Loading...
HomeMy WebLinkAboutFile Documents.700 Ute Ave.0073-2023-BRES (4)SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK It should be known that this review shall not relieve the applicant of their responsibility to comply with the requirements of the City of Aspen Municipal Code. Pursuant to Sec.26.104.050, any permit or approval issued in error or otherwise not in conformity with the requirements of this Title, shall be void. Similarly, any permit or approval issued in reliance upon or as a result of, a materially false statement or representation made in the process of obtaining the permit or development approval shall, likewise, be void. Any person having received a void or voidable permit or approval shall not be relieved from having to comply with all applicable terms and conditions of this Title and the City shall not be estopped from fully enforcing same. sophiev 05/18/2023ZONING To verify fenestration U-factors, the following is REQUIRED PRIOR TO GLAZING INSPECTION: Factory built windows: An NFRC label must be affixed to the window assembly and verified at field inspection. Site built windows: A certificate of authorization from an NFRC authorized inspection agency has been received and approved. Project specific NFRC labels must be affixed to the units or a project specific NFRC label certificate must be provided prior to field inspection. Site built windows: ASHRAE calculations were approved. To document the chain of custody, an affidavit or other evidence from the manufacturer confirming compliance with the calculations are required prior to field inspection. Site built windows: A simulation by an NFRC–accredited lab in accordance with NFRC-100 has been approved. Verification labels must be affixed to the window units by an accredited independent inspection agency or a certificate, affidavit or other evidence from the manufacturer confirming compliance with the NFRC-100 simulation or testing must be provided for approval prior to inspection. 06/22/2023 jimp RESIDENTIAL REFERENCES FROM 2009 IBC CV/CS = crawl space ventilation sec. 1203.3. 18” x 24”access required 1209.1 EE = emergency escape required sec 1029 EU = enclosed usable space under stairs shall be 1-hr construction or stair enclosure rating. No access from stair enclosure.1009.6.3 RV = roof and rafter ventilation required 1203.2 A = Attic Access 20” x 30” 1209.2 SA = smoke alarm (NFPA 72) required sec 907.2.11.2 CO = carbon monoxide detector req. per Aspen Muni. Code 8.15 SG = safety glazing required sec 2406 V = ventilation required sec 1203.4.2.1, IMC 402 & 403 bathroom mechanical ventilation req. per City Ordinance 31 series 2011 GR = guards, 42” min ht, 4” max opening sec 1013 HR = handrails 34”-38” ht sec 1012 DS = Draft stopping / fire blocking 717 RD = Roof drainage 1503.4 RV = Roof Ventilation 1203.2 STC = Sound transmission class not less than 50 at dwelling separations, sec 1207 SI = Stairway Illumination 1205.4 PD = protect against decay, sec 2304.11 REFERENCES FROM 2009 IMC DE = clothes dryer exhaust, sec 504. Makeup air req’d if over 200 CFM AS = access and service space for maintenance req’d, sec 306 MA = make up air required if hood exhausts greater than 400 CFM, sec 505.2 ET = exhausts terminate 3’ from prop line and openings, 10’ from intakes, 501.2.1 IT= intake openings 10’ from lot line & contaminant sources (vents, streets), 401.4 D = fasten and seal all ductwork per 603.9 REFERENCES FROM 2009 IFGC DV = direct vent req’d, sec 303.3 CA = combustion air not taken from bedrooms, bathrooms or storage sec 303.3 OD = outdoor appliances must be listed for outdoor use, sec 303.6 REFERENCES FROM 2009 IECC F = new or replacement glazing shall not exceed 0.35 U-Value, NFRC label required, sec 402.3.6 L = 50% of lamps in permanently installed lights must be high efficacy, sec 404.1 SE = All exterior joints, cracks, holes to be caulked, gasketed, sealed, sec 402.4 REFERENCES FROM 2011 NEC EP = electric panel ‘happy space’ 30”x36”x78”, not in storage, sec 110.26 0073-2023-BRES Peter Carman 700 Ute Ave., 808 273718271002 APPLICATION ACCEPTED DATE: 2023-05-17 PERMIT NUMBER: 0073-2023-BRES COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT COVERSHEET PROPERTY INFORMATION ADDRESS: 700 UTE AVE 808 UNIT: PARCEL ID: 273718271002 LEGAL DESCRIPTION: ASPEN ALPS NORTH OWNER: CARMAN PETER PERMIT CONTRACTOR: NW Extreme Installers, Inc. DESCRIPTION OF WORK We will be replacing (2) windows in a like for like sizing manner, no structural modifications to be made. Windows will be installed as a nail flange application and to be plumb, level and square. Flanges to be covered with roll tape flashing and head flashing as required. All exterior trim to be caulked to siding and windows using exterior grade caulking. Sealed to exterior. USE OF BUILDING Single Family FIRE SPRINKLER REQUIRED? CLASS