Loading...
HomeMy WebLinkAboutFile Documents.931 Gibson Ave.0037-2019-BRES (41)G:\city\building_dept\Aspen 2004 Checklists\fireplace registration .doc over City of Aspen and Pitkin County FIREPLACE & WOODSTOVE REGISTRATION *Required—Contact Assessors offices at 920-5160 Registration will not be accepted without a Parcel Id number List all devices in your home (2 are allowed per building, except for gas appliances) Note: If the number, type and location on this registration form do not match what is show on your plans or what is actually installed, your permit or Certificate of Occupancy will be denied. Type of Building (circle one): Reside ntial Other Type of device Room Existing New Make & Model Wood burning fireplace (select one) ?Site-built masonry ?Factory built insert: model number: _____________________ Gas log fireplace Custom built insert _____________________ Certified woodstove Gas fireplace appliance (attach spec sheet) If any devices are being removed, please describe here, i.e. “old woodstove removed from living room” ·__________________________________________________________________________________ ·__________________________________________________________________________________ ·__________________________________________________________________________________ _______________________________________________________ ____________________________ Signature of applicant Date *Parcel Id number:____ ____ ____ ____ -- ____ ____ ____ -- ____ ____ -- ____ ____ ____ Street Address:_________________________________________________________________________ Owners Name:_________________________________________________________________________ 2737 074 00 004 931 GIBSON AVE BMH INVESTMENTS LTD Guest Bedroom Suite Parlor & Living Room 2 1 Stellar Hearth Heat n Glo SL-3X Outdoor Patio and Solus - Halo 48 Low Match Lit and August 30, 2019 01/22/2020 G:\city\building_dept\Aspen 2004 Checklists\fireplace registration .doc over ASPEN/PITKIN COUNTY FIREPLACE AND WOODSTOVE REGULATIONS In order to keep our air as clean as possible, the elected officials of Aspen and Pitkin County have passed ordinances to regulate the number of fireplaces and woodstoves that can be installed in any building. Building permit applicants must file a fireplace/woodstove registration with the City of Aspen Building Department or the Pitkin County Building Department before the building permit is issued. Pitkin County is separated into 2 areas. One is the non attainment area, which includes the City of Aspen and the Metropolitan areas of the county, i.e. Mountain Valley, Red Mountain, Difficult Ca mpground, T Lazy 7 Ranch, and part of Starwood. The other is the attainment area which includes the less densely populated parts of the county, i.e. Brush Creek Village, Holland Hills and Old Snowmass. Decorative gas appliance: A device utilizing natural gas as a fuel gas designed to appear as a real fireplace with a 4 to 5 inch Class B vent or direct vent, fixed glass door and a firebox no deeper than 24 inches. Certified Woodstove: Colorado Phase III certified woodstove or a Phase II EPA certified woodstove. Gas log fireplace: Meet all codes for burning wood but are used with gas logs. They are not allowed in bedrooms. Aspen and Metropolitan Areas of Pitkin County in the non attainment area New buildings in the non attainment area may have either 2 gas log fireplace or 2 certified woodstoves or 1 each. They may also have an unlimited number of decorative gas appliances. Wood burning fireplaces cannot be installed, nor may coal be used as fuel. Remodeling or an addition to an existing home in the non attainment area ·If the building has 2 or more fireplaces, gas log fireplaces or woodstoves, they only devices you can add are decorative gas appliances. ·If the building has 1 fireplace, gas log fireplace or woodstove, you may add 1 gas log fireplace and an unlimited number of decorative gas appliances. ·If a building has more than 2 fireplaces, gas log fireplaces; if one is affected by the remodel it must be removed. ·If a building has only 1 or 2 fireplaces, woodstoves or gas log fireplaces, please keep in mind: o If you alter the firebox of a fireplace, it must be converted to gas logs or removed. o If a woodstove is moved, it must be removed or replaced with a department certified woodstove. Attainment Area in Pitkin County New residential buildings in this area may have one wood burning fireplace and one gas log or certified woodstove. If there is no fireplace, you may have either 2 gas log fireplaces or 2 certified woodstoves or 1 each. Buildings may also have an unlimited number of decorative gas appliances. Remodeling or an addition