Loading...
HomeMy WebLinkAboutFile Documents.617 W Bleeker St.0052-2022-BCHO (9)REVISION CHANGES REV.DESCRIPTION DATE APPROVED A AS DRAWN 4/19/2022 CR B ADDED AQUAFUZION, PEROXIDE PUMP 8/15/2022 CR DSI Internal Use Only: Fabrication Plumbing Project Management Sales SHEET OF DRAWN CHECKED UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES. DO NOT SCALE DRAWING MATERIAL FINISH Rotary Hand Brushed THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF DIAMOND SPAS INC. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF DIAMOND SPAS INC. IS PROHIBITED. 4409 Coriolis WayFrederick, CO 80504ph. 720-864-9115 1-800-951-SPASfax. 1-866-605-2358 CR 8/15/2022CS 8/15/2022 1 6 304 / 316 L STAINLESS STEEL REVISION B HYDROSPA 4557 - BLEEKER IAPMOEGS ELECTRICAL 1) Electrical requirements are specified for each unit. Only a licensed qualified electrician should connect the power supply. 2) Some units require more than one supply circuit. All power supply circuits must be located in the same disconnect box. (per NEC) Disconnect box must be more than 5(five) feet away from the tub and less than 50(fifty) feet away and within sight of spa. 3) All spas require a continuous bond. All spas are shipped with a bond connection on the frame. This connection must be made in the field. 4) Never turn the power on to the spa if it is empty. The spa needs water to properly test and satisfy diagnostic computations. 5) All electrical supply to the tub must be GFCI protected. 6) Any nearby electrical outlets, windows, hand rails or metal fencing may have special bonding requirements. Consult your licensed qualified electrician. 7) The communication cables for touch pad, low voltage lighting and water level sensors must be housed in separate conduits from the power supply. Never run communication and line voltage wires together. GAS 1) Gas requirements are specified with each unit. (where applicable) 2) Gas lines must follow guidelines and code requirements for your location. 3) Ventilation and combustion air needs are different for each unit. Please take time to check all proposed heater locations with your gas company or gas fitter to insure adequate combustion air and ventilation.PLUMBING 1) Pipe materials for all pool recirculation and therapy lines to be schedule 40 PVC(ASTM D1785). PVC pipng shall be stamped with N.S.F. seal of approval. All plumbing fittings and pipe must be pressure rated. 2) Prior to connection to spa, all underground plumbing must be pressurized and maintain pressure for 24 hours minimum. 3) All plumbing stub-out locations will be labeled on drawing. Confirm location if applicable. 4) Never handle or lift tub by plumbing. It is the responsibility of the client to make sure that all products are in compliance with local codes andregulations. Certain jurisdictions may require additional testing and/or listing. It is also the responsibilityof the client to arrange and pay for any permits, permit fees, inspections and inspection fees.Consult your local governmental agencies for additional information. Diamond Spas, Inc reserves the right to change , amend and/or modify all or any part of the fabrication including but not limited to vessel and/or equipment design, layout and/or components, at any timewithout notice. Approval of this drawing is acknowledgement of this notice and is legally binding. GENERAL INSTALLATION GUIDELINES Stainless steel and copper can become hot if left in direct sunlight for extended periods of time. DSI recommends undermounting all outdoor spas. NEVER LEAVE THE SPA UN-COVERED WHILE EMPTY excessive heat can build up on the spa if it is not full of water. A solid or opaque covering will suffice. Heat damage is not covered under your warranty. NEVER LEAVE CHILDREN UNATTENDED AROUND SPA 1) Spa must sit on a smooth, flat, level concrete pad. Pad should be a minimum of 4" thick an or as per the structural engineer. 