75 SQ FT GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL FLOOR AREA CALCULATIONS Z0-07 1 EXISTING MAIN LEVEL CALCULATIONS SCALE: 1/8" = 1'-0" N 2 EXISTING UPPER LEVEL CALCULATIONS SCALE: 1/8" = 1'-0" N MAIN LEVEL COUNTABLE FLOOR AREA MAIN LEVEL GROSS FLOOR AREA FLOOR AREA CALCULATIONS CITY OF ASPEN ZONING SUBMISSION MAIN LEVEL FLOOR AREA CALCULATIONS EXISTING DECK CALCULATIONS DECK EXEMPT DECK FLOOR AREA DECK COUNTABLE FLOOR AREA GARAGE COUNTABLE FLOOR AREA GARAGE GROSS FLOOR AREA GARAGE FLOOR AREA CALCULATIONS EXISTING FLOOR AREA CALCULATIONS TOTAL MAIN LEVEL SECOND LEVEL DECK GARAGE (ON MAIN LEVEL) 1782.60 SQ FT 1782.60 SQ FT 531.56 SQ FT 156.56 SQ FT 218.75 SQ FT 549 SQ FT 0 SQ FT 0 SQ FT 2858.20 SQ FT 156.56 SQ FT 1782.60 SQ FT SECOND LEVEL COUNTABLE FLOOR AREA SECOND LEVEL GROSS FLOOR AREA FLOOR AREA CALCULATIONS CITY OF ASPEN ZONING SUBMISSION SECOND LEVEL FLOOR AREA CALCULATIONS EXISTING DECK CALCULATIONS DECK EXEMPT DECK FLOOR AREA DECK COUNTABLE FLOOR AREA GARAGE COUNTABLE FLOOR AREA GARAGE GROSS FLOOR AREA GARAGE FLOOR AREA CALCULATIONS EXISTING FLOOR AREA CALCULATIONS TOTAL MAIN LEVEL SECOND LEVEL DECK GARAGE (ON MAIN LEVEL) 531.56 SQ FT 156.56 SQ FT 218.75 SQ FT 549 SQ FT 0 SQ FT 0 SQ FT 2858.20 SQ FT 156.56 SQ FT 1782.60 SQ FT 919.04 SQ FT 919.04 SQ FT 919.04 SQ FT 919.04 SQ FT 06/22/2020 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 7921.27 SURVEY POINT 7921.40 SURVEY POINT 7921.59 SURVEY POINT 7920.84 SURVEY POINT 7921.21 SURVEY POINT 7921.35 SURVEY POINT 7921.03 SURVEY POINT 7921.15 SURVEY POINT 7922.02 SURVEY POINT 7922.17 SURVEY POINT 7922.37 SURVEY POINT 7922.23 SURVEY POINT 7922.35 SURVEY POINT 7922.63 SURVEY POINT 7921.65 SURVEY POINT 7921.76 SURVEY POINT 7921.56 SURVEY POINT 7920.98 SURVEY POINT 7920.62 SURVEY POINT 7920.93 SURVEY POINT 7920.68 SURVEY POINT 7920.37 SURVEY POINT 7921.64 SURVEY POINT 7922.17 SURVEY POINT 7922.17 SURVEY POINT 7922.62 SURVEY POINT 7923.27 SURVEY POINT 7923.32 SURVEY POINT 7922.97 SURVEY POINT 7922.84 SURVEY POINT 7922.80 SURVEY POINT 7922.93 SURVEY POINT 7922.64 SURVEY POINT 7922.41 SURVEY POINT 7922.79 SURVEY POINT 7923.25 SURVEY POINT 7923.38 SURVEY POINT 7923.65 SURVEY POINT 7923.94 SURVEY POINT 7923.63 SURVEY POINT 7923.58 SURVEY POINT 7923.60 SURVEY POINT 7924.94 SURVEY POINT 7925.37 SURVEY POINT 7924.47 SURVEY POINT 7924.40 SURVEY POINT 7924.06 SURVEY POINT 7924.21 SURVEY POINT 7922.95 SURVEY POINT 7921.98 SURVEY POINT 7921.65 SURVEY POINT 7922.17 SURVEY POINT PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E EXISTING STRUCTURE WEST BLEEKER STREET 7924 FINISH GRADE SET TO 7921.5 AT ALL POINTS ALONG EDGE OF PROPOSED RESIDENCE LI N E O F S E T B A C K LINE OF SETBACK LINE OF SETBACK LI N E O F S E T B A C K 7923 7923 19 5 3 1 2 4 8 7 11 9 10 14 12 13 15 16 6 17 18 20 RO O F H E I G H T RO O F H E I G H T 17.5 12 RIDGE 1/2 POINT FOR PITCH 3:12 TO 7:12 1/3 POINT FOR GREATER THAN 7:12 EAVE POINT GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL 4 06/17/2019 PERMIT RESPONSE 2 AK MPdL HEIGHT OVER TOPOGRAPHY Z0-08 1 HEIGHT OVER TOPOGRAPHY DIAGRAM SCALE: 1/8" = 1'-0" N 1 2 ELEVATION LABEL HEIGHT OVER TOPOGRAPHY CITY OF ASPEN ZONING SUBMISSION 3 4 5 6 7 8 ELEVATION OF NATURAL GRADE ELEVATION OF PROPOSED GRADE MOST RESTRICTIVE ROOF HEIGHT OVER TOPOGRAPHY 7921.59' 7921.65' 7921.98' 7923.27' 7922.80' 7922.63' 7922.17' 7921.64' 7921.5' 7921.5' 7921.5' 7921.5' 7921.5' 7921.5' 7921.5' 7921.5' PROPOSED PROPOSED PROPOSED PROPOSED PROPOSED PROPOSED PROPOSED PROPOSED 7946'-6" 7933'-6" 7946'-6" 7936'-0 1/4" 7946'-6" ACTUAL ROOF HEIGHT OVER MOST RESTRICTIVE 25'-0" 12'-0" 25'-0" 14'-6 1/4" 25'-0" 2 HEIGHT MEASUREMENT VIGNETTE SCALE: 1/4" = 1'-0" 10 11 12 13 14 15 16 7921.65' 7921.98' 7923.27' 7922.80' 7922.63' 7922.17' 7921.64' 7921.5' 7921.5' 7921.5' 7921.5' 7921.5' 7921.5' 7921.5' PROPOSED PROPOSED PROPOSED PROPOSED PROPOSED PROPOSED PROPOSED 7945'-0"23'-6" 9 7921.59'7921.5'PROPOSED 7936'-0 1/4"14'-6 1/4" 7942'-0"22'-6" 7944'-0"24'-6" 7946'-6"25'-0" 7946'-6"25'-0" 7946'-6"25'-0" 7946'-6"25'-0" 7945'-6"24'-0" 7946'-6"25'-0" *NOTE DORMER AGGREGATE AREA SHOWN IN LINE HATCH= 215.70 SF ROOF PLANE AGGREGATE AREA SHOWN IN SOLID HATCH= 1840.70 SF DORMER AGGREGATE AREA IS LESS THAN 50% OF ROOF PLANE AREA RIDGE OF DORMERS IS LOWER THAN RIDGE OF ROOF AT ALL POINTS DORMERS SHALL BE EXCLUDED FROM THE CALCULATION PER 26.575.020.F.2.g 17 18 19 7922.63' 7922.17' 7921.64' 7921.5' 7921.5' 7921.5' PROPOSED PROPOSED PROPOSED 7943'-3"21'-9" 20 7921.64'7921.5'PROPOSED 7946'-6"25'-0" 7943'-3"21'-9" 7943'-3"21'-9" 7946'-6"25'-0" 07/30/2020 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 3 10 7 8 12 13 14 16 17 18 19 20 7 8 1 9 10 4 6 12 14 15 16 17 18 19 20 GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL 4 06/17/2019 PERMIT RESPONSE 2 AK MPdL HEIGHT OVER TOPOGRAPHY Z0-09 2 3D AXONOMETRIC SCALE: 1/8" = 1'-0"1 3D AXONOMETRIC SCALE: 1/8" = 1'-0" 1 2 ELEVATION LABEL HEIGHT OVER TOPOGRAPHY CITY OF ASPEN ZONING SUBMISSION 3 4 5 6 7 8 ELEVATION OF NATURAL GRADE ELEVATION OF PROPOSED GRADE MOST RESTRICTIVE ROOF HEIGHT OVER TOPOGRAPHY 7921.59' 7921.65' 7921.98' 7923.27' 7922.80' 7922.63' 7922.17' 7921.64' 7921.5' 7921.5' 7921.5' 7921.5' 7921.5' 7921.5' 7921.5' 7921.5' PROPOSED PROPOSED PROPOSED PROPOSED PROPOSED PROPOSED PROPOSED PROPOSED 7946'-6" 7933'-6" 7946'-6" 7936'-0 1/4" 7946'-6" ACTUAL ROOF HEIGHT OVER MOST RESTRICTIVE 25'-0" 12'-0" 25'-0" 14'-6 1/4" 25'-0" 10 11 12 13 14 15 16 7921.65' 7921.98' 7923.27' 7922.80' 7922.63' 7922.17' 7921.64' 7921.5' 7921.5' 7921.5' 7921.5' 7921.5' 7921.5' 7921.5' PROPOSED PROPOSED PROPOSED PROPOSED PROPOSED PROPOSED PROPOSED 7945'-0"23'-6" 9 7921.59'7921.5'PROPOSED 7936'-0 1/4"14'-6 1/4" 7942'-0"22'-6" 7944'-0"24'-6" 7946'-6"25'-0" 7946'-6"25'-0" 7946'-6"25'-0" 7946'-6"25'-0" 7945'-6"24'-0" 7946'-6"25'-0" 17 18 19 7922.63' 7922.17' 7921.64' 7921.5' 7921.5' 7921.5' PROPOSED PROPOSED PROPOSED 7943'-3"21'-9" 20 7921.64'7921.5'PROPOSED 7946'-6"25'-0" 7943'-3"21'-9" 7943'-3"21'-9" 7946'-6"25'-0" 07/30/2020 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 11 3 7 8 12 13 14 1517 4 5 7 8 1 9 11 12 14 17 19 GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL 4 06/17/2019 PERMIT RESPONSE 2 AK MPdL HEIGHT OVER TOPOGRAPHY Z0-10 2 3D AXONOMETRIC SCALE: 1/8" = 1'-0"1 3D AXONOMETRIC SCALE: 1/8" = 1'-0" 1 2 ELEVATION LABEL HEIGHT OVER TOPOGRAPHY CITY OF ASPEN ZONING SUBMISSION 3 4 5 6 7 8 ELEVATION OF NATURAL GRADE ELEVATION OF PROPOSED GRADE MOST RESTRICTIVE ROOF HEIGHT OVER TOPOGRAPHY 7921.59' 7921.65' 7921.98' 7923.27' 7922.80' 7922.63' 7922.17' 7921.64' 7921.5' 7921.5' 7921.5' 7921.5' 7921.5' 7921.5' 7921.5' 7921.5' PROPOSED PROPOSED PROPOSED PROPOSED PROPOSED PROPOSED PROPOSED PROPOSED 7946'-6" 7933'-6" 7946'-6" 7936'-0 1/4" 7946'-6" ACTUAL ROOF HEIGHT OVER MOST RESTRICTIVE 25'-0" 12'-0" 25'-0" 14'-6 1/4" 25'-0" 10 11 12 13 14 15 16 7921.65' 7921.98' 7923.27' 7922.80' 7922.63' 7922.17' 7921.64' 7921.5' 7921.5' 7921.5' 7921.5' 7921.5' 7921.5' 7921.5' PROPOSED PROPOSED PROPOSED PROPOSED PROPOSED PROPOSED PROPOSED 7945'-0"23'-6" 9 7921.59'7921.5'PROPOSED 7936'-0 1/4"14'-6 1/4" 7942'-0"22'-6" 7944'-0"24'-6" 7946'-6"25'-0" 7946'-6"25'-0" 7946'-6"25'-0" 7946'-6"25'-0" 7945'-6"24'-0" 7946'-6"25'-0" 17 18 19 7922.63' 7922.17' 7921.64' 7921.5' 7921.5' 7921.5' PROPOSED PROPOSED PROPOSED 7943'-3"21'-9" 20 7921.64'7921.5'PROPOSED 7946'-6"25'-0" 7943'-3"21'-9" 7943'-3"21'-9" 7946'-6"25'-0" 07/30/2020 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 06/22/2020 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E EXISTING STRUCTURE WEST BLEEKER STREET DRIVEWAY LI N E O F S E T B A C K LINE OF SETBACK LINE OF SETBACK LI N E O F S E T B A C K TREE 1 TO REMAIN TYPE CONIFER 5" DIAMETER 8' DRIP-LINE TREE 2 TO REMAIN TYPE CONIFER 10" DIAMETER 9' DRIP-LINE TREE 3 TO REMAIN TYPE CONIFER 14" DIAMETER 14' DRIP-LINE TREE 4 TO REMAIN TYPE CONIFER 22" DIAMETER 23' DRIP-LINE TREE 5 TO REMAIN TYPE DECIDUOUS 10" DIAMETER 12' DRIP-LINE TREE 6 TO BE REMOVED TYPE DECIDUOUS 7" DIAMETER 25' DRIP-LINE TREE 8 TO BE REMOVED TYPE DECIDUOUS 9" DIAMETER 14' DRIP-LINE TREE 9 TO BE REMOVED TYPE DECIDUOUS 10" DIAMETER 11' DRIP-LINE TREE 7 TO BE REMOVED TYPE DECIDUOUS 8" DIAMETER 12' DRIP-LINE TREE 21 TO REMAIN TYPE DECIDUOUS 8" DIAMETER 13' DRIP-LINE TREE 16 TO REMAIN TYPE DECIDUOUS 6" DIAMETER 