Loading...
HomeMy WebLinkAboutFile Documents.933 E Hyman Ave.0128-2021-BRES (18)Parks Markup 1 - 933 E Hyman Avenue - 0128-2021-BRES Page: 1 Author: davidr Date: 12/13/2021 11:35:17 AM File Name: 90.landscape arch.20211001.pdf City Forester to specify in tree permit requirements for removal of roots, soil addition and backfill instructions. 1 (11) Page: 1 Author: davidr Date: 12/13/2021 11:36:20 AM File Name: 90.landscape arch.20211001.pdf Show existing drywell location. Page: 1 Author: davidr Date: 12/13/2021 11:36:56 AM File Name: 90.landscape arch.20211001.pdf This may constitute a hedge row which are not allowed in the City of Aspen. Confirm with COMDEV. Page: 1 Author: davidr Date: 12/13/2021 11:35:28 AM File Name: 90.landscape arch.20211001.pdf Change this to read: City Forester and Consultant. Page: 1 Author: davidr Date: 12/13/2021 11:38:19 AM File Name: 90.landscape arch.20211001.pdf Air-spade at back of dry stacked wall to expose roots of neighbors trees and all the way to the new electric line for spa. This will need to occur prior to Parks signing off on proposed plantings and spa location. New service line will need to be snaked under roots as there will be no cutting of roots over 1.5" in diameter. Page: 1 Author: davidr Date: 12/13/2021 11:37:08 AM File Name: 90.landscape arch.20211001.pdf Submit for a tree dripline excavation permit. City Forester to determine impacts to roots after inspection. Page: 1 Author: davidr Date: 12/13/2021 11:37:23 AM File Name: 90.landscape arch.20211001.pdf Tree Protection Fencing must be installed at the driplines of existing trees and a mulch bedding at least 6" deep is required in driplines where activity will occur. Page: 1 Author: davidr Date: 12/13/2021 11:37:18 AM File Name: 90.landscape arch.20211001.pdf Air-spade along this area. Page: 1 Author: davidr Date: 12/13/2021 11:35:24 AM File Name: 90.landscape arch.20211001.pdf No storage of material, activity, or machinery allowed with the driplines of trees. SERVICE 72 HOU 3.THE CONTRACTAND INFORMATIO 4.WHERE PROPO PROVIDE SMOOT 5.CONTRACTOR S 6.ALL GRADES S 7.THE CONTRACTEXPRESS WRITTESHALL BE PROTE 8.STRIP ALL TOPSTHE SUB-SOIL. 9.CLEAR AND GRROOTS ARE TO BPER SPECIFICATI 10.STORM WATERFLOODING OF ON 11.ALL AREAS DI SPECIFIED. 12.THE EARTHWO MINOR ADJUSTMTO HELP BALANC 13.THE EARTHWOSITE BARROW PI S 75°09'11" E 30.00'S 75°09'11" E 30.00'ITH 8643 ER RATE FND PK NAIL WITH SHINER, PLS 28643City Forester to specify in tree permit requirements for removal of roots, soil addition and backfill instructions. SPA YWELL WROUGHT CE ' Show existing drywell location. 