Loading...
HomeMy WebLinkAboutFile Documents.617 W Bleeker St.0052-2022-BCHO (11)P.O. Box 944, Glenwood Springs, CO 81602 Info@Young-Services.com (970)384-2271 FAX: (970) 384-2722 Heat Exchanger Back to Top 12/16/2022 Superior Design TTP brazed plate heat exchangers consist of as many as 150 pattern-embossed stainless steel plates. The plates are brazed together, with every second plate turned 180º to create two separate flow channels with two mediums in counter current. The design of the plates creates a high turbulence resulting in an outstanding heat transfer.The result is a highly efficient heat exchanger that utilizes all the material in the heat transfer process. Customer Support and Service When you choose a TTP heat exchanger, you gain access to the TTP software package - a sophisticated computer program that will select the optimum heat exchanger for your particular application. Non Corrosive The plates are made of stainless, acid-resistant steel, with 99.9% pure copper and brazed, which ensures a very high resistance to corrosion. Self Cleaning The TTPheat exchanger operates with a turbulent flow, even at low velocities, creating a self clean- ing, self descaling design that resists scaling. Domestic Hot Water, Snow melting, Hydro Air, Radiant floor,... HX-1: Qty 1 - Snowmelt 12/16/2022 TTP1-14E* TTP1-20E* TTP1-30E* TTP3-14 TTP3-20 TTP3-40 TTP4-14 TTP4-24 TTP4-30 TTP4-50 TTP7-20 TTP7-24 TTP7-30 TTP7-40 TTP7-50 TTP7-60 3/4 2.88 2.88 2.88 8.0 1.6 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 2.5 2.5 2.5 2.5 2.5 2.5 3.85 3.00 5.00 4.50 5.25 7.80 7.20 9.75 11.30 16.50 38.50 44.00 52.00 65.00 78.00 92.00 2.1 3.0 1.6 2.1 3.9 1.6 2.5 3.0 4.8 2.1 2.5 3.0 3.9 4.8 5.7 8.0 8.0 6.5 6.56 1.63 1.63 1.63 2.88 2.88 2.88 2.88 2.88 2.88 2.88 7.88 7.88 7.88 7.88 7.88 7.88 6.56 6.56 4.75 4.75 4.75 11.00 11.00 11.00 11.00 18.13 18.13 18.13 18.13 18.13 18.13 6.5 6.5 12.8 12.8 12.8 12.8 20.63 20.63 20.63 20.63 20.63 20.63 4.66 4.66 4.66 4.66 4.66 4.66 4.66 10.34 10.34 10.34 10.34 10.34 10.34 3/4 3/4 1 1 1 1 1 1 1 2 2 2 2 2 2 Threaded Connections (inch) NPT Model A B C D E F Empty Weight lbs Dimensions (inch) Materials Plates and connections: AISI 316 Stainless Steel Solder: Copper 99.9% Operating Conditions Max. working pressure: 450psig - Max. working temperature: 365ºF Approvals Insulation Each unit (except TTP-1) can be insulated. Specifications available upon request. Specifications For double wall application, contact Triangle Tube/Phase III®for sizing assistance. Double Wall (Underwriters Laboratory) *Economic version - maximum working pressure: 150 psig D C B A E F For extra protection against leakage a special double wall system is avail- able. The heat exchanger consists of two stainless steel plates instead of one, which significantly reduces the chance of fluid contamination. 12/16/2022 TTP1-14E TTP1-14E TTP1-14E TTP1-14E TTP1-14E TTP1-20E TTP1-20E TTP1-30E TTP1-30E TTP1-30E TTP3-20 TTP3-40 TTP3-40 TTP3-40 TTP3-40 TTP3-40 TTP3-40 TTP3-40 TTP3-40 TTP3-40 TTP7L-24 TTP7M-40 25,000 2.7 0.7 1.7 0.2 0.3 0.5 0.6 0.8 0.6 0.8 0.7 0.9 1.2 0.7 0.3 0.4 0.6 0.7 0.9 1.1 1.4 1.6 2.2 1.3 1.5 1.8 2.1 2.4 2.8 3.1 3.5 4.2 4.9 5.6 6.3 7.0 8.7 10.4 12.2 13.9 15.7 17.4 19.2 20.9 24.4 27.9 31.3 34.8 1.0 1.4 1.8 2.3 1.4 2.0 1.6 2.1 2.6 1.9 0.6 0.8 1.1 1.5 1.9 2.3 2.8 3.4 4.6 4.0 3.9 4.9 3.1 3.6 4.1 4.6 5.1 6.1 7.2 8.2 9.2 10.2 12.8 15.4 18.0 20.5 23.0 25.6 28.2 30.7 35.8 40.1 46.1 51.2 30,000 35,000 40,000 45,000 50,000 60,000 70,000 80,000 90,000 100,000 125,000 150,000 175,000 200,000 225,000 250,000 275,000 300,000 350,000 400,000 450,000 500,000TTP7M-40 Btu/Hr SuppliedModel Boiler GPM Pressure Drop PSI Boiler Snow Melt GPM Pressure Drop PSI Snow Melt 30º temp. rise (100º-130º) boiler (180º-160º) 30% glycol on snow melt side TTP1-14E TTP1-14E TTP1-14E TTP1-14E TTP1-14E TTP1-14E TTP1-14E TTP1-14E TTP1-14E TTP1-14E TTP3-20 TTP3-20 TTP3-20 TTP3-20 TTP3-20 TTP3-20 25,000 2.6 0.5 2.5 0.4 0.6 0.9 1.1 1.4 1.7 2.1 2.5 2.9 3.4 1.3 2.1 3.0 4.1 5.5 7.0 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 10.1 12.6 15.2 17.7 20.2 22.7 0.8 1.1 1.4 1.8 2.3 2.8 3.4 4.0 4.6 1.6 2.6 3.8 5.2 6.9 8.8 3.1 3.6 4.1 4.6 5.2 5.7 6.2 6.7 7.2 10.3 12.9 15.5 18.8 20.6 23.6 30,000 35,000 40,000 45,000 50,000 55,000 60,000 65,000 70,000 100,000 125,000 150,000 175,000 200,000 225,000 Btu/Hr Supplied Model Boiler GPM Pressure Drop PSI Boiler Radiant GPM Pressure Drop PSI Radiant 20º temp. rise (100º-120º) boiler (180º-160º) For typical snow melt applications For typical floor heating applications Boiler Air separator TTP heat exchanger Balancing valve Slab circulator Returns Supply other zones Boiler circulator Snow melting slab Example of Snow Melting Application with TTP Heat Exchangers Heating Applications 12/16/2022