Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.691 Pfister Dr.0023-2024-BROF (2)
ESICC Most Widely Accepted and Trusted Evl;� ual SERVICE�r P� Mccaor no.wen (i Innovation ICC-ES Evaluation Report ESR-2119 ICC-ES I (800) 423-6587 I (562) 699-0543 I www.icc-es.org Reissued 08/2017 This report is subject to renewal 08/2019. DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION SECTION: 07 31 33—COMPOSITE RUBBER SHAKES REPORT HOLDER: DAVINCI ROOFSCAPES, LLC 13890 WEST 101sT STREET LENEXA, KANSAS 66215 EVALUATION SUBJECT: DAVINCI SLATE, DAVINCI SHAKE, BELLAFORTE SHAKE AND BELLAFORTE SLATE ROOF SHINGLES �i ICC ICC c� LEs- iCC PMG c LISTED Look for the trusted marks of Conformity! 111111 "2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC)Award in Excellence" A Subsidiary of cam comic ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes no specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a (ANSI recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as `°"' 31'1I ISOMC nose to any finding or other matter in this report, or as to any product covered by the report. Product cauq.a eoe► Ammaca. aePEN BUILDING DEPARTMENT Copyright© 2018 ICC Evaluation Service, LLC. All rights reserved. ESE'i�LU�TdjN SERVICE �-,,,,� Most Widely Accepted and Trusted •ICC-ES Evaluation Report ESR-2119 Reissued August 2017 Revised December 2017 This report is subject to renewal August 2019. www.icc-es.org I (800)423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE slate or shake, respectively. The shingles are PROTECTION manufactured with a proprietary formulation using both Section: 07 31 33—Composite Rubber Shakes high-density and low-density polyethylene polymers and other additives. REPORT HOLDER: The attributes of the roof tiles have been verified as DaVINCI ROOFSCAPES, LLC conforming to the provisions of CALGreen Section A5.406.1.2 for reduced maintenance. Note that decisions 13890 WEST 101ST STREET LENEXA, KANSAS 66215 on compliance for those areas rest with the user of this (913)599-0766 report. The user is advised of the project-specific www.davinciroofscapes.com provisions that may be contingent upon meeting specific conditions, and the verification of those conditions is EVALUATION SUBJECT: outside the scope of this report. These codes or standards often provide supplemental information as guidance. DaVINCI SLATE, DaVINCI SHAKE, BELLAFORTE 3.2 DaVinci Slate Roof Shingle: SHAKE,AND BELLAFORTE SLATE ROOF SHINGLES The DaVinci Slate roof shingle is available in various colors 1.0 EVALUATION SCOPE and in widths of 6, 7, 9, 10 and 12 inches (152, 178, 229, 254 and 305 mm) with a length of 18 inches (457 mm). 1.1 Compliance with the following codes: Exposure is 6 to 8 inches (152 to 203 mm), resulting in an • 2015, 2012, 2009 and 2006 International Building installed weight of 351 to 264 pounds, respectively, per Code°(IBC) 100 square feet (17.1 to 12.9 kg/m ). See Figure 1 [10- inch-and 12-inch-wide (254 and 305 mm)shingles shown] • 2015, 2012, 2009 and 2006 International Residential for further details. Code°(IRC) • 2013 Abu Dhabi International Building Code(ADIBC)t 3.3 DaVinci Shake Roof Shingle: tThe ADIBC is based on the 2009 IBC.2009 IBC code sections referenced The DaVinci Shake roof shingle is available in various in this report are the same sections in the ADIBC. colors and in widths of 4, 6, 7, 8 and 9 inches (102, 152, Properties evaluated: 178, 203 and 229 mm) with a length of 22 inches (559 mm). Exposure is 9 to 10 inches (229 to 254 mm), • Weather resistance resulting in an installed weight of 377 to 300 pounds, • Fire classification respectively, per 100 square feet(18.4 to 14.6 kg/m2). See • Wind resistance Figure 1 [9-inch-wide (229 mm) shingle shown] for further details. 1.2 Evaluation to the following green code: 3.4 Bellaforte Shake: • 2016 California Green Building Standards Code (CALGreen), Title 24, Part 11 The Bellaforte Shake roof shingle is available in various colors and in a width of 12 /4 inches(324 mm)and a length Attributes verified: of 161/4 inches(413 mm). Exposure is 12 inches(305 mm), • See Section 3.1 resulting in an installed weight of 194 pounds per 100 2.0 USES square feet(9.5 kg/m2). See Figure 2 for further details. The DaVinci Slate, DaVinci Shake, Bellaforte Shake, and 3.5 Bellaforte Slate: Bellaforte Slate roof shingles are used as roof covering The Bellaforte Slate roof shingle is available in various materials and are recognized as a Class A roof covering colors and in a width of 123/4 inches (324mm)and a length when installed in accordance with this report. of 151/2 inches(394 mm). Exposure is 12 inches(305 mm), 3.0 DESCRIPTION resulting in an installed weight of 162 pounds per 100 3.1 General: square feet(8.0 kg/m2). See Figure 2 for further details. The DaVinci Slate, DaVinci Shake, Bellaforte Shake, and 3.6 Underlayment: Bellaforte Slate roof shingles are engineered polymeric- 3.7 Underlayment must be a minimu- e based roof shingles designed to provide the look of natural ASTM D226 Type I (No. 15) asphalt-sa*. -i o I t ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construe 024 as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as to any finding or other matter in this report,or as to any product covered by the report. oFRIZcii� -- n Copyright©2018 ICC Evaluation Service,LLC.All rights reserved. AP`d kl l5f 4 BUILDING DEPARTMENT ESR-2119 I Most Widely Accepted and Trusted Page 2 of 7 or one layer of Type II (No. 30) asphalt-saturated organic maximum gap of 3/8 inch (9.5 mm) is recommended felt, complying with ASTM D226, unless otherwise noted in between shingles, with a minimum 1/4-inch (6.4 mm) gap Table 1 of this report. required. The gaps between shakes at adjacent courses 3.8 Flashing: must be offset a minimum of 11/2 inches (38 mm). The maximum allowable exposure is 8 inches (203 mm) for Flashing must be minimum 16-oz/ft2 (No. 23 gage) copper DaVinci Slate roof shingles, and 10 inches (254 mm) for or other corrosion-resistant metal with a thickness of not DaVinci Shake roof shingles. less than 0.019 inch (0.483 mm). See Section 4.5 for valley flashing. 3.12.2 Bellaforte Shake and Bellaforte Slate Roof Shingles: Bellaforte Shake or Bellaforte Slate (12 3/4 3.9 Fasteners: inches wide [324 mm]) must be installed on top of starter Fasteners used to secure DaVinci roof shingles to the tiles and must extend approximately 1 inch (25.4 mm)over sheathing must bet/8-inch-diameter-shank (3.18 mm) hot- the eaves. The shingles are secured to the sheathing using dipped galvanized roofing nails complying with ASTM three fasteners, two through the premolded nail markers F1667,with 3/8-inch-diameter(9.5 mm)heads. The DaVinci and one through the tab; or five fasteners, four through the Shake roofing may be secured with 1/8-inch-diameter- premolded nail markers and one through the tab. shank (3.18 mm) stainless steel nails complying with Fasteners are as described in Section 3.9. See Table 2 for ASTM F1667, with 3/8-inch-diameter (9.5 mm heads). additional fastening details. Fasteners must be of sufficient length to penetrate through The field shingles must be installed flush with the starter the sheathing a minimum of 1/2inch (12.7 mm). slate or shake shingles on the lower edges. INSTALLATION 3.10 General: 3.13 Hips and Ridges: General: The top of hips and ridges must be covered The roof shingles must be installed in accordance with this with a minimum 6-inch-wide (152 mm)flashing as noted in report, the applicable code and the manufacturer's Section 3.7. Flashing must be attached to the sheathing published installation instructions. The manufacturer's installation instructions must be available at the jobsite at using No. 12 gage, ring-shank, corrosion-resistant nails. all times during insto on. Nails must be compatible with the flashing materal, and have sufficient length to penetrate the sheathing 3/4 inch The shingles must be installed on roofs with solid (19 mm)or through the sheathing,whichever is less. sheathing and a minimum slope of 3:12 (25 percent slope). Solid sheathing must be minimum 15/32-inch 3.13.1 DaVinci Slate Roof Shingles: On top of the thick (11.9 mm) exterior-grade plywood, 7/18-inch-thick flashing, 76 inch wide (1930 mm) or 7-inch-wide (11.1 mm) oriented strand board (OSB), or nominally (178 mm) DaVinci Slate roof shingles are installed on each 1-inch-thick (25.4 mm) lumber. The sheathing must be side of hips and ridges, with the shingles butting at the top. structurally adequate and fastened to resist the wind loads Both hip and ridge shingles must be installed with a 6-inch as specified by IBC Section 1609, or IRC Section R301.2, (152 mm) exposure. Shingles must be secured with the for components and cladding. fasteners described in Section 3.9. 