HomeMy WebLinkAboutFile Documents.803 E Durant Ave.0128-2022-BRES (6) Property Address 803 E. Durant Ave. #9 Aspen, CO 81611 Element Environmental Project#: BG 091922 Durant Client Job Name Durant Ave. TABLE OF CONTENTS 1.0 - Scope of Work 2.0 - Sampling Requirements 3.0 - Sampling Methodology 4.0 - Laboratory 5.0 - Suspect Materials Sampled 6.0 - Table of Results 7.0 - Description of Sampling Area 8.0 - Conclusion 9.0 - Lab Report 10.0 - Certificates Asbestos Samples Analyzed: 22 Positive Asbestos Samples: 0 ________________________________________ AS B E S T O S L E A D HA Z M A T RE S T O R A T I O N ww w . e l e m e n t co n s u l t s .c o m Asbestos Sampling Report Date: 09/21/2022 Date of Inspection: 09/19/2022 Client: BG Architecture & Design 111H AABC Aspen, CO 81611 Attn: Barry Gereb Building Inspector: James Bates CDPHE #28136 Joshua Johnson CDPHE #18401 PO Box 2043 Glenwood Springs, CO 81602 josh@elementconsults.com (970) 274-3139 11/09/202201/23/2023 sami Project #-BG 091922 Durant 2 1.0- This was an inspection for suspect ACM (Asbestos Containing Material) for a remodel. Element Environmental conducted a visible inspection for visible materials that would be impacted during the remodel. This inspection was limited to the areas found in the Description of the Sampling Area 7.0. Although sampling is destructive in nature, this was a non-invasive inspection. It was of materials that were accessible. If other suspect materials become visible/apparent during demolition or construction activities, work in that area should be halted and more sampling/testing must take place, per Colorado regulations. Any suspect materials that were not tested are to be assumed to contain asbestos. 2.0- A limited bulk sampling of from all suspect materials was conducted in accordance with Colorado State Requirements. The minimum number of samples per homogenous areas are as follows: 2.1- Surfacing Materials- <1,000 sq.ft.- Minimum of 3 samples 1,000 sq.ft.- 5,000sq.ft.- Minimum of 5 samples >5,000 sq.ft. Minimum of 7 samples 2.2- Miscellaneous materials- Minimum of 2 samples 2.3- Thermal Systems Insulation (TSI)- Minimum of 3 samples 3.0- The purpose of the inspection is to identify materials that are homogenous. A homogeneous area is defined as one which shares suspect material, texture, color, location, and/or apparent time of construction. The materials are segregated into separate homogenous areas. The size is determined and then samples are taken. The materials are touched to determine friability. Friable ACM is material that can be crushed or reduced to powder by hand pressure. The samples are taken in a random numerical sequence. 4.0- James Bates, a Colorado Department of Public Health & Environment certified building inspector, certification number: 28136, performed the inspection. The findings were reviewed by Josh Johnson, a Colorado Department of Public Health & Environment certified building inspector, certification number: 18401. Samples taken were sent to CEI Labs in Cary, North Carolina. The samples were analyzed by PLM (Polarized Light Microscopy) analysis. Per the CDPHE Regulation any sample that is found by a lab to be trace, or <1% asbestos, is considered to be ACM material. This material would still be a regulated material by CDPHE. The sample must have an additional “point count” performed to be considered less than 1% and not be regulated by the CDPHE. The lab’s documents with analyses and findings are found below. 11/09/202201/23/2023 sami Project #-BG 091922 Durant 3 5.0- SUSPECT MATERIALS SAMPLES • Drywall • Texture • Tape • Joint Compound • Vinyl Tile and Mastic • Carpet and Pad • Ceiling Tile 6.0- TABLE OF RESULTS HOMOGENOUS AREA DESCRIPTION OF AREA ACM CATEGORY NUMBER OF SAMPLES APPROXIMATE SQ.FT.* ACM ASSESSMENT CATEGORIES % AND TYPE OF ASBESTOS FOUND (A) Skip Trowel Texture on Ceilings Surfacing 5 ~1,100 sq.ft. Friable Non-ACM No Asbestos Detected (B) Skip Trowel Texture in Skylights Surfacing 3 ~100 sq.ft. Friable Non-ACM No Asbestos Detected (C) Drywall System throughout Miscellaneous 2 ~1,200 sq.ft. Friable Non-ACM No Asbestos Detected (D) Brick Mortar on Fireplace Miscellaneous 2 ~200 sq.ft. Friable Non-ACM No Asbestos Detected (E) 12 x 12 Vinyl Tile Miscellaneous 2 ~60 sq.ft. Non-Friable Non-ACM No Asbestos Detected (F) Tile Mastic Miscellaneous 2 ~60 sq.ft. Non-Friable Non-ACM No Asbestos Detected (G) Ceiling Tile in Closet Miscellaneous 2 ~1,5 sq.ft. Friable Non-ACM No Asbestos Detected (H) Carpet Miscellaneous 2 ~500 sq.ft. Non-Friable Non-ACM No Asbestos Detected (I) Carpet Pad Miscellaneous 2 ~500 sq.ft. Non-Friable Non-ACM No Asbestos Detected Key: ACM Assessment Categories: 1- Damaged or significantly damaged Thermal Systems Insulation 2- Damaged friable surfacing ACM 4- Damaged or significantly damaged friable Miscellaneous ACM 5- ACM with potential for damage 6- ACM with potential for significant damage 7- Friable ACM with low potential for damage Other- ACM not classified in the above Assessment Categories N/A- Not Applicable * Square footage is estimated and not for bidding purposes 11/09/202201/23/2023 sami Project #-BG 091922 Durant 4 7.0- DESCRIPTION OF SAMPLING AREA • Skip Trowel Texture on ceilings and skylights • Drywall System on ceiling and under paneling • Mortar on fireplace • 12 x 12 Tile and Mastic in Kitchen • Ceiling Tile in closet • Carpet and Pad Sampling Locations N NTS 11/09/202201/23/2023 sami Project #-BG 091922 Durant 5 8.0- CONCLUSION No asbestos was detected in any of the samples taken. Sincerely, Josh Johnson 11/09/202201/23/2023 sami Project #-BG 091922 Durant 6 9.0- LAB REPORT 11/09/202201/23/2023 sami Project #-BG 091922 Durant 7 11/09/202201/23/2023 sami Project #-BG 091922 Durant 8 11/09/202201/23/2023 sami Project #-BG 091922 Durant 9 11/09/202201/23/2023 sami Project #-BG 091922 Durant 10 11/09/202201/23/2023 sami Project #-BG 091922 Durant 11 11/09/202201/23/2023 sami Project #-BG 091922 Durant 12 11/09/202201/23/2023 sami Project #-BG 091922 Durant 13 11/09/202201/23/2023 sami Project #-BG 091922 Durant 14 10.0- CERTIFICATES 11/09/202201/23/2023 sami