7937.627937.00 ASPHALT ALLEY 22'-3 3/4"G GAS GAS GAS GAS GAS GAS GAS GAS GAS GA S GA S GA S GA S GA S GA S G A S GAS GAS GAS IVB IVB G E S 14°50 ' 4 9 " W 100.00' N 75°09'11" W 30.00'N 75°09'11" W 30.00' N 14°50'49 " E 100.00' 1.0' 31.4' 4.5' 7.1' 20.9' 15.8' 10.0' 17.5' 4.5' S 14°50 ' 4 9 " W 100.00' S 75°09'11" E 30.00'S 75°09'11" E 30.00' FND PK NAIL WITH SHINER, PLS 28643 RING FOUNDNDER ASPHALT T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 T12 T26 T27 T28 FF3 FF2 FF4 C1 R1 LOT F LO T G LOT HNOT A PART LOT ET A PART AC AC ACAC ABANDONED TELEPHONE PEDESTAL 8" DIAMETER STORM GRATE 7938.09 GAS METER AD J A C E N T B U I L D I N G RAILROAD TIE RETAINING WALL TRENCH DRAIN E ELECTRIC TRANSFORME R S SEWER MANHOLE IRRIGATION SPIGOTS GAS METER AD J A C E N T BU I L D I N G GAT E BRETAININ WALL WINDOW WELLS (TYP.) AC UNITS ON CONCRETE PAD CONCRETEDRIVEWAY PILLARS (TYP.) WOOD PANEL FENCE WOODPANELFENCE WROUGHTIRONFENCE EXISTINGUNDERGROUNDGAS LINE UNDERGROUN D ELECTRIC LINE UNDERGROUND TELEPHONE LINE UNDERGROUND CABLE LINE 5' REAR SETBACKPER CITY OF ASPEN LOT I NOT A PAR FND PK SHINE 60 3 9 6038 60 3 7 60 3 8 RELOCATE EXISTINGGAS, TELE. AND ELECLINES AROUND SPARUN 220 V ELECLINE TO SPA A D NEW GAS LINE 2% S L O P E 7'-3" B C 37.12MAINT.ACCESS BS 37.62 TS 38.12 EXPOSED AGGREGATEPATIO AND STEP(236 SF) SNOWMELTEDINCLUDING MAINT. ACCESS AREA (1) 6" RISER EL E C EL E C 38.75 12 ' - 0 " 8'-0" INSTALL 220V SUB-PANELFOR SPA 8" HIGHNDA VANGUARDSPA(7'3" X 7'3" X 36" HT) 38.75 TOP OFSPA39.79 BW 37.62 BW 37.12 38.34 TW 37.62 4'- 3 " LIGHTS AND EASTA TIONS) NEW ELECTRIC LINE TO SPA (220 V) This may constitute ahedge row which are not allowed in the City of Aspen. Confirm with COMDEV. TITLED: ____________________________________________ DATED: ____________________________________________ BENCH MARK LOCATED: ____________________________________________ 1.CONTRACTOR SHALL VERIFY GRADES AND NO 2.LOCATION, SUPPORT, PROTECTION AND RESTOAPPURTENANCES SHALL BE THE RESPONSIBILITRESPONSIBILITY OF THE CONTRACTOR, PRIOR TFIELD THE ACTUAL LOCATIONS AND ELEVATIONSSHOWN ON THE PLANS OR NOT. THE CONTRACTSERVICE 72 HOURS PRIOR TO CONSTRUCTION. 3.THE CONTRACTOR SHALL USE THE SITE LAYOUAND INFORMATION. 4.WHERE PROPOSED GRADES MEET EXISTING, CPROVIDE SMOOTH TRANSITION BETWEEN EXIST 5.CONTRACTOR SHALL MAINTAIN POSITIVE DRA 6.ALL GRADES SHOWN ARE FINISHED GRADES. 7.THE CONTRACTOR SHALL NOT REMOVE ANY TEXPRESS WRITTEN CONSENT OF THE CONSULTASHALL BE PROTECTED AS DIRECTED BY THE CO 8.STRIP ALL TOPSOIL WITHIN THE GRADING LIMITHE SUB-SOIL. 9.CLEAR AND GRUB ENTIRE AREA WITHIN LIMITS S 75°09'11" E 30.00' FND PK NAIL WITH SHINER, PLS 28643 Change this to read: City Forester and Consultant. 