File Documents.931 Gibson Ave.0037-2019-BRES (14)
IRRIGATION SCHEDULE IRRIGATION CONSTRUCTION NOTES SYMBOL MANUFACTURER MODEL NO. DESCRIPTION DETAIL NO. _ 1. DRAWINGS AND BASE INFORMATION-ALL BASE AND PLANTING INFORMATION HAVE BEEN PROVIDED BY LIFT STUDIO. THE CONTRACTOR 15 RESPONSIBLE TO NOTIFY HYDROSYSTEMS*KDI OF ANY DISCREPANCIES BETWEEN THE UTILITY OR PLANTING PLANS AND THE IRRIGATION PLAN.IF CONTRACTOR FAILS TO 1S12 SAM PRS WITH HE-VAN SERIES NOTIFY HYDROSYSTEMS*KDI AND MAKES CHANGES TO THE IRRIGATION SYSTEM DESIGN,HE ASSUMES ALL COSTS AND LIABILITIES ASSOCIATED WITH C.O■ RAIN BIRD HI-POP SPRAY HEAD 6 THOSE FIELD CHANGES. REFER TO SPECIFICATIONS FOR ADDITIONAL PROJECT REQUIREMENTS.CONTACT IRRIGATION CONSULTANT FOR CURRENT /j NOZZLE SPECIFICATIONS IF NOT PROVIDED. K p 1812 SAM-PRS WITH SST,CORNER Hydro 9 RAIN BIRD HI-POP SPRAY HEAD 8 NOZZLE 2. SYSTEM PRESSURE-CITY OF ASPEN FIRE PROTECTION DISTRICT HAS INDICATED THAT THE STATIC WATER PRESSURE IN THIS AREA SHOULD BE 80 PSI MIN AT "C.A,"4'A, HUNTER 1-20-06 WITH#NOZZLE GEAR DRIVEN ROTOR 9 THE CITY MAIN IN THE STREET.THE CONTRACTOR 15 RESPONSIBLE TO FIELD VERIFY PRESSURE PRIOR TO COMMENCING ANY CONSTRUCTION AND NOTIFY SYSTEMS HYDROSYSTEMS*KDI OF ANY VARIANCE FROM THE STATED PRESSURE IMMEDIATELY.WRITTEN DOCUMENTATION OF PRESSURE TEST AND RESULTS SHALL RAIN BIRD PEB-PRS-D ELECTRIC CONTROL VALVE -1 BE PROVIDED TO HYDROSYSTEMS*KDI AT CONSTRUCTION ONSET.IF CONTRACTOR FAILS TO FIELD VERIFY PRESSURE AND/OR NOTIFY Irrigation Consulting& HYDROSYSTEMS*KDI OR ANY VARIATIONS FROM THIS PRESSURE,THEN HE ASSUMES ALL CONSTRUCTION AND ENGINEERING COSTS ASSOCIATED WITH Water Management ✓ RAIN BIRD 44-LRC QUICK COUPLING VALVE 5 SYSTEM MODIFICATIONS REQUIRED TO ACCOMMODATE ACTUAL SITE PRESSURE.THIS SYSTEM HAS BEEN DESIGNED FOR A REQUIRED STATIC PRESSURE 860 Tabor Street,Suite 200 0 HUNTER I-CORE-M-42 STATION MODEL ELECTRIC CONTROLLER 2 OF 80 PSI MINIMUM AT THE POINT OF CONNECTION. Lakewood,Colorado 80401 o:303.980.5327 -W55-SEN WEATHER SENSOR DEVICE 3 3. IRRIGATION SYSTEM OPERATION INTENT-THIS IRRIGATION SYSTEM HAS BEEN DESIGNED TO IRRIGATE THE ESTABLISHED LANDSCAPE WITHIN A THREE NIGHT PER www.hydrosystemskdi.com HUNTER SOLAR SYNC 0 WEEK,SIX HOUR PER NIGHT WATERING WINDOW. ESTABLISHMENT WATERING WILL REQUIRE UP TO TWICE AS MUCH IRRIGATION FOR A FOUR TO SIX WEEK tit HUNTER SOIL-CLIK SOIL MOISTURE SENSOR 22 PERIOD. THE DESIGN 15 BASED ON THE FOLLOWING PROJECTED WEEKLY APPLICATION RATES AFTER ESTABLISHMENT. THESE FIGURES ARE BASED ON A 30-YEAR AVERAGE WEATHER DATA AND WILL NEED TO BE ADJUSTED DUE TO SEASONAL CHANGES AND WEATHER CONDITIONS ABOVE AND BELOW THE FEBCO 560U RP BACKFLOW PREVENTER 1 AVERAGE VALUES UTILIZED. —• FESCUE TURF 1.51"PER WEEK PEAK SEASON 1144*/ N/ OLDCASTLE/CARSON REFER TO SPECIFICATIONS AND DETAILS VALVE BOXES VARIOUS ORNAMENTAL PLANTINGS 0.78"PER WEEK PEAK SEASON _ NATIVE SEED MIXES 0.65"PER WEEK PEAK SEASON N/5 MACDONALD AY 1/4 TURN-1" MANUAL DRAIN VALVE 6 — - 4. EQUIPMENT INSTALLATION-ALL IRRIGATION EQUIPMENT MUST BE INSTALLED WITHIN PROPERTY LIMITS AND WITHIN LANDSCAPED AREAS. ANY EQUIPMENT LINE SIZE-23Y AND SMALLER GATE VALVE 4 OTHER THAN VALVE BOXES OR SLEEVING THAT CONTAINS PIPE OR WIRES SHOWN OUTSIDE OF THESE LIMITS 15 SHOWN IN THAT LOCATION FOR GRAPHICAL CLARITY ONLY.ALL VALVE BOXES SHALL BE INSTALLED A MINIMUM OF 2'-0"FROM EDGE OF ANY PAVED SURFACES UNLESS SPECIFICALLY INDICATED ON O RAIN BIRD PESB-PRS-D MASTER CONTROL VALVE 1 PLANS.BOXES INSTALLED IN OPEN TURF AREAS SHALL BE KEPT TO EDGES AND STAKED FOR REVIEW IF ALONG HIGH TRAFFIC AREAS.ALL VALVE BOXES FS DATA INDUSTRIAL IR250B(1") FLOW SENSOR 1 SHALL BE PLACED A MINIMUM OF 3'-0"FROM THE CENTERLINE OF ANY DRAINAGE SCALE.ALL VALVE BOXES WITHIN PAVEMENT SHALL BE TIER 15 RATED 0 _ BOXES FOR HEAVY DUTY NON-DELIBERATE TRAFFIC.BOX LID COLOR SHALL MATCH ADJACENT MATERIALS,I.E.GREEN IN TURF,TAN IN WOOD MULCH, • SCHEDULE 40 PVC MAINLINE 10 GRAY IN STONE MULCH,PURPLE FOR RECLAIMED WATER SYSTEMS(IF REQUIRED).REFER TO LANDSCAPE PLANS FOR MATERIAL COLORS AND TYPES. ALL BOXES SHALL BE INSTALLED TO BE FLUSH WITH GRADE AND IN AN ORDERLY MANNER. TYPE K COPPER HARD COPPER PIPE 1 5. PIPING INSTALLATION-IRRIGATION PIPING SHALL MAINTAIN A MINIMUM DISTANCE FROM BUILDING FOUNDATIONS OF 5 FEET OR AS DESCRIBED IN SOILS #100 NSF POLY LATERAL 10 REPORT,WHICHEVER 15 GREATER.ALL IRRIGATION PIPING AND EMISSION DEVICES LOCATED ON TOP OF OR WITHIN BUILDING STRUCTURE SHALL