HomeMy WebLinkAboutFile Documents.931 Gibson Ave.0037-2019-BRES (41)G:\city\building_dept\Aspen 2004 Checklists\fireplace registration .doc
over
City of Aspen and Pitkin County
FIREPLACE & WOODSTOVE REGISTRATION
*Required—Contact Assessors offices at 920-5160
Registration will not be accepted without a Parcel Id number
List all devices in your home (2 are allowed per building, except for gas appliances)
Note: If the number, type and location on this registration form do not match what is show on your plans or what is actually
installed, your permit or Certificate of Occupancy will be denied.
Type of Building (circle one): Reside ntial Other
Type of device Room Existing New Make & Model
Wood burning fireplace (select one)
?Site-built masonry
?Factory built insert: model
number:
_____________________
Gas log fireplace Custom built insert
_____________________
Certified woodstove
Gas fireplace appliance
(attach spec sheet)
If any devices are being removed, please describe here, i.e. “old woodstove removed from living room”
·__________________________________________________________________________________
·__________________________________________________________________________________
·__________________________________________________________________________________
_______________________________________________________ ____________________________
Signature of applicant Date
*Parcel Id number:____ ____ ____ ____ -- ____ ____ ____ -- ____ ____ -- ____ ____ ____
Street Address:_________________________________________________________________________
Owners Name:_________________________________________________________________________
2737 074 00 004
931 GIBSON AVE
BMH INVESTMENTS LTD
Guest Bedroom Suite
Parlor & Living Room 2
1
Stellar Hearth
Heat n Glo
SL-3X
Outdoor Patio and Solus - Halo 48 Low Match Lit and
August 30, 2019
01/22/2020
G:\city\building_dept\Aspen 2004 Checklists\fireplace registration .doc
over
ASPEN/PITKIN COUNTY FIREPLACE AND WOODSTOVE REGULATIONS
In order to keep our air as clean as possible, the elected officials of Aspen and Pitkin County have passed ordinances to regulate the
number of fireplaces and woodstoves that can be installed in any building. Building permit applicants must file a
fireplace/woodstove registration with the City of Aspen Building Department or the Pitkin County Building Department before the
building permit is issued.
Pitkin County is separated into 2 areas. One is the non attainment area, which includes the City of Aspen and the Metropolitan
areas of the county, i.e. Mountain Valley, Red Mountain, Difficult Ca mpground, T Lazy 7 Ranch, and part of Starwood. The other
is the attainment area which includes the less densely populated parts of the county, i.e. Brush Creek Village, Holland Hills and
Old Snowmass.
Decorative gas appliance: A device utilizing natural gas as a fuel gas designed to appear as a real fireplace with a 4 to 5 inch Class
B vent or direct vent, fixed glass door and a firebox no deeper than 24 inches.
Certified Woodstove: Colorado Phase III certified woodstove or a Phase II EPA certified woodstove.
Gas log fireplace: Meet all codes for burning wood but are used with gas logs. They are not allowed in bedrooms.
Aspen and Metropolitan Areas of Pitkin County in the non attainment area
New buildings in the non attainment area may have either 2 gas log fireplace or 2 certified woodstoves or 1 each. They may also
have an unlimited number of decorative gas appliances. Wood burning fireplaces cannot be installed, nor may coal be used as fuel.
Remodeling or an addition to an existing home in the non attainment area
·If the building has 2 or more fireplaces, gas log fireplaces or woodstoves, they only devices you can add are decorative gas
appliances.
·If the building has 1 fireplace, gas log fireplace or woodstove, you may add 1 gas log fireplace and an unlimited number of
decorative gas appliances.
·If a building has more than 2 fireplaces, gas log fireplaces; if one is affected by the remodel it must be removed.
·If a building has only 1 or 2 fireplaces, woodstoves or gas log fireplaces, please keep in mind:
o If you alter the firebox of a fireplace, it must be converted to gas logs or removed.
o If a woodstove is moved, it must be removed or replaced with a department certified woodstove.
