HomeMy WebLinkAboutFile Documents.617 W Bleeker St.0062-2019-BRES (42)MEDIA ROOM
001
PDR
002
SPORTS COURT
003
WORKOUT ROOM
009
SAUNA
008
STORAGE
007
GUEST BEDROOM
010
GUEST
BATHROOM
011
STORAGE
005
LAUNDRY ROOM
004
MECHANICAL ROOM
006
FC
5
H
5
FC
2
H
2
FC
3
H
3
EF
1
BL
2
BL
1
EF
1
EF
1
S S
S S
S
S
S
S
WASHER
DRYER
SUMP PUMP
GFCI
GFCI
44"
REF
J
F REFERENCE
ELEVATOR
SUBMITTAL
PB - PANEL
BASEMENT
J CAB
PB-3, PARTIAL
WASHER
DRYER
PB-1
PB-2
PB-3, PARTIAL
PB-4
PB-6,8
PB-5
PB-7
PB-9
PB-10 PB-11
PB-12,14
PB-13
PB-15
PB-16,18 PB-17
PB-19
GYM EQP
GYM EQPPB-20
PB-22
PB-24
PB-21PB-54
PB-53
PB-52
PB-51 PB-50 PB-49
PB-47
PB-48
PB-23
GFCI
GFCI
GFCI
GENERAL NOTES:
1.ALL 120V RECEPTACLES SHALL BE TAMPER RESISTANT.
2.ALL 120V 20A BREAKERS SHALL BE ARC FAULT TYPE.
3.EXTERIOR RECEPTACLES SHALL HAVE IN USE COVERS & BE WEATHER
RESISTANT.
4.ALL EQUIPMENT REQUIRES A DISCONNECT. IF EQUIPMENT DOES NOT
PLUG IN, PROVIDE A DISCONNECT.
5.EC & GC TO COORDINATE FOR LOCATION OF ELECTRICAL PANELS.
6.TYPICAL VALUES HAVE BEEN USED FOR A RESIDENTIAL SPA, ELEVATOR,
KITCHEN EQUIPMENT, ETC. VERIFY NAMEPLATE DATA WITH THE
OVERCURRENT PROTECTION USED IN DESIGN BEFORE ENERGIZING ANY
EQUIPMENT.
7.4800VA HAS BEEN PROVIDED FOR FUTURE GUTTER SNOW MELT.
8.2VA PER SQ FT ASSUMED FOR LIGHTING.
9.POWER BATHROOM EXHAUST FANS FROM LIGHTING CIRCUIT.
10.EC & GC TO COORDINATE WITH ELECTRICAL UTILITY FOR TRANSFORMER
LOCATION & EXTERIOR ELECTRICAL GEAR.
11.SEE MECH/PLUMB SHEETS FOR LOCATIONS OF MECH/PLUMB
EQUIPMENT.
12.PROVIDE A HVAC SERVICE RECEPTACLE, SEE MECH SHEETS FOR
EXTERIOR AC LOCATIONS.
13.ABIDE ALL LOCAL ORDINANCES & CODES
A SERVICE LIGHT & SWITCH WILL
BE REQUIRED, TO BE PROVIDED BY
EC. FOLLOW MANUFACTURER
INSTALLATION INSTRUCTIONS.
ERV
1
ERV
1
ERV
1
PB-40,42
PB-44,46
PB-43,45
S2
S2 S2
GENERAL CONTRACTOR
Janckila Construction Inc.
75 Buckskin Drive
Carbondale, CO 81623
T 970.963.7239
F 970.963.7239
STRUCTURAL ENGINEER
Albright and Associates
402 Park Ave., Unit A
Basalt, CO 81621
T 970.927.4363
CIVIL ENGINEER
Roaring Fork Engineering
592 Highway 133,
Carbondale, CO 81623
T 970.948.7474
MEP ENGINEER
Bighorn Consulting Enginners, Inc.
386 Indian Road
Grand Junction, CO 81501
T 970.241.8709
ACOUSTIC CONSULTANT
Acentech
33 Moulton Street
Cambridge, MA 02138
T 617.499.8000
F 617.499.8074
61
7
W
E
S
T
B
L
E
E
K
E
R
S
T
R
E
E
T
AS
P
E
N
AS
P
E
N
,
C
O
8
1
6
1
1
Drawing Title:
Drawing No:
Phase:
Architect
29 Stanhope Street
3rd Floor
Boston, MA 02116
T 617.426.0995
F 617.426.0998
MONICA PONCE DE LEON
STUDIO, INC.
DATE & ISSUE DESCRIPTION BY CHECK
ISSUE/
REVISION
Project Number:
19-046
RE
S
I
D
E
N
C
E
09/19/2019 PERMIT SET BHCE BHCE1
E2-1
BASEMENT LEVEL FLOOR PLAN
1 ELECTRICAL - BASEMENT LEVEL FLOOR PLAN
SCALE: 1/4" = 1'-0"
ELECTRICAL
N
2019-09-19
11/20/2019
01/28/2020
tonyf
EP
2015 IRC Code References
EP electric panel happy space 30in x 36in x 78in, not in storage, 2014 NEC 110.26
PACKAGE ROOM
105
GARAGE
110
MUDROOM
111
LAUNDRY ROOM
109
CORRIDOR
107
ENTRY CLOSET
106
POWDER ROOM
108
MASTER BATHROOM
104
FC
4
H
4 FC
1
H
1
EF
1
EF
1
EF
1
EF
2
EF
1
EF
1
EF
1
EF
1
EF
1
S S
S S
GFCI
WP
GFCI
44"
GFCI
44"
GFCI
44"
WASHER
DRYER
GFCI
44"
GFCI
WP
PG - PANEL
GROUND
GFCI
GFCI
GFCI GFCI
GFCI
GFCI
GFCI
GFCI
GFCI
PG-1
PG-2
PG-3
PG-4
PG-6
PG-5
GFCI
PG-8,10
PG-7
PG-9
S
PG-11
PG-42 PG-41PG-39 PG-40
GARAGE
DOOR
OPENER
GARAGE
DOOR
OPENER
PG-12
PG-13
IN CEILING
ERV
1 ERV
1
PG-35,37 PG-36,38
S2S2
MDP
UTILITY
METER
UTILITY CT
CABINET
SERVICE RATED
TRANSFER
SWITCH
GENERATOR
E2-2
GENERAL CONTRACTOR
Janckila Construction Inc.
75 Buckskin Drive
Carbondale, CO 81623
T 970.963.7239
F 970.963.7239
STRUCTURAL ENGINEER
Albright and Associates
402 Park Ave., Unit A
Basalt, CO 81621
T 970.927.4363
CIVIL ENGINEER
Roaring Fork Engineering
592 Highway 133,
Carbondale, CO 81623
T 970.948.7474
MEP ENGINEER
Bighorn Consulting Enginners, Inc.
386 Indian Road
Grand Junction, CO 81501
T 970.241.8709
ACOUSTIC CONSULTANT
Acentech
33 Moulton Street
Cambridge, MA 02138
T 617.499.8000
F 617.499.8074
61
7
W
E
S
T
B
L
E
E
K
E
R
S
T
R
E
E
T
AS
P
E
N
AS
P
E
N
,
C
O
8
1
6
1
1
Drawing Title:
Drawing No:
Phase:
Architect
29 Stanhope Street
3rd Floor
Boston, MA 02116
T 617.426.0995
F 617.426.0998
MONICA PONCE DE LEON
STUDIO, INC.
DATE & ISSUE DESCRIPTION BY CHECK
ISSUE/
REVISION
Project Number:
19-046
RE
S
I
D
E
N
C
E
09/19/2019 PERMIT SET BHCE BHCE1
GROUND LEVEL FLOOR PLAN
1 ELECTRICAL - GROUND LEVEL FLOOR PLAN
SCALE: 1/4" = 1'-0"
ELECTRICAL
N
2019-09-19
11/20/2019
01/28/2020
tonyf
2015 IRC Code References
EP electric panel happy space 30in x 36in x 78in, not in storage, 2014 NEC 110.26
EP
BEDROOM 1
106
BEDROOM 2
108
BEDROOM 3
110
BATHROOM 1
107
BATHROOM 3
111
BATHROOM 2
109
FC
6
H
6
EF
1
EF
1
EF
1
EF
1
FC
6
H
6
EF
1
EF
1
EF
1
EF
1
SS
GFCI
44"
GFCI
44"
GFCI
44"
GFCI
44"
PA-2
PA-3
PA-4
PA-5
PA-5
PA-8, PARTIAL
PA-8, PARTIAL PA-8, PARTIAL
PA-8, PARTIAL
PA-7
PA-9
PA-10
PA-12,14
J
FIREPLACE
PA-11
PA-13
PA-42PA-41
MDP-18,20
HOT TUB
240V 50A GFCI C.B.
COORDINATE WITH
OTHERS FOR
KITCHEN LAYOUT
GENERAL CONTRACTOR
Janckila Construction Inc.
75 Buckskin Drive
Carbondale, CO 81623
T 970.963.7239
F 970.963.7239
STRUCTURAL ENGINEER
Albright and Associates
402 Park Ave., Unit A
Basalt, CO 81621
T 970.927.4363
CIVIL ENGINEER
Roaring Fork Engineering
592 Highway 133,
Carbondale, CO 81623
T 970.948.7474
MEP ENGINEER
Bighorn Consulting Enginners, Inc.
386 Indian Road
Grand Junction, CO 81501
T 970.241.8709
ACOUSTIC CONSULTANT
Acentech
33 Moulton Street
Cambridge, MA 02138
T 617.499.8000
F 617.499.8074
61
7
W
E
S
T
B
L
E
E
K
E
R
S
T
R
E
E
T
AS
P
E
N
AS
P
E
N
,
C
O
8
1
6
1
1
Drawing Title:
Drawing No:
Phase:
Architect
29 Stanhope Street
3rd Floor
Boston, MA 02116
T 617.426.0995
F 617.426.0998
MONICA PONCE DE LEON
STUDIO, INC.
DATE & ISSUE DESCRIPTION BY CHECK
ISSUE/
REVISION
Project Number:
19-046
RE
S
I
D
E
N
C
E
09/19/2019 PERMIT SET BHCE BHCE1
1 ELECTRICAL - SECOND LEVEL FLOOR PLAN
SCALE: 1/4" = 1'-0"
E2-3
ELECTRICAL
SECOND LEVEL FLOOR PLAN
N
2019-09-19
11/20/2019
01/28/2020
tonyf
ATTIC
301
PA - PANEL
ATTIC
PA-1
GENERAL CONTRACTOR
Janckila Construction Inc.
75 Buckskin Drive
Carbondale, CO 81623
T 970.963.7239
F 970.963.7239
STRUCTURAL ENGINEER
Albright and Associates
402 Park Ave., Unit A
Basalt, CO 81621
T 970.927.4363
CIVIL ENGINEER
Roaring Fork Engineering
592 Highway 133,
Carbondale, CO 81623
T 970.948.7474
MEP ENGINEER
Bighorn Consulting Enginners, Inc.
386 Indian Road
Grand Junction, CO 81501
T 970.241.8709
ACOUSTIC CONSULTANT
Acentech
33 Moulton Street
Cambridge, MA 02138
T 617.499.8000
F 617.499.8074
61
7
W
E
S
T
B
L
E
E
K
E
R
S
T
R
E
E
T
AS
P
E
N
AS
P
E
N
,
C
O
8
1
6
1
1
Drawing Title:
Drawing No:
Phase:
Architect
29 Stanhope Street
3rd Floor
Boston, MA 02116
T 617.426.0995
F 617.426.0998
MONICA PONCE DE LEON
STUDIO, INC.
DATE & ISSUE DESCRIPTION BY CHECK
ISSUE/
REVISION
Project Number:
19-046
RE
S
I
D
E
N
C
E
09/19/2019 PERMIT SET BHCE BHCE1
ATTIC LEVEL FLOOR PLAN
1 ELECTRICAL - ATTIC LEVEL FLOOR PLAN
SCALE: 1/4" = 1'-0"
E2-4
ELECTRICAL
N
2019-09-19
11/20/2019
01/28/2020
tonyf
EP
2015 IRC Code References
EP electric panel happy space 30in x 36in x 78in, not in storage, 2014 NEC 110.26
ASSUMED 150KVA
UTILITY TRANSFORMER
CABINET
CT
NEMA 3R
MDP: 240V, 600AMP BUSSED
ONE-LINE DIAGRAM
NOT TO SCALE
44,400 SCA
400A C.B.
SCHEMATIC FOR A GROUNDING ELECTRODE SYSTEM
NOT SCALE
METALLIC MAIN DOMESTIC
COLD WATER PIPE
(MIN 10')
CONCRETE ENCASED ELECTRODE
(MIN. 20'LF OF CONDUCTOR)
REBAR TO BE ENCASED BY A
MINIMUM OF 2" OF CONCRETE
CONNECTION MADE
WITHIN 5' OF POINT OF
ENTRANCE OF PIPE
2/0 CU
STRUCTURAL
STEEL FRAME
OF BUILDING
FOUNDATION
FOOTER
GROUND ROD
(10'L x 3/4"DIA)
COPPER CLAD
MIN.
