Loading...
HomeMy WebLinkAboutFile Documents.931 Gibson Ave.0091-2022-BCHO (9) 11)1.1 IvaI IL THE CITY OF ASPEN City of Aspen and Pitkin County FIREPLACE & WOODSTOVE REGISTRATION *Parcel Id number: 2737 074 __ 00 004 Street Address:931 Gibson Ave Owners Name: 107 Thunderbowl LLC *Required—Contact Assessors offices at 920-5160 Registration will not be accepted without a Parcel Id number List all devices in your home (2 are allowed per building, except for gas appliances) Note:If the number, type and location on this registration form do not match what is show on your plans or what is actually installed,your permit or Certificate of Occupancy will be denied. Type of Building (circle one): (Residential , Other Type of device Room Existing New Make & Model Wood burning fireplace (select one) ?Site-built masonry ?Factory built insert: model number: Gas log fireplace Living room 110 (select one) ?Site-built masonry 1 ?Factory built insert: model number: (1)Custom-Stellar Hearth Shop drawing attached Certified woodstove Gas fireplace appliance Speakeasy 101 2 (1)Enviro Q1fp-EQ.31 (attach spec sheet) and Guest Suite 201 (1)Valor 530 Portrait-EQ.32 Roof Deck and Patio 2 (2)Custom Paloform appliances If any devices are being removed, please describe here, i.e. "old woodstove removed from living room" Signature of applicant Date RECEIVED G:\city\building_dept\Aspen 2004 Checklists\fireplace registration .doc 0 5/0 8/2 0 2 3 over ASPEN BUILDING DEPARTMENT ASPEN/PITKIN COUNTY FIREPLACE AND WOODSTOVE REGULATIONS In order to keep our air as clean as possible,the elected officials of Aspen and Pitkin County have passed ordinances to regulate the number of fireplaces and woodstoves that can be installed in any building. Building permit applicants must file a fireplace/woodstove registration with the City of Aspen Building Department or the Pitkin County Building Department before the building permit is issued. Pitkin County is separated into 2 areas. One is the non attainment area,which includes the City of Aspen and the Metropolitan areas of the county,i.e.Mountain Valley,Red Mountain,Difficult Campground,T Lazy 7 Ranch,and part of Starwood. The other is the attainment area which includes the less densely populated parts of the county,i.e.Brush Creek Village,Holland Hills and Old Snowmass. Decorative gas appliance:A device utilizing natural gas as a fuel gas designed to appear as a real fireplace with a 4 to 5 inch Class B vent or direct vent,fixed glass door and a firebox no deeper than 24 inches. Certified Woodstove: Colorado Phase III certified woodstove or a Phase II EPA certified woodstove. Gas log fireplace:Meet all codes for burning wood but are used with gas logs. They are not allowed in bedrooms. Aspen and Metropolitan Areas of Pitkin County in the non attainment area New buildings in the non attainment area may have either 2 gas log fireplace or 2 certified woodstoves or 1 each. They may also have an unlimited number of decorative gas appliances. Wood burning fireplaces cannot be installed,nor may coal be used as fuel. Remodeling or an addition to an existing home in the non attainment area • If the building has 2 or more fireplaces,gas log fireplaces or woodstoves,they only devices you can add are decorative gas appliances. • If the building has 1 fireplace,gas log fireplace or woodstove,you may add 1 gas log fireplace and an unlimited number of decorative gas appliances. • If a building has more than 2 fireplaces,gas log fireplaces;if one is affected by the remodel it must be removed. • If a building has only 1 or 2 fireplaces,woodstoves or gas log fireplaces,please keep in mind: o If you alter the firebox of a fireplace,it must be converted to gas logs or removed. o If a