3.11 Underlayment: 3.13.2 DaVinci Shake Roof Shingles: On top of the flashing, 6-inch-wide (152 mm) DaVinci Shake roof Underlayment as described in Section 3.6 and Table 1, shingles are installed on each side of hips and ridges, with must be installed in accordance with IBC Section 1507.7.3 the shingles butting at the top. Both hip and ridge shingles or IRC Section R905.6.3, as applicable. The underlayment must be installed with a 10-inch (254 mm) exposure. must be installed parallel to the roof eave with a 6-inch Shingles must be secured with the fasteners described in (152 mm) lap on the ends, a 6-inch (152.4 mm) side lap Section 3.9. and a minimum 6-inch (152 mm) lap over eaves. The underlayment is fastened, only as necessary to hold in 3.13.3 Bellaforte Shake: Bellaforte Shake one-piece hip place. and ridge tiles are installed at a 12-inch (305 mm) exposure. The tiles are nailed once on each side In areas where the average daily temperature in January approximately 3/4 inch (19 mm) from the outside edge and is 25°F (-4°C) or less, or where there is a possibility of ice 121/2 inches (305 mm) from the butt of the tile. Shingles forming along the eaves and causing a backup of water, an must be secured with the fasteners described in Section ice barrier that consists of at least two layers of 3.9. underlayment cemented together, or a self-adhering underlayment complying with ASTM D1970 or currently 3.13.4 Bellaforte Slate: Bellaforte Slate one piece hip and recognized in an ICC-ES evaluation report as complying ridge tiles are installed at a 12-inch (305 mm) exposure. with the ICC-ES Acceptance Criteria for Self-adhered The tiles are nailed once on each side approximately 3/4 Underlayments for Use as Ice Barriers (AC48), must inches (19 mm) from the outside edge and 121/2 inches extend from the eave's edge to a point 24 inches(610 mm) (318 mm) from the butt of the tile. Shingles must be inside the exterior wall line of the building. secured with the fasteners described in Section 3.9. 3.12 Roof Shingles: 3.14 Valleys: 3.12.1 DaVinci Slate and DaVinci Shake Roof Shingles: Valleys must be flashed in accordance with 2015, 2012 Starting with a row of 12-inch-wide (305 mm) DaVinci and 2009 IBC Section 1507.7.7 [2006 IBC Section Starter Slates or Shakes, the shingles must extend 1507.7.6] or IRC Section R905.6.6 , as a plicable n t approximately 1 inch (25.4 mm)over the eaves and 3/4 inch manufacturer's published installation in 1\L.CR.. • Lam(19 mm) over the rakes. The shingles are secured to the flashing described in Section 3.8. 1 ���� LLLL���. sheathing using two fasteners, driven through the premolded nail markers. Fasteners are as described in 3.15 Fire Classification: 0 4/19/2 0 2 4 Section 3.9. See Table 2 for additional fastening details. The DaVinci roof shingles comply with IBC Section 1505.2 The field shingles must be installed flush with the starter and IRC Section R902.1 as a Class A roof covlgswi lyn slate or shake shingles on the outer and lower edges. A installed as described in Table 1. BUILDING DEPARTMENT ESR-2119 I Most Widely Accepted and Trusted Page 3 of 7 3.16 Wind Resistance: specified in, those codes listed in Section 1.0 of this report, The allowable wind uplift pressures for the DaVinci roof subject to the following conditions: shingles described in this report are as noted in Table 2. 4.1 Installation must comply with the applicable code, the The roof shingles have maximum design wind speeds at manufacturer's published installation instructions and corresponding maximum roof heights as shown in Tables 3 this report. In the event of a conflict between this and 4. report and the manufacturer's published installation 3.17 Reroofing: instructions, this report governs. Prior to application of the shingles, the existing roof 4.2 The roof shingles are manufactured in Lenexa, covering and underlayment must be completely removed. Kansas, under a quality control program with inspections by ICC-ES. Any damaged sheathing must be replaced. The installation of the shingles must then proceed as described in 5.0 EVIDENCE SUBMITTED Sections 4.1 through 4.5. An existing self-adhered ice Data in accordance with the ICC-ES Acceptance Criteria barrier membrane may remain in place if covered with a for Special Roofing Systems (AC07), dated February 2014 new ice barrier membrane in accordance with the (editorially revised May 2016). applicable code. The roof classification is as noted in Section 4.6 and Table 1. 6.0 IDENTIFICATION 4.0 CONDITIONS OF USE Each roof shingle is labeled with the report holder's name(DaVinci Roofscapes, LLC)and address,the product The DaVinci Slate, DaVinci Shake, Bellaforte Shake, and name, the shingle width, a production date code, and the Bellaforte Slate roof shingles described in this report ICC-ES evaluation report number(ESR-2119). comply with, or are suitable alternatives to what is TABLE 1—FIRE CLASSIFICATIONS SYSTEM ROOF ROOF MIN. DaVINCI ROOF SHINGLE NO. CLASS DECK SLOPE UNDERLAYMENT Roof Shingle Exposure(in.) One layer ASTM D226 Type II (No.30)or two layers Min. 15/3z of ASTM D Type I (No. 15)asphalt-saturated organic 1 A 3:12 felt may be used;or DaVinci Slate 6 plywood Iyw ood One layer GAF Versashield®Fire-Resistant Roof Deck Protection(ESR-2053) 2 A Min. 15/32- 3:12 One layer GAF Versashield®Fire-Resistant Roof DaVinci Slate 6 to 71/2 inch plywood Deck Protection(ESR-2053) DaVinci Shake 9 to 10 Min. 15/32 One layer ASTM D226 Type II (No.30)asphalt- DaVinci Slate 6 to 8 3 A inch plywood 3:12 saturated organic felt plus one layer of ASTM D3909 DaVinci Shake 9 to 10 mineral-surfaced cap sheet Bellaforte Shake 12 DaVinci Slate 6 to 8 4 A Min. 15/32- 3:12 Two layers ASTM D226 Type II (No.30)asphalt- DaVinci Shake 9 to 10 inch plywood coated glass-fiber-mat Bellaforte Shake 12 Bellaforte Slate 12 DaVinci Slate 6 to 8 Min. 15/32- One layer Eco Chief Products SolarHideTM-SRW DaVinci Shake 9 to 10 5 A inch plywood 3.12 (ESR-4035) Bellaforte Shake 12 Bellaforte Slate 12 For SI: 1-inch=25.4 mm; ift=0.305m 1 ASTM D226 Type I (No. 15)and Type II (No. 30) underlayment must be installed in accordance with the applicable building code. GAF Versashield® Fire-Resistant Roof Deck Protection underlayment must be installed in accordance with ESR-2053. Eco Chief Products SolarHideTM-SRW underlayment must be installed in accordance with ESR-4035. RECEIVED 04/19/2024 ASPEN BUILDING DEPARTMENT ESR-2119 I Most Widely Accepted and Trusted Page 4 of 7 TABLE 2—ALLOWABLE WIND UPLIFT PRESSURE VALUES DaVINCI ROOF SHINGLE ALLOWABLE SYSTEM UPLIFT NO. ROOF DECK Roofing Exposure Shingle Fastening PRESSURE Shingle (inches) (psf) Min.15/32-inch Min.two 13/4-inch long by 1/8-inch diameter shank hot- 1 plywood DaVinci Slate 6 dipped roofing nails with 3/8-inch nominal diameter 75 heads into premolded nail markers,per shingle Min.two 11/2-inch long by 1/8-inch-diameter shank Min.15/32-inch hot-dipped galvanized roofing nails with 3/8-inch- 2DaVinci Slate 8 60 plywood nominal-diameter heads into premolded nail markers, per shingle Min.two 13/4-inch long by 1/8-inch diameter