HomeMy WebLinkAboutFile Documents.205 E Durant Ave.0127-2023-BRES (16)SMOKE ALARMS AND
CARBON MONOXIDE
DETECTORS REQUIRED
THROUGHOUT DWELLING
UNIT PER CITY OF ASPEN
MUNICIPAL CODE 8.15
These plans must be kept at the
building site or inspection
delays may occur. Construction
shall conform to these plans. All
changes shall be approved by
the building official.
Field Plan Set Must Be Printed In Color
SEPARATE PERMITS ARE
REQUIRED FOR ELECTRICAL,
PLUMBING, MECHANICAL, OR
FIRE SPRINKLER WORK
SEE NOTES #1 PLANS
It should be known that this review shall
not relieve the applicant of their
responsibility to comply with the
requirements of the City of Aspen
Municipal Code. Pursuant to
Sec.26.104.050, any permit or approval
issued in error or otherwise not in
conformity with the requirements of this
Title, shall be void. Similarly, any permit
or approval issued in reliance upon or
as a result of, a materially false
statement or representation made in
the process of obtaining the permit or
development approval shall, likewise,
be void. Any person having received a
void or voidable permit or approval
shall not be relieved from having to
comply with all applicable terms and
conditions of this Title and the City shall
not be estopped from fully enforcing
same.
Dwelling Separation Required - 2021 IBC
-708 Fire Partitions, 711 Horizontal Assemblies:
Walls and floor/ceilings separating dwelling units shall have a fire-resistance
rating of at least 1 hour. Walls shall extend from the top of the floor assembly
below to the underside of the floor or roof slab or deck above or to the
fire-resistance-rated floor/ceiling assembly above.
-714: Penetrations must be protected by a through-penetration firestop
system. Recessed fixtures shall not reduce the required fire resistance by use
of a listed fixture, a listed firehood, or a drywall assembly meeting the required
fire resistance. Exhaust fans require ceiling radiation damper.
-1207 Sound Transmission: Separating walls and floor/ceilings shall have an
STC rating of at least 50. Floor/ceilings shall have an IIC rating of at least 50.
1
2
CHANGE ORDER - 0042-2024-BCHO
MASTER PERMIT - 0127-2023-BRES
FIRE RATED HATS &
CEILING RADIATION DAMPERS
REQUIRED
Where floor/ceiling or roof/ceiling assemblies
are required to have a fire-resistive rating,
recessed fixtures shall be installed such that
the required fire resistance will not be reduced.
Ducts and air transfer openings penetrating the
ceiling of a fire rated ceiling assembly must be
protected with a listed ceiling radiation damper.
This includes bathroom exhaust fans.
(IBC 714.4.2 & 717.6.2)
08/19/
2
0
2
4
Sam I.
07/22/202408/19/
2
0
2
4
Sam I.
5'
-
2
"
15
'
-
0
"
1
S3Scale: 1/4" = 1'-0"
Modified Floor Plan
(2)2x6
(2
)
2
x
6
new 2x10 headernew 2x10 header new 2x10 sister
new 2x10 header
new 2x10 sister
new 2x10 sister
4'
-
0
"
4'
-
0
"
4'-0"
ne
w
me
c
h
.
un
i
t
ne
w
me
c
h
.
un
i
t
new
mech.
unit
no sister
required
2
S3
shore existing
joists prior to
cutting!
2nd Floor Plan - 1st Floor Ceiling
new 2x10 sister use LU210 to attach the
2x10 header to the
sister, and the cut joist
to the header.
flush framed
(10)16d nails at 8" o.c
&16d nails 1ft o.c staggered
existing
behind
joist directly bears on
the bearing wall,
opposite end
2
S3Scale: 1/2" = 1'-0"
Detail
430 Main Street
Cañon City, CO 81212
719.430.5333
www.3rocksengineering.com
p:
\
2
0
2
3
\
2
3
.
