Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.931 Gibson Ave.0037-2019-BRES (58)
2/3/2020 ROOFING SYSTEMS | UL Product iQ https://iq.ulprospector.com/en/profile?e=148913 1/4 TGFU.R10689 - ROOFING SYSTEMS Roofing Systems See General Information for Roofing Systems GAF R10689 1 CAMPUS DR PARSIPPANY, NJ 07054 USA Any UL Classified peel and stick underlayment may be used in conjunction with "VersaShield® Fire-Resistant Roof Deck Protection" and "VersaShield® Underlayment" in any of the following systems. OTHER SYSTEMS Class A 1. Deck: C-15/32 or spaced sheathing Incline: Unlimited Underlayment: — One ply "VersaShield® Fire-Resistant Roof Deck Protection" or "VersaShield® Underlayment" mechanically fastened. Ply Sheet: — One ply Type 30 base sheet or "VersaShield® Fire-Resistant Roof Deck Protection" or "VersaShield® Underlayment" mechanically fastened. Shingles or Panels: — UL Classified or Listed Steel or copper. 2. Deck: C-15/32 Incline: Unlimited Underlayment: — One ply "VersaShield® Fire-Resistant Roof Deck Protection" or "VersaShield® Underlayment" mechanically fastened. Shingles: — UL Listed GAF Class A asphalt glass fiber shingle. 3. Deck: C-15/32 Incline: Unlimited Underlayment: — Two plies "VersaShield® Fire-Resistant Roof Deck Protection" or "VersaShield® Underlayment." Shingles or Panels: — UL Classified or Listed Aluminum. 4. Deck: C-15/32 Incline: Unlimited Underlayment: — Three plies "VersaShield® Fire-Resistant Roof Deck Protection" or "VersaShield® Underlayment." Membrane: — Endur -All "Cedar-shake." 5. Deck: C-15/32 or Spaced Sheathing Incline: Unlimited Underlayment: — One or more plies "VersaShield® Fire-Resistant Roof Deck Protection" or "VersaShield® Underlayment" mechanically fastened. Panels: — Any UL Listed or Classified standing seam steel, steel or copper. 6. Deck: C-15/32 or Spaced Sheathing Incline: Unlimited Underlayment: — One ply "VersaShield® Fire-Resistant Roof Deck Protection" or "VersaShield® Underlayment" mechanically fastened. Shingles: — UL Listed stone coated, direct to deck, non-batten systems. 7. Deck: C-15/32 or Spaced Sheathing Incline: Unlimited Underlayment: — One or more plies "VersaShield® Fire-Resistant Roof Deck Protection" or "Versashield® Underlayment" mechanically fastened. 2/3/2020 ROOFING SYSTEMS | UL Product iQ https://iq.ulprospector.com/en/profile?e=148913 2/4 Roof Panels: — Steel panels, fastened to 2 x 2 wood battens 8. Deck: C-15/32 Incline: Unlimited Underlayment: — One or more plies "VersaShield® Fire-Resistant Roof Deck Protection" or "Versashield® Underlayment" mechanically fastened. Shingles: — UL Listed GAF Class A asphalt glass fiber shingle. 9. Deck: C-15/32 Incline: Unlimited See Note Underlayment: — One or more plies "WeatherWatch®" or "StormGuard®", self-adhered. Slip Sheet: — One or more plies "VersaShield® SOLO™ Fire-Resistant Slip Sheet", mechanically fastened. Surfacing: — Any GAF Building Integrated Photovoltaic (BIPV) system, mechanically fastened. Note - System is to be installed with UL Certified GAF Solar Rack/Module Building Integrated Photovoltaic (BIPV) Systems ONLY and not utilized as a stand-alone system. Slope is determined by the requirements of the BIPV solar rack/module being utilized with the roof covering system. 10. Deck: C-15/32 or spaced sheathing Incline: Unlimited Underlayment: — One or more plies "WeatherWatch®" or "StormGuard®", mechanically fastened. Slip Sheet: — One ply "VersaShield® Fire-Resistant Roof Deck Protection" or "VersaShield® Solo™ Fire-Resistant Slip Sheet", mechanically fastened. Shingles or Panels: — UL Classified or Listed Steel or copper. Class B 1. Deck: C-15/32 Incline: Unlimited Underlayment: — One ply "VersaShield® Fire-Resistant Roof Deck Protection" or "VersaShield® Underlayment" mechanically fastened. Shingles: — Any UL Classified or Listed steel, copper, aluminum. 2. Deck: Spaced Sheathing Incline: Unlimited Underlayment: — One ply "VersaShield® Fire-Resistant Roof Deck Protection" or "VersaShield® Underlayment." Shingles or Roof Panels: — UL Classified or Listed Steel or copper. SINGLE PLY MEMBRANE SYSTEMS Class A - Fully Adhered 1 . Deck: C-15/32 Incline: 1-1/2 Slip Sheet: — Two plies "VersaShield® Fire-Resistant Roof Deck Protection" or "VersaShield® Underlayment." Membrane: — Any UL Classified GAF membrane except TPO (Actual incline is determined by the maximum existing GAF membrane Classification incline, but cannot exceed 1-1/2:12). 2. Deck: C-15/32 Incline: 2 Slip Sheet: — Two plies "VersaShield® Fire-Resistant Roof Deck Protection" or "VersaShield® Underlayment." Membrane: — Any UL Classified GAF PVC membrane, fully adhered. 