Loading...
HomeMy WebLinkAboutFile Documents.936 W Francis St.0093-2023-BRES (9)SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK It should be known that this review shall not relieve the applicant of their responsibility to comply with the requirements of the City of Aspen Municipal Code. Pursuant to Sec.26.104.050, any permit or approval issued in error or otherwise not in conformity with the requirements of this Title, shall be void. Similarly, any permit or approval issued in reliance upon or as a result of, a materially false statement or representation made in the process of obtaining the permit or development approval shall, likewise, be void. Any person having received a void or voidable permit or approval shall not be relieved from having to comply with all applicable terms and conditions of this Title and the City shall not be estopped from fully enforcing same. 07/14/2023 magdad 07/21/2023ZONING 07/14/2023 magdad 07/21/2023ZONING Residential Design Standards Exemption Form Exemption Applies Notes Remodel of a structure where the alterations proposed change the exterior of the building, but are not addressed by any of the Residential Design Standards Residential unit within a mixed-use building Designated historic resource listed on the Aspen Inventory of Historic Landmark Sites and Structures Has already received a board design approval Disclaimer: This exemption is only valid for the attached scope of work. If the project scope ex- pands to include work subject to Residential Design Standards, the applicant shall be required to apply for an Administrative Compliance Review. Address: Parcel ID: Zone District/PD: Representative: Email: Phone: Scope of Work: Reviewed by: (Project plans/elevations attached) 936 W. Francis 2735-123-00-013 Medium Density Residential (R-6) Carrie McKellip | Renewal by Andersen cmckellip@renewalcolorado.com 970.535.6078 Replacing existing street facing windows like-for-like (Same dimensions, locations, openings, etc.) Kevin Rayes Digitally signed by Kevin Rayes Date: 2023.07.03 15:40:09 -06'00' Like-for-like improvements are exempt from RDS provisions. 4 07/14/2023 Window- 101 & 102 07/14/2023 Window 103 07/14/2023 F F F 2021 IBC Code References L 100% of lamps in permanently installed lights must be high efficacy, Ordinance 1, 2023. AS Access and service space for maintenance required, 2021 IMC 306 CO Carbon monoxide detector required per Aspen Municipal Code 8.15 DE Clothes dryer exhaust, 2021 IMC 504. Makeup air required if over 200 CFM SE Continuous air barrier required; all exterior joints, cracks, and holes to be caulked, gasketed, sealed, Ordinance 1, 2023 DV Direct vent sealed combustion required, Ordinance 1, 2023 EP Electric panel happy space: 30in x 36in x 78in, not in storage, NEC 110.26 EE Emergency escape and rescue opening required 2021 IBC 1031 ET Exhausts terminate 3ft from prop line and openings, 10ft from intakes, 2021 IMC 501.3.1 GR Guards, 42in min high, 4in max opening. Guards within dwelling unit 36in min high 2021 IBC 1015 HR Handrails 34in-38in high, 2021 IBC 1014 IT Intake openings 10ft from lot line & contaminant sources (vents, streets), 2021 IMC 401.4 MA Make up air required if hood exhausts greater than 400 CFM, 2021 IMC 505.4 V Mechanical ventilation required, Ordinance 1, 2023 F New or replacement fenestration in existing residential buildings shall not exceed 0.28 U-factor, NFRC label required, Ordinance 1, 2023 SG Safety glazing required, 2021 IBC 2406 SA Smoke alarm per NFPA 72 required, 2021 IBC 907.2.11 WFP Window fall protection- operable window less than 24in AFF and greater than 72in above exterior grade: use opening control device listed to ASTM F2090, 2021 IBC 1015.8 08/02/2023 linzhid 0093-2023-BRES SHARP DESIGNS INC 936 W FRANCIS ST 273512300013