shank Min.15/32-inch hot-dipped or stainless steel roofing nails with 3 plywood DaVinci Shake 10 3/8-inch nominal diameter heads into premolded nail 75 markers, per shingle Min.three 13/4-inch long by 1/8-inch diameter shank 4 Min. 15/32-inch Bellaforte Slate 12 hot-dipped roofing nails with 3/8-inch nominal 45 plywood Bellaforte Shake diameter heads,two through premolded nail markers and one through the tab,per shingle Min.15/32-inch Min.five 13/4-inch long by 1/8-inch diameter shank hot- 5 plywood Bellaforte Shake 12 dipped roofing nails with /8-inch nominal diameter 75 heads into premolded nail markers per,shingle For SI: 1-inch=25.4 mm; 1 ft=0.305 m; 1 psf=47.88 Pa RECEIVED 04/19/2024 ASPEN BUILDING DEPARTMENT ESR-2119 I Most Widely Accepted and Trusted Page 5 of 7 TABLE 3-2015 and 2012 IBC and 2015 IRC WIND SPEED& MAXIMUM MEAN ROOF HEIGHT1'2 Maximum Allowable Mean Roof Heights(ft.)for Gable Roofs (Slope 3:12—6:12) DaVINCI SHINGLES EXPOSURE Ultimate Design Wind Speed Volt(mph) Roofing Shingle Exposure(in.) Min.No. CATEGORY <110 115 120 130 140 150 160 170 180 Fasteners B 60 60 60 60 60 60 49 33 NA DaVinci Slate 6 2 C 60 60 60 60 45 22 NA NA NA DaVinci Shake 10 D 60 60 60 40 19 NA NA NA NA B 60 60 60 60 60 35 NA NA NA DaVinci Slate 8 2 C 60 60 60 30 16 NA NA NA NA D 60 51 31 NA NA NA NA NA NA B 60 60 60 NA NA NA NA NA NA Bellaforte Slate 12 3 C 33 26 17 NA NA NA NA NA NA Bellaforte Shake 12 D 17 NA NA NA NA NA NA NA NA B 60 60 60 60 60 60 49 33 NA Bellaforte Slate 12 5 C 60 60 60 60 45 22 NA NA NA Bellaforte Shake D 60 60 60 40 19 NA NA NA NA Maximum Allowable Mean Roof Heights(ft.)for Gable Roofs (Slope 6.1:12—12:12) DaVINCI SHINGLES EXPOSURE Ultimate Design Wind Speed Vu,t(mph) Roofing Shingle Exposure(in.) Min.No. CATEGORY <110 115 120 130 140 150 160 170 180 Fasteners - B 60 60 60 60 60 60 60 60 60 DaVinci Slate 6 2 C 60 60 60 60 60 60 60 60 60 DaVinci Shake 10 D 60 60 60 60 60 60 60 60 54 B 60 60 60 60 60 60 60 60 60 DaVinci Slate 8 2 C 60 60 60 60 60 60 60 60 37 D 60 60 60 60 60 60 60 31 15 B 60 60 60 NA NA NA NA NA NA Bellaforte Slate 12 3 C 60 60 60 NA NA NA NA NA NA Bellaforte Shake 12 D 60 60 60 NA NA NA NA NA NA B 60 60 60 60 60 60 60 60 60 Bellaforte Slate 12 5 C 60 60 60 60 60 60 60 60 60 Bellaforte Shake 12 D 60 60 60 60 60 60 60 60 NA Maximum Allowable Mean Roof Heights(ft.)for Hip Roofs (Slope 3:12—5.6:12) DaVINCI SHINGLES EXPOSURE Ultimate Design Wind Speed Vim(mph) Roofing Shingle Exposure(in.) Min.No. CATEGORY <110 115 120 130 140 150 160 170 180 Fasteners B 60 60 60 60 60 60 60 60 60 DaVinci Slate 6 2 C 60 60 60 60 60 60 60 45 24 DaVinci Shake 10 - D 60 60 60 60 60 60 30 19 NA B 60 60 60 60 60 60 60 60 38 DaVinci Slate 8 2 C 60 60 60 60 60 52 26 16 NA D 60 60 60 60 50 22 NA NA NA B 60 60 60 NA NA NA NA NA NA Bellaforte Slate 12 3 C 60 60 60 NA NA NA NA NA NA Bellaforte Shake 12 D 60 60 60 NA NA NA NA NA NA B 60 60 60 60 60 60 60 60 60 Bellaforte Slate 12 5 C 60 60 60 60 60 60 60 45 24 Bellaforte Shake 12 D 60 60 60 60 60 60 30 19 NA For SI: 1ft=25.4 m, 1 mph=0.44m/s NA—Not Applicable 'Mean roof heights were determined from maximum allowable wind uplift pressures(see Table 2)and wind loads calculated in accordance with ASCE 7-10 Section 30.5 for enclosed buildings with a topographic factor,Kzt=1.0. 2Pressure area defined per ASCE 7-10, Figure 30.5 in Zone 3,tributary area 10ft2 or less results in maximum pressure. RECEIVED 04/19/2024 ASPEN BUILDING DEPARTMENT ESR-2119 I Most Widely Accepted and Trusted Page 6 of 7 TABLE 4-2009 and 2006 IBC and 2012,2009 and 2006 IRC WIND SPEED &MAXIMUM MEAN ROOF HEIGHT1'2 Maximum Allowable Mean Roof Heights(ft.)for Gable (Slope 3:12—6.1:12) DaVINCI SHINGLES EXPOSURE Basic Wind Speed(mph-3-second gust) Roofing Shingle Exposure(in.) Min.No. CATEGORY 85 90 100 105 110 120 125 130 140 145 150 170 Fasteners B 60 60 60 60 60 60 46 35 NA NA NA NA DaVinci Slate 6 2 C 60 60 60 57 36 16 NA NA NA NA NA NA DaVinci Shake 10 D 60 60 43 25 NA NA NA NA NA NA NA NA B 60 60 60 60 52 NA NA NA NA NA NA NA DaVinci Slate 8 2 C 60 60 31 19 NA NA NA NA NA NA NA NA D 60 41 NA NA NA NA NA NA NA NA NA NA Bellaforte Slate 12 B 60 60 36 NA NA NA NA NA NA NA NA NA Bellaforte Shake 12 3 C 38 22 NA NA NA NA NA NA NA NA_ NA NA D 15 NA NA NA NA NA NA NA NA NA NA NA Bellaforte Slate B 60 60 60 60 60 60 46 35 NA NA NA NA Bellaforte Shake 12 5 C 60 60 60 57 36 16 NA NA NA NA NA NA D 60 60 43 25 NA NA NA NA NA NA NA NA Maximum Allowable Mean Roof Heights(ft.)for Gable (Slope 6.1:12—12:12) DaVINCI SHINGLES EXPOSURE Basic Wind Speed(mph-3-second gust) Roofing Shingle Exposure(in.) FaMin.steners No. CATEGORY 85 90 100 105 110 120 125 130 140 145 150 170 DaVinci Slate 6 B 60 60 60 60 60 60 60 60 60 60 60 60 DaVinci Shake 10 2 C 60 60 60 60 60 60 60 60 60 60 45 16 D 60 60 60 60 60 60 60 60 52 35 23 NA B 60 60 60 60 60 60 60 60 60 60 60 NA DaVinci Slate 8 2 C 60 60 60 60 60 60 60 60 36 26 19 NA D 60 60 60 60 60 60 52 33 _ NA NA NA NA Bellaforte Slate 12 B 60 60 60 60 60 NA NA NA NA NA NA NA Bellaforte Shake 12 3 C 60 60 60 60 60 NA NA NA NA NA NA NA D 60 60 60 60 43 NA NA NA NA NA NA NA Bellaforte Slate B 60 _ 60 60 60 60 60 60 _ 60 60 60 60 60 Bellaforte Shake 12 5 C 60 60 60 60 60 60 60 60 60 60 45 16 D 60 I 60 60 60 60 60 60 I 60 52 35 j 23 NA Maximum Allowable Mean Roof Heights(ft.)for Hip Roofs (Slope 3:12—5.6:12) DaVINCI SHINGLES EXPOSURE Basic Wind Speed(mph-3-second gust) Roofing Shingle Exposure(in.) Min.No. CATEGORY 85 90 100 105 110 120 125 130 140 145 150 170 Fasteners DaVinci Slate 6 B 60 60 60 60 60 60 60 60 60 60 50 NA DaVinci Shake 10 2 C 60 60 60 60 60 60 60 48 24 17 NA NA D 60 60 60 60 60 51 32 20 NA NA NA NA B 60 60 60 60 60 60 60 60 37 30 NA NA DaVinci Slate 8 2 C 60 I 60 I 60 60 60 30 24 17 NA NA NA NA D 60 60 60 60 39 NA NA NA NA NA NA NA Bellaforte Slate 12 B 60 60 60 60 60 NA NA NA NA NA NA NA Bellaforte Shake 12 3 C 60 60 37 32 21 NA NA NA NA NA NA NA D 60 60 21 NA NA NA NA NA NA NA NA NA Bellaforte Slate B 60 60 60 60 60 60 60 60 60 60 50 NA Bellaforte Shake 12 5 C 60 60 60 60 60 60 60 48 23 17 NA NA D 60 60 60 60 60 51 32 20 NA NA NA NA For SI: 1ft=25.4 m, 1mph=0.44m/s NA—Not Applicable 1Mean roof heights were determined from maximum allowable wind uplift pressures(see Table 2)and wind loads calculated in accordance with ASCE 7-05 Section 6.4.2.2 for enclosed buildings with importance factor 1.0 and topographic factor,KZ,=1.0. 2Pressure area defined per ASCE 7-05, Figure 6-2 in Zone 3,tributary area 10ft2 or less results in maximum pressure. RECEIVE 04/19/2024 ASPEN BUILDING DEPARTMENT ESR-2119 I Most Widely Accepted and Trusted Page 7 of 7 10" DaVINCI SLATE 12" DaVINCI SLATE 9" DaVINCI SHAKE ....., , pr±uurH0-4,"-";) . -t. .,KT •-. fl' C. lC) i__ Er) � cs) OQO ,- 1 iict c., ij1'! ,0 , . 4 1 • 4,) 'VI , �' , I. r ILJ4 . ' 4/ 4 $1 r,e) , i si 1 ;• it 11 I 10.00" 1 12.00" 9.0" j I (+/— 0.0625") I (+/— 0.0625")l 1_(+/— 0.625") DaVINCI SLATE SIDE VIEW r 0.500" (+/-0.031") I 0.125" (+/-0.020") DaVINCI SHAKE SIDE VIEW i (+/-0.031") I T 0.125" 0.253" (+/0.020")For SI: 1 inch=25.4 mm. (+/_0A31") NOTE: Narrower shingles similar FIGURE 1—DaVINCI SLATE ROOF SHINGLES AND SHAKE ROOF SHINGLES 1 pg. 16114 151/2 Li, ECG 123'4 r 123/4 04/19/2024 FIGURE 2—BELLAFORTE SHAKE FIGURE 3—BELLAFORTE SLATE ASPEN BUILDING DEPARTMENT ESR-2119 I Most Widely Accepted and Trusted Page 3 of 7 3.16 Wind Resistance: specified in, those codes listed in Section 1.0 of this report, The allowable wind uplift pressures for the DaVinci roof subject to the following conditions: shingles described in this report are as noted in Table 2. 