woodstove is moved,it must be removed or replaced with a department certified woodstove. Attainment Area in Pitkin County New residential buildings in this area may have one wood burning fireplace and one gas log or certified woodstove. If there is no fireplace,you may have either 2 gas log fireplaces or 2 certified woodstoves or 1 each. Buildings may also have an unlimited number of decorative gas appliances. Remodeling or an addition to an existing building in the attainment areas • If the building has 2 or more fireplaces or woodstoves,the only devices you can add are decorative gas appliances. • If you have 1 fireplace or woodstove,you may add 1 gas log or certified woodstove and an unlimited number of decorative gas appliances • If a building has more than 2 fireplaces or woodstoves: if one is affected by a remodel,it must be removed • If a building has on 1 or 2 fireplaces,woodstoves or gas log appliances,please keep in mind: o If a woodstove is moved,it must be removed or replaced with a department certified device. o If you alter the firebox of a fireplace,and already have another fireplace,it must be converted to gas log Non residential buildngs(which include commercial buildings,restaurants,lodges,public buildings,and hotels)in the attainment area of Pitkin County are allowed to have gas appliances. RECEIVED G:\city\building_dept\Aspen 2004 Checklists\fireplace registration .doc 0 5/0 8/2 0 2 3 over ASPEN BUILDING DEPARTMENT EQ.31 - ENVIR0 I.( kik 1 FIREPLACE Installation Reference Guide or REFER TO OWNER'S MANUAL F I ' ' 'EQUIREMENTS AND ADDITIONAL PRODUCT INSTRUCTIONS Minimum Framing Dimensions )V Note:When framing the unit,care must be taken to consider 1 the final floor thickness,the bottom of the fireplace must sit flush with the finished floor to ensure proper fit of the Wood Framing Stud surround components Width 251/4" 641 mm Steel Framing Stud Framing Height-Rear Vent 351/4" 895 mm ✓ t / Top Vent 251/2" Framing Height-Top Vent 41" 1041 mm 41 648 mm 1041 mm Gas Inlet (Distance from Back) 615�16" 176 mm 251/4"_•,,, 17 641 mm Depth (No Surround Panel) 5 456 mm �16' Rear Vent *Minimum dimension with only an elbow off the Gas Inlet 35'/a" top.Any additional vertical rise added will increase 615/16" 895 mm the enclosure height accordingly. 176 mm 1 Ilr N \ I Clearance to Combustibles A-Side of unit to side wall 7" 254 mm 1- B-Minimum clearance to mantel height See Chart See Chart ti A C-Front of door to edge of floor protection 12" 305 mm B D-Minimum aclove width 34" 864 mm i.- EIV : / 05/08/202 . r kI BUILDING DEPARTMENT Mantle & Non-Combustible Fireplace Dimensions Clearances: Top Vent 14.250" 15 1/4" �(362mm)y (387mm)� r 1 . .' 12"(305 mm)Mantle 25 1/,"(481 mm) _ (429mm) I--N 2"(51 mm)Mantle 17 13/16" ,� ) 16 7/8 10"(254 mm) 1/2"(12.7mm) t 1 151/2 Non-Combustible thick non- 41" 41/2" (479mm) Facing combustible facing (1041 mm) (114mm) (387mm) minimum _i_ l fr Ir from bottom I 7"(178 mm) of unit 3 5/8" minimum from 35" y (93mm) side of door to (889 mm) 065/8" - 25" side wall minimum (168mm) (635mm) -4111 from bottom II. 043/8" 20"(508mm) of unit (112mm) 18 3/4"(476mm) .• 1%"(32mm) I :4161/2" �. 21" thick non- I l� 76mm) (533mm) combustible 251/4" 275/8" 243/4" • 183/4" floor (641 mm)I (702mm) 253/16" j 12"(305 mm)minimum from wallIfheaah is flush withflooring I _ 5 3/8"(136mm) Minimum Venting Requirements Rear Vent This appliance uses a 4" (101mm) exhaust / 6 5/8" (168mm) air 251/4" 251/4" intake vent pipe system. For safe and proper operation of the (641mm) r (425mm) appliance follow the venting instructions exactly. Deviation from I f CI ~__--- 1� the minimum vertical length can create difficulty in burner start-up I '—, ' E.. and sooting.Allow several