CLASS 160 PVC SLEEVING 11 CONFORM TO WATERPROOFING CONSULTANT REQUIREMENTS.PIPE ROUTING MAY BE SHOWN WITHIN THESE DISTANCES FOR GRAPHICAL CLARITY ONLY. ® HUNTER ICZ-1O1-25 DRIP VALVE ASSEMBLY - 14 6. MANUAL DRAIN VALVES-CONTRACTOR TO INSTALL ONE MANUAL DRAIN VALVE ON PRESSURE SUPPLY LINE DIRECTLY DOWNSTREAM OF BACKFLOW D PREVENTER AND AT ALL LOW POINTS AND DEAD ENDS OF PRESSURE SUPPLY PIPING TO ENSURE COMPLETE DRAINAGE OF SYSTEM.CONTRACTOR SHALL "\ /" i TORO BLUE STRIPE POLY DRIP TUBING 3/q'MIN.WIDTH 11,12,13 6 14 BE RESPONSIBLE FOR DETERMINING THESE LOCATIONS IN-FIELD AND INSTALLATION LOCATIONS SHALL BE NOTED ON AS-BUILTS.FOR INTERIOR MOUNTED ® DRIP LINE BLOW-0UT STUB 12 _ BACKFLOW PREVENTER LOCATIONS.INSTALL ONE BOILER DRAIN VALVE DOWNSTREAM OF BACKFLOW PREVENTER. N/5 RAIN BIRD XERI-BUG DRIP EMITTERS 14 7. POP-UP SPRAY NOZZLES-CONTRACTOR TO INSTALL PLASTIC NOZZLES ON ALL POP-UP SPRAY HEADS.INSTALL 15 SERIES NOZZLES ON ALL HEADS SPACED O AT 12'TO 14'.INSTALL 12 SERIES NOZZLES ON ALL HEADS SPACED 10'TO 11'.INSTALL 10 SERIES NOZZLES ON ALL HEADS SPACED AT E'TO 9.INSTALLS U NETAFIM TLCV4-12 ROWS SPACED 12" SUBSURFACE DRIPLINE 16,114 15 SERIES NOZZLES ON ALL HEADS SPACED AT 6'TO T.INSTALL 5'NOZZLES ON ALL HEADS SPACED AT 5'.INSTALL SIDE STRIP NOZZLES ON ALL HEADS WITH Z AN"5"DESIGNATION AND RIGHT AND LEFT CORNER STRIP NOZZLES ON ALL HEADS WITH AN"L"OR"R"DESIGNATION.VARIABLE ARC NOZZLES SHOULD (� NETAFIM TLCV4-12 RINGS SPACED PER DETAIL SUBSURFACE DRIPLINE RING-TREE 21 BE UTILIZED ADJACENT TO CURVILINEAR SHRUB BEDS OR FOR ANY ANGLES THAT ARE NOT A STANDARD NOZZLE ANGLE.WHERE INDICATED,INSTALL LOW 5) FLOW SQ SERIES SQUARE NOZZLES AT SPACING SHOWN. Q 100#NSF SUBSURFACE HEADER PIPE-1"PVC 16Z — 8. DRIP IRRIGATION-REFER TO IRRIGATION DETAIL SHEET FOR DRIP EMITTER QUANTITIES AND DRIP TUBING FLOW AND PLACEMENT. D 0 0 ETAFIM LVCZ1O0-f5-HFHP OR LVCZ550100-I5-LF SUBSURFACE VALVE ASSEMBLY 14 O 9. UNLABELED PIPING-ALL UNLABELED LATERAL PIPING SHALL BE 1"MINIMUM UNLESS OTHERWISE NOTED. BUILDING PENETRATION-UP 19 LU 8* BUILDING PENETRATION-THROUGH 10. SLEEVING-ALL SLEEVING UNDER PAVED SURFACES SHOWN ON PLANS 15 BY CONTRACTOR UNLESS OTHERWISE NOTED. SLEEVING SHALL BE INSTALLED IN COQ THE SIZES AND QUANTITIES SHOW BELOW. INHERE ON PLANS OR BASED ON THE SCHEDULE BELO . WHERE SLEEVES ARE SHOWN,BUT NOT LABELED,FOLLOW THE W Z (T' BUILDING PENETRATION-DOWN SCHEDULE BELOW. ALL MAINLINE,CONTROL WIRES AND DRIP LINES UNDER PAVED SURFACES ARE TO BE INSTALLED IN SLEEVING.ALL MAINLINE SLEEVE 0 LOCATIONS TO INCLUDE A SEPARATE WIRE SLEEVE. — to MI NI=CO T555-10-SV(1") LOCKABLE BALL VALVE 20 SLEEVED PIPE SIZE/WIRE QUANTITY REQUIRED SLEEVE SIZE&(QUANTITY) 9 m 5/4"-14"PIPING 2"PVC(1) v 410 CONTROLLER 4 STATION NO. 1-25 CONTROL WIRES 2"PVC(1) m CONTROL VALVE SIZE 26-SO CONTROL WIRES 3"PVC(1) co � GA(control-r) NUMBER OF SPARE WIRES-2 CONTROL AND 1 SPARE 11. SPARE CONTROL WIRES-CONTRACTOR SHALL EXTEND THREE SPARE WIRES(ONE COMMON AND 2 CONTROL WIRES)FROM EACH CONTROLLER TO THE END `,M J WIRES TO INDICATED CONTROLLER-SEE CONSTRUCTION NOTES OF THE MAINLINE SERVING THAT CONTROLLER OR AS SHOWN ON THE PLANS. INSTALL SPARE WIRES IN 10"ROUND VALVE BOX WITH QUICK COUPLING TT VALVE. REFER TO SPECIFICATIONS FOR WIRE COLOR. SEE IRRIGATION SCHEDULE FOR ADDITIONAL INFORMATION. V J 12. ADJUSTMENT-CONTRACTOR SHALL FINE TUNE/ADJUST THE IRRIGATION SYSTEM TO REDUCE/AVOID OVERSPRAY ONTO HARD SURFACES BY ADJUSTING G // NOZZLE DIRECTION AND NOZZLE RADIUS. . IP " 13. PLANS AND SPECIFICATIONS-CONTRACTOR RESPONSIBLE TO ENSURE WORK CONFORMS TO PLANS AND SPECIFICATIONS.AT ONSET OF CONSTRUCTION, `+✓ VERIFY PLANS ARE CURRENT.WHERE REQUIRED BY CITY OR TOWN,CONTRACTOR SHALL CONSTRUCT ONLY OFF CITY OR TOWN STAMPED PLANS. `\A \\ REVISIONS TO CITY OR TOWN STAMPED PLANS SHALL CONFORM TO CITY OR TOWN FIELD CHANGE PROCEDURES AND DOCUMENTATION. \- / \ 14. WATER BUDGETS AND PROJECTIONS-HYDROSYSTEMS-KDI HAS BASED THE IRRIGATION DESIGN AND THE ASSOCIATED PROJECTED WATER USE UPON SUCH ®°tp , \ FACTORS AS CITY OR WATER DISTRICT IMPOSED REQUIREMENTS.PUBLISHED PLANT SPECIES WATER NEEDS,SELECTED IRRIGATION METHOD EFFICIENCIES e AS REPORTED BY INDEPENDENT TESTING FACILITIES,HISTORICAL WEATHER DATA FOR THE PROJECT LOCATION,AND PROPER MAINTENANCE ® PROCEDURES.HYDROSY5TEM5*KDI IS NOT RESPONSIBLE,AND ACCEPTS NO RESPONSIBILITY,FOR THE ACTUAL WATER USAGE VARIATION THAT 15 A Date Issuance I!a♦ '> >, RESULT OF FIELD MODIFICATIONS TO THE SYSTEM NOT MATCHING CONSTRUCTION DOCUMENTS,IMPROPER MAINTENANCE,WASTE DUE TO SYSTEM 2019-08-13 WELS REVIEW ''-•�' /44 � ���..,/bo, a DAMAGE OR VANDALISM,OR WEATHER CONDITIONS THAT DEVIATE FROM PUBLISHED SO YEAR HISTORICAL AVERAGES. 