#6 CU
MIN.
#4 CU
2/0 CU
NOTES:
1. PROVIDE INFORMATION REQUIRED BY NEC 110.24 TO THE SERVICE EQUIPMENT.
2. PROVIDE INFORMATION ON ALL ELECTRICAL PANELBOARDS AND SWITCHBOARDS REQUIRED BY NEC 110.16
3. PROVIDE GROUNDING AT THE MDP PER NEC REQUIREMENTS
4. ALL WIRE SIZES ARE CU UNLESS SPECIFIED
PB
400A MLO
1ɸ
120/240
NEMA 1
200A C.B.
PG
225A MLO
1ɸ
120/240
NEMA 1
200A C.B.
PA
225A MLO
1ɸ
120/240
NEMA 1
WIRE SIZES:
2(3.5"C-3#350KCMIL)
2.5"C-3#3/0 + #6 GND
1''C-3#8 + #10 GND
3/4''C-3#10 + #10 GND
2(3.5"C-3#350KCMIL + #1 GND)
2(2.5"C-3#3/0 + #3 GND)
1
2
3
1
1
6 2 2
CU-1 CU-2
50A C.B.50A C.B.
F F
50A C.B.
HOT TUB
3
GFCI
50A C.B.
3 3
4
240V
50A FUSE
CU-3 CU-4
50A C.B.50A C.B.
F F
33
CU-5 CU-6
30A C.B.50A C.B.
F F
34
240V
30A FUSE
240V
50A FUSE
240V
50A FUSE
240V
50A FUSE
240V
50A FUSE
31,560 SCA
26,546 SCA 19,218 SCA 17,977 SCA
3,021 SCA
5. USE FLNR OR SIMILAR CURRENT LIMITING FUSES
120/240V NATURAL GAS GENERATOR
LOCATED IN ASPEN, COLORADO
POWERS THE WHOLE HOUSE
CAPABLE OF 600A
600AMP C.B.
5
SERVICE RATED TRANSFER SWITCH
120/240V 1Ø 600A
3 WIRE TRANSFER SWITCH
NEMA 3R
600AMP MAIN C.B.
5
5
31,560 SCA
PANEL SCHEDULE - MDP TYPE:DISTRIBUTION PANEL BUS SIZE:600 PHASES:1 NEUTRAL BUS:YES
VOLTAGE:120/240 MAIN BRKR:NONE WIRES:3 GROUND BUS:YES
ENCLOSURE:NEMA3R MOUNTING:SURFACE SC RATING:42000
LOAD TYPE LOAD DESCRIPTION AMPS CKT#0/CKT#AMPS LOAD TYPE LOAD DESCRIPTION
POLES LOAD LOAD POLES
SUBFEED PANEL PB 400A 1 A 2 225A SUBFEED PANEL PG
---2P 27682 16412 2P ---
SUBFEED ------3 B 4 ---SUBFEED ---
------27790 12496 ------
SUBFEED PANEL PA 225A 5 A 6 50A MECH COOLING CU-1
---2P 18400 3492 2P ---
SUBFEED ------7 B 8 ---MECH COOLING ---
------15420 3492 ------
MECH COOLING CU-2 50A 9 A 10 50A MECH COOLING CU-3
---2P 3492 3492 2P ---
MECH COOLING ------11 B 12 ---MECH COOLING ---
------3492 3492 ------
MECH COOLING CU-4 50A 13 A 14 30A MECH COOLING CU-5
---2P 3492 2292 2P ---
MECH COOLING ------15 B 16 ---MECH COOLING ---
------3492 2292 ------
MECH COOLING CU-6 50A 17 A 18 50A MISCELLANEOUS HOT TUB
---2P 3492 4800 2P ---
MECH COOLING ------19 B 20 ---MISCELLANEOUS ---
------3492 4800 ------
SPACE ------21 A 22 ---SPACE ---
------0 0 ------
SPACE ------23 B 24 ---SPACE ---
------0 0 ------
SPACE ------25 A 26 ---SPACE ---
------0 0 ------
SPACE ------27 B 28 ---SPACE ---
------0 0 ------
SPACE ------29 A 30 ---SPACE ---
------0 0 ------
SPACE ------31 B 32 ---SPACE ---
------0 0 ------
SPACE ------33 A 34 ---SPACE ---
------0 0 ------
SPACE ------35 B 36 ---SPACE ---
------0 0 ------
SPACE ------37 A 38 ---SPACE ---
------0 0 ------
SPACE ------39 B 40 ---SPACE ---
------0 0 ------
SPACE ------41 A 42 ---SPACE ---
------0 0 ------
LOADS BY TYPE:LOADS BY PHASE:
LOAD CONNECTED DEMAND DEMAND CONNECTED CONNECTED BALANCE
TYPE LOAD (VA)FACTOR LOAD (VA)PHASE LOAD (VA)LOAD (AMPS)(PERCENT)
LIGHTING 12000.00 1.25 15000.00 A 87046.00 725.38 A-B: 92.2
KITCHEN 0.00 1.00 0.00 B 80258.00 668.82 B-A: 92.2
PROCESS 0.00 1.00 0.00 C ---------
RECEPTACLES 10000.00 1.00 10000.00
RECEPTACLES 9580.00 0.50 4790.00 TOTAL/AVERAGE 167304.00 697.10 92.2
MECH HEATING 0.00 1.00 0.00
MECH COOLING 39504.00 1.00 39504.00
MECH YEAR ROUND 20064.00 1.00 20064.00 NOTES:
APPLIANCE 16500.00 1.00 16500.00
MISCELLANEOUS 19500.00 1.00 19500.00 1. THE LARGEST CONNECTED MOTOR LOAD IS INCLUDED IN MECHANICAL, PROCESS, OR MOTOR LOADS.
MOTOR 11248.00 1.00 16872.00
SPARE 0.00 1.00 0.00
LARGEST MOTOR 1 ABOVE 0.25 1746.00
TOTAL 167304.00 138352.00
6
PANEL SCHEDULE - PB TYPE:PANELBOARD BUS SIZE:400 PHASES:1 NEUTRAL BUS:YES
VOLTAGE:120/240 MAIN BRKR:400 WIRES:3 GROUND BUS:YES
ENCLOSURE:NEMA1 MOUNTING:SURFACE SC RATING:42000
LOAD TYPE LOAD DESCRIPTION AMPS CKT#0/CKT#AMPS LOAD TYPE LOAD DESCRIPTION
POLES LOAD LOAD POLES
RECEPTACLE MEDIA RM 20A 1 A 2 20A RECEPTACLE MEDIA CENTER
---1P 1080 360 1P ---
RECEPTACLE BASEMENT BATHROOMS 20A 3 B 4 20A MOTOR WASHING MACHINE
---1P 360 1200 1P ---
RECEPTACLE LAUNDRY RM 20A 5 A 6 30A RECEPTACLE DRYER
---1P 360 2500 2P ---
MOTOR SUMP PUMP 20A 7 B 8 ---RECEPTACLE ---
---1P 1000 2500 ------
MISCELLANEOUS ELEVATOR CNTRL 20A 9 A 10 20A MISCELLANEOUS ELEVATOR CAB
---1P 500 500 1P ---
RECEPTACLE ELEVATOR PIT 20A 11 B 12 20A MOTOR ELEVATOR
---1P 180 1440 2P ---
RECEPTACLE STORAGE & MECH 20A 13 A 14 ---MOTOR ---
---1P 720 1440 ------
MOTOR GUEST WASHING MACH 20A 15 B 16 30A APPLIANCE GUEST DRYER
---1P 1200 2500 2P ---
APPLIANCE GUEST REFRIGERATOR 20A 17 A 18 ---APPLIANCE ---
---1P 700 2500 ------
RECEPTACLE GUEST BDRM 20A 19 B 20 20A RECEPTACLE WORKOUT RM
---1P 1080 540 1P ---
RECEPTACLE SPORT COURT 20A 21 A 22 20A MISCELLANEOUS GYM EQP
---1P 1080 1200 1P ---
MISCELLANEOUS SAUNA 20A 23 B 24 20A MISCELLANEOUS GYM EQP
---1P 1700 1200 1P ---
SPACE ------25 A 26 ---SPACE ---
------0 0 ------
SPACE ------27 B 28 ---SPACE ---
------0 0 ------
SPACE ------29 A 30 ---SPACE ---
------0 0 ------
SPACE ------31 B 32 ---SPACE ---
------0 0 ------
SPACE ------33 A 34 ---SPACE ---
------0 0 ------
SPACE ------35 B 36 20A LIGHTING LIGHTING
------0 1200 1P ---
LIGHTING LIGHTING 20A 37 A 38 20A LIGHTING LIGHTING
---1P 1200 1200 1P ---
LIGHTING LIGHTING 20A 39 B 40 20A MOTOR ERV-1
---1P 1200 828 2P ---
LIGHTING LIGHTING 20A 41 A 42 ---MOTOR ---
---1P 1200 828 ------
MOTOR ERV-1 20A 43 B 44 20A MOTOR ERV-1
---2P 828 828 2P ---
MOTOR ------45 A 46 ---MOTOR ---
------828 828 ------
MECH YEAR ROUND BOILER 1 20A 47 B 48 20A MECH YEAR ROUND BOILER 1
---1P 2 2 1P ---
MECH YEAR ROUND FC-2 20A 49 A 50 20A MECH YEAR ROUND H-2
---1P 1200 1900 1P ---
MECH YEAR ROUND H-3 20A 51 B 52 20A MECH YEAR ROUND FC-3
---1P 1900 1200 1P ---
MECH YEAR ROUND FC-5 20A 53 A 54 20A MECH YEAR ROUND H-5
---1P 1200 1900 1P ---
MECH YEAR ROUND RCP-1 20A 55 B 56 20A MECH YEAR ROUND CP-2
---2P 280 1100 1P ---
MECH YEAR ROUND ------57 A 58 20A MECH YEAR ROUND CP-4
------280 500 1P ---
MECH YEAR ROUND CP-3 20A 59 B 60 20A MECH YEAR ROUND CP-5
---1P 1550 1100 1P ---
MECH YEAR ROUND CP-6 20A 61 A 62 20A MECH YEAR ROUND CP-7
---1P 1550 500 1P ---
MECH YEAR ROUND CP-8 20A 63 B 64 ---SPACE ---
---1P 500 0 ------
LOADS BY TYPE:LOADS BY PHASE:
LOAD CONNECTED DEMAND DEMAND CONNECTED CONNECTED BALANCE
TYPE LOAD (VA)FACTOR LOAD (VA)PHASE LOAD (VA)LOAD (AMPS)(PERCENT)
LIGHTING 6000.00 1.25 7500.00 A 28054.00 233.78 A-B: 97.7
KITCHEN 0.00 0.00 0.00 B 27418.00 228.48 B-A: 97.7
PROCESS 0.00 1.00 0.00 C ---------
RECEPTACLES 10000.00 1.00 10000.00
RECEPTACLES 760.00 0.50 380.00 TOTAL/AVERAGE 55472.00 231.13 97.7
MECH HEATING 0.00 1.00 0.00
MECH COOLING 0.00 1.00 0.00
MECH YEAR ROUND 16664.00 1.00 16664.00 NOTES:
APPLIANCE 5700.00 1.00 5700.00
MISCELLANEOUS 5100.00 1.00 5100.00 1. THE LARGEST CONNECTED MOTOR LOAD IS INCLUDED IN MECHANICAL, PROCESS, OR MOTOR LOADS.
MOTOR 11248.00 1.00 16872.00
SPARE 0.00 1.00 0.00
LARGEST MOTOR 1 ABOVE 0.25 720.00
TOTAL 55472.00 57312.00
GENERAL CONTRACTOR
Janckila Construction Inc.
75 Buckskin Drive
Carbondale, CO 81623
T 970.963.7239
F 970.963.7239
STRUCTURAL ENGINEER
Albright and Associates
402 Park Ave., Unit A
Basalt, CO 81621
T 970.927.4363
CIVIL ENGINEER
Roaring Fork Engineering
592 Highway 133,
Carbondale, CO 81623
T 970.948.7474
MEP ENGINEER
Bighorn Consulting Enginners, Inc.
386 Indian Road
Grand Junction, CO 81501
T 970.241.8709
ACOUSTIC CONSULTANT
Acentech
33 Moulton Street
Cambridge, MA 02138
T 617.499.8000
F 617.499.8074
61
7
W
E
S
T
B
L
E
E
K
E
R
S
T
R
E
E
T
AS
P
E
N
AS
P
E
N
,
C
O
8
1
6
1
1
Drawing Title:
Drawing No:
Phase:
Architect
29 Stanhope Street
3rd Floor
Boston, MA 02116
T 617.426.0995
F 617.426.0998
MONICA PONCE DE LEON
STUDIO, INC.
