HomeMy WebLinkAboutFile Documents.711 S Galena St.0036-2023-BRES (9)SMOKE ALARMS AND
CARBON MONOXIDE
DETECTORS REQUIRED
THROUGHOUT DWELLING
UNIT PER CITY OF ASPEN
MUNICIPAL CODE 8.15
These plans must be kept at the
building site or inspection
delays may occur. Construction
shall conform to these plans. All
changes shall be approved by
the building official.
Field Plan Set Must Be Printed In Color
SEPARATE PERMITS ARE
REQUIRED FOR ELECTRICAL,
PLUMBING, MECHANICAL, OR
FIRE SPRINKLER WORK
It should be known that this review shall
not relieve the applicant of their
responsibility to comply with the
requirements of the City of Aspen
Municipal Code. Pursuant to
Sec.26.104.050, any permit or approval
issued in error or otherwise not in
conformity with the requirements of this
Title, shall be void. Similarly, any permit
or approval issued in reliance upon or
as a result of, a materially false
statement or representation made in
the process of obtaining the permit or
development approval shall, likewise,
be void. Any person having received a
void or voidable permit or approval
shall not be relieved from having to
comply with all applicable terms and
conditions of this Title and the City shall
not be estopped from fully enforcing
same.
0036-2023-BRES
James Anthony Delaney
711 S. Galena St. 16D
273718279012
UNIT 16D
BUILDING | UNIT RELATIONSHIP
A ELEVATION
PARKING
TEMPORARY TRASH
REMOVAL IN TRUCK
UNIT 16D
Minor CMP - Location of Parking/Trash Removal
Existing Rated Wall Assembly in Kitchen (Demising
Wall)
General Electrical Requirements
Any areas affected by the renovation must be brought
up to the current electrical code including:
tamperproof receptacles (NEC 406.12),
ground-fault circuit interrupter protection (NEC 210.8),
arc-fault protection (NEC 210.12),
receptacle spacing (NEC 210.52) etc.
Any recessed light fixtures
in contact with insulation
must be IC rated.
FIRE RATED HATS REQUIRED
Where floor/ceiling or roof/ceiling
assemblies are required to have a
fire-resistive rating, recessed fixtures shall
be installed such that the required fire
resistance will not be reduced (IBC 714.4.2)
READ THIS OR FAIL YOUR INSPECTION!
Furred & Dropped Ceilings, Soffits, and Walls
20015 IBC 803.13
This applies to the attachment of finishes or furring to any
assemblies that are required to be either fire-rated or
non-combustible and is separate from the fire-rated
assembly requirement.
Walls, Ceilings & Soffits: If furred 1 ¾ inches or
less, do one of the following:
4.Fill spaces with Class A material.
5.Fill spaces with inorganic or non-combustible material.
6.Fire block 8 feet in all directions.
Walls: If set out (furred) greater than 1 ¾ inches,
do one of the following:
4.Use a Class A finish material (such as drywall).
5.Use non-combustible framing.
6.Protect both sides with fire sprinklers.
Ceilings & Soffits: If dropped (furred) greater
than 1 ¾ inches:
Framing members, hangers, and other assembly
members must be non-combustible. You may not
use wood.
In Type III and V construction only, you may use fire
retardant treated wood or non-combustible framing.
Dwelling Separation Required - 2015 IBC
-708 Fire Partitions, 711 Horizontal Assemblies:
Walls and floor/ceilings separating dwelling units shall have a fire-resistance
rating of at least 1 hour. Walls shall extend from the top of the floor assembly
below to the underside of the floor or roof slab or deck above or to the
fire-resistance-rated floor/ceiling assembly above.
-714: Penetrations must be protected by a through-penetration firestop
system. Recessed fixtures shall not reduce the required fire resistance by use
of a listed fixture, a listed firehood, or a drywall assembly meeting the required
fire resistance. Exhaust fans require ceiling radiation damper.
-1207 Sound Transmission: Separating walls and floor/ceilings shall have an
STC rating of at least 50. Floor/ceilings shall have an IIC rating of at least 50.
s
a
sound
transmission
ASTM
E2179
Delta IIC 22
Airborne
sound
transmission
ASTM
E90
STC 55
Impact sound
transmission
ASTM
E492
IIC 50
Sound Reduction Ratings:
Sound Transmission Rating for flooring
2015 IBC Residential Code References
CO Carbon monoxide detector required per Aspen Municipal Code 8.15
SA Smoke alarm per NFPA 72 required, 2015 IBC 907.2.11
2015 IBC 601 Fire Resistive Requirements for
Type of Construction: ____
Primary Structural Frame: ____hr
(columns, beams, girders, etc)
Exterior Bearing Walls: ____hr
Interior Bearing Walls: ____hr
Floors/Ceilings: ____hr
Roof : ____hr
Unless noted otherwise for occupancy separation or fire
separation distance.