minutes for the flame to stabilize after I I 1.1 ignition under extreme vent configurations.It is recommended for • �85/8" (16mmJ vent lengths that pass through unheated spaces (garages, attics, 2 crawl spaces)be insulated to minimize condensation. See manual li �a3/a" 48mm) (112mm) for more info. =- CREPT_ YWil' i - •a> . . *Note:Glass Units can NOT be rear vented. xl x 1715,0 Mantel Projections (547mm) Based on Y2" building material Note:Mantle height dimensions are based from the bottom of 421/2" the appliance. (1079mm) Fiberglass Frflaming clearance of Insulation 1"+l�h"for fl 2x4 _ - - - I TOP(MIN)) 3 -O. 42" \ p 41„ 12"MAN 36 3/4" Non comb 0. (933mm) one _ \ / Framing clearance of x _ 40" 35Y"+1'h"for flat2x4 - O. - REAR(MIN) • 0 39" l b 33" 0'� (838mm) 38" I I TOP(MIN) x - 37" 21.5" = 36" • • (548mm) REAR J 35„ 2"MANTLE < REc :iv : p., 1 7 5 d. S A 7 A a 05/081/202 BUILDING DEPARTMENT Rear Vent Conversion Clean Face Install Step 1:Using a T20 screwdriver remove the vent collar,base plate, The Q1 is shipped with the Tiling Flanges packaged at the cover plate and exhaust spigot(28 screws total) back of the unit.To install as a fireplace you must use the Tiling Flanges and Rear Standoffs.The Tiling Flanges double as the Side Standoffs.Take the three flanges out of the packing foam Vent Collar and install them onto the unit in the desired position.There are three positions the Tiling Flanges can be set to Measure 04: 14‘117A Base Plate the non-combustable and tiling material to determine which setting will work best for the install.With a T20 screwdiriver, 44 install the flanges as shown below using the T20 screws provided in the Manual Bag.The top and bottom screws that I� Exhaust Spigot hold the surround mounts will need to be removed and re-used , l \\I„ 44 to install the Tiling Flanges. ,►,_ \, Cover Plate 11 Re-use Screw .- • ''' I Li' Surround ` . i Mount Switch the removed parts around as shown below and re-install all Re-use Screw 28 screws.To correctly install the base plate keep the locating notch 173r4' 17/, 163/.° on each side at the bottom.Also note the exhaust spigot uses a lower set of holes when setup as a rear vent. ass" 1.375" 1.875" Use lower set of Setting 1 Setting 2 Setting 3 40* holes Victorian Face Installation \/� r . Surround Mounts must be swapped and S ' • installed prior to finishing. �� • 18'fs"Total Depth-e •Finishing opening must be spaced'/2'off " Thick Finishing �'• the cabinet sides for surround mounts. �, I/ 1613A6'Framing Depth ��1�2n 1/2"� 0 �� I �II , :7 ILocating Notch I L —' • Ij III — — - . ---_ _ igek o Tiling flanges at furthest bath& 0 8/202 . ASPEN BUILDING DEPARTMENT EQ.32 530 Portrait with 539 & 550 Arches ZC tdalor Dimensions, Clearances, and September 10 Radiant Gas Fireplaces Framing 1/1 Dimensions & Clearances-539 and 550 Arch Fronts (539 Windsor Arch shown) 26" 20„ ZC Stand-offsMantel depth "X" Min. clearance "Y" r2" 1"—6" 34" _ ` 7"—8" 36„ 6-5/8" 9"— 12„ 38„ Outer dia. C0 k) Cast Plate i. Top ° m 38" + 1"for every 7 4"" Outlet KJ 12„ + inch beyond 12" _ _ 1"J t2-1/8" /// \ Side Mounting Brackets Max 8"deep mantel leg at edge of protruding arch 39" 'X' 13-1/8" Mantel Fixing Points(4) ow 11-1/8" -_ ZC Stand-offs — 4"" Top �^\ � � Outlet )'v �i r \ 'Y' 1�- 1 1i it-1- Min.36"to / combustible `Y' // materials N 'ilililililililil filililililiili dl J 4-1/2" 39" Minimum depth .-r iFixing Points(4) some installations ' I may require more,,' i o _ 37„ y,„„,,,,,,,,W\JOI1,l m \' Shaded Area O 3" \ Outside of Arch • \ \ may be covered < \ with max 3/4'thick \ \ combustible material \• � � such as wood L '�. �� \ iGlililililil.IGlillIIGGlilii \ `2•�`c���a`'��\ IIIIIIIIMMINOWI `e"' SQa s`oi yea ±sue i■, I ��a!