Loading...
HomeMy WebLinkAboutFile Documents.803 E Durant Ave.0128-2022-BRES (13)SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK It should be known that this review shall not relieve the applicant of their responsibility to comply with the requirements of the City of Aspen Municipal Code. Pursuant to Sec.26.104.050, any permit or approval issued in error or otherwise not in conformity with the requirements of this Title, shall be void. Similarly, any permit or approval issued in reliance upon or as a result of, a materially false statement or representation made in the process of obtaining the permit or development approval shall, likewise, be void. Any person having received a void or voidable permit or approval shall not be relieved from having to comply with all applicable terms and conditions of this Title and the City shall not be estopped from fully enforcing same. luisp 12/27/2022ZONING 0128-2022-BRES Peter R. Dirkes 803 E. Durant Ave. #9 273718258006 September 5, 2022 Peter R. Dirkes 324 Foxwood Lane Mill Neck, New York 11765 (516) 816-1307 peter.dirkes@gmail.com RE: Le Clairvaux, Unit 9 Remodel 803 East Durant Avenue Aspen, Colorado ESD Project #: 22.128C Peter, As requested, we have reviewed the proposed interior remodel at the location noted above. Our review is based upon existing and proposed architectural drawings provided by BG Architecture + Design, dated July 29, 2022. The current proposed scope of work includes modifications to the interior walls and ceiling structure. Once demolition can begin, the wall and ceiling finishes in these areas, shall be at least partially removed in order to verify the potential effects to the existing structure. We shall be contacted to visually observe the conditions and will then work to define the structural impact of the proposed. This shall be done prior to proceeding with the removal or modification of any framing members, while also allowing sufficient time for the scope of structural engineering to be defined and completed. Please note, no interior partition walls nor ceiling framing shall be removed or modified prior to our observation. Furthermore, if any drywall or other finishes are showing signs of movement or moisture, such as cracking, bubbling, discoloration or spalling, we should be notified to observe conditions prior to the removal of any finishes. The proposed structural modifications may require an analysis of both the gravity and lateral systems, tracing gravity and lateral load paths through the building, possibly affecting and requiring structural work in areas of the building outside of the proposed architectural scope. Please note, that verifications and subsequent recommendations may have a significant impact on the project direction and schedule. Should you have any further questions regarding this matter, please feel free to contact our office. We look forward to working with you through the completion of your remodel. Sincerely, Evolve Structural Design LLC Sara Mickus, P.E. Principal 09/05/22 11/09/202201/23/2023 sami GSPublisherVersion 0.0.100.100 N DRAWING TITLE: Drawn by: SYNERGY C.M.D. Project No.: CONSULTANTS: Scale: HCP CONCEPT. REV. HCP FINAL REV. PERMIT SET DATE OF PUBLICATION PARCEL ID: 27 37 18 25 8005 SITE ADRESS: 803 EAST DURANT AVENUE UNIT 9 ASPEN COLORADO, 81611 bg ARCHITECTURE & DESIGN 111H AABC Aspen, Co 81611 Barry Gereb T. (970) 948 6709 OWNER: PETER DIRKES 324 FOXWOOD LANE MILL NECK, NY 11765 T. (516) 816 1037 SYNERGY C. M. D. 16 Kearns Rd Snowmass, Co 81615 Rolf Fraser T. (970) 205 9320 SITE PLAN proposed C 1.3 LEGEND: 10YD DUMPSTER 7.5FT X 14 FT PORTABLE RESTROOM 45IN X 45IN MATERIAL STORAGE BUILDING INTERIOR REMODEL, UNIT 9 NOTE: NO IMPACT TO TRAFFIC SCALE 1:20FT 11/09/202201/23/2023 sami APPLICATION ACCEPTED DATE: 2022-11-18 PERMIT NUMBER: 0128-2022-BRES COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT COVERSHEET PROPERTY INFORMATION ADDRESS: 803 E DURANT AVE 9 UNIT: PARCEL ID: 273718258006 LEGAL DESCRIPTION: LE CLAIRVAUX TOWNHOUSE OWNER: DIRKES PETER R PERMIT CONTRACTOR: DESCRIPTION OF WORK Interior Scope: Full interior remodel including minor wall relocations, removal of ceiling beams and all drywall, replace electrical panel, devices and lighting, replace all cabinetry, replace all interior finishes, replace all plumbing fittings, replace existing wood burning fireplace with gas appliance fireplace Exterior Scope: Replace skylights in existing locations, add new gas appliance roof top vent USE OF BUILDING Multi-Family FIRE SPRINKLER REQUIRED? No CLASS OF WORK Residential FIRE SPRINKLER TYPE BUILDING TYPE (IRC) REQUIRED SPECIAL INSPECTIONS CONSTRUCTION TYPE VA ENERGY CODE COMPLIANCE Prescriptive Table OCCUPANCY GROUP (IBC) R-2 WORK CHANGES BUILDING FOOTPRINT? No CODE EDITIONS 2015 IBC TOTAL SPA SQ.FT. OTHER CODE EDITIONS 2015 IEBC, 2015 IMC, 2020 NEC TOTAL SNOWMELT SQ.FT. HISTORIC PROPERTY? No TOTAL POOL SQ.FT. FIRE SPRINKLER EXISTING? No INSTALLATION INSTRUCTIONS REQUIRED ON SITE AT TIME OF INSPECTION RESIDENTIAL REFERENCES FROM 2015 IBC CV/CS = crawl space ventilation sec. 1203.4. 