10' DRIP-LINE TREE 17 TO REMAIN TYPE DECIDUOUS 7" DIAMETER 10' DRIP-LINE TREE 18 TO REMAIN TYPE DECIDUOUS 10" DIAMETER 10' DRIP-LINE TREE 15 TO REMAIN TYPE DECIDUOUS 14" DIAMETER 21' DRIP-LINE TREE 20 TO REMAIN TYPE DECIDUOUS 10" DIAMETER 13' DRIP-LINE TREE 19 TO REMAIN TYPE DECIDUOUS 7" DIAMETER 9' DRIP-LINE TREE 28 TO REMAIN TYPE DECIDUOUS 16" DIAMETER 22' DRIP-LINE TREE 30 TO REMAIN TYPE CONIFER 5" DIAMETER 6' DRIP-LINE TREE 29 TO REMAIN TYPE DECIDUOUS 8" DIAMETER 16' DRIP-LINE TREE 31 TO REMAIN TYPE DECIDUOUS 13" DIAMETER 15' DRIP-LINE TREE 33 TO REMAIN TYPE DECIDUOUS 8" DIAMETER 12' DRIP-LINE TREE 32 TO REMAIN TYPE DECIDUOUS 10" DIAMETER 18' DRIP-LINE TREE 34 TO REMAIN TYPE DECIDUOUS 12" DIAMETER 13' DRIP-LINE TREE 35 TO REMAIN TYPE DECIDUOUS 10" DIAMETER 10' DRIP-LINE TREE 37 TO REMAIN TYPE CONIFER 9" DIAMETER 9' DRIP-LINE TREE 36 TO REMAIN TYPE CONIFER 11" DIAMETER 11' DRIP-LINE TREE 39 TO REMAIN TYPE DECIDUOUS 10" DIAMETER 11' DRIP-LINE TREE 38 TO REMAIN TYPE DECIDUOUS 14" DIAMETER 14' DRIP-LINE TREE 14 TO REMAIN TYPE DECIDUOUS 32" DIAMETER 23' DRIP-LINE TREE 11 TO BE REMOVED TYPE DECIDUOUS 7" DIAMETER 13' DRIP-LINE TREE 10 TO BE REMOVED TYPE DECIDUOUS 8" DIAMETER 14' DRIP-LINE TREE 13 TO REMAIN TYPE CONIFER 23" DIAMETER 18' DRIP-LINE TREE 12 TO BE REMOVED TYPE DECIDUOUS 7" DIAMETER 20' DRIP-LINE TREE 23 TO BE REMOVED TYPE CONIFER 12" DIAMETER 15' DRIP-LINE TREE 25 TO BE REMOVED TYPE DECIDUOUS 10" DIAMETER 21' DRIP-LINE TREE 26 TO BE REMOVED TYPE CONIFER 19" DIAMETER 28' DRIP-LINE TREE 27 TO BE REMOVED TYPE DECIDUOUS 19" DIAMETER 27' DRIP-LINE TREE 22 TO BE REMOVED TYPE CONIFER 5" DIAMETER 7' DRIP-LINE TREE 24 TO BE REMOVED TYPE DECIDUOUS 12" DIAMETER 16' DRIP-LINE GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL SITE/BASE PLAN A0-02 1 SITE/ BASE PLAN SCALE: 1/8" = 1'-0" N TREE MITIGATION CALCULATIONS CITY OF ASPEN WELS SUBMISSION TREE #TYPE TRUNK DIAMETER TRUNK RADIUS TRUNK AREA MITIGATION COST TOTAL MITIGATION COST 10 ASPEN 8 4 50.24 11 ASPEN 7 3.5 38.465 12 ASPEN 7 3.5 38.465 22 ASPEN 5 2.5 19.625 $883.13 23 ASPEN 12 6 113.04 $5,086.80 24 SPRUCE 12 6 113.04 $5,086.80 25 ASPEN 10 5 78.54 26 ASPEN 19 9.5 283.385 $12,752.33 27 ASPEN 19 9.5 283.385 $12,752.33 TOTAL $56,211.99 6 ASPEN 7 3.5 38.48 $45.00 $1,731.60 7 ASPEN 8 4 50.27 $2,262.15 8 ASPEN 9 4.5 63.62 $2,862.90 9 ASPEN 10 5 78.54 $3,534.30 $45.00 $45.00 $45.00 $45.00 $45.00 $45.00 $45.00 $45.00 $45.00 $45.00 $45.00 $45.00 $2,262.15 $1,731.60 $1,731.60 $3,534.30 06/22/2020 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 07/29/2020 TF/JH 2113.45 SQ FT INTERIOR SPACE MEDIA ROOM 001 PDR 002 SPORTS COURT 003 WORKOUT ROOM 009 SAUNA 008 STORAGE 007 GUEST BEDROOM 015 GUEST BATHROOM 016 STORAGE 011 LAUNDRY ROOM 005 MECHANICAL ROOM 012 7906.5' BASEMENT LEVEL 7906.5' BASEMENT LEVEL STAIR: 10" TREAD/7.75" RISER STAIR: 10" TREAD/7-5/8" RISER STAIR: 10" TREAD/7.75" RISER 2 2 ATRIUM 004 CORRIDOR 006 CORRIDOR 010 STAIR 014 CORRIDOR 013 001 002 004 005 001 014 013 007 008 011 009 010 003 3 3 3 333 3 3 3 33 2 2 2 2 1 1 11 1 1 1 1 1 1 1 1 1 1 001 002 UP UP UTILITY ROOM 017 006 015 1023.38 SQ FT INTERIOR SPACE GARAGE 116 MUDROOM 114 DN LAUNDRY ROOM 115 BALCONY 104 POWDER ROOM 107 MASTER BATHROOM 108 7922' MAIN LEVEL 7921.5' GARAGE UP STAIR: 10" TREAD/7.75" RISER STAIR: 10.5" TREAD/7.25" RISER STAIR: 10" TREAD/7.75" RISER TOILET 109 CORRIDOR 110 CLOSET 112CLOSET 111 MASTER BEDROOM 113 CORRIDOR 106 ATRIUM 105 101 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 106 107 108 105 112 113 109 103 104 105 107 108 102 7922' MAIN LEVEL UP STAIR: 10" TREAD/7-5/8" RISER 20 ' - 4 " 2' - 1 0 " 7922' MAIN LEVEL BALCONY 102 104 PACKAGE ROOM 101 1011 102 103ENTRY CLOSET 103 1 111 106 114 1 110 2129.14 SQ FT INTERIOR SPACE BEDROOM 1 208 BEDROOM 2 212 BEDROOM 3 216 BATHROOM 1 209 BATHROOM 3 219 BATHROOM 2 213 DN UP 7928' MEZZANINE LEVEL 7932' 2ND LEVEL STAIR: 10" TREAD/7.5" RISER STAIR: 10-1/2" TREAD/6-7/8" RISER CORRIDOR 210 CLOSET 211 CORRIDOR 214 CLOSET 215 CORRIDOR 217 CLOSET 218 CORRIDOR 220 LIVING ROOM 222 ENTRY 205 BAR 206 PDR 204 DINING ROOM 203 BALCONY 202 DECK 224 HOT TUB 223 CORRIDOR 221 CORRIDOR 207 PLANTER 225 2 2 2 2 2 2 2 2 2 203 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 8'-0 1/2" 202 204 205 206 207 201 202 203 204 205 201 210 209 208 207 7928' MEZZANINE LEVEL 209 208 206 KITCHEN 201 104.52 SQ FT INTERIOR SPACE ATTIC 301 DN 7937' ATTIC LEVEL STAIR: 10" TREAD/7.5" RISER 1 301 GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL FIRE AREA CALCULATIONS A0-03 1 BASEMENT LEVEL CALCULATIONS SCALE: 1/8" = 1'-0" N MAIN LEVEL COUNTABLE FLOOR AREA BASEMENT LEVEL GROSS FLOOR AREA PROPOSED GROSS AREA TOTAL 2113.45 SQ FT 1023.38 SQ FT 5360.40 SQ FT 1 MAIN LEVEL CALCULATIONS SCALE: 1/8" = 1'-0" N 1 SECOND LEVEL CALCULATIONS SCALE: 1/8" = 1'-0" N 1 ATTIC LEVEL CALCULATIONS SCALE: 1/8" = 1'-0" N ATTIC LEVEL COUNTABLE FLOOR AREA SECOND LEVEL GROSS FLOOR AREA 2119.05 SQ FT 104.52 SQ FT 06/22/2020 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 07/29/2020 TF/JH FIRE SPRINKLERS REQUIRED NFPA 13D 2780 SQ.FT. 1820 SQ.FT. 2190 SQ. FT. 6894 SQ. FT. 2,780 sf 1,818 sf 2,192 sf PROPERTY LINE PR O P E R T Y L I N E PROPERTY LINE PR O P E R T Y L I N E DRIVEWAY IMPERVIOUS LI N E O F S E T B A C K LINE OF SETBACK LINE OF SETBACK LI N E O F S E T B A C K WALKWAY IMPERVIOUS WALKWAY IMPERVIOUS SNOWMELT ZONE 1 135.28 SF SNOWMELT ZONE 2 152.09 SF SNOWMELT ZONE 3 669.52 SF WEST BLEEKER STREET GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL RREMP PLAN A0-04 1 CMP PLAN SCALE: 1/8" = 1'-0" N 06/22/2020 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 07/29/2020 TF/JH 1 A3-01 A3-01 1 1 A3-02 1 A3-02 1 A3-03 A3-03 1 1 A3-04 1 A3-04 LF-2LF-2LF-2 LF-2 LF-2 LF-2 LF-2 LF-2 LF-2 LF-2 LF-2 LF-2 TYPE 'LF-2' AIM SOURCE AWAY FROM HOUSE TYPE 'LF-2' AIM SOURCE AWAY FROM HOUSE LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-1 LF-2 LF-2 LF-2 LF-2 LF-2 LF-2 EXTERIOR LIGHTING PLAN A0-05 1 EXTERIOR LIGHTING PLAN SCALE: 3/16" = 1'-0" N EXTERIOR LIGHTING KEY + SCHEDULE DESIGNATION LF1 LF2 MANUFACTURER HINKLEY LANDSCAPE LIGHTING HINKLEY LANDSCAPE LIGHTING MODEL NUMBER 1548 BZ 1518 BZ MODEL NAME PIZA ATLANTIS LAMP LED LED COLOR TEMP 2700 K 2700 K WATTS 2.4 W 2.4 W FOOT CANDLE (3') 0.38 0.27 HEIGHT 15" 22" GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL 06/22/2020 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 07/29/2020 TF/JH DOWNSPOUT PROPERTY LINE PR O P E R T Y L I N E PROPERTY LINE PR O P E R T Y L I N E DRIVEWAY IMPERVIOUS LI N E O F S E T B A C K LINE OF SETBACK LINE OF SETBACK LI N E O F S E T B A C K GROUNDCOVER IRRIGATED GRAVEL W/ COLORADO BUFF FLAGSTONE PAVERS TURF/GRASS IRRIGATED NATIVE PLANTS LOW INTENSITY IRRIGATION GROUNDCOVER IRRIGATED WALKWAY IMPERVIOUS GROUNDCOVER IRRIGATED WALKWAY IMPERVIOUS PROPOSED NEW FENCE 10 ' - 0 " 5'-0" 45 ' - 0 " 6' - 0 1 / 2 " 30 ' - 8 " 5'-0" 20'-0"10'-0" WEST BLEEKER STREET COLORADO BUFF FLAGSTONE PERVIOUS PAVERS COLORADO BUFF FLAGSTONE PERVIOUS PAVERS DOWNSPOUT DOWNSPOUT DOWNSPOUT 10 ' - 0 " INTERNAL ROOF DRAIN/ DOWNSPOUT 1 A3-01 A3-01 1 1 A3-02 1 A3-02 1 A3-03 A3-03 1 1 A3-04 1 A3-04 GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL SITEPLAN A1-00 1 SITE PLAN SCALE: 1/8" = 1'-0" N 06/22/2020 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 07/29/2020 TF/JH 08/17/2020 08/17/2020 justinh SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 FIRE SPRINKLERS REQUIRED HR GR GR DE ET ET DE Separate elevator permit req'd from NWCCOG SA SA CO V There are 2 dryers in the laundry room. Provide makeup air if the total exhausted airflow exceeds 200cfm. (2015 IMC 504.6) V GR GR HRSI 2015 IRC Code References V Bathroom and balanced whole house mechanical ventilation req. Ordinance 40, 2016 CO Carbon monoxide detector per City Ordinance 41 series 2016 DE Clothes dryer exhaust, 2015 IMC 504. Makeup air required if over 200 CFM EE Emergency escape required, 2015 IRC R310.1 EU Enclosed usable space under stairs shall be 775 in Gyp, 2015 IRC R302.7 ET Exhausts terminate 3ft from prop line and openings, 10ft from intakes, 2015 IMC 501.3.1 GR Guardrails, 36in min high, 4in max opening; required at 30in drop any point w/in 36in horizontally, 2015 IRC R312 GR Guardrails, 36in min high, 4in max opening; required at 30in drop any point w/in 36in