4.1 Installation must comply with the applicable code, the The roof shingles have maximum design wind speeds at manufacturer's published installation instructions and corresponding maximum roof heights as shown in Tables 3 this report. In the event of a conflict between this and 4. report and the manufacturer's published installation 3.17 Reroofing: instructions, this report governs. Prior to application of the shingles, the existing roof 4.2 The roof shingles are manufactured in Lenexa, covering and underlayment must be completely removed. Kansas, under a quality control program with inspections by ICC-ES. Any damaged sheathing must be replaced. The installation of the shingles must then proceed as described in 5.0 EVIDENCE SUBMITTED Sections 4.1 through 4.5. An existing self-adhered ice Data in accordance with the ICC-ES Acceptance Criteria barrier membrane may remain in place if covered with a for Special Roofing Systems (AC07), dated February 2014 new ice barrier membrane in accordance with the (editorially revised May 2016). applicable code. The roof classification is as noted in Section 4.6 and Table 1. 6.0 IDENTIFICATION 4.0 CONDITIONS OF USE Each roof shingle is labeled with the report holder's name(DaVinci Roofscapes, LLC)and address,the product The DaVinci Slate, DaVinci Shake, Bellaforte Shake, and name, the shingle width, a production date code, and the Bellaforte Slate roof shingles described in this report ICC-ES evaluation report number(ESR-2119). comply with, or are suitable alternatives to what is TABLE 1—FIRE CLASSIFICATIONS SYSTEM ROOF ROOF MIN. DaVINCI ROOF SHINGLE NO. CLASS DECK SLOPE UNDERLAYMENT Roof Shingle Exposure(in.) One layer ASTM D226 Type II (No.30)or two layers Min. 15/3z of ASTM D Type I (No. 15)asphalt-saturated organic 1 A 3:12 felt may be used;or DaVinci Slate 6 plywood Iyw ood One layer GAF Versashield®Fire-Resistant Roof Deck Protection(ESR-2053) 2 A Min. 15/32- 3:12 One layer GAF Versashield®Fire-Resistant Roof DaVinci Slate 6 to 71/2 inch plywood Deck Protection(ESR-2053) DaVinci Shake 9 to 10 Min. 15/32 One layer ASTM D226 Type II (No.30)asphalt- DaVinci Slate 6 to 8 3 A inch plywood 3:12 saturated organic felt plus one layer of ASTM D3909 DaVinci Shake 9 to 10 mineral-surfaced cap sheet Bellaforte Shake 12 DaVinci Slate 6 to 8 4 A Min. 15/32- 3:12 Two layers ASTM D226 Type II (No.30)asphalt- DaVinci Shake 9 to 10 inch plywood coated glass-fiber-mat Bellaforte Shake 12 Bellaforte Slate 12 DaVinci Slate 6 to 8 Min. 15/3z- One layer Eco Chief Products SolarHideTM-SRW DaVinci Shake 9 to 10 5 A 12 inch plywood 3. (ESR-4035) Bellaforte Shake 12 Bellaforte Slate 12 For SI: 1-inch=25.4 mm; 1ft=0.305m 1 ASTM D226 Type I (No. 15)and Type II (No. 30) underlayment must be installed in accordance with the applicable building code. GAF Versashield® Fire-Resistant Roof Deck Protection underlayment must be installed in accordance with ESR-2053. Eco Chief Products SolarHideTM-SRW underlayment must be installed in accordance with ESR-4035. RECEIVED 04/19/2024 ASPEN BUILDING DEPARTMENT G4RL/5LE WIP 300HT High-Temperature Protection Self-Adhering ® Roofing Underlayment WIP 300HT is a high-tensile-strength rubberized asphalt underlayment specifically designed to withstand temperatures up to 250°F(121°C).Ideal for use under metal including copper,zinc and 3 ?c?iii- COR-TEN®(consult technical department for installation instructions),WIP 300HT can also be W I P used under synthetic tiles and asphalt shingles.This strong,skid-resistant membrane is available WATER&ICE PROTECTION HIGH-TEMPERATURE PROTECTION 1 in either black or white and provides superior protection from water penetration caused by wind-driven rain and ice dams. Features and Benefits Standards • Protects the roof structure from water seepage caused by ice • UL Classified dams and wind-driven rains • ICC-ES ESR#2206 • Resists temperatures up to 250°F without degradation of • 2009 International Building Code- the adhesive • State of Florida Approved Product FSA#FL6782 • Seals around roofing nails,staples and screws • Meets ASTM D1970 • Bonds directly to the roof substrate for fast and easy installation without the need for additional adhesives Storage • Split-release film provides easier,faster installation • Resists cracking,drying and rotting,providing long-term WIP 300HT roofing underlayment rolls should be stored on end,under waterproofing performance and low lifecycle cost cover and in areas where the temperature is between 40°and 100°F (4.4°and 38°C).Do not double-stack pallets. • Concealed waterproofing system will not detract from the architectural aesthetics of the primary roofing system Warranty • Exposed rubberized asphalt bead along the membrane edge ensures watertightness of lap seams Carlisle WIP products are backed by Carlisle's industry-leading warranty. Visit our website for warranty details. • �. Ridge Line ,';:g-_ _ i. . Ce s Rake Edge r Skylights 'I. Flashing . wit J . = Dormers -_ _ \4111'-- Low-Slope Eaves I I se [I , .�NMI fi,,...,_.,_ .r, . _ a -- . . - -., . , G4RLI5LE WIP 300HT High-Temperature Protection Self-Adhering Roofing Underlayment METAL PRODUCTS Installation Metal Roof Underlayment WIP 300HT underlayment is a lied when the roof deck is dr and Under water-shedding metal roof systems or low-slope metal roofs with the substrate temperature is 40°F(4.4°C)or higher.At temperatures a minimum 1/z"slope,start at the low point and apply WIP 300HT over below 40°F,nailing or priming should be used to temporarily hold the the full surface of the roof deck.Review the metal roofing manufacturer's membrane in place while adhesion develops.WIP 300HT is designed to instructions for limitations and precautions.Beginning at the eaves,apply be covered with the primary roofing system and should not be exposed underlayment from the low point to the high point of the roof,running the to sunlight for more than 60 days.White underlayment offers exposure roll horizontally. time of 120 days. Limitations Moisture • WIP 300HT should be installed when air,roof deck and Substrate must be free of any moisture.If moisture is present,it may membrane temperatures are at or above 40°F(4.4°C). inhibit adhesion. • WIP 300HT should not be left exposed to sunlight for more than 60 days for black membrane or 120 days for white membrane. New Construction Prepare the roof deck by removing all loose objects,dirt,dust and debris. • WIP 300HT membrane should not be folded over the roof edge unless protected by a gutter or other flashing materials. Re-roofing • The primary roof system must be ventilated to prevent excessive Remove all old materials from the roof deck in the area to be covered with moisture build-up in the interior structure. WIP 300HT underlayment.Replace water-damaged sheathing and sweep • Use caution during the installation of the membrane as it may roof deck thoroughly. become slippery when wet or covered with frost. Priming • WIP 300HT must not to be used in contact with flexible PVC material. Priming is not required on clean,dry wood or metal surfaces but concrete masonry,exterior gypsum board and polyisocyanurate insulation should be primed using the appropriate primer or adhesive.Adhesives such as PRODUCT SPECIFICATIONS CCW-702 and CAV-GRIP'"are appropriate and required when temperatures •HYSICAL PROPERTIES - aN are below 40°F. Black/White Engineered Polyolefin Surface Composite Film with Factory-applied Valleys, Hips& Ridges Anti-skid Coating Membrane Rubberized Asphalt Cut WIP 300HT roofing underlayment into manageable lengths.Align over PRODUCT CHARACTERISTIC the center of the valley,hip or ridge.Remove release film.Press the middle Roll Length feet 66 of the membrane first before working toward the edges.For open valleys, Roll Weight Ibs 55 cover WIP 300HT roofing underlayment with metal valley liners. Roll Size sq/ft 198 Eaves& Rakes Roll Width inches 36 TYPICAL PERFORMANCE PROPERTIES Cut WIP 300 HT underlayment into 10-15'pieces.Remove 2-3'of release Thickness ASTM D1970 40 mils film and align the edge of the membrane,sticky side down,so it overhangs Low Temperature Flexibility ASTM D1970 -45°F the drip edge by 3/8"(10 mm).Continue to remove release film and press as Adhesion to Plywood at 75°F 1 ASTM D1970 35 Ibs/ft you move across the roof.Use a hand roller and/or