1
4
1
-
2
0
5
d
u
r
a
n
t
r
e
m
o
d
e
l
\
h
-
d
w
g
s
\
s
t
r
u
c
t
u
r
a
l
\
2
3
.
1
4
1
-
2
0
5
d
u
r
a
n
t
r
e
m
o
d
e
l
.
d
w
g
7/
1
2
/
2
0
2
4
9
:
1
9
:
2
4
A
M
DE
R
E
K
D
I
P
P
O
N
DU
R
A
N
T
R
E
M
O
D
E
L
PROJECT ENG:DLD
QA/QC:----
DRAWN BY:AH
PRJ # 23.141
DATE: 09/18/2023
MODIFIED FLOOR PLAN
20
5
E
.
D
U
R
A
N
T
A
V
E
,
U
N
I
T
1
I
A
S
P
E
N
C
O
,
8
1
6
1
1
ISSUED DATES
9/18/23 FOR CONSTRUCTION
4/17/24 FRAMING REVISION
5/15/24 HVAC OPENINGS
7/12/24 BUILDING OFFICIAL
NOTE
----
S3 /3
1
2
3
3
0051004
L
LO N
IC
E
S
E
DC
R
LA
P
O
F
NO
R AO D O
IS
S
E
NE G I
REEN
N
O
P
P
IDEELKERED
07/22/2024
new 2x10 sister
16d nails at 8" o.c
6d nails 1ft o.c staggered
joist directly bears on
the bearing wall,
opposite end
FIRE RATED HATS &
CEILING RADIATION DAMPERS
REQUIRED
Where floor/ceiling or roof/ceiling assemblies
are required to have a fire-resistive rating,
recessed fixtures shall be installed such that
the required fire resistance will not be reduced.
Ducts and air transfer openings penetrating the
ceiling of a fire rated ceiling assembly must be
protected with a listed ceiling radiation damper.
This includes bathroom exhaust fans.
(IBC 714.4.2 & 717.6.2)
HVAC cassettes shall
be boxed out with 5/8"
type X for 1hr. fire
resistance rating.
08/19/
2
0
2
4
Sam I.
5'
-
2
"
15
'
-
0
"
1
S3Scale: 1/4" = 1'-0"
Modified Floor Plan
(2)2x6
(2
)
2
x
6
new 2x10 headernew 2x10 header new 2x10 sister
new 2x10 header
new 2x10 sister
new 2x10 sister
4'
-
0
"
4'
-
0
"
4'-0"
ne
w
me
c
h
.
un
i
t
ne
w
me
c
h
.
un
i
t
new
mech.
unit
no sister
required
2
S3
shore existing
joists prior to
cutting!
2nd Floor Plan - 1st Floor Ceiling
new 2x10 sister use LU210 to attach the
2x10 header to the
sister, and the cut joist
to the header.
flush framed
(10)16d nails at 8" o.c
&16d nails 1ft o.c staggered
existing
behind
joist directly bears on
the bearing wall,
opposite end
2
S3Scale: 1/2" = 1'-0"
Detail
430 Main Street
Cañon City, CO 81212
719.430.5333
www.3rocksengineering.com
p:
\
2
0
2
3
\
2
3
.
1
4
1
-
2
0
5
d
u
r
a
n
t
r
e
m
o
d
e
l
\
h
-
d
w
g
s
\
s
t
r
u
c
t
u
r
a
l
\
2
3
.
1
4
1
-
2
0
5
d
u
r
a
n
t
r
e
m
o
d
e
l
.
d
w
g
7/
1
2
/
2
0
2
4
9
:
1
9
:
2
4
A
M
DE
R
E
K
D
I
P
P
O
N
DU
R
A
N
T
R
E
M
O
D
E
L
PROJECT ENG:DLD
QA/QC:----
DRAWN BY:AH
PRJ # 23.141
DATE: 09/18/2023
MODIFIED FLOOR PLAN
20
5
E
.