2019-08-30 PERMIT 111 . "V4 /' 1 0 O 13. ASPEN WATER EFFICIENT IRRIGATION DESIGNER STATEMENT- HAVE COMPLIED WITH THE CRITERIA OF THE WATER EFFICIENT LANDSCAPING STANDARDS AND e'!o • v` APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE IRRIGATION DESIGN PLAN. I1 O (7 � µ Q�, O ofJ ,�� ! 0 5' 10' PO 14. IRRIGATION WITHIN ROW-CONTRACTOR IS RESPONSIBLE TO ENSURE THAT ANY IRRIGATION WITHIN THE ROW AREA(BETWEEN STREET AND THE PROPERTY 1 LINE)15 TO BE ON SEPARATE CONTROL VALVES THAN THOSE WITHIN THE PROPERTY LINE. \ • 15. IRRIGATION AND EXISTING TREES-ALL IRRIGATION WORK PERFORMED WITHIN THE DRIP LINE OF EXISTING TREES REQUIRES HAND GRUBBING NO DEEPER THAN o.,,,,-„, J/; L 77 SIX INCHES(5")AND MUST BE AS FAR FROM TREE TRUNK AS PRACTICALLY POSSIBLE.DO NOT CUT ROOTS LARGER THAN FOUR INCHES(4")IN DIAMETER. �* tt \ NORTH SCALE:1"=10' ®� 1b4,„ DIRECTORY WIRE ,', / 1 POINT OF CONNECTION #1 — 1" CONDUIT '7 PEAK FLOW REQUIREMENT:10 GPM.REQUIRED STATIC PRESSURE:80 PSI MIN. `��� IRRIGATION NOTES I R 1.00 \\ EXTEND COPPER TOOVER <' TIE ONTO COPPER STUB WITH ISOLATION VALVE DOWNSTREAM OF WATER METER AND BUILDING \ Title STRUCTURE PLANTING ON BACKFLOW DEVICE IN THIS APPROXIMATE LOCATION,BY OTHERS,RE:PLUMBING.EXTEND 1"TYPE K Know what's below. IRRIGATION SCHEDULE I R 1.00 SOFT COPPER TO BACKFLOW PREVENTER LOCATION.INSTALL ONE 1"REDUCED PRESSURE BACKFLOYV Call beforeyou dig. IRRIGATION PLANS I R 2.00 LEVELS ONE AND TWO. PREVENTER WITH AIR GAP PLUMBED TO DRAIN PER MANUFACTURER'S RECOMMENDATIONS,ONE BOILER oCALL 3 o,oeBUSINESSonnxovsirvnoonrvcessvoasvor IRRIGATION 4 DRAIN VALVE,ONE 1"FLOW SENSOR,ONE 1"MASTER VALVE,ONE ISOLATION VALVE AND EXTEND 1" CA30 ' dr 1" \ `� COPPER LATERAL TO BUILDING EXTERIOR.TEE OFF PRIOR TO EXITING BUILDING AND INSTALL TWO oic urvoaecsourvomeMssau ulnas. or IRRIGATION DETAILS I R 3.00 — IRS.00 VALVES SUSPENDED FOR ROOFTOP PLANTINGS AS SHOWN.COORDINATE WITH PLUMBING CONTRACTOR COVER TO EXTEND COPPER SUPPLY LINES TO ROOFTOP PLANTINGS.EXTEND ONE PEEP SHIELDED CABLE IRRIGATION CHARTS IRS.00 FROM FLOW SENSOR TO DATA RETRIEVAL UNIT LOCATED IN ASSOCIATED CONTROLLER.EXTEND 4 UFUL14#WIRE(TWO ORANGE AND TWO BLUE)AND CONNECT 2 OF THE WIRES FROM THE MASTER VALVE TO THE DATA RETRIEVAL BOARD IN ASSOCIATED CONTROLLER.SEE DETAIL SHEET FOR REQUIRED PIPE Section 5.1.7 requires LENGTHS UPSTREAM AND DOWNSTREAM OF FLOW SENSING UNIT.WORK SHALL CONFORM TO LOCAL Drawing No. moisture sensors for CODE.FEES AND PERMITS ASSOCIATED WITH WORK ARE TO BE OBTAINED AND PAID FOR BY all irrigated green CONTRACTOR.FINAL BACKFLOW PREVENTER LOCATION SHALL BE APPROVED BY OWNER PRIOR TO I R 1 roofs.Please include INSTALLATION. the graphic symbols on plan RECEIVED 09/09/2019 ASPEN BUILDING DEPARTMENT A II 11 CONTROLLER LOCATION A WALL MOUNT ONE CONTROLLER(REFER TO SCHEDULE FOR MODEL 4 STATION Hydro k COUNT),AT INDICATED LOCATION.120 VOLT POWER 15 AVAILABLE WITHIN 40 LF.OF D ( CONTROLLER LOCATION FROM RESIDENTIAL POWER.ELECTRICAL METER, SYSTEMS E M c WIRE/CONDUIT,STEP-DOWN TRANSFORMER(IF REQUIRED)AND POWER CONNECTION 7 7 7 TO CONTROLLER IS BY CONTRACTOR WITH WORK CONFORMING TO LOCAL CODES. Irrigation Consulting& EXTEND PESF SHIELDED CABLE FROM THE FLOW SENSOR AND 4 414 UFUL WIRES Water Management (TWO BLUE AND TWO ORANGE)FROM MASTER VALVE TO ASSOCIATED 860 Tabor Street,Suite 200 D CONTROLLER.CONNECT WIRES TO THE APPROPRIATE SENSOR INPUT PORTS.FEES Lakewood,Colorado 80401 A22 AND PERMITS ASSOCIATED WITH WORK ARE TO BE OBTAINED AND PAID BY o:303.980.5327 CONTRACTOR.FINAL CONTROLLER LOCATION SHALL BE APPROVED BY OWNER www.hydrosystemskdi.com S PRIOR TO INSTALLATION.MOUNT ONE WEATHER SENSOR ON BUILDING WHERE THERE I' * A21 15 20 FT.OF CLEARANCE FROM ANY OVERHANG OR OBSTRUCTING FEATURE.FINAL WEATHER SENSOR LOCATION SHALL BE APPROVED BY OWNER PRIOR TO dr 1" A20 INSTALLATION. t` 10 1/ A19 ► \v .�P , dr 1" A18 ,25 ,—__ 25 V. l*, dr 1" A VAL4441%, ll a� 25 ''-r, • dr 1" AriEl ' ' -',-, 1-1/2" * - 4lAW .,• 411A1). . 4'6'7 A15 10 1" — . .00, •Ar, olv:'n12. '...1'' , — _; iltrii ' * - .• '',*-'',- - #10. ..,,,,,,,b,! ..... 10 1 y, �2s �R `� 10 1"® D '''',-\ __.* .4 X 7 „ ' 4,* iit,441,,,, 41E0 M ‘(T) 1 \ �.-7y 4 // ✓ ram. \�—�. _ ✓ �,,, A/ .� Q A25 /�v I / .