HomeMy WebLinkAboutFile Documents.700 Ute Ave.0073-2023-BRES (4)SMOKE ALARMS AND
CARBON MONOXIDE
DETECTORS REQUIRED
THROUGHOUT DWELLING
UNIT PER CITY OF ASPEN
MUNICIPAL CODE 8.15
These plans must be kept at the
building site or inspection
delays may occur. Construction
shall conform to these plans. All
changes shall be approved by
the building official.
Field Plan Set Must Be Printed In Color
SEPARATE PERMITS ARE
REQUIRED FOR ELECTRICAL,
PLUMBING, MECHANICAL, OR
FIRE SPRINKLER WORK
It should be known that this review shall
not relieve the applicant of their
responsibility to comply with the
requirements of the City of Aspen
Municipal Code. Pursuant to
Sec.26.104.050, any permit or approval
issued in error or otherwise not in
conformity with the requirements of this
Title, shall be void. Similarly, any permit
or approval issued in reliance upon or
as a result of, a materially false
statement or representation made in
the process of obtaining the permit or
development approval shall, likewise,
be void. Any person having received a
void or voidable permit or approval
shall not be relieved from having to
comply with all applicable terms and
conditions of this Title and the City shall
not be estopped from fully enforcing
same.
sophiev
05/18/2023ZONING
To verify fenestration U-factors, the following is
REQUIRED PRIOR TO GLAZING INSPECTION:
Factory built windows:
An NFRC label must be affixed to the window assembly and
verified at field inspection.
Site built windows:
A certificate of authorization from an NFRC authorized inspection
agency has been received and approved. Project specific NFRC
labels must be affixed to the units or a project specific NFRC
label certificate must be provided prior to field inspection.
Site built windows:
ASHRAE calculations were approved. To document the chain of
custody, an affidavit or other evidence from the manufacturer
confirming compliance with the calculations are required
prior to field inspection.
Site built windows:
A simulation by an NFRC–accredited lab in accordance with
NFRC-100 has been approved. Verification labels must be
affixed to the window units by an accredited independent
inspection agency or a certificate, affidavit or other evidence
from the manufacturer confirming compliance with the
NFRC-100 simulation or testing must be provided for
approval prior to inspection.
06/22/2023
jimp
RESIDENTIAL REFERENCES FROM 2009 IBC
CV/CS = crawl space ventilation sec. 1203.3. 18” x
24”access required 1209.1
EE = emergency escape required sec 1029
EU = enclosed usable space under stairs shall be 1-hr
construction or stair enclosure rating. No access from stair
enclosure.1009.6.3
RV = roof and rafter ventilation required 1203.2
A = Attic Access 20” x 30” 1209.2
SA = smoke alarm (NFPA 72) required sec 907.2.11.2
CO = carbon monoxide detector req. per Aspen Muni.
Code 8.15
SG = safety glazing required sec 2406
V = ventilation required sec 1203.4.2.1, IMC 402 & 403
bathroom mechanical ventilation req. per City
Ordinance 31 series 2011
GR = guards, 42” min ht, 4” max opening sec 1013
HR = handrails 34”-38” ht sec 1012
DS = Draft stopping / fire blocking 717
RD = Roof drainage 1503.4
RV = Roof Ventilation 1203.2
STC = Sound transmission class not less than 50 at
dwelling separations, sec 1207
SI = Stairway Illumination 1205.4
PD = protect against decay, sec 2304.11
REFERENCES FROM 2009 IMC
DE = clothes dryer exhaust, sec 504. Makeup air req’d if
over 200 CFM
AS = access and service space for maintenance req’d,
sec 306
MA = make up air required if hood exhausts greater than
400 CFM, sec 505.2
ET = exhausts terminate 3’ from prop line and openings,
10’ from intakes, 501.2.1
IT= intake openings 10’ from lot line & contaminant
sources (vents, streets), 401.4
D = fasten and seal all ductwork per 603.9
REFERENCES FROM 2009 IFGC
DV = direct vent req’d, sec 303.3
CA = combustion air not taken from bedrooms, bathrooms
or
storage sec 303.3
OD = outdoor appliances must be listed for outdoor use,
sec 303.6
REFERENCES FROM 2009 IECC
F = new or replacement glazing shall not exceed 0.35
U-Value, NFRC label required, sec 402.3.6
L = 50% of lamps in permanently installed lights must be
high efficacy, sec 404.1
SE = All exterior joints, cracks, holes to be caulked,
gasketed, sealed, sec 402.4
REFERENCES FROM 2011 NEC
EP = electric panel ‘happy space’ 30”x36”x78”, not in
storage, sec 110.26
0073-2023-BRES
Peter Carman
700 Ute Ave., 808
273718271002
APPLICATION ACCEPTED DATE: 2023-05-17 PERMIT NUMBER: 0073-2023-BRES
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT COVERSHEET
PROPERTY INFORMATION
ADDRESS: 700 UTE AVE 808 UNIT:
PARCEL ID: 273718271002 LEGAL DESCRIPTION: ASPEN ALPS NORTH
OWNER: CARMAN PETER
PERMIT CONTRACTOR: NW Extreme Installers, Inc.