2) The area under the hot tub unit and the equipment must have a waterproof pan or membrane that goes into a drain to prevent flooding or water damage to the region below. 3) Certain applications may use plywood decking and or other material for tub support. 4) PVC and conduit requirements are specified for each tub. Make sure that all underground lines are pressure tested prior to and during back fill. 5) DSI will specify the necessary space requirements for remote location equipment rooms. Equipment rooms are to be no more than 50' from the spa unless previously discussed with DSI. The room is recommended to be at or below the same elevation of the spa. 6) DSI recommends a floor drain in the spa vault and the equipment room vault. 7) Once you have the tub placed and level, connect all water, air and communication lines. All plumbing and communication lines are clearly labeled at the stub out location spa side as well as on the equipment package. DSI recommends that you fill and test the spa at this time to verify proper connection of all water, air and communication lines. 8) Upon inspection of all plumbing and conduits, you may now build the remaining retaining vault wall. Take appropriate precaution that the lines are not disturbed during back fill. 9) It is the responsibility of the owner/user to provide clear and easy access on all sides of the spa for repair. Otherwise, all additional costs to service and repair the spa will not be incurred by DSI. Inspection ports and/or service access is very important, please take this recommendation into consideration. If you have any questions and or need design ideas please call Diamond Spas. STAINLESS STEEL CARE 1) Stainless steel is highly resistant to rust and corrosion. Stainless steel is extremely durable and with proper care and maintenance will maintain it's luster and appearance indefinitely. 2) DSI uses 316L or 304L grade stainless. Each unit has a random hand finish applied to it as all product is hand crafted, exhibiting a visible concise weld seam. 3) DSI recommends rinsing any exposed stainless steel with fresh water on a a regular basis to remove any salt air or pollution contaminate. 4) Minor build up and/or spotting is simply removed with regular care and a "Scotch-Brite" scouring pad. 5) NEVER use steel wool or steel brushes on a DSI product. These products are carbon steel and leave particles that will rust and create stains. 6) If you should notice any staining and/or discoloration on the stainless steel surface it must be removed immediately. Most discoloration and staining is removed with the "Scotch-Brite" scouring pad. After the area is cleaned rinse with fresh water and dry with a a soft cloth. 7) If you have any questions, please contact DSI at 1-800-951-7727 COPPER CARE 1) DSI uses CR110 copper sheets to fabricate all units. All products are custom fabricated and TIG welded by hand. Each product has a hand buffed finish and patina applied to it. 2) Recommended cleaning is a mild detergent and a soft cloth. Wipe after each and every use to avoid water spotting. 3) Unless otherwise specified, DSI does apply a patina and wax after fabrication. This wax does not offer a permanent seal to the copper and only aids in excessive spotting. The copper will continue to spot and react to it's envirionment. Copper is referred to as the "living metal" and in this unsealed state has excellent antimicrobial properties. The wax will need to be reapplied as a maintenance issue. How often it will have to be reapplied depends on severaly factors such as usage, type of water, etc. DSI can also leave the product in its raw copper state upon request. 