7937.62 UPRIGHT JUNIPERS 7937.00 ASPHALT ALLEY 10'-7 1/2" 6'-0 3/4" 22'-3 3/4" GAS GAS GAS GAS GAS GAS GAS GAS GA S GA S GA S GA S GA S GA S G A S GAS GAS GAS IVB IVB G G E S 14°50'49 " W 100.00' N 75°09'11" W 30.00'N 75°09'11" W 30.00' N 14°50'49" E 100.00' 26.1' 6.6' 10.0' 3.5' 2.2'2.7'2.7' 2.4' 17.3' 1.0' 31.4' 4.5' 7.1' 20.9' 15.8' 10.0' 17.5' 4.5' 15.6' 15.0' S 14°50'49" W 100.00' RING FOUNDUNDER ASPHALT FLPATIO T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 T12 T26 T27 T28 FF3 FF1 FF2 FF4 C1 R1 933 E. HYMAN AVE.MULTI-LEVELWOOD AND STONEBUILDING LO T F LOT G LOT ENOT A PART AC AC ACAC ABANDONED TELEPHONE PEDESTAL MRAILROAD TIE RETAINING WALL TRENCH DRAIN E ELECTRIC TRANSFORMER S SEWER MANHOLE IRRIGATIONSPIGOTS GAS METER AD J A C E N T BU I L D I N G W WWELL GAT E FLA G S T O N E PA T H AC CONCRETEDRIVEWAY PILLARS (TYP.) WOODPANELFENCE WROUGHTIRONFENCE EXISTINGUNDERGROUNDGAS LINE UNDERGROUND ELECTRIC LINE UNDERGROUN D TELEPHONE LINE UNDERGROUN D CABLE LINE 5' REAR SETBACKPER CITY OF ASPEN 6 0 3 9 6038 60 3 7 60 3 8 RELOCATE EXISTINGGAS, TELE. AND ELECLINES AROUND SPARUN 220 V ELECLINE TO SPA A D NEW GAS LINE 2% SL O P E 7'-3" B C 37.12MAINT.ACCESS BS 37.62 TS 38.12 EXPOSED AGGREGATEPATIO AND STEP(236 SF) SNOWMELTEDINCLUDING MAINT. ACCESS AREA (1) 6" RISER ELE C EL E C HOT TUB PLAN 38.75 12 ' - 0 " 8'-0" INSTALL 220V SUB-PANELFOR SPA DRYSTACK 12-18" HIGHWALL ON SOUTH ANDWEST SIDES OF SPA VANGUARDSPA(7'3" X 7'3" X 36" HT) 38.75 TOP OFSPA39.79 BW 37.62 BW 37.12 38.34 TW 37.62 4'- 3 " WALL - STEP LIGHTS3 ON NORTH AND EASTSIDES OF SPATOTAL OF 6(SEE ELEVATIONS) NEW ELECTRIC LINE TO SPA (220 V)DRYSTACKWALL 4" THICK EXPOSED AGGREGATE PAD FOR SPAREINFORCED W/ REBARLEAVE OPEN 4' X 4' GRAVEL AREA IN CENTER AND CONNECT TO EXISTING DRYWELL SPARTANJUNIPER EXISTING WROUGHTIRON FENCE 3'-0 " TS 38.12 BW 37.12 THICKENED EDGE EXPOSED AGGREGATE PATIOREINFORCED WITH REBARSNOWMELTED EXPOSED AGGREGATEPAVING - SNOWMELT EXISTING FENCE VANGUARDSPA CCESS SCALE: 1/4" = 1' SCALE: 1/4" = 1' TOP OF SPA39.79 TOP OF SPA39.79 4" THICK CONCRETE PADFOR SPA - SNOWMELTED BW 36.7910 " 1'-7"2'-2" 3'- 0 " 1'-8 " 1'- 4 " GRAVELINFIELD 4' X 4' 7'-5" 2'- 2 " 3.5 " TW 39.50 8'-0"D Air-spade at back ofdry stacked wall toexpose roots ofneighbors trees andall the way to thenew electric line forspa. This will needto occur prior toParks signing off on proposed plantingsand spa location.New service linewill need to besnaked under rootsas there will be nocutting of roots over1.5" in diameter. 