� O� �`�, l Z 7 I /)__,,,, ,//_it: .----- --...44,........,,,,..;...„................: _ 111 / �Jr \\� it/" CA \\—�/1 /�� . �.1� I m o �_ I / -/ �EVEL 1:LOCATE COPPER STUBS t ��� ,1.� �* - cn m iiiiiitt., ���FROM MEGHANIGAL ROOM VALVE .5" _ //� 'LOCATIONS.CONNECT,CONVERT TO � ` y CO- /• / -, POLY HEADER AND DRIP TO '0 ,J dr 1" / / PLANTINGS.A50 SERVES LEVEL 1 !a k I • U PLANTING. ® �.,, .. �� / n \ \ I 1 `�j �.�� t=" LEVEL 2 LOCATE COPPER STUBS 1-1 2 \ �` v v A .� N/V -- .�FROM MECHANICAL ROOM VALVE /� — — \ X — ,✓i •44, LOCATIONS.CONNECT,CONVERT TO 7)7 ' _AiG � �-POLY HEADER AND EXTEND DRIP TO -'Alb''\ 'PLANTINGS.EXTEND MOISTURE �- ill. _ 1 :- I" r. o 'i� SENSOR WIRE IN CONDUIT TO f / __ .. • •�\�/ �� %" CONTROLLER LOCATION.A 51 „J- •// / \ `s� VAS �y ,' /SERVES LEVEL 2 PLANTING. le A' _ ,T+1 .� A10 dr 17,:er,...7.,,.. 4 ,,: Date Issuance ---7 --..,„ ��� � �Q ��� 2019-08-13 WELS REVIEW '� / "-\ ' 2019-08-30 PERMIT AW Z . ! 4 AS 1 , -- '--='' „ --— Ey.' — ,,7•Nirir MIFF 0 LOCATE COPPER STUB AND WIRE CONDUIT FROM "-',\�• ���/ -41/ � I t r' / MECHANICAL ROOM.CONNECT,INSTALL ONE LOCKABLE I •► • -`v' - •. -»� �� o _ DIRECTORY BALL VALVE,CONVERT TO PVC MAINLINE AND EXTEND AS v i \ �•�;_:� N. r*Lrj, i v SHOWN.EXTEND VALVE WIRES FOR GREEN ROOF VALVES V \t ',> �> �' IN CONDUIT BACK TO VALVE LOCATIONS WITHIN // ,_—- ' t k�.'�:� /`-, �\�\ �l ♦`* IRRIGATION NOTES IR1.00 MECHANICAL ROOM. �' y� - IRRIGATION SCHEDULE IR1.00 ,' ' Mb "" 'doge IRRIGATION PLANS IR2.00 \ A2 4 �` ,/ IRRIGATION DETAILS IR3.00 IR5.00 d1 1" � • � IRRIGATION CHARTS IR5.00 Title Q® / OD 0 5' 20 IRRIGATION r � :MM77 PLAN Orb: j 1, I 811 T /I° NORTH SCALE:1"=10' Know what's below. Drawing No. loEal�bo°oMIZERtl;9mas of I R2 .00 RECEIVED 09/09/2019 ASPEN BUILDING DEPARTMENT BUILDING EXTERIOR DIRECTORY TYPE"K"RIGID COPPER-CONNECT TO BUILDING GOLD WATER SERVICE LINE DOWNSTREAM OF 500'MAX WATER METER,UPSTREAM OF ANY PRESSURE ...... IRRIGATION NOTES I R 1.00 REDUCING VALVES OR OTHER BUILDING SERVICE EQUIPMENT II.-:o ;' SIDE V,�., IRRIGATION SCHEDULE I R 1.00 81' FEB W GO 86 REDUCED PRESSURE BAGKFLOW ° PREVENTER WITH INTEGRAL UNIONS \' ip% CAM ADAPTER-LINE DIA.(FOUR REGD.) I IRRIGATION PLANS I R 2•00 PRESSURE REDUCING VALVE(A5 REQUIRED,REPLAN) cuUa wess oars IN AOvarvc /' CxC F TEE IRE CONDUIT FROM CONTROLLER WIRELESS WIRELESS ' - ' / Know what's below. 111 IRRIGATION DETAILS IR3.00 IR5.00 Call before you di. K SOLAR-SYNC SOLAR-SYNC DIG UrvE,OREXAVATEFORHEMAR. OF H d ro ID RECEIVER MOUNTED SENSOR IRRIGATION CHARTS IR5.00 YsysTEMs L I- ON BUILDING SENSOR DON C (RE:FLANS),WIRES BUILDING _ E ■IIII �L E EXTEND TO EAVES —/ —U•,0'1iII 17 CONTROLLER (RE:PLANS) SECURE CONTROLLERNNCHORBOL Irrigation Consulting& . • IIl'.'_�,_.in.11111 ,IIII��IIIIIIII mooliSiili IIII�,IIIIIIIIIIm "IIIIIII� INPUTS WALL WITH ANCHOR BOLTS II I II III SOLAR SYNC SENSOR-TOP OF Water Management � 0• 0• 0• FRONT VIEW IIIII ' p II I l SENSOR TO BE ABOVE GUTTER 860 Tabor Street,Suite 200 �I EMT APAPTER NV WASHER 4 LOCK AND/OR ANY OBSTRUCTIONS Lakewood,Colorado 80401 RING FLOW LINE SIZE MASTER VALVE UI EMT CONDUIT-SIZE TO o:Y ro ystemsk V FLOW SENSOR 1 � ACCOMMODATE CONTROL WIRE www.h dros stemskdi.com ■ '-:L .: QUANTITY I ADJUSTABLE LENGTH BALL VALVE FOR SHUT-OFF I EMT CONDUIT r•L S TE MOUNTING ARM TYPE K HARD COPPER TO PENETRATION LOCATIONS , TO VALVE 4 SO"MAX. /Q"i SENSOR 11_1 -6.' '112"MIN. 3/4"I.P.MALE BRASS BOILER DRAIN LOCATIONS �i'i®TJ�4/'I W/WHEEL HANDLEFEBGO 601 AIR GAP DRAIN54"MIN. POWER SUPPLY TOSECURE BRACKET TO EAVE PER 60"MAX. 120V GFCI OUTLET FINISH FLOOR 2"TYPE"L"RIGID COPPER TUBINGMANUFACTURERS RECOMMENDATIONS. rilliMilir FASTEN TUBING TO FINISH FLOOR a 1S"O.G. BUILDING EAVE VENT BACKFLOIN PREVENTER DRAIN INTO 1y FLOOR DRAIN %• i FINISH FLOOR •It�� FINISH FLOOR NOTE:MOUNT SENSOR RECEIVER PER A .e�Allillt IIIIIIIII-IIIII IIIII IIIIIJIIII CONTROLLER DETAIL. SECURE BACKFLOIN PREVENTER ASSEMBLY AND CONEL AND COPPERPP T AS LE VIAER UAT 6 FTT REFER TO ELECTRICAL PLANS FOR LOCATION OF POKIER SOURCE CHANNEL FASTENERS AT 6 FT.O.G. FOR IRRIGATION CONTROLLER IN EACH LOCATION, POINT OF CONNECTION LJJ co. ELECTRIC CONTROLLER, TYPICAL WEATHER SENSOR 111 SAVE MOUNTED-SolarSync © z 10.ROUND VALVE BOX-BRAND THE W LETTER"D'IN LID.REFER TO 10"ROUND VALVE BOX BRAND TECHNICAL SPECIFICATIONS. 