File Documents.205 E Durant Ave.0127-2023-BRES (19)
THE RSIC-1 SOUND ISOLATION CLIP PAC International, Inc. Tel: (503) 649-7700 Fax: (503) 649-2710 www.pac-intl.com RSIC-1 wall assemblies vs. Generic wall assemblies The RSIC-1 wall systems give you a higher performing wall, while saving you money and reducing the wall thickness. The RSIC-1 wall systems are the highest performing wall systems per dollar spent. RSIC-1 WOOD WALL ASSEMBLIES 1 & 2 HOUR: STC 63 2x4 stud wall, RSIC-1, Drywall furring channel, R-19 insulation, 2 layers one side, 3 layers other side 5/8” gypsum board UL U301, U305, U309, U311, U331, U334 STC 62 2x4 stud wall, RSIC-1, Drywall furring channel, R-19 insulation, 2 layers 5/8” gypsum board each side UL U301, U305, U309, U311, U331, U334 STC 60 2x4 stud wall, RSIC-1, Drywall furring channel, R-19 insulation, 1 layer 5/8” gypsum board, 2 layers 5/8” gypsum board UL U305 U309 U311 U331 STC 56 2x4 stud wall, RSIC-1, Drywall furring channel, 3.5”insulation, 1 layer 5/8” gypsum board each side UL U305 U309 U311 U331 GENERIC WOOD WALL SYSTEMS STC 59 2x4 double stud wall, 3.5”insulation, 2 layers 5/8” gypsum board each side STC 56 2x4 double stud wall, 3.5”insulation, 1 layer 5/8” gypsum board each side STC 51 2x4 stagger stud wall, RC-1 channel, 3.5”insulation, 1 layer 5/8” gypsum board each side STC 47 2x4 stagger stud wall, 3.5”insulation, 1 layer 5/8” gypsum board each side STC 46 2x4 stud wall, RC-1 channel, 3.5”insulation, 1 layer 5/8” gypsum board each side STC 36 2x4 stud wall, 3.5”insulation, 1 layer 5/8” gypsum board each side © PAC International, Inc. — All Rights Reserved. THE RSIC-1 SOUND ISOLATION CLIP PAC International, Inc. Tel: (503) 649-7700 Fax: (503) 649-2710 www.pac-intl.com RSIC-1 STEEL WALL ASSEMBLIES 1 & 2 HOUR: STC 63 3-5/8” steel stud wall, RSIC-1, Drywall furring channel, R-19 insulation, 2 layers 5/8” borad RSIC-1 side, 3 layers other side 5/8” board UL U419, U423 STC 62 3-5/8” steel stud wall, RSIC-1, Drywall furring channel, R-19 insulation, 2 layers 5/8” board each side UL U419, U423 STC 60 3-5/8” steel stud wall, RSIC-1, Drywall furring channel, R-19 insulation, 1 layer 5/8” board RSIC side, 2 layers 5/8” gypsum board other side UL U419, U423 STC 56 3-5/8” steel stud wall, RSIC-1, Drywall furring channel, R-19 insulation, 1 layer 5/8” board each side UL U419, U423 GENERIC STEEL WALL SYSTEMS: STC 59 3-5/8” double steel stud wall, R-11 insulation, 2 layers 5/8” gypsum board each side STC 56 3-5/8” double steel stud wall, R-11 insulation, 1 layer1 5/8” gypsum each side STC 51 3-5/8” steel stud wall, R-11 insulation, 2 layers 5/8” gypsum each side STC 46 3-5/8” steel stud wall, R-11 insulation, 1 layer1 5/8” gypsum each side © PAC International, Inc. — All Rights Reserved. THE RSIC-1 SOUND ISOLATION CLIP PAC International, Inc. Tel: (503) 649-7700 Fax: (503) 649-2710 www.pac-intl.com RSIC-1 WOOD FLOOR CEILING ASSEMBLIES 1 & 2 HOUR: UL L528, L542, L532, L523, L514, L513 Carpet STC 61 IIC 74 Hard Wood STC 61 IIC 55 Tile STC 61 IIC 53 UL L547 , L518 Carpet STC 61 IIC 74 Hard Wood STC 61 IIC 55 Tile STC 61 IIC 53 FIIC test with tile floor FIIC 63 RSIC-1 STEEL FLOOR CEILING ASSEMBLIES 1 & 2 HOUR: UL L518 Carpet STC 60 IIC 70 Hard Wood STC 60 IIC 53 Tile STC 60 IIC 50 RSIC-1 CONCRETE FLOOR CEILING ASSEMBLIES 1 & 2 HOUR: UL L945 Carpet STC 60 FIIC 84 Hard Wood STC 60 FIIC 74 Tile STC 60 FIIC 70 Bare STC 60 FIIC 51 © PAC International, Inc. — All Rights Reserved. THE RSIC-1 SOUND ISOLATION CLIP PAC International, Inc. Tel: (503) 649-7700 Fax: (503) 649-2710 www.pac-intl.com Furring Channel: Minimum requirements:25 gauge (0.0188 inch thickness), Hemmed Edge Detail required on all 25 gauge Furring Channel. Meets or exceeds SSMA min. requirements. Optional:22 gauge (0.027 inch thickness) or 20 gauge (0.033 inch thickness) Depth:7/8 inch or 1-1/2 inch. Width Bottom:2-1/2 inches wide minimum. Width Top:1-1/4 inch wide Resilient Sound Isolation Clip (RSIC-1): Spacing Maximum 48 inches on