Loading...
HomeMy WebLinkAboutFile Documents.105 W Hyman Ave.0108-2022-BRES (8) MXZ-3C3ONAHZ3 )MITSUBISHI 2.5-TON MULTI-ZONE INVERTER HEAT-PUMP SYSTEM Ep—•ELEC7RICNG Job Name: System Reference: Date: Al Illllllllllllllllllmi,, 14 IIdiIIIIIIIIIIIIIIIIhIIIIIIIIIIIIIIIIIIIIIIkL. .1111111111111111111111111111111111C11111 . 1IIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIimiddIIIIIIIP'1 '9I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I U!!!III' "111111lllllllllll111Pll r FEATURES • Variable speed INVETER-driven compressor • Built-in base pan heater • Quiet outdoor unit operation as low as 54 dB(A) • High pressure protection • Compressor thermal protection • Compressor overcurrent detection • Fan motor overheating/voltage protection • Hyper-heating performance offers 100%heating capacity at 5°F and 88%heating capacity at-13°F • ENERGY STAR®certified(non-ducted) RECEIVED 02/09/2023 ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. n p� Specifications are subject to change without notice. ©2022 Mitsubishi Electric Trane HVAC US LLC!A*Pl gMd i�served. BUILDING DEPARTMENT SPECIFICATIONS: MXZ-3C3ONAHZ3 Maximum Capacity BTU/H 23,600//23,600//23,600 Rated Capacity BTU/H 28,400//27,800//27,400 Cooling'(Non-Ducted//Mix//Ducted) Minimum Capacity BTU/H 12,600//12,600//12,600 Maximum Power Input W 3,770//3,770//3,770 Rated Power Input W 2,272//2,467//2,661 Power Factor(208V,230V) % 98.7,98.7//98.7,98.7//98.7,98.7 Maximum Capacity BTU/H 36,000//30,600//30,600 Rated Capacity BTU/H 28,600//28,000//27,600 Heating at 47°P(Non-Ducted//Mix// Minimum Capacity BTU/H 11,400//11,400//11,400 Ducted) Maximum Power Input W 4,540//4,540//4,540 Rated Power Input W 2,096//2,142//2,187 Power Factor(208V,230V) % 97.8,97.8//97.9,97.9//97.9,97.9 Maximum Capacity BTU/H 28,600//28,100//27,600 Heating at 17°F'(Non-Ducted//Mix// Rated Capacity BTU/H 18,000//17,750//16,500 Ducted) Maximum Power Input W 4,192//4,223//4,258 Rated Power Input W 1,990//1,992//1,993 Heating at 5°F°(Non-Ducted//Mix// Maximum Capacity BTU/H 28,600//28,100//27,600 Ducted) Maximum Power Input W 4,290//4,495//4,700 SEER 18.0//17.0//16.0 EER' 12.5//11.4//10.3 HSPF(IV) 11.0//10.4//9.8 Efficiency(Non-Ducted//Mix//Ducted) COP at 47°F' 4.0//3.85//3.7 COP at 17°F at Maximum Capacity' 2.0//1.95//1.9 COP at 5°F at Maximum Capacity' 1.95//1.91//1.72 ENERGY STAR®Certified Yes//No//No Electrical Power Requirements Voltage,Phase, 208/230,1,60 Frequency Guaranteed Voltage Range VAC 187-253 Voltage:Indoor-Outdoor,S1-S2 VAC 208/230 Voltage:Indoor-Outdoor,S2-S3 V DC 24 Electrical Short-circuit Current Rating(SCCR) kA 5 Recommended Fuse/Breaker Size A 40 Recommended Wire Size AWG 14 Minimum Circuit Ampacity A 30.5 Maximum Overcurrent Protection A 40 Fan Motor Full Load Amperage A 2.43 Airflow Rate(Cooling/Heating) CFM 2,224/2,550 Refrigerant Control LEV Defrost Method Reverse Cycle Heat Exchanger Type Plate fin coil Sound Pressure Level,Cooling' 54 Sound Pressure Level,Heating' 58 Compressor Type DC INVERTER-driven Twin Rotary Compressor Model MNB33FBTMC-L Compressor Rated Load Amps A 20 Outdoor unit Compressor Locked Rotor Amps A 28.8 Compressor Oil Type//Charge oz. FV5OS//37.2 Base Pan Heater Built-in W:In.