0 10"ROUND VALVE BOX.BRAND"GV" "GG"INTO VALVE BOX LID. 2"VALVE MARKER PVC LATERAL-45 ELL TO C) ON LID OF VALVE BOX.REFER TO REFER TO TECHNICAL SPECIFIED TECHNICAL SPECIFICATIONS. SPEGIFICATONS, SCH.40 PVDC REDUCING LU Z "CRUSHED GRAVEL SUMP 1 CU.FT. _ MALE ADAPrER a d_ FINISH GRADE .M°4 m .I.,. IS'Al _ _ ) FINISH GRAPE —I =I I J 1' I Am'WI _ IS'Al -FINISH GRADE RECTANGULAR VALVE BOX.GRAND LID (n I—IIII= IIIIIII B TO TECHNIC,SPECIFICATIONS.CENWITH CONTROLLER 4 STATION A TER �f Q IIII- IIII I 1 L IIII I11//q BOX OVER ASSEMBLY. FBOTTOM OF QCVINID'OF — I IIII IIII I IIII IIIII _ 3" = I III 4 1 GL 60 PVG ACCESS SLEEVE- 41 12' Z 2 _ II VIDE GATE VALVE W/GROSS HANDLE AND LENGTH AS REQUIRED IIII_ WIRING WRHIISH GRADE O W SOLID WEDGE DISC. 1"BRA55 NIPPLE LENGTHI REQUIRED ZH_ 1 /"CRUSHED GRAVEL SUMP- IIII2 I WC ACCESS SLEEVEOCRUSHED GRAVEL wMP-FILLQUICKCQUPLINGVALVE ` 5/��FxF SCH,80 PVG 90 ELL(2) PVC B L VGE 9PPRE GONTROVGOMMONt/JWT BOX TO WITHIN 2"OF TOP OF 6" N VALVE BOX �•/�.-- i } I 0 ALVE-FIPTxFIPTW Z"xCL PVG NIPPLE SCH.BO(2) OS'CLASS 160 PVC SLEEVE BOTTOM TO /"XS'NSA.a0 GALVANIZED STEEL NIPPLEELECTRIC CONTROL VALVE CD BE NOTCHED ANp CONTACT TOP OFLINE SIZE BRA55 CQUPLIN a'•BRAY GLOBE VALVE ` PRESSIURE MAINLINEy,x12"REBAR STABILIZINTAKE © ''/n"CRUSHED GRAVEL SUMP-FILLBOx1 ° SCH.4O PVG MALE ADAPTER(2)-SIZECOUPE NTYPICAL6 OP.LSVELOGATIDES PER GK SG BOTTOM80 PVC NIPPLE LENS AS M O �' TO EQUAL GATE VALVE DIAMETER %"MxF SLH.40 PVC.90 ELL e M MAR REQUIRED O) �� 0I■ - PVC PRESSURE MAINLINE -IOUINTO NG W/613RA551 N9ERTZSmTAB11LIZER •I,oS. ON '°v SERVICE TEE-SOLVENT VELD J+/ SOIL BLANKET COVERING SUMP OR GASKETED FITTING-REFER co ELBOW,PROVIDE WITH 1"MIPT INLET / O° TO SPECIFICATIONS :1 ,I II III r� °"-�N."x4"PVC NIPPLE SCH.60 1�1 , PRESSURE MAINLINExi"PVC SERVICE TEE- CONTROL WIRE BUNDLE � SOLVENT MELD OR GASKETED FITTING REFER a"CRUSHED GRAVEL SUMP,SEE TO SPEGIFICAIONS TECHNICAL SPECIFICATIONS FOR NOTE:DIAMETERS OF BALL VALVES,PVC FITTINGS AND NIPPLES SHALL IIIIII 7 UNDISTURBED 501E SUMP SIZE EQUAL ELECTRIC CONTROL VALVE DIAMETER.VALVE BOXES SHALL BE PVC PRESSURE MAINLINE INSTALLED PARALLEL OR PERPENDICULAR TO ADJACENT SIDEWALKS AND HARD SURFACES INHERET APPLICABLE.APPLY TEFLON TAPE TO ALL MALE APPLY TEFLON TAPE TO ALL THREADED NIPPLES APPLY TEFLON TAPE TO ALL MALE THREADED THREADED FITTINGS AND THREADED NIPPLES. PVC,FITTINGS AND ALL NIPPLES GATE VALVE 4 QUICK COUPLING VALVE MANUAL DRAIN VALVE 6 ELECTRIC CONTROL VALVE O 24V-PVC Lateral I I Date Issuance I I 2019-08-13 WELS REVIEW I I 2019-08-30 PERMIT SET BOTTOM OF CAP AT GRADE SET LIP AT FINISHED GRADE II I CURB AND GUTTER,SIDEWALK OR HARD 5" SURFACE WHERE APPLICABLE CURB AND 6V I I LK,SIDEWALK OR PAVED SURFACE IMi HARD SURFACE WHERE APPLICABLE NOTE:REFER TO TECHNICAL CURB AND GUTTER IIIII I—III 61 SPECIFICATIONS FOR MINIMUM (IF APPLICABLE) III IIII .,,/ TRENCH WIDTHS. �, ,,,/ —111 — af' i'..iq/ i'.,IFP GRADE * 561 MIN. _ FINISH IIII IIII= -III—II —III ,2"MIN III _III IIII II I I II III II I I I I I I=I I—III I I 17 12"HI-POP SPRAY HEAD III-III- ROUGH GRADE =I I I I I I I I IIII—IIII =I 4-E,BODIES:14' I I I I= -III I= I I=III—I H—III I III IIII IIII IIII 4 BODIES:18"IIII- III III III PIPE SLEEVE MARKER- 121 BODIES:18' — 2"PVC INSTALL AT BOTH ENDS OF EACH 11E11GEAR DRIVEN ROTOR 12"BODIES:24" -III-III-IIII SLEEVE LOCATON AND EXTEND AT IIII IIII LEAST 5''ABOVE GRADE.SPRAY EXPOSED PORTION OF MARKER WITH 24'MIN. GREEN FLUORESCENT PANT.REMOVE Y,"MALExBARB 90E ELL 4 IIII ART FINAL INSTALL. Y"FLEX PIPE(6"-12"LENGTH) Y,"x%"BARBxMALE ELL Y,"MALExBARB ADAPTER SPRAY HEAD LATERAL I 1$I VI DX POLY LATERAL PIPING W/INSERTx O. ,"DIA.POLYETHYLENE SWING PIPE PIPING OR DRIP LINE -III , u FIPT FITTING HEADER. FI B (4 L.F.MAXIMUM LENGTH) -III— SEAL ENDS OF SLEEVE WITH TEl Ni'MALEXBAR6 ADAPTER ROTOR LATERAL , CLOTH DUCT TAPE(TYPICAL) ,f(�, PIPING Imo.! BACKFILL MATERIAL(TYP.) PVC SLEEVING TYPICAL) 1��i/'. _ MAINLINE NOTE: IRRIGATION POLYETHYLENE LATERAL PIPING FI _— — - CONTROL WIRE BUNDLE OR TWO • ALL SLEEVE MATERIAL PER IRRIGATION SCHEDULE,SIZE AS NOTED ON WITH INSERTAPIPT FITTING AND WIRE LOMMUNICATON CABLE(PER DETAILS NOTE: -III=III=I I= PLAN. • SET HEAD PERPENDICULAR TO FINISH GRADE SWING. STAINLESS STEEL CLAMPS SPECIFICATIONS) • INSTALL SLEEVES IN SIDE-BY-SIDE CONFIGURATION INHERE MULTIPLE • FLEX PIPE SHALL BE ATTACHED TO BOTTOM SPRAY HEAD SLEEVES ARE TO BE INSTALLED.SPACE SLEEVES 4"TO 6"APART,DO INLET ONLY. NOT STACK SLEEVES VERTICALLY. • APPLY TEFLON TAPE TO ALL MALE PVC THREADED SET HEAD PERPENDICULAR TO FINISH GRADE • CONTRACTOR TO COORDINATE WITH FLATWORK INSTALLER TO BRAND A FITTINGS AND NIPPLES. 