Attainment Area in Pitkin County
New residential buildings in this area may have one wood burning fireplace and one gas log or certified woodstove. If there is no
fireplace, you may have either 2 gas log fireplaces or 2 certified woodstoves or 1 each. Buildings may also have an unlimited
number of decorative gas appliances.
Remodeling or an addition to an existing building in the attainment areas
·If the building has 2 or more fireplaces or woodstoves, the only devices you can add are decorative gas appliances.
·If you have 1 fireplace or woodstove, you may add 1 gas log or certified woodstove and an unlimited number of decorative
gas appliances
·If a building has more than 2 fireplaces or woodstoves: if one is affected by a remodel, it must be removed
·If a building has on 1 or 2 fireplaces, woodstoves or gas log appliances, please keep in mind:
o If a woodstove is moved, it must be removed or replaced with a department certified device.
o If you alter the firebox of a fireplace, and already have another fireplace, it must be converted to gas log
Non residential buildings (which include commercial buildings, restaurants, lodges, public buildings, and hotels) in the attainment
area of Pitkin County are allowed to have gas appliances.
01/22/2020
Specifications
Additional information can be found online at www.heatnglo.com
MODEL HEIGHT FRONT WIDTH BACK WIDTH DEPTH VIEWING AREA
Actual Framing Actual Framing Actual Framing Actual Framing
Please consult the manufacturer’s
installation manual for all details and
requirements before making a final
design layout decision.
SL-3X
Direct Vent Gas Fireplace
MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH GLASS SIZE
SL-3X Actual Framing Actual Framing Actual Framing Actual Framing 24-1/8 x 16333422-3/4 34 32-3/8 32-3/4 16-1/4 16-1/4
SL-3X
Ø
GAS LINE ACCESS
33[838]
28-1/8[714]
24-1/8[613]
16[406]
32-1/8[816]
3-1/2[89]
6-7/8[175]
21-3/8[543]
32-3/8[822]
34-1/2[876]
8[203]
8-3/4[222]
16-1/4[413]
1/2[13]22-3/4[578]11-3/8[289]
15-7/8[403]
6-5/8[168]
2-1/8[54]
6[152]1[25]
28[711]
5[127]
14[356]
9-1/8[232]
ELECTRICALACCESS
Ø
Ø
HEAT-ZONE® ACCESS
Ø
GAS LINE ACCESS
33[838]
28-1/8[714]
24-1/8[613]
16[406]
32-1/8[816]
3-1/2[89]
6-7/8[175]
21-3/8[543]
32-3/8[822]
34-1/2[876]
8[203]
8-3/4[222]
16-1/4[413]
1/2[13]22-3/4[578]11-3/8[289]
15-7/8[403]
6-5/8[168]
2-1/8[54]
6[152]1[25]
28[711]
5[127]
14[356]
9-1/8[232]
ELECTRICALACCESS
Ø
Ø
HEAT-ZONE® ACCESS
28 [711]
25-1/16
[637]26-3/4
[680]
2-5/8
[67]
1-5/8
[41]
28-3/4
[730]
1-1/8
[29]
27-5/16
[694]
29-3/8 [746]
29-1/16 [738]
Firescreen Front Chateau and Halston Fronts 01/22/2020
Specifications
GS/HNG/SL-3X_1016
PRODUCT LISTING CODES
US ANSI Z21.88a-2007
CAN CSA 2.33a-M2007
UL307B
Additional information can be found online at www.heatnglo.com
Product information provided is
not complete and is subject to
change without notice. Product
installation must adhere strictly
to instructions accompanying
product to avoid risk of fire and
potential injury.