`o ate 3," Qe' Framing Diagram RECEIV ED Miles Industries Ltd. • 190-2255 Dollarton Highway•North Vancouver,BC•V7H 3B1 Tel:604.984.3496 or 1.800.468.2567•Fax:604.984.0246 or 1.800.268.0333 0 5/0 8/2 0 2 3 www.valorfireplaces.com ASPEN BUILDING DEPARTMENT 8 7 6 5 4 3 2 I NOTES: SECTION A-A /, 0 NO COMBUSTIBLE MATERIAL WITHIN 6"OF THE TOP OF THE FIREPLACE. COMBUSTIBLE MATERIAL SHALL NOT BE PLACED DIRECTLY ON THE FACE OF THE FIREPLACE,TOP. I--- 2 NO COMBUSTIBLE MATERIAL WITHIN 1"OF THE SIDES AND BACK OF THE FIREPLACE. 1 1/4" f4\ 011.111% F COMBUSTIBLE MATERIAL SHALL NOT BE PLACED DIRECTLY ON THE FACE OF THE FIREPLACE,BACK AND SIDES. /� 3 1"CLEARANCE TO B-VENT MUST BE MAINTAINED. 11 0 . \ 4 GAS PRESSURE LINE:40,000 BTU MEASURED AT 7.0"W.C.REQUIRED. NG 1 POWER REQUIREMENT: 120 VAC,5 AMP MAX DRAW. ,5 STEEL 3"SURFACE MAY BE LEFT EXPOSED OR COVERED WITH COMBUSTIBLE FINISHING MATERIAL.FASTENERS SHALL NOT PENETRATE THE 3"SURFACE. I__I N ,4•A , /-1(,:, /6\ COMBUSTIBLE MATERIAL SHALL NOT BE APPLIED TO THIS SURFACE SHOWN ABOVE THE 3"DIMENSION. 1 1/4" 1 1/4" I NON-COMBUSTIBLE MATERIAL MAY BE APPLIED TO SURFACE SHOWN PRIOR TO FINISHING MATERIAL. 36" E IF FINISHING MATERIAL REQUIRES A STRUCTUAL BACKER. 13 13 A ® ,If e E / \ THE 1/2"CLEARANCE TO COMBUSTIBLES MUST BE MAINTAINED ON THIS SURFACE. N IF THE 1/2"STAND OFFS ARE REMOVED,ONLY NON-COMBUSTIBLE MATERIAL SHALL BE INTALLED AGAINST THIS SURFACE. 10 AI 1/2"INCH STAND OFFS ARE INCLUDED ON FACE OF FIREPLACE. ® ® / l\ l ,/8\ IF STRUCTURAL BACKER IS REQUIRED FOR FINISHING MATERIAL, \�COMBUSTIBLE MATERIAL IS ALLOWED IN THE AREA SHOWN BELOW THE 3"DIMENSION. 28 1/32" i` itl /9\ DIMENSION SHOWN IS ALLOWABLE FINISHING DIMENSION. THIS IS THE OPENING SIZE REQUIRED ArA TO FIT THE GLASS PANELS INTO THE FIREPLACE. FINISHING MATERIAL SHALL NOT OVERLAP DIMENSION SHOWN. Mr I AFLAT COVERS WILL COVER THE COMPONENT ACCESS AREA. 14" I 95 8"FLUE GAS AND ELECTRICAL INLETS ARE LOCATED BEHIND THESE PANELS. B-VENT 1,....... D THESE ARE USED FOR MANUFACTURING PURPOSES AND MAY BE USEDIlr ® ®® D AFTER FIREPLACE INSTALLATION TO ACCESS COMPONENTS DURING SERVICE. ' THERE SHALL BE ACCESS FROM THE INSIDE OF THE FIREPLACE AS WELL. 22 1/8" 11 FIREPLACE OPTIONS: 111 FIREPLACE SHALL HAVE LINEAR FLAME DOWN THE LONG AXIS,RIBBON BURNER. 4 44 1/4" FIREPLACE SHALL HAVE MEDIA BED LIGHTING. H FIREPLACE SHALL HAVE DRIFTWOOD LOG SET. 38 3/16" 12 DELETED ►- 4 1/2" ► 9 /� / \ FIREPLACE SHALL BE DEISNGED TO ACCEPT FIELD INSTALLED, 1 1/4"THICK MAXIMUM 1 REFRACTORY PANELS,PROVIDED BY OTHERS.PANELS WILL BE ON EACH SIDE AND I - A,,,, l I A_____ �� 11 i I 11 BACK WALL OF THE FIREPLACE. c c DELETED 3"— .------------ A /�� A GLASS SHALL NOT BE DIVIDED INTO SECTIONS.GLASS SHALL BE SAFE T TOUCH SYSTEM THAT 1 •� 1 . COMPLIES WITH ANSI STANDARD Z 21.50,MAX TEMPERATURE 172°F. • 2X 3 1/32" 16 INTAKE COLLAR CAN BE ROTATED TO VENT OFF THE SIDE,OR FROM THE RECESSED BOTTOM OF THE FIREPLACE. • oi L — —__—__—_ i i 46" A A • • 9 38" B 3" A 010" stellar custom fireplace Living room 110 1 • 1 1 r INTAKE B COLLAR 1 '. 5" $ . ►n . 8 (� K mi. •. 00) •• • • 10 I , 5/811 FRONT 8,BACK— A -----—-t. ' ) 6 1/8" , I 4 ► 6 17/32" —14" A THE ESTIMATED SHIP DATE WILL BE DETERMINED AFTER THE RECEIPT OF UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES:TOLERANCE-(1)PLACE DEC:±0.1(2)PLACE DEC:±0.06(3)PLACE DEC:±0.031 ANGLE:±2°FRACTION±1/16 A f OUTSIDE MATERIAL. e-EDGE OR INSIDE MATERIAL. OUTSIDE APEX. .-INSIDE APEX.