'V1 IN SIDEWALK OR CURB AT BOTH ENDS OF SLEEVE CROSSING. • SLEEVING THROUGH OR UNDER RETAINING WALLS,PLANTER WALLS,POND LINING,OR PATER QUALITY AREAS SHALL BE COORDINATED WITH CIVIL Drawing No. WORK AT APPROXIMATE LOCATIONS SHOWN. HI-POP SPRAY HEAD 8 GEAR DRIVEN ROTOR �„\ T4RE N CH 10 IRRIGATION SLEEVING 4111 I R3.00 L RECEIVED 09/09/2019 ASPEN BUILDING DEPARTMENT PUN PLAN SECTION EEMITTER MATERIAL T°SCHEDULE TO FOR DIRECTORY EMITTER QUArvrrr REFER To PUNTING BAGRFILL MATERwL SPED F CATIONS FOR MANUFACTURER rFLUSH VALVE 12"POP-UP SPRAY HEAD WITH POLY l AND MODEL NUMBER. IRRIGATION � TEULE SWING PIPE(ZANE OPERATIONAL 1 O EMITTER RO'Nemb /MIN ((��] /— 6 IRRIGATION S IR1.00 Hydro ,�' INDICATOR HEAD INDICATOR) PUNT ROOTBALL _� / D PLANTER BED 10"ROUND VALVE BOX WIT"COVER " EM��STAKE TO EDGE of � , i f _ " - IRRIGATION PLANS I R 2.00 SYSTEMS WALL OR EDGER -BRAND"DB"INTO VALVE BOX LID. REFER TO TECHNICAL _ EMPTER MICRO TUBrvG-60 _ III yy SPECIFICATIONS. MAXIMUM LENGTH 1 Irrigation Consulting& ��00 _ �l�l —�POLYDRIPnBIrvG_RE IRRIGATION DETAILS IR3.00 - IRS.00 g g PUN DOWN QPE TECHNIC,SPECIFICATIONS Water Management FINISH GRADE = l 860 Tabor Street,Suite 200 , � i- -IIII GPROVED GAUGE J EGrAEQR IRRIGATION CHARTS IR5.00 V EMITTER EMITTER QTY.AT MULCHED EMITTER QTY.AT NATIVE SECTION APPROVED EQJPL Lakewood,Colorado 80401 DISTANCES VARY:CONTRACTOR SHALL —IIII INS PVCMIP BALL VALVE WITH. LPVC AM PLANT SIZE MOTIFS: O:303.980.6327 O LOCATE FLUSH VALVE BOX TO BE IL INSxMIPi ADAPTER AND 5.5.CLAMP FLOW RATE BED LOCATIONS SEED LOCATIONS INSTALL EMITTERS ON OPPOSING SIDES OF ROOTBALL.THREE OR MORE EMITTERS SCREENED BY PLANT MA RI 1-3 GALLON MATERIAL 0 AL AND . SHALL BE EQUALLY SPACED AROUND ROOT BALL. www.hydrosyste111skdi.com i—��- ACCESSIBLE.OPERATIONAL INDICATOR 5 bFH ONE EACH ONE EACH • EMITTERS ARE TO BE INSTALLED TO CLEAR SURFACE BY A MINIMUM OF t"AND A / ` SHALL BE LOCATED FOR EASY 5/a"DRIP TUBING-COIL SUFFICIENT 5 GALLON MATERIAL O.5 bPN TWO EACH TWO EACH MAXIMUM OF 2". I �I VISIBILITY DURING OPERATION 4 LENGTH •IN BOX TO EXTEND HGSE _ FLUSH ALL LINES THOROUGHLY INCLUDING EMITTER MICRO-TUBING PRIOR TO • IF PUNTING ON A OPE FROM 1.0 GFN FOUR EACH • EXHAUSTPHEADER Oo D O D WASHED RIVER OF VALVE SUMP�X �� E 11.0 GPH A GPH ES�H EIGHT EACH • N� EVE ZONES CARE DESIGNED TO BOTH EMITTERS ON UPHILL SIDE i (\` �— 15'CALIPER TREE TITER INSTALLATIONL OR STEEPER.INSTALL 1 POLY CU.FT.) 2"CALIPER TREE 25"CALIPER TREE 5. 51X EACH N EAGH OF ROOT BALL. IP ��� 'DM SELF-FLUSHING,PRE55U COMPENSATING-TYPE UNLESS _ .,1 OR DRIP LATERAL OM,OTHERWISE WITHIN TECHNICAL SPECIFICATIONS. ,___�4�TWIT®®®T�..IJJ///'PCCO'JNT FOR DIFFERENCES IN PUNT REQUIREMENTS HALL E ZONES)AND SUN ES ARE E. t DEFLECT TUBING TO PERMIT 3Yi'CALIPER TREE 1A GPH NINE EACH ELEVEN EACH • CONTRACTOR SHALL ENSURE HYDROZONES ARE VALVED SEPARATELY AS SHOWN ENTRY THROUGH BOTTOM OF ON Pam'a CALIPER TREE to GPH TEN EACH TWELVE EACH VALVE BOX. — • SITE S ES ONS MAY DICTATE THAT MULTIPLE SUN EXPOSURES ARE VALVED E.FT.CONIFEROUS TREE 1A GPH Fd1R EACH 51X EACH TOGETHER THER WRING THE DESIGN PROCESS.CONTRACTOR SHALL ADJUST EMITTER SCHEDULE AS FOLLONIs: INSERT TEE WITH CLAMPS a FT CONIFEROUS TREE to GPH SIX EACH NINE EACH •• EMITTER QUANTMES SHALL REMAIN THE SAME BUT EMITTER GALLONAGES SHALL BE DOUBLED FOR PLANTS WITH SOUTH AND WEST EXPOSURES. 10 FT.CONIFEROUS TREE 10 GPH EIGHT EACH TWELVE EACH •• EMITTER QUANTITIES AND GALLONAGE SHALL BE AS SHOWN IN SCHEDULE FOR PUN.NTH EA5T EXPOSURES. 12 FT.CONIFEROUS TREE 1.0 GPH TEN EACH FOURTEEN EACH •• PUNTINGS WITH NORTH NORTH°AND EAST EXPOSURE SHALL DICTATE VALVE RUN-TIMES AND CONTRACTOR SHALL KM,SCHEDULING ACCORDINGLY. DRIP FLUSH VALVE DRIP EMITTER CO WITH OPERATIONAL INDICATOR BELOW GRADE W D PLANT MATERIAL LINE FLUSHING VALVE AND 7 INDICATOR HEAD PLUMBED TO ` c0 EMITTER-REFER TO SCHEDULE FOR • PVC OR POLY-REFER TO DETAIL. EMITTER QUANTITY.REFER TO R. � � PLANTING BAGKFILL MATERIAL — SPECIFICATIONSMOL BER MANUFAGNRER "—•+'—• ';flflflI , U DRIPLINE START CONNECTION 0 WEED BARRIER FABRIC MALE ADAPTER POLY DRIP TUBING \/\�)� _ MULCH LAYER Z Uj PLANT ROOBALL \ CO _ �� -- FINISH GRADE d ^••,°'•_. 