horizontally, 2015 IRC R312 HR Handrails 34in-38in high, 2015 IRC R311.7.8 HR Handrails 34in-38in high, 2015 IRC R311.7.8 MA Make up air required if hood exhausts greater than 400 CFM, 2015 IMC 505.2 SG Safety glazing required, 2015 IRC R308.4 SA Smoke alarms installed to NFPA 72 requirements, 2015 IRC R314 SI Stairway illumination, 2015 IRC R303.7 INSTALLATION INSTRUCTIONS REQUIRED ON SITE AT TIME OF INSPECTION Installation per IMC 914 08/17/2020 08/17/2020 justinh HR GR DE ET Electric vehicle charging (IRC 309.6). Newly constructed one- or two-family dwellings and townhouses with a dedicated attached or detached garage shall facilitate future installation and use of electric vehicle chargers. For each dwelling unit, a 208/240-volt individual branch circuit or a listed raceway to accommodate a future individual branch circuit shall be installed. The raceway shall not be less than trade size 1 (nominal 1-inch inside diameter). The raceway shall originate at the main service or subpanel and shall terminate into a listed cabinet, box or other enclosure, and in close proximity to the proposed location of the electric vehicle charger. Raceways are required to be continuous at enclosed, inaccessible or concealed areas and spaces. The service panel or subpanel circuit directory shall provide capacity to install a 40-ampere minimum dedicated branch circuit and space(s) reserved to permit installation of a branch circuit overcurrent device. Electrical vehicle supply equipment shall be installed in accordance with NFPA 70. 20 Exception: Additions and alterations to existing one- or two-family dwellings and townhomes constructed per the IRC are exempt from this requirement. V V V SGSG SG SG SG Separate elevator permit req'd from NWCCOG If the dryer exhaust duct exceeds 35' of developed length, either provide installation instructions for a dryer model or UL 705 listed dryer booster fan at the time of inspection that will permit your proposed length . (2015 IMC 504.8.4) 1' - 1 0 " SG SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 FIRE SPRINKLERS REQUIRED ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 EE SA Openings between the garage and residence shall be equipped with solid wood doors not less than 1 3/8 inches (35 mm) in thickness, solid or honeycomb core steel doors not less than 1 3/8 inches (35 mm) thick, or 20-minute fire-rated doors, equipped with a self-closing device (IRC 302.5.1) 2015 IRC Code References Bathroom and balanced whole house mechanical ventilation req. Ordinance 40, 2016 Carbon monoxide detector per City Ordinance 41 series 2016 Clothes dryer exhaust, 2015 IMC 504. Makeup air required if over 200 CFM EE Emergency escape required, 2015 IRC R310.1 EU Enclosed usable space under stairs shall be 775 in Gyp, 2015 IRC R302.7 Exhausts terminate 3ft from prop line and openings, 10ft from intakes, 2015 IMC 501.3.1 Guardrails, 36in min high, 4in max opening; required at 30in drop any point w/in 36in horizontally, 2015 IRC R312 GR Guardrails, 36in min high, 4in max opening; required at 30in drop any point w/in 36in horizontally, 2015 IRC R312 Handrails 34in-38in high, 2015 IRC R311.7.8 HR Handrails 34in-38in high, 2015 IRC R311.7.8 MA Make up air required if hood exhausts greater than 400 CFM, 2015 IMC 505.2 SG Safety glazing required, 2015 IRC R308.4 Smoke alarms installed to NFPA 72 requirements, 2015 IRC R314 Stairway illumination, 2015 IRC R303.7 HR GR 1 2 3 4 5 6 A B C D E BEDROOM 1 208 BEDROOM 2 212 BEDROOM 3 216 BATHROOM 1 209 BATHROOM 3 219 BATHROOM 2 213 DN UP 7928' MEZZANINE LEVEL 7932' 2ND LEVEL STAIR: 10" TREAD/7.5" RISER STAIR: 10-1/2" TREAD/6-7/8" RISER CORRIDOR 210 CLOSET 211 CORRIDOR 214 CLOSET 215 CORRIDOR 217 CLOSET 218 CORRIDOR 220 LIVING ROOM 222 ENTRY 205 BAR 206 PDR 204 DINING ROOM 203 BALCONY 202 DECK 224 HOT TUB 223 CORRIDOR 221 CORRIDOR 207 PLANTER 225 2 2 2 2 2 2 2 2 2 203 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 21'-11" 16 ' - 3 " 4' - 0 " 3'-0"3'-0" 3'-0" 13 ' - 0 " 13'-7 1/2"13'-8 1/2"11'-6" 8' - 1 1 / 2 " 7'-3 1/2" 8' - 1 1 / 2 " 7'-4" 8'-0 1/2" 6'-8" 10 ' - 1 1 1 / 2 " 30'-0" 38 ' - 0 " 40 ' - 7 " 45 ' - 0 " 69 ' - 1 0 " 60'-0" 30 ' - 8 " 44 ' - 0 " 57 ' - 2 " 5'-0" 202 204 205 206 207 201 202 203 204 205 201 210 209 208 207 7928' MEZZANINE LEVEL 209 208 206 KITCHEN 201 1 A3-01 A3-01 1 1 A3-02 1 A3-02 1 A3-03 A3-03 1 1 A3-04 1 A3-04 13 ' - 0 " GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL SECOND LEVEL FLOOR PLAN A1-03 1 SECOND LEVEL FLOOR PLAN SCALE: 1/4" = 1'-0" N 06/22/2020 SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 FIRE SPRINKLERS REQUIRED HR GR EU HR HR GR GR MA V V V V EE EE EE SA SA SA SA CO Pool cover listed to ASTM F-1346 req'd in compliance with ISPSC ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 SI SI Separate elevator permit req'd from NWCCOG INSTALLATION INSTRUCTIONS REQUIRED ON SITE AT TIME OF INSPECTION Ortal front facing DV fireplace appliance 2015 IRC Code References Bathroom and balanced whole house mechanical ventilation req. Ordinance 40, 2016 Carbon monoxide detector per City Ordinance 41 series 2016 Clothes dryer exhaust, 2015 IMC 504. Makeup air required if over 200 CFM EE Emergency escape required, 2015 IRC R310.1 EU Enclosed usable space under stairs shall be 775 in Gyp, 2015 IRC R302.7 Exhausts terminate 3ft from prop line and openings, 10ft from intakes, 2015 IMC 501.3.1 Guardrails, 36in min high, 4in max opening; required at 30in drop any point w/in 36in horizontally, 2015 IRC R312 GR Guardrails, 36in min high, 4in max opening; required at 30in drop any point w/in 36in horizontally, 2015 IRC R312 Handrails 34in-38in high, 2015 IRC R311.7.8 HR Handrails 34in-38in high, 2015 IRC R311.7.8 MA Make up air required if hood exhausts greater than 400 CFM, 2015 IMC 505.2 SG Safety glazing required, 2015 IRC R308.4 Smoke alarms installed to NFPA 72 requirements, 2015 IRC R314 Stairway illumination, 2015 IRC R303.7 07/29/2020 TF/JH ATTIC 301 DN 7937' ATTIC LEVEL STAIR: 10" TREAD/7.5" RISER 1 38 ' - 0 " 40 ' - 7 " 45 ' - 0 " 69 ' - 1 0 " 60'-0" 30 ' - 8 " 44 ' - 0 " 57 ' - 2 " 5'-0" 11 ' - 7 1 / 2 " 8'-7 1/2" 3'-4" 301 1 2 3 4 5 6 A B C D E 1 A3-01 A3-01 1 1 A3-02 1 A3-02 1 A3-03 A3-03 1 1 A3-04 1 A3-04 GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL ATTIC LEVEL FLOOR PLAN A1-04 1 ATTIC LEVEL FLOOR PLAN SCALE: 1/4" = 1'-0" N 06/22/2020 SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 FIRE SPRINKLERS REQUIRED HR SG ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 SA CO SI 2015 IRC Code References Bathroom and balanced whole house mechanical ventilation req. Ordinance 40, 2016 Carbon monoxide detector per City Ordinance 41 series 2016 Clothes dryer exhaust, 2015 IMC 504. Makeup air required if over 200 CFM EE Emergency escape required, 2015 IRC R310.1 EU Enclosed usable space under stairs shall be 775 in Gyp, 2015 IRC R302.7 Exhausts terminate 3ft from prop line and openings, 10ft from intakes, 2015 IMC 501.3.1 Guardrails, 36in min high, 4in max opening; required at 30in drop any point w/in 36in horizontally, 2015 IRC R312 GR Guardrails, 36in min high, 4in max opening; required at 30in drop any point w/in 36in horizontally, 2015 IRC R312 Handrails 34in-38in high, 2015 IRC R311.7.8 HR Handrails 34in-38in high, 2015 IRC R311.7.8 MA Make up air required if hood exhausts greater than 400 CFM, 2015 IMC 505.2 SG Safety glazing required, 2015 IRC R308.4 Smoke alarms installed to NFPA 72 requirements, 2015 IRC R314 Stairway illumination, 2015 IRC R303.7 07/29/2020 TF/JH 08/17/2020 Snow stops required where snow can slide onto potentially occupied areas such as walkways, parking areas, etc. or do damage to property such as utility meters - IBC 1513/COA 8.20.020(z). ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 08/17/2020 justinh 1 A3-01 A3-01 1 1 A3-02 1 A3-02 1 A3-03 A3-03 1 1 A3-04 1 A3-04 MEDIA ROOM 001 PDR 002 SPORTS COURT 003 WORKOUT ROOM 009 STORAGE 007 GUEST BEDROOM 015 GUEST BATHROOM 016 STORAGE 011 LAUNDRY ROOM 005 MECHANICAL ROOM 012 ATRIUM 004 CORRIDOR 006 CORRIDOR 010 STAIR 014 CORRIDOR 013 13'-6" 19'-6" 14'-0" 14'-0" 13'-6" 13'-6" 13'-6" 13'-6" SAUNA 008 13'-6" 13'-6" 13'-6" FJ-1FJ-1 FJ-1 FJ-1 FC-1 FA FA FA FA FC FC ALL TYPE 'FC' UPLIGHT MOUNT @ TOP OF MILLWORK DS-1 DS-1 DS-1 FC FC - 1 G.B.G.B. FA-1 FF FI FI FI FI FI FI FI FI FI FI FI FI FI FI FI DS-2 DS-2 DS-2 DS-2 DS-2 FJ-1FJ-1 DS-2 FJ-1 DS-2 DS-2 DS-2 FE FA FA FA FAFA FA FH FH FH FH FA FXH FE FB FBFBFA FA-1 FF G.B. G.B.