7937.62 UPRIGHT JUNIPERS 7937.00 ASPHALT ALLEY 10'-7 1/2" 6'-0 3/4" 22'-3 3/4"G GAS GAS GAS GAS GAS GAS GAS GAS GA GA S GA S GA S GA SGA S GA S GA S GAS GAS GAS IVB IVB G G E S 14°50'4 9 " W 100.00' N 75°09'11" W 30.00'N 75°09'11" W 30.00' N 14°50'49" E 100.00' 26.1' 6.6' 10.0' 3.5' 2.2'2.7'2.7' 2.4' 17.3' 1.0' 31.4' 4.5' 7.1' 20.9' 15.8' 10.0' 17.5' 4.5' 15.6' 15.0' S 14°50'49" W 100.00' FND PK NA SHINER, PRING FOUNDUNDER ASPHALT FLAPATIO T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 T12 T26 T27 T28 FF3 FF1 FF2 FF4 C1 R1 933 E. HYMAN AVE.MULTI-LEVELWOOD AND STONEBUILDING LOT F LOT G LOT ENOT A PART AC AC ACAC ABANDONED TELEPHONE PEDESTAL 8" DIASTOR7938 GASMETER AD J A C E N T BU I L D I N G ADPI RAILROAD TIE RETAINING WALL TRENCH DRAIN E ELECTRIC TRANSFORMER S SEWER MANHOLE IRRIGATION SPIGOTS GASMETER ADJA C E N T BU I L D I N G WIN WWELL GAT E FLA G S T O N E PA T H BOULDER RETAININ WALL WI WELLS ( AC UNITS ON CONCRETE PAD CONCRETEDRIVEWAY PILLARS (TYP.) BUILDING OVERHANG WOOD PA FENCE WOODPANELFENCE WROUGHTIRONFENCE EXISTINGUNDERGROUNDGAS LINE UNDERGROUND ELECTRIC LINEUNDERGROUND TELEPHONE LINE UNDERGROUND CABLE LINE 5' REAR SETBACKPER CITY OF ASPEN 60 3 9 6038 60 3 7 60 3 8 RELOCATE EXISTINGGAS, TELE. AND ELECLINES AROUND SPARUN 220 V ELECLINE TO SPA A D NEW GAS LINE 2% SL O P E 7'-3" B C 37.12MAINT.ACCESS BS 37.62 TS 38.12 EXPOSED AGGREGATEPATIO AND STEP(236 SF) SNOWMELTEDINCLUDING MAINT. ACCESS AREA (1) 6" RISER ELE C EL E C HOT TUB PLAN 38.75 12 ' - 0 " 8'-0" INSTALL 220V SUB-PANELFOR SPA DRYSTACK 12-18" HIGHWALL ON SOUTH ANDWEST SIDES OF SPA VANGUARDSPA(7'3" X 7'3" X 36" HT) 38.75 TOP OFSPA39.79 BW 37.62 BW 37.12 38.34 TW 37.62 4'- 3 " WALL - STEP LIGHTS3 ON NORTH AND EASTSIDES OF SPATOTAL OF 6(SEE ELEVATIONS) NEW ELECTRIC LINE TO SPA (220 V) EXISTINGWOOD PANELFENCE DRYSTACKWALL BS 37.62TS 38.12 4" THICK EXPOSED AGGREGATE PAD FOR SPAREINFORCED W/ REBARLEAVE OPEN 4' X 4' GRAVEL AREA IN CENTER AND CONNECT TO EXISTING DRYWELL SPARTANJUNIPER EXISTING WROUGHTIRON FENCE 3'- 0 " YSTACKLL TS 38.12 BW 37.12 THICKENED EDGE EXPOSED AGGREGATE PATIOREINFORCED WITH REBARSNOWMELTED EXPOSED AGGREGATEPAVING - SNOWMELT EXISTING FENCE VANGUARDSPA SPA AT SPA ACCESS SCALE: 1/4" = 1' SCALE: 1/4" = 1' TOP OF SPA39.79 TOP OF SPA39.79 6" 4" THICK CONCRETE PADFOR SPA - SNOWMELTED BW 36.79 DGEAST AND OF SPA 10 " 1'-7"2'-2" 3'- 0 " 1'-8 " 1'- 4 " GRAVELINFIELD 4' X 4' 7'-5" 2'- 2 " 1'-8 " 3.5 " TW 39.50TW 39.50 8'-0"X 4' GRAVEL INFIELD Submit for a treedripline excavationpermit. City Foresterto determine impactsto roots afterinspection. 