DATE & ISSUE DESCRIPTION BY CHECK
ISSUE/
REVISION
Project Number:
19-046
RE
S
I
D
E
N
C
E
09/19/2019 PERMIT SET BHCE BHCE1
ONELINE & SCHEDULES
E2-5
ELECTRICAL
2019-09-19
11/20/2019
01/28/2020
tonyf
WALL MOUNTED
EMERGENCY LIGHT
48"
90"
44"48"
80"
60"
MOUNTING HEIGHT DETAIL
NOT TO SCALE
CABINETS
OFFOFF
ONON
RECEPTACLE
FINISHED FLOOR
DUPLEX 16"
TELEPHONE
COMBINATION COAX,
COMPUTER
DUPLEX
RECEPTACLE
TELEVISION
PULL STATION
DOOR WAY
EXIT
HORN STROBE
FIRE ALARM
FIRE ALARM
WALL
72"
COAX
THERMOSTAT
WITH IN 18"
NOTES:
1.THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF ALL TELEVISION OUTLETS WITH THE
ARCHITECT PRIOR TO INSTALLATION.
2.ALL DEVICES SHOWN ON THIS DETAIL ARE FOR REFERENCES OF MOUNTING HEIGHTS ONLY. THE ELECTRICAL
CONTRACTOR SHALL FIELD ADJUST THE HEIGHTS OF THE DEVICES AS REQUIRED FOR PROPER MOUNTING OF
THE DEVICES.
3.ALL DEVICES REQUIRED FOR THIS PROJECT MAY NOT APPEAR ON THIS DETAIL. ALL ITEMS SHOWN ON THIS
DETAIL MAY NOT BE REQUIRED FOR THIS PROJECT.
FUSE
DISCSTART
SIZE
BRKRBRANCH CIRCUIT
AMPS
LOAD
FULLUNIT
NO
LOADFUNCTION
(NOTES)
VOLTS Ø
CONDUIT
CONDUCTOR SIZE
MECHANICAL EQUIPMENT SCHEDULE
COMB: COMBINATION MOTOR STARTER
MAG: MAGNETIC MOTOR STARTER
NR: NONE REQUIRED
P/I: PLUG-IN UNIT
CONT: CONTRACTOR
MAN: MANUAL MOTOR STARTER
W/U: SUPPLIED WITH UNIT:
SIZE
NO.WIRE
GRND
WIRE
SIZE
CU-1 CONDENSING UNIT (1,2,3,4,6 SIMILAR)6984 240 1 29.1 1''2 8 10 50 60
50
CU-5 CONDENSING UNIT 5 4584 240 1 19.1 3/4''2 10 10 30 30
30
RCP-1 DOMESTIC WATER RECIRC 560 240 1 2 3/4''2 12 12 20
CP-2 BOILER PUMP: CP-5 SIMILAR 1100 120 1 9.2 3/4''2 12 12 20
ELECTRICAL LEGEND
BRANCH CIRCUIT PANELBOARD
TELEPHONE TERMINAL BOARD
MOTOR
FUSED SAFETY SWITCH / DISCONNECT
COMBINATION MOTOR STARTER
CONTACTOR
CIRCUITRY HOMERUN: PANEL LA - CIR. #7
CONDUIT OR WIRE CONCEALED IN WALL/CLG.
CONDUIT OR WIRE UNDERFLOOR/UNDERGND.
CEILING JUNCTION BOX - SURFACE/FLUSH
WALL JUNCTION BOX - SURFACE/FLUSH
DUPLEX RECEPTACLE
SPLIT WIRED DUPLEX RECEPTACLE
FOURPLEX RECEPTACLE
APPLIANCE RECEPTACLE - 3 WIRE
THERMOSTAT
TELEPHONE OUTLET
COMPUTER-DATA
COMBINATION DATA/TELEPHONE
TELEVISION OUTLET
SINGLE POLE SWITCH
TWO POLE SWITCH
THREE-WAY SWITCH
FOUR-WAY SWITCH
DIMMER SWITCH
MANUAL MOTOR STARTER
FLUORESCENT FIXTURE TYPE A
WALL BRACKET FLUORESCENT FIXTURE
OPEN STRIP FLUORESCENT FIXTURE
SURFACE CEILING INCANDESCENT OR H.I.D. FIXTURE
WALL MOUNTED INCANDESCENT OR H.I.D. FIXTURE
RECESSED CEILING DOWN LIGHT
DOUBLE FACE EXIT SIGN, WALL AND CEILING MOUNTED
SINGLE FACE EXIT SIGN, WALL AND CEILING MOUNTED
WALL MOUNTED EMERGENCY LIGHT
REMOTE MOUNTED EMERGENCY HEAD
MECHANICAL CONTRACTOR FURNISHED EQUIPMENT
OWNER FURNISHED EQUIPMENT
DRAWING FLAG NOTE
ROOM DESIGNATION
EXISTING NIGHT/SECURITY LIGHT - DO NOT SWITCH
WEATHERPROOF
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
GROUND FAULT CIRCUIT INTERRUPTER
RECEPTACLE IS GFCI PROTECTED FROM AN UP STREAM
GFCI RECEPTACLE
EMERGENCY FUNCTION
MOUNTING HEIGHT - A.F.F. OR A.F.G. TO C.L. HIGH INTENSITY
DISCHARGE LIGHTING TYPE CIRCUIT BREAKER U.L. LISTED AS
SWITCHING DUTY CIRCUIT BREAKER
S
S
S
S
S
S
S2
S
CP-3 SNOWMELT PUMP: CP-6 SIMILAR 1550 120 1 13 3/4''2 12 12 20 S
CP-4 RADIANT CIRCULATION: CP-7,8 SMLR 500 120 1 4.2 3/4''2 12 12 20 S
PANEL SCHEDULE - PG TYPE:PANELBOARD BUS SIZE:225 PHASES:1 NEUTRAL BUS:YES
VOLTAGE:120/240 MAIN BRKR:225 WIRES:3 GROUND BUS:YES
ENCLOSURE:NEMA1 MOUNTING:SURFACE SC RATING:22000
LOAD TYPE LOAD DESCRIPTION AMPS CKT#0/CKT#AMPS LOAD TYPE LOAD DESCRIPTION
POLES LOAD LOAD POLES
RECEPTACLE CORRIDOR, PACK RM, OUTSIDE 20A 1 A 2 20A RECEPTACLE BATHROOMS
---1P 900 720 1P ---
RECEPTACLE MUDROOM 20A 3 B 4 20A RECEPTACLE MASTER BDRM
---1P 1080 1620 1P ---
RECEPTACLE WASHING MACHINE 20A 5 A 6 20A RECEPTACLE LAUNDRY RM
---1P 1200 360 1P ---
RECEPTACLE GARAGE 20A 7 B 8 30A APPLIANCE DRYER
---1P 540 2500 2P ---
RECEPTACLE GARAGE 20A 9 A 10 ---APPLIANCE ---
---1P 720 2500 ------
MISCELLANEOUS EF-2 20A 11 B 12 20A MOTOR GARAGE DOOR OPENER
---1P 56 1200 1P ---
MOTOR GARAGE DOOR OPENER 20A 13 A 14 ---SPACE ---
---1P 1200 0 ------
SPACE ------15 B 16 ---SPACE ---
------0 0 ------
SPACE ------17 A 18 ---SPACE ---
------0 0 ------
SPACE ------19 B 20 ---SPACE ---
------0 0 ------
SPACE ------21 A 22 ---SPACE ---
------0 0 ------
SPACE ------23 B 24 ---SPACE ---
------0 0 ------
SPACE ------25 A 26 ---SPACE ---
------0 0 ------
SPACE ------27 B 28 ---SPACE ---
------0 0 ------
SPACE ------29 A 30 ---SPACE ---
------0 0 ------
LIGHTING LIGHTING 20A 31 B 32 20A LIGHTING LIGHTING
---1P 1200 1200 1P ---
LIGHTING LIGHTING 20A 33 A 34 20A LIGHTING LIGHTING
---1P 1200 1200 1P ---
MOTOR ERV-1 20A 35 B 36 20A MOTOR ERV-1
---2P 828 828 2P ---
MOTOR ------37 A 38 ---MOTOR ---
------828 828 ------
MECH YEAR ROUND H-4 20A 39 B 40 20A MECH YEAR ROUND FC-4
---1P 1900 1200 1P ---
MECH YEAR ROUND FC-1 20A 41 A 42 20A MECH YEAR ROUND H-1
---1P 1200 1900 1P ---
LOADS BY TYPE:LOADS BY PHASE:
LOAD CONNECTED DEMAND DEMAND CONNECTED CONNECTED BALANCE
TYPE LOAD (VA)FACTOR LOAD (VA)PHASE LOAD (VA)LOAD (AMPS)(PERCENT)
LIGHTING 4800.00 1.25 6000.00 A 14756.00 122.97 A-B: 95.9
KITCHEN 0.00 0.00 0.00 B 14152.00 117.93 B-A: 95.9
PROCESS 0.00 1.00 0.00 C ---------
RECEPTACLES 7140.00 1.00 7140.00
MECH HEATING 0.00 1.00 0.00 TOTAL/AVERAGE 28908.00 120.45 95.9
MECH COOLING 0.00 1.00 0.00
MECH YEAR ROUND 6200.00 1.00 6200.00 NOTES:
APPLIANCE 5000.00 1.00 5000.00
MISCELLANEOUS 56.00 1.00 56.00 1. THE LARGEST CONNECTED MOTOR LOAD IS INCLUDED IN MECHANICAL, PROCESS, OR MOTOR LOADS.
MOTOR 5712.00 1.00 8568.00
SPARE 0.00 1.00 0.00
LARGEST MOTOR 1 ABOVE 0.25 475.00
TOTAL 28908.00 30583.00
PANEL SCHEDULE - PA TYPE:PANELBOARD BUS SIZE:225 PHASES:1 NEUTRAL BUS:YES
VOLTAGE:120/240 MAIN BRKR:225 WIRES:3 GROUND BUS:YES
ENCLOSURE:NEMA1 MOUNTING:SURFACE SC RATING:22000
LOAD TYPE LOAD DESCRIPTION AMPS CKT#0/CKT#AMPS LOAD TYPE LOAD DESCRIPTION
POLES LOAD LOAD POLES
RECEPTACLE ATTIC 20A 1 A 2 20A RECEPTACLE KITCHEN
---1P 540 360 1P ---
RECEPTACLE KITCHEN 20A 3 B 4 20A RECEPTACLE KITCHEN
---1P 360 360 1P ---
RECEPTACLE DINNING RM 20A 5 A 6 20A RECEPTACLE KITCHEN
---1P 900 360 1P ---
RECEPTACLE BDRM 1 20A 7 B 8 20A RECEPTACLE 2ND FLR BTHRMS
---1P 1260 720 1P ---
RECEPTACLE BDRM 2 20A 9 A 10 20A RECEPTACLE BDRM 3
---1P 1260 1260 1P ---
RECEPTACLE LIVING RM 20A 11 B 12 50A APPLIANCE STOVE
---1P 720 4800 2P ---
RECEPTACLE LIVING RM 20A 13 A 14 ---APPLIANCE ---
---1P 720 4800 ------
SPACE ------15 B 16 20A APPLIANCE DISHWASHER
------0 1200 1P ---
SPACE ------17 A 18 ---SPACE ---
------0 0 ------
SPACE ------19 B 20 ---SPACE ---
------0 0 ------
SPACE ------21 A 22 ---SPACE ---
------0 0 ------
SPACE ------23 B 24 ---SPACE ---
------0 0 ------
SPACE ------25 A 26 ---SPACE ---
------0 0 ------
SPACE ------27 B 28 ---SPACE ---
------0 0 ------
SPACE ------29 A 30 ---SPACE ---
------0 0 ------
LIGHTING LIGHTING 20A 31 B 32 ---SPACE ---
---1P 1200 0 ------
LIGHTING LIGHTING 20A 33 A 34 20A LIGHTING LIGHTING
---1P 1200 1200 1P ---
LIGHTING LIGHTING 20A 35 B 36 20A LIGHTING LIGHTING
---1P 1200 1200 1P ---
MISCELLANEOUS GUTTER SNOW MELT 30A 37 A 38 ---SPACE ---
---2P 2400 0 ------
MISCELLANEOUS ------39 B 40 ---SPACE ---
------2400 0 ------
MECH YEAR ROUND FC-6 20A 41 A 42 20A MECH YEAR ROUND H-6
---1P 1500 1900 1P ---
LOADS BY TYPE:LOADS BY PHASE:
LOAD CONNECTED DEMAND DEMAND CONNECTED CONNECTED BALANCE
TYPE LOAD (VA)FACTOR LOAD (VA)PHASE LOAD (VA)LOAD (AMPS)(PERCENT)
LIGHTING 6000.00 1.25 7500.00 A 18400.00 153.33 A-B: 83.8
KITCHEN 0.00 0.00 0.00 B 15420.00 128.50 B-A: 83.8
PROCESS 0.00 1.00 0.00 C ---------
RECEPTACLES 8820.00 1.00 8820.00
MECH HEATING 0.00 1.00 0.00 TOTAL/AVERAGE 33820.00 140.92 83.8
MECH COOLING 0.00 1.00 0.00
MECH YEAR ROUND 3400.00 1.00 3400.00 NOTES:
APPLIANCE 10800.00 1.00 10800.00
MISCELLANEOUS 4800.00 1.00 4800.00 1. THE LARGEST CONNECTED MOTOR LOAD IS INCLUDED IN MECHANICAL, PROCESS, OR MOTOR LOADS.