-DIMS ENCLOSED BY AN OVAL ARE CRITICAL DIMENSIONS REV REVISIONS DATE DRFT ENG THIS SIGNED SHOP DRAWING, RECEIPT OF A PURCHASE ORDER AND PART NAME: CURRENT LEAD TIMES. CJ SINGLE SIDE, SAFE-T-TOUCH APPROVED SIGN OFF DATE �� StrELLAr DRAWN BY: DATE: PROJECT NAME: 2 CHANGED UNIT FROM OPEN HEARTH TO SAFE-T-TOUCH.CHANGED ALL NOTES.CHANGED WITH TO SAFE- 5-4-22 ML RB UUU by Heat&Glo M.LEET 4-26-22 931 GIBSON RECEIVED T-TOUCH STANDARDS. ENGINEER: SCALE: SHEET: PART NUMBER: V: 1 PRELIMINARY 4-26-22 ML RB DRAWING AND DESIGN IS PROPERTY OF HEARTH&HOME TECHNOLOGIES R.BERG N/A SHEET 1 OF 1 BW-22350-DIM01�0eZ/2023 8 1 7 I 6 1 ASPEN 5 4 3 2 BUILDING DEPARTMENT LI N-E-36/48/72 Outdoor Fire Pit Burner P A L O F O R M Electronic Ignition Installation+Owner's Manual ji Burner conforms to: ANSI Z21.97/CSA 2.41 - 2017 "Outdoor Decorative Gas Appliances" CSA 2.17-2017 "Gas-fired Appliances for Use at High Altitudes" ADANGER - FIRE OR EXPLOSION HAZARD If you smell gas: C US 1. Shut off gas to the appliance. 2. Extinguish any open flame. 3. If odor continues, leave the area immediately. 4. After leaving the area, call your gas supplier or fire department. o=P� �,��A Failure to follow these instructions could result in fire or explosion, which could �, 9 cause property damage, personal injury, or death. a n Z m 'NSTITtrIt' A WARNING: FOR OUTDOOR USE ONLY. Installation and service must be performed by a qualified installer, service We recommend that our fire pits be installed and serviced by professionals agency, or gas supplier that are certified in the U.S.by NFI (National Fireplace Institute) A WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. An LP-cyllinder not connected for use shall not be stored in the vicinity of this or any other appliance. customA DANGER CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odor. firepits for Q Using it in an enclosed space can kill you. A Never use this appliance in an enclosed space such as a camper, tent, car patio and or home. roof deck WARNING: A If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. RECEIVED INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference 05/08/2023 ASPEN BUILDING DEPARTMENT SAFETY INFORMATION LIN-E-36/48/72 Outdoor Fire Pit Burner l Installation&Owner's Manual 2 AWARNINGS: WARNING: Any modification to this appliance or its 10. Turn the appliance off and let cool before servicing, controls can be dangerous. installing, repairing or covering. Any guard or other protective device removed for servicing the appliance IMPORTANT: This appliance should 1. This appliance, as supplied, is only for use with the must be replaced prior to operating the appliance. be inspected before use and at least type of gas indicated on the rating plate. Only a qualified service person should install, service, once annually by a qualified service 2. When this appliance is connected to a fixed piping or repair the appliance. person. system, the installation must conform to local codes, More frequent cleaning may be required as necessary. It is imperative or in the absence of local codes, to the National HIGH ALTITUDE INSTALLATION that the control compartment, Fuel Gas Code, ANSI Z223.1/NFPA 54, or the p International Fuel Gas Code. The appliance is certified for installations up to 4500' burners and circulating air (1372 m) above sea level per CSA 2.17-2017. At this passageways of the appliance be 3. Keep the appliance area clear and free from altitude range, no changes to the appliance are required kept clean. combustible materials, gasoline and other flammable but heat ratings are derated per the table on the ratings vapors and liquids plate. Please contact Paloform for information regarding DANGER: Carbon monoxide 4. Do not burn solid fuel in this appliance. Do not use installation above 4500' (1372 m). poisoning can lead to death! this appliance to cook food or to burn paper or other CARBON MONOXIDE POISONING: objects. LOCAL CODES Early signs of carbon monoxide 5. Children and adults should be alerted to the hazards poisoning resemble the