Loading...
HomeMy WebLinkAboutFile Documents.332 W Main St.0016-2024-BCHO (5) Field Plan Set Must Be Printed In Color 1►1 j41 % I SEE NOTES#1 PLANS CITY OF ASPEN CHANGE ORDER#2 - 0016-2024-BCHO 2 MASTER PERMIT-0031-2023-BCOM These plans muus emMreptatthe building site or inspection delays may occur.Construction shall conform to these plans.All changes shall be approved by the building official. Change Log by Sheet: - COMcheck APPLICATION ACCEPTED DATE: 2024-03-14 PERMIT NUMBER: 0016-2024-BCHO - Revised COMcheck to match revised lighting plans SEPARATE PERMITS ARE A-702 I Proposed Main Level RCP REQUIRED FOR ELECTRICAL, - Revised the light designation for the recessed can lights in Hall 102 PLUMBING,MECHANICAL,OR - Revised light fixture LT-103-03 in Front Room 103 from track lighting to a chandelier FIRE SPRINKLER WORK Revised the lighting in Side Room 107 from track lighting to recessed can lights f A-703 Proposed Upper Level RCP SMOKE ALARMS AND COMMUNITY DEVELOPMENT DEPARTMENT IQlp I p pp CARBON MONOXIDE �`'/ ` - Added recessed can lights in SE Office 202 1, ''/ - Revised the light designation for the recessed can lights in Breakroom 203 DETECTORS REQUIRED BUILDING PERMIT COVERSHEET �� - Added recessed can lights in NW Office205 THROUGHOUT DWELLING CITY OF ASPEN - Added one wall sconce in Storage 206 UNIT PER CITY OF ASPEN - A-8031 Lighting Cut Sheets MUNICIPAL CODE 8.15 - Revised the cut sheet and light bulb specification for fixture LT-103-03 - A-804 I Lighting Cut Sheets It should be known that this review shall PROPERTY INFORMATION - Omitted cut sheets for fixture LT-107-01 not relieve the applicant of their - A-807 I Lighting Cut Sheets responsibility to comply with the ADDRESS: 332 W MAIN ST 101 UNIT - Omitted cut sheets for fixture C-01 Can Light requirements of the City of Aspen Municipal Code.Pursuant to PARCEL ID: 273512441012 LEGAL DESCRIPTION: 3RD&MAIN CONDO Sec.26.104.050,any permit or approval OWNER: QUAKING ASPEN HOLDINGS LLC issued in error or otherwise not in PERMIT CONTRACTOR: Boulder Construction Services,LLC conformity with the requirements of this Title,shall be void.Similarly,any permit or approval issued in reliance upon or as a result of,a materially false statement or representation made in DESCRIPTION OF WORK Revision to original lighting layout and re-specification of certain light fixtures. the processlm t obtaining the permit or, development approval shall,likewise, be void.Any person having received a void or voidable permit or approval shall not be relieved from having to comply with all applicable terms and conditions of this Title and the City shall USE OF BUILDING Commercial FIRE SPRINKLER REQUIRED? No not be estopped from fully enforcing same. CLASS OF WORK Commercial FIRE SPRINKLER TYPE SEE NOTES#1 PLANS COMcheck Software Version COMcheckWeb Interior Lighting PASSES REQUIRED SPECIAL 100%of lamps in BUILDING TYPE(IRC) Interior Li htin Compliance Certificate Interior Lighting Compliance INSPECTIONS Lighting P Statement permanently installed light Compliance Statement:The proposed Interior lighting alteration project represented In this document Is consistent with the fixtures must be high efficacy building plans,specifications,and other calculations submitted with this permit application.The proposed interior lighting -IECC R404.1 systems have been designed to meet the 2021 IECC requirements in COMcheck Version COMcheckWeb and to comply with any CONSTRUCTION TYPE ENERGY CODE COMPLIANCE COMCheck UA Alternative Project information applicable mandatory requirement listed in the inspection Checklist. ) Mark Hardeman-Senior Project Manager 2024-02-29 Energy Code: 2021 IECC Name-Title BAinature Date Project Title: 332 W Main,Unit 1O1A-2024-02-19 WORK CHANGES BUILDING Project Type: Alteration OCCUPANCY GROUP(IBC) B No Permit No. 0031-2023-BCOM FOOTPRINT? Construction Site: Owner/Agent: Designer/Contractor: 332 W Main Street,Unit 101A Ryan Walterscheid Ryan Walterscheid Aspen,Colorado 81611 Quaking Aspen Holdings,LLC Forum Phi CODE EDITIONS TOTAL SPA SQ.FT. 210E Hyman Avee.,Suite 202 210 E Hyman Ave,Suite 202 Aspen,Colorado 81611 Aspen,Colorado 81611 970-274-9598 970-274-9598 rwalterscheid@forumphi.com rwalterscheid@forumphi.com Allowed Interior Lighting Power OTHER CODE EDITIONS TOTAL SNOWMELT SQ.FT. A B c D Area Category Floor Area Allowed Allowed (ft2) Watts/ft2 Watts 1-Office 2008 0.64 1285 HISTORIC PROPERTY? Y a TOTAL POOL SQ.FT. Total Allowed watts= lzas Proposed Interior Lighting Power A B C D E Fixture ID:Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture IC X D) Fixture Fixture Watt. FIRE SPRINKLER EXISTING? No Office12008 sa.ft.1 LED:LT-101-01:Mitchell Flushmount:Other: 1 1 8 8 LED:LT-103-01:Aubrey Chandelier:Other: 7 1 60 60 LED:LT-103-02:Kenyon Picture Light:Other: 2 1 11 11 LED:LT-103-03:Aubrey Chandelier:Other: 5 1 12 12 LED:LT-104-01:Mitchell Flushmount:Other: 3 1 26 26 LED:LT-105-01:Vanity Wall Mount:Other: 2 1 11 11 LED:LT-106-01:Closet Surface Mount Other: 1 1 5 5 LED:LT-109-01:Nyra 28 Chandelier:Other: 1 1 75 75 LED:LT-202-01:Brambling Ceiling Fan:Other: 1 1 16 16 LED:LT-205-01:Brambling Ceiling Fan:Other: 1 1 16 16 LED:LT-206-01:Seaport Wall Sconce:Other: 1 3 9 27 LED:LT-207-01:Vanity Wall Mount:Other: 3 1 16 16 LED:LT-302-01:Fandelier:Other: 3 2 24 48 LED:C-02:Downlight:Other: 1 27 9 243 Total Proposed Watts= 575 CITY OF ASPEN 12022 427 RIO GRANDE PL I ASPEN, CO 046t \ 3/2 1,2p2A 1000 DGr��yGn Project Title: 332WMain,Unit 101A-2024-02-19 ReR1 CElY ® D r,aDD" a Data filename: 6171,04 Data Title: 332W Main,Unit 101A-2024-02-19 Reo t(;: /9 8171ih0624 ASPEN BUILDING DEPARTMENT ASPEN BUILDING DEPARTMENT