MOTOR 0.00 1.00 0.00
SPARE 0.00 1.00 0.00
LARGEST MOTOR 1 ABOVE 0.25 475.00
TOTAL 33820.00 35795.00
GENERAL CONTRACTOR
Janckila Construction Inc.
75 Buckskin Drive
Carbondale, CO 81623
T 970.963.7239
F 970.963.7239
STRUCTURAL ENGINEER
Albright and Associates
402 Park Ave., Unit A
Basalt, CO 81621
T 970.927.4363
CIVIL ENGINEER
Roaring Fork Engineering
592 Highway 133,
Carbondale, CO 81623
T 970.948.7474
MEP ENGINEER
Bighorn Consulting Enginners, Inc.
386 Indian Road
Grand Junction, CO 81501
T 970.241.8709
ACOUSTIC CONSULTANT
Acentech
33 Moulton Street
Cambridge, MA 02138
T 617.499.8000
F 617.499.8074
61
7
W
E
S
T
B
L
E
E
K
E
R
S
T
R
E
E
T
AS
P
E
N
AS
P
E
N
,
C
O
8
1
6
1
1
Drawing Title:
Drawing No:
Phase:
Architect
29 Stanhope Street
3rd Floor
Boston, MA 02116
T 617.426.0995
F 617.426.0998
MONICA PONCE DE LEON
STUDIO, INC.
DATE & ISSUE DESCRIPTION BY CHECK
ISSUE/
REVISION
Project Number:
19-046
RE
S
I
D
E
N
C
E
09/19/2019 PERMIT SET BHCE BHCE1
SCHEDULES & DETAILS
E2-6
ELECTRICAL
2019-09-19
11/20/2019
01/28/2020
tonyf
SECTION 16000
GENERAL PROVISIONS
SECTION 16010
GENERAL PROVISIONS
A.THE ARCHITECTURAL GENERAL AND SPECIAL CONDITIONS FOR THE CONSTRUCTION OF THIS
PROJECT SHALL BE A PART OF THE ELECTRICAL SPECIFICATIONS. THE ELECTRICAL
CONTRACTOR SHALL EXAMINE THE GENERAL AND SPECIAL CONDITIONS BEFORE SUBMITTING
HIS OR HER PROPOSAL.
B.THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK INCLUDED IN THIS
SECTION AND THE DELEGATION OF WORK TO THE ELECTRICAL CONTRACTOR, SHALL NOT
RELIEVE HIM OF THIS RESPONSIBILITY. THE ELECTRICAL CONTRACTOR AND HIS
SUBCONTRACTORS WHO PERFORM WORK UNDER THIS SECTION SHALL BE RESPONSIBLE TO
THE GENERAL CONTRACTOR.
C.WHERE ITEMS OF THE GENERAL CONDITIONS OR OF THE SPECIAL CONDITIONS ARE REPEATED
IN THIS SECTION OF THE SPECIFICATIONS, IT IS INTENDED TO RE-ENFORCE OR QUALIFY THEM; IT
IS NOT INTENDED THAT ANY OTHER PARTS OF THE GENERAL CONDITIONS OR SPECIAL
CONDITIONS SHALL BE ASSUMED TO BE OMITTED IF NOT REPEATED HEREIN.
D.THE NAMING OF A CERTAIN BRAND OR MAKE OR MANUFACTURER IN THE SPECIFICATIONS IS TO
ESTABLISH A QUALITY STANDARD FOR THE ARTICLE DESIRED. THE CONTRACTOR IS NOT
RESTRICTED TO THE USE OF THE SPECIFIC BRAND OF THE MANUFACTURER NAMED UNLESS SO
INDICATED IN THE SPECIFICATIONS.
E.THE ELECTRICAL CONTRACTOR SHALL FURNISH AND PRESENT FIVE (5) COPIES OF SHOP
DRAWINGS OR BROCHURES FOR ALL FIXTURES, EQUIPMENT, AND ACCESSORIES TO THE
ENGINEER FOR THE ENGINEER'S APPROVAL. CHECKING IS ONLY FOR GENERAL CONFORMANCE
WITH THE DESIGN CONCEPT OF THE PROJECT AND GENERAL COMPLIANCE SHOWN IS SUBJECT
TO THE REQUIREMENTS OF THE PLANS AND SPECIFICATIONS. CONTRACTOR IS RESPONSIBLE
FOR: DIMENSIONS WHICH SHALL BE CONFIRMED AND CORRELATED AT THE JOB SITE;
FABRICATION PROCESSES AND TECHNIQUES OF CONSTRUCTION; COORDINATION OF HIS WORK
WITH THAT OF ALL OTHER TRADES AND THE SATISFACTORY PERFORMANCE OF HIS WORK.
F.THE ELECTRICAL CONTRACTOR SHALL EXAMINE DRAWINGS RELATING TO WORK OF ALL TRADES
AND BECOME FULLY INFORMED AS TO EXTENT AND CHARACTER OF WORK REQUIRED AND ITS
RELATION TO ALL OTHER WORK IN THE PROJECT.
G.BEFORE SUBMITTING A BID, THE CONTRACTOR SHALL VISIT THE SITE AND EXAMINE ALL
ADJOINING EXISTING BUILDINGS, EQUIPMENT AND SPACE CONDITIONS ON WHICH HIS WORK IS IN
ANY WAY DEPENDENT FOR THE BEST WORKMANSHIP AND OPERATION ACCORDING TO THE
INTENT OF SPECIFICATIONS AND DRAWINGS. HE SHALL REPORT TO THE ARCHITECT ANY
CONDITION WHICH MIGHT PREVENT HIM FROM INSTALLING HIS EQUIPMENT IN THE MANNER
INTENDED.
H.NO CONSIDERATION OR ALLOWANCE WILL BE GRANTED FOR FAILURE TO VISIT SITE, OR FOR
ANY ALLEGED MISUNDERSTANDING OF MATERIALS TO BE FURNISHED OR WORK TO BE DONE.
I.EXISTING CONDUITS, PIPES, EQUIPMENT, ETC.: REFER TO DIVISION I FOR ADDITIONAL
REQUIREMENTS. EXISTING CONDUITS, PIPES, UTILITY LINES, TANKS, EQUIPMENT, OR OTHER
OBSTRUCTIONS, WHETHER UNDERGROUND, CONCEALED, OR EXPOSED, ARE NOT IN GENERAL
INDICATED ON DRAWINGS. PRIOR TO START OF WORK, HAVE EXISTING UTILITY OBSTRUCTIONS
CLEARLY MARKED BY UTILITIES LOCATOR SERVICE. PLAN WORK SO AS TO ROUTE AND LOCATE
ALL NEW WORK TO AVOID THESE OBSTRUCTIONS. REPAIR OR REPLACE, AT NO COST TO
OWNER, EXISTING INSTALLATIONS WHERE DAMAGED, THAT OCCURRED DURING THE COURSE OF
CONSTRUCTION.
END OF SECTION 16010
SECTION 16015
ELECTRICAL DRAWINGS AND REFERENCE SYMBOLS
A.THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERALLY THE LOCATIONS OF MATERIAL
AND EQUIPMENT. THESE DRAWINGS SHALL BE FOLLOWED AS CLOSELY AS POSSIBLE. THE
ELECTRICAL CONTRACTOR SHALL COORDINATE THE WORK UNDER THIS SECTION WITH THE
ARCHITECTURAL, STRUCTURAL, PLUMBING, HEATING AND AIR CONDITIONING, AND THE
DRAWINGS OF OTHER TRADES FOR EXACT DIMENSIONS, CLEARANCES AND ROUGHING-IN
LOCATIONS: THIS CONTRACTOR SHALL COOPERATE WITH ALL OTHER TRADES IN ORDER TO
MAKE MINOR FIELD ADJUSTMENTS TO ACCOMMODATE THE WORK OF OTHERS. DO NOT RELY ON
THE SCALE OF THE DRAWINGS FOR ROUGH-IN MEASUREMENTS, NOR USE THEM AS SHOP
DRAWINGS.
B.THE DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY, EACH TO THE OTHER, AND THE
WORK REQUIRED BY EITHER SHALL BE INCLUDED IN THE CONTRACT AS IF CALLED FOR BY BOTH.
C.IF DIRECTED BY THE ARCHITECT, THE CONTRACTOR SHALL, WITHOUT EXTRA CHARGE, MAKE
REASONABLE MODIFICATIONS IN THE LAYOUT AS NEEDED TO PREVENT CONFLICT WITH WORK
OF OTHER TRADES OR FOR PROPER EXECUTION OF THE WORK.
D.ELECTRICAL SYMBOLS USED ON THIS PROJECT ARE SHOWN IN A SYMBOL LIST ON THE
ACCOMPANYING WORKING DRAWINGS. THIS LIST SHOWS STANDARD SYMBOLS AND ALL MAY
NOT APPEAR ON THE PROJECT DRAWINGS; HOWEVER, WHEREVER THE SYMBOL ON PROJECT
DRAWINGS OCCURS, THE ITEM SHALL BE PROVIDED AND INSTALLED.
END OF SECTION 16015
SECTION 16020
WORK INCLUDED
A.THE SCOPE OF THE WORK CONSISTS OF ELECTRICAL INSTALLATION AT 617 WEST BLEEKER. THIS
SHALL INCLUDE, BUT NOT BE LIMITED TO; ELECTRICAL DISTRIBUTION; AND OTHER ITEMS AS
CALLED OUT ON THE DRAWINGS FOR THE AREAS OF WORK.THIS WORK WILL ALSO INCLUDE:
ELECTRICAL DISTRIBUTION INSTALLATION; POWERING OF MECHANICAL EQUIPMENT; AND OTHER
ITEMS AS CALLED OUT ON THE DRAWINGS FOR THE NEW CONSTRUCTION. THE ELECTRICAL
CONTRACTOR SHALL PROVIDE ALL SUPERVISION, LABOR, MATERIALS, EQUIPMENT, MACHINERY,
AND ANY AND ALL OTHER ITEMS NECESSARY TO COMPLETE THE SYSTEMS. THE ELECTRICAL
CONTRACTOR SHALL NOTE THAT ALL ITEMS OF EQUIPMENT ARE SPECIFIED IN THE SINGULAR;
HOWEVER, THE CONTRACTOR SHALL PROVIDE AND INSTALL THE NUMBER OF ITEMS OF
EQUIPMENT AS INDICATED ON THE DRAWINGS AND AS REQUIRED FOR COMPLETE SYSTEMS.
B.IT IS THE INTENTION OF THE SPECIFICATIONS AND DRAWINGS TO CALL FOR FINISHED WORK,
TESTED AND READY FOR OPERATION.
C.ANY APPARATUS, APPLIANCE, MATERIAL OR WORK NOT SHOWN ON DRAWINGS BUT MENTIONED
IN THE SPECIFICATIONS, OR VICE VERSA, OR ANY INCIDENTAL ACCESSORIES NECESSARY TO
MAKE THE WORK COMPLETE AND PERFECT IN ALL RESPECTS AND READY FOR OPERATION,
EVEN IF NOT PARTICULARLY SPECIFIED, SHALL BE FURNISHED, DELIVERED AND INSTALLED BY
THE CONTRACTOR WITHOUT ADDITIONAL EXPENSE TO THE OWNER. WITH SUBMISSION OF BID,
THE ELECTRICAL CONTRACTOR SHALL GIVE WRITTEN NOTICE TO THE ARCHITECT: ANY
MATERIALS OR APPARATUS BELIEVED INADEQUATE OR UNSUITABLE, IN VIOLATION OF LAWS,
ORDINANCES OR RULES; ANY NECESSARY ITEMS OR WORK OMITTED. IN THE ABSENCE OF SUCH
WRITTEN NOTICE, IT IS MUTUALLY AGREED THE CONTRACTOR HAS INCLUDED THE COST OF ALL
REQUIRED ITEMS IN HIS PROPOSAL, AND THAT HE WILL BE RESPONSIBLE FOR THE APPROVED
SATISFACTORY FUNCTIONING OF THE ENTIRE SYSTEM WITHOUT EXTRA COMPENSATION.
END OF SECTION 16020
SECTION 16030
CODES AND FEES
A.ALL MATERIALS AND WORKMANSHIP SHALL COMPLY WITH ALL APPLICABLE CODES,
SPECIFICATIONS, LOCAL ORDINANCES, INDUSTRY STANDARDS. UTILITY COMPANY AND FIRE
INSURANCE CARRIER'S REQUIREMENTS. CONTACT PROPER AUTHORITIES, OBTAIN AND PAY FOR
REQUIRED PERMITS, INSPECTIONS AND UTILITY SERVICE CONNECTIONS. DO NOT INCLUDE ANY
UTILITY COMPANY CHARGES THAT CAN BE BILLED DIRECTLY TO THE OWNER.