-1 G.B.-1 FJ-1 FJ-1 FJ-1 FJ-1 FC-1 FC-1 FC-1 FH FH FH 14'-0" 14'-0" FC-1 FJ-1 'FC-1' FIXTURE MOUNTED UNDER CABINETS UTILITY ROOM 01713'-6" FXH FXH FJ-1 FJ-1 FA FA 10'-0" 4' - 7 1 / 4 " EQ EQ EQ EQ 4' - 9 7 / 8 " 8'-1 1/8" 5'-0"5'-0"3'-1 3/4"2'-0"2'-0" 2' - 0 " 7' - 0 " 2'-9"8'-11" TYPE 'FC-1' MOUNT UNDER SHELF TYPE 'FF' MOUNT ABOVE MIRROR EQ 2' - 8 " 10'-0"8'-1 3/4" TYPE 'FF' MOUNT ABOVE MIRROR TYPE 'FE' SURFACE MOUNT AT CLOSET CLG EQ OPEN TO ABOVE PENDANTS DROP FROM GROUND LEVEL CEILING OVERLAPPING STAIRS SEE A1-07 DS - 2 G.B.-1 FC-1 FA FA-1 FB RECESS MOUNTED LED DOWNLIGHT (PROVIDED BY GC) RECESS MOUNTED LED WET LOCATION DOWNLIGHT (PROVIDED BY GC) RECESS MOUNTED LED WALL WASH (PROVIDED BY GC) LINEAR SURFACE MOUNT LED STRIP UPLIGHT TOP OF CABINET (PROVIDED BY GC) LINEAR LENSED LED STRIP UNDERCABINET (PROVIDED BY GC) FC-1 LINEAR LED STRIP COVE (PROVIDED BY GC)FC-2 FC FD LINEAR LED STRIP VERTICAL MOUNTED AT CABINETS (PROVIDED BY GC) FE LINEAR LED DOWNLIGHT AT CLOSETS (PROVIDED BY GC) WALL SCONCE (PROVIDED BY OWNER)DS-1 WALL SCONCE (PROVIDED BY OWNER) WALL SCONCE (PROVIDED BY OWNER)DS-3 WALL SCONCE (PROVIDED BY OWNER)DS-4 WALL SCONCE (PROVIDED BY OWNER)DS-5 WALL SCONCE (PROVIDED BY OWNER) WALL MOUNTED LED MIRROR LIGHT (PROVIDED BY GC) LARGE SURFACE MOUNT DECORATIVE LED LENSED DOWNLIGHT (PROVIDED BY GC) RECESS MOUNTED LED STAIR LIGHT (PROVIDED BY GC) FF FG FH SURFACE MOUNT LED HIGH OUTPUT DOWNLIGHT AT COURT (PROVIDED BY GC)FI LINEAR LED DOWNLIGHT AT GARAGE (PROVIDED BY GC)FJ LINEAR LED DOWNLIGHT (PROVIDED BY GC)FJ-1 DECORATIVE PENDANT (PROVIDED BY OWNER)DP-1 DECORATIVE PENDANT (PROVIDED BY OWNER)DP-2 DECORATIVE PENDANT (PROVIDED BY OWNER)DP-3 DECORATIVE PENDANT (PROVIDED BY OWNER)DP-4 G.B.GROUND BOX OUTLET SWITCHED (PROVIDED BY GC) G.B.-1 GROUND BOX OUTLET NOT SWITCHED (PROVIDED BY GC) DECORATIVE PENDANT (PROVIDED BY OWNER)DP-5 LIGHTED WARDROBE TUBE LED (PROVIDED BY GC)FK DS-6 DS-2 WALL SCONCE (PROVIDED BY OWNER) WALL SCONCE (PROVIDED BY OWNER) DS-7 DS-8 EXTERIOR WALL SCONCE (PROVIDED BY OWNER) DECORATIVE PENDANT (PROVIDED BY OWNER) DECORATIVE PENDANT (PROVIDED BY OWNER)DP-7 RECESS MOUNTED LED EXTERIOR STAIR LIGHT (PROVIDED BY GC)FXH ES-1 DP-6 DECORATIVE PENDANT (PROVIDED BY OWNER)DP-5B WALL SCONCE (PROVIDED BY OWNER)DS-5B BASEMENT LEVEL RCP A1-06 1 BASEMENT LEVEL REFLECTED CEILING PLAN SCALE: 1/4" = 1'-0" N LIGHTING KEY 1. UNLESS OTHERWISE INDICATED IN SPEC SHEET - ALL FIXTURES SHALL BE PROVIDED DIMMABLE. 2. UNLESS OTHERWISE INDICATED ON SPEC SHEET - ALL FIXTURES WITH INTEGRATED LAMPS SHALL BE LED, 2,700K, 90CRI. 3. DECORATIVE FIXTURES INDICATED TO BE PROVIDED BY OWNER SHALL HAVE INCANDESCENT LAMPS - PROVIDED BY CONTRACTOR, EXCEPT WHERE OTHERWISE STATED IN SPEC SHEET. 4. OVERALL LIGHTING CONTROL SYSTEM TO BE COORDINATED WITH ELECTRICAL ENGINEER AND ARCHITECT. 5. ALL ROOMS SHALL BE PROVIDED FOR WALL PANEL SWITCHES W/ USER OPERABLE DIMMERS ASSOCIATED TO ALL LAMPS IN THE ROOM. SETTINGS AND NUMBER OF ZONES TO BE COORDINATED WITH ELECTRICAL ENGINEER AND ARCHITECT. 6. WALL PANEL SWITCH TO BE LCD KEYPAD, AFFIXED AT 4'-3" FROM FINISH FLOOR. COORDINATE WITH ARCHITECT FOR PLACEMENT PER SPACE. 7. WHERE INDICATED, GROUND BOXES SHALL BE SWITCHED AT WALL PANEL. 8. WHERE FIXTURE KEY INDICATES RECESS MOUNTED - CONTRACTOR TO PROVIDE FOR MOUNTING ACCESSORIES NECESSARY FOR FLUSH MOUNTING WITH WALL FINISH. 9. FIXTURES RECESS MOUNTED IN WET LOCATIONS SHALL BE SEALED AND LENSED AS INDICATED ON SPECS. LIGHTING GENERAL NOTES GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL 06/22/2020 SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 FIRE SPRINKLERS REQUIRED A minimum of 75% of all lamps installed in permanent light fixtures must be high efficacy in dwelling units (2015 IECC R404.1) Recessed luminaires installed in building thermal envelope shall be sealed and IC-rated – IECC sec R402.4.5 Any recessed light fixtures in contact with insulation must be IC rated. ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 07/29/2020 TF/JH 20 ' - 4 " 2' - 1 0 " 1 A3-01 A3-01 1 1 A3-02 1 A3-02 1 A3-03 A3-03 1 1 A3-04 1 A3-04 PACKAGE ROOM 101 GARAGE 116 MUDROOM 114 LAUNDRY ROOM 115 CORRIDOR 104 ENTRY CLOSET 103 POWDER ROOM 107MASTER BATHROOM 108 TOILET 109 CORRIDOR 110 CLOSET 112 CLOSET 111 MASTER BEDROOM 113 CORRIDOR 102 CORRIDOR 106 ATRIUM 105 DRAPERY POCKET R1' - 0 " 0 ' - 6 " 11'-0" FC-2 (28'-0") DS-4 G.B. G.B. DS-4 20'-3" 9'-0" FB FB FG FG DS-5 FF FF FA-1 DS-5 DS-5B 9'-0" FK FK FK FK FK FK FK DS-6 DS-6 DS-6 DS-6 DS-6 FH FH FHFHFHFH FK 9'-0" 8'-0" FA FAFA FJ-1FC-1 9'-0" FF FJ-1 FC-1 FJ-1 FC-1 DS-6 DS-6 DS-6 DS-6 FJ FJ FJ FJ 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" ES-1 ES-1 DP-4 FXH FXH FXH FXH FXH FXHFXH ES-1 OPEN TO ABOVE PENDANTS MOUNTED AT CEILING 9'-0" FJ-1 FJ-1 FA FA-1 FB RECESS MOUNTED LED DOWNLIGHT (PROVIDED BY GC) RECESS MOUNTED LED WET LOCATION DOWNLIGHT (PROVIDED BY GC) RECESS MOUNTED LED WALL WASH (PROVIDED BY GC) LINEAR SURFACE MOUNT LED STRIP UPLIGHT TOP OF CABINET (PROVIDED BY GC) LINEAR LENSED LED STRIP UNDERCABINET (PROVIDED BY GC) FC-1 LINEAR LED STRIP COVE (PROVIDED BY GC)FC-2 FC FD LINEAR LED STRIP VERTICAL MOUNTED AT CABINETS (PROVIDED BY GC) FE LINEAR LED DOWNLIGHT AT CLOSETS (PROVIDED BY GC) WALL SCONCE (PROVIDED BY OWNER)DS-1 WALL SCONCE (PROVIDED BY OWNER) WALL SCONCE (PROVIDED BY OWNER)DS-3 WALL SCONCE (PROVIDED BY OWNER)DS-4 WALL SCONCE (PROVIDED BY OWNER)DS-5 WALL SCONCE (PROVIDED BY OWNER) WALL MOUNTED LED MIRROR LIGHT (PROVIDED BY GC) LARGE SURFACE MOUNT DECORATIVE LED LENSED DOWNLIGHT (PROVIDED BY GC) RECESS MOUNTED LED STAIR LIGHT (PROVIDED BY GC) FF FG FH SURFACE MOUNT LED HIGH OUTPUT DOWNLIGHT AT COURT (PROVIDED BY GC)FI LINEAR LED DOWNLIGHT AT GARAGE (PROVIDED BY GC)FJ LINEAR LED DOWNLIGHT (PROVIDED BY GC)FJ-1 DECORATIVE PENDANT (PROVIDED BY OWNER)DP-1 DECORATIVE PENDANT (PROVIDED BY OWNER)DP-2 DECORATIVE PENDANT (PROVIDED BY OWNER)DP-3 DECORATIVE PENDANT (PROVIDED BY OWNER)DP-4 G.B.GROUND BOX OUTLET SWITCHED (PROVIDED BY GC) G.B.-1 GROUND BOX OUTLET NOT SWITCHED (PROVIDED BY GC) DECORATIVE PENDANT (PROVIDED BY OWNER)DP-5 LIGHTED WARDROBE TUBE LED (PROVIDED BY GC)FK DS-6 DS-2 WALL SCONCE (PROVIDED BY OWNER) WALL SCONCE (PROVIDED BY OWNER) DS-7 DS-8 EXTERIOR WALL SCONCE (PROVIDED BY OWNER) DECORATIVE PENDANT (PROVIDED BY OWNER) DECORATIVE PENDANT (PROVIDED BY OWNER)DP-7 RECESS MOUNTED LED EXTERIOR STAIR LIGHT (PROVIDED BY GC)FXH ES-1 DP-6 DECORATIVE PENDANT (PROVIDED BY OWNER)DP-5B WALL SCONCE (PROVIDED BY OWNER)DS-5B GROUND LEVEL RCP A1-07 1 GROUND LEVEL REFLECTED CEILING PLAN SCALE: 1/4" = 1'-0" N LIGHTING KEY 1. UNLESS OTHERWISE INDICATED IN SPEC SHEET - ALL FIXTURES SHALL BE PROVIDED DIMMABLE. 2. UNLESS OTHERWISE INDICATED ON SPEC SHEET - ALL FIXTURES WITH INTEGRATED LAMPS SHALL BE LED, 2,700K, 90CRI. 3. DECORATIVE FIXTURES INDICATED TO BE PROVIDED BY OWNER SHALL HAVE INCANDESCENT LAMPS - PROVIDED BY CONTRACTOR, EXCEPT WHERE OTHERWISE STATED IN SPEC SHEET. 4. OVERALL LIGHTING CONTROL SYSTEM TO BE COORDINATED WITH ELECTRICAL ENGINEER AND ARCHITECT. 5. ALL ROOMS SHALL BE PROVIDED FOR WALL PANEL SWITCHES W/ USER OPERABLE DIMMERS ASSOCIATED TO ALL LAMPS IN THE ROOM. SETTINGS AND NUMBER OF ZONES TO BE COORDINATED WITH ELECTRICAL ENGINEER AND ARCHITECT. 6. WALL PANEL SWITCH TO BE LCD KEYPAD, AFFIXED AT 4'-3" FROM FINISH FLOOR. COORDINATE WITH ARCHITECT FOR PLACEMENT PER SPACE. 7. WHERE INDICATED, GROUND BOXES SHALL BE SWITCHED AT WALL PANEL. 8. WHERE FIXTURE KEY INDICATES RECESS MOUNTED - CONTRACTOR TO PROVIDE FOR MOUNTING ACCESSORIES NECESSARY FOR FLUSH MOUNTING WITH WALL FINISH. 9. FIXTURES RECESS MOUNTED IN WET LOCATIONS SHALL BE SEALED AND LENSED AS INDICATED ON SPECS. LIGHTING GENERAL NOTES GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL 06/22/2020 SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 FIRE SPRINKLERS REQUIRED A minimum of 75% of all lamps installed in permanent light fixtures must be high efficacy in dwelling units (2015 IECC R404.1) Recessed luminaires installed in building thermal envelope shall be sealed and IC-rated – IECC sec R402.4.5 Any recessed light fixtures in contact with insulation must be IC rated. ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 07/29/2020 TF/JH 8'-0 1/2" 1 A3-01 A3-01 1 1 A3-02 1 A3-02 1 A3-03 A3-03 1 1 A3-04 1 A3-04 BEDROOM 1 208 BEDROOM 2 212 BEDROOM 3 216 BATHROOM 1 209 BATHROOM 3 219 BATHROOM 2 213 CORRIDOR 210 CLOSET 211 CORRIDOR 214 CLOSET 215 CORRIDOR 217 CLOSET 218 ENTRY 205 PDR 204 CORRIDOR 202 DECK 224 HOT TUB 223 CORRIDOR 221 CORRIDOR 207 PLANTER 225 FG FG 20'-0" KITCHEN 201 20'-0" 10'-6.5" FH FH FH DS-6DS-6 DS-6DS-6 FG 9'-0" 21'-7"21'-7"21'-7"12'-8" WINDOW HT DS-7 DS-8 G.B.-1 FE FEFE FE FH FH FH DS-8DS-8 DS-7 DS-7 DS-7 DS-7 DS-7 DS-7 DS-7 DS-7 DS-7 DS-7 DS-7 FF FFFF FF FA-1 FA-1 FA-1 8'-0"9'-0" CORRIDOR 220 8'-0" 9'-0" 9'-0"9'-0" 9'-0" 9'-0" DINING ROOM 203 BAR 206 FA-1 FC-1 FC FC FC-1 F C - 1 FC-1 FD FD FD FD FD FD F C 'FC' FIXTURE MOUNTED ON TOP OF UPPER CABINETS 'FC-1' FIXTURE MOUNTED UNDER CABINETS FCFC F C - 1 FH FH DP-2 DP-2 DP-3 DP-2 DP-3 11'-3" CEILING HT @ WALL 8'-6" HT @ CABINET TOP 'FD' VERTICAL MOUNT IN MILLWORK DTL 'FC-1' MOUNT UNDER SHELF 8'-0"10'-5" 19'-6" DP-3 DP-2 DP-2 FXH FXH FXH FXH FXHFXH FXH 'FXH' TO COORDINATE WITH HOT TUB STEP DETAILS DP-1 DP-1 DP-1 DP-5 DP-5 DP-5 DP-5 DP-5 'FD' VERTICAL MOUNT IN MILLWORK DTL 'FC' UPLIGHT MOUNTED @ TOP OF MILLWORK 'FD' VERTICAL MOUNT IN MILLWORK DTL 'FC' UPLIGHT MOUNTED @ TOP OF MILLWORK ES-1 ES-1 ES-1 DP-7 DP-7 DS-6DS-6 DS-6 DS-6 G.B. G.B.-1 G.B. DS-6 DP-6 DP-6 DP-6 FA FA-1 FB RECESS MOUNTED LED DOWNLIGHT (PROVIDED BY GC) RECESS MOUNTED LED WET LOCATION DOWNLIGHT (PROVIDED BY GC) RECESS MOUNTED LED WALL WASH (PROVIDED BY GC) LINEAR SURFACE MOUNT LED STRIP UPLIGHT TOP OF CABINET (PROVIDED BY GC) LINEAR LENSED LED STRIP UNDERCABINET (PROVIDED BY GC) FC-1 LINEAR LED STRIP COVE (PROVIDED BY GC)FC-2 FC FD LINEAR LED STRIP VERTICAL MOUNTED AT CABINETS (PROVIDED BY GC) FE LINEAR LED DOWNLIGHT AT CLOSETS (PROVIDED BY GC) WALL SCONCE (PROVIDED BY OWNER)DS-1 WALL SCONCE (PROVIDED BY OWNER) WALL SCONCE (PROVIDED BY OWNER)DS-3 WALL SCONCE (PROVIDED BY OWNER)DS-4 WALL SCONCE (PROVIDED BY OWNER)DS-5 WALL SCONCE (PROVIDED BY OWNER) WALL MOUNTED LED MIRROR LIGHT (PROVIDED BY GC) LARGE SURFACE MOUNT DECORATIVE LED LENSED DOWNLIGHT (PROVIDED BY GC) RECESS MOUNTED LED STAIR LIGHT (PROVIDED BY GC) FF FG FH SURFACE MOUNT LED HIGH OUTPUT DOWNLIGHT AT COURT (PROVIDED BY GC)FI LINEAR LED DOWNLIGHT AT GARAGE (PROVIDED BY GC)FJ LINEAR LED DOWNLIGHT (PROVIDED BY GC)FJ-1 DECORATIVE PENDANT (PROVIDED BY OWNER)DP-1 DECORATIVE PENDANT (PROVIDED BY OWNER)DP-2 DECORATIVE PENDANT (PROVIDED BY OWNER)DP-3 DECORATIVE PENDANT (PROVIDED BY OWNER)DP-4 G.B.GROUND BOX OUTLET SWITCHED (PROVIDED BY GC) G.B.-1 GROUND BOX OUTLET NOT SWITCHED (PROVIDED BY GC) DECORATIVE PENDANT (PROVIDED BY OWNER)DP-5 LIGHTED WARDROBE TUBE LED (PROVIDED BY GC)FK DS-6 DS-2 WALL SCONCE (PROVIDED BY OWNER) WALL SCONCE (PROVIDED BY OWNER) DS-7 DS-8 EXTERIOR WALL SCONCE (PROVIDED BY OWNER) DECORATIVE PENDANT (PROVIDED BY OWNER) DECORATIVE PENDANT (PROVIDED BY OWNER)DP-7 RECESS MOUNTED LED EXTERIOR STAIR LIGHT (PROVIDED BY GC)FXH ES-1 DP-6 DECORATIVE PENDANT (PROVIDED BY OWNER)DP-5B WALL SCONCE (PROVIDED BY OWNER)DS-5B SECOND LEVEL RCP A1-08 1 SECOND LEVEL REFLECTED CEILING PLAN SCALE: 1/4" = 1'-0" N LIGHTING KEY 1. UNLESS OTHERWISE INDICATED IN SPEC SHEET - ALL FIXTURES SHALL BE PROVIDED DIMMABLE. 2. UNLESS OTHERWISE INDICATED ON SPEC SHEET - ALL FIXTURES WITH INTEGRATED LAMPS SHALL BE LED, 2,700K, 90CRI. 3. DECORATIVE FIXTURES INDICATED TO BE PROVIDED BY OWNER SHALL HAVE INCANDESCENT LAMPS - PROVIDED BY CONTRACTOR, EXCEPT WHERE OTHERWISE STATED IN SPEC SHEET. 4. OVERALL LIGHTING CONTROL SYSTEM TO BE COORDINATED WITH ELECTRICAL ENGINEER AND ARCHITECT. 5. ALL ROOMS SHALL BE PROVIDED FOR WALL PANEL SWITCHES W/ USER OPERABLE DIMMERS ASSOCIATED TO ALL LAMPS IN THE ROOM. SETTINGS AND NUMBER OF ZONES TO BE COORDINATED WITH ELECTRICAL ENGINEER AND ARCHITECT. 6. WALL PANEL SWITCH TO BE LCD KEYPAD, AFFIXED AT 4'-3" FROM FINISH FLOOR. COORDINATE WITH ARCHITECT FOR PLACEMENT PER SPACE. 7. WHERE INDICATED, GROUND BOXES SHALL BE SWITCHED AT WALL PANEL. 8. WHERE FIXTURE KEY INDICATES RECESS MOUNTED - CONTRACTOR TO PROVIDE FOR MOUNTING ACCESSORIES NECESSARY FOR FLUSH MOUNTING WITH WALL FINISH. 9. FIXTURES RECESS MOUNTED IN WET LOCATIONS SHALL BE SEALED AND LENSED AS INDICATED ON SPECS. LIGHTING GENERAL NOTES GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL 06/22/2020 SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 FIRE SPRINKLERS REQUIRED A minimum of 75% of all lamps installed in permanent light fixtures must be high efficacy in dwelling units (2015 IECC R404.1) Recessed luminaires installed in building thermal envelope shall be sealed and IC-rated – IECC sec R402.4.5 Any recessed light fixtures in contact with insulation must be IC rated. ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 07/29/2020 TF/JH 1 A3-01 A3-01 1 1 A3-02 1 A3-02 1 A3-03 A3-03 1 1 A3-04 1 A3-04 ATTIC 301 DS-3 G.B. G.B. DS-3 FA FA-1 FB RECESS MOUNTED LED DOWNLIGHT (PROVIDED BY GC) RECESS MOUNTED LED WET LOCATION DOWNLIGHT (PROVIDED BY GC) RECESS MOUNTED LED WALL WASH (PROVIDED BY GC) LINEAR SURFACE MOUNT LED STRIP UPLIGHT TOP OF CABINET (PROVIDED BY GC) LINEAR LENSED LED STRIP UNDERCABINET (PROVIDED BY GC) FC-1 LINEAR LED STRIP COVE (PROVIDED BY GC)FC-2 FC FD LINEAR LED STRIP VERTICAL MOUNTED AT CABINETS (PROVIDED BY GC) FE LINEAR LED DOWNLIGHT AT CLOSETS (PROVIDED BY GC) WALL SCONCE (PROVIDED BY OWNER)DS-1 WALL SCONCE (PROVIDED BY OWNER) WALL SCONCE (PROVIDED BY OWNER)DS-3 WALL SCONCE (PROVIDED BY OWNER)DS-4 WALL SCONCE (PROVIDED BY OWNER)DS-5 WALL SCONCE (PROVIDED BY OWNER) WALL MOUNTED LED MIRROR LIGHT (PROVIDED BY GC) LARGE SURFACE MOUNT DECORATIVE LED LENSED DOWNLIGHT (PROVIDED BY GC) RECESS MOUNTED LED STAIR LIGHT (PROVIDED BY GC) FF FG FH SURFACE MOUNT LED HIGH OUTPUT DOWNLIGHT AT COURT (PROVIDED BY GC)FI LINEAR LED DOWNLIGHT AT GARAGE (PROVIDED BY GC)FJ LINEAR LED DOWNLIGHT (PROVIDED BY GC)FJ-1 DECORATIVE PENDANT (PROVIDED BY OWNER)DP-1 DECORATIVE PENDANT (PROVIDED BY OWNER)DP-2 DECORATIVE PENDANT (PROVIDED BY OWNER)DP-3 DECORATIVE PENDANT (PROVIDED BY OWNER)DP-4 G.B.GROUND BOX OUTLET SWITCHED (PROVIDED BY GC) G.B.-1 GROUND BOX OUTLET NOT SWITCHED (PROVIDED BY GC) DECORATIVE PENDANT (PROVIDED BY OWNER)DP-5 LIGHTED WARDROBE TUBE LED (PROVIDED BY GC)FK DS-6 DS-2 WALL SCONCE (PROVIDED BY OWNER) WALL SCONCE (PROVIDED BY OWNER) DS-7 DS-8 EXTERIOR WALL SCONCE (PROVIDED BY OWNER) DECORATIVE PENDANT (PROVIDED BY OWNER) DECORATIVE PENDANT (PROVIDED BY OWNER)DP-7 RECESS MOUNTED LED EXTERIOR STAIR LIGHT (PROVIDED BY GC)FXH ES-1 DP-6 DECORATIVE PENDANT (PROVIDED BY OWNER)DP-5B WALL SCONCE (PROVIDED BY OWNER)DS-5B ATTIC LEVEL RCP A1-09 1 ATTIC LEVEL REFLECTED CEILING PLAN SCALE: 1/4" = 1'-0" N LIGHTING KEY 1. UNLESS OTHERWISE INDICATED IN SPEC SHEET - ALL FIXTURES SHALL BE PROVIDED DIMMABLE. 2. UNLESS OTHERWISE INDICATED ON SPEC SHEET - ALL FIXTURES WITH INTEGRATED LAMPS SHALL BE LED, 2,700K, 90CRI. 3. DECORATIVE FIXTURES INDICATED TO BE PROVIDED BY OWNER SHALL HAVE INCANDESCENT LAMPS - PROVIDED BY CONTRACTOR, EXCEPT WHERE OTHERWISE STATED IN SPEC SHEET. 4. OVERALL LIGHTING CONTROL SYSTEM TO BE COORDINATED WITH ELECTRICAL ENGINEER AND ARCHITECT. 5. ALL ROOMS SHALL BE PROVIDED FOR WALL PANEL SWITCHES W/ USER OPERABLE DIMMERS ASSOCIATED TO ALL LAMPS IN THE ROOM. SETTINGS AND NUMBER OF ZONES TO BE COORDINATED WITH ELECTRICAL ENGINEER AND ARCHITECT. 6. WALL PANEL SWITCH TO BE LCD KEYPAD, AFFIXED AT 4'-3" FROM FINISH FLOOR. COORDINATE WITH ARCHITECT FOR PLACEMENT PER SPACE. 7. WHERE INDICATED, GROUND BOXES SHALL BE SWITCHED AT WALL PANEL. 8. WHERE FIXTURE KEY INDICATES RECESS MOUNTED - CONTRACTOR TO PROVIDE FOR MOUNTING ACCESSORIES NECESSARY FOR FLUSH MOUNTING WITH WALL FINISH. 9. FIXTURES RECESS MOUNTED IN WET LOCATIONS SHALL BE SEALED AND LENSED AS INDICATED ON SPECS. LIGHTING GENERAL NOTES GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL 06/22/2020 SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 FIRE SPRINKLERS REQUIRED A minimum of 75% of all lamps installed in permanent light fixtures must be high efficacy in dwelling units (2015 IECC R404.1) Recessed luminaires installed in building thermal envelope shall be sealed and IC-rated – IECC sec R402.4.5 Any recessed light fixtures in contact with insulation must be IC rated. ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 07/29/2020 TF/JH FRONT ELEVATION 25 ' - 0 " 31 ' - 6 " 9' - 9 " LEVEL 1 FINISH FLOOR 7922' 2ND LEVEL FINISH FLOOR 7932' MEZZANINE FINISH FLOOR 7928' ATTIC LEVEL FINISH FLOOR 7937' FINISH GRADE 7921.5' 8' - 0 " 101 108 208207 210 209 201 208 209 3 ' - 1 1 " 3 ' - 1 1 " 3 ' - 1 1 " NATURAL GRADE FINISH GRADE IS 7921.5' LOW POINT ON EXISTING FACADE IS 7921.59' FINISH GRADE IS MORE RESTRICTIVE THAN NATURAL GRADE AT ALL POINTS PITCH IS GREATER THAN 7:12, SHALL BE MEASURED FROM THE GROUND TO THE POINT OF THE ROOF VERTICALLY ONE-THIRD OF THE DISTANCE UP THE EAVE POINT TO THE RIDGE. ONE-THIRD MEASUREMENT AT OR BELOW 25'-0" AT ALL POINTS. 17.5 12 13 ' - 3 " 13'-8"13'-8"13'-8" 38'-9 1/2"9'-2 1/2"12'-0" ABCDE 9 11316 GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL FRONT ELEVATION A2-01 1 FRONT ELEVATION SCALE: 1/4" = 1'-0" 06/22/2020 NORTH ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 07/29/2020 TF/JH LEVEL 1 FINISH FLOOR 7922' 2ND LEVEL FINISH FLOOR 7932' MEZZANINE FINISH FLOOR 7928' ATTIC LEVEL FINISH FLOOR 7937' FINISH GRADE 7921.5' 31 ' - 6 1 / 2 " 21 ' - 9 1 / 2 " 14 ' - 0 " 9' - 6 " REAR ELEVATION 201 114 105104 103 106 203 204 EQ EQ EQ 25 ' - 0 " NATURAL GRADE AT REAR OF EXISTING HOUSE FINISH GRADE IS 7921.5' LOW POINT ON EXISTING FACADE IS 7921.59' FINISH GRADE IS MORE RESTRICTIVE THAN NATURAL GRADE AT ALL POINTS 15.5 12 PITCH IS GREATER THAN 7:12, SHALL BE MEASURED FROM THE GROUND TO THE POINT OF THE ROOF VERTICALLY ONE-THIRD OF THE DISTANCE UP THE EAVE POINT TO THE RIDGE. ONE-THIRD MEASUREMENT AT OR BELOW 25'-0" AT ALL POINTS. 27 ' - 0 " A B C D E 511 14 GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL REAR ELEVATION A2-02 1 REAR ELEVATION SCALE: 1/4" = 1'-0" 06/22/2020 SOUTH GR ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 07/29/2020 TF/JH WEST ELEVATION LEVEL 1 FINISH FLOOR 7922' 2ND LEVEL FINISH FLOOR 7932' MEZZANINE FINISH FLOOR 7928' ATTIC LEVEL FINISH FLOOR 7937' FINISH GRADE 7921.5' 31 ' - 6 " 21 ' - 9 " 10 ' - 1 0 1 / 2 " 101 202 102 203 104 10 ' - 1 0 1 / 2 " 4 ' - 0 " 4 ' - 0 " 25 ' - 0 " NATURAL GRADE FINISH GRADE IS 7921.5' LOW POINT ON EXISTING FACADE IS 7921.59' FINISH GRADE IS MORE RESTRICTIVE THAN NATURAL GRADE AT ALL POINTS PITCH IS GREATER THAN 7:12, SHALL BE MEASURED FROM THE GROUND TO THE POINT OF THE ROOF VERTICALLY ONE-THIRD OF THE DISTANCE UP THE EAVE POINT TO THE RIDGE. ONE-THIRD MEASUREMENT AT OR BELOW 25'-0" AT ALL POINTS. 17 12 1 2 3 4 5 6 3 11 14 GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL WEST ELEVATION A2-03 1 WEST ELEVATION SCALE: 1/4" = 1'-0"06/22/2020 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 07/29/2020 TF/JH EAST ELEVATION 123456 25 ' - 0 " 21 ' - 9 " 207 205 107 113 31 ' - 6 " LEVEL 1 FINISH FLOOR 7922' 2ND LEVEL FINISH FLOOR 7932' MEZZANINE FINISH FLOOR 7928' ATTIC LEVEL FINISH FLOOR 7937' FINISH GRADE 7921.5' 206 EQ EQ EQ NATURAL GRADE PITCH IS GREATER THAN 7:12, SHALL BE MEASURED FROM THE GROUND TO THE POINT OF THE ROOF VERTICALLY ONE-THIRD OF THE DISTANCE UP THE EAVE POINT TO THE RIDGE. ONE-THIRD MEASUREMENT AT OR BELOW 25'-0" AT ALL POINTS. FINISH GRADE IS 7921.5' LOW POINT ON EXISTING FACADE IS 7921.59' FINISH GRADE IS MORE RESTRICTIVE THAN NATURAL GRADE AT ALL POINTS 8 12 301 4 7 8913 12 15 14 GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL EAST ELEVATION A2-04 1 EAST ELEVATION SCALE: 1/4" = 1'-0"06/22/2020 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 07/29/2020 TF/JH 1 2 3 4 5 6 MEDIA ROOM 001 LAUNDRY ROOM 005 SUBGRADE FINISH FLOOR 7906.5' LEVEL 1 FINISH FLOOR 7922' 2ND LEVEL FINISH FLOOR 7932' MEZZANINE FINISH FLOOR 7928' ATTIC LEVEL FINISH FLOOR 7937' FINISH GRADE 7921.5' STORAGE 011 F - 2PF - 2 MASTER BEDROOM 113 001 CORRIDOR 110 KITCHEN 201 PDR 204CORRIDOR 221 ATTIC 301 003 201 105 1 A4-01 005 1' - 0 " 8' - 0 " 8' - 1 1 / 4 " 8' - 4 " 3' - 0 " 9' - 1 0 1 / 2 " 10 ' - 4 1 / 2 " 3' - 6 " 8' - 7 5 / 8 " 1' - 0 " 19 ' - 5 1 / 4 " 1' - 0 " 2' - 0 " 9' - 0 " 13 ' - 6 " 2' - 0 " 9' - 0 " 13 ' - 6 " WOOD PANELING CORRIDOR 104 F - 3 CORRIDOR 207 STAIR: 10.5" TREAD/7.25" RISER 10 RISERS THIS SEGMENT STAIR: 10-1/2" TREAD/6-7/8" RISER 7 RISERS THIS SEGMENT 8' - 0 " 3' - 6 " 3' - 0 " WOOD PANELING 14 ' - 5 " EQ - 2 EQ - 1 2' - 0 " D3 A4-06 SECTION 1 A3-011SECTION 1 SCALE: 1/4" = 1'-0" GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL 06/22/2020 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 07/29/2020 TF/JH ABCDE LAUNDRY ROOM 115 GARAGE 116 LEVEL 1 FINISH FLOOR 7922' 2ND LEVEL FINISH FLOOR 7932' FINISH GRADE 7921.5' SUBGRADE FINISH FLOOR 7906.5' STORAGE 011 MECHANICAL ROOM 012 008011009 012 CORRIDOR 013 STAIR 014 CORRIDOR 106 LIVING ROOM 222 CORRIDOR 221 DINING ROOM 203 201 110 109 108 107 204 106 103 102 STAIR: 10" TREAD/7-5/8" RISER 11 RISERS THIS SEGMENT 3 A4-09 BAR 206 10 ' - 1 0 1 / 2 " 2' - 6 1 / 2 " 4' - 0 " 4' - 0 " 4' - 1 1 3 / 8 " 8' - 0 " 9' - 9 " 13 ' - 6 " 15 ' - 6 " 14 ' - 0 " 9' - 0 " 1' - 0 " 1' - 0 " 9' - 6 " 1' - 0 " 2' - 0 " 10 ' - 1 0 1 / 2 " 3' - 6 " 7' - 0 " 7' - 0 " 7' - 0 " 19 ' - 5 1 / 4 " 1 A4-03 TONGUE AND GROOVE WOOD PANELING 14 ' - 5 " MASTER BATHROOM 108 SECTION 2 A3-021SECTION 2 SCALE: 1/4" = 1'-0" GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL 06/22/2020 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 07/29/2020 TF/JH 1 2 3 4 5 6 BEDROOM 3 216 GARAGE 116 SPORTS COURT 003 SUBGRADE FINISH FLOOR 7906.5' FINISH GRADE 7921.5' LEVEL 1 FINISH FLOOR 7922' MEZZANINE FINISH FLOOR 7928' ATTIC LEVEL FINISH FLOOR 7937' 2ND LEVEL FINISH FLOOR 7932' PLANTER BED F - 5 F - 7 F - 8 F - 1 012 STAIR 014 6 1/8" CORRIDOR 217 LIVING ROOM 222 DECK 224 PLANTER 225 014 204 207 113 114 107 002001 WORKOUT ROOM 009 GUEST BEDROOM 015 003 207 108 STAIR: 10" TREAD/7-5/8" RISER 11 RISERS THIS SEGMENT STAIR: 10" TREAD/7-5/8" RISER 10 RISERS THIS SEGMENT 1 A4-04 2' - 8 " 8' - 4 " 1' - 6 1 / 8 " 5' - 0 " 9' - 0 " 2' - 8 " 11 ' - 4 " 3' - 0 " 14 ' - 0 " 1' - 0 " 10 ' - 0 " 4' - 0 " 15 ' - 6 " 3' - 6 " 10 ' - 4 " 2' - 4 " 31 ' - 0 " 9' - 0 " 2' - 0 " 19 ' - 6 " 1' - 0 " 9' - 6 " 1' - 0 " 6" LOUVERED WOOD PANELING 14 ' - 5 " 19 ' - 7 " 6' - 0 " SECTION 3 A3-031SECTION 3 SCALE: 1/4" = 1'-0" GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL 06/22/2020 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 07/29/2020 TF/JH ABCDE 106 207 14 ' - 0 " 1' - 0 " 9' - 6 " 1' - 0 " 3' - 6 " 2' - 6 " 13 ' - 6 " 2' - 0 " 9' - 0 " 1' - 0 " 3' - 6 " 13 ' - 6 " 2' - 0 " 10 ' - 4 1 / 2 " 9' - 9 1 / 2 " GUEST BEDROOM 015 MECHANICAL ROOM 012 STORAGE 011 GARAGE 116 MUDROOM 114 21 ' - 9 " MASTER BEDROOM 113 DECK 224 PLANTER 225 GUEST BATHROOM 016 SUBGRADE FINISH FLOOR 7906.5' FINISH GRADE 7921.5' LEVEL 1 FINISH FLOOR 7922' MEZZANINE FINISH FLOOR 7928' ATTIC LEVEL FINISH FLOOR 7937' 2ND LEVEL FINISH FLOOR 7932' 14 ' - 5 " 14 ' - 5 " 105 104 3' - 0 " 11 ' - 0 " 1 A4-07 SECTION 4 A3-041SECTION 4 SCALE: 1/4" = 1'-0" GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL 06/22/2020 min 36" both ways ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 07/29/2020 TF/JH 06/22/2020 R-20 min ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 07/29/2020 TF/JH Section R905.2.7.1 Ice barrier. An ice dam barrier that consists of at least two (2) layers of underlayment cemented together or of a self-adhering polymer modified bitumen sheet shall be used in lieu of normal underlayment and shall extend from the roof eave edge at least six feet inside the exterior wall line as measured along the roof surface, eighteen (18) inches from the centerline of the valley and up twenty-four (24) inches on the vertical wall at a roof and wall juncture. 