DESCRIPTION OF WORK We will be replacing (2) windows in a like for like sizing manner, no structural modifications to be made.
Windows will be installed as a nail flange application and to be plumb, level and square. Flanges to be covered
with roll tape flashing and head flashing as required. All exterior trim to be caulked to siding and windows using
exterior grade caulking. Sealed to exterior.
USE OF BUILDING Single Family FIRE SPRINKLER REQUIRED?
CLASS OF WORK Residential FIRE SPRINKLER TYPE
BUILDING TYPE (IRC) REQUIRED SPECIAL
INSPECTIONS
CONSTRUCTION TYPE VA ENERGY CODE COMPLIANCE Prescriptive Table
OCCUPANCY GROUP (IBC) R-2 WORK CHANGES BUILDING
FOOTPRINT? No
CODE EDITIONS 2021 IBC TOTAL SPA SQ.FT.
OTHER CODE EDITIONS 2021 IEBC, 2021 IECC TOTAL SNOWMELT SQ.FT.
HISTORIC PROPERTY? No TOTAL POOL SQ.FT.
FIRE SPRINKLER EXISTING?
CALIX, JORGE
700 S UTE 806
ASPEN,CO 81611
Phone (970) 319-6874
Alt Phone (970) 319-6824
JCALIX@ASPENALPS.COM
PARCEL: 273718271001
We will be replacing (2) windows in a like for like sizing manner, no structural
modifications to be made. Windows will be installed as a nail flange application
and to be plumb, level and square. Flanges to be covered with roll tape flashing
and head flashing as required. All exterior trim to be caulked to siding and
windows using exterior grade caulking. Sealed to exterior.
2nd FLOOR
BED
BED
BED
BED
LIVING
BATH
BATH
BATH
BATH
STAIRSSTAIRSSTAIRS
HALL
WINDOW
64.75"X44.75"
S UTE AVE
NORTH
05/12/2023
sophiev
05/18/2023ZONING
F FRAMING CAVITIES ARE EXPOSED:
QUALITY INSULATION REQUIRED
finish materials are removed to expose
aming cavities in the thermal envelope,
hose cavities must be filled with insulation
nstalled to Grade I quality standard
CC/RESNET 301).
Ordinance 1, 2023
atts/loose fill: Insulation shall be closely
tted wiring, pipes, etc. and avoid
ubstantial gaps, voids or compression. No
more than 2% of the total insulated area
hall be compressed or contain gaps or
oids in the insulation. These areas shall
ot be compressed more
han 3/4 inch.