OF WORK Residential FIRE SPRINKLER TYPE BUILDING TYPE (IRC) REQUIRED SPECIAL INSPECTIONS CONSTRUCTION TYPE VA ENERGY CODE COMPLIANCE Prescriptive Table OCCUPANCY GROUP (IBC) R-2 WORK CHANGES BUILDING FOOTPRINT? No CODE EDITIONS 2021 IBC TOTAL SPA SQ.FT. OTHER CODE EDITIONS 2021 IEBC, 2021 IECC TOTAL SNOWMELT SQ.FT. HISTORIC PROPERTY? No TOTAL POOL SQ.FT. FIRE SPRINKLER EXISTING? CALIX, JORGE 700 S UTE 806 ASPEN,CO 81611 Phone (970) 319-6874 Alt Phone (970) 319-6824 JCALIX@ASPENALPS.COM PARCEL: 273718271001 We will be replacing (2) windows in a like for like sizing manner, no structural modifications to be made. Windows will be installed as a nail flange application and to be plumb, level and square. Flanges to be covered with roll tape flashing and head flashing as required. All exterior trim to be caulked to siding and windows using exterior grade caulking. Sealed to exterior. 2nd FLOOR BED BED BED BED LIVING BATH BATH BATH BATH STAIRSSTAIRSSTAIRS HALL WINDOW 64.75"X44.75" S UTE AVE NORTH 05/12/2023 sophiev 05/18/2023ZONING F FRAMING CAVITIES ARE EXPOSED: QUALITY INSULATION REQUIRED finish materials are removed to expose aming cavities in the thermal envelope, hose cavities must be filled with insulation nstalled to Grade I quality standard CC/RESNET 301). Ordinance 1, 2023 atts/loose fill: Insulation shall be closely tted wiring, pipes, etc. and avoid ubstantial gaps, voids or compression. No more than 2% of the total insulated area hall be compressed or contain gaps or oids in the insulation. These areas shall ot be compressed more han 3/4 inch. 06/22/2023 jimp 700 Ute Ave Unit 808 | Windows to be replaced like-for-like 05/12/2023 sophiev 05/18/2023ZONING 06/22/2023 jimp Customer:(1905) LOWE'S OF GLENWOOD SPRINGS, CO 215 WEST MEADOWS DRIVE (970) 384-3940 PELLA Quote # Associate: Phone: Address: GLENWOOD SPRINGS, CO 81601- 9223 JESUS BENAVIDES (1844972) Jorge Calix 700 S UTE AVE # 206 777984865 (970) 319-6874 ASPEN, CO 81611 Store: Address: Phone: Lowe's Custom Order Quote Date Printed:5/3/2023 Pre-Tax Total:$6,836.60 Quote Name: Labor Total:$0.00 Freight Total:$0.00 jcalix@aspenalps.comEmail: 4Item Total: $6,836.60PreSavings Total: Architect | Traditional 2-Wide Casement | 65 X 45 | Brown Room Location: None Assigned 100-1 2 $6,698.76$3,349.38Architect | Traditional 2-Wide Casement | 65 X 45 | Brown 191 days $3,349.38 Product Warranty Line #Item Summary Pre-Tax TotalWas Price Now Price Quantity Total SavingsProduction Time 100-2 2 $137.84$68.92Screen Full Screen Bright White InView 191 days $68.92 Line #Item Summary Pre-Tax TotalWas Price Now Price Quantity Total SavingsProduction Time End Line 100 Descriptions Begin Line 100 Descriptions A1: Traditional Non-Standard SizeNon-Standard Size Left Casement. Frame Size: 32 1/2 X 45. Architect Series. Northern Standard Clad Pine 5" 3 11/16". Painted Standard Enduraclad Brown. Bright White Paint Interior. Ogee Ogee Standard. Glass: Insulated Dual Low-E AdvancedComfort Low-E Insulating Glass Argon High Altitude. Side Pivot Hardware Fold-Away Crank White No Window Opening Control Device No Limited Opening Hardware No Integrated Sensor. Full Screen Bright White InView™. No. Combination U-Factor 0.25 U-Factor 0.25 Combination SHGC 0.27 SHGC 0.27 VLT 0.49 CPD PEL-N-11-24325-00001 Satisfied Energy Star Zones Northern,North Central Performance Class CW PG 50 Combination Positive DP Rating N/A Calculated Positive DP Rating 50 Combination Negative DP Rating N/A Calculated Negative DP Rating 50 FPAS FL31311 Year Rated 11 Egress Meets Typical 5.7 sqft (E) (United States Only). Remake: No In-Store Pick-up EA 04/18/2023 False True 877-473-5527 . 191 Days. 949819 WTS Pella Arch Window. 33070. Grille: No Grille MV1: FactoryMull Standard Joining Mullion Frame To Frame Width- 0" Mull Design Pressure- 20 B1: Traditional Non-Standard SizeNon-Standard Size Fixed Sash Set. Frame Size: 32 1/2 X 45. Architect Series. Northern Standard Clad Pine 5" 3 11/16". Painted Standard Enduraclad Brown. Bright White Paint Interior. Ogee Ogee Standard. Glass: Insulated Dual Low-E AdvancedComfort Low-E Insulating Glass Argon High Altitude. No. Combination U-Factor 0.25 U-Factor 0.23 Combination SHGC 0.27 SHGC 0.30 VLT 0.56 CPD PEL-N-1-59323-00001 Satisfied Energy Star Zones Northern,North Central Performance Class CW PG 50 Combination Positive DP Rating N/A Calculated Positive DP Rating 50 Combination Negative DP Rating N/A Calculated Negative DP Rating 50 Year Rated 11. Remake: No In-Store Pick-up EA 04/18/2023 False True 877-473-5527 . 191 Days. 949819 WTS Pella Arch Window. 33070. Grille: No Grille Wrapping Information: Foldout Fins Factory Applied 5 9/16" 6 7/8" Standard Four Sided Jamb Extension Factory Applied Pella Recommended Clearance Perimeter Length = 220". ---- Line 100-1 ---- Screen Full Screen Bright White InView ---- Line 100-2 ----