1', . _ PVC SCH.40 ELL ALL DRIE START CONTIONVALVE BOX-BRANDBOX LID1"L STAKEOR 12"POPSECTION APPROVED EQUAL — W z PLANT SIZE EMITTER EMITTER QTY.AT MULCHED EMITTER QTY.AT NATIVE G SLUNG PIPE(zoNE oPERATow ej WITH DISC FILTER AND PRv p NOTES: ■ INDICATOR) - - - - - (1) FLOW RATE BED LOCATIONS SEED LOCATIONS INSTALL EMITTERS ON OPPOSING SIDES OF BALL. BALL.THREE OR MORE EMITTERS DRIP VALVE ASSEMBLY(SEE m SHALL BE EQUALLY SPACED AROUND ROOT BALL. � 1-2 GALLON MATERIAL OS GPH ONE EACH ONE EACH {}• SCHEDULE) • EMITTERS ARE TO BE INSTALLED TO CLEAR SURFACE BY A MINIMUM OF 1"AND A ' (� 5 GALLON MATERIAL 0.5 GPO TWO EACH TWO EACH MAXIMUM OF 2". -l�l N •1 VALVE SIZE MIPNINS.PVC ADAPTER I AREA PERIMETER TO • FLUSH ALL LINES THOROUGHLY,INCLUDING EMITTER MICRO-TUBING PRIOR TO T I. ����.rII!i/ 0) STAINLESS STEEL WORM GEAR OR 1Y,"CALIPER TREE 1.0 GPH THREE EACH FOUR EACH EMITTER INSTALLATION. i-I.' ..�,I„=�'B`L- PINCH CLAMP DRIPLINE TUBING LATERAL m IF PLANTING ON A 4:1 SLOPE OR STEEPER,INSTALL BOTH EMITTERS ON UPHILL SIDE I� -1j`I__L1y IR 2"CALIPER TREE 1.0 GPH FOUR EACH SIX EACH • OF ROOT BALL. �� ` @ DY'CALIPER TREE 1.0 GPH SIX EACH EIGHT EACH • EMITTERS SHALL BE SELF-FLUSHING,PRESSURE COMPENSATING-TYPE UNLESS �,I �cgUOS$HOY° `,J NOTED OTHERWISE WITHIN TECHNICAL SPECIFICATIONS. 1 INSERT TEE WITH CLAMPS T B'CALIPER TREE 1.0 GPH EIGHT EACH TEN EACH • DRIP VALVE ZONES ARE DESIGNED TO ACCOUNT FOR DIFFERENCES IN PLANT , VALVE SIZE POLY PIPING- PERIMETER LATERALS V J REQUIREMENTS(HYDROZONES)AND SUN EXPOSURE. _ • SWEEP TO SPECIFIED DEPTH 2"TO 4"FROM EDGE SYz"CALIPER TREE 1.0 GPH NINE EACH ELEVEN EACH • CONTRACTOR SHALL ENSURE HYDROZONES ARE VALVED SEPARATELY AS SHOWN ON PLAN. 4"CALIPER TREE 1.0 GPH TEN EACH TWELVE EACH • SITE CONDITIONS MAY DICTATE THAT MULTIPLE SUN EXPOSURES ARE VALVED PVC SCH.e0 NIPPLE 3"MIN.DEPTH s�"APSHED GRAVEL 6 FT.CONIFEROUS TREE 1.0 GPH FOUR EACH 51X EACH TOGETHER DURING THE DESIGN PROCESS.CONTRACTOR SHALL ADJUST EMITTER PVC SCH.40 TEE OR ELL LINE SHE PVC BALL VALVE I EXHAUST HEADER-PVC OR POLY SCHEDULE AS FOLLOWS: a FT.CONIFEROUS'TREE 1.0 GPH SIX EACH NINE EACH •• EMITTER QUANTITIES SHALL REMAIN THE SAME BUT EMITTER GALLONAGES SHALL PVC MAINLINE l BE DOUBLED FOR PLANTS WITH SOUTH AND WEST EXPOSURES. NOTE L =•l l 10 FT.CONIFEROUS TREE 1.0 GPH BGHT EACH TWELVE EACH •• EMITTER QUANTITIES AND GALLONAGE SHALL BE AS SHOWN IN SCHEDULE FOR INSTALL ASSEMBLY TO REST ON GRAVEL SUMP.CONTAIN ENTIRE ASSEMBLY WITHIN BOX.NO VALVE —0 12 FT.CONIFEROUS TREE 1.0 GPH TEN EACH FOURTEEN EACH PLANTS WITH NORTH AND EAST EXPOSURES. BOX EXTENSIONS WILL BE ACCEPTED.PROVIDE 3"-4"CLEARANCE BET TOP OF CONTROL 0 M•• PLANTINGS WITH NORTH AND EAST EXPOSURE SHALL DICTATE VALVE RUN-TIES VALVE SOLENOID AND BOTTOM OF VALVE BOX LID.TOP OF VALVE BOXOX TO TO BE FLUSH WITH FINISH AND CONTRACTOR SHALL ADJUST SCHEDULING ACCORDINGLY. GRADE.VALVE BOx SHALL NOT REST ON DRIP TUBING. DRIP EMITTER - EXISTING PLANTINGS 14 DRIP VALVE IC DRIP - TOP VIEW FiABOVE GRADE 24V-POLY LATERAL CENTER FEED LAYOUT-TYPICAL Date Issuance 2019-08-13 DUELS REVIEW 2019-08-30 PERMIT 0 0 0 O O O 0 O O 0 0 0 0 0 0 O O O O O O p O O O O O O O TEE TO EMITTER TUBING MULCH OR INORGANIC / O MATERIAL,IF APPLICABLE O\�\I //_ POLY LAT..,HEADER FINISH GRADE - ,J6.lui'/' ii111L..r GROWING MEDIA - - NEEDLED ROCK WOOL HYDRORAIN MAX 2" FOAM INSULATION LINE DEPTH '' _J 0 Q • ., 0 c • +4 ROOF MEMBRANE Title GREENROOF MEDIA • 8. ° ed NE SPADING PER SCHEDULE 811 IRRIGATION ROOF MEMBRANE SUBSURFACE DRIP ROOFTOP PLANTING, TYPICAL 18 BUSINESS / BEFORE YOU DETAILS 4111 Know what's below. CALL 3 HORIZONTAL VIEW-GREEN ROOF / Call before you dig. DIG,GRADE. HCHVUTE FOR THE MARKING EMBER UTILITIES. OF Drawing No. UNDERGROUND I R4.00 RECEIVED 09/09/2019 ASPEN BUILDING DEPARTMENT A i,„ 10"ROUND VALVE BOX-BRAND'EV" Hydro I LATERAL TO TREE PIT OR PLANTER ON LID OF VALVE BOX.REFER TO (COORDINATE PENETRATION AND TECHNICAL SPECIFICATIONS. SYSTEMS TYPE K COPPER STUB \ / WATERPROOFING WITH ARCHITECT AND -� MINIMUM EMITTER LENGTH AS REQUIRED `N GENERAL CONTRACTOR) PLANT SIZE PARKING STRUCTURE CEILING-REFER TO ARCH.DRAriINGS FINISH GRADE /��/ - 5 GALLON SHRUBS TH •REE MOISTSRE SENSORS TO BE INSTALLED IN A Water Management& ve • av ,• IIRV ,e v a• av a sv , : A Ai - illii '\�1 CALIPER TREE QTY.REE EACH SITE.WIREwSENSORS TO IRRIGATION EXP RE FOR Irrigation860 Tabor Street,Suite 200 Q TREE II �.. CONTROLLER SENSOR PORT IRRIGATED Lakewood,Colorado R0401 IGHT EACH _ POTS SHALL BE ON A PROGRAM NOT 2^CALIPER TREE TWELVE EACH o:303980.5327 CONDUIT FOR CONTROL WIRES / "CALIPER TREE SIXTEEN EACH INTERRUPTED BY SOIL MOISTURE SENSORS. COPPER ELBOW II ■ - - 1 � / www.hydrosystemskdi.com 24V CONTROL VALVE // 3"CALIPER TREE Tl^lENTY