hand pressure to press Lap Seam Adhesion at 75°F ASTM D1970 21 Ibs/ft into place.Overlap end laps a minimum of 6".WIP roofing underlayment Sealability Around Nail ASTM D1970 Pass should reach a point 2'inside the interior wall line.Local codes may require _Slip Resistance ASTM D1970 Pass _ additional courses.If additional courses are required,the top lap must be at Thermal Stability ASTM D1970 Pass least 31/2°. Moisture Vapor Permeance ASTM D1970 0.02 perms Water Absorption ASTM D1970 0.5% _ Drip Edges Tensile Strength Machine Direction ASTM D412 250 psi At the rake edge,apply WIP 300HT underlayment first and place drip edge Tensile Strength Transverse Direction ASTM D412 1390 psi on top.At the eave,apply drip edge first and place WIP underlayment on top Elongation at Break Machine Direction ASTM D412 250% of the drip edge so that it overhangs drip edge by 3/s"(10 mm). Elongation at Break Transverse Direction ASTM D412 170% PACKAGING INFORMATION For standard installation details,follow the WIP detail drawings.For I Boxes(rolls)per pallet non-standard installation instructions,contact your local Carlisle —REEIVED— Residential representative. C 04/19/2024 P.O.Box 7000 / Carlisle,PA 17013 / Phone:800.479.6832 / Fax:717.245.7053 / www.carlislemetalproducts.com Carlisle,WIP and CAV-GRIP are trademarks of Carlisle.COR-TEN is a registered trademark of U.S.Steel.121311©2011 Carlisle. ASPEN NnsnEr, BUILDING DEPARTMENT ICC ESEVALUATION SERVICE® _ —+ _ • ; :f n t 14 • Compliance with International Codes c j'lT o, • Compliance with State Codes www.icc-es.orq I (800)423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® ICC-ES Evaluation Report Reissued June 2022 ESR-2206 This report is subject to renewal June 2024. DIVISION: 07 00 00—THERMAL AND MOISTURE Attributes verified: PROTECTION See Section 3.0 Section: 07 30 05—Roofing Felt and Underlayment 2.0 USES REPORT HOLDER: CCW WIP 300HT and CCW WIP 401 LT roof CARLISLE COATINGS&WATERPROOFING, INC. underlayments are self-adhering membranes used as alternatives to the ice barrier specified in IBC Chapter 15 EVALUATION SUBJECT: and IRC Chapter 9, respectively. 3.0 DESCRIPTION CCW WIP 300HT AND CCW WIP 401 LT ROOF UNDERLAYMENTS CCW WIP 300HT and CCW WIP 401 LT membranes are normally 40 mils (1.02 mm) thick and are composed of ADDITIONAL LISTEES: rubberized asphalt and textured laminated polyethylene film. The membranes are backed with a release film that DREXEL METALS serves to protect the membrane adhesive and to prevent self-adhesion of the material.The membranes are supplied NEW CASTLE BUILDING PRODUCTS in rolls 36 inches (914 mm)wide and either 66 feet (20 m) or 75 feet (23 m) long. The membranes are considered to AEP SPAN, DIVISION OF ASC PROFILES be vapor barriers. CCW WIP 300HT and CCW WIP 401 LT are treated for various temperature conditions. See Table 1 PAC-CLAD/PETERSEN for company name and product name correlation. The attributes of the CCW WIP 300HT and CCW WIP 401 1.0 EVALUATION SCOPE LT roof underlayments have been verified as conforming to 1.1 Compliance with the following codes: the provisions of (i) CALGreen Section A4.407.5; (ii) ICC 700-2020 Sections 602.1.13, 11.602.1.13, 1202.9 • 2021, 2018, 2015, 2012 and 2009 International Building and 13.104.1.7; (iii) ICC 700-2015 and ICC 700-2012 Code®(IBC) Sections 602.1.13, 11.602.1.13 and 12.5.602.1.14; and (iv) • 2021, 2018, 2015, 2012 and 2009 International ICC 700 2008 Section 602.10 for ice barriers. Note that Residential Code®(IRC) decisions on compliance for those areas rest with the user of this report. The user is advised of the project-specific • 2013 Abu Dhabi International Building Code(ADIBC)t provisions that may be contingent upon meeting specific tThe ADIBC is based on the 2009 IBC.2009 IBC code sections referenced conditions,and the verification of those conditions is outside in this report are the same sections in the ADIBC. the scope of this report. These codes or standards often provide supplemental information as guidance. Properties evaluated: 4.0 INSTALLATION • Physical properties 4.1 General: • Water resistance 1.2 Evaluation to the following green code(s) and or Installation of the membranes must comply with the standards: requirements of the applicable code, this report and the report holder's or additional listee's published installation • 2019 California Green Building Standards Code instructions. The installation instructions must be available (CALGreen),Title 24, Part 11 at the jobsite at all times during installation. • 2020, 2015, 2012 and 2008 ICC 700 National Green Prior to application of the membranes, the plywood Building StandardTM (ICC 700-2020, ICC 700-2015, ICC substrate surface must be free of frost, dust and dirt, loose 700-2012 and ICC 700-2008) nails, and other protrusions. Damaged sheathing must be _l . T.w i ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to U - ( as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or inipll as ` to any finding or other matter in this report,or as to any product covered by the report. /�f o Copyright©2022 ICC Evaluation Service,LLC. All rights reserved. 0 /, pag i oT34 ASPEN BUILDING DEPARTMENT ESR-2206 I Most Widely Accepted and Trusted Page 2 of 3 replaced.Installation of the membranes is limited to plywood 5.5 Installation is limited to use with roof coverings that are substrates complying with the requirements of the mechanically fastened through the underlayment to the applicable code. The membranes must be applied only sheathing or rafters. when the ambient air and plywood substrate temperatures 5.6 Installation is limited to roofs with ventilated attic are above 40°F(4.4°C)as specified in the report holder's or spaces, in accordance with the requirements of the additional listee's installation instructions. applicable code. Vertical ends and horizontal edges must be overlapped a 5.7 The membranes are manufactured in Terrell, Texas, minimum of 6 inches (152 mm) and 3'/2 inches (89 mm), under a quality-control program with inspections by respectively. Starting at the lower edge at the eave of the ICC-ES. roof, the membrane is applied a minimum of two sheets wide such that the membrane extends a minimum of 6.0 EVIDENCE SUBMITTED 24 inches (610 mm) inside the exterior wall line of the 6.1 Data in accordance with the ICC-ES Acceptance building. Criteria for Self-adhered Roof Underlayments for Use If the membrane becomes misaligned,the roll must be cut as Ice Barriers (AC48), dated February 2012 and restarted. The membrane must be pressed firmly into (editorially revised February 2021). place, from the center to the edge. After application, the 6.2 Reports of testing in accordance with ASTM D1970. membrane must be inspected, and any defects repaired. "Fish mouths"must be slit, pressed flat,and covered with a 7.0 IDENTIFICATION patch of membrane of sufficient width and length to overlap 7.1 The membranes are identified by labels on boxes each side and end of the slit a minimum of 6 inches displaying the Carlisle Coatings&Waterproofing, Inc., (152 mm). Flashing around protrusions must be installed name and address (or additional listee's name and over the membranes,to prevent water backup. Where drip address),product name,and evaluation report number edges are installed, the ice barrier must be installed over (ESR-2206). drip edges along eaves and under drip edges along rake edges. 7.2 The report holder's contact information is the following: Installation of the roof covering can proceed immediately CARLISLE COATINGS&WATERPROOFING, INC. following application of the membranes. The membranes 900 HENSLEY LANE are not intended to be left exposed and must be covered by WYLIE, TEXAS 75098 an approved roof covering within the time set forth in the (972)442-6545 membrane report holder's or additional listee's published www.carlislewipproducts.com installation instructions. 