HomeMy WebLinkAboutFile Documents.205 E Durant Ave.0127-2023-BRES (17)Per this project’s asbestos inspection report, your project does not require a State asbestos abatement permit. However, the following OSHA regulation must be strictly adhered to: Standard Title 29, Part 1910.134, 1910.1001, and 1926.1101 of the Code of Federal Regulations. It is recommended that you familiarize yourself with these regulations and have a certified General Abatement Contractor (GAC) conduct the removal of the Asbestos Containing Material (ACM) under engineering controls and that once the removal process is completed, a visual inspection and clearance air monitoring be conducted by an independent, certified Air Monitoring Specialist. Furthermore, identified ACM may be in areas which were either not covered in the scope of the asbestos inspection or were inaccessible or hidden due to their application during the construction process and their subsequent enclosure or covering with building and finish materials. These areas should be inspected when renovation or demolition activities are scheduled which may disturb the materials within, or beneath these barriers. IF ROOF/CEILING IS FULLY EXPOSED: INSULATION REQUIRED If finish materials are removed to expose framing cavities or dropped ceilings are removed to expose areas where insulation can be installed in the thermal envelope, insulation must be installed: Residential: R-49 Commercial: R-60 Ordinance 1, 2023 IF FRAMING CAVITIES ARE EXPOSED: QUALITY INSULATION REQUIRED If finish materials are removed to expose framing cavities in the thermal envelope, those cavities must be filled with insulation installed to Grade I quality standard (ICC/RESNET 301). Ordinance 1, 2023 Batts/loose fill: Insulation shall be closely fitted wiring, pipes, etc. and avoid substantial gaps, voids or compression. No more than 2% of the total insulated area shall be compressed or contain gaps or voids in the insulation. These areas shall not be compressed more than 3/4 inch. General Electrical Requirements Any areas affected by the renovation must be brought up to the current electrical code including: tamperproof receptacles (NEC 406.12), ground-fault circuit interrupter protection (NEC 210.8), arc-fault protection (NEC 210.12), receptacle spacing (NEC 210.52) etc. 100% of lamps in permanently installed light fixtures must be high efficacy - IECC R404.1 FIRE RATED HATS & CEILING RADIATION DAMPERS REQUIRED Where floor/ceiling or roof/ceiling assemblies are required to have a fire-resistive rating, recessed fixtures shall be installed such that the required fire resistance will not be reduced. Ducts and air transfer openings penetrating the ceiling of a fire rated ceiling assembly must be protected with a listed ceiling radiation damper. This includes bathroom exhaust fans. (IBC 714.4.2 & 717.6.2) INTERIOR FIREPLACE MANDATORY REQ’S. All fireplaces shall meet the following per (Ordinance 1 Series 2023): - Controlled by occupancy sensing device or a timer switch, so that the system is automatically de-energized when occupants are not present or within an hour of being turned on. - Interior gas fireplaces must be direct vent. - Install per manufacturer's installation instructions. - Installation instructions required on site at time of inspection. READ THIS OR FAIL YOUR INSPECTION! Dropped Ceilings and Soffits beneath fire rated assemblies 2021 IBC 803.13 This applies to the attachment of finishes or furring to any assemblies that are required to be either fire-rated or non-combustible and is separate from the fire-rated assembly requirement. 1. Dropped Ceilings & Soffits: If dropped 1 ¾ inches or less, do one of the following: -Fill spaces with Class A material. -Fill spaces with inorganic or non-combustible material. -Fire block 8 feet in all directions. 2. Dropped Ceilings & Soffits: If dropped greater than 1 ¾ inches: Framing members, hangers, and other assembly members must be non-combustible. You may not use wood. In Type III and V construction only, you may use fire retardant treated wood or non-combustible framing. 