Loading...
HomeMy WebLinkAboutFile Documents.931 Gibson Ave.0037-2019-BRES (34)The City of Aspen These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK 09/04/2019 10/25/2019 Reviewed by Engineering 01/30/2020 8:54:00 PM "It should be known that this review shall not relieve the applicant of their responsibility to comply with the requirements of the City of Aspen. The review and approval by the City is offered only to assist the applicant's understanding of the applicable Engineering requirements." The issuance of a permit based on construction documents and other data shall not prevent the City of Aspen from requiring the correction of errors in the construction documents and other data. External Energy Use Approved RREMP CREMP PERMIT #:_______________DATE:________ SNOWMELT:_____________________________ POOL: _____________________________ SPA: _____________________________ OFFSET:________________________________ REMP SHEET: __________________________ REVIEWED BY: _________________________ SNOWMELT SYSTEM AND EQUIPMENT MANDATORY REQ’S. All snowmelt systems shall meet the following: -Any portions in the Right of Way must be on a separate zone. A ROW permit and Permanent Encroachment License are required. -R10 insulation shall be installed under the area to be snow melted or R5 insulation shall be installed under and at the slab edges. (Ordinance 11 Series 2011) -Automatic controls installed for system shut off when pavement temperature is above 50°F and no precipitation is falling. (2009 IECC Sec. 403.8 & 503.2.4.5) -Automatic or manual controls installed for system shut off when outdoor temperature is above 40°F. (2009 IECC Sec. 403.8 & 503.2.4.5) -Inspection by testing hydrostatically at 1½ times max system design pressure, but not less than 100psi, for 15minutes. (2009 IMC Sec. 1208.1) MINIMUM BOILER AFUE: _________________ X 0037-2019-BRES 1/31/20 1554.80 sq ft A1.3 95% None JH Grills/covers over emergency escape openings shall be releasable or removable from the inside without the use of key, tool, special knowledge or force exceeding 15 lbs - Ord. 40 - 2016. GLASS IN GUARDS AND HANDRAILS Glass in guards and handrails shall be two plies equal thickness laminated glass. Tempered glass is only permitted where not above a walking surface and when a top rail that is either self-supported (glass infill panels) or is supported by a minimum of three panes of glass. IRC 308.7/IBC 2407. SNOWMELT SYSTEM AND EQUIPMENT MANDATORY REQ'S All snowmelt systems shall meet the following: - Any portions in the Right of Way must be on a separate zone. A ROW permit and Permanent Encroachment License are required. - R10 insulation shall be installed under the area to be snowmelted or R5 insulation shall be installed under the slab edges. (Ordinance 11 Series 2011) - Automatic controls installed for system shut off when pavement temperature is above 50°F and no precipitation is falling. (2015 IECC R403.9 and C403.2.4.5) - Automatic or manual controls installed for system shut off when outdoor temperature is above 40°F. (2015 IECC R403.9 and C403.2.3.5) - Inspection by testing hydrostatically at 1.5 times max system design pressure, but not less than 100psi, for 15 minutes. (2015 IMC 1208.1) Snow stops required where snow can slide onto potentially occupied areas such as walkways, parking areas, etc. or do damage to property such as utility meters - IBC 1513/COA 8.20.020(z). Recessed luminaires installed in building thermal envelope shall be sealed and IC-rated – IECC sec R402.4.5 Any recessed light fixtures in contact with insulation must be IC rated. Electric vehicle charging (IRC 309.6). Newly constructed one- or two-family dwellings and townhouses with a dedicated attached or detached garage shall facilitate future installation and use of electric vehicle chargers. For each dwelling unit, a 208/240-volt individual branch circuit or a listed raceway to accommodate a future individual branch circuit shall be installed. The raceway shall not be less than trade size 1 (nominal 1-inch inside diameter). The raceway shall originate at the main service or subpanel and shall terminate into a listed cabinet, box or other enclosure, and in close proximity to the proposed location of the electric vehicle charger. Raceways are required to be continuous at enclosed, inaccessible or concealed areas and spaces. The service panel or subpanel circuit directory shall provide capacity to install a 40-ampere minimum dedicated branch circuit and space(s) reserved to permit installation of a branch circuit overcurrent device. Electrical vehicle supply equipment shall be installed in accordance with NFPA 70. 20 Exception: Additions and alterations to existing one- or two-family dwellings and townhomes constructed per the IRC are exempt from this requirement. SPECIAL INSPECTION REQUIRED: -Structural steel welding: Field & Shop -High strength bolting -Epoxy anchors -Intumescent paint -Spray applied fire resistive materials -Permanent micropiles Special inspection is required per 2015 IBC section 1704. Inspector to verify that copy of agreement for inspection program to be on the job site prior to performing any inspections. A copy of all Special Inspector field reports to be on the job site for inspectors' review if requested. Failure to comply may result in denial of inspection. 0037-2019-BRES BMH Investments LTD 931 Gibson Ave 273707400004 Ice dam barrier consisting of 2 layers of underlayment or a self-adhering polymer modified bitumen sheet shall be used from eave edges to 6' within the exterior wall line, 18" up from centerline of valleys, and 24" up any vertical walls - COA amendment to IRC 905.2.7.1. Ice dam barrier consisting of 2 layers of underlayment or a self-adhering polymer modified bitumen sheet shall be used from eave edges to 6' within the exterior wall line, 18" up from centerline of valleys, and 24" up any vertical walls - COA amendment to IRC 905.2.7.1.