to an existing building in the attainment areas ·If the building has 2 or more fireplaces or woodstoves, the only devices you can add are decorative gas appliances. ·If you have 1 fireplace or woodstove, you may add 1 gas log or certified woodstove and an unlimited number of decorative gas appliances ·If a building has more than 2 fireplaces or woodstoves: if one is affected by a remodel, it must be removed ·If a building has on 1 or 2 fireplaces, woodstoves or gas log appliances, please keep in mind: o If a woodstove is moved, it must be removed or replaced with a department certified device. o If you alter the firebox of a fireplace, and already have another fireplace, it must be converted to gas log Non residential buildings (which include commercial buildings, restaurants, lodges, public buildings, and hotels) in the attainment area of Pitkin County are allowed to have gas appliances. 01/22/2020 Specifications Additional information can be found online at www.heatnglo.com MODEL HEIGHT FRONT WIDTH BACK WIDTH DEPTH VIEWING AREA Actual Framing Actual Framing Actual Framing Actual Framing Please consult the manufacturer’s installation manual for all details and requirements before making a final design layout decision. SL-3X Direct Vent Gas Fireplace MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH GLASS SIZE SL-3X Actual Framing Actual Framing Actual Framing Actual Framing 24-1/8 x 16333422-3/4 34 32-3/8 32-3/4 16-1/4 16-1/4 SL-3X Ø GAS LINE ACCESS 33[838] 28-1/8[714] 24-1/8[613] 16[406] 32-1/8[816] 3-1/2[89] 6-7/8[175] 21-3/8[543] 32-3/8[822] 34-1/2[876] 8[203] 8-3/4[222] 16-1/4[413] 1/2[13]22-3/4[578]11-3/8[289] 15-7/8[403] 6-5/8[168] 2-1/8[54] 6[152]1[25] 28[711] 5[127] 14[356] 9-1/8[232] ELECTRICALACCESS Ø Ø HEAT-ZONE® ACCESS Ø GAS LINE ACCESS 33[838] 28-1/8[714] 24-1/8[613] 16[406] 32-1/8[816] 3-1/2[89] 6-7/8[175] 21-3/8[543] 32-3/8[822] 34-1/2[876] 8[203] 8-3/4[222] 16-1/4[413] 1/2[13]22-3/4[578]11-3/8[289] 15-7/8[403] 6-5/8[168] 2-1/8[54] 6[152]1[25] 28[711] 5[127] 14[356] 9-1/8[232] ELECTRICALACCESS Ø Ø HEAT-ZONE® ACCESS 28 [711] 25-1/16 [637]26-3/4 [680] 2-5/8 [67] 1-5/8 [41] 28-3/4 [730] 1-1/8 [29] 27-5/16 [694] 29-3/8 [746] 29-1/16 [738] Firescreen Front Chateau and Halston Fronts 01/22/2020 Specifications GS/HNG/SL-3X_1016 PRODUCT LISTING CODES US ANSI Z21.88a-2007 CAN CSA 2.33a-M2007 UL307B Additional information can be found online at www.heatnglo.com Product information provided is not complete and is subject to change without notice. Product installation must adhere strictly to instructions accompanying product to avoid risk of fire and potential injury. Lakeville, MN Web: heatnglo.com Phone: 888-427-3973 AREA TO COMBUSTIBLES (in inches) CLEARANCE TO CEILING 32 COMBUSTIBLE/NON-COMBUSTIBLE FLOOR 0 BEHIND APPLIANCE 1/2 SIDES OF APPLIANCE 1/2 FRONT OF APPLIANCE 36 MINIMUM FIREPLACE CLEARANCES APPLIANCE LOCATION WALL PENETRATION MANTEL LEG/WALL PROJECTIONS K C A L I B G See Installsection 5.Dfor Alcoveinstallation J J G A F H M FRAMING DIMENSIONS CLEARANCES TO COMBUSTIBLES C B D A A Rough Opening (Width) B Rough Opening (Height) C Rough Opening (Depth) D Rough Opening (Width) DVP pipe SLP pipe DVP pipe SLP pipe in 10 8-5/8 32-3/4 16-1/4 16-1/4 34 mm 254 219 832 413 413 864 5 6 7 8 9 1034 5 12 1110 9 876 TOP OF HOOD 4 12 13 11 32 CEILING MANTEL PROJECTIONS SL-3X Model A B C E F G SL-3X in 39-1/2 34 55-7/8 1 1/2 44 mm 1003 864 1413 25 13 1117 H I J K L M SL-3X in 62-1/4 16-1/4 48-1/2 68-3/4 13-1/2 7-1/2 mm 1581 413 1232 1737 343 191 34-1/2"[876]21-3/8"[543] 35-1/2"[902]*22-3/8"[568]* 10" 10"10" 12" *Shows center of vent hole for top or rear venting. Center of hole is 1" above the center of the horizontal vent pipe. 3ft. maximum Top View 2-7/8" minimum 1/2" minimum Unlimited Top View 5-7/8" minimum 3" minimum Mantel Leg Projection (acceptable on both sides of opening) Wall Projection (acceptable on one side of opening) 32"[813] 1/2" [13] 1/2" [13] 0" 0"36" [915] Measure from top of unitopening or from top of hood 01/22/2020 Form Submission: Build your owr custorn fireplace I Stellar Hearth products Contact lnformation Name: Elizabeth Proctor Email: elizabeth@fandmarchitects.com Phone Number: 9z {-t987 2t 07 Company Name (optional): F&M Architects Project Name (optional): Beckerman House Address; PO Box 6762 15 Kearns Rd. Suite D Snowmass Viliage. CO 8'161 5 United States Appearance Type of lnterior: Traditional lnierior Glass: No Glass Notes: 952 -224.4A7 2 I info@stellarhearth"com 16873 Fish Point Rd SE Prior Lake, MN 55372 https :l/ww.w. stell arhearth. comientityfbnlri I Form Submission: Build your own custom fireplace Style / Dimensions Two-sided Corner-right width JO Height 