Loading...
HomeMy WebLinkAboutFile Documents.105 W Hyman Ave.0108-2022-BRES (12) APPLICATION ACCEPTED DATE: 2022-09-27 PERMIT NUMBER: 0108-2022-BRES Field Plan Set Must Be Printed In Color �1�g CITY OF ASPEN 11 p PERMIT NO. 0108-2022-BRES COMMUNITY DEVELOPMENT DEPARTMENT 1`o1k;t OWNER ASPEN 105LLC ACITY OF SPEN BUILDING PERMIT COVERSHEET N44,0 ADDRESS 105W HYMAN AVE CITY OF ASPEN PARCEL ID 273512469017 These plans muus eKeept at the building site or inspection delays may occur.Construction PROPERTY INFORMATION EFERENCES FROM 2015 IRC shall conform to these plans.All CV/A=crawl space ventilation required,sec.R408.1 Access required,R408.4 changes shall be approved by EE=emergency escape required sec R310.1 EU=enclosed usable space under stairs shall be Gyp,sec R302.7 lifiliging official. ADDRESS: 105 W HYMAN AVE UNIT: G/D=garage/dwelling separation,sec R302.5 and R302.6 STC=Sound transmission class not less than 45 at dwelling separations,app PARCEL ID: 273512469017 LEGAL DESCRIPTION: EAGLES NEST K OWNER: ASPEN 105 LLC RV=roof and rafter ventilation required,R806.1 SEPARATE PERMITS ARE A=attic access 22"x 30",30"headroom above,R807.1 REQUIRED FOR ELECTRICAL, PERMIT CONTRACTOR: LANDMAN-GIACINTO CONSTRUCTION INC SA=smoke alarms installed to NFPA 72 requirements,sec R314 PLUMBING,MECHANICAL,OR CO=carbon monoxide detector per City Ordinance 41 series 2008 FIRE SPRINKLER WORK SG=safety glazing required,sec R308.4 GR=guardrails,36"min ht,4"max opening;req at 30"drop any point w/in 36" horizontally,sec R312 SMOKE ALARMS AND WFP=window fall protection-operable window<24"AFF&>72"above CARBON MONOXIDE grade:use opening control device listed to ASTM F2090,sec R312.2 DETECTORS REQUIRED DESCRIPTION OF WORK Convert 2 bedrooms on the entry level to a single bedroom and remodel adjacent bathroom,convert an entry HR=handrails 34"-38"ht,sec R311.7.8 SI=stairway illumination,sec R303.7 THROUGHOUT DWELLING level bedroom to a media room removing an exterior window and converting another window to a door, PD=protect against decay,sec R317 UNIT PER CITY OF ASPEN REFERENCES FROM 20151MC MUNICIPAL CODE 8.15 remodel two existing bathrooms and laundry closet on the Bedroom level. v=bathroom and balanced whole house mechanical ventilation req. Ordinance 40,2016 DE=clothes dryer exhaust,sec 504.Makeup air req'd if over 200 CFM AS=access and service space for maintenance req'd,sec 306 MA=make up air required if hood exhausts greater than 400 CFM,sec 505.2 ET=exhausts terminate 3'from prop line and openings,10'from intakes, IT should be known that this review shall 501.3.1 not relieve the applicant of their IT=intake openings 10'from lot line&contaminant sources(vents,streets), responsibility to Comply with the 401.4 City of the requirementsAspen OF BUILDING Multi-Family FIRE SPRINKLER REQUIRED? Yes D=fasten and seal all ductwork per603.9 re q yof REFERENCES FROM 2015 IFGC Municipal Code.Pursuant to DV=direct vent req'd,sec 303.3 Sec.26.104.050,any permit or approval CA=combustion air not taken from bedrooms,bathrooms or issued in error or otherwise not in storage sec 303.3 conformity with the requirements of this CLASS OF WORK Residential FIRE SPRINKLER TYPE NFPA 13 D OD=outdoor appliances must