3. Deck: C-15/32 Incline: 2 Slip Sheet: — Two plies "VersaShield® Fire-Resistant Roof Deck Protection" or "VersaShield® Underlayment." Insulation: — Any UL Classified, any thickness (except EPS). Membrane: — Any UL Classified GAF membrane except TPO (if insulation is used, membrane must be currently UL Classified for use over it. Actual incline is determined by the existing GAF membrane/insulation Classification, but cannot exceed 2:12). Class B - Fully Adhered 1. Deck: C-15/32 Incline: 2 Slip Sheet: — One ply "VersaShield® Fire-Resistant Roof Deck Protection" or "VersaShield® Underlayment." Membrane: — Duro-Last Inc. "Duro-Last" (PVC), fully adhered. 2/3/2020 ROOFING SYSTEMS | UL Product iQ https://iq.ulprospector.com/en/profile?e=148913 3/4 2. Deck: C-15/32 Incline: 1-1/2 Slip Sheet: — One ply "VersaShield® Fire-Resistant Roof Deck Protection" or "VersaShield® Underlayment." Membrane: — Any UL Classified GAF membrane, except TPO. Actual incline is determined by the maximum existing GAF membrane Classification incline, but cannot exceed 1-1/2:12. Class A - Mechanically Fastened 1. Deck: C-15/32 Incline: 1-1/2 Slip Sheet: — Two plies "VersaShield® Fire-Resistant Roof Deck Protection" or "VersaShield® Underlayment" Membrane: — Any UL Classified GAF membrane (Actual incline is determined by the maximum existing GAF membrane Classification incline, but cannot exceed 1-1/2:12). 2. Deck: C-15/32 Incline: 2 Slip Sheet: — Two plies "VersaShield® Fire-Resistant Roof Deck Protection" or "VersaShield® Underlayment." Membrane: — Any Classified GAF PVC membrane, mechanically fastened. 3. Deck: C-15/32 Incline: 2 Slip Sheet: — Two plies "VersaShield® Fire-Resistant Roof Deck Protection" or "VersaShield® Underlayment." Insulation: — Any UL Classified, any thickness (except EPS). Membrane: — Any UL Classified GAF membrane (if insulation is used, membrane must be currently Classified for use over it. Actual incline is determined by the existing GAF membrane/insulation Classification, but cannot exceed an incline of 2:12). Class B - Mechanically Fastened 1. Deck: C-15/32 Incline: 2 Slip Sheet: — One ply "VersaShield® Fire-Resistant Roof Deck Protection" or "VersaShield® Underlayment." Membrane: — Duro-Last Inc. "Duro-Last" (PVC), mechanically fastened. 2. Deck: C-15/32 Incline: 1-1/2 Slip Sheet: — One ply "VersaShield® Fire-Resistant Roof Deck Protection" or "VersaShield® Underlayment." Membrane: — Any UL Classified GAF membrane. Actual incline is determined by the maximum existing GAF membrane Classification incline, but cannot exceed 1-1/2:12. MAINTENANCE AND REPAIR Class A 1. Deck: C-15/32 Incline: Unlimited Existing Roof System: — Any UL Listed Class A shingle. Slip Sheet: — One ply "VersaShield® Fire-Resistant Roof Deck Protection" or "VersaShield® Underlayment" mechanically fastened. Shingles: — Any UL Listed steel, copper, aluminum or GAF Class A asphalt glass fiber shingles. 2. Deck: C-15/32 Incline: Unlimited Existing Roof System: — Any Class A, B or C shingle. Slip Sheet: — One ply "VersaShield® Fire-Resistant Roof Deck Protection" or "VersaShield® Underlayment" mechanically fastened. Shingles: — UL Listed GAF Class A asphalt glass fiber shingles. 3. Deck: Slats spaced 1-1/2 in.Incline: Unlimited Existing Roof System: — Existing wood shake roof. Slip Sheet: — Two or more plies "VersaShield® Fire-Resistant Roof Deck Protection" or "VersaShield® Underlayment" mechanically fastened. Shingles: — Any UL Listed steel, copper or GAF Class A asphalt glass fiber shingle. Class B 2/3/2020 ROOFING SYSTEMS | UL Product iQ https://iq.ulprospector.com/en/profile?e=148913 4/4 1. Deck: Slats spaced 1-1/2 in.Incline: Unlimited Existing Roof System: — Existing wood shake roof to retain existing Listing. Slip Sheet: — One or more plies "VersaShield® Fire-Resistant Roof Deck Protection" or "VersaShield® Underlayment" mechanically fastened. Shingles: — Any UL Listed steel, copper, aluminum or GAF Class A asphalt glass fiber shingles. Class A, B or C 1. Deck: C-15/32 Incline: 1-1/2, see Note 1 Existing Roof System: — Any Class A, B or C built-up roof system. Slip Sheet: — One ply "VersaShield® Fire-Resistant Roof Deck Protection" or "VersaShield® Underlayment" mechanically fastened. Roof Covering: — Any GAF BUR system or CPE, CSM, CSPE, EPDM, NBP, PIB, GAF PVC membrane, GAF TPO membrane or TRE membrane system. Note 1: Classification (A, B or C) and maximum incline will be the same as that of the GAF Classified Roof Covering System (TGFU) currently limited to noncombustible roof deck, but not to exceed 1-1/2 in. slope. Last Updated on 2018-06-08 The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow- Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non- misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2020 UL LLC"