Loading...
HomeMy WebLinkAboutFile Documents.300 S Spring St.0054-2020-BCOM (13)The City of Aspen These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK 12/01/2020 sophiev NO EXTERIOR LIGHTING IN SCOPE OF WORK. SEPERATE PERMIT IS REQUIRED FOR ANY SIGNAGE COMcheck Software Version 4.1.1.0 Interior Lighting Compliance Certificate Project Title: 2015 IECC Project Type:Alteration Construction Site: 300 SPRING STREET STE 200 ASPEN, CO 81611 Owner/Agent: DAVID ROSENFELD CCA 640 E HYMAN AVE ASPEN, CO 81611 9709255590 DAVIDR@CUNNIFFE.COM Designer/Contractor: STANTON HUMPHRIES AEC 9707488520 STAN@AEC-VAIL.COM Project Information Energy Code: 300 SPRING STREET STE 200 Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) 1-OFFICE (Common Space Types:Office - Open Plan)785 0.98 769 769Total Allowed Watts = Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures OFFICE ( Common Space Types:Office - Open Plan 785 sq.ft.) LED 1: A: DOWNLIGHT: Other:1 35 13 455 LED 2: C: VANITY LIGHT: Other:1 1 20 20 LED 3: L: LINEAR LED DRIVERS: Other:1 3 96 288 763Total Proposed Watts = Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Interior Lighting PASSES Project Title: Data filename: 300 SPRING STREET STE 200 P:\Current Projects\20067.00 - 300 Spring Street - Hanover Office Remodel\Calculations\COMcheck\300 SPRING LIGHTING COMCHECK.cck 12/23/20Report date: 51 ofPage STANTON HUMPHRIES, PE 12/23/20 01/07/2021 bonniem 0054-2020-BCOM CJAR LLC 300 S Spring St 200 273718227116 2015 IBC 601 Fire Resistive Requirements for Type of Construction: _VB_ Primary Structural Frame: _0___hr (columns, beams, girders, etc) Exterior Bearing Walls: __0__hr Interior Bearing Walls: __0__hr Floors/Ceilings: _0___hr Roof : _0___hr Unless noted otherwise for occupancy separation or fire separation distance. COMMERCIAL REFERENCES FROM 2015 IBC EU = enclosed usable space under stairs shall be 1-hr construction or stair enclosure rating. No access from stair enclosure.1011.7.3 SG = safety glazing required sec 2406 V = ventilation required, including from bathrooms. sec 1203.1, IMC 402 & 403 GR = guards, 42” min ht, 4” max opening sec 1015 HR = handrails 34”-38” ht sec 1014 AS = risers shall be solid in accessible egress stairs sec 1011.5.5.3 DS = Draft stopping / fire blocking 718 RD = Roof drainage 1503.4 STC = Sound transmission class not less than 50 at dwelling separations, sec 1207 PD = protect against decay, sec 2304.12 REFERENCES FROM 2015 IMC AS = access and service space for maintenance req’d, sec 306 MA = kitchen hood make up air required, sec 508 ET = exhausts terminate 3’ from prop line and openings, 10’ from intakes, 501.3.1 IT= intake openings 10’ from lot line & contaminant sources (vents, streets), 401.4 D = fasten and seal all ductwork per 603.9 REFERENCES FROM 2015 IFGC CA = combustion air not taken from bathrooms or storage, sec 303.3 REFERENCES FROM 2015 IECC F = new or replacement glazing U factors may not exceed: Fixed fenestration: U 0.29 Operable fenestration: U 0.37 Entrance doors: U 0.77 -Must have NFRC label or ASHRAE calcs, sec C402.4 REFERENCES FROM 2014 NEC EP = electric panel ‘happy space’ 30”x36”x78”, not in storage, sec 110.26 FIRE SPRINKLERS REQUIRED