3. Dropped Ceilings & Soffits below Heavy Timber T&G ceilings, do all of the following: -One layer 5/8” type X gypsum board directly attached with minimum level one finish. -Drop ceiling according to item 1 or 2 above as applicable. (City Policy) INSTALLATION INSTRUCTIONS REQUIRED ON SITE AT TIME OF INSPECTION 2021 IBC Code References L 100% of lamps in permanently installed lights must be high efficacy, Ordinance 1, 2023. AS Access and service space for maintenance required, 2021 IMC 306 CO Carbon monoxide detector required per Aspen Municipal Code 8.15 DE Clothes dryer exhaust, 2021 IMC 504. Makeup air required if over 200 CFM SE Continuous air barrier required; all exterior joints, cracks, and holes to be caulked, gasketed, sealed, Ordinance 1, 2023 DV Direct vent sealed combustion required, Ordinance 1, 2023 EP Electric panel happy space: 30in x 36in x 78in, not in storage, NEC 110.26 EE Emergency escape and rescue opening required 2021 IBC 1031 ET Exhausts terminate 3ft from prop line and openings, 10ft from intakes, 2021 IMC 501.3.1 GR Guards, 42in min high, 4in max opening. Guards within dwelling unit 36in min high 2021 IBC 1015 HR Handrails 34in-38in high, 2021 IBC 1014 IT Intake openings 10ft from lot line & contaminant sources (vents, streets), 2021 IMC 401.4 MA Make up air required if hood exhausts greater than 400 CFM, 2021 IMC 505.4 V Mechanical ventilation required, Ordinance 1, 2023 F New or replacement fenestration in existing residential buildings shall not exceed 0.28 U-factor, NFRC label required, Ordinance 1, 2023 SG Safety glazing required, 2021 IBC 2406 SA Smoke alarm per NFPA 72 required, 2021 IBC 907.2.11 WFP Window fall protection- operable window less than 24in AFF and greater than 72in above exterior grade: use opening control device listed to ASTM F2090, 2021 IBC 1015.8 01/11/ 2 0 2 4 Sam I. Amenity Energy Use Approved (2021 CODE) RREMP CREMP PERMIT #:_______________DATE:________ SNOWMELT:_____________________________ POOL: _____________________________ SPA: _____________________________ OFFSET:_______________________________ REMP SHEET(S): _______________________ REVIEWED BY: _________________________ MINIMUM BOILER AFUE: _________________ HEAT TAPE: _____________________________ HEAT MAT: _____________________________ Ex HEATERS: ____________________________ Ex FIREPLACES: _________________________ In FIREPLACES: _________________________ 0127-2023-BRES X 01/11/2023 24,500 BTU's REMP worksheet None - $5,663.05 paid on this permit. Sam Irmen N/A N/A N/A N/A N/A N/A N/A N/A SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK It should be known that this review shall not relieve the applicant of their responsibility to comply with the requirements of the City of Aspen Municipal Code. Pursuant to Sec.26.104.050, any permit or approval issued in error or otherwise not in conformity with the requirements of this Title, shall be void. Similarly, any permit or approval issued in reliance upon or as a result of, a materially false statement or representation made in the process of obtaining the permit or development approval shall, likewise, be void. Any person having received a void or voidable permit or approval shall not be relieved from having to comply with all applicable terms and conditions of this Title and the City shall not be estopped from fully enforcing same. 10/23/2023 MODEL ZCVRB47N/NE ZCVRB47LP/LPE MQZCVRB47NE2†MQZCVRB47LPE2† Fuel Natural Propane Gas Control Millivolt / IPI Millivolt / IPI Input Max.24,500 BTU 24,500 BTU Input Min. 16,500 BTU 20,500 BTU FE (P.4.1-15)55.26% / 57.31%55.01% / 57.10% Glass Size 40 5 /8”W x 13 7/8 ”H 40 5 /8”W x 13 7/8 ”H Venting 4”/7" Flex or 4” x 6 5/8" Hard Pipe 4”/7” Flex or 4” x 6 5/8” Hard Pipe SERENE 47 PRODUCT SPECIFICATIONS SERENE 47 Unit Illustrated: ZCVRB47N Zero Clearance Direct Vent Gas Fireplace (Natural Gas), ZCVRB47S1SS Surround Stainless Steel, MQRBRW Birch Log Set, ZCVRB47PL Porcelain Liners, and MQSTONE10 Decorative Stones. VENTED CHASE OPTION SERENE 47 WITH OPENINGS (NO GRILLS) Min. 105 sq/in. Min. Enclosure Height 70” Min. Opening Below Ceiling 1-1/4” WITH GRILLS (MIN. AIR FREE OPENINGS) 105 sq/in. Min. Enclosure Height 70” Grill Opening (Max. distance from top of enclosure) 2” ZCVRB47N Zero Clearance Direct Vent Gas Fireplace (Natural Gas), MQEMBER Ember Chunks, MQZCVRB47RLF Fluted Liners. 10/23/2023 A 16 3/16” B 7 7/8” C 6 7/16” D 1/4” E 15 7/16” F 2 9/16” A 47 13/16” B 3 13/16” C 46 9/16” D 2 1/2” E 1 9/16” OPTIONAL SIDE GRILL – VL60EGS A B C D FRONT VIEW OPTIONAL FRONT ENCLOSURE GRILL – V46EG A C B FRONT VIEW D E SIDE VIEW SIDE VIEW E F TOP VIEW SERENE 47 PRODUCT DIMENSIONS *dependent of finishing material used. FRAMING DIMENSIONS Width Height Depth 47” 38 3/4” 18 1/4”* FIREPLACE DIMENSIONS Width Height Depth 46 5/8” 38 5/8” 17 3/4” A 46 5⁄8” B 41 5⁄8” C 38 5⁄8” D 35 11⁄16” E 2 1⁄4” F 3⁄4” G 15 7⁄8” H 11” I 8 13⁄16” J 34 5⁄8” K 17 3⁄4” L 11 1⁄16” M 29 1⁄16” N 31 11⁄16” O 17 3⁄4” P 2 11⁄16” Q 3 3⁄16” A BC E G H I D F E M N O P Q A J K L 7”4” VENT SHIELD VENT SHIELD TOP VIEW FRONT VIEW SIDE VIEW OPTIONAL WALL SURROUND E F D C B A A 44 5/8” B 1 1/2” C 1 1/2” D 17 3/4” E 1” F 1 3/4” ZCVRB47S1 FRONT VIEW Unit Illustrated: ZCVRB47N Zero Clearance Direct Vent Gas Fireplace (Natural Gas), MQZCVRB47RLF Fluted Liner. (Shown as a Vented Chase – top of chase is open.) 10/23/2023 1 430 Main St., Cañon