5/8"5/8" VARIES WALL ANGLE DRYWALL SUSPENSION SYSTEM WOOD BASE, PAINTED FINISH 2 1 / 2 " CONTINUE SOUND ATTENUATION BLANKET TO UNDERSIDE OF DECK WHERE USED VA R I E S FINISHED FLOOR 1/ 2 " VINYL 'Z' SHADOW BEAD SOUND ATTENUATION BLANKET IN DESIGNATED WALLS FIX TO UNDERSIDE OF STRUCTURE 5/8" GWB; LEVEL 5 FINISH WOOD BASE, PAINTED FINISH VINYL 'Z' SHADOW BEAD WOOD STUD WALL 5 8" GWB CEILING; LEVEL 5 FINISH 1 2"VINYL 'Z' SHADOW BEAD 5 8" GWB CEILING; LEVEL 5 FINISH 1 2"VINYL 'Z' SHADOW BEAD 5 8" GWB CEILING; LEVEL 5 FINISH 5/8" GWB; LEVEL 5 FINISH5/8" VARIES 5/8" GWB; LEVEL 5 FINISH WALL ANGLE WOOD STUD WALL DRYWALL SUSPENSION SYSTEM 5 8" GWB CEILING; LEVEL 5 FINISH WOOD BASE, PAINTED FINISH 2 1 / 2 " CONTINUE SOUND ATTENUATION BLANKET TO UNDERSIDE OF DECK WHERE USED VA R I E S FINISHED FLOOR 1/ 2 " VINYL 'Z' SHADOW BEAD 1 2"VINYL 'Z' SHADOW BEAD SOUND ATTENUATION BLANKET IN DESIGNATED WALLS FIX TO UNDERSIDE OF STRUCTURE 5 8" GWB CEILING; LEVEL 5 FINISH TILE UP TO 5'-0" BOND COAT BACKER BOARD 1" WATER PROOF MEMBRANE IN WET AREAS 1 2"VINYL 'Z' SHADOW BEAD 5 8" GWB CEILING; LEVEL 5 FINISH 5/8" VA R I E S 5/8" GWB; LEVEL 5 FINISH WOOD BASE, PAINTED FINISH VINYL 'Z' SHADOW BEAD 5 8" GWB CEILING; LEVEL 5 FINISH 1 2"VINYL 'Z' SHADOW BEAD 5 8" GWB CEILING; LEVEL 5 FINISH WALL ANGLE DRYWALL SUSPENSION SYSTEM FIX TO UNDERSIDE OF STRUCTURE INSULATED SILL PLATE GASKET TREATED 2x4 SOLE PLATE INSULATION FACE OF FOUNDATION WALL 1" CONTINUOUS GAP BETWEEN FOUNDATION AND STUD WALL, TYP PARTITION TYPES A4-02P1PARTITION AT INTERIOR WALLP2PARTITION AT INTERIOR WALLP3PARTITION AT BASEMENT FOUNDATION WALL SCALE: 3"= 1'-0"SCALE: 3"= 1'-0"SCALE: 3"= 1'-0" GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 05/15/2019 RDS SET AK MPdL2 09/24/2019 WELS SET AK MPdL3 10/22/2019 PERMIT SET AK MPdL4 11/15/2019 PERMIT SET AK MPdL5 06/22/2020 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 07/29/2020 TF/JH C-CHANNELS STEEL STUD WOOD STUDS LOUVERED HEAT RELEASE - MIN 124 SQI ORTAL FRONT-FACING CLEAR 110 H FIREPLACE 2' - 7 1 / 2 " 3' - 9 " 3' - 9 " 3' - 0 " 3' - 0 " 3-1/2" WIDE AIR INTAKE - MIN 124 SQI GWP LEVEL 5 FINISH TYP 9 1 3 / 1 6 " 1' - 9 5 / 8 " 3 1 1 / 1 6 " 1' - 7 1 / 2 " 2' - 9 1 / 4 " DIRECT-TEMP VENT PIPE VENT CAP 3 1 / 2 " 6 5 / 1 6 " 1' - 9 3 / 4 " 2' - 1 5 / 1 6 " 2' - 8 3 / 4 " 2' - 7 7 / 8 " 3' - 0 " 3' - 0 " DIRECT-TEMP VENT PIPE VENT CAP LOUVERED HEAT RELEASE - MIN 124 SQI 3-1/2" WIDE AIR INTAKE - MIN 124 SQI WOOD STUDS C-CHANNELS STEEL STUD ORTAL FRONT-FACING CLEAR 110 H 1' - 7 3 / 8 " 1' - 4 3 / 4 " 4 11/16" 3'-7 13/16" 4 11/16" 1'-3 7/16"1'-3 7/16"1'-7 11/16"1'-7 11/16"1'-3 7/16"1'-3 3/8"1'-7 13/16"1'-7 13/16" C-CHANNEL STEEL STUD ORTAL FRONT-FACING CLEAR 110 H FIREPLACE DIRECT-TEMP VENT PIPE PREMIUM GRADE ARCHITECTURAL WOODWORK WOOD STUDS 3' - 4 5 / 8 " 2' - 8 1 5 / 1 6 " CHIMNEY SHROUD - NON-COMBUSTIBLE GWP LEVEL 5 FINISH TYP GWP LEVEL 5 FINISH TYP PREMIUM GRADE ARCHITECTURAL WOODWORK 17 ' - 3 1 / 2 " NICHE FOR TV 2' - 7 1 / 8 " 3' - 0 " 3' - 0 " 1' - 6 5 / 8 " 1' - 5 1 / 2 " 4' - 3 7 / 1 6 " 1' - 0 " 8 3 / 4 " 6" 2" 2" 6" 1' - 0 3 / 4 " 4" 1' - 0 " 8 3 / 4 " 6" 2" 2" 6" 1' - 0 3 / 4 " 4"CHIMNEY SHROUD - NON-COMBUSTIBLE FIREPLACE DETAILS A4-031FIREPLACE DETAILS SCALE: 1/2" = 1'-0" GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL 06/22/2020 INSTALLATION INSTRUCTIONS REQUIRED ON SITE AT TIME OF INSPECTION ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 07/29/2020 TF/JH Chimney shroud to be listed and labeled for use with specific factory built appliance - IFC 603.6.3 10 R I S E R S A T 7 5 / 8 " = 6 ' - 4 1 / 4 " 9 TREADS AT 10" = 7'-6" 3' - 6 " 3 R I S E R S A T 7 5 / 8 " = 1 ' - 1 0 7 / 8 " 3' - 0 " 3' - 6 " 3' - 6 " 1 3/4" STEEL HANDRAIL 3' - 6 " 7919'-7 7/8" 7921'-6" 7913'-2 7/8" D2 A4-04 7909'-6" 10 TREADS AT 10" = 8'-4" 11 R I S E R S A T 7 5 / 8 " = 7 ' - 0 " 3' - 6 " 10 R I S E R S A T 7 5 / 8 " = 6 ' - 4 1 / 4 " 7' - 0 " 3' - 6 " 5' - 4 7 / 8 " 3 R I S E R S A T 7 5 / 8 " = 1 ' - 1 0 7 / 8 " 2 TREADS AT 10" = 1'-8" 5'-0"3'-0" 3 1/8" 6 1 / 8 " 3 R I S E R S A T 7 1 / 4 " = 1 ' - 9 3 / 4 " 2 TREADS AT 10" = 1'-8" 7 1 / 4 " 1 3/4" WOOD HANDRAIL 7921'-6" 7919'-7 7/8" 7913'-2 7/8" 7913'-6" 7921'-6" D1 A4-04 3' - 6 " 3' - 6 " UP UP 10 TREADS AT 10" = 8'-4" 9 T R E A D S A T 1 0 " = 7 ' - 6 " 3'-0" 2 TREADS AT 10" = 1'-8" 1'-5 1/8"3'-0" UP 1 3/4" WOOD HANDRAIL 3' - 0 " 3' - 0 " 3'-0"1'-8" 7921'-6" 7913'-2 7/8"7913'-6"7906'-6" 02 A4-04 03 A4-03 01 A4-04 7909'-6" 3'-0" 3' - 0 " 4" 1'-5 1/8" 1 1 / 2 " 10 3/4" 10" 6 1 / 8 " 10" 7 5 / 8 " 1 1 / 2 " 10 3/4" 10" 5 3 / 4 " 10" 7 1 / 4 " 1 1 / 2 " 6 1 / 8 " 7 5 / 8 " 10 3/4" 10" 10" 1 1 / 2 " 6 1 / 8 " 7 5 / 8 " 10 3/4" 10" 10" 10 TREADS AT 10" = 8'-4" 3' - 6 " 3' - 6 " 2 TREADS AT 10" = 1'-8" 6 1 / 8 " 3 R I S E R S A T 7 1 / 4 " = 1 ' - 9 3 / 4 " 2 TREADS AT 10" = 1'-8" 7 1 / 4 " 3'-8 3/8" 12 ' - 5 1 / 8 " 7' - 0 " 1 3/4" STEEL HANDRAIL 7921'-6" 7922' MAIN LEVEL 7920'-2 3/8" 7919'-7 7/8" 7906'-6" 7921'-6" D3 A4-04 D4 A4-04 UP 7920'-2 3/8"7919'-7 7/8"7921'-6" 7913'-2 7/8" UP DN02 A4-04 03 A4-03 01 A4-04 STAIRCASE 1 DETAILS A4-04 3 SECTION 3 SCALE: 1/2" = 1'-0" 2 SECTION 2 SCALE: 1/2" = 1'-0" 1 SECTION 1 SCALE: 1/2" = 1'-0" 4 BASEMENT PLAN SCALE: 1/2" = 1'-0" D4 DETAIL 4 SCALE: 1" = 1'-0" 5 MAIN LEVEL PLAN SCALE: 1/2" = 1'-0" D3 DETAIL 3 SCALE: 1" = 1'-0" D2 DETAIL 2 SCALE: 1" = 1'-0" D1 DETAIL 1 SCALE: 1" = 1'-0" GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL 06/22/2020 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 07/29/2020 TF/JH HR HR 08/17/2020 08/17/2020 justinh ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 See updated stair design on next page for winder tread revision at lower landing HR GR SI 2015 IRC Code References GR Guardrails, 36in min high, 4in max opening; required at 30in drop any point w/in 36in horizontally, 2015 IRC R312 HR Handrails 34in-38in high, 2015 IRC R311.7.8 SI Stairway illumination, 2015 IRC R303.7 01/04/2022 justinh 9 TREADS AT 10 1/2" = 7'-10 1/2" 10 R I S E R S A T 7 3 / 1 6 " = 6 ' - 0 " 6 TREADS AT 10 1/2" = 5'-3" 7 R I S E R S A T 6 7 / 8 " = 4 ' - 0 " 4'-6 7/8" 3' - 6 " 3' - 6 " 3' - 6 " 3' - 6 " 6' - 4 " 9' - 0 " 1' - 0 " 3' - 6 " 8' - 0 " 2' - 0 " 7' - 2 3 / 8 " 7922' MAIN LEVEL 7928' MEZZANINE LEVEL 7932' SECOND LEVEL 7937' ATTIC LEVEL D1 A4-06 DN 6 TREA D S A T 1 0 1 / 2 " = 5 ' - 3 " 9 TREADS AT 10 1/2" = 7'-10 1/2"4'-3 5/8"10 1/2" 7928' MEZZANINE LEVEL 7932' SECOND LEVEL 3' - 1 1 1 / 8 " 3 ' - 9 7 / 8 " 01 A4-06 01A4-06 02 A4-06 D3 A4-06 UP 4'-0" 7922' MAIN LEVEL 7928' MEZZANINE LEVEL 01 A4-06 02 A4-06 9 TREADS AT 10 1/2" = 7'-10 1/2" 8' - 0 " 8' - 0 " 1' - 0 " 3' - 6 " 10 R I S E R S A T 7 3 / 1 6 " = 6 ' - 0 " 101 3' - 6 " 9' - 0 " 7932' SECOND LEVEL 7928' MEZZANINE LEVEL 7922' MAIN LEVEL 7937' ATTIC LEVEL 3' - 0 " 210 D2 A4-05 8 R I S E R S A T 7 1 / 2 " = 5 ' - 0 " 7 TREADS AT 10" = 5'-10" 8' - 0 " 1' - 0 " 5' - 1 0 3 / 8 " 7937' ATTIC LEVEL 7928' MEZZANINE LEVEL 7932' SECOND LEVEL D2 A4-06 3' - 6 " 3' - 6 " 3' - 0 " 2'-6 7/8" DN7937' ATTIC LEVEL 7932' SECOND LEVEL 7 TREADS AT 10" = 5'-10" 3' - 3 7 / 8 " 03 A4-06 04 A4-06 3'-6" 7937' ATTIC LEVEL 7932' SECOND LEVEL 3' - 0 " 3' - 6 " D2 A4-05 1 1 / 2 " 10 3/4" 10" 6" 10" 7 1 / 2 " 1 1 / 2 " 11 1/4" 10 1/2" 5 3 / 4 " 10 1/2" 7 1 / 4 " 5/8"1"5/8"WOOD PANELING 3/4" STEEL SHEET 5/8"WOOD PANELING 5/8"1'-8 5/8" R2" R 2 " 3' - 6 " 1' - 0 " 4' - 6 " STAIRCASES 3-4 DETAILS A4-06 D2 DETAIL 2 SCALE: 1" = 1'-0" D1 DETAIL 1 SCALE: 1" = 1'-0" 1 MAIN FLOOR PLAN SCALE: 1/2" = 1'-0" 2 SECOND FLOOR PLAN SCALE: 1/2" = 1'-0" 3 SECTION 1 SCALE: 1/2" = 1'-0"4 SECTION 2 SCALE: 1/2" = 1'-0" 5 SECTION 3 SCALE: 1/2" = 1'-0"6 SECTION 4 SCALE: 1/2" = 1'-0"7 ATTIC PLAN SCALE: 1/2" = 1'-0" GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL D3 DETAIL 3 SCALE: 1" = 1'-0" 06/22/2020 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 07/29/2020 TF/JH HR HR GR GR 10 R I S E R S A T 7 5 / 8 " = 6 ' - 4 1 / 4 " 9 TREADS AT 10" = 7'-6" 3' - 6 " 3 R I S E R S A T 7 5 / 8 " = 1 ' - 1 0 7 / 8 " 3' - 0 " 3' - 6 " 3' - 6 " 1 3/4" STEEL HANDRAIL 3' - 6 " 7919'-7 7/8" 7921'-6" 7913'-2 7/8" D2 A4-04 7909'-6" 3'-0"1'-5 1/8"3'-0" 3' - 0 " 7909'-6" 3'-0" 3' - 0 " 4" 1'-5 1/8" 1' - 0 " 1' - 0 " 1' - 0 " 1' - 0 " 1' - 0 " 3'-0" 4' - 2 " 4' - 2 " 2' - 6 " 15 ' - 6 " 11 ' - 0 " 7909'-6" 7906'-6" 3' - 0 " 7921'-6" 4" WINDOW WELL DETAILS A4-07 2 SECTION 2 SCALE: 1/2" = 1'-0" 3 WINDOW WELL PLAN SCALE: 1/2" = 1'-0" GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL 1 SECTION 1 SCALE: 1/2" = 1'-0" 06/22/2020 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 07/29/2020 TF/JH 002001 5'-5 3/16" 2' - 8 " 2' - 8 " 3'-2 1/2" 103 6' - 0 " 2'-6 7/16" 8 3/4" 4" 5' - 8 " 3' - 0 " 2'-6" 4"1'-3 9/16"4"1'-3 9/16"4" 2'-6" 9'-2 11/16" 101 2' - 4 " 102 6' - 8 " 6 3/4" 8'-7 1/8" 8'-10 11/16" 1' - 8 " 5' - 4 " 2'-2 7/16" 003 3' - 1 0 " 2' - 4 " 2'-10 1/2" 4" 3' - 1 0 " 4' - 2 " 4' - 2 " 2'-5 5/8"2'-5 5/8" 2' - 4 " 9' - 0 " 8' - 4 " 104 105 106 10 ' - 1 3 / 4 " 3'-11 13/16" 4" 3'-10 