Loading...
HomeMy WebLinkAboutFile Documents.205 E Durant Ave.0127-2023-BRES (16)SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK SEE NOTES #1 PLANS It should be known that this review shall not relieve the applicant of their responsibility to comply with the requirements of the City of Aspen Municipal Code. Pursuant to Sec.26.104.050, any permit or approval issued in error or otherwise not in conformity with the requirements of this Title, shall be void. Similarly, any permit or approval issued in reliance upon or as a result of, a materially false statement or representation made in the process of obtaining the permit or development approval shall, likewise, be void. Any person having received a void or voidable permit or approval shall not be relieved from having to comply with all applicable terms and conditions of this Title and the City shall not be estopped from fully enforcing same. Dwelling Separation Required - 2021 IBC -708 Fire Partitions, 711 Horizontal Assemblies: Walls and floor/ceilings separating dwelling units shall have a fire-resistance rating of at least 1 hour. Walls shall extend from the top of the floor assembly below to the underside of the floor or roof slab or deck above or to the fire-resistance-rated floor/ceiling assembly above. -714: Penetrations must be protected by a through-penetration firestop system. Recessed fixtures shall not reduce the required fire resistance by use of a listed fixture, a listed firehood, or a drywall assembly meeting the required fire resistance. Exhaust fans require ceiling radiation damper. -1207 Sound Transmission: Separating walls and floor/ceilings shall have an STC rating of at least 50. Floor/ceilings shall have an IIC rating of at least 50. 1 2 CHANGE ORDER - 0042-2024-BCHO MASTER PERMIT - 0127-2023-BRES FIRE RATED HATS & CEILING RADIATION DAMPERS REQUIRED Where floor/ceiling or roof/ceiling assemblies are required to have a fire-resistive rating, recessed fixtures shall be installed such that the required fire resistance will not be reduced. Ducts and air transfer openings penetrating the ceiling of a fire rated ceiling assembly must be protected with a listed ceiling radiation damper. This includes bathroom exhaust fans. (IBC 714.4.2 & 717.6.2) 08/19/ 2 0 2 4 Sam I. 07/22/202408/19/ 2 0 2 4 Sam I. 5' - 2 " 15 ' - 0 " 1 S3Scale: 1/4" = 1'-0" Modified Floor Plan (2)2x6 (2 ) 2 x 6 new 2x10 headernew 2x10 header new 2x10 sister new 2x10 header new 2x10 sister new 2x10 sister 4' - 0 " 4' - 0 " 4'-0" ne w me c h . un i t ne w me c h . un i t new mech. unit no sister required 2 S3 shore existing joists prior to cutting! 2nd Floor Plan - 1st Floor Ceiling new 2x10 sister use LU210 to attach the 2x10 header to the sister, and the cut joist to the header. flush framed (10)16d nails at 8" o.c &16d nails 1ft o.c staggered existing behind joist directly bears on the bearing wall, opposite end 2 S3Scale: 1/2" = 1'-0" Detail 430 Main Street Cañon City, CO 81212 719.430.5333 www.3rocksengineering.com p: \ 2 0 2 3 \ 2 3 . 1 4 1 - 2 0 5 d u r a n t r e m o d e l \ h - d w g s \ s t r u c t u r a l \ 2 3 . 1 4 1 - 2 0 5 d u r a n t r e m o d e l . d w g 7/ 1 2 / 2 0 2 4 9 : 1 9 : 2 4 A M DE R E K D I P P O N DU R A N T R E M O D E L PROJECT ENG:DLD QA/QC:---- DRAWN BY:AH PRJ # 23.141 DATE: 09/18/2023 MODIFIED FLOOR PLAN 20 5 E . D U R A N T A V E , U N I T 1 I A S P E N C O , 8 1 6 1 1 ISSUED DATES 9/18/23 FOR CONSTRUCTION 4/17/24 FRAMING REVISION 5/15/24 HVAC OPENINGS 7/12/24 BUILDING OFFICIAL NOTE ---- S3 /3 1 2 3 3 0051004 L LO N IC E S E DC R LA P O F NO R AO D O IS S E NE G I REEN N O P P IDEELKERED 07/22/2024 new 2x10 sister 16d nails at 8" o.c 6d nails 1ft o.c staggered joist directly bears on the bearing wall, opposite end FIRE RATED HATS & CEILING RADIATION DAMPERS REQUIRED Where floor/ceiling or roof/ceiling assemblies are required to have a fire-resistive rating, recessed fixtures shall be installed such that the required fire resistance will not be reduced. Ducts and air transfer openings penetrating the ceiling of a fire rated ceiling assembly must be protected with a listed ceiling radiation damper. This includes bathroom exhaust fans. (IBC 714.4.2 & 717.6.2) HVAC cassettes shall be boxed out with 5/8" type X for 1hr. fire resistance rating. 