These plans must be kept at the
building site or inspection
delays may occur. Construction
shall conform to these plans. All
changes shall be approved by
the building official.
Field Plan Set Must Be Printed In Color
SEPARATE PERMITS ARE
REQUIRED FOR ELECTRICAL,
PLUMBING, MECHANICAL, OR
FIRE SPRINKLER WORK
09/04/2019
10/25/2019
Reviewed by Engineering
01/30/2020 8:54:00 PM
"It should be known that this review shall not
relieve the applicant of their responsibility to
comply with the requirements of the City of
Aspen. The review and approval by the City is
offered only to assist the applicant's
understanding of the applicable Engineering
requirements." The issuance of a permit based
on construction documents and other data shall
not prevent the City of Aspen from requiring the
correction of errors in the construction
documents and other data.
External Energy Use Approved
RREMP CREMP
PERMIT #:_______________DATE:________
SNOWMELT:_____________________________
POOL: _____________________________
SPA: _____________________________
OFFSET:________________________________
REMP SHEET: __________________________
REVIEWED BY: _________________________
SNOWMELT SYSTEM AND EQUIPMENT MANDATORY REQ’S.
All snowmelt systems shall meet the following:
-Any portions in the Right of Way must be on a separate zone. A ROW
permit and Permanent Encroachment License are required.
-R10 insulation shall be installed under the area to be snow melted or R5
insulation shall be installed under and at the slab edges. (Ordinance 11
Series 2011)
-Automatic controls installed for system shut off when pavement
temperature is above 50°F and no precipitation is falling. (2009 IECC
Sec. 403.8 & 503.2.4.5)
-Automatic or manual controls installed for system shut off when outdoor
temperature is above 40°F. (2009 IECC Sec. 403.8 & 503.2.4.5)
-Inspection by testing hydrostatically at 1½ times max system design
pressure, but not less than 100psi, for 15minutes. (2009 IMC Sec.
1208.1)
MINIMUM BOILER AFUE: _________________
X
0037-2019-BRES 1/31/20
1554.80 sq ft
A1.3
95%
None
JH
Grills/covers over emergency escape
openings shall be releasable or
removable from the inside without the
use of key, tool, special knowledge or
force exceeding 15 lbs - Ord. 40 - 2016.
GLASS IN GUARDS AND HANDRAILS
Glass in guards and handrails shall be two plies equal thickness
laminated glass. Tempered glass is only permitted where not
above a walking surface and when a top rail that is either
self-supported (glass infill panels) or is supported by a minimum of
three panes of glass. IRC 308.7/IBC 2407.
SNOWMELT SYSTEM AND EQUIPMENT MANDATORY REQ'S
All snowmelt systems shall meet the following:
- Any portions in the Right of Way must be on a separate zone. A ROW permit
and Permanent Encroachment License are required.
- R10 insulation shall be installed under the area to be snowmelted or R5 insulation
shall be installed under the slab edges. (Ordinance 11 Series 2011)
- Automatic controls installed for system shut off when pavement temperature is above
50°F and no precipitation is falling. (2015 IECC R403.9 and C403.2.4.5)
- Automatic or manual controls installed for system shut off when outdoor temperature
is above 40°F. (2015 IECC R403.9 and C403.2.3.5)
- Inspection by testing hydrostatically at 1.5 times max system design pressure, but not
less than 100psi, for 15 minutes. (2015 IMC 1208.1)
Snow stops required where snow can
slide onto potentially occupied areas
such as walkways, parking areas, etc.
or do damage to property such as utility
meters - IBC 1513/COA 8.20.020(z).
Recessed luminaires installed
in building thermal envelope
shall be sealed and IC-rated
– IECC sec R402.4.5
Any recessed light fixtures
in contact with insulation
must be IC rated.
Electric vehicle charging (IRC 309.6).
Newly constructed one- or two-family dwellings and townhouses with a dedicated attached or
detached garage shall facilitate future installation and use of electric vehicle chargers. For each
dwelling unit, a 208/240-volt individual branch circuit or a listed raceway to accommodate a future
individual branch circuit shall be installed. The raceway shall not be less than trade size 1 (nominal
1-inch inside diameter). The raceway shall originate at the main service or subpanel and shall
terminate into a listed cabinet, box or other enclosure, and in close proximity to the proposed
location of the electric vehicle charger. Raceways are required to be continuous at enclosed,
inaccessible or concealed areas and spaces. The service panel or subpanel circuit directory shall
provide capacity to install a 40-ampere minimum dedicated branch circuit and space(s) reserved to
permit installation of a branch circuit overcurrent device. Electrical vehicle supply equipment shall be
installed in accordance with NFPA 70. 20
Exception: Additions and alterations to existing one- or two-family dwellings and townhomes
constructed per the IRC are exempt from this requirement.
SPECIAL INSPECTION REQUIRED:
-Structural steel welding: Field & Shop
-High strength bolting
-Epoxy anchors
-Intumescent paint
-Spray applied fire resistive materials
-Permanent micropiles
Special inspection is required per 2015 IBC
section 1704. Inspector to verify that copy of
agreement for inspection program to be on
the job site prior to performing any
inspections. A copy of all Special Inspector
field reports to be on the job site for
inspectors' review if requested. Failure to
comply may result in denial of inspection.
0037-2019-BRES
BMH Investments LTD
931 Gibson Ave
273707400004
Ice dam barrier consisting of 2 layers of underlayment
or a self-adhering polymer modified bitumen sheet shall
be used from eave edges to 6' within the exterior wall
line, 18" up from centerline of valleys, and 24" up any
vertical walls - COA amendment to IRC 905.2.7.1.
Ice dam barrier consisting of 2 layers of underlayment
or a self-adhering polymer modified bitumen sheet shall
be used from eave edges to 6' within the exterior wall
line, 18" up from centerline of valleys, and 24" up any
vertical walls - COA amendment to IRC 905.2.7.1.