06/22/2023
jimp
700 Ute Ave Unit 808 | Windows to
be replaced like-for-like
05/12/2023
sophiev
05/18/2023ZONING
06/22/2023
jimp
Customer:(1905) LOWE'S OF GLENWOOD
SPRINGS, CO
215 WEST MEADOWS DRIVE
(970) 384-3940
PELLA
Quote #
Associate:
Phone:
Address:
GLENWOOD SPRINGS, CO 81601-
9223
JESUS BENAVIDES (1844972)
Jorge Calix
700 S UTE AVE # 206
777984865
(970) 319-6874
ASPEN, CO 81611
Store:
Address:
Phone:
Lowe's Custom Order Quote
Date Printed:5/3/2023
Pre-Tax Total:$6,836.60
Quote Name:
Labor Total:$0.00
Freight Total:$0.00
jcalix@aspenalps.comEmail:
4Item Total:
$6,836.60PreSavings Total:
Architect | Traditional 2-Wide Casement | 65 X
45 | Brown
Room Location: None Assigned
100-1 2 $6,698.76$3,349.38Architect | Traditional 2-Wide Casement | 65 X 45 |
Brown
191 days $3,349.38
Product Warranty
Line #Item Summary Pre-Tax TotalWas Price Now Price Quantity Total SavingsProduction Time
100-2 2 $137.84$68.92Screen Full Screen Bright White InView 191 days $68.92
Line #Item Summary Pre-Tax TotalWas Price Now Price Quantity Total SavingsProduction Time
End Line 100 Descriptions
Begin Line 100 Descriptions
A1: Traditional
Non-Standard SizeNon-Standard Size Left
Casement. Frame Size: 32 1/2 X 45. Architect
Series. Northern
Standard
Clad
Pine
5"
3 11/16". Painted
Standard Enduraclad
Brown. Bright White Paint Interior. Ogee
Ogee
Standard. Glass: Insulated Dual Low-E
AdvancedComfort Low-E Insulating Glass Argon
High Altitude. Side Pivot Hardware
Fold-Away Crank
White
No Window Opening Control Device
No Limited Opening Hardware
No Integrated Sensor. Full Screen
Bright White
InView™. No. Combination U-Factor 0.25
U-Factor 0.25
Combination SHGC 0.27
SHGC 0.27
VLT 0.49
CPD PEL-N-11-24325-00001
Satisfied Energy Star Zones Northern,North
Central
Performance Class CW
PG 50
Combination Positive DP Rating N/A
Calculated Positive DP Rating 50
Combination Negative DP Rating N/A
Calculated Negative DP Rating 50
FPAS FL31311
Year Rated 11
Egress Meets Typical 5.7 sqft (E) (United States
Only). Remake: No
In-Store Pick-up
EA
04/18/2023
False
True
877-473-5527
. 191 Days. 949819
WTS Pella Arch Window. 33070.
Grille: No Grille
MV1: FactoryMull
Standard Joining Mullion
Frame To Frame Width- 0"
Mull Design Pressure- 20
B1: Traditional
Non-Standard SizeNon-Standard Size Fixed
Sash Set. Frame Size: 32 1/2 X 45. Architect
Series. Northern
Standard
Clad
Pine
5"
3 11/16". Painted
Standard Enduraclad
Brown. Bright White Paint Interior. Ogee
Ogee
Standard. Glass: Insulated Dual Low-E
AdvancedComfort Low-E Insulating Glass Argon
High Altitude. No. Combination U-Factor 0.25
U-Factor 0.23
Combination SHGC 0.27
SHGC 0.30
VLT 0.56
CPD PEL-N-1-59323-00001
Satisfied Energy Star Zones Northern,North
Central
Performance Class CW
PG 50
Combination Positive DP Rating N/A
Calculated Positive DP Rating 50
Combination Negative DP Rating N/A
Calculated Negative DP Rating 50
Year Rated 11. Remake: No
In-Store Pick-up
EA
04/18/2023
False
True
877-473-5527
. 191 Days. 949819
WTS Pella Arch Window. 33070.
Grille: No Grille
Wrapping Information: Foldout Fins
Factory Applied
5 9/16"
6 7/8"
Standard Four Sided Jamb Extension
Factory Applied
Pella Recommended Clearance
Perimeter Length = 220".
---- Line 100-1 ----
Screen Full Screen Bright White InView
---- Line 100-2 ----