08/19/ 2 0 2 4 Sam I. 5' - 2 " 15 ' - 0 " 1 S3Scale: 1/4" = 1'-0" Modified Floor Plan (2)2x6 (2 ) 2 x 6 new 2x10 headernew 2x10 header new 2x10 sister new 2x10 header new 2x10 sister new 2x10 sister 4' - 0 " 4' - 0 " 4'-0" ne w me c h . un i t ne w me c h . un i t new mech. unit no sister required 2 S3 shore existing joists prior to cutting! 2nd Floor Plan - 1st Floor Ceiling new 2x10 sister use LU210 to attach the 2x10 header to the sister, and the cut joist to the header. flush framed (10)16d nails at 8" o.c &16d nails 1ft o.c staggered existing behind joist directly bears on the bearing wall, opposite end 2 S3Scale: 1/2" = 1'-0" Detail 430 Main Street Cañon City, CO 81212 719.430.5333 www.3rocksengineering.com p: \ 2 0 2 3 \ 2 3 . 1 4 1 - 2 0 5 d u r a n t r e m o d e l \ h - d w g s \ s t r u c t u r a l \ 2 3 . 1 4 1 - 2 0 5 d u r a n t r e m o d e l . d w g 7/ 1 2 / 2 0 2 4 9 : 1 9 : 2 4 A M DE R E K D I P P O N DU R A N T R E M O D E L PROJECT ENG:DLD QA/QC:---- DRAWN BY:AH PRJ # 23.141 DATE: 09/18/2023 MODIFIED FLOOR PLAN 20 5 E . D U R A N T A V E , U N I T 1 I A S P E N C O , 8 1 6 1 1 ISSUED DATES 9/18/23 FOR CONSTRUCTION 4/17/24 FRAMING REVISION 5/15/24 HVAC OPENINGS 7/12/24 BUILDING OFFICIAL NOTE ---- S3 /3 1 2 3 3 0051004 L LO N IC E S E DC R LA P O F NO R AO D O IS S E NE G I REEN N O P P IDEELKERED 07/22/2024 new 2x10 sister 16d nails at 8" o.c 6d nails 1ft o.c staggered joist directly bears on the bearing wall, opposite end FIRE RATED HATS & CEILING RADIATION DAMPERS REQUIRED Where floor/ceiling or roof/ceiling assemblies are required to have a fire-resistive rating, recessed fixtures shall be installed such that the required fire resistance will not be reduced. Ducts and air transfer openings penetrating the ceiling of a fire rated ceiling assembly must be protected with a listed ceiling radiation damper. This includes bathroom exhaust fans. (IBC 714.4.2 & 717.6.2) HVAC cassettes shall be boxed out with 5/8" type X for 1hr. fire resistance rating. 08/19/ 2 0 2 4 Sam I. 14 ' - 6 " 5' - 2 " 15 ' - 0 " Existing Doors to remain Bedroom Primary Bedroom Family Room Kitchen Load bearing walls Load bearing walls Steel beams below Steel beams below 2 Jack, 2 King studs (2x4 studs) 3 12"x 912" LVL Shore during construction 1150 lbs/ft capacity Form door pocket on inside 1 trim, 1 king stud 1 hr fire rated separation or exterior walls at unit perimeter DO NOT DISTURB HATCHED WALLS Fb= 2750psi 1 S2Scale: 1/4" = 1'-0" Unit 1I Floor Plan (2)2x6 (2 ) 2 x 6 fr a m i n g d i r e c t i o n b o t h l e v e l s a b o v e framing direction both levels above 2 levels above + roof 430 Main Street Cañon City, CO 81212 719.430.5333 www.3rocksengineering.com p: \ 2 0 2 3 \ 2 3 . 1 4 1 - 2 0 5 d u r a n t r e m o d e l \ h - d w g s \ s t r u c t u r a l \ 2 3 . 1 4 1 - 2 0 5 d u r a n t r e m o d e l . d w g 7/ 1 2 / 2 0 2 4 9 : 1 9 : 2 4 A M DE R E K D I P P O N DU R A N T R E M O D E L PROJECT ENG:DLD QA/QC:---- DRAWN BY:AH PRJ # 23.141 DATE: 09/18/2023 FLOOR PLAN 20 5 E . D U R A N T A V E , U N I T 1 I A S P E N C O , 8 1 6 1 1 ISSUED DATES 9/18/23 FOR CONSTRUCTION 4/17/24 FRAMING REVISION 5/15/24 HVAC OPENINGS 7/12/24 BUILDING OFFICIAL NOTE ---- S2 /3 1 2 3 3 0051004 L LO N IC E S E DC R LA P O F NO R AO D O IS S E NE G I REEN N O P P IDEELKERED 07/22/202408/19/ 2 0 2 4 Sam I. 08/19/ 2 0 2 4 Sam I.