4) Environment will affect the patina process. Factors such as humidity, heat and water quality will determine what color your copper will turn. 5) Copper has the ability to change many colors such as pink, brown, blue, green etc. We are unable to tell you the exact color your product will change - it simply depends on the environment the product is exposed to. 6) Although rare, the possibility does exist that a deep patina finish may cause color change to parts of the body that come into contact with the bathing surface. To reduce the chance of this occurring, simply clean the bath with a copper cleaner. 7) If you have any questions, please contact DSI at 1-800-951-7727 RESIDENTIAL Water Specification Note 1) Refer to "Water Care Instructions" document for acceptable mineral levels 2) Do not use water supplied from a water softener 3) Do not add salt 4) Do not use Chlorine or Bromine 5) Do not use Ozone generators 6) Use only Hydrogen Peroxide as an oxidizor and UV for sanitation 12/16/2022 96.00 144.00 120.00 36.00 16.00 TYP 51.95 42.95 21.50 18.00 RECOMMENDED VAULT DIMENSION FOR FUTURE MAINTENANCE 8.00 72.00 16.00 93.00 26.68 75.00 42.00 ADEQUATE DRAINAGE IS REQUIRED IF VESSEL IS TO BE INSTALLED BELOW GRADE. FRAME MUST BE IN A DRY ENVIRONMENT. SPA FRAME MUST BE IN COMPLETE CONTACT WITH A FLAT AND LEVEL STRUCTURAL SURFACE. INSTALLATION SURFACE TO MAINTAIN FLATNESS OF +/- 0.125". ANY GAP LARGER THAN 0.25" BETWEEN THE FRAME AND SURFACE MUST BE SHIMMED. CONTACT DSI FOR SHIMMING INSTRUCTIONS. 2.00 RIGGING ON CORNERS SHEET OF DRAWN CHECKED UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES. DO NOT SCALE DRAWING MATERIAL FINISH Rotary Hand Brushed THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF DIAMOND SPAS INC. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF DIAMOND SPAS INC. IS PROHIBITED. 4409 Coriolis WayFrederick, CO 80504ph. 720-864-9115 1-800-951-SPASfax. 1-866-605-2358 CR 8/15/2022CS 8/15/2022 2 6 304 / 316 L STAINLESS STEEL REVISION B HYDROSPA 4557 - BLEEKER NOTES: - due to the custom nature and welding processes involved in fabrication, there may be some distortion or warpingof the flat surfaces on our products. - all inside weld seams will be visible. - spa will be insulated with a 2-part polyurethane foam. - standard foam, snap-lock cover to be supplied w/ spa. SPA DATA - SPA SURFACE AREA = 40.9 SQ. FT. - SPA CAPACITY = 544 GALLONS - SPA WATER WEIGHT = 4,541 LBS. - SPA SHELL WEIGHT = 1,686 LBS. - SPA TOTAL WEIGHT = 6,227 LBS. DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL 1/4" TWO PLACE DECIMAL 0.25" 12/16/2022 A A B B CC DD 24.00 14.00 38.00 6.00 OPERATIONAL WATER LEVEL 18.00 32.00 SECTION A-A SECTION B-BSECTION C-C SECTION D-D SHEET OF DRAWN CHECKED UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES. DO NOT SCALE DRAWING MATERIAL FINISH Rotary Hand Brushed THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF DIAMOND SPAS INC. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF DIAMOND SPAS INC. IS PROHIBITED. 4409 Coriolis WayFrederick, CO 80504ph. 720-864-9115 1-800-951-SPASfax. 1-866-605-2358 CR 8/15/2022CS 8/15/2022 3 6 304 / 316 L STAINLESS STEEL REVISION B HYDROSPA 4557 - BLEEKER 12/16/2022 E E -1.5" FNPT DRAIN FITTING BELOW AUTOCOVER DRIVE MOTOR -CONNECTION TO WASTEWATER BY OTHER AUTOFILL SENSOR TOPSIDE: -MOUNTED REMOTELY BY OTHERS -DSI TO PROVIDE 25FT OF CABLE AUTO COVER: -KEYPAD INSTALLED REMOTELY BY OTHERS, NO MORE THAN 15 FEET FROM AUTOCOVER & WITHIN EYESIGHT -REQUIRES 115V 10 A GFCI SERVICE AT KEYPAD 3 2 14 15 12 1 9 11 3X 11 11 2X 10 82X 113X 11 82X 13 11 2X 9 1067 5X 5 44 16 18.00 26.00 VIEW E-E NOTES: - PLUMBING: - (2X) 3" PVC - SUCTION - (1X) 2" PVC - SKIMMER SUCTION - (1X) 2.50" PVC - JET RETURN - (1X) 2" PVC - CIRCULATION RETURN - (1X) 1" CONDUIT - COMMUNICATION AND SPA LIGHT POWER - SPA SHELL TO BE BONDED WITH MIN. 6 GA BARE COPPER CONDUCTER - SPA LIGHT POWER REQUIRES MIN. 14 GA WIRE ST U B O U T L O C A T I O N ITEM NO.QTY.EQUIPMENT DESCRIPTION 1 1 12GA & 14GA SS SPA SHELL W/3X2X.125" TUBE STEEL FRAME 2 1 autocover - CoverStar - CS300 - LH automatic electric safety cover 3 1 AUTOCOVER STATIC SPOOL AUTOCOVER STATIC SPOOL 4 2 AUTOCOVER RAIL 5 1 AUTOCOVER LEADING EDGE 6 1 AUTOCOVER SPOOL 7 5 AUTOCOVER - LID SUPPORT 8 4 Balboa Suction - 5 Inch - #39152 Balboa - VGB rated 256gpm - 2008 ASME Certified - 5" Suction 9 2 1.5" WALL FITTING, WATERWAY PN 400-9151, 213-9341,219-9191 BLACK WALL FITTING WITH NUT, GASKET, AND DIRECTIONAL EYEBALL (BLACK) 10 2 light - Waterway - 3.5 inch - #630-6005 // 3-1/2" face - front access - RGB LED w/ preset lighting patterns - 12volt -low voltage connection to control #410117-60-0-TLA, CONN, ASSY JUMPER, DAISY-LINK, 60",OVERMOLD (Qty.2) // #701570-14-DLSO-TLA, PCBA, 14 LED, RGB, SPA LIGHT, DAISY LINK W/ STANDOFF,OVERMOLD (Qty.1) 11 12 WATERWAY MINI STORM JET(BLACK) PNs: 228-0379 CPVC, 229-7921 JET - WATERWAY - MINI STORM THREAD 12 1 skimmer - Waterway - front access - 510-1501 square spa skimmer - 1-1/2" S / 2" spigot - flow control with trim plate 13 1 RGB LIGHT BALLAST 701678-DLO-TLA, SPA LED CONTROL-40, 2 POS, DAISY-LINK, OVERMOLD 14 1 TOPSIDE CONTROL - BALBOA - SPA TOUCH 2T SPA TOUCH 2T - #57179 15 1 AUTOCOVER - COVERSTAR - KEYPAD NUMERIC KEYPAD COVER CONTROL 16 1 AQUAFUZION DMS 2.0 SHEET OF DRAWN CHECKED UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES. DO NOT SCALE DRAWING MATERIAL FINISH Rotary Hand Brushed THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF DIAMOND SPAS INC. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF DIAMOND SPAS INC. IS PROHIBITED. 4409 Coriolis WayFrederick, CO 80504ph. 720-864-9115 1-800-951-SPASfax. 1-866-605-2358 CR 8/15/2022CS 8/15/2022 4 6 304 / 316 L STAINLESS STEEL REVISION B HYDROSPA 4557 - BLEEKER 12/16/2022 96.00 30.00 CLEARANCE REQUIRED FOR FILTER SERVICE 43 6 5 7 8 9 1 2 11 12 10 18.00 54.00 DSI TO SHIP ALL EQUIPMENT SEPARATE. EQUIPMENT TO BE INSTALLED IN CLOSET ON SITE BY OTHER. CLOSET DIMENSIONS AS SHOWN. ALL SUPPORTS/SHELVES SUPPLIED AND INSTALLED BY OTHER. NOTES: - SPA REQUIRES (1X)230V 40A GFCI SERVICE @ HYDROQUIP FOR CONTROL. - SPA REQUIRES (1X)230V 60A GFCI SERVICE @ HYDROQUIP FOR HEATER. - SPA REQUIRES (1X)115V 10A GFCI SERVICE @ AUTOCOVER KEYPAD. - AUTOFILL REQUIRES 1/2" FRESH WATER LINE WITH BACKFLOW AND FREEZE PROTECTION LOCATED AT EQUIPMENT - SPA SHELL AND ALL EQUIPMENT TO BE BONDED W/ MIN. #6AWG BARE COPPER CONDUCTOR.* MUST HAVE ACCESS AROUND ENTIRE PERIMETER OF AUTOCOVER BOX FOR FUTURE SERVICE NEEDS EQUIPMENT MUST BE LOCATED IN AN ENCLOSED VENTILATED AREA, PROTECTED FROM WEATHEREQUIPMENT MUST BE LOCATED WITHIN 30 FT OF SPA AND AT OR BELOW WATER LEVELCONTACT DSI IF PLUMING RUN REQUIRES MORE THAN THREE 90 DEG TURNS - 6" FREE FROM FLAMABLE MATERIALS MUST BE MAINTAINEDAROUND GAS HEATER - DIRECT AIR INTAKE DUCT KIT AND FLUE COLLAR ADAPTER PROVIDED BY DSI - REFER TO MANUFACTURER INSTRUCTIONS AND LOCAL CODES FOR AIR INTAKE AND VENT INSTALLATION - GAS HEATER CONFIGURED FOR NATURAL GAS OPERATION EQUIPMENT LOCATION: - EQUIPMENT TO BE WITHIN 10 FT OF SPA WITH AN ELEVATION CHANGE OF -10 FT - INSTALLER TO VERIFY EQUIPMENT LOCATION ITEM NO.QTY.EQUIPMENT DESCRIPTION VOLTAGE HP / Amp NOTES 1 1 pump - Waterway - Executive 56 - 4hp - 372162A-13 2-speed centrifugal pump and motor, 4 h.p., 130gpm @ 60 ft.TDH, 2 1/2" suction, 2" discharge 230 volt 4 h.p.