18” x 24” access required 1209.1 EE = emergency escape required sec 1030 EU = enclosed usable space under stairs shall be 1-hr construction or stair enclosure rating. No access from stair enclosure. ½” gypsum permitted for stairs inside a single dwelling unit. 1011.7.3. RV = roof and rafter ventilation required 1203.2 A = Attic Access 20” x 30” 1209.2 SA = smoke alarm (NFPA 72) required sec 907.2.11 CO = carbon monoxide detector req. per Aspen Municipal Code 8.15 SG = safety glazing required sec 2406 V = mechanical ventilation required sec 1203.1 & IMC 403 (bath fans and whole house ventilation) GR = guards, 42” min ht, 4” max opening. Guards within dwelling unit 36” min ht sec 1015 HR = handrails 34”-38” ht sec 1014 DS = Draft stopping / fire blocking 718 RD = Roof drainage 1503.4 STC = Sound transmission class not less than 50 at dwelling separations, sec 1207 SI = Stairway Illumination 1205.4 PD = protect against decay, sec 2304.12 REFERENCES FROM 2015 IMC DE = clothes dryer exhaust, sec 504. Makeup air req’d if over 200 CFM AS = access and service space for maintenance req’d, sec 306 MA = make up air required if hood exhausts greater than 400 CFM, sec 505.2 ET = exhausts terminate 3’ from prop line and openings, 10’ from intakes, 501.3.1 IT= intake openings 10’ from lot line & contaminant sources (vents, streets), 401.4 D = fasten and seal all ductwork per 603.9 REFERENCES FROM 2015 IFGC DV = direct vent req’d, sec 303.3 CA = combustion air not taken from bedrooms, bathrooms or storage sec 303.3 OD = outdoor appliances must be listed for outdoor use, sec 303.6 REFERENCES FROM 2015 IECC F = new or replacement fenestration shall not exceed 0.28 U-factor, NFRC label required, Ordinance 40, 2016 L = 75% of lamps in permanently installed lights must be high efficacy, sec R404.1 SE = Continuous air barrier required; all exterior joints, cracks, and holes to be caulked, gasketed, sealed, table R402.4.1.1 REFERENCES FROM 2014 NEC EP = electric panel 'happy space' 30"x36"x78", not in storage, sec 110.26 General Electrical Requirements Any areas affected by the renovation must be brought up to the current electrical code including: tamperproof receptacles (NEC 406.12), ground-fault circuit interrupter protection (NEC 210.8), arc-fault protection (NEC 210.12), receptacle spacing (NEC 210.52) etc. Any recessed light fixtures in contact with insulation must be IC rated. Recessed luminaires installed in building thermal envelope shall be sealed and IC-rated – IECC sec R402.4.5 75% of lamps in permanently installed light fixtures shall be high efficacy - IECC R404.1 CEILING RADIATION DAMPERS REQUIRED Ducts and air transfer openings penetrating the ceiling of a fire rated ceiling assembly must be protected with a listed ceiling radiation damper. This includes bathroom exhaust fans. (IBC 717.6.2) FIRE RATED HATS REQUIRED Where floor/ceiling or roof/ceiling assemblies are required to have a fire-resistive rating, recessed fixtures shall be installed such that the required fire resistance will not be reduced (IBC 714.4.2)2015 IBC 601 Fire Resistive Requirements for Type of Construction: ____ Primary Structural Frame: ____hr (columns, beams, girders, etc) Exterior Bearing Walls: ____hr Interior Bearing Walls: ____hr Floors/Ceilings: ____hr Roof : ____hr Unless noted otherwise for occupancy separation or fire separation distance. VA 1 1 1 1 1 02/23/ 2 0 2 3 sami 2420 Grenoble Road Richmond, VA 23294 Toll Free: 800-782-5742 For every environment of your life. 02/23/ 2 0 2 3 sami 1 OWNER’S MANUAL 50-3624 WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Installation and service must be performed by a qualified installer, service agency or the gas supplier. Version Française: www.enviro.com/fr.html C#4001609WARRANTY REGISTRATIONenviro.com/warrantyG39G DIRECT VENT FIREPLACE - NOVA CERTIFIED TO: ANSI Z21.88 / CSA 2.33 VENTED GAS FIREPLACE HEATERS CSA 2.17 GAS FIRED APPLIANCES FOR HIGH ALTITUDES 11/09/202201/23/2023 sami