EACH,II 1 `� PVC BALL VALVELATERAL SUPPLY PIFE '` _-/ lb-Ie -,•Ig...1 poi i�i_i_�.. FLOW (WITH IN-LINE CHECK 3Y,"CALIPER TREE TWENTY-TYPO EACH - BRP55 BALL VALVE-PVC x MIP VALVES IF REQUIRED) _ _ v ADAPTERS(2 EACH)DIAMETER TO -� �' REE "� 1" Tf-C K CAPPER MAIN LINE /EQUAL PIPE DIAMETER & LON CALIPER S TREE N TEE�EAGH EACH DEPrH'OF TY PIPE HANGER 10"O.G.AND ON \ FROM P.O.L. - a POLY DRIP SUPPLY _ •"CRUSHED GRAVEL SUMP-t CU.FT, EACH SIDE OF ALL TEC-5 AND 1"C x MIP ADAPTER / T TUBING NO EMITTERS a FT.CONIFEROUS TREE TWENTY-FOUR EACHINIVW ELECTRIC CONTROL VALVES PRESSURE REGULATING FILTER ROOTBALL T TYPE K COPPER LATERAL LINE TO 1"C x MIP ADAPTER PIGAL 6"CLASS 160 PVC SLEEVE.BOTTOM - ROOT ZONE PLANTERS a PENETRATIONS SILENT CHECK VALVE-LEGEND VALVE T-455 a PLANTING BACKFILL MATERIAL 1"C x C UNION .(� PRESSURE MAO BE INLINE AND CONTACT TOP OF EMITTER DRIPLINE(BELOW MULCH 10 FT.CONIFEROUS TREE TWENTY-FOUR EACH L 01 PAD LOCK AND FABRIC,AROUND THE ROOT 12 FT.LONIFFen15 TREE TWENTY-EIGHT EACH _ _I BALL)6"FROM ROOTBALL NOTE:DIAMETERS OF BALL VALVES,PVC FITTINGS AND NIPPLES STAKE DRIP PIPE TO EDGE OF ROOTBALL NOTES. [• 4µ CA SHALL EQUAL ELECTRIC CONTROL VALVE DIAMETER PVC PRESSURE MAINLINE OR LATERAL EMITTERS SHALL BE EQUALLY SPACED AROUND IllIII `�•�:• APPLY TEFLON TAPE TO ALL MALE THREADED FITTINGS AND TRUNK GE OF EXCAVATION ROOT BALL. FL - 1`- • EMITTER FLOW RATE PER SCHEDULE. THREADED NIPPLES. EMITTER DRIPLINE(BELOW MULCH • DRIPLINE EMITTER SPACING PER SCHEDULE. 6 6 AND FABRIC,AROUND THE ROOT BALL)6"FROM ROOTBALL DRIP CONTROL VALVE S LOCKABLE BALL VALVE 20 SUBSURFACE EMITTER TREE RING ® MOISTURE SENSOR w 0 BUILDING STRUCTURE(TYP.) zFp w o U /< Z d 7 Q Project 6723-931 Gibson Street Z w Location Aspen 0 z Point of Connection Description Tap 1 W Point of Connection Size 1" CO Q Controller Letter A /�� W 0 Date Prepared 26-3u1-19 (/) m Allowable Overhead Watering Window:six nights per week,sir hours per night(36 hours/week). 0 (7 Estimated weekly application for Spray Irrigated Blue Gramma=0,65" m Estimated weekly application for Spray Irrigated Fescue Turt=1.]2" Estimated weekly application for Drip Irrigated Shrubs&Trees=0.78" Estimated weekly application for Drip Irrigated Trees=0.78" Run Concurrent with Spray Irrigation CO Prepared by HydroSystems-KDI,Inc. _ - //��'� Design CD Nozzle Precip. Zone Peak Daily Zone Water Operating Zone Irrigation (if Rate Flow Demand runtime Use Pressure land cape Zone Number Plant Type(s) Description Aeolic. (in/hr) (GPM) (in/wk) (min) (gal/wk) (psi) Hydr zone Al Fescue Turf I Head'Popup 1.57 6 1.72 11.0 395 30 A2 Fescue Turf Drip-Inline 0.64 1 1.72 26.9 161 25 A3 Shrubs&Trees Drip-Point Source 0.50 2 0.78 15.6 187 25 _ A4 fescue Turf Head Popup 1.57 10 1.72 11.0 658 30 AS BlueGramma Head Popup I.SI 6 0.65 4.1 148 30 A6 TeIc0e Turf Head-POppp 1.57 6 1.72 11.0 395 30 A7 Slue Gramma Head-Vopup I 57 8 0.65197 30 AS Trees Drip-Point Source 0 a 3 0.38 15'6 281 25 1 A9 BlueGramma Head-Popup 1.57 9 0.65 4.1 222 30 A10 BlueGramma Head•Popup 1 57 9 0.65 4.1 222 30 Date Issuance A11 Bme Gramma Head-Popup 1.57 8 0.65 4.1 197 30 2019-08-13 WELS REVIEW Alz ue Turf Head-Popup 1 57 10 1.72 11.0 658 39 4 2019-08-30 PERMIT A13 Trees Drip•Paint Source 0 50 2 0./8 15 6 187 25 2 A14 BlueGramma Head-Popup 1 56 6 0.65 148 30 A15 •BlueGramma Head-Popup 1.57 10 065 4.1 247 30 A16 Fescue Turf Head-Popup 1.57 9 1.72 11.0 592 30 A37 BlueGramma Head-Popup 1,57 7 0.65 4,1 173 30 A18 Shrubs&Trees Drip-Point Source 0.50 3 0.78 15.6 280 25 A19 Fescue Turf Head-Popup 1,57 10 1,72 11.0 658 30 A20 BlueGramma Head-Popup 1.57 10 0.65 4.1 247 30 A21 BlueGramma Head-Popup 1.57 10 0.65 4.1 247 30 A22 Fescue Turf Head•Popup 1.5I 10 1.72 11.0 658 30 A23 Fescue Turf Head-Popup 1.57 10 1.72 11.0 658 30 A24 Shrubs&Trees Drip-Point source 0.50 2 0.78 15.6 187 25 A25 Fescue Turf Head-Popup 1.57 10 1.72 11,0 658 30 A26 Shrubs&Trees Drip-Point Source 0.50 2 0.78 15.6 187 25 A27 Shrubs&Trees Drip-Point Source 0.50 3 0.78 15.6 280 25 1 A28 Trees Drip-Inline _ 0.64 _ 2 _ 0.78 _ 12.2 146 25 1 .9 Trees Drip-Inline 0.64 2 0.78 12.2 146 25 CONTROLLER CHART A DIRECTORY Title IRRIGATION NOTES IR1.00 IRRIGATION IRRIGATION SCHEDULE IR1.00 811 DETAILS AND IRRIGATION PLANS IR2.00 CHARTS IRRIGATION DETAILS IR3.00 - IR5.00 Know what's below. Call before you dig. Drawing No, IRRIGATION CHARTS IR5.00 DIG, OF BHpERGRpUNpNENRERUTILInEa. I R5.00 RECEIVED 09/09/2019 ASPEN BUILDING DEPARTMENT