flu,with of high surface temperatures and should stay away The installation of this appliance must conform with local symptoms including headache, dizziness, to avoid burns or clothing ignition. codes, or in the absence of local codes, with the National or nausea. If you experience these Fuel Gas Code, ANSI Z223.1 • NFPA 54; National Fuel signs,the Fire Pit may not be working 6. Clothing or other flammable materials should not be Gas Code; Natural Gas and Propane Installation Code, properly. Get fresh air at once! Have the hung from the appliance, or placed on or near the CSA B149.1; or Propane Storage and Handling Code, Fire Pit serviced. Some people are more appliance. CSA B149.2, as applicable. affected by carbon monoxide than others, 7. Young children should be carefully supervised when including pregnant women, people with heart or lung disease or anemia,those they are in the area of the appliance. under the influence of alcohol, and those 8. Do not use the appliance if any part has been under at high altitudes. water. Immediately call a qualified service technician NATURAL GAS AND PROPANE: to inspect the appliance and to replace any part of To assist in detecting leaks, an odorant the control system and any gas control which has has been added to natural gas and been under water. propane. However,this odorant can fade, 9. Inspect the appliance before each use. and gas may be present even though no odor exists. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and RECEIVED proper operation of this appliance. 05/08/2023 ASPEN BUILDING DEPARTMENT HOUSING LIN-E-36/48/72 Outdoor Fire Pit Burner l Installation&Owner's Manual 3 1. UNPACK:Account for all parts(p. 14-15) 2. HOUSING: Non-combustible materials only. Review sample housing (below) 3. LEVEL: Housing must be set on a solid, level surface 4. VENTILATION:Allow adequate ventilation from below. Propane burners require ventilation at floor level. (minimum 8 sq. in per foot of burner) 5. DRAINAGE: Housing must allow water to drain efficiently. Under no circumstances should any part of the burner be allowed to be submerged. 6. GAS/ELECTRICAL: Supply lines are routed through the base of the unit and must be installed by licensed trades 7. MEDIA TOPPINGS: Review correct placement(p. 6-7) BURNER ASSEMBLY 41•00/. //1 FLEX CONNECTOR S 10. II PIPE ADAPTER DECORATIVE TOPPING TRAY r•,,, GAS/ELECTRICAL SUPPLY ,1 .4,10 ROUTED INSIDE HOUSING 4. CUTOUT HOUSING-NON-COMBUSTIBLE VENTILATION- 8 SQ IN PER FOOT OF BURNER RECEIVED SAMPLE HOUSIN 05/08/2023 ASPEN BUILDING DEPARTMENT 5" Hinged access panel with cam-lock(specify locking or non-locking) 120" f i 6 o m 'co f _ — fl 42" 60" 18" Ventilation at base-must be unobstructed Powted sel sl Zinc-rich p rimer/Black top coat N IL.\.• I. I 48" LIN-E-48der-coa burner,naturalteve gas 80,000 BTU/h,electronic ignition se 120 VAC receptacle required 30" 8" 34" Base openings 0 0 0 o ► ' e ROOF DECK FP.02 0 0 - o 0 SIGN RECENED sales@paloform.com I paloform.com Custom Robata 120 with offset burner-REV230315 / PALOFORML TEMP-931-Gibson SCALE 3/4"=1' 0�'2 ARA 02 3 ASPEN BUILDING DEPARTMENT 120" Hinged access panel with cam-lock 5 (specify lucking-orinon-locking) co • co f 12" 96" 12" N _ Ventilation at base-do not obstruct Powder-coated steel vessel Zinc-rich p rimer/Black top coat •• - - - - - - - - - - - - - - - - - - - - - - \ 1xLIN-E-36, 1xLIN-E-48 burner, 84" natural gas, 140,000 BTU/h total electronic ignition 34" 8" 30" 5" Th. 120 VAC receptacle required / Base openings O = O j. O • PATIO FP.01 O O O Ii SIGN RE-cavEr sales@paloform.com I paloform.com Custom Robata 120 with 96"burner opening-REV230315 /n Q PALOFORM L] TEMP-931-Glbson-2 SCALE 3/4"=1' 0`2623-19`3�1?02 3 ASPEN BUILDING DEPARTMENT