center. Splice furring channel (hat track) with 6 inch over lap in mid span, secure with wire tie or with screws. Maximum allowable dead load 36 pounds per RSIC-1. Fasteners: RSIC-1 to wood #8 x 2-1/2 inch (63mm) minimum length Coarse thread screw. (Recommended # 12 x 2-1/2 inch Hex Head) RSIC-1 to Steel #8 x 1-5/8 inch (41mm) minimum length Fine thread screw. (Recommended # 12 x 1-5/8 inch Hex Head) DO NOT fasten Resilient Sound Isolation Clips (RSIC-1) to framing members with nails. Use only approved screws. Drywall to furring channel (hat track): Single layer 1/2 inch (12mm) use 1-1/8 inch (28mm) Type "S" screw with bugle head. Single layer 5/8 inch (16mm) use 1-1/4 inch (32mm) Type "S" screw with bugle head. Second layer 1/2 inch (12mm) use 1-5/8 inch (41mm) Type "S" screw with bugle head. Second layer 5/8 inch (16mm) use 1-5/8 inch (41mm) Type "S" screw with bugle head. Average Labor Rates: RSIC-1:72 clips per man hour average Drywall Furring Channel:550Lfpermanhouraverage Labor rates provided to PAC International, Inc by an independent contracting firm. © PAC International, Inc. — All Rights Reserved. THE RSIC-1 SOUND ISOLATION CLIP PAC International, Inc. Tel: (503) 649-7700 Fax: (503) 649-2710 www.pac-intl.com Walls: One and Two layers of 5/8" Gypsum Resilient Sound Isolation Clip (RSIC-1) shall be 48 inches (1219mm) on center maximum. (Horizontal) Fasten the Resilient Sound Isolation Clip (RSIC-1) to the structure members with approved fasteners Ensure the internal metal Ferrell is tight to the framing member. Locate the first row of RSIC-1 clips within 2 inches (50mm) from the floor, and within 6 inches (150mm) from the Ceiling. Snap in the Drywall Furring Channel (hat track) into the RSIC-1 clip at right angles (perpendicular) to the framing members. Ceilings: One and Two layers of 5/8" Gypsum Resilient Sound Isolation Clip (RSIC-1) shall be a maximum of 48 inches (1219mm) on center. (Perpendicular to Joist/Truss) Fasten the Resilient Sound Isolation Clip (RSIC-1) to the structural members with approved fasteners. Ensure the internal metal Ferrell is tight to the framing member Locate the first row of RSIC-1 clips within 8 inches (200mm) of the wall at each end of a run. Drywall Furring Channels (Hat Track) shall be a maximum of 24 inches on center (Vertically) for one layer of gypsum and 16 inches on center for two layers of gypsum. For enhanced acoustical performance, increase the number of RSIC-1 isolators. Snap in the Drywall Furring Channel (hat track) into the RSIC-1 clip at right angles (perpendicular) to the framing members. General Information: Resilient Sound Isolation Clip (RSIC-1), Furring Channel (hat track) and Gypsum board shall not carry heavy loads such as cabinets or bookshelves. Resilient Sound Isolation Clip (RSIC-1) is typically only required on one side of an assembly. Splice Furring Channel (hat track) with 6 inch over lap in mid span, secure with wire tie or with framing screw (7/16”) Seal all potential air leaks with non-hardening Acoustical caulking to achieve best Field Sound Transmission Class (FSTC) and Field Impact Isolation Class (FIIC) ratings. Use fire rated sealant where required Fire Test Information Resilient Sound Isolation Clips (RSIC-1) are not to be arbitrarily added to fire related assemblies. Check our web page for the latest updates to the Fire testing approvals. WWW.PAC-INTL.COM Check UL Fire Resistance Directory File# R16638 Check UL's web pages. www.ul.com/database Contact U.L. (877) UL- HELPS © PAC International, Inc. — All Rights Reserved. THE RSIC-1 SOUND ISOLATION CLIP PAC International, Inc. Tel: (503) 649-7700 Fax: (503) 649-2710 www.pac-intl.com RSIC-1 Wall Systems WOOD STC 56 STC 60 STC 62 STC 63 STEEL STC 56 STC 60 STC 62 STC 63 CONCRETE STC 53 STC 60 RSIC-1 Floor/Ceiling Systems WOOD STC 57 IIC 63 STC 61 IIC 53 STC 60 IIC 74 STEEL STC 60 IIC 72 STC 60 IIC 50 STC 60 IIC 51 CONCRETE STC 60 IIC 72 STC 60 IIC 62 © PAC International, Inc. — All Rights Reserved.