B.IN CASE OF DIFFERENCE BETWEEN THE BUILDING CODES, SPECIFICATIONS, STATE LAWS, LOCAL
ORDINANCES, INDUSTRY STANDARDS, UTILITY COMPANY REGULATIONS, FIRE INSURANCE
CARRIER'S REQUIREMENTS, AND THE CONTRACT DOCUMENTS, THE MOST STRINGENT SHALL
GOVERN. THE CONTRACTOR SHALL PROMPTLY NOTIFY THE ARCHITECT IN WRITING OF ANY
SUCH DIFFERENCE.
C.NONCOMPLIANCE: SHOULD THE CONTRACTOR PERFORM ANY WORK THAT DOES NOT COMPLY
WITH THE REQUIREMENTS OF THE APPLICABLE BUILDING CODES, STATE LAWS, LOCAL
ORDINANCES, INDUSTRY STANDARDS, FIRE INSURANCE CARRIER'S REQUIREMENTS, AND UTILITY
COMPANY REGULATIONS, HE SHALL BEAR THE COST ARISING IN CORRECTING ANY SUCH
DEFICIENCY.
END OF SECTION 16030
SECTION 16100
BASIC METHODS AND MATERIALS
SECTION 16101
GENERAL
A.PROTECTION: ALL WORK, MATERIALS AND EQUIPMENT SHALL BE COMPLETELY AND
ADEQUATELY PROTECTED AT ALL TIMES. PAY FOR ALL DAMAGE, INJURY OR LOSS, EXCEPT
SUCH AS MAY BE DIRECTLY DUE TO ERRORS IN THE CONTRACT DOCUMENTS OR BE CAUSED BY
AGENTS OR EMPLOYEES OF THE OWNER. POST EFFECTIVE DANGER SIGNS WARNING AGAINST
HAZARDS CREATED BY THE WORK.
B.TRENCHING AND BACKFILLING: PERFORM ALL TRENCHING AND BACKFILL REQUIRED BY WORK
UNDER THIS DIVISION OF THE SPECIFICATIONS. TRENCHING AND BACKFILLING SHALL BE DONE IN
ACCORDANCE WITH THE "SITE WORK" DIVISION OF THE SPECIFICATIONS AND AS HEREIN
SPECIFIED. THIS PORTION OF THE WORK SHALL BE EXECUTED UNDER THE DIRECT
SUPERVISION OF THE GENERAL CONTRACTOR. TRENCHES SHALL BE EXCAVATED TO THE
DEPTH REQUIRED FOR THE UTILITIES INVOLVED. THE TRENCH BOTTOM SHALL BE GRADED TRUE
AND FREE FROM DEBRIS, STONES AND SOFT SPOTS. WHERE DIRECT BURIAL CABLES ARE USED
FOUR INCHES OF FINE SAND SHALL BE PLACED IN THE BOTTOM OF THE TRENCH PRIOR TO
CABLE PLACEMENT.
C.EQUIPMENT, MATERIALS, INSTALLATION;
1.ALL EQUIPMENT, ACCESSORIES AND SPECIALTIES CONNECTED TO EQUIPMENT AND ALL ITEMS
OF MATERIAL SHALL BE INSTALLED AS RECOMMENDED BY THEIR MANUFACTURERS UNLESS
SPECIFICALLY STATED OTHERWISE.
2.PROVIDE PROPER SUPPORTS, MOUNTS, ETC., AS REQUIRED.
3.COORDINATE WITH THE GENERAL CONTRACTOR.
4.OBTAIN INSTRUCTIONS FROM THE ARCHITECT FOR INSTALLATION OF ITEMS NOT COMPLETELY
COVERED BY CONTRACT DOCUMENTS OR PUBLISHED MANUFACTURER'S RECOMMENDATIONS.
D.EQUIPMENT FINISH: ALL ELECTRICAL EQUIPMENT SHALL BE FURNISHED FACTORY PAINTED OR
FINISHED WITH TWO COATS OF HIGH GRADE ENAMEL AND IN THE MANUFACTURER'S STANDARD
COLORS UNLESS OTHERWISE SPECIFIED.
1.UNPAINTED EQUIPMENT AND MATERIALS, EXCEPT CONDUIT IN CONCEALED SPACES, SHALL BE
CLEANED AND PRIMED TO BE PAINTED BY THE PAINTING CONTRACTOR IN ACCORDANCE WITH
THE PAINTING SECTION OF THESE SPECIFICATIONS.
2.THE COLORS OF ALL EXPOSED ELECTRICAL MATERIAL AND APPARATUS SHALL BE AS
SELECTED BY THE OWNER.
E.CHASES, SLEEVES, CUTTING, PATCHING
1.PROVIDE FOR NECESSARY CHASES, HOLES, SLEEVES, BOXES, INSERTS AND HANGERS BY
ARRANGEMENT WITH CONTRACTORS OF THE OTHER APPROPRIATE TRADES. PROVIDE
"FLAMESEAL" OR OF THE APPROVED FIRESTOPPING MATERIAL AT ALL PENETRATIONS
THROUGH RATED WALLS, FLOORS AND CEILINGS.
2.PROVIDE FOR ALL CUTTING AND PATCHING OF HOLES, OPENINGS, AND NOTCHES. OBTAIN
WRITTEN APPROVAL OF THE ARCHITECT BEFORE NOTCHING, BORING, CHIPPING, BURNING,
DRILLING, WELDING TO STRUCTURAL MEMBERS.
F.INSPECTION
1.ALL WORK AND MATERIALS COVERED BY DRAWINGS AND SPECIFICATIONS SHALL BE SUBJECT
TO INSPECTION AT ANY AND ALL TIMES BY REPRESENTATIVES OF THE ARCHITECT AND
OWNER. IF ANY MATERIAL OR INSTALLATION DOES NOT CONFORM TO THE DRAWINGS AND
SPECIFICATIONS, WITHIN THREE DAYS AFTER BEING NOTIFIED BY THE ARCHITECT, REMOVE
THE MATERIALS FROM THE PREMISES AND CORRECT THE INSTALLATION TO THE
SATISFACTION OF THE ARCHITECT. ASSUME THE ENTIRE COST OF REMOVING AND REPLACING
THE MATERIAL AND CORRECTING THE INSTALLATION, INCLUDING CUTTING AND PATCHING
THAT MAY BE NECESSARY.
2.WORK SHALL NOT BE CLOSED IN NOR COVERED BEFORE INSPECTION AND APPROVAL BY THE
ARCHITECT. PROVIDE FOR UNCOVERING AND MAKING REPAIRS, AT NO EXTRA COST, WHEN
UNINSPECTED WORK HAS BEEN CLOSED IN. NOTIFY THE ARCHITECT WHEN WORK IS READY
FOR INSPECTION.
3.NOTIFY PROPER AUTHORITIES WHEN WORK IS READY FOR ANY INSPECTIONS REQUIRED BY
APPLICABLE CODES, RULES AND REGULATIONS, ALLOWING SUFFICIENT TIME FOR
INSPECTIONS TO BE MADE WITHOUT HINDERING PROGRESS OF THE WORK, AND FURNISH THE
OWNER, WITHOUT ADDITIONAL COSTS, PROPER CERTIFICATES OF ACCEPTANCE FROM SUCH
AUTHORITIES.
4.UPON COMPLETION OF ALL WORK AND ADJUSTMENT OF ALL EQUIPMENT, FINAL INSPECTION
SHALL BE MADE UNDER DIRECTION OF THE ARCHITECT. TEST AND OPERATE ALL DEVICES,
EQUIPMENT AND SYSTEMS TO DEMONSTRATE THAT THE ELECTRICAL SYSTEM IS COMPLETE
AND FUNCTIONAL IN THE MANNER REQUIRED.
G.CLEAN UP
1.DURING THE COURSE OF THE WORK REMOVE ANY MATERIALS NOT INSTALLED IN THE WORK
WHICH CONFLICT WITH THE WORK OF OTHERS IF SO DIRECTED BY THE ARCHITECT.
2.AT COMPLETION OF WORK CLEAN UP AND REMOVE FROM THE PREMISES ALL DEBRIS AND
MATERIALS NOT INSTALLED IN THE WORK SO THE PREMISES WILL BE LEFT CLEAN. WASH AND
WIPE CLEAN ALL LIGHTING FIXTURES AND LAMPS WHICH MAY HAVE BECOME SOILED DURING
INSTALLATION.
H.RECORD DRAWINGS: AT COMPLETION OF THE WORK FURNISH TO THE ARCHITECT TWO
COMPLETE SETS OF ELECTRICAL PRINTS MARKEFINDD TO SHOW THE WORK "AS-BUILT".
I.MAINTENANCE AND OPERATING PROCEDURES: UPON COMPLETION OF ALL WORK AND
ADJUSTMENT OF ALL EQUIPMENT, INSTRUCT THE OWNER ON THE CORRECT OPERATION AND
MAINTENANCE PROCEDURE FOR THE ELECTRICAL SYSTEM IN TOTAL. FURNISH 3 SETS OF TYPED
MAINTENANCE MANUALS CONTAINING CUT SHEETS ON ALL EQUIPMENT, TABLES OF FUSES AND
FOR WHAT EQUIPMENT, TABLE OF LAMPS AND BALLASTS AND FOR WHAT FIXTURES. INCLUDE A
LIST OF CONTACTS WITH PHONE NUMBERS FOR ALL SYSTEMS FOR OWNERS' USE, IN THE EVENT
THE ELECTRICAL SYSTEM REQUIRES SERVICE WORK WITHIN THE WARRANTY PERIOD.
J.GUARANTEE: GUARANTEE THAT ALL WORK GOVERNED BY THIS DIVISION SHALL BE NEW AND
FREE OF DEFECTIVE WORK, MATERIALS, AND COMPONENTS FOR A PERIOD OF ONE YEAR AFTER
WRITTEN ACCEPTANCE. REPAIR, REVISE AND REPLACE DEFECTS AS DIRECTED, WITH NO
ADDITIONAL COST TO THE OWNER. (INCANDESCENT LAMPS, FUSES AND ANY EXISTING
EQUIPMENT ARE EXEMPT).
END OF SECTION 16101
SECTION 16111
CONDUITS
A.PVC CONDUIT SHALL BE USED FOR ALL UNDERGROUND FEEDERS AND BRANCH CIRCUITS
UNLESS OTHERWISE DIRECTED ON PLANS OR AS APPROVED BY NEC. ALL CONDUIT SHALL BE UL
APPROVED.
B.CONDUIT SIZES SHALL BE AS INDICATED ON THE DRAWINGS, OR MINIMUM IN ACCORDANCE WITH
THE NEC, INCLUDING PROVISION FOR GREEN EQUIPMENT GROUNDING CONDUCTOR USING 3/4
INCH MINIMUM CONDUIT. THE USE OF 1/2 INCH CONDUIT ELSEWHERE MAY BE APPROVED IF
CONDITIONS WARRANT.
C.SPECIAL CONDUIT FITTINGS SHALL BE APPROPRIATE FOR EACH APPLICATION AND SHALL BE
MANUFACTURED BY T & B OR APPROVED EQUAL.
D.CONDUIT SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF THE
NEC AND SHALL BE INSTALLED IN A NEAT, WORKMANLIKE MANNER.
E.THE ENTIRE CONDUIT SYSTEM SHALL BE INSTALLED TO PROVIDE A CONTINUOUS BOND
THROUGHOUT THE SYSTEM.
F.ELECTRICAL METALLIC TUBING (EMT) MAY BE USED FOR BRANCH CIRCUITS AND RACEWAYS
OTHER THAN FOR SERVICE ENTRANCE AND MAIN FEEDERS UNLESS PROHIBITED BY THE NEC OR
LOCAL ORDINANCES. EMT SHALL BE UL APPROVED, GALVANIZED INSIDE AND OUTSIDE,
COMPLYING WITH ANSI C-80.3 FOR ZINC COATED EMT WITH FITTINGS OF THE SAME TYPE
MATERIAL AND FINISH, OF THE PRESSURE CONNECTED TYPE FOR EXTERIOR INSTALLATION AND
OF THE SET SCREW TYPE FOR INTERIOR INSTALLATION.
G.ALL CONDUIT JOINTS SHALL BE CUT SQUARE, REAMED SMOOTH, AND DRAWN UP TIGHT. BENDS
OR OFFSETS SHALL BE MADE WITH AN APPROVED BENDER OR HICKEY, OR HUB-TYPE CONDUIT
FITTINGS. NUMBER OF BENDS PER RUN SHALL CONFORM TO THE NEC LIMITATIONS.
H.CONCEALED CONDUITS SHALL BE RUN IN A DIRECT LINE WITH LONG SWEEP BENDS AND
OFFSETS. EXPOSED CONDUITS SHALL BE PARALLEL TO AND AT RIGHT ANGLES TO BUILDING
LINES, USING CONDUIT FITTINGS FOR ALL TURNS AND OFFSETS.
I.TRANSITIONS BETWEEN NONMETALLIC CONDUITS AND CONDUITS OF OTHER MATERIALS SHALL
BE MADE WITH THE MANUFACTURER'S STANDARD ADAPTERS DESIGNED FOR SUCH PURPOSE.
J.EXPOSED CONDUITS SHALL BE SECURELY FASTENED IN PLACE ON MAXIMUM 10 FOOT
INTERVALS; AND HANGERS, SUPPORTS OR FASTENERS SHALL BE PROVIDED AT EACH ELBOW
AND AT THE END OF EACH STRAIGHT RUN TERMINATING AT A BOX OR CABINET.