7.3 The additional listees' contact information is the 4.2 Reroofing: following: For reroofing applications, the same preparation as DREXEL METALS described in Section 4.1 applies, after the removal of the 1234 GARDINER LANE existing roof covering materials to expose the roof deck. LOUISVILLE, KENTUCKY 40213 5.0 CONDITIONS OF USE (888)321-9630 The CCW WIP 300HT and CCW WIP 401 LT www.drexmet.com underlayments described in this report comply with, or are NEW CASTLE BUILDING PRODUCTS acceptable alternatives to what is specified in,those codes 535 OLD TARRYTOWN ROAD listed in Section 1.0 of this report, subject to the following WHITE PLAINS, NEW YORK 10603 conditions: (914) 358-8100 www.ncbp.com 5.1 Installation must comply with the requirements of the applicable code, this report and the report holder's or AEP SPAN, DIVISION OF ASC PROFILES additional listee's published installation instructions. In 2110 ENTERPRISE BLVD. the event of conflict between this report and the report WEST SACRAMENTO, CALIFORNIA 95691 holder's or additional listee's published installation (800) 733-4955 instructions, this report governs. www.aepspan.com 5.2 Installation is limited to use on plywood roof substrates PAC-CLAD/PETERSEN on structures located in areas where 1005 TONNE ROAD non-classified roof assemblies are permitted. ELK GROVE VILLAGE, IL 60007 5.3 Installation is limited to roofs with a slope of 2:12 (800)722-2523 www.pac-clad.com (16.67%)or greater. 5.4 Installation is limited to use with roof coverings that do not involve hot asphalt or coal-tar pitch. TABLE 1—COMPANY NAME AND PRODUCT NAME CORRELATION CARLISLE COATINGS& NEW CASTLE BUILDING AEP SPAN,DIVISION PAC-CLAD/ WATERPROOFING INC. PRODUCTS DREXEL METALS OF ASC PROFILES PETERSEN CCW WIP 300HT MetShield HT High-Temp New Castle HT AEP Span PAC-CLAD HT Underlayment Underlayment HT CCW WIP 401 LT — — — RECEIVED 04/19/2024 ASPEN BUILDING DEPARTMENT ESICC EVALUATION SERVICE' ICC-ES Evaluation Report ESR-2206 CBC and CRC Supplement Reissued June 2022 This report is subject to renewal June 2024. www.icc-es.orq I (800)423-6587 I (562) 699-0543 A Subsidiary of the International Code Council° DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 30 05—Roofing Felt and Underlayment REPORT HOLDER: CARLISLE COATINGS&WATERPROOFING, INC. EVALUATION SUBJECT: CCW WIP 300HT AND CCW WIP 401 LT ROOF UNDERLAYMENTS 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that CCW WIP 300HT and CCW WIP 401 LT roof underlayments, described in ICC-ES evaluation report ESR-2206, have also been evaluated for compliance with the codes noted below. Applicable code editions: • 2019 California Building Code°(CBC) For evaluation of applicable chapters adopted by the California Office of Statewide Health Planning and Development (OSHPD)AKA: California Department of Health Care Access and Information (HCAI)and Division of State Architect (DSA), see Sections 2.1.1 and 2.1.2 below. • 2019 California Residential Code°(CRC) 2.0 CONCLUSIONS 2.1 CBC: The CCW WIP 300HT and CCW WIP 401 LT roof underlayments, described in Sections 2.0 through 7.0 of the evaluation report ESR-2206, comply with CBC Chapter 15 provided the design and installation are in accordance with the 2018 International Building Code°(IBC)provisions,as applicable, noted in the evaluation report and the additional requirements of CBC Chapter 15, as applicable. The CCW WIP 300HT and CCW WIP 401 LT roof underlayments have not been evaluated under CBC Chapter 7A for use in the exterior design and construction of new buildings located in any Fire Hazard Severity Zone within State Responsibility Areas or any Wildland-Urban Interface Area. 2.1.1 OSHPD: The applicable OSHPD Sections of the CBC are beyond the scope of this supplement. 2.1.2 DSA: The applicable DSA Sections of the CBC are beyond the scope of this supplement. 2.2 CRC: The CCW WIP 300HT and CCW WIP 401 LT roof underlayments, described in Sections 2.0 through 7.0 of the evaluation report ESR-2206, comply with CRC Chapter 9, provided the design and installation are in accordance with the 2018 International Residential Code°(IRC)provisions,as applicable, noted in the evaluation report and the additional requirements of CRC Chapter 9, as applicable. The CCW WIP 300HT and CCW WIP 401 LT roof underlayments have not been evaluated under CRC Section R337 for use in the exterior design and construction of new buildings located in any Fire Hazard Severity Zone within State Responsibility Areas or any Wildland-Urban Interface Area. The products described in this supplement has not been evaluated for compliance with the International Wildland—Urban Interface Code®. This supplement expires concurrently with the evaluation report, reissued June 2022. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service.LLC,express or i .h , to any.finding or other matter in this report,or as to any product covered hr the report. 04/1'9/2024 Copyright°2022 ICC Evaluation Service,LLC. All rights reserved. Page 3 of 3 ASPEN BUILDING DEPARTMENT ECO CHIEF I ir - I.7;\' tkp- _ 4THE ENERGY SAVING UNDERLAYMENT SOLAR HIDE AN ENERGY SAVING ADDITION FOR ANY ROOF SYSTEM, INCLUDING ASPHALT SHINGLES ATTIC TEMPS UP TO 30° COOLER WHEN PROPERLY INSTALLED AS A RADIANT BARRIER DURABLE & SLIP RESISTENT, EXCEEDS MIAMI DADE SPECIFICATIONS SYNTHETIC & 100% RECYCLABLE 10 SQ. ROLL (48" X 2501 ECEIVED 04/19/2024 �sTh QIH �'f '�{ ;1F_[ESft-0a35 w���rw� °A' ItI-)IIOL JLIJ �•�' • • L _ p' SAVES ENERGY! SOLARHIDE .► .. SOLARHIDE-SRW is a durable and energy saving one-step radiant barrier roofing underlayment. SOLARHIDE-SRW can significantly increase energy savings and overall energy efficiency of a structure. The unique design of SOLARHIDE-SRW allows it SOLARHIDE-SRW ALSO to reflect up to 97% of the radiant heat it MEETS CLASS A FIRE encounters. When installed with the REQUIREMENTS WITH ANY reflective surface facing an air space in the OF THESE ROOF COVERINGS: roof system, SOLARHIDE-SRW acts as a radiant barrier dramatically reducing radiant heat transfer. Roof assemblies installed -0" with batten systems are excellent �' r� applications for the use of SOLARHIDE-SRW —r--t underlayment. SOLARHIDE-SRW has also f been proven effective at reducing heat transfer under asphalt shingles. (Although Asphalt Shingles Slate effective, this application cannot be ,‘11,410- classified as a "radiant barrier"). 4411011114114 - #11°IP"_ SOLARHIDE-SRW can be used with most any steep slope roofing assembly: Metal, Wood, %Oh PIN Slate, Clay Tile, Stone Coated Steel, Concrete Tile, and Asphalt Shingles. Concrete Tile Clay Tile SOLARHIDE-SRW is a vapor barrier and should always be installed on roof systems with adequate ventilation. Rip Installs Synthetic ` ,14.t1 Resistant Quickly & Recyclable Synthetic Slate Synthetic Shake ....*"/ 11111:LIIIE!1(eleelle._ SOLARHIDE SOLARHIDE-SRW roof underlayment, 1 t\ roof deck so, \ \\, \ w.. t metal dApedge ,,, \ OLARHIOE' � \ on toe°f \1` 5 sOLARHIDE _ ------‘:::------- \ (side 1il1' o \\ tt\ — 6"inch (end laps) 'When used with batten roof systems.SOLARHIDE should be installed shiny side up. SOLARHIDE performs best with the shiny side facing an air space. CAUTION - Always follow OSHA safe roofing codes & practices when installing any roofing product. Workers should always use and wear fall protection devices when working on a roof. Proper high traction footwear, toe boards, ropes and harnesses should always be a part of your safety measures. Use extra caution on SOLARHIDE-SRW if it becomes wet or dusty, as this may reduce traction. Serious injury or death can occur if you fail to use proper safety gear and footwear. 