HomeMy WebLinkAboutFile Documents.803 E Durant Ave.0128-2022-BRES (6)
Property Address
803 E. Durant Ave. #9
Aspen, CO 81611
Element Environmental Project#:
BG 091922 Durant
Client Job Name
Durant Ave.
TABLE OF CONTENTS
1.0 - Scope of Work
2.0 - Sampling Requirements
3.0 - Sampling Methodology
4.0 - Laboratory
5.0 - Suspect Materials Sampled
6.0 - Table of Results
7.0 - Description of Sampling Area
8.0 - Conclusion
9.0 - Lab Report
10.0 - Certificates
Asbestos Samples Analyzed: 22
Positive Asbestos Samples: 0
________________________________________
AS
B
E
S
T
O
S
L
E
A
D
HA
Z
M
A
T
RE
S
T
O
R
A
T
I
O
N
ww
w
.
e
l
e
m
e
n
t
co
n
s
u
l
t
s
.c
o
m
Asbestos Sampling Report
Date: 09/21/2022
Date of Inspection: 09/19/2022
Client:
BG Architecture & Design
111H AABC
Aspen, CO 81611
Attn:
Barry Gereb
Building Inspector:
James Bates
CDPHE #28136
Joshua Johnson
CDPHE #18401
PO Box 2043
Glenwood Springs, CO 81602
josh@elementconsults.com
(970) 274-3139
11/09/202201/23/2023
sami
Project #-BG 091922 Durant
2
1.0- This was an inspection for suspect ACM (Asbestos Containing Material) for a remodel.
Element Environmental conducted a visible inspection for visible materials that would
be impacted during the remodel. This inspection was limited to the areas found in the
Description of the Sampling Area 7.0. Although sampling is destructive in nature, this
was a non-invasive inspection. It was of materials that were accessible. If other suspect
materials become visible/apparent during demolition or construction activities, work in
that area should be halted and more sampling/testing must take place, per Colorado
regulations. Any suspect materials that were not tested are to be assumed to contain
asbestos.
2.0- A limited bulk sampling of from all suspect materials was conducted in accordance with
Colorado State Requirements. The minimum number of samples per homogenous areas
are as follows:
2.1- Surfacing Materials- <1,000 sq.ft.- Minimum of 3 samples
1,000 sq.ft.- 5,000sq.ft.- Minimum of 5 samples
>5,000 sq.ft. Minimum of 7 samples
2.2- Miscellaneous materials- Minimum of 2 samples
2.3- Thermal Systems Insulation (TSI)- Minimum of 3 samples
3.0- The purpose of the inspection is to identify materials that are homogenous. A
homogeneous area is defined as one which shares suspect material, texture, color,
location, and/or apparent time of construction. The materials are segregated into
separate homogenous areas. The size is determined and then samples are taken. The
materials are touched to determine friability. Friable ACM is material that can be
crushed or reduced to powder by hand pressure. The samples are taken in a random
numerical sequence.
4.0- James Bates, a Colorado Department of Public Health & Environment certified building
inspector, certification number: 28136, performed the inspection. The findings were
reviewed by Josh Johnson, a Colorado Department of Public Health & Environment
certified building inspector, certification number: 18401. Samples taken were sent to
CEI Labs in Cary, North Carolina. The samples were analyzed by PLM (Polarized Light
Microscopy) analysis. Per the CDPHE Regulation any sample that is found by a lab to be
trace, or <1% asbestos, is considered to be ACM material. This material would still be a
regulated material by CDPHE. The sample must have an additional “point count”
performed to be considered less than 1% and not be regulated by the CDPHE. The lab’s
documents with analyses and findings are found below.
11/09/202201/23/2023
sami
Project #-BG 091922 Durant
3
5.0- SUSPECT MATERIALS SAMPLES
• Drywall
• Texture
• Tape
• Joint Compound
• Vinyl Tile and Mastic
• Carpet and Pad
• Ceiling Tile
6.0- TABLE OF RESULTS
HOMOGENOUS
AREA
DESCRIPTION OF AREA ACM CATEGORY NUMBER
OF
SAMPLES
APPROXIMATE
SQ.FT.*
ACM ASSESSMENT CATEGORIES
% AND TYPE OF
ASBESTOS FOUND
(A) Skip Trowel Texture on Ceilings Surfacing
5 ~1,100 sq.ft. Friable Non-ACM No Asbestos Detected
(B) Skip Trowel Texture in Skylights Surfacing 3 ~100 sq.ft. Friable Non-ACM No Asbestos Detected
(C) Drywall System throughout Miscellaneous 2 ~1,200 sq.ft. Friable Non-ACM No Asbestos Detected
(D) Brick Mortar on Fireplace Miscellaneous 2 ~200 sq.ft. Friable Non-ACM No Asbestos Detected
(E) 12 x 12 Vinyl Tile Miscellaneous 2 ~60 sq.ft. Non-Friable Non-ACM No Asbestos Detected
(F) Tile Mastic Miscellaneous 2 ~60 sq.ft. Non-Friable Non-ACM No Asbestos Detected
(G) Ceiling Tile in Closet Miscellaneous 2 ~1,5 sq.ft. Friable Non-ACM No Asbestos Detected
(H) Carpet Miscellaneous 2 ~500 sq.ft. Non-Friable Non-ACM No Asbestos Detected
(I) Carpet Pad Miscellaneous 2 ~500 sq.ft. Non-Friable Non-ACM No Asbestos Detected
Key:
ACM Assessment Categories:
1- Damaged or significantly damaged Thermal Systems Insulation
2- Damaged friable surfacing ACM
4- Damaged or significantly damaged friable Miscellaneous ACM
5- ACM with potential for damage
6- ACM with potential for significant damage
7- Friable ACM with low potential for damage
Other- ACM not classified in the above Assessment Categories
N/A- Not Applicable
* Square footage is estimated and not for bidding purposes
11/09/202201/23/2023
sami
Project #-BG 091922 Durant
4
7.0- DESCRIPTION OF SAMPLING AREA
• Skip Trowel Texture on ceilings and skylights
• Drywall System on ceiling and under paneling
• Mortar on fireplace
• 12 x 12 Tile and Mastic in Kitchen
• Ceiling Tile in closet
• Carpet and Pad
Sampling Locations
N
NTS
11/09/202201/23/2023
sami
Project #-BG 091922 Durant
5
8.0- CONCLUSION
No asbestos was detected in any of the samples taken.
Sincerely,
Josh Johnson
11/09/202201/23/2023
sami
Project #-BG 091922 Durant
6
9.0- LAB REPORT
11/09/202201/23/2023
sami
Project #-BG 091922 Durant
7
11/09/202201/23/2023
sami
Project #-BG 091922 Durant
8
11/09/202201/23/2023
sami
Project #-BG 091922 Durant
9
11/09/202201/23/2023
sami
Project #-BG 091922 Durant
10
11/09/202201/23/2023
sami
Project #-BG 091922 Durant
11
11/09/202201/23/2023
sami
Project #-BG 091922 Durant
12
11/09/202201/23/2023
sami
Project #-BG 091922 Durant
13
11/09/202201/23/2023
sami
Project #-BG 091922 Durant
14
10.0- CERTIFICATES
11/09/202201/23/2023
sami