END OF SECTION 16111
SECTION 16120
WIRES AND CABLES
A.WIRE AND CABLE SHALL MEET ALL STANDARDS AND SPECIFICATIONS APPLICABLE, AND SHALL
BE IN CONFORMANCE WITH THE LATEST EDITION OF THE NEC. INSULATED WIRE AND CABLE
SHALL HAVE SIZE, TYPE OF INSULATION, VOLTAGE AND MANUFACTURER'S NAME PERMANENTLY
MARKED ON OUTER COVERING AT REGULAR INTERVALS NOT EXCEEDING FOUR FEET. WIRE AND
CABLE SHALL BE DELIVERED IN COMPLETE COILS OR REELS WITH IDENTIFYING TAGS, STATING
SIZE, TYPE OF INSULATION, ETC.
B.WIRE AND CABLE SHALL BE SUITABLY PROTECTED FROM WEATHER AND OTHER DAMAGE
DURING STORAGE AND HANDLING, AND SHALL BE IN FIRST CLASS CONDITION AFTER
INSTALLATION.
C.WIRE AND CABLE SHALL BE FACTORY COLOR CODED WITH A SEPARATE COLOR FOR EACH
PHASE AND NEUTRAL USED CONSISTENTLY THROUGHOUT THE SYSTEM. COLOR CODING SHALL
BE AS REQUIRED BY THE NEC.
D.ALL CONDUCTORS SHALL BE RATED 600 VOLTS, UNLESS OTHERWISE SPECIFIED OR SHOWN ON
THE DRAWINGS, OR FOR ELECTRONIC OR COMMUNICATION USE.
E.WIRE AND CABLE FOR VARIOUS APPLICATIONS SHALL BE AS FOLLOWS UNLESS OTHERWISE
DESIGNATED:
1.WIRE #10 AND SMALLER SHALL BE SOLID; WIRE #8 AND LARGER SHALL BE STRANDED.
2.#12 THRU #6 DRY LOCATIONS: TYPE THHN, 90 DEGREES C.
3.#12 THRU #6 IN SLABS, UNDERGROUND, OR WET LOCATIONS: TYPE THWN OR TYPE XHHW, 75
DEGREES C.
4.#4 AND LARGER: TYPE XHHW OR TYPE THWN 75 DEGREES C.
F.WIRE AND CABLE SHALL BE AS MANUFACTURED BY GENERAL ELECTRIC, ANACONDA WIRE &
CABLE, ROME CABLE, TRIANGLE CONDUIT & CABLE, OR APPROVED EQUAL. SUBSTITUTION OF
WIRE AND CABLE MANUFACTURER SHALL BE ONLY WITH THE APPROVAL OF THE
ARCHITECT/ENGINEER.
G.FOR ANY SPECIFIC USE NOT COVERED HERE ABOVE, COMPLY WITH THE NEC IN CONDUCTOR
USE.
H.ALL CIRCUITS SHALL BE 2#12 CU + G CU UNLESS OTHERWISE NOTED ON DRAWINGS OR IN
SCHEDULES.
I.ALL 15 AND 20 AMP CIRCUITS WITH LENGTHS OVER 150 FT. SHALL HAVE THEIR CONDUCTOR SIZE
INCREASED TO #10 FOR VOLTAGE DROP.
END OF SECTION 16120
SECTION 16121
WIRE CONNECTIONS
A.JOINTS ON BRANCH CIRCUITS SHALL OCCUR ONLY WHERE SUCH CIRCUIT DIVIDE AS INDICATED
ON PLANS AND SHALL CONSIST OF ONE THROUGH CIRCUIT TO WHICH SHALL BE SPLICED THE
BRANCH FROM THE CIRCUIT. IN NO CASE SHALL JOINTS IN BRANCH CIRCUITS BE LEFT FOR THE
FIXTURE HANGER TO MAKE. NO SPLICES SHALL BE MADE IN CONDUCTOR EXCEPT AT OUTLET
BOXES, JUNCTION BOXES, OR SPLICE BOXES.
B.ALL JOINTS OR SPLICES FOR #10 AWG OR SMALLER SHALL BE MADE WITH UL APPROVED WIRE
NUTS OR COMPRESSION TYPE CONNECTORS.
C.ALL JOINTS OR SPLICES FOR #8 AWG OR LARGER SHALL BE MADE WITH A MECHANICAL
COMPRESSION CONNECTOR. AFTER THE CONDUCTORS HAVE BEEN MADE MECHANICALLY AND
ELECTRICALLY SECURE, THE ENTIRE JOINT OR SPLICE SHALL BE COVERED WITH SCOTCH #33
TAPE OR APPROVED EQUAL TO MAKE THE INSULATION OF THE JOINT OR SPLICE EQUAL TO THE
INSULATION OF THE CONDUCTORS. THE CONNECTOR SHALL BE UL APPROVED.
END OF SECTION 16121
SECTION 16125
PULLING CABLES
A.INSTALL CONDUCTORS IN ALL RACEWAYS AS REQUIRED, UNLESS OTHERWISE NOTED, IN A NEAT
AND WORKMANLIKE MANNER. ALL EMPTY CONDUITS SHALL HAVE A #14 GALVANIZED PULL WIRE
OR NYLON PULLCORD LEFT IN PLACE FOR FUTURE USE.
B.CONDUCTORS SHALL BE COLOR CODED IN ACCORDANCE WITH THE NEC. MAINS, FEEDERS,
SUBFEEDERS SHALL BE TAGGED IN ALL PULL, JUNCTION, AND OUTLET BOXES AND IN THE
GUTTER OF PANELS WITH APPROVED CODE TYPE WIRE MARKERS.
C.NO LUBRICANT OTHER THAN POWDERED SOAPSTONE OR APPROVED PULLING COMPOUND MAY
BE USED TO PULL CONDUCTORS.
D.AT LEAST EIGHT (8) INCHES OF SLACK WIRE SHALL BE LEFT IN EVERY OUTLET BOX WHETHER IT
BE IN USE OR LEFT FOR FUTURE USE.
E.ALL CONDUCTORS AND CONNECTIONS SHALL TEST FREE OF GROUNDS, SHORTS AND OPENS
BEFORE TURNING THE JOB OVER TO THE OWNER.
F.PULL BOXES SHALL BE REQUIRED IN RUNS OVER 100 FEET OR WHEN
MORE THAN THREE 90-DEGREE BENDS ARE USED, OR AS INDICATED ON THE DRAWINGS.
G.FEEDERS ARE TO BE RUN ABOVE GROUND TO ALL POWER PANELS AND LIGHTING PANELS,
UNLESS INDICATED OTHERWISE ON DRAWINGS.
H.WHERE MOTORS HAVE CONDUIT TERMINAL BOXES, FEEDERS SHALL BE CONNECTED TO SAME
BY FLEXIBLE MEANS.
I.ALL MOTORS WITH SLIDING BASE MOUNTINGS SHALL HAVE NOT LESS THAN 18 INCHES NOR
MORE THAN 6 FEET OF CONDUIT CONNECTING RIGID CONDUIT FEED TO MOTOR TERMINAL BOX.
J.CONDUCTOR SPLICES SHALL BE MADE ONLY IN JUNCTION BOXES, TERMINAL BOXES, OR PULL
BOXES.
END OF SECTION 16125
SECTION 16133
OUTLET BOXES
ALL OUTLET BOXES FOR CONCEALED WIRING SHALL BE SHEET METAL,
A.GALVANIZED OR CADMIUM PLATED, AT LEAST 1 INCHES DEEP, SINGLE OR GANGED, OF SIZE TO
ACCOMMODATE DEVICES AND NUMBER OF CONDUCTORS NOTED. BOXES SHALL BE EQUIPPED
WITH PLASTER RING OR COVER AS NECESSARY. ALL OUTLET BOXES SHALL BE MANUFACTURED
BY STEEL CITY OR APPROVED EQUAL.
B.BOXES FOR EXPOSED WIRING SHALL BE MALLEABLE IRON, CADMIUM FINISH, OR CAST ALUMINUM
ALLOY, AS MANUFACTURED BY STEEL CITY, AND SHALL NOT BE LESS THAN 4 INCHES SQUARE BY
1 INCHES DEEP UNLESS OTHERWISE NOTED.
C.FIXTURE OUTLET BOXES SHALL BE MINIMUM 4 INCH OCTAGONAL AND, WHERE REQUIRED AS
OUTLET AND JUNCTION BOXES, THEY SHALL BE 4 11/16 INCHES BY 2 1/8 INCHES DEEP.
END OF SECTION 16133
SECTION 16190
SUPPORTING DEVICES
A.THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL METALLIC SUPPORTS AS
REQUIRED FOR THE PROPER INSTALLATION OF RACEWAY SYSTEMS AND ALL OTHER EQUIPMENT
INSTALLED UNDER THIS DIVISION OF THE CONTRACT CONFORMING TO THE LATEST EDITION OF
THE NEC.
B.CONDUIT SHALL BE SUPPORTED ON APPROVED TYPES OF WALL BRACKETS, CEILING TRAPEZES,
STRAP HANGERS OR PIPE SUPPORTS, SECURED BY MEANS OF TOGGLE BOLTS IN HOLLOW
MASONRY WALLS OR UNITS. EXPANSION BOLTS WILL BE USED IN CONCRETE OR BLOCK,
MACHINE SCREWS ON METAL SURFACES, AND WOOD SCREWS ON WOOD CONSTRUCTION.
C.CONDUIT SHALL BE SECURELY FASTENED TO ALL SHEET METAL OUTLETS, JUNCTION AND PULL
BOXES WITH TWO GALVANIZED LOCKNUTS AND BUSHING, CARE BEING TAKEN TO SEE THAT THE
FULL NUMBER OF THREADS PROJECT THROUGH TO PERMIT THE BUSHING TO BE DRAWN TIGHT
AGAINST THE END OF THE CONDUIT, AFTER WHICH THE LOCKNUTS SHALL BE MADE TIGHT
SUFFICIENTLY TO DRAW THEM INTO FIRM ELECTRICAL CONTACT WITH THE OUTLET BOX.
INSTALL A PLASTIC BUSHING ON END OF PIPE THREADS PROTRUDING INTO JUNCTION BOXES
AND OTHER ENCLOSURES TO PROTECT CABLING.
D.THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SUPPORTS REQUIRED FOR
THE ELECTRICAL EQUIPMENT AND CONDUIT.
END OF SECTION 16190
SECTION 16195
ELECTRICAL IDENTIFICATION
A.THE ELECTRICAL CONTRACTOR SHALL MAINTAIN ACCURATE RECORDS OF ALL DEVIATIONS IN
WORK AS ACTUALLY INSTALLED FROM WORK INDICATED ON THE DRAWINGS. UPON
COMPLETION OF THE PROJECT, TWO (2) COMPLETE SETS OF MARKED-UP PRINTS SHALL BE
DELIVERED TO THE ARCHITECT.
B.IDENTIFICATION OF EQUIPMENT
1.PROVIDE AND INSTALL LAMINATED BLACK AND WHITE LAMACOID NAMEPLATES FOR ALL
SERVICE SWITCHES, DISTRIBUTION SWITCHES, DISTRIBUTION SWITCHBOARDS, BRANCH
CIRCUIT PANELBOARDS, SAFETY SWITCHES, CABINETS, STARTERS, AND OTHER EQUIPMENT
WITH THEIR CORRECT DESIGNATION. LABEL EQUIPMENT IN AREAS ACCESSIBLE TO THE
PUBLIC ON INSIDE OF ENCLOSURE ONLY. NAMEPLATES SHALL BE FIRMLY SECURED TO FRONT
COVER OR DOOR WITH TWO PROPERLY SIZED POP RIVETS.
2.MOUNT A TYPEWRITTEN DIRECTORY BEHIND PLASTIC ON THE INSIDE OF EACH BRANCH
CIRCUIT PANEL DOOR, GIVING THE NUMBER, DESCRIPTION AND LOCATION OF THE CIRCUIT
CONTROLLED BY EACH CIRCUIT BREAKER. REVISE EXISTING DIRECTORIES TO REFLECT
CIRCUIT MODIFICATIONS UNDER THIS CONTRACT.
3.ALL FUSED SAFETY SWITCHES AND FUSED SWITCH UNITS IN SWITCHBOARDS SHALL
INDIVIDUALLY BEAR A FUSE LABEL SHOWING PROPER SIZE AND TYPE OF FUSE TO BE USED.
4.INSTALL WIRING DIAGRAMS ON THE INSIDE COVER OF ALL STARTERS, SWITCHES AND OTHER
SUCH EQUIPMENT. SUCH DIAGRAMS SHALL NOT BE HANDWRITTEN.
5.ALL JUNCTION BOXES WITH BLANK COVERS SHALL HAVE CIRCUITS CONTAINED THEREIN
IDENTIFIED BY MEANS OF PERMANENT BLACK "MAGIC MARKER" ON THE COVER.
