SEE NOTES#1 PLANS CITY OF
ASPEN
CHANGE ORDER#2 - 0016-2024-BCHO
2 MASTER PERMIT-0031-2023-BCOM These plans muus emMreptatthe
building site or inspection
delays may occur.Construction
shall conform to these plans.All
changes shall be approved by
the building official.
Change Log by Sheet:
- COMcheck
APPLICATION ACCEPTED DATE: 2024-03-14 PERMIT NUMBER: 0016-2024-BCHO - Revised COMcheck to match revised lighting plans SEPARATE PERMITS ARE
A-702 I Proposed Main Level RCP REQUIRED FOR ELECTRICAL,
- Revised the light designation for the recessed can lights in Hall 102 PLUMBING,MECHANICAL,OR
- Revised light fixture LT-103-03 in Front Room 103 from track lighting to a chandelier FIRE SPRINKLER WORK
Revised the lighting in Side Room 107 from track lighting to recessed can lights
f A-703 Proposed Upper Level RCP SMOKE ALARMS AND
COMMUNITY DEVELOPMENT DEPARTMENT IQlp I p pp CARBON MONOXIDE
�`'/ ` - Added recessed can lights in SE Office 202
1, ''/ - Revised the light designation for the recessed can lights in Breakroom 203 DETECTORS REQUIRED
BUILDING PERMIT COVERSHEET �� - Added recessed can lights in NW Office205 THROUGHOUT DWELLING
CITY OF ASPEN - Added one wall sconce in Storage 206 UNIT PER CITY OF ASPEN
- A-8031 Lighting Cut Sheets MUNICIPAL CODE 8.15
- Revised the cut sheet and light bulb specification for fixture LT-103-03
- A-804 I Lighting Cut Sheets It should be known that this review shall
PROPERTY INFORMATION - Omitted cut sheets for fixture LT-107-01 not relieve the applicant of their
- A-807 I Lighting Cut Sheets responsibility to comply with the
ADDRESS: 332 W MAIN ST 101 UNIT - Omitted cut sheets for fixture C-01 Can Light requirements of the City of Aspen
Municipal Code.Pursuant to
PARCEL ID: 273512441012 LEGAL DESCRIPTION: 3RD&MAIN CONDO Sec.26.104.050,any permit or approval
OWNER: QUAKING ASPEN HOLDINGS LLC issued in error or otherwise not in
PERMIT CONTRACTOR: Boulder Construction Services,LLC conformity with the requirements of this
Title,shall be void.Similarly,any permit
or approval issued in reliance upon or
as a result of,a materially false
statement or representation made in
DESCRIPTION OF WORK Revision to original lighting layout and re-specification of certain light fixtures. the processlm t obtaining the permit or,
development approval shall,likewise,
be void.Any person having received a
void or voidable permit or approval
shall not be relieved from having to
comply with all applicable terms and
conditions of this Title and the City shall
USE OF BUILDING Commercial FIRE SPRINKLER REQUIRED? No not be estopped from fully enforcing
same.
CLASS OF WORK Commercial FIRE SPRINKLER TYPE SEE NOTES#1 PLANS
COMcheck Software Version COMcheckWeb Interior Lighting PASSES
REQUIRED SPECIAL 100%of lamps in
BUILDING TYPE(IRC) Interior Li htin Compliance Certificate Interior Lighting Compliance
INSPECTIONS Lighting P Statement permanently installed light
Compliance Statement:The proposed Interior lighting alteration project represented In this document Is consistent with the fixtures must be high efficacy
building plans,specifications,and other calculations submitted with this permit application.The proposed interior lighting -IECC R404.1
systems have been designed to meet the 2021 IECC requirements in COMcheck Version COMcheckWeb and to comply with any
CONSTRUCTION TYPE ENERGY CODE COMPLIANCE COMCheck UA Alternative Project information applicable mandatory requirement listed in the inspection Checklist. )
Mark Hardeman-Senior Project Manager
2024-02-29
Energy Code: 2021 IECC Name-Title BAinature Date
Project Title: 332 W Main,Unit 1O1A-2024-02-19
WORK CHANGES BUILDING Project Type: Alteration
OCCUPANCY GROUP(IBC) B No Permit No. 0031-2023-BCOM
FOOTPRINT?
Construction Site: Owner/Agent: Designer/Contractor:
332 W Main Street,Unit 101A Ryan Walterscheid Ryan Walterscheid
Aspen,Colorado 81611 Quaking Aspen Holdings,LLC Forum Phi
CODE EDITIONS TOTAL SPA SQ.FT. 210E Hyman Avee.,Suite 202 210 E Hyman Ave,Suite 202
Aspen,Colorado 81611 Aspen,Colorado 81611
970-274-9598 970-274-9598
rwalterscheid@forumphi.com rwalterscheid@forumphi.com
Allowed Interior Lighting Power
OTHER CODE EDITIONS TOTAL SNOWMELT SQ.FT. A B c D
Area Category Floor Area Allowed Allowed
(ft2) Watts/ft2 Watts
1-Office 2008 0.64 1285
HISTORIC PROPERTY? Y a TOTAL POOL SQ.FT. Total Allowed watts= lzas
Proposed Interior Lighting Power
A B C D E
Fixture ID:Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture IC X D)
Fixture Fixture Watt.
FIRE SPRINKLER EXISTING? No
Office12008 sa.ft.1
LED:LT-101-01:Mitchell Flushmount:Other: 1 1 8 8
LED:LT-103-01:Aubrey Chandelier:Other: 7 1 60 60
LED:LT-103-02:Kenyon Picture Light:Other: 2 1 11 11
LED:LT-103-03:Aubrey Chandelier:Other: 5 1 12 12
LED:LT-104-01:Mitchell Flushmount:Other: 3 1 26 26
LED:LT-105-01:Vanity Wall Mount:Other: 2 1 11 11
LED:LT-106-01:Closet Surface Mount Other: 1 1 5 5
LED:LT-109-01:Nyra 28 Chandelier:Other: 1 1 75 75
LED:LT-202-01:Brambling Ceiling Fan:Other: 1 1 16 16
LED:LT-205-01:Brambling Ceiling Fan:Other: 1 1 16 16
LED:LT-206-01:Seaport Wall Sconce:Other: 1 3 9 27
LED:LT-207-01:Vanity Wall Mount:Other: 3 1 16 16
LED:LT-302-01:Fandelier:Other: 3 2 24 48
LED:C-02:Downlight:Other: 1 27 9 243
Total Proposed Watts= 575
CITY OF ASPEN 12022 427 RIO GRANDE PL I ASPEN, CO
046t
\ 3/2
1,2p2A
1000
DGr��yGn
Project Title: 332WMain,Unit 101A-2024-02-19 ReR1 CElY ® D r,aDD" a
Data filename: 6171,04 Data Title:
332W Main,Unit 101A-2024-02-19 Reo t(;: /9
8171ih0624
ASPEN
BUILDING DEPARTMENT ASPEN
BUILDING DEPARTMENT