[mm] 37-13/32[950] Unit Dimensions D:In.[mm] 13[330] H:In.[mm] 41-17/64[1,048] W:In.[mm] 41-3/8[1,050] Package Dimensions D:In.[mm] 17-3/8[440] H:In.[mm] 46-3/4[1,190] Unit Weight Lbs.[kg] 189[86] Package Weight Lbs.[kg] 213[97] Cooling Intake Air Temp(Maximum/Minimum'") TDB 115/14 Outdoor unit operating temperature Cooling Thermal Lock-out/Re-start Temperatures °FDB 10.4/14 range Heating Intake Air Temp(Maximum/Minimum) °FWB 65/-13 Heating Thermal Lock-out/Re-start Temperatures TDB -18/-14 Charge Lbs,oz 8.0,13.0 Refrigerant Chargeless Piping Length Ft.[m] 98.0[30.0] Additional Refrigerant Charge Per Additional Piping Length oz./Ft.[g/m] 0.216[20] NOTES: AHRI Rated Conditions 'Cooling(Indoor//Outdoor) °F 80 DB,67 WB//95 DB,75 WB (Rated data is determined at a fixed compressor speed) 'Heating at 47°F(Indoor//Outdoor) °F 70 DB,60 WB//47 DB,43 WB 'Heating at 17°F(Indoor//Outdoor) °F 70 DB,60 WB//17 DB,15 WB Conditions °Heating at 5°F(Indoor//Outdoor) °F 70 DB,60 WB//5 DB,4 WB 'Applications should be restricted to comfort cooling only;equipment cooling applications are not recommended for low ambient temperature conditions. 'A 5°F DB-115°F DB when optional wind baffles are installed FAltr hough actual capacity um performanceontbasedlea oa indoor is 1 unit type andornumber itaof indoort units connected,retha please refer to Md Operationall tfor this o � Although the maximum connectable capacity is 130%,the outdoor unit cannot provide more than 100%of the rated capacity.Please utilize this over capacity capability for lea r a where it is known that all connected units will NOT be operating at the same time. oft 02/n0�9p/2� 023 Specifications are subject to change without notice. ©2022 Mitsubishi Electric Trane HVAC US LLC!AiNi F i�served. BUILDING DEPARTMENT SPECIFICATIONS: MXZ-3C3ONAHZ3 Maximum Number of Connected IDU 3 Indoor unit connection Minimum Number of Connected IDU 2 Minimum connected capacity BTU/H 12,000 Maximum connected capacity BTU/H 36,000 Liquid Pipe Size O.D.(Flared) In.[mm] A,B,C:1/4[A,B,C:6.35] Gas Pipe Size O.D.(Flared) In.Imm] A:1/2;B,C:3/8[A:12.72;B,C:9.52] Total Piping Length Ft.[m] 230[70] Piping Maximum Height Difference,ODU above IDU Ft.[m] 49[15] Maximum Height Difference,ODU below IDU Ft.[m] 49[15] Farthest Piping Length from ODU to IDU Ft.[m] 82[25] Maximum Number of Bends for IDU 70 NOTES: AHRI Rated Conditions 'Cooling(Indoor//Outdoor) °F 80 DB,67 WB//95 DB,75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F(Indoor//Outdoor) °F 70 DB,60 WB//47 DB,43 WB 'Heating at 17°F(Indoor//Outdoor) °F 70 DB,60 WB//17 DB,15 WB Conditions °Heating at 5°F(Indoor//Outdoor) °F 70 DB,60 WB//5 DB,4 WB 'Applications should be restricted to comfort cooling only;equipment cooling applications are not recommended for low ambient temperature conditions. '5°F DB-115°F DB when optional wind baffes are installed For actual capacity performance based on indoor unit type and number of indoor units connected,please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130%,the outdoor unit cannot provide more than 100%of the rated capacity.Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. RECEIVED 02/n09p/�2� 023 Specifications are subject to change without notice. ©2022 Mitsubishi Electric Trane HVAC US LLCfASi gktd f�served. BUILDING DEPARTMENT OUTDOOR UNIT ACCESSORIES: MXZ-3C3ONAHZ3 Air Outlet Guide Air Outlet Guide(1 Piece) 0 PAC-SH96SG-E Refrigeration Ball Valve-1/2" 0 BV12FFSI2 Refrigeration Ball Valve-1/4" ❑ BV14FFSI2 Ball Valve Refrigeration Ball Valve-3/8" ❑ BV38FFSI2 Refrigeration Ball Valve-5/8" ❑ BV58FFSI2 Drain Socket Drain Socket 0 PAC-SG6ODS-E Hail Guards Hail Guard _ 0 HG-Al M-NET Converter M-NET Converter 0 PAC-IF01 MNT-E Condensing Unit Mounting Pad:16"x 36"x 3" 0 ULTRILITE1 Mounting Pad Outdoor Unit 3-1/4 inch Mounting Base(Pair)-Plastic 0 DSD-400P Adaptor:1/2"x 3/8" ❑ MAC-A455JP-E Adaptor:1/2"x 5/8" 0 MAC-A456JP-E Port Adapter Adaptor:3/8"x 1/2" 0 MAC-A454JP-E Adaptor:3/8"x 5/8" 0 PAC-SG76RJ-E 18"Single Fan Stand 0 QSMS1801 M 24"Single Fan Stand 0 QSMS2401 M Stand Condenser Wall Bracket 0 QSWB2000M-1 Condenser Wall Bracket-Stainless Steel Finish 0 QSWBSS Outdoor Unit Stand—12"High 0 QSMS1201 M RECEIVED 02/n09p/�2� 023 Specifications are subject to change without notice. ©2022 Mitsubishi Electric Trane HVAC US LLC!ASi gktd i�served. BUILDING DEPARTMENT OUTDOOR UNIT DIMENSIONS: MXZ-3C3ONAHZ3 Unit: inch (mm) 6-7/8' 23-5/8' 6-7/8' III Rear Air Intake 2-13/16" 27/32" 2-1/32" 111 IIII 4-19/c 2-U Shaped Notched Hole (Foundation Bolt M10) 13/32" ll ME 0 15 'mom I O m Side Air Intake 1 n 6-91-5/16'Draiivu n Hole tl�l1li it 01-3/32'punched hole I13/32`• Air w 113/32" (Connecting wire hale) Discharge 2-87/8"punched hole 2-(15/32"x1-13/32")Oval Hole 2-15/16" (Connecting wire hole) (Foundation Bolt M10) 2-3/32"• 3-87/8"knockout hole 1-5/32"11111 (Connecting wire hole) E 37-13/32" 31/32" 13' 19/32" l"r�_, . A I IIF1iL O® � III j® / �I� i- 1 l� Handle ��11 Handle �� ( Handle y- �i IC_ \j�� lr I Handle Air Intake Lo ,,, lin"j'l I — � . I, � ® ill • ` I4 Iw l� jE7g �� I �® ■ ,�I " � pliElE1 � III i1 tll Init /4'(06.351FLARENrowi' �;\\ /i III :=2:4::}14: l J}GAS 3/8'(49.521FLARE •• iiii lnitB!I■{III LIO /4'106.351FLARE�iuLJI____________ m�l Anif Al-GAS2(0R�1 ..A, L v --- - '1-5/16" 14-7/32" 1.FREE SPACE Q E N Lock nut Conduit plate Top o 3-15/16' or more Conduit connector m I e 3-15/16" or more 13-25/32" or more ... W / ` " G� ---'-- _ 2.SERVICE SPACEom 1► 1 o IQ„1, (It E • • Conduit plate Under S� 3-15/16' or more SERVICE SPACE 13-25/32' or more 13-25/32' or more 1340 Satellite Boulevard Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com .+nnli CEI 1E CED c us FORM#MXZ-3C30NAHZ3-202206 lif I /0§71023 Specifications are subject to change without notice. ©2022 Mitsubishi Electric Trane HVAC US LLC!AiNigktd ieserved. BUILDING DEPARTMENT