36" Depth 36" Other Specs Type of Gas: Natu.al Gas Type of lnstallation: lndoor Electrical Access Point: Right Side Base Gas Access Point: Right Side Base Location Type: Residential Remodel or New Construction: Remodel Please provide an overview of the project and venting configuration, including any special considerations or requests.: I am working on a design for a historic remodel project in Aspen. CO. We would like an open right sided corner unit on the main level and a one sided unit above this piece on the bedroom level. We will need to use the historic chimney opening and our structural engineer is concerned with the weight of the fireplaces as we will have to keep the historic framing in place. lt seems like a custom corner steel box with a b-vent is what we will need to look at but I was hoping to go over the opl;ols you miqnt have lor th,s scenario. lof I 7i3t'2019.3:,15 Pl\4 01/22/2020 PROPOSAL TO: PROJECT NAME: PROPOSAL #: BECKERMAN HOU5E.22 SPECIFICATIONS AND INCLUSIONS;SINGLE sIDED - TRADITIONAL. OPEN HEARTH ULiULC certification or equivalent. The proposal includes shipping cost to a designated address' Fire feature will be designed per the blue prints with approx' 3'w x 3' H x 3' D' The fire feature will have an eiectronic safely valve' The fire feature will be open hearth with drop-down glass' The fire feature will use a '10" B-Vent flue pipe' The fire feature will use a provided powervent cap' The fire feature wilt use a provided mechanical exhaust damper' The fire feature will have a sound reduction chamber standard' The fire feature will use inside air for the air intake see required CFM below' The fire feature will have a traditionat interior with woodburning log set and electric ember bed standard NOT INCLUDED IN BID: The general contractor is responsible for all applicable permits' The generai contractor is responsible for the installation ofthe flue, fireplace, gas, and required electricily' Flashing and other supplies for roof penetration and powervent support, not included. .10" B-Vent flue pipe is required, Llut not included' Must be ULi ULC recognized REQUIRED: 1 20VAC, 5 AMP power to the fireplace location and the powervent on the roof 40,000 BTU capacity. Natural Gas - 7 0 lnches/Wc Flue pipe not to exceed 60' total length, with four elbows' Forrunsexceeding60',contactStellarHearthProductsdirectlyforapproval' 535 CFM of make-uP requrred. LEAD TIME DETAILS: This is a custom built flreplace and will require about 14 weeks from receiving the signed prints to complete' lnitial 5070 deposit is due following the acceptance of the proposal. Remaining 500/o is due at completion of proiect' Upon receipt of deposit, prints will be provided to clientwithin 3 working days' The 14-weeks to completion date begins upon stellar Hearth Producrs receiving the siSned and approved prints' we hereby propose to furnish the material in complete accordance with the above specifications, Fireplace:Available OPtions: Reflective Mirrors:u5DFireplace: pAyMENT TERMS: payment shall consist of soyo at time of purchase order and 50% at completion. Alt materidJ is guaronteed to be as specified. All work to be campleted in o warkrnonlike monner occordtng ta standord ptoctices' Any alterqtian or deviation fron the obove specificatians involving extra cost will be exeuted only upan written orders, and ttill become on extro chorge ovet ond beyond the estimctte. All agreefl.tents ore contingent upon accidents or clelays beyond are contro!. lnitial deposit is non'refundoble' This proposol is sLtbject to occeptonce within 30 doys and is void thereofter at the optiotl of Stellar Hearth Products' USD AuthorizedSignature: RobertSloan Date: 7l1Al2O19 01/22/2020 01 / 2 2 / 2 0 2 0 CLEARANCES to ADJACENT MATERIALS solus Fire Features UK & EUROPEAN SPECIFICATIONS Gas type: Natural Gas Propane/But. Gas press: G20 G30 Heat Out: G20/11.7 G30/22.5 EN 509:2000 EN 60335-1:2001 NORTH AMERICA SPECIFICATIONS Gas type: Natural Gas Propane/But. Gas press: 3.5" - 7.0" w.c. N/A BTU / kWh: 40,000/11.7 76,000/22.5 ANSI Z21.97-2014 CSA 2.41-2014 0558 HALO 48 LOW MATCH LIT NG & LP Fire is beautiful and also dangerous if not handled properly. Please have a qualified gas fitter setup and install this product ac- cording to local codes. This product has been tested and certified by Labtest Certification Inc. as being safe, as long as these minimum clearances to adjacent materials are maintained. FOR OUTDOOR USE ONLY JOB / ORDER Name or Number: Signature & Date: CONCRETE SPECS Strength: 10,000 psi (proprietary) Weight: Top- 420 lbs / 190 kg Bottom- 77 lbs / 35 kg FP.03 ALL WEATHER COVER SHALL BE PROVIDED BY THE GENERAL CONTRACTOR 01/22/2020