HomeMy WebLinkAboutFile Documents.332 W Main St.0016-2024-BCHO (4) COMcheck Software Version COMcheckWeb
ril Interior Lighting Compliance Certificate
Project Information
Energy Code: 2021 IECC
Project Title: 332 W Main, Unit 101A- 2024-02-19
Project Type: Alteration
Permit No. 0031-2023-BCOM
Construction Site: Owner/Agent: Designer/Contractor:
332 W Main Street, Unit 101A Ryan Walterscheid Ryan Walterscheid
Aspen, Colorado 81611 Quaking Aspen Holdings, LLC Forum Phi
210 E Hyman Ave., Suite 202 210 E Hyman Ave, Suite 202
Aspen, Colorado 81611 Aspen, Colorado 81611
970-274-9598 970-274-9598
rwalterscheid@forumphi.com rwalterscheid@forumphi.com
Allowed Interior Lighting Power
A B C D
Area Category Floor Area Allowed Allowed
(ft2) Watts /ft2 Watts
1-Office 2008 0.64 1285
Total Allowed Watts = 1285
Proposed Interior Lighting Power
A B C D E
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D)
Fixture Fixture Watt.
Office (2008 sq.ft.)
LED: LT-101-01: Mitchell Flushmount: Other: 1 1 8 8
LED: LT-103-01: Aubrey Chandelier: Other: 7 1 60 60
LED: LT-103-02: Kenyon Picture Light: Other: 2 1 11 11
LED: LT-103-03:Aubrey Chandelier: Other: 5 1 12 12
LED: LT-104-01: Mitchell Flushmount: Other: 3 1 26 26
LED: LT-105-01: Vanity Wall Mount: Other: 2 1 11 11
LED: LT-106-01: Closet Surface Mount: Other: 1 1 5 5
LED: LT-109-01: Nyra 28 Chandelier: Other: 1 1 75 75
LED: LT-202-01: Brambling Ceiling Fan: Other: 1 1 16 16
LED: LT-205-01: Brambling Ceiling Fan: Other: 1 1 16 16
LED: LT-206-01: Seaport Wall Sconce: Other: 1 3 9 27
LED: LT-207-01: Vanity Wall Mount: Other: 3 1 16 16
LED: LT-302-01: Fandelier: Other: 3 2 24 48
LED: C-02: Downlight: Other: 1 27 9 243
Total Proposed Watts = 575
Project Title: 332 W Main, Unit 101A- 2024-02-19 Rend
FigD
Data filename: P��ei1i/f2O6'24
ASPEN
BUILDING DEPARTMENT
Interior Lighting PASSES
Interior Lighting Compliance
Statement
Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the
building plans, specifications, and other calculations submitted with this permit application.The proposed interior lighting
systems have been designed to meet the 2021 IECC requirements in COMcheck Version COMcheckWeb and to comply with any
applicable mandatory requirements listed in the Inspection Checklist.
Mark Hardeman - Senior Project Manager `� ---- 2024-02-29
Name-Title Si nature Date
00
Project Title: 332 W Main, Unit 101A 2024 02 19 21 Re111..,t QZ'/�972�"�
Data filename:
03' � y� 3e�1 �2O�2 4
ASPEN
BUILDING DEPARTMENT
COMcheck Software Version COMcheckWeb
Inspection Checklist
Energy Code: 2021 IECC
ril
Requirements: 0.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
# Plan Review Complies? Comments/Assumptions
& Req.ID
C103.2 Plans, specifications, and/or EComplies
[PR4]1 calculations provide all information Does Not
with which compliance can be
determined for the interior lighting ❑Not Observable
and electrical systems and equipment ❑Not Applicable
and document where exceptions to
the standard are claimed. Information
provided should include interior
lighting power calculations, wattage of
bulbs and ballasts,transformers and
control devices.
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: 332 W Main, Unit 101A- 2024-02-19 Re o the F119gD
Data filename: o 3ei 1ii2 0P'2 4
ASPEN
BUILDING DEPARTMENT
Section
# Rough-In Electrical Inspection Complies? Comments/Assumptions
& Req.ID
C405.2.3. Spaces required to have light- ❑Complies
1 reduction controls have a manual ❑Does Not
[EL22]1 control that allows the occupant to
reduce the connected lighting load in ['Not Observable
a reasonably uniform illumination ENot Applicable
pattern >= 50 percent.
C405.2.1, Occupancy sensors installed in ❑Complies
C405.2.1. classrooms/lecture/training rooms, :❑Does Not
1 conference/meeting/multipurpose
[EL18]1 rooms, copy/print rooms, Not Observable
lounges/breakrooms, enclosed offices, ❑Not Applicable
open plan office areas, restrooms,
storage rooms, locker rooms,
corridors, warehouse storage areas,
and other spaces <= 300 sqft that are
enclosed by floor-to-ceiling height
partitions. Reference section language
C405.2.1.2 for control function in
warehouses and section C405.2.1.3
for open plan office spaces.
C405.2.1. Occupancy sensors control function in ❑Complies
2 warehouses: In warehouses,the ❑Does Not
[EL19]1 lighting in aisleways and open areas is
controlled with occupant sensors that ['Not Observable
automatically reduce lighting power ❑Not Applicable
by 50%or more within 20 minutes of
when the areas are unoccupied.The
occupant sensors control lighting in
each aisleway independently and do
not control lighting beyond the
aisleway being controlled by the
sensor. Lights not turned off by
occupant sensors is done so by time-
switch.
