FORUM PHI I Clarification Change Log ',rI l
Project Address:332 W Main,Unit 101A,Aspen,CO 81611(Permit#:0031-2023-BCOM) II
Date:December 13,2023 CITY OF
Our contractor alerted us that there was a discrepancy between the Civil and Architectural site elevations.During AASPEN
coordination efforts with our Civil Engineer it was discovered that the proposed ADA compliant walkway would be too
steep given the current site conditions.For the proposed walkway to be ADA compliant a sloped area needed to be
added to the covered porch and the proposed concrete walkway needed to be lengthened toward Main Street to maintain These building plans mu's eMcept at the
the maximum 5%slope at the accessible route.
site or inspection
APPLICATION ACCEPTED DATE: 2023-12-26 PERMIT NUMBER: 0120-2023-ECHO Change Log by Sheet: delays may occur.Construction
- C.01 I Grading and Drainage Plan Master Perm it#0031-2023-BOOM shall conform to these plans.All
- Revise FFE Arch.iso'-s site elevation changes shall be approved by
- Revise Covered Wood Porch FFE site elevation the building official.
Revise concrete landing site elevation at West side of porch
COMMUNITY DEVELOPMENT DEPARTMENT ,'', - Revise concrete step riser heights at West side of porch at proposed ADA compliant landing
Master Permit-0031-2023-BCOM 4`'0-41 - Revise wood step riser heights at Main Street side of covered wood porch SEPARATE PERMITS ARE
/
'/ Revise length of proposed concrete walkway to maintain ADA compliant 5%slope REQUIRED FOR ELECTRICAL,
BUILDING PERMIT COVERSHEET N �/ A-006IProposedSitePlanatGrade l PLUMBING,MECHANICAL,OR
Revise elevations at Covered Wood Porch Reviewed by Engineering FIRE SPRINKLER WORK
CITY OF ASPEN - Revise concrete landing site elevation at West side of porch
- Revise concrete step riser heights at West side of porch at proposed ADA compliant landing 01/05/2024 11:29:50 AM SMOKE ALARMS AND
- Revise wood step riser heights at Main Street side of covered wood porch "It should be known that this review shall not CARBON MONOXIDE
- Revise length of proposed concrete walkway to maintain ADA compliant 5%slope relieve the applicant of their responsibility to DETECTORS REQUIRED
PROPERTY INFORMATION comply with the requirements of the City of THROUGHOUT DWELLING
Aspen.The review and approval by the City is UNIT PER CITY OF ASPEN
ADDRESS', 332 W MAIN ST 101 UNIT offered only to assist the applicant's MUNICIPAL CODE 8.15
understanding of the applicable Engineering
PARCEL ID: 273512441012 LEGAL DESCRIPTION: 3RD&MAIN CONDO requirements."The issuance of a permit based
OWNER- QUAKING ASPEN HOLDINGS LLC on construction documents and other data shall It should be known that this review shall
PERMIT CONTRACTOR: Boulder Construction Services,LLC not prevent the City of Aspen from requiring the not relieve the applicant of their
correction of errors in the construction responsibility to comply with the
documents and other data. requirements of the City of Aspen
Municipal Code.Pursuant to
Sec.26.104.050,any permit or approval
issued in error or otherwise not in
DESCRIPTION OF WORK Clarification/coordination of site elevations between Architectural site plan and civil site plan conformity with e regaireof
this
Title,shall be voidd.Similarly,,a nts any permit
or approval issued in reliance upon or
as a result of,a materially false
statement or representation made in
the process of obtaining the permit or
development approval shall,likewise,
be void.Any person having received a
USE OF BUILDING Commercial FIRE SPRINKLER REQUIRED? NO void or voidable permit or approval
shall not be relieved from having to
comply with all applicable terms and
conditions of this Title and the City shall
CLASS OF WORK Commercial FIRE SPRINKLER TYPE not be estopped from fully enforcing
same.
REQUIRED SPECIAL SEE NOTES#1 PLANS
BUILDING TYPE(IRC) INSPECTIONS
CONSTRUCTION TYPE ENERGY CODL COMPUANCE
OCCUPANCY GROUP IIeC) P WORK CHANGES BUILDING No
FOOTPRINT?
CODE EDITIONS 2:: 1 IHC TOTAL SPA SQ.FT.
OTHER CODE EDITIONS TOTAL SNOWMELT SQ.FT.
HISTORIC PROPERTY? Yes TOTAL POOL SQ.FT.
FIRE SPRINKLER EXISTING? No
3
.C\k U
CITY OF ASPEN 12022 427 RIO GRANDE PLI ASPEN, CO 12i28too
t m 1.
Fj-Mee
/2
0
12/27lui/2023
ZONING