- 4.4 amp / 12 amp 230V connection to control 2 1 pump - Waterway - Executive 56 - 2hp - 3720821-13 2 speed Centrifugal pump and motor, 2 h.p., 63gpm @ 60 ft.TDH, 2-1/2" suction, 2" discharge 230 volt 2 h.p. - 8 amp/3 amp 230V connection to control 3 1 filter - Waterway - 100 sq/ft cartridge - 502-9910 100 sq.ft. cartridge filter w/ 1 gpm/sq.ft. filtration rate, mechanical bypass requires 54" vertical height to service/replace cartridge filter 4 1 HYDROQUIP REMOTE HEATER SYSTEM 11KW, OUTDOOR RATED HYDROQUIP P/N CS8800A 240V REQUIRES (1X) 50A GFCI BREAKER AND (1X) 50A GFCI BREAKER 2" UNIONS 5 1 AQUA UV STERILIZER PN A00507 25W UV sterilizer, 20gpm max flow rate, 2" union 120/240 < 1 amp 6 1 AUTO FILL LEVELOR K1100 auto-fill control - input from sensor - 24VAC output to 1" solenoid valve 115/230 volt 1/.5 amp 115V connection to control. requires 1/2" backflow protected and freeze protected water line. ***DO NOT CONNECT TO WATER SOFTENED LINE*** 7 1 MODEL NO. FLOVIS FV-C 2", NFS 50 APPROVED H2FLOW FLOVIS FLOW METER PN: FV-C 8 1 3 WAY JANDY VALVE W/ MANUAL VALVE LEVER 3WAY JANDY VALVE; 2.5" OUTSIDE 2" INSIDE PN: 4717 9 1 3 WAY JANDY VALVE W/ MANUAL VALVE LEVER 3WAY JANDY VALVE; 3" OUTSIDE 2.5" INSIDE PN: 4719 10 1 UV - CLEAR COMFORT FRAME CLEAR COMFORT SHEET METAL FRAME 11 1 1 GALLON PEROXIDE 1 GALLON CHEMICAL JUG 12 1 chemical pump - Stenner - Peristaltic Pump #E10T1F 3-point roller peristaltic chemical pump -- 1/4" OUTLET 120 volt 60 Hz , 240volt 50 Hz .17 AMP 25 psi max operating pressure, 3 oz per hour, Programmable pump with automatic dosing control for timed applications SHEET OF DRAWN CHECKED UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES. DO NOT SCALE DRAWING MATERIAL FINISH Rotary Hand Brushed THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF DIAMOND SPAS INC. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF DIAMOND SPAS INC. IS PROHIBITED. 4409 Coriolis WayFrederick, CO 80504ph. 720-864-9115 1-800-951-SPASfax. 1-866-605-2358 CR 8/15/2022CS 8/15/2022 5 6 304 / 316 L STAINLESS STEEL REVISION B HYDROSPA 4557 - BLEEKER 12/16/2022 104.40 34.80 TYP 82.00 83.90 84.52 76.0° 104.0° FO L D VE L C R O 4.00 2.00 2.00 SLOPE NO SKIRT SHEET OF DRAWN CHECKED UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES. DO NOT SCALE DRAWING MATERIAL FINISH Rotary Hand Brushed THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF DIAMOND SPAS INC. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF DIAMOND SPAS INC. IS PROHIBITED. 4409 Coriolis WayFrederick, CO 80504ph. 720-864-9115 1-800-951-SPASfax. 1-866-605-2358 CR 8/15/2022CS 8/15/2022 6 6 304 / 316 L STAINLESS STEEL REVISION B HYDROSPA 4557 - BLEEKER SHEET OF DRAWN CHECKED UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES. DO NOT SCALE DRAWING MATERIAL FINISH Rotary Hand Brushed THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF DIAMOND SPAS INC. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF DIAMOND SPAS INC. IS PROHIBITED. 4409 Coriolis WayFrederick, CO 80504ph. 720-864-9115 1-800-951-SPASfax. 1-866-605-2358 CR 8/15/2022CS 8/15/2022 6 6 304 / 316 L STAINLESS STEEL REVISION B HYDROSPA 4557 - BLEEKER FLOATING FOAM COVER *FLOATING COVERS DO NOT MEET SAFETY BARRIER REQUIREMENTS* NOTES: *PROJECTS WILL NOT BE SCHEDULED UNTIL COVER COLOR IS SELECTED* COVER MANUFACTURER MAINTAINS A -1.0" TOLERANCE ON OVERALL COVER DIMENSIONS *IF COVER COLOR IS NOT SELECTED AT TIME OF APPROVAL DEFAULT COVER COLORS WILL BE PROVIDED* NOTES: “10” adjustable strap locations are determined by cover manufacturer unless otherwise noted by client - Includes a minimum of 8 evenly distributed straps. Spa covers must be strapped down to a flat, level surface. Locking cover strap buckles will be provided and must be installed on site for ASTM compliance. Covers that exceed 108” in length will not be warrantied by the manufacturer against sagging, puddling, buckling or breakage” *IF COVER COLOR IS NOT SELECTED AT TIME OF APPROVAL DEFAULT COVER COLORS WILL BE PROVIDED* COVER MANUFACTURER MAINTAINS A +1.0" TOLERANCE ON OVERALL COVER DIMENSIONS 12/16/2022