D
U
R
A
N
T
A
V
E
,
U
N
I
T
1
I
A
S
P
E
N
C
O
,
8
1
6
1
1
ISSUED DATES
9/18/23 FOR CONSTRUCTION
4/17/24 FRAMING REVISION
5/15/24 HVAC OPENINGS
7/12/24 BUILDING OFFICIAL
NOTE
----
S3 /3
1
2
3
3
0051004
L
LO N
IC
E
S
E
DC
R
LA
P
O
F
NO
R AO D O
IS
S
E
NE G I
REEN
N
O
P
P
IDEELKERED
07/22/2024
new 2x10 sister
16d nails at 8" o.c
6d nails 1ft o.c staggered
joist directly bears on
the bearing wall,
opposite end
FIRE RATED HATS &
CEILING RADIATION DAMPERS
REQUIRED
Where floor/ceiling or roof/ceiling assemblies
are required to have a fire-resistive rating,
recessed fixtures shall be installed such that
the required fire resistance will not be reduced.
Ducts and air transfer openings penetrating the
ceiling of a fire rated ceiling assembly must be
protected with a listed ceiling radiation damper.
This includes bathroom exhaust fans.
(IBC 714.4.2 & 717.6.2)
HVAC cassettes shall
be boxed out with 5/8"
type X for 1hr. fire
resistance rating.
08/19/
2
0
2
4
Sam I.
14
'
-
6
"
5'
-
2
"
15
'
-
0
"
Existing Doors
to remain
Bedroom
Primary Bedroom
Family Room
Kitchen
Load bearing walls
Load bearing walls
Steel beams below
Steel beams below
2 Jack, 2 King studs
(2x4 studs)
3 12"x 912" LVL
Shore during construction
1150 lbs/ft capacity
Form door pocket
on inside
1 trim, 1 king stud
1 hr fire rated separation
or exterior walls at unit
perimeter DO NOT DISTURB
HATCHED WALLS
Fb= 2750psi
1
S2Scale: 1/4" = 1'-0"
Unit 1I Floor Plan
(2)2x6
(2
)
2
x
6
fr
a
m
i
n
g
d
i
r
e
c
t
i
o
n
b
o
t
h
l
e
v
e
l
s
a
b
o
v
e
framing direction both levels above
2 levels above + roof 430 Main Street
Cañon City, CO 81212
719.430.5333
www.3rocksengineering.com
p:
\
2
0
2
3
\
2
3
.
1
4
1
-
2
0
5
d
u
r
a
n
t
r
e
m
o
d
e
l
\
h
-
d
w
g
s
\
s
t
r
u
c
t
u
r
a
l
\
2
3
.
1
4
1
-
2
0
5
d
u
r
a
n
t
r
e
m
o
d
e
l
.
d
w
g
7/
1
2
/
2
0
2
4
9
:
1
9
:
2
4
A
M
DE
R
E
K
D
I
P
P
O
N
DU
R
A
N
T
R
E
M
O
D
E
L
PROJECT ENG:DLD
QA/QC:----
DRAWN BY:AH
PRJ # 23.141
DATE: 09/18/2023
FLOOR PLAN
20
5
E
.
D
U
R
A
N
T
A
V
E
,
U
N
I
T
1
I
A
S
P
E
N
C
O
,
8
1
6
1
1
ISSUED DATES
9/18/23 FOR CONSTRUCTION
4/17/24 FRAMING REVISION
5/15/24 HVAC OPENINGS
7/12/24 BUILDING OFFICIAL
NOTE
----
S2 /3
1
2
3
3
0051004
L
LO N
IC
E
S
E
DC
R
LA
P
O
F
NO
R AO D O
IS
S
E
NE G I
REEN
N
O
P
P
IDEELKERED
07/22/202408/19/
2
0
2
4
Sam I.
08/19/
2
0
2
4
Sam I.