City, CO 81212 ▪ (719) 430-5333 ▪ 3rocksengineering.com September 18, 2023 Rod Guillonta Guillonta Property Services 175 Midland Ave Suite 3 Basalt, CO 81621 Re: 205 Durant Avenue, unit 1I, Aspen, CO Mr. Guillonta: At your request, we have reviewed the interior remodeling project which you are engaged in, at the subject property at 205 Durant Avenue. In this remodel, three pocket doors are planned, and one new opening to a hallway, from the family room. Since there is the possibility that these changes would affect the structure, you have engaged us to advise you on any planned structural work that needs to be done. The two new pocket doors to be added to the primary bathroom, and to the master suite itself are through interior partition walls. However, when performing the work take care to shore the ceiling and observe the framing above so as not to remove support even from minor parts. A third pocket door was planned in front of the washer and dryer. This pocket may be added to the inside face of the wall, but we will advise you not to disturb the sheathing of this wall as shown on the Citrus+Steel architectural drawings. An external slider barn style door may be added, or an external pocket may be added. This wall is the separation wall to an adjoining unit. Lastly, a new opening of 5’-2” clear is to be added directly into the hall to the master suite. This may be accomplished by framing with new 6x6 posts (or (4)2x6, two trimmers, two jacks) and a new 5 ¼” x 9 ¼” LVL, Fb=2750-psi or higher. Post load is 9753-lbs for two levels plus roof, or 3146-lbs per linear foot of beam. Loads are given to so that you may anticipate temporary shoring requirements. Overall load path is through a steel beam in the parking ramp below the condos, and has not changed. Sincerely, Derek L. Dippon, P.E. Structural Engineer 10/23/2023 01/11/ 2 0 2 4 Sam I. STC 56 2x4 stud wall, RSIC-1, Drywall furring channel, 3.5”insulation, 1 layer 5/8” gypsum board each side UL U305 U309 U311 U331 THE RSIC-1 SOUND ISOLATION CLIP Floor/Ceiling & Wall assembly added 5/14/2024 - Sam Design No. L513 February 4, 2022 Unrestrained Assembly Rating — 1 Hr. Finish Rating — 28 Min. This design was evaluated using a load design method other than the Limit States Design Method (e.g., Working Stress Design Method). For jurisdictions employing the Limit States Design Method, such as Canada, a load restriction factor shall be used — See Guide BXUV or BXUV7 * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. 1. Subflooring — Min 3/4 in. thick wood structural panels, min grade "Underlayment" or "Single Floor". Face grain of plywood or strength axis of panels to be perpendicular to joists with joints staggered. 2. Adhesive — Elastomeric adhesive per American Plywood Association Specification AFG-01, applied in 3/8 in. diam beads to top of joists and 1/4 in. diam beads to T& G panel joints. 05/14/2024 justinh see item 10D for RSIC-1 listing in this assembly 10D. Steel Framing Members* — (Not Shown) — As an alternate to Item 10, furring channels and Steel Framing Members* as described below: a. Furring Channels — Formed of No. 25 MSG galv steel, 2-9/16 in. or 2-23/32 in. wide by 7/8 in. deep, spaced 16 in. OC perpendicular to joists. Channels secured to joists as described in Item b. Ends of adjoining channels overlapped 6 in. and tied together with double strand of No. 18 SWG galv steel wire near each end of overlap. b. Steel Framing Members* — Used to attach furring channels (Item a) to joists (Item 6). Clips spaced 48 in. OC., RSIC-1 and RSIC-1 (2.75) clips secured to alternating joists with No. 8 x 2-1/2 in. coarse drywall screw through the center grommet. RSIC-V and RSIC-V (2.75) clips secured to alternating joists with No. 8 x 1-1/2 in. coarse drywall screw through the center hole. Furring channels are friction fitted into clips. RSIC-1 and RSIC-V clips for use with 2-9/16 in. wide furring channels. RSIC-1 (2.75) and RSIC-V (2.75) clips for use with 2-23/32 in. wide furring channels. Adjoining channels are overlapped as described in Item a. As an alternate, ends of adjoining channels may be overlapped 6 in. and secured together with two self-tapping No. 6 framing screws, min 7/16 in. long at the midpoint of the overlap, with one screw on each flange of the channel. Additional clips required to hold furring channel that supports the gypsum board butt joints, as described in Item 11. PAC INTERNATIONAL L L C — Types RSIC-1, RSIC-V, RSIC-1 (2.75), RSIC-V (2.75) 10E. Steel Framing Members* — (Not Shown) — As an alternate to Item 10. For use in corridors or RSIC-1 WOOD FLOOR CEILING ASSEMBLIES 1 & 2 HOUR: UL L528, L542, L532, L523, L514, L513 Carpet STC 61 IIC 74 Hard Wood STC 61 IIC 55 Tile STC 61 IIC 53