Lakeville, MN Web: heatnglo.com
Phone: 888-427-3973
AREA TO COMBUSTIBLES
(in inches)
CLEARANCE TO CEILING 32
COMBUSTIBLE/NON-COMBUSTIBLE FLOOR 0
BEHIND APPLIANCE 1/2
SIDES OF APPLIANCE 1/2
FRONT OF APPLIANCE 36
MINIMUM FIREPLACE CLEARANCES
APPLIANCE LOCATION
WALL PENETRATION
MANTEL LEG/WALL PROJECTIONS
K
C
A
L
I
B
G
See Installsection 5.Dfor Alcoveinstallation
J
J G
A
F
H
M
FRAMING DIMENSIONS
CLEARANCES TO COMBUSTIBLES
C
B
D
A
A
Rough Opening
(Width)
B
Rough Opening
(Height)
C
Rough Opening
(Depth)
D
Rough Opening
(Width)
DVP pipe SLP pipe DVP pipe SLP pipe
in 10 8-5/8 32-3/4 16-1/4 16-1/4 34
mm 254 219 832 413 413 864
5 6 7 8 9 1034
5
12
1110
9
876
TOP OF HOOD
4
12 13
11
32
CEILING
MANTEL PROJECTIONS
SL-3X
Model A B C E F G
SL-3X in 39-1/2 34 55-7/8 1 1/2 44
mm 1003 864 1413 25 13 1117
H I J K L M
SL-3X in 62-1/4 16-1/4 48-1/2 68-3/4 13-1/2 7-1/2
mm 1581 413 1232 1737 343 191
34-1/2"[876]21-3/8"[543]
35-1/2"[902]*22-3/8"[568]*
10"
10"10"
12"
*Shows center of vent hole for top
or rear venting. Center of hole is 1"
above the center of the horizontal
vent pipe.
3ft. maximum
Top View
2-7/8"
minimum
1/2"
minimum
Unlimited
Top View
5-7/8"
minimum
3"
minimum
Mantel Leg Projection
(acceptable on both sides of opening)
Wall Projection
(acceptable on one side of opening)
32"[813]
1/2" [13]
1/2" [13]
0"
0"36" [915]
Measure from top of unitopening or from top of hood
01/22/2020
Form Submission: Build your owr custorn fireplace I Stellar Hearth products
Contact lnformation
Name: Elizabeth Proctor
Email: elizabeth@fandmarchitects.com
Phone Number: 9z {-t987 2t 07
Company Name (optional): F&M Architects
Project Name (optional): Beckerman House
Address; PO Box 6762
15 Kearns Rd. Suite D
Snowmass Viliage. CO 8'161 5
United States
Appearance
Type of lnterior: Traditional lnierior
Glass: No Glass
Notes:
952 -224.4A7 2 I info@stellarhearth"com
16873 Fish Point Rd SE
Prior Lake, MN 55372
https :l/ww.w. stell arhearth. comientityfbnlri I
Form Submission: Build your own custom fireplace
Style / Dimensions
Two-sided
Corner-right
width
JO
Height
36"
Depth
36"
Other Specs
Type of Gas: Natu.al Gas
Type of lnstallation: lndoor
Electrical Access Point: Right Side Base
Gas Access Point: Right Side Base
Location Type: Residential
Remodel or New Construction: Remodel
Please provide an overview of the project and venting
configuration, including any special considerations or requests.:
I am working on a design for a historic remodel project in Aspen. CO.
We would like an open right sided corner unit on the main level and a
one sided unit above this piece on the bedroom level. We will need to
use the historic chimney opening and our structural engineer is
concerned with the weight of the fireplaces as we will have to keep the
historic framing in place. lt seems like a custom corner steel box with
a b-vent is what we will need to look at but I was hoping to go over the
opl;ols you miqnt have lor th,s scenario.
lof I 7i3t'2019.3:,15 Pl\4
01/22/2020
PROPOSAL TO:
PROJECT NAME:
PROPOSAL #:
BECKERMAN HOU5E.22
SPECIFICATIONS AND INCLUSIONS;SINGLE sIDED - TRADITIONAL. OPEN HEARTH
ULiULC certification or equivalent.