C405.2.1. Occupant sensor control function in EComplies
3 open plan office areas: Occupant ❑Does Not
[EL20]1 sensor controls in open office spaces ['Not Observable
>= 300 sq.ft. have controls 1) ❑Not Applicable
e
configured so that general lighting can pp
be controlled separately in control
zones with floor areas <= 600 sq.ft.
within the space, 2) general lighting in
each zone permitted to turn on upon
occupancy in control zone, 3)
automatically turn off general lighting
in all control zones within 20 minutes
after all occupants have left the
space, 4) are configured so that
general lighting power in each control
zone is reduced by>= 80%of the full
zone general lighting power within 20
minutes of all occupants leaving that
control zone.
C405.2.2, Each area not served by occupancy ❑Complies
C405. sensors(per C405.2.1.1) have time- ❑Does Not
1 switch controls and functions detailed
[EL21]2 in sections C405.2.2.1. ❑Not Observable
❑Not Applicable
I I
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) � ��
Project Title: 332 W Main, Unit 101A-2024-02-19 Re o1L t�: / 9���
Data filename: ge/1 4'/f2 Op2 4
ASPEN
BUILDING DEPARTMENT
Section
# Rough-In Electrical Inspection Complies? Comments/Assumptions
& Req.ID
C405.2.4, :Daylight zones provided with ❑Complies
C405.2.4. individual controls that control the ❑Does Not
1, lights independent of general area
C405.2.4. lighting. See code section C405.2.3 ❑Not Observable
2 Daylight-responsive controls for ENot Applicable
[EL23]2 applicable spaces, C405.2.3.1 Daylight
responsive control function and
section C405.2.3.2 Sidelit zone.
C405.2.5 Additional interior lighting power ❑Complies
[EL27]1 allowed for special functions per the ❑Does Not
approved lighting plans and is
automatically controlled and ❑Not Observable
separated from general lighting. ❑Not Applicable
C405.7 Low-voltage dry-type distribution ❑Complies
[EL26]2 electric transformers meet the ❑Does Not
minimum efficiency requirements of
Table C405.6. ❑Not Observable
❑Not Applicable
C405.8 :Electric motors meet the minimum ❑Complies
[EL27]2 'efficiency requirements of Tables•
❑Does Not
C405.7(1)through C405.7(4). ❑Not Observable
Efficiency verified through certification
under an approved certification ❑Not Applicable
program or the equipment efficiency
:ratings shall be provided by motor
manufacturer(where certification
programs do not exist).
C405.9.1, :Escalators and moving walks comply ❑Complies
C405.9.2 with ASME A17.1/CSA B44 and have ❑Does Not
[EL28]2 ;automatic controls configured to
:reduce speed to the minimum ❑Not Observable
permitted speed in accordance with ❑Not Applicable
:ASME A17.1/CSA B44 or applicable
:local code when not conveying
:passengers.
C405.10 Total voltage drop across the I❑Complies
[EL29]2 combination of feeders and branch ❑Does Not
circuits <= 5%.
❑Not Observable
❑Not Applicable
C405.1.1 ;At least 90%of dwelling unit ❑Complies
[EL30]2 permanently installed lighting shall ❑Does Not
:have lamp efficacy>= 65 Im/W or
:luminaires with efficacy>= 45 Im/W ❑Not Observable
I or comply with C405.2.4 or C405.3. ❑Not Applicable
C405.11, 150%of 15/20 amp receptacles ❑Complies
C405.11.1 installed in enclosed offices, ❑Does Not
[EL31]2 conference rooms, copy rooms, break
rooms, classrooms and workstations ❑Not Observable
and > 25%of branch circuit feeders ❑Not Applicable
;for modular furniture will have
:automatic receptacle control in
:accordance with C405.11.1.
Additional Comments/Assumptions:
!High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) CEINFD
Project Title: 332 W Main, Unit 101A-2024-02-19 ReolEr /
Data filename: gei 145/fk Op2 4
ASPEN
BUILDING DEPARTMENT
Section
# Final Inspection Complies? Comments/Assumptions
& Req.ID
C303.3, :Furnished O&M instructions for ❑Complies
C408.2.5. systems and equipment to the ❑Does Not
2 building owner or designated
[F117]3 representative. ❑Not Observable
❑Not Applicable
i
C408.1.1 Building operations and maintenance ❑Complies
[F157]1 documents will be provided to the ❑Does Not
owner. Documents will cover
manufacturers' information, ❑Not Observable
specifications, programming ❑Not Applicable
procedures and means of illustrating
to owner how building, equipment and
systems are intended to be installed,
maintained, and operated.
C408.2.5 Furnished as-built drawings for OComplies
[F116]3 electric power systems within 90 days ❑Does Not
of system acceptance.
❑Not Observable
❑Not Applicable
C408.3 Lighting systems have been tested to❑Complies
[F133]1 ensure proper calibration, adjustment, ❑Does Not
programming, and operation.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) g/I9gD
Project Title: 332 W Main, Unit 101A-2024-02-19 Re o1l t�:
Data filename: gei 1 i/f2 Op2 4
ASPEN
BUILDING DEPARTMENT