7937.62 UPRIGHT JUNIPERS 7937.00 ASPHALT ALLEY 10'-7 1/2" 6'-0 3/4" 22'-3 3/4" GAS GAS GAS GAS GAS GAS GAS GAS GA S GA S GA S GA S GA S GA S G A S GAS GAS GAS IVB IVB G G E S 14°50'4 9 " W 100.00' N 75°09'11" W 30.00'N 75°09'11" W 30.00' N 14°50'49" E 100.00' 26.1' 6.6' 10.0' 3.5' 2.2' 2.7'2.7' 2.4' 17.3' 1.0' 31.4' 4.5' 7.1' 20.9' 15.8' 10.0' 17.5' 4.5' 15.6' 15.0' S 14°50'49" W 100.00' RING FOUNDUNDER ASPHALT FLAGSTONE PATIO T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 T12 T13 T26 T27 T28 FF3 FF1 FF2 FF4 C1 R1 933 E. HYMAN AVE.MULTI-LEVELWOOD AND STONEBUILDING LO T F LO T G LOT ENOT A PART AC AC ACAC ABANDONED TELEPHONE PEDESTAL MRAILROAD TIE RETAINING WALL TRENCH DRAIN E ELECTRIC TRANSFORMER S SEWER MANHOLE IRRIGATION SPIGOTS GASMETER AD J A C E N T BU I L D I N G ADJACENTWINDOWWELL GA T E FLA G S T O N E PA T H AC CONCRETEDRIVEWAY PILLARS (TYP.) WOODPANELFENCE WROUGHTIRONFENCE EXISTINGUNDERGROUNDGAS LINE UNDERGROUND ELECTRIC LINE UNDERGROUND TELEPHONE LINE UNDERGROUND CABLE LINE 5' PER CITY OF A 5' REAR SETBACKPER CITY OF ASPEN 6 0 3 9 6038 60 3 7 60 3 8 RELOCATE EXISTINGGAS, TELE. AND ELECLINES AROUND SPARUN 220 V ELECLINE TO SPA A D NEW GAS LINE 2% SL O P E 7'-3" B C 37.12MAINT.ACCESS BS 37.62 TS 38.12 EXPOSED AGGREGATEPATIO AND STEP(236 SF) SNOWMELTEDINCLUDING MAINT. ACCESS AREA (1) 6" RISER EL E C EL E C 38.75 12 ' - 0 " 8'-0" INSTALL 220V SUB-PANELFOR SPA DRYSTACK 12-18" HIGHWALL ON SOUTH ANDWEST SIDES OF SPA VANGUARDSPA(7'3" X 7'3" X 36" HT) 38.75 TOP OFSPA39.79 BW 37.62 BW 37.12 38.34 TW 37.62 4'- 3 " WALL - STEP LIGHTS3 ON NORTH AND EASTSIDES OF SPATOTAL OF 6(SEE ELEVATIONS) NEW ELECTRIC LINE TO SPA (220 V) DRYSTACKWALL 4" THICK EXPOSED AGGREGATE PAD FOR SPAREINFORCED W/ REBARLEAVE OPEN 4' X 4' GRAVEL AREA IN CENTER AND CONNECT TO EXISTING DRYWELL SPARTANJUNIPER EXISTING WROUGHTIRON FENCE 3'-0 " TS 38.12 W 37.12 THICKENED EDGE EXPOSED AGGREGATE PATIOREINFORCED WITH REBARSNOWMELTED EXPOSED AGGREGATEPAVING - SNOWMELT EXISTING FENCE VANGUARDSPA CCESS SCALE: 1/4" = 1' SCALE: 1/4" = 1' TOP OF SPA39.79 TOP OF SPA39.79 4" THICK CONCRETE PADFOR SPA - SNOWMELTED BW 36.7910 " 1'-7"2'-2" 3'- 0 " 1'-8 " 1'- 4 " GRAVELINFIELD 4' X 4' 7'-5" 2'- 2 " 3.5 " TW 39.50 8'-0" SCALE: 1/4" = 1' Tree ProtectionFencing must beinstalled at the driplines of existingtrees and a mulchbedding at least 6" deep is required indriplines where activitywill occur. 3'- 0 " DRYSTACK WALL TS 38.12 BW 37.12 SPARTAN JUNIPER THICK EXPO REINF SNOW VANGUARDSPA D SECTION AT SPA ACCESS TOP OF SPA39.79 4" THI FOR S 1'- 8 " 1'- 4 " 3.5 " TW 39.50TW 39.50 8'-0"4' X 4' GRAVEL INFIELD Air-spade along this area. 1.CONTRACT 2.LOCATION,APPURTENARESPONSIBIFIELD THE ACSHOWN ON TSERVICE 72 H 3.THE CONTRAND INFORM 4.WHERE PRPROVIDE SM 5.CONTRACT 6.ALL GRADE 7.THE CONTR EXPRESS WRSHALL BE PR 8.STRIP ALL THE SUB-SO 9.CLEAR AND ROOTS ARE S 75°09'11" E 30.00' FND PK NAIL WITH SHINER, PLS 28643 No storage of material, activity, or machinery allowed with the driplines of trees. DONE, SEE NEW SITE PREPARATION NOTE ADDED TO LANDSCAPE