7/16" 4" 3'-10 7/16" 4" 4'-0 7/16"8" 9' - 5 3 / 4 " 10 ' - 1 3 / 4 " 9' - 5 3 / 4 " 4'-2" 4" 3'-8" 4" 4'-1 5/8" 8 3/8" 4' - 0 " 3' - 0 " 8 1/8"2" 1'-11 3/8" 2" 2'-2" 2" 2'-2" 2" 4" 3' - 8 " 8" 17'-9 1/8"14'-0" 6'-11 3/8" 107 108 4" 3' - 8 " 4' - 0 " 2" 2'-10" 2" 2'-10" 2" 2'-10" 2" 2'-10" 2" 2'-10" 2" 2'-10" 2" 2'-10" 2" 2'-11"2'-11" 2" 2'-10" 2" 2'-10" 2" 2'-10" 2" 2'-10" 2" 2'-10" 2" 2'-10" 2" 2'-10" 2" 2'-10" 2" 2'-10" 2" 24'-1"30'-1" WINDOW SCHEDULE A5-01 WINDOW SCHEDULE Window No. 001 Rough Opening (WxH) 5' 5-3/16" x 2' 8" Material WD Frame Depth --" Finish Int Ext CLR SEE ELEVS Details Notes CLR WD CLRCLR WD CLRCLR WD CLRCLR WD CLRCLR WD CLRCLR WD CLRCLR WD CLRCLR WD CLRCLR --" EgressGlass Type Room No. 009 Window Dimension (WxH) WD --"CLRCLR015 II II II II II II II II II II 002 101 102 103 104 3' 2-1/2" x 2' 8" 8' 7-1/8" x 9' 0" 9' 2-11/16" x 2' 4" 2' 6-7/16" x 6' 0" 17' 9-1/8" x 10' 1-3/4" 14' 0" x 10' 1-3/4" 6' 11-3/8" x 4' 0" 23' 0" x 4' 0" 29' 3-1/2" x 4' 0" 5' 1-3/16" x 2' 4" 2' 10-1/2" x 2' 4" 8' 10-11/16" x 1' 8" 2' 2-7/16" x 5' 4" - 105 106 107 108 GLASS TYPES: I CLEAR, INSULATED II CLEAR, INSULATED, TEMPERED --" --" --" --" --" --" --" 1WINDOW SCHEDULE SCALE: NTS 105 108 109 113 113 114 003 003 003 3'-2 1/2"x8'-4"015 2' 10-1/2" x 7' 10" 2WINDOW TYPES SCALE: 1/2"=1'-0" - - - - - GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL Anderson E-Series U value .26 Anderson E-Series U value .26 Anderson E-Series U value .26 Anderson E-Series U value .26 Anderson E-Series U value .26 Anderson E-Series U value .26 Anderson E-Series U value .26 Anderson E-Series U value .26 Anderson E-Series U value .26 Anderson E-Series U value .26 Anderson E-Series U value .26 06/22/2020 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 All windows and exterior doors to be NFRC labeled at inspection. 07/29/2020 TF/JH 201 8' - 4 " 3' - 0 " 3'-4" 4'-0" 4" 4" 7' - 4 " 203 202 4' - 0 " 9'-4 11/16" 9'-0 11/16" 7 5/16" 6" 3' - 4 " 16 ' - 6 " 12'-10 3/4"8'-4 1/2" 4" 3'-10 1/4" 4" 3'-10 1/4" 4" 3'-10 1/4" 4" 3'-10 1/4" 4" 3'-10 1/4" 4" 9' - 2 1 5 / 1 6 " 4" 4" 5' - 8 1 / 1 6 " 4" 4" 3" 20'-11 1/4" 8'-7 1/8" 10 ' - 4 1 / 2 " 9' - 1 0 1 / 2 " 2'-2"8" 11 9/16" 8" 11 9/16" 8"2'-2" 4' - 0 " 204 209207208207 205 3' - 0 " 4' - 0 " 10'-8" 10'-4" 3' - 4 " 6" 10 ' - 4 " 2' - 4 " 2' - 4 " 10 ' - 4 " 4'-10 1/16" 4'-2 1/16" 9' - 4 " 8" 2' - 4 " 10 ' - 4 " 4'-10 1/16" 4'-2 1/16" 9' - 4 " 8" 7' - 8 " 3'-4 9/16" 2'-8 9/16" 6' - 8 " 4" 4" 1' - 6 " 6' - 3 9 / 1 6 " 7'-7 5/8" 7'-3 5/8" 1' - 2 " 9'-0 1/16" 8'-4 1/16" 9' - 4 " 8" 206 4' - 8 " 2' - 4 " 2'-0" 1'-8" 4' - 0 " 6" 4'-6 1/16" 4'-2 1/16"4'-2 1/16" 4'-6 1/16" 210 301 WINDOW SCHEDULE A5-023WINDOW TYPES SCALE: 1/2"=1'-0" WD CLRCLR WD CLRCLR II II 4' 0" x 8' 4" 8' 7-1/8" x 10' 4-1/2" 3' 4" x 7' 4"201 202 --" --" 203 9' 4-11/16" x 4' 0"WD --"CLRCLR WD CLRCLR WD CLRCLR WD CLRCLR WD CLRCLR WD CLRCLR WD CLRCLR --" WD --"CLRCLR II II II II II II II II 204 205 206 207 208 18' 0" x 14' 3-1/4" 10' 8" x 4' 0" 9' 0-1/16" x 10' 4" 4' 10-1/16" x 10'4" 4' 10-1/16" x 10'4" 3' 4-9/16" x 7' 8" 7' 7-5/8" x 1' 8" 9' 0-11/16" x 3' 4" 10' 4" x 3' 4" 8' 4-1/16" x 9' 4" 4' 2-1/16" x 9' 4" 2' 8-9/16" x 6' 8" 7' 3-5/8" x 1' 2" 209 301 --" --" --" --" --" 201 202 203 222 219 216 212 208 207 301 210 216 2' 0" x 4' 8"1' 8" x 4' 0"WD CLRCLR--"II 4' 2-1/16" x 9' 4" - - WINDOW SCHEDULE Window No. Rough Opening (WxH)Material Frame Depth Finish Int Ext SEE ELEVS Details NotesEgressGlass Type Room No. Window Dimension (WxH) GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL Anderson E-Series U value .26 Anderson E-Series U value .26 Anderson E-Series U value .26 Anderson E-Series U value .26 Anderson E-Series U value .26 Anderson E-Series U value .26 Anderson E-Series U value .26 Anderson E-Series U value .26 Anderson E-Series U value .26 Anderson E-Series U value .26 Anderson E-Series U value .26 06/22/2020 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 All windows and exterior doors to be NFRC labeled at inspection. 07/29/2020 TF/JH A 8' - 0 " 4'-0" B 7' - 0 " 2'-8" C 7' - 0 " 3'-0" HE 7' - 0 " 3'-0" F 7' - 0 " 2'-9 5/16" 10'-0"15'-0" G 10 ' - 4 " 1'-8" 2'-6" D 7' - 0 " 2'-6" 9' - 0 " 11 ' - 0 " 18'-0" KI 9' - 6 " 9' - 6 " J 10'-0"15'-0" DOOR SCHEDULE A5-03 1DOOR SCHEDULE SCALE: NTS DOOR SCHEDULE Room Name#Opening (WxHxTH)Type Material Finish Door Frame Material Finish Head Jamb No. Details Hrdwr Notes 001 B PNT WD 002 005 PDR 002 2'-8"x7'-0"x1-3/4" 003 004 WD PNT -PNT Trim - Threshold -- 2DOOR TYPES SCALE: 1/2"=1'-0" 006 007 010 008 009 011 012 -PNT WDMEDIA ROOM 001 15'-2"x13'-6"x1 3/4"WD PNT -PNT--- I PNT WDSPORTS COURT 003 10'-0"x9'-6"x1-3/4"WD PNT -PNT--- B PNT WDCORRIDOR 006 2'-8"x7'-0"x1-3/4"WD PNT -PNT--- B PNT WDLAUNDRY ROOM 005 2'-8"x7'-0"x1-3/4"WD PNT -PNT--- B PNT WDUTILITY ROOM 017 2'-8"x7'-0"x1-3/4"WD PNT -PNT--- B PNT WDMECHANICAL RM 012 2'-8"x7'-0"x1-3/4"WD PNT -PNT--- B PNT WD2'-8"x7'-0"x1-3/4"WD PNT -PNT--- B PNT WDGUEST BEDROOM 015 2'-8"x7'-0"x1-3/4"WD PNT -PNT--- B PNT WDGUEST BATH 016 2'-8"x7'-0"x1-3/4"WD PNT -PNT--- B PNT WDSTAIR 014 2'-8"x7'-0"x1-3/4"WD PNT -PNT--- B PNT WDSTAIR 014 2'-8"x7'-0"x1-3/4"WD PNT -PNT--- MECHANICAL RM 012 013 014 B PNT WDCORRIDOR 010 2'-8"x7'-0"x1-3/4"WD PNT -PNT--- J PNT WDWD PNT -PNT---SPORTS COURT 003 101 A ----MTL4'-0"x8'-0"x2"GLS -----MTL---CORRIDOR 104 EXTERIOR 102 C PNT WDWD PNT -PNT---PACKAGE ROOM 101 103 C PNT WDWD PNT -PNT--- 104 G PNT WDWD PNT -PNT--- 105 B PNT WDWD PNT -PNT--- 106 D PNT WDWD PNT -PNT--- 107 B PNT WDWD PNT -PNT--- 108 B PNT WDWD PNT -PNT--- 109 B PNT WDWD PNT -PNT--- 110 E PNT WDWD PNT -PNT--- 111 B PNT WDWD PNT -PNT--- 112 B PNT WDWD PNT -PNT--- 113 B PNT WDWD PNT -PNT--- 114 K PNT WDWD PNT -PNT--- EXTERIOR 3'-0"x7'-0"x1-3/4" CORRIDOR 102 3'-0"x7'-0"x1-3/4" CORRIDOR 102 2'-6"x9'-0"x1-3/4" PDR ROOM 107 2'-8"x7'-0"x1-3/4" TOILET 109 2'-6"x7'-0"x1-3/4" CORRIDOR 110 2'-8"x7'-0"x1-3/4" CORRIDOR 110 2'-8"x7'-0"x1-3/4" MUDROOM 114 2'-8"x7'-0"x1-3/4" LAUNDRY ROOM 115 3'-0"x7'-0"x1-3/4" MUDROOM 114 2'-8"x7'-0"x1-3/4" MUDROOM 114 2'-8"x7'-0"x1-3/4" GARAGE 116 2'-8"x7'-0"x1-3/4" GARAGE 115 201 202 203 204 205 206 207 DECK 224 CORRIDOR 210 BATHROOM 1 209 CORRIDOR 214 BATHROOM 2 213 -CORRIDOR 217 BATHROOM 3 219 2'-9 5/16"x7'-0"x1-3/4" 2'-8"x7'-0"x1-3/4" 2'-6"x7'-0"x1-3/4" 2'-8"x7'-0"x1-3/4" 2'-6"x7'-0"x1-3/4" 2'-8"x7'-0"x1-3/4" 2'-8"x7'-0"x1-3/4" F ----MTLGLS -----MTL--- B PNT WDWD PNT -PNT--- D PNT WDWD PNT -PNT--- B PNT WDWD PNT -PNT--- D PNT WDWD PNT -PNT--- B PNT WDWD PNT -PNT--- B PNT WDWD PNT -PNT--- EXTERIOR EXTERIOR EXTERIOR EXTERIOR 18'-0"x11'-0"x3" EXTERIOR EXTERIOR 15'-0"x9'-6"x1-3/4" 208 BEDROOM 2 212 1'-8"x10'-4"x8-3/8"H PNT WDWD PNT -----EXTERIOR 209 BEDROOM 1 208 1'-8"x10'-4"x8-3/8"H PNT WDWD PNT -----EXTERIOR GENERAL CONTRACTOR Janckila Construction Inc. 75 Buckskin Drive Carbondale, CO 81623 T 970.963.7239 F 970.963.7239 STRUCTURAL ENGINEER Albright and Associates 402 Park Ave., Unit A Basalt, CO 81621 T 970.927.4363 CIVIL ENGINEER Roaring Fork Engineering 592 Highway 133, Carbondale, CO 81623 T 970.948.7474 MEP ENGINEER Bighorn Consulting Enginners, Inc. 386 Indian Road Grand Junction, CO 81501 T 970.241.8709 LANDSCAPE ARCHITECT Richard Camp Landscape Architecture P.O. Box 958 Carbondale, CO 81623 T 970.963.7123 IRRIGATION DESIGNER Hines Inc. 323 West Drake Road #204 Fort Collins, CO 80526 T 970.233.7925 ACOUSTIC CONSULTANT Acentech 33 Moulton Street Cambridge, MA 02138 T 617.499.8000 F 617.499.8074 61 7 W E S T B L E E K E R S T R E E T AS P E N AS P E N , C O 8 1 6 1 1 Drawing Title: Drawing No: Phase: Architect 29 Stanhope Street 3rd Floor Boston, MA 02116 T 617.426.0995 F 617.426.0998 MONICA PONCE DE LEON STUDIO, INC. DATE & ISSUE DESCRIPTION BY CHECK ISSUE/ REVISION Project Number: 1803 PERMIT SET RE S I D E N C E 05/03/2019 RDS SET AK MPdL1 2 09/24/2019 PERMIT SET AK MPdL 3 04/07/2020 PERMIT SET AK/RK MPdL 06/22/2020 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 07/30/2020 All windows and exterior doors to be NFRC labeled at inspection. Openings between the garage and residence shall be equipped with solid wood doors not less than 1 3/8 inches (35 mm) in thickness, solid or honeycomb core steel doors not less than 1 3/8 inches (35 mm) thick, or 20-minute fire-rated doors, equipped with a self-closing device (IRC 302.5.1) 07/29/2020 TF/JH