The proposal includes shipping cost to a designated address'
Fire feature will be designed per the blue prints with approx' 3'w x 3' H x 3' D'
The fire feature will have an eiectronic safely valve'
The fire feature will be open hearth with drop-down glass'
The fire feature will use a '10" B-Vent flue pipe'
The fire feature will use a provided powervent cap'
The fire feature wilt use a provided mechanical exhaust damper'
The fire feature will have a sound reduction chamber standard'
The fire feature will use inside air for the air intake see required CFM below'
The fire feature will have a traditionat interior with woodburning log set and electric ember bed standard
NOT INCLUDED IN BID:
The general contractor is responsible for all applicable permits'
The generai contractor is responsible for the installation ofthe flue, fireplace, gas, and required electricily'
Flashing and other supplies for roof penetration and powervent support, not included.
.10" B-Vent flue pipe is required, Llut not included' Must be ULi ULC recognized
REQUIRED:
1 20VAC, 5 AMP power to the fireplace location and the powervent on the roof
40,000 BTU capacity. Natural Gas - 7 0 lnches/Wc
Flue pipe not to exceed 60' total length, with four elbows'
Forrunsexceeding60',contactStellarHearthProductsdirectlyforapproval'
535 CFM of make-uP requrred.
LEAD TIME DETAILS:
This is a custom built flreplace and will require about 14 weeks from receiving the signed prints to complete'
lnitial 5070 deposit is due following the acceptance of the proposal. Remaining 500/o is due at completion of proiect'
Upon receipt of deposit, prints will be provided to clientwithin 3 working days'
The 14-weeks to completion date begins upon stellar Hearth Producrs receiving the siSned and approved prints'
we hereby propose to furnish the material in complete accordance with the above specifications,
Fireplace:Available OPtions:
Reflective Mirrors:u5DFireplace:
pAyMENT TERMS: payment shall consist of soyo at time of purchase order and 50% at completion.
Alt materidJ is guaronteed to be as specified. All work to be campleted in o warkrnonlike monner occordtng ta standord ptoctices'
Any alterqtian or deviation fron the obove specificatians involving extra cost will be exeuted only upan written orders, and ttill become on extro chorge ovet ond
beyond the estimctte. All agreefl.tents ore contingent upon accidents or clelays beyond are contro!. lnitial deposit is non'refundoble'
This proposol is sLtbject to occeptonce within 30 doys and is void thereofter at the optiotl of Stellar Hearth Products'
USD
AuthorizedSignature: RobertSloan Date: 7l1Al2O19
01/22/2020
01
/
2
2
/
2
0
2
0
CLEARANCES to ADJACENT MATERIALS
solus Fire Features
UK & EUROPEAN SPECIFICATIONS
Gas type: Natural Gas Propane/But.
Gas press: G20 G30
Heat Out: G20/11.7 G30/22.5
EN 509:2000
EN 60335-1:2001
NORTH AMERICA SPECIFICATIONS
Gas type: Natural Gas Propane/But.
Gas press: 3.5" - 7.0" w.c. N/A
BTU / kWh: 40,000/11.7 76,000/22.5
ANSI Z21.97-2014
CSA 2.41-2014
0558
HALO 48 LOW
MATCH LIT NG & LP
Fire is beautiful and also dangerous if not
handled properly. Please have a qualified
gas fitter setup and install this product ac-
cording to local codes.
This product has been tested and certified
by Labtest Certification Inc. as being safe,
as long as these minimum clearances to
adjacent materials are maintained.
FOR OUTDOOR USE ONLY
JOB / ORDER
Name or Number:
Signature & Date:
CONCRETE SPECS
Strength: 10,000 psi (proprietary)
Weight: Top- 420 lbs / 190 kg
Bottom- 77 lbs / 35 kg
FP.03
ALL WEATHER COVER SHALL BE PROVIDED BY THE GENERAL
CONTRACTOR
01/22/2020