Loading...
HomeMy WebLinkAboutFile Documents.617 W Bleeker St.0052-2022-BCHO (16)SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK SEE NOTES #1 PLANS It should be known that this review shall not relieve the applicant of their responsibility to comply with the requirements of the City of Aspen Municipal Code. Pursuant to Sec.26.104.050, any permit or approval issued in error or otherwise not in conformity with the requirements of this Title, shall be void. Similarly, any permit or approval issued in reliance upon or as a result of, a materially false statement or representation made in the process of obtaining the permit or development approval shall, likewise, be void. Any person having received a void or voidable permit or approval shall not be relieved from having to comply with all applicable terms and conditions of this Title and the City shall not be estopped from fully enforcing same. 617 Bleeker St, Aspen CO 81611 Parcel#: 273512444002 Building Permit #: 0062-2019-BRES Change Order Request 6/28/2022 A change order is being requested for the building structure as-built site location along with an increase to the snow melt area in the REMP permit for 617 Bleeker St. This single family home project is currently under construction, and the existing permit was granted in 2019. Due to micropile shoring walls being surveyed in the incorrect location, it has come to our attention that the building structure was shifted approximately six feet south from the original permitted location. The as built location is within the site setbacks and maintains the same proposed height over topography. Please see the attached revision to the civil drawings along with a request for variance for driveway slope between the garage and alleyway entry due to the change in building location. Also included is a revised drainage report. This change in location also results in slight snow melt area changes to the driveway and walks that are reflected in the RREMP change request along with the increased snow melt areas summarized below. The proposed changes to the RREMP submission consist of adding additional snow melt and revising a spa as non-exempt. Summary of the proposed changes to the R-REMP Permit 1. The planned Spa has been added to the permit, and has moved into the non-exempt category. The Spa is a rhombus shape with 42.09 Sq Ft of water surface. 2. The upper deck area including the area under the proposed spa has been added to the snowmelt area; an additional 403.8 SF 3. The Basement stair has been added to the snow melt area; an additional 49.35 SF 4. The basement egress window has been added to the snow melt area; an additional 10.5 SF 5. The covered entry porch has been added to the snow melt area; an additional 71.97 SF 6. The boiler Efficiency has been updated to reflect spec’d equipment to 97.70% efficiency, the same efficiency is applied to the spa. 7. The areas of the driveway, entry walk, and side entry walk have been updated to reflect field conditions. Total snow melt area has increased to 1430.78 SF (including window well and basement stair) Preliminary calculation of RREMP additional payment owed $24,474.30 if changes are approved. 07/11/2022 Please let me know if any further information would be useful, and thank you for reviewing the application. Best, -Clay Montgomery acm@mpdlstudio.com 734-369-8534 07/11/2022 External Energy Use Approved RREMP CREMP PERMIT #:_______________DATE:________ SNOWMELT:_____________________________ POOL: _____________________________ SPA: _____________________________ OFFSET:________________________________ REMP SHEET: __________________________ REVIEWED BY: _________________________ SNOWMELT SYSTEM AND EQUIPMENT MANDATORY REQ’S. All snowmelt systems shall meet the following: -Any portions in the Right of Way must be on a separate zone. A ROW permit and Permanent Encroachment License are required. -R10 insulation shall be installed under the area to be snow melted or R5 insulation shall be installed under and at the slab edges. (Ordinance 11 Series 2011) -Automatic controls installed for system shut off when pavement temperature is above 50°F and no precipitation is falling. (2009 IECC Sec. 403.8 & 503.2.4.5) -Automatic or manual controls installed for system shut off when outdoor temperature is above 40°F. (2009 IECC Sec. 403.8 & 503.2.4.5) -Inspection by testing hydrostatically at 1½ times max system design pressure, but not less than 100psi, for 15minutes. (2009 IMC Sec. 1208.1) MINIMUM BOILER AFUE: _________________ X 0052-2022-BCHO 3/3/23 1431 sq.ft. 42 sq.ft. A0-04 97.7 none JH APPLICATION ACCEPTED DATE: 2022-07-31 PERMIT NUMBER: 0052-2022-BCHO COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT COVERSHEET PROPERTY INFORMATION ADDRESS: 617 W BLEEKER ST UNIT: PARCEL ID: 273512444002 LEGAL DESCRIPTION: CITY AND TOWNSITE OF ASPEN OWNER: JULES ASPEN LLC PERMIT CONTRACTOR: JANCKILA CONSTRUCTION INC DESCRIPTION OF WORK It was recently discovered due to a survey error the building location needs a revision. The civil drawings including drainage report have been revised for the change order. We are also seeking an increase in snow melt area and a revised RRemp Fee. Due to the as built building location the driveway will need an exemption for exceeding the allowed grade between the alley way entry and garage. A letter requesting the exemption has been prepared by the civil engineer. USE OF BUILDING Single Family FIRE SPRINKLER REQUIRED? Yes CLASS OF WORK Residential FIRE SPRINKLER TYPE NFPA 13 D BUILDING TYPE (IRC) One family REQUIRED SPECIAL INSPECTIONS Structural Steel Welding CONSTRUCTION TYPE VB ENERGY CODE COMPLIANCE RESCheck UA Alternative OCCUPANCY GROUP (IBC) R-3 WORK CHANGES BUILDING FOOTPRINT? Yes CODE EDITIONS 2015 IRC TOTAL SPA SQ.FT. 42 OTHER CODE EDITIONS TOTAL SNOWMELT SQ.FT. 1,430 HISTORIC PROPERTY? No TOTAL POOL SQ.FT. FIRE SPRINKLER EXISTING? No 03/03/2023 justinh 0052-2022-BCHO JULES ASPEN LLC 617 W BLEEKER ST 273512444002 1 Master Permit 0062-2019-BRES