04/19/2024 ACC Chan A Fire Wing \ 1EM376 QIII MIAMFDADE COUNTY ® APPROVED J US ESR-4035 u,:Doflzamsa-I SOU4eDE rbnea Pro..I Avon..rug no - TM USE SOLARHIDE FOR A COOLER ROOF SYSTEM! + j JUMP _ � �`r likshib, SOLARHIDE INSTALL INSTRUCTIONS Safety First! Always use on 05HA approved fall protection system, and carefully observe safe roofing codes and practices. OSHA 1926.502 I MAKE SURE YOUR ROOF DECK IS CLEAN AND DRY. REMOVE ANY DEBRIS OR FASTENERS THAT MAY BE PROTRUDING FROM THE ROOF DECK. 2.SOLARHIDE-SRW SHOULD BE INSTALLED HORIZONTALLY(PARALLEL)TO THE EAVE OF THE ROOF. INSTALL SOLARHIDE-SRW WITH 4'INCH HORIZONTAL OR SIDE LAPS,AND 6"INCH VERTICAL OR END LAPS, FOR LOW SLOPE ROOFS WITH A PITCH LESS THAN 4:12.OVERLAP SOLARHIDE-SRW AT LEAST 24"INCHES HORIZONTALLY OVER THE UNDERLYING COURSE AND INCREASE END LAPS TO 8"INCHES. 3.ALWAYS USE CORROSION RESISTANT PLASTIC CAP NAILS,PLASTIC CAP STAPLES,OR TIN CAP NAILS.WITH AT LEAST 1'INCH DIAMETER PLASTIC/METAL HEAD TO ATTACH SOLARHIDE-SRW TO THE ROOF DECK. FASTENERS SHOULD PENETRATE THE ROOF DECK TO A MINIMUM DEPTH OF 3/4"INCH. FASTEN THE HORIZONTAL AND END LAPS EVERY 6"INCHES AT CENTER ALONG THE CENTER OF THE ROLL IN THE FIELD. ALL FASTENERS MUST BE AT 90 DEGREES TO THE ROOF DECK AND DRIVEN FLUSH WITH SOLARHIDE-SRW 4.IF THE ROOF SYSTEM REQUIRES THE USE OF SEALANTS ON THE SEAMS AND JOINTS.USE A HIGH QUALITY. LOW SOLVENT,PLASTIC ROOFING CEMENT.MEETING ASTM D-4586 TYPE 1 REQUIREMENTS. ALWAYS CONSULT THE MANUFACTURER'S APPLICATION INSTRUCTIONS. 5.SOLARHIDE-SRW SHOULD BE COVERED WITH THE FINAL ROOFING MATERIALS WITHIN 180 DAYS OF BEING INSTALLED. SOLARWIDE-SAW is one component of a high quality roof system. Always make sure your roof s stemb proper ventilation, and be sure to check and follow all applicREeyEl E SOLARH/DE-SRW meets or exceeds requirements for ASTM P-226 Type OIini 'c/2b2 4 888.733.2640 ASPEN www.EcoChiefProducts.com BUILDING DEPARTMENT VANCOUVER,BC: 877.461.8378 ph. 604.527.8368 fx. LOS LABORATORIES WASHING ON,DC: 540.63694455 pph. 09.483.0336 fx. h. 540.636.9414 fx. TULSA,OK: 918.437.8333 ph. 918.437.8487 fx. CERTIFICATION TESTING INSPECTION TORONTO,ON 416.550.9280 SEATTLE,WA 425.512.8419 WEBSITE: WWW.QAI.ORG BUILDING PRODUCTS LISTING PROGRAM Customer: Eco Chief Products 4605 Old Denton Rd Haltom City, TX 76117 Class: Roofing Underlayments Location: Haltom City, TX Listing No. B1094 Project No. B1094-1, Edition 1 Effective Date: August 1, 2016 Last Revised Date: August 1, 2016 Expires: <N/A> Standards: ASTM E108 — "Standard Test Methods for Fire Tests of Roof Coverings." Also complies with performance requirements of: ASTM D226 — "Standard Specification for Asphalt-Saturated Organic Felt Used in Roofing and Waterproofing." ASTM D4869 — "Standard Specification for Asphalt-Saturated (Organic Felt) Underlayment Used in Steep Slope Roofing" Product: SOLARHIDETM Roofing Underlayment. Markings: Listed products are identified with a label bearing the following information: • Product name • Company name, logo, address and phone number • Manufacturing plant address, including city and state of manufacture • QAI logo with 'us' indicators • QAI Certification Listing Number (B1094-1) • Information for traceability • Roll length and width Models : MODEL WIDTH LENGTH WEIGHT SOLARHIDETM 48 inches 250 ft 5.24 Ibs/100 ft2 Roofing (1.2 m) (76.2 m) (256 g/m2) Underlayment RECEIVED 04/19/2024 WWW.QAI.ORG Page 1 of 3 info@gai.org ASPEN BUILDING DEPARTMENT o 1) LAB 0 RATO R I E S WASHIN ON,DC: 540.636.9445 ph. 540.636.9414 fr. TULSA,OK: 918.437.8333 ph. 918.437.8487 fx. CERTIFICATION TESTING INSPECTION TORONTO,ON 416.550.9280 SEATTLE,WA 425.512.8419 WEBSITE: WWW.QAI.ORG Ratings: The following outlines physical property classification of QAI certified Eco Chief Roofing Underlayment products: Eco Chief Roofing Underlayment— Physical Property Specifications PRODUCT TEST METHOD CLASSIFICATION SOLARHIDETM Roofing ASTM D2261 Type II Underlayment ASTM D4869 Meets Requirements Note 1: ASTM D226 and ASTM D4869 outline specifications for asphalt- impregnated organic felt materials. Eco Chief non-asphalt underlayment products in this table were tested and found to comply with the performance specifications outlined in D226and D4869 for the classifications noted. The following outlines roof fire classifications of QAI certified Eco Chief underlayment products: Eco Chief Roofing Underlayment — Class A Roof Fire Assembly (No Slope Limitations) SHEATHING UNDERLAYMENT ROOF COVERING One layer of Class A listed* three-tab asphalt roof shingles, or equivalent, complying with ASTM D3018, and having a minimum SOLARHIDETM installed weight of 180 pounds Roofing per 100 ft2 (9.28 kg/m2), Underlayment installed per the manufacturer's installation Minimum 15/32" Minimum single instructions. Exposure 1 layer mechanically Plywood fastened with Brick, masonry, slate, clay or overlaps per concrete roof tile, exposed manufacturer's concrete roof decks. installation instructions. DaVinci Shake, DaVinci Slate, DaVinci Bellaforte Shake, DaVinci Bellaforte Slate, DaVinci Valore, DaVinci Valore Slate (as described in QAI Listing B1050) * Note 1: Asphalt Shingles are listed Class A componei's CFN ED 1/19/2024 WWW.QAI.ORG Page 2 of 3 info@gai.org ASPEN BUILDING DEPARTMENT LOS ANGELES,CA: 909.483.0250 ph. 909.483.0336 fx. LAB 0 RATO R I E S WASHIN ON,DC: 540.636.9445 ph. 540.636.9414 fx. 141111 TULSA,OK: 918.437.8333 ph. 918.437.8487 fx. CERTIFICATION TESTING INSPECTION TORONTO,ON 416.550.9280 SEATTLE,WA 425.512.8419 WEBSITE: WWW.QAI.ORG deck assembly by an Approved Agency. The third party program in which products are certified, carry a label, and are listed in the directory of an agency accredited by the International Accreditation Service, Inc. (IAS), or by an accredited body that is a partner with IAS in a mutual recognition arrangement, pertaining to certification bodies and their compliance with ISO/IEC Guide 65, General Requirements for Bodies Operating Product Certification Systems. The asphalt shingle components are to meet Class A Classification when tested to ASTM E108. Notes: The product must be installed in accordance with the code enforced by the authority having jurisdiction. Final acceptance of the product in the final installation is subject to inspection by the authority having jurisdiction. The materials, products or systems listed herein have been qualified to bear the QAI Listing Mark under the conditions stated with each Listing. Only those products bearing the QAI Listing Mark are considered to be listed by QAI. No warrantee is expressed or implied, and no guarantee is provided that any jurisdictional authority will accept the Listing found herein. The appropriate authorities should be contacted regarding the acceptability of any given Listing. Visit the QAI Online Listing Directory located at www.gai.org for the most up to date version of this Listing and to validate that this QAI Listing is active. Questions regarding this listing may be directed to info(@.gai.orq. Please include the listing number in the request. *** RECEIVED 04/19/2024 WWW.QAI.ORG Page AgF2EN info@gai.org BUILDING DEPARTMENT ESICC EVALUATION SERVICE' ICC-ES Evaluation Report ° h° :° ESR-4035 Reissued September 2022 13-.:. This report is subject to renewal September 2024. www.icc-es.org I (800)423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE The attributes of the SolarhideTM-SRW roofing PROTECTION underlayment have been verified as conforming to the Section: 07 30 05—Roofing Felt and Underlayment provisions of (i) CALGreen Section A4.407.5; (ii) ICC 700- 2020 Section 602.1.13, 11.602.1.13, 1202.9 and REPORT HOLDER: 13.104.1.7; (iii) ICC 700-2015 Sections 602.1.13, 11.602.1.13 and 12.6.602.1.13; (iv) ICC 700-2012 Sections ECO CHIEF PRODUCTS 602.1.13, 11.602.1.13 and 12.5.602.1.14; and (v) ICC 700- 2008 Section 602.10 for ice barriers. Note that decisions on EVALUATION SUBJECT: compliance for those areas rest with the user of this report. The user is advised of the project-specific provisions that SOLARHIDETM-SRW ROOFING UNDERLAYMENT may be contingent upon meeting specific conditions, and the verification of those conditions is outside the scope of 1.0 EVALUATION SCOPE this report. These codes or standards often provide 1.1 Compliance with the following codes: supplemental information as guidance. 