END OF SECTION 16195
SECTION 16199
ELECTRONIC EQUIPMENT
A.THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION AND
CONNECTION OF A PROPER POWER SUPPLY TO ALL ELECTRONIC EQUIPMENT FURNISHED BY
OTHERS. HE SHALL VERIFY ALL VOLTAGE, FREQUENCY, ETC., REQUIREMENTS PRIOR TO
ENERGIZING THE CIRCUIT. THOSE INSTALLING THE EQUIPMENT WILL BE RESPONSIBLE FOR THE
PROPER OPERATION OF THE EQUIPMENT PROVIDED THE PROPER POWER SUPPLY CIRCUIT IS
INSTALLED BY THE ELECTRICAL CONTRACTOR.
B.PROVIDE TELEPHONE LINES TO EQUIPMENT CONTROL PANELS WITH MODEM ACCESS.
COORDINATE WITH MECHANICAL CONTRACTOR.
END OF SECTION 16199
SECTION 16400
SERVICE AND DISTRIBUTION
SECTION 16401
GENERAL
A.THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL RELATED DISTRIBUTION
EQUIPMENT AS INDICATED ON THE FLOOR PLAN, DIAGRAMS, SCHEDULES, AND NOTES. ALL
EQUIPMENT SHALL BE NEW AND UL LISTED.
B. RELATED DOCUMENTS: DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING
GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 1 SPECIFICATIONS SECTION, APPLY
TO WORK OF THIS SECTION.
END OF SECTION 16401
SECTION 16440
DISCONNECT SWITCHES
A.THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL SAFETY SWITCHES AS INDICATED
ON THE DRAWINGS OR AS REQUIRED. ALL
SAFETY SWITCHES SHALL BE UL LISTED.
1.THE SWITCHES SHALL BE FUSED SAFETY SWITCHES (FSS) OR NON-FUSED SAFETY SWITCHES
(NFSS) AS SHOWN ON THE DRAWINGS OR REQUIRED AND SHALL BE MANUFACTURED BY
SIEMENS, SQUARE D, OR APPROVED EQUAL.
2.SWITCHES SHALL HAVE A QUICK-MAKE AND QUICK-BREAK OPERATING HANDLE AND
MECHANISM WHICH SHALL BE AN INTEGRAL PART OF THE BOX. PADLOCKING PROVISIONS
SHALL BE PROVIDED FOR PADLOCKING IN THE OFF POSITION WITH AT LEAST THREE
PADLOCKS. SWITCHES SHALL BE HORSEPOWER RATED FOR 250 VOLTS AC OR DC OR 600
VOLTS AC AS REQUIRED. LUGS SHALL BE UL LISTED FOR COPPER AND ALUMINUM CABLE.
3.SWITCHES SHALL BE FURNISHED IN NEMA I GENERAL PURPOSE ENCLOSURES WITH
KNOCKOUTS UNLESS OTHERWISE NOTED OR REQUIRED. SWITCHES LOCATED ON THE
EXTERIOR OF THE BUILDING OR IN "WET" LOCATIONS SHALL HAVE NEMA 3R ENCLOSURES
(WP).
4.THE SAFETY SWITCHES SHALL BE SECURELY MOUNTED IN ACCORDANCE WITH THE NEC. THE
CONTRACTOR SHALL PROVIDE ALL MOUNTING MATERIALS AND INSTALL FUSES IN THE FSS.
THE FUSES SHALL BE DUAL ELEMENT ON MOTOR CIRCUITS.
END OF SECTION 16440
SECTION 16450
GROUNDING
A.THE CONDUIT SYSTEMS AND NEUTRAL CONDUCTOR FOR THE WIRING SYSTEM, AND THE
TELEPHONE SYSTEM SHALL BE SECURELY GROUNDED. THE GROUNDS SHALL BE NEC GROUNDS
IN EACH CASE.
B.A GROUND SHALL BE ESTABLISHED AND TESTS CARRIED OUT TO INDICATE THAT SATISFACTORY
GROUND HAS BEEN ESTABLISHED IN ACCORDANCE WITH THE NEC.
C.WRITTEN RESULTS OF THIS TEST SHALL BE FORWARDED TO THE ENGINEER BEFORE
CONNECTION TO THE SERVICE.
END OF SECTION 16450
SECTION 16470
PANELBOARDS
A.FURNISH AND INSTALL DISTRIBUTION AND POWER PANELBOARDS AS INDICATED IN THE
PANELBOARD SCHEDULE AND WHERE SHOWN ON THE DRAWINGS. PANELBOARDS SHALL BE
DEAD-FRONT SAFETY TYPE, EQUIPPED WITH QUICK-MAKE, QUICK-BREAK FUSIBLE BRANCH
SWITCHES AND APPROVED FOR SERVICE ENTRANCE. THE ACCEPTABLE MANUFACTURERS OF
THE PANELBOARD ARE SIEMENS, SQUARE D, AND GE, PROVIDED THEY ARE FULLY EQUAL TO
THE TYPE LISTED ON THE DRAWINGS. THE PANELBOARD SHALL BE UL LISTED AND BEAR THE UL
LABEL.
B.ALL FUSIBLE BRANCH SWITCHES SHALL BE QUICK-MAKE, QUICK BREAK, WITH VISIBLE BLADES
AND DUAL HORSEPOWER RATINGS SWITCH HANDLES SHALL PHYSICALLY INDICATE ON AND OFF
POSITIONS. SUCH HANDLES SHALL ALSO BE ABLE TO ACCEPT THREE PADLOCKS HAVING
HEAVY-DUTY INDUSTRIAL TYPE SHACKLES. COVERS SHALL BE INTERLOCKED WITH THE SWITCH
HANDLES TO PREVENT OPENING IN THE ON POSITION. A MEANS SHALL BE PROVIDED TO ALLOW
AUTHORIZED PERSONNEL TO RELEASE THE INTERLOCK FOR INSPECTION PURPOSES WHEN A
SWITCH IS ON. A CARDHOLDER, PROVIDING CIRCUIT IDENTIFICATION, SHALL BE MOUNTED ON
EACH BRANCH SWITCH. SWITCHES SHALL BE PROVIDED WITH FUSES OR AS NOTED ON THE
DRAWINGS.
C.PANELBOARD BUS STRUCTURE AND MAIN LUGS OR MAIN SWITCH SHALL HAVE CURRENT
RATINGS AS SHOWN ON THE PANELBOARD SCHEDULE. THE BUS STRUCTURE SHALL
ACCOMMODATE PLUG-ON OR BOLTED BRANCH SWITCHES AND MOTOR STARTERS AS INDICATED
IN THE PANELBOARD SCHEDULE WITHOUT MODIFICATION TO THE BUS ASSEMBLY. PROVIDE
SOLID NEUTRAL ASSEMBLY (S/N).
D.SWITCHES AND PANELBOARD BUS STRUCTURE SHALL SAFELY AND WITHOUT FAILURE
WITHSTAND SHORT CIRCUITS ON THE SYSTEMS CAPABLE OF DELIVERING UP TO 100,000
AMPERES RMS SYMMETRICAL, UNLESS OTHERWISE NOTED.
E.PANELBOARD ASSEMBLY SHALL BE ENCLOSED IN A STEEL CABINET. THE RIGIDITY AND GAUGE
OF STEEL TO BE AS SPECIFIED IN UL STANDARD FOR CABINETS. THE SIZE OF WIRING GUTTERS
SHALL BE IN ACCORDANCE WITH UL STANDARD. CABINETS SHALL BE EQUIPPED WITH A FRONT
DOOR AND HAVE FULLY CONCEALED, SELF-ALIGNING TRIM CLAMPS. FRONTS SHALL BE
FULL-FINISHED STEEL WITH RUST INHIBITING PRIMER AND BAKED ENAMEL FINISH.
F.TERMINALS FOR FEEDER CONDUCTORS TO THE PANELBOARD MAINS AND NEUTRAL SHALL BE
SUITABLE FOR THE TYPE OF CONDUCTOR SPECIFIED. TERMINALS FOR BRANCH CIRCUIT WIRING,
BOTH BREAKER AND NEUTRAL, SHALL BE SUITABLE FOR THE TYPE OF CONDUCTOR SPECIFIED.
G. BEFORE INSTALLING PANELBOARDS CHECK ALL OF THE ARCHITECTURAL DRAWINGS FOR
POSSIBLE CONFLICT OF SPACE AND ADJUST THE LOCATION OF THE PANELBOARD TO PREVENT
SUCH CONFLICT WITH OTHER ITEMS.
H.THE PANELBOARDS SHALL BE MOUNTED IN ACCORDANCE WITH THE NEC. THE ELECTRICAL
CONTRACTOR SHALL FURNISH ALL MATERIAL FOR MOUNTING THE PANELBOARDS.
END OF SECTION 16470
SECTION 16471
BRANCH CIRCUIT PANELBOARD
A.POWER AND LIGHTING PANELS SHALL BE OF THE DEAD-FRONT, SAFETY TYPE, WITH THERMAL
MAGNETIC, QUICK-MAKE, QUICK-BREAK, TRIP FREE, BOLTED-TYPE MOLDED CASE CIRCUIT
BREAKERS. VOLTAGE RATINGS, NUMBER OF POLES, FRAME SIZE, TRIP RATINGS, MAIN BREAKER
OR LUGS, NEUTRAL BUS, AND GROUND BUS ARE ALL AS SHOWN ON THE DRAWINGS. BUS BARS
SHALL BE RECTANGULAR, SOLID COPPER, SECURELY MOUNTED AND BRACED. ALL
CONNECTIONS TO BUS BARS SHALL BE SECURELY BOLTED. CABINET BOXES SHALL BE
CONSTRUCTED OF CODE GRADE GALVANIZED STEEL, SIZED TO PROVIDE MINIMUM 4-INCH WIDE
WIRING GUTTERS ON SIDES, TOP AND BOTTOM. FRONTS SHALL BE CONSTRUCTED OF CODE
GRADE STEEL, ADJUSTABLE INDICATING TRIM CLAMPS AND WITH DOOR PROVIDED WITH
CONCEALED HINGES AND CYLINDER TYPE LOCK AND CATCH. TWO KEYS PER PANEL SHALL BE
FURNISHED, AND ALL LOCKS KEYED ALIKE. FRONT SHALL BE FINISH PAINTED BLUE-GRAY.
B. POWER PANELS SHALL BE SIEMENS, TYPE S1, S2, S3, SE, OR ENGINEER APPROVED EQUAL, WITH
BRANCH BREAKERS, MAIN BREAKERS OR LUGS, NEUTRAL AND GROUND BUSES, ETC., ALL AS
SHOWN ON THE DRAWINGS.
C. POWER AND LIGHTING PANEL CONSTRUCTION DETAILS SHALL BE IN ACCORDANCE WITH UL
STANDARDS AND SHALL CONFORM TO NEMA STANDARDS. THEY SHALL BEAR THE UL LABEL.
PANELS SHALL MEET FEDERAL SPECIFICATIONS W-P-115A, TYPE 1, CLASS I.
D. ALL PANEL DIRECTORIES SHALL BE TYPED AND TERMINOLOGY APPROVED BY THE OWNER.
END OF SECTION 16471
SECTION 16475
OVERCURRENT PROTECTIVE DEVICES
A.THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL WHERE INDICATED ON THE
DRAWINGS OR AS REQUIRED BY THE NEC MOLDED CASE CIRCUIT BREAKERS IN A NEMA TYPE 1
ENCLOSURE. BREAKERS SHALL BE MANUALLY OPERATED, TRIP-FREE AND DESIGNED SO THAT
ALL POLES OPEN SIMULTANEOUSLY. TRIPPING MECHANISM SHALL BE (THERMALLY,
MAGNETICALLY) OPERATED, SHALL OPEN INSTANTANEOUSLY ON SHORT CIRCUITS AND HAVE
TIME DELAY ON OVERLOADS, AND HAVE EFFECTIVE SCALING AGAINST TAMPERING. BREAKERS
SHALL BE AS CALLED FOR ON THE DRAWINGS OR IN THE PANELBOARD SCHEDULE AND AS
MANUFACTURED BY SIEMENS, SQUARE D, OR APPROVED EQUAL.
B. FUSES, UNLESS INDICATED OTHERWISE, SHALL BE DUAL ELEMENT, TIME LAG, CARTRIDGE TYPE
AS MANUFACTURED BY BUSSMAN. FUSES FOR MOTOR CIRCUITS SHALL BE SIZED IN
ACCORDANCE WITH THE NEC. LABELS INDICATING THE SIZE AND TYPE OF REPLACEMENT FUSES
SHALL BE GLUED TO INSIDE OF DOOR ON ALL FUSIBLE SWITCHES AND PANELBOARDS.
C. ALL FUSES SHALL BE OF THE CURRENT AND VOLTAGE RATING AS REQUIRED OR INDICATED.
D.SPARES: SPARE FUSES AMOUNTING TO 10% (MINIMUM THREE) OF EACH TYPE AND RATING
SHALL BE SUPPLIED BY THE ELECTRICAL CONTRACTOR. THESE SHALL BE TURNED OVER TO THE
OWNER UPON PROJECT COMPLETION.
