Loading...
HomeMy WebLinkAboutFile Documents.1427 Crystal Lake Rd.0140-2020-BRES (14)The City of Aspen These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK 12/22/2020 03/03/2021 justinh Per this project’s asbestos inspection report, your project does not require a State asbestos abatement permit. However, the following OSHA regulation must be strictly adhered to: Standard Title 29, Part 1910.134, 1910.1001, and 1926.1101 of the Code of Federal Regulations. It is recommended that you familiarize yourself with these regulations and have a certified General Abatement Contractor (GAC) conduct the removal of the Asbestos Containing Material (ACM) under engineering controls and that once the removal process is completed, a visual inspection and clearance air monitoring be conducted by an independent, certified Air Monitoring Specialist. Furthermore, identified ACM may be in areas which were either not covered in the scope of the asbestos inspection or were inaccessible or hidden due to their application during the construction process and their subsequent enclosure or covering with building and finish materials. These areas should be inspected when renovation or demolition activities are scheduled which may disturb the materials within, or beneath these barriers. SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 degrees (0.52 rad) from vertical. 2111.10 Hearth and hearth extension. Masonry fireplace hearths and hearth extensions shall be constructed of concrete or masonry, supported by noncombustible materials, and reinforced to carry their own weight and all imposed loads. No combustible material shall remain against the underside of hearths or hearth extensions after construction. 2111.10.1 Hearth thickness. The minimum thickness of fireplace hearths shall be 4 inches (102 mm). 2111.10.2 Hearth extension thickness. The minimum thickness of hearth extensions shall be 2 inches (51 mm). Exception: When the bottom of the firebox opening is raised not less than 8 inches (203 mm) above the top of the hearth extension, a hearth extension of not less than 3/8-inch-thick (9.5 mm) brick, concrete, stone, tile or other approved noncombustible material is permitted. 2111.11 Hearth extension dimensions. Hearth extensions shall extend not less than 16 inches (406 mm) in front of, and not less than 8 inches (203 mm) beyond, each side of the fire- place opening. Where the fireplace opening is 6 square feet (0.557 m2) or larger, the hearth extension shall extend not less than 20 inches (508 mm) in front of, and not less than 12 inches (305 mm) beyond, each side of the fireplace opening. 2111.12 Fireplace clearance. Any portion of a masonry fire- place located in the interior of a building or within the exte- rior wall of a building shall have a clearance to combustibles of not less than 2 inches (51 mm) from the front faces and sides of masonry fireplaces and not less than 4 inches (102 mm) from the back faces of masonry fireplaces. The airspace shall not be filled, except to provide fireblocking in accor- dance with Section 2111.13. Exceptions: 1. Masonry fireplaces listed and labeled for use in con- tact with combustibles in accordance with UL 127 and installed in accordance with the manufacturer’s instructions are permitted to have combustible mate- rial in contact with their exterior surfaces. 2. When masonry fireplaces are constructed as part of masonry or concrete walls, combustible materials shall not be in contact with the masonry or concrete walls less than 12 inches (306 mm) from the inside surface of the nearest firebox lining. 3. Exposed combustible trim and the edges of sheath- ing materials, such as wood siding, flooring and dry- wall, are permitted to abut the masonry fireplace sidewalls and hearth extension, in accordance with Figure 2111.12, provided such combustible trim or sheathing is not less than 12 inches (306 mm) from the inside surface of the nearest firebox lining. 4. Exposed combustible mantels or trim is permitted to be placed directly on the masonry fireplace front surrounding the fireplace opening, provided such combustible materials shall not be placed within 6 inches (153 mm) of a fireplace opening. Combusti- ble material directly above and within 12 inches (305 mm) of the fireplace opening shall not project more than 1/8 inch (3.2 mm) for each 1-inch (25 mm) distance from such opening. Combustible materials located along the sides of the fireplace opening that project more than 11/2 inches (38 mm) from the face of the fireplace shall have an additional clearance equal to the projection. For SI: 1 inch = 25.4 mm FIGURE 2111.12 ILLUSTRATION OF EXCEPTION TO FIREPLACE CLEARANCE PROVISION Staggered Wood Stud 1 hour fire, STC 51 assembly from the Gypsum Manual (GA-600 Fire Resistance Design Manual): READ THIS OR FAIL YOUR INSPECTION! Furred & Dropped Ceilings, Soffits, and Walls 20015 IBC 803.13 This applies to the attachment of finishes or furring to any assemblies that are required to be either fire-rated or non-combustible and is separate from the fire-rated assembly requirement. Walls, Ceilings & Soffits: If furred 1 ¾ inches or less, do one of the following: 4.Fill spaces with Class A material. 5.Fill spaces with inorganic or non-combustible material. 6.Fire block 8 feet in all directions. Walls: If set out (furred) greater than 1 ¾ inches, do one of the following: 4.Use a Class A finish material (such as drywall). 5.Use non-combustible framing. 6.Protect both sides with fire sprinklers. Ceilings & Soffits: If dropped (furred) greater than 1 ¾ inches: Framing members, hangers, and other assembly members must be non-combustible. You may not use wood. In Type III and V construction only, you may use fire retardant treated wood or non-combustible framing. 2015 IBC 601 Fire Resistive Requirements for Type of Construction: ____ Primary Structural Frame: ____hr (columns, beams, girders, etc) Exterior Bearing Walls: ____hr Interior Bearing Walls: ____hr Floors/Ceilings: ____hr Roof : ____hr Unless noted otherwise for occupancy separation or fire separation distance. VA 1 1 1 1 1 0140-2020-BRES MISCHIEF IN THE MOUNTAINS LLC 1427 CRYSTAL LAKE RD 273718131005 03/03/2021 justinh 03/12/2021 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150