ARCHITECT’S PLANS WHICH ADDS THE SUGGESTED LANGUAGE TO THE PLANS WE COULD NOT FIND A DRYWELL AFTER DOING EXPLORATORY INVESTIGATION. WE HAVE REMOVED IT FROM THE PLAN AND WILL NOTIFY THE PARKS DEPARTMENT IF WE LOCATE ONE. IT WAS LOCATED IN THIS VICINITY WHEN THE HOME WAS ORIGINALLY PROPOSED, BUT COULD NOT FIND IT. JUNIPERS HAVE BEEN STAGGERED AND NATIVE NINEBARK SRHUBS ADDED PER COMMUNITY DEVELOPMENT RECOMMENDATION TO VARY THE DESIGN TO AVOID A HEDGEROW PLANTING. REVISED AS REQUESTED DONE, THIS LANGUAGE HAS BEEN ADDED TO THE REVISED LANDSCAPE ARCHITECT’S PLANS ANNOTATED WITH CLOUDED AREA AND A SITE PREPARATION AND GRADING NOTE ADDED TO THE PLANS. DONE, A NOTE WAS ADDED TO LANDSCAPE ARCHITECT’S PLAN INSTRUCTING CONTRACTOR TO APPLY FOR TREE DRIPLINE EXCAVATION PERMIT DONE, A NOTE HAS BEEN ADDED TO LANDSCAPE ARCHITECT’S PLANS WITH FENCING SHOWN AT TREE DRIPLINES WITH FURTHER NOTATION LIMITING THE STORAGE OF MATERIAL, ACTIVITY OR MACHINERY WITHIN THE DRIPLINES OF TREES DONE, A NOTE WAS ADDED TO LANDSCAPE ARCHITECT’S PLAN INSTRUCTING CONTRACTOR TO AIRSPADE IN THIS AREA OF THE NEIGHBOR’S TREE DRIPLINE NOTE HAS BEEN REVISED AS REQUESTED ON LANDSCAPE ARCHITECT’S PLANS ANSWERS/REPLIES TO PARK’S DEPARTMENT REQUESTS IN PINK BY LANDSCAPE ARCHITECT CHRISTIE JENSEN christiejensen@christiejensen.com or 970-948-1535 Page: 1 Author: davidr Date: 12/13/2021 11:41:37 AM File Name: 90.landscape arch.20211001.pdf Note: Maximum size for junipers is 10 gallon, if allowed. Page: 1 Author: davidr Date: 12/13/2021 11:35:45 AM File Name: 90.landscape arch.20211001.pdf Please confirm whether excavation in this area will be done by hand or machine.... UPRIGHT JUNIPERS G GAS METER AD J A C E N T B U I L D I N G WROUGHT IRON FENCE EXISTING UNDERGROUND UNDECABLE LIN Note: Maximum size for junipers is 10 gallon, if allowed. 937.00 ASPHALT ALLEY 22'-3 3/4" GAS GAS GAS GAS GAS G A S GAS GAS GAS N 75°09'11" W 30.00' RING FOUNDUNDER ASPHALT T1 T2 T3 T4 T5 TRENC E S SEWER MANHOLE GA T E WOODPANELFENCE UNDERGROUN D TELEPHONE LINE 5' REAR SETBA PER CITY OF A 6 0 3 9 6038 8A D 2% S L O P E 7'-3" B C 37.12MAINT.ACCESS BS 37.62 TS 38.12 (1) 6" RISER EL E C EC HOT TUB PLAN 38.75 12 ' - 0 " 8'-0" DRYSTACK 12-18" HIGHWALL ON SOUTH ANDWEST SIDES OF SPA VANGUARDSPA(7'3" X 7'3" X 36" HT) 38.75 TOP OFSPA39.79 BW 37.62 BW 37.12 38.34 TW 37.62 4'- 3 " TOTAL OF 6(SEE ELEVATIONS) NED EDGE ED AGGREGATE PATIORCED WITH REBARELTED EXPOSED AGGREGATEPAVING - SNOWMELT CALE: 1/4" = 1' K CONCRETE PADA - SNOWMELTED Please confirm whether excavation in this area will be done by hand or machine.... JUNIPERS HAVE BEEN SPECIFIED AS 10 GALLON SIZE ALL EXCAVATION WILL BE DONE BY HAND AND NOTATED ON PLANS AS SUCH