END OF SECTION 16475
SECTION 16900
CONTROLS AND INSTRUMENTATION
SECTION 16901
GENERAL
A. ALL EQUIPMENT AND MATERIALS USED IN RELATION TO CONTROL WORK FOR THE PROJECT
SHALL BE NEW AND SHALL BEAR THE MANUFACTURER'S NAME AND TRADE NAME. THE
EQUIPMENT AND MATERIAL SHALL BE ESSENTIALLY THE STANDARD PRODUCT OF A
MANUFACTURER REGULARLY ENGAGED IN THE PRODUCTION OF THE REQUIRED TYPE OF
EQUIPMENT AND SHALL BE THE MANUFACTURER'S LATEST APPROVED DESIGN.
B.THE ELECTRICAL CONTRACTOR SHALL RECEIVE AND PROPERLY STORE THE EQUIPMENT AND
MATERIAL PERTAINING TO THE ELECTRICAL WORK. THE EQUIPMENT SHALL BE TIGHTLY
COVERED AND PROTECTED AGAINST DIRT, WATER, CHEMICAL OR MECHANICAL INJURY AND
THEFT. THE MANUFACTURER'S DIRECTIONS SHALL BE FOLLOWED COMPLETELY IN THE
DELIVERY, STORAGE, PROTECTION AND INSTALLATION OF ALL EQUIPMENT AND MATERIALS.
C. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL ITEMS NECESSARY FOR THE
COMPLETE INSTALLATION OF THE EQUIPMENT AS RECOMMENDED OR AS REQUIRED BY THE
MANUFACTURER OF THE EQUIPMENT OR REQUIRED BY CODE WITHOUT ADDITIONAL COST TO
THE OWNER, REGARDLESS OF WHETHER THE ITEMS ARE SHOWN ON THE PLANS OR COVERED IN
THE SPECIFICATIONS.
D.IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO CLEAN THE ELECTRICAL
EQUIPMENT, MAKE NECESSARY ADJUSTMENTS AND PLACE THE EQUIPMENT INTO OPERATION
BEFORE TURNING EQUIPMENT OVER TO OWNER. ANY PAINT THAT WAS SCRATCHED DURING
CONSTRUCTION SHALL BE "TOUCHED-UP" WITH FACTORY COLOR PAINT TO THE SATISFACTION
OF THE ARCHITECT. ANY ITEMS THAT WERE DAMAGED DURING CONSTRUCTION SHALL BE
REPLACED.
E.GENERAL
1.UNLESS OTHERWISE INDICATED ALL HEATING, VENTILATING, AIR CONDITIONING, PLUMBING,
AND OTHER MECHANICAL EQUIPMENT, MOTORS, AND CONTROLS SHALL BE FURNISHED, SET IN
PLACE AND WIRED AS FOLLOWS:
RESPONSIBLE DIVISION
ITEM FURNISHED SET POWER- CONTROL-
WIRED WIRED
EQUIPMENT ....23 23 26 --
COMBINATION MAGNETIC MOTOR
STARTERS, MAGNETIC MOTOR
STARTERS AND CONTACTORS .23 26 26 23
FUSED AND UNFUSED
DISCONNECT SWITCHES,
THERMAL OVERLOAD SWITCHES
AND HEATERS, MANUAL MOTOR
STARTERS ....26(1)26(1)26 --
MANUAL-OPERATING AND
MULTI-SPEED SWITCHES ..23 26 26 26
CONTROLS, RELAYS,
TRANSFORMERS ...23 23 26 23
THERMOSTATS (LOW VOLTAGE)
AND TIME SWITCHES ...23 23 26 23
THERMOSTATS (LINE VOLTAGE).23 23 26 26
TEMPERATURE CONTROL PANELS .23 23 26 23
MOTOR AND SOLENOID VALVES,
DAMPER MOTORS, PE & EP
SWITCHES .....23 23(2) -- 23(2)
PUSH-BUTTON STATIONS AND
PILOT LIGHTS ....23 23(2) -- 23(2)
HEATING, COOLING, VENTILATION
AND AIR CONDITIONING CONTROLS 23 23 26 23
EXHAUST FAN SWITCHES ..23 26 26 23(2)
SUBSCRIPT FOOTNOTES:
1) UNDER DIVISION 23 IF FURNISHED FACTORY-WIRED AS PART
OF EQUIPMENT OR IF FURNISHED WITH COMBINATION
STARTERS.
2) IF ITEM IS FOR LINE VOLTAGE, SET IN PLACE AND CONNECT
UNDER DIVISION 26. WHERE FACTORY MOUNTED ON EQUIPMENT
OR ATTACHED TO PIPING OR DUCTS AND USING LINE VOLTAGE
FURNISH AND SET UNDER DIVISION 23, CONNECT UNDER
DIVISION 26.
2.VERIFY LOCATION AND NAMEPLATE DATA OF ALL MECHANICAL EQUIPMENT WITH THE
MECHANICAL CONTRACTOR PRIOR TO INSTALLING ELECTRICAL FACILITIES. BE RESPONSIBLE
FOR COORDINATION OF REVISIONS AND MODIFICATIONS NECESSARY TO PROPERLY SUPPLY
ELECTRICAL FACILITIES TO HEATING, VENTILATING, AIR CONDITIONING, PUMPS, MOTORS,
CONTROLS, AND OTHER MECHANICAL EQUIPMENT INSTALLED IN PLACE OF EQUIPMENT
SPECIFIED. REQUIRED ELECTRICAL FACILITIES CHANGES SHALL BE CONSIDERED TO BE A
PART OF THE MECHANICAL CONTRACT.
3.PROVIDE EACH MOTOR WITH A HORSEPOWER RATED DISCONNECT SWITCH AND MOTOR
RUNNING OVERCURRENT PROTECTION PER N.E.C. 430-37. TO FACILITATE EASE AND SAFETY
OF OPERATION AND MAINTENANCE OF MECHANICAL EQUIPMENT, LOCATE THE DISCONNECT
SWITCH IMMEDIATELY ADJACENT TO THE MOTOR, UNLESS OTHERWISE INDICATED. SIZE
THERMAL OVERLOAD HEATER UNITS FOR APPROXIMATELY 115% OF FULL LOAD MOTOR
CURRENT. SIZE FUSES IN ACCORDANCE WITH THE ACTUAL MOTOR NAMEPLATE RATING AND
AS RECOMMENDED BY THE BUSSMAN MFG. CO. CHECK AND COORDINATE ALL STARTERS,
FUSES, AND OTHER MOTOR-RUNNING PROTECTIVE DEVICES WITH THE EQUIPMENT THEY
CONTROL, AND PROVIDE AND INSTALL THE CORRECT SIZE PROTECTIVE ELEMENTS AS
REQUIRED.
4. DO NOT CONNECT MOTORS WHICH ARE OF A VOLTAGE RATING DIFFERENT THAN SUPPLY
VOLTAGE. REPORT SAME TO THE ARCHITECT IN WRITING AND OBTAIN WRITTEN
INSTRUCTIONS FOR RESOLUTION.
5.USE FLEXIBLE CONDUIT FOR ALL CONNECTIONS TO DEVICES DIRECTLY ATTACHED TO DUCTS,
PIPING AND MECHANICAL EQUIPMENT.
END OF SECTION 16901
SECTION 16950
TESTING
A.AS SOON AS ELECTRIC POWER IS AVAILABLE AND CONNECTED TO SERVE THE EQUIPMENT IN
THE BUILDING, AND EVERYTHING IS READY FOR FINAL TESTING AND PLACING IN SERVICE, A
COMPLETE OPERATIONAL TEST SHALL BE MADE. THE CONTRACTOR SHALL FURNISH ALL
NECESSARY INSTRUMENTS AND EQUIPMENT AND MAKE ALL TESTS, ADJUSTMENTS, AND TRIAL
OPERATIONS REQUIRED TO PLACE THE SYSTEM IN BALANCED AND SATISFACTORY OPERATING
CONDITION; FURNISH ALL NECESSARY ASSISTANCE AND INSTRUCTIONS TO PROPERLY
INSTRUCT THE OWNER'S AUTHORIZED PERSONNEL IN THE OPERATION AND CARE OF THE
SYSTEM.
B. PRIOR TO TESTING THE SYSTEM, THE FEEDERS AND BRANCH CIRCUITS SHALL BE CONTINUOUS
FROM MAIN FEEDERS TO MAIN PANELS, TO SUBPANELS, TO OUTLETS, WITH ALL BREAKERS AND
FUSES IN PLACE. THE SYSTEM SHALL BE TESTED FREE FROM SHORTS AND GROUNDS. SUCH
TESTS SHALL BE MADE IN THE PRESENCE OF THE ENGINEER'S REPRESENTATIVE.
C. NO CIRCUITS SHALL BE ENERGIZED WITHOUT THE OWNER'S APPROVAL.
D.THE RIGHT IS RESERVED TO INSPECT AND TEST ANY PORTION OF THE EQUIPMENT AND/OR
MATERIALS DURING THE PROGRESS OF ITS ERECTION. THE CONTRACTOR SHALL FURTHER
TEST ALL WIRING AND CONNECTIONS FOR CONTINUITY AND GROUNDS BEFORE CONNECTING
ANY FIXTURES OR EQUIPMENT.
E.THE CONTRACTOR SHALL TEST THE ENTIRE SYSTEM IN THE PRESENCE OF THE ARCHITECT OR
HIS ENGINEER WHEN THE SYSTEM IS FINALLY COMPLETED TO INSURE THAT ALL PORTIONS ARE
FREE FROM SHORT CIRCUITS OR GROUND FAULTS.
END OF SECTION 16950
SECTION 16980
DEMONSTRATION OF ELECTRICAL EQUIPMENT
A.THE ELECTRICAL CONTRACTOR SHALL PROVIDE THE ARCHITECT WITH CERTIFICATION OF THE
INSPECTION AND APPROVAL OF AN ACTIVE MEMBER OF THE INTERNATIONAL ASSOCIATION OF
ELECTRICAL INSPECTORS OF ALL WORK COMPLETED AND INCLUDED IN THE SECTION, IF
REQUIRED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING THE INSPECTOR WHEN
WORK REACHES INSPECTION STAGE.
B.THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING THE LOCAL AUTHORITY
HAVING JURISDICTION IN ORDER THAT LOCAL INSPECTION MAY BE CARRIED OUT AT THE
PROPER STAGE.
C.THE ELECTRICAL CONTRACTOR SHALL PAY FOR ALL PERMITS, INSPECTION FEES, AND
INSTALLATION FEES AS REQUIRED TO COMPLETE THE WORK UNDER THIS SECTION OF THE
CONTRACT.
D.THIS CONTRACTOR SHALL GUARANTEE THE MATERIALS AND WORKMANSHIP FOR A PERIOD OF
TWELVE (12) MONTHS FROM THE TIME THE INSTALLATION IS ACCEPTED BY THE OWNER. IF,
DURING THIS TIME, ANY DEFECTS SHOULD SHOW UP DUE TO ANY DEFECTIVE MATERIALS,
WORKMANSHIP, NEGLIGENCE OR WANT OF PROPER CARE ON THE PART OF THIS CONTRACTOR,
HE SHALL FURNISH ANY NEW MATERIALS AS NECESSARY, REPAIR SAID DEFECTS, AND PUT THE
SYSTEM IN ORDER AT HIS OWN EXPENSE ON RECEIPT OF NOTICE OF SUCH DEFECTS FROM THE
ARCHITECT. THIS SPECIFICATION IS NOT INTENDED TO IMPLY THAT THE ELECTRICAL
CONTRACTOR SHALL BE RESPONSIBLE FOR NEGLIGENCE OF THE OWNER.
END OF SECTION 16980
END OF DIVISION
GENERAL CONTRACTOR
Janckila Construction Inc.
75 Buckskin Drive
Carbondale, CO 81623
T 970.963.7239
F 970.963.7239
STRUCTURAL ENGINEER
Albright and Associates
402 Park Ave., Unit A
Basalt, CO 81621
T 970.927.4363
CIVIL ENGINEER
Roaring Fork Engineering
592 Highway 133,
Carbondale, CO 81623
T 970.948.7474
MEP ENGINEER
Bighorn Consulting Enginners, Inc.
386 Indian Road
Grand Junction, CO 81501
T 970.241.8709
ACOUSTIC CONSULTANT
Acentech
33 Moulton Street
Cambridge, MA 02138
T 617.499.8000
F 617.499.8074
61
7
W
E
S
T
B
L
E
E
K
E
R
S
T
R
E
E
T
AS
P
E
N
AS
P
E
N
,
C
O
8
1
6
1
1
Drawing Title:
Drawing No:
Phase:
Architect
29 Stanhope Street
3rd Floor
Boston, MA 02116
T 617.426.0995
F 617.426.0998
MONICA PONCE DE LEON
STUDIO, INC.
DATE & ISSUE DESCRIPTION BY CHECK
ISSUE/
REVISION
Project Number:
19-046
RE
S
I
D
E
N
C
E
09/19/2019 PERMIT SET BHCE BHCE1
SCHEDULES & DETAILS
E2-6
ELECTRICAL
2019-09-19
11/20/2019
01/28/2020
tonyf