be listed for outdoor use,sec 303.6 Title,shall be void. permit REFERENCES FROM 2015 IECC Y y F=new or replacement glazing shall not exceed 0.28 U-Value,NFRC label or approval issued in reliance upon or required,Ordinance 40,2016 as a result of,a materially false L=75%of lamps in permanently installed lights must be high efficacy,sec statement or representation made in REQUIRED SPECIAL R404.1 the process of obtaining the permit or BUILDING TYPE IRC Two family SE=Continuous air barrier required;all exterior joints,cracks,and hole ( INSPECTIONS caulked,gasketed,sealed,table R402.4.1.1 development approval shall,likewise, REFERENCES FROM 2014 NEC be void.Any person having received a 1 EP=electric panel'happy space'30"x36"x78",not in storage,sec 110.2 void or voidable permit or approval shall not be relieved from having to CONSTRUCTION TYPE VB ENERGY CODE COMPLIANCE Prescriptive Table conditions comtions h all applicable terms and of this Title and the City shall not be estopped from fully enforcing same. WORK CHANGES BUILDING FIRE OCCUPANCY GROUP(IBC) R-3 FOOTPRINT? No SPRINKLERS REQUIRED CODE EDITIONS 2015 IRC TOTAL SPA SQ.FT. 55 R ,,,ENET)) 02/23/2023 I FORCOOt OMd''UANCE linzhid OTHER CODE EDITIONS TOTAL SNOWMELT SQ.FT. HISTORIC PROPERTY? %Ij TOTAL POOL SQ.FT. DESIGN NO. GA WP 3370 FIRE RATING'. 1HOUR FIRE SPRINKLER EXISTING? Ye°• STC RATING SG.nm21 SYSTEM THICKNESS: 9.16'[234 PM LOCATION: INTERIOR FRAMING TYPE: WOOD ST110(LOADBEARING) '..t114411 .' .1. 06m 16. .1. 1B' 16. } 06 m 16' .1.[4mt OWmmt i. [4U6mmt [4mt ASSEMBLY REQUIREMENTS: LAYERGYPSUM PANELS: sir'[1 sHEE0ROCKG GYPSUM PANEL(UL TYPE Scx) WOOD STUDS x4[8 5.9 urn x 8s DM]WOOD STUDS,is[406 MIA o.c. AIR SPACE: r[2s M.AIR SPACE WOOD STUDS 2.x4[38 x 89 DM]WOOD STUDS,16[406 Mr.O0.C. INSULATION rr(89 M.FIBERGLASS INSULATION GYPSUM PANELS: ONE LAYER NW[16.9 NM[SHEEFROCK®GYPSUM PANEL(UL ME SOX) GENERAL WALL NOTES: 1. REFER TO PPPLCASLE CODES REQUIREMENTS TO ENSURE COMPLIANCE PRIOR TO CONSTRUCTION. 2. FOR THE MOST UPTODATE DETAILS,INCLUDING CONSTRUCTION VMNTIONS,REFER TO THE PUBLISHED DESIGN. 3. WHERE DESIGN NO.INDICATES[PER%THE FIRE RATING IS BASED ON V90RATORY TEST DATA OF THE REFERENCED SIMILARLY CONSTRUCTED ASSEMBLIES. 4. STUD SIZES AND INSULATION THICKNESS ARE MINIMUM UNLESS OTHERWISE STATED IN THE PUBLISHED ASSEMBLY. 5. STUD MD FASTENER SPACINGS ARE MAXIMUM UNLESS OTHERWISE STATED N THE PUBLISHED ASSEMBLY. B. PANEL ORIENTATION SHALL BE AS SPECIFIED IN THE PUBLISHED DESIGN. 1. FIRDRATINGS ARE FROM BOTH SIDES UNLESS OTHERWISE STATED. B. FIRDRATINGS ARE MM..WITH ONE OR MORE OF THE FOLLOWING MODIFICATIONS INCREASE STUD OEM INCREASE STUD MATERIAL THICKNESS.DECREASE STUD SPACING.DECREASE FASTENER SPACING.INCREASE INSULATION THICKNESS UP TO CAVITY DEPTH. B. WHERE ACOUSTICAL PERFORMANCE IS PRONGED IN AN ESTIMATED RANGE,THE VALUES ARE BASED ON LABORATORY TEST DATA OF SIMILARLY CONSTRUCTED ASSEMBLIES, 10. SWNDRARNGS ARE MAINTAINED WITH ONE OR MORE OF THE FOLLOWING MODIFICATIONS INCREASE SND DEPTH, rilIEWEil `1MATERVIL THICKNESS,INCREAmnrwPACINGS NOTE SPACING,FIREWINDECREA E THICKNESBUP THCAVITY.INCR ASE STUDSPACMUSTCREASE FAS ENERRONSOF INC.RNG.,I nun,o. A"FE= o=MA=0, luisp luc c�c GA WP 3370 �`°� W-P-1-43 16/2023