4.0 INSTALLATION • 2015 and 2012 International Building Code°(IBC) 4.1 General: • 2015 and 2012 International Residential Code°(IRC) Installation must comply with the applicable code,this report Properties evaluated: and the report holder's published installation instructions. • Physical properties The report holder's published installation instructions must be available at the jobsite at all times during installation. • Ice barrier Prior to application of the underlayment,the deck surface • Fire Classification must be free of frost, dust and dirt, loose fasteners, and 1.2 Evaluation to the following green code(s) and/or other protrusions. Damaged sheathing must be replaced. standards: Installation is limited to solid or closely fitted substrates California Green Building Standards Code complying with the requirements of the applicable code. • 2019 (CALGreen),Title 24, Part 11 Installation of an approved roof covering can proceed immediately following application of the roofing • 2020, 2015, 2012 and 2008 ICC 700 National Green underlayment. The underlayment is to be covered by the Building StandardTM (ICC 700-2020, ICC 700-2015, ICC roof covering within the time set forth in the underlayment 700-2012, and ICC 700-2008) report holder's published installation instructions. For reroofing applications, the same procedures apply after Attributes verified: removal of the existing roof coverings and roofing felts to • See Section 3.0 expose the roof deck. 2.0 USES 4.2 Applications: SolarhideT""-SRW roofing underlayment is an alternative to The underlayment must be installed in accordance with the ASTM D226, Type I and Type II, roofing underlayment IBC Chapter 15 or IRC Chapter 9 and may be laid with either specified in IBC Chapter 15 and IRC Chapter 9. The side up starting at the lower edge of the roof, with underlayment may also be used as a component of a 4-inch (102 mm) horizontal (head) laps and 6-inch classified roof assembly as described in Section 4.5 of this (152 mm)vertical(end)laps. report. The underlayment must be fastened to the roof deck using 3.0 DESCRIPTION minimum No. 12 gage [0.109 inch (2.77 mm)] minimum shank diameter, corrosion-resistance steel roofing nails SolarhideTM-SRW roofing underlayment consists of having a minimum 3/s-inch-diameter (9.5 mm) heads or laminated layers of woven and non-woven polyethylene minimum 1-inch-diameter (25.4 mm) plastic cap; or No. and polypropylene fabrics faced on one side with aluminum 16 gage [0.065 inch leg diameter (1.65 mm)] corrosion- foil. The underlayment is supplied in 48-inch wide resistant staples having minimum 7/16-inch (1219 mm) rolls and has an installed weight of (11.1 mm)crowns with minimum 1-inch-diamter(25.4 mm) 5.18 pounds per 100 square feet (0.253 kg/m2). The plastic caps. The fasteners must be spaced 6 inches underlayment may be installed with either side facing up. (152 mm)on center along both horizo eI �{ lt ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,0 4 2 4 to any finding or other matter in this report,or as to any product covered by the report. g� .. Copyright©2022 ICC Evaluation Service,LLC. All rights reserved. ASPEN of 2 BUILDING DEPARTMENT ESR-4035 I Most Widely Accepted and Trusted Page 2 of 2 and 12 inches (305 mm)on center along the middle of the 5.1 Installation must comply with this report and the report roll in the field of the roof, except in areas subject to high holder's published installation instructions, and the winds where underlayment fastening must comply with high applicable code. In the event of conflict between the wind attachment requirements specified in IBC Section published installation instructions and this report, this 1507 or 2015 IRC Section R905.1.1 [2012 IRC Section report governs. R905], as applicable. Fasteners must be long enough to 5.2 This report recognizes the use of SolarhideTM-SRW as penetrate into the sheathing a minimum of a roof underlayment only. Use of this product as a 3/4 inch (19.1 mm) or through the sheathing, whichever is radiant barrier is outside the scope of this report. less.When battens are installed over the underlayment,the underlayment needs only be preliminarily attached pending 5.3 Installation must be limited to roofs with a minimum attachment of the battens or counterbattens. slope of 2:12 (17 percent slope) or to the minimum A single layer of minimum 24-inch-wide (610 mm) slope required for the roof covering in accordance with underlayment must be installed and centered vertically at all the applicable code,whichever is greater. valleys before underlayment in the field, and at all hips and 5.4 Installation must be limited to use with roof coverings ridges after underlayment in the field. that do not involve hot asphalt or coal-tar pitch. 4.3 Ice Barrier: 5.5 Installation must be limited to use with solid substrates In areas of the roof required to have an ice barrier under IBC complying with the applicable code. Chapter 15 or IRC Chapter 9, a self-adhering 5.6 Unless installed in accordance with Section 4.5 of this polymer-modified bitumen sheet or a membrane currently report, installation must be limited to use with solid recognized in an ICC-ES evaluation report as a substrates located in areas where nonclassified roof self-adhered roof underlayment must be installed and coverings are permitted, or as a component of extend a minimum of 24 inches(610 mm)inside the exterior classified roofing assemblies when specifically wall line of the building. The roof underlayment, in the field recognized as such in a listing approved by the code of the roof, must overlap the ice barrier. official. 4.4 Flashing: 5.7 Installation must be limited to use with roof coverings Flashing must be in accordance with the applicable code. that are mechanically fastened through the Flashing around protrusions must be over the lower course underlayment to the sheathing or rafters. of the underlayment and under the upper course of the 5.8 Installation must be limited to roofs with ventilated attic underlayment, to prevent water backup. When used, metal spaces in accordance with the requirements of the drip edges must be installed beneath the underlayment at applicable code. the eaves and over the underlayment at rakes. 5.9 The underlayment is manufactured in Hangzhou, 4.5 Classified Roofs: China,under a quality control program with inspections The SolarhideTM-SRW roofing underlayment may be used by ICC-ES. as a component of the following Class A roof assembly: 6.0 EVIDENCE SUBMITTED • Deck: Closely fitted, minimum 15/32-inch-thick Data in accordance with the ICC-ES Acceptance Criteria for (11.9 mm)exterior grade plywood. Roof Underlayments (AC188), dated February 2012 • Maximum roof slope: Unlimited, minimum roof slope (editorially revised December 2015). must be as described in ESR-2119. 7.0 IDENTIFICATION • Underlayment: One layer of SolarhideTM-SRW with 7.1 The SolarhideTM-SRW roofing underlayment described either side facing up in lieu of the underlayment in this report is identified by a label on each roll bearing specified in Sections 4.6.3 and 4.6.4 of ESR-2119. the report holder's name (Eco Chief Products) and • Roof Covering: DaVinci Roofscapes, LLC Bellaforte address, product name, date of manufacture and the Shake, Bellaforte Slate, DaVinci Slate or DaVinci evaluation report number(ESR-4035). Shake roof shingles installed with a maximum 7.2 The report holder's contact information is the following: exposure of 12 inches (304 mm) in accordance with ECO CHIEF PRODUCTS ESR-2119. 4605 OLD DENTON ROAD 5.0 CONDITIONS OF USE HALTOM CITY,TEXAS 76117 The SolarhideTM-SRW described in this report complies (817) 503-2121 with,or is a suitable alternative to what is specified in,those www.ecochiefproducts.com RECEIVED codes listed in Section 1.0 of this report, subject to the following conditions: 0 4/19/2 02 4 ASPEN BUILDING DEPARTMENT