HomeMy WebLinkAboutFile Documents.1440 Crystal Lake Rd.0102-2022-BRES (9) a
Or
T/-, H®
This framing guide is a not exhaustive
reference for and typical Corner ment thorough
1= installation. This list is not and does not supplement thorough
review of the installation manual.
Corner (RS/LS) Series Framing
Combustible Framing Non-Combustible Framing
III °,
1111111111
IIII Il�lr� \� ��/—
°I� Ill �Il�u►,o., II \ II //
\ \\ �Q• Framing
\\\0\\
�\ ,\ � \i�;, \ \\\. �z % pp, Non-Combustible
min
\ 3 \� \' ' \ ? \ \\ 518"T X \ kt.� e:y.
\\�: \ \ e`v � \.. \ 1‘,',''
\$8 \�, i :\\ �� ���'N ` i\��:�x\S • \\�, 518"TyPeX
�\\ \ \ � \\\\ \
\ \ \ \\ � ' ` / . � �
•
g\ \\ II Non-Combustible \<\. \s2 \ Framing ,,`N,v- \ _\
B ��
,C B
,C
Dimension A: Rough Combustible Framing Opening Height
Dimension B: Rough Framing Opening Width Dimension A: Rough Framing Opening Height
Dimension C: Framing Depth Dimension B: Rough Framing Opening Width
Dimension D: Firestop Opening Dimension C Framing Depth
Dimension E: Non-combustible Framing Zone I Dimension D: Firestop Opening
A
WARNING—MAINTAIN AIR FLOW CLEARANCE:Firebox top vent must have minimum 4"of clearance to any material
achieve sufficient airflow. Failure to do so could result in improper fireplace operation, property damage, or physical
injury.
Model Framing Dimension A Dimension B Dimension C Dimension D Dimension E
Combustible 55 3/8" 14 1/8"
40H70 RS/LS 24 1/4" 18 3/8"
Non-Combustible 413/8" N/A
Combustible - 46 3/4" 13 1/4"
75 RS/LS - 35 1/4" 20 1/8"
Non-Combustible 33 1/2" N/A
110 RS/LS Combustible - 43 5/8" 50 3/4" 20 5/8° 12 1/2
Wilderness 44 RS/LS Non-Combustible - 31 1/8" N/A
110H RS/LS Combustible -- 49 1/2" 51" 22 1/4" 12 5/8
Non-Combustible 36 7/8" N/A
130 RS/LS Combustible 43 5/8" 12 1/2"
Wilderness 51 RS/LS 1 57 3/s 20 5/a
Non-Combustible 31 /8" N/A
Combustible 49 1/2" 12 5/8"
130H RS/LS 57 5/8" 22 1/4"
Non-Combustible 36 7/8" N/A
150 RS/LS Combustible 43 5/8" 67 1/4" 20 5/8" Refer to pipe 12 1/2"
Wilderness 60 RS/LS Non-Combustible 31 1/8" manufacturer's N/A
Combustible 49 1/2" firestop 12 5/8"
150H RS/LS 67 1/2" 22 1/4" dimensions
Non-Combustible 36 7/8" N/A
Combustible 43 5/8" 12 1/2"
170 RS/LS 75 1/8" 20 5/8"
Non-Combustible 31 1/8" N/A
Combustible 49 1/2" 12 5/8"
170H RS/LS 75 3/8" 22 1/4"
Non-Combustible 36 7/8" N/A
Combustible 43 5/8" 12 1/2"
200 RS/LS - 84 5/8" 20 5/8"
Non-Combustible 311/8" N/A
Combustible 49 1/2" 12 5/8"
200H RS/LS 84 7/8" 22 1/4"
Non-Combustible 36 7/8" N/A
Combustible 43 5/8" 12 1/2"
250 RS/LS 104 1/4" � 20 5/8"
Non-Combustible 311/8" RELIVED
250H RS/LS Combustible 49 36 '�$„ 104 1/2" 22 1/4" /
Non Combustible 09/ 1/2022
age 1 of 8
ASPEN
BUILDING DEPARTMENT
Building Around the Fireplace
Building Checklist
The following building checklist is a quick reference for a typical Ortal Built-In Series fireplace installation.
This list is not exhaustive and does not supplement thorough review of the installation manual.
RI Fireplace Location: Ensure the location allows for min. 36" clearance from viewing area to
combustibles and 12" to non-combustibles. Make sure a clear path is established to allow the fireplace
to be safely transported to installation location.
RI Venting: Confirm vent size (either 4"x6" or 5"x8" for natural vent and 3"x5" for power vent), vent
clearance (1" on sides and bottom, 3" on top), vent configuration, and termination location.
RI Height from Floor: Fireplace leg height is 9 13/16" (to bottom viewing area). Legs cannot be
removed/altered. If desired viewing area location on the wall is higher than 9 13/16", a platform can be
built for the fireplace to stand on.
RI Chase Floor/Platform: Fireplace can stand on the chase floor or a platform. Floor or platform must be
able to bear the weight of the fireplace. It can be constructed out of wood, concrete, metal, or any other
solid materials (not required to be non-combustible).
RI Chase Construction: No materials can be attached directly to the fireplace (exception: 5/8" Type X
Drywall). The area of the chase interior must meet minimum chase area requirements (depending on
the model). All chases require a heat release, and double glass fireplaces require and air intake (details
below).
O Framing: Adhere to minimum framing dimensions (or greater). Keep min. 2" clearance from back and
sides (as applicable by model) of fireplace to any material. The first 18" above the top of the fireplace
viewing area must always be non-combustible framing. Maintain min. 1/4" clearance from front face of
fireplace and front metal off-set to the framing. Maintain min. 4" space between air vents at top of
fireplace to any material. For recessed fireplaces, do not exceed 12" max. front overhang depth limit.
Side overhang depth is unlimited. No material is permitted to extend past the metal lip surrounding the
fireplace viewing area to allow for glass removal.
O 5/8" Type X Drywall Requirements: One layer of 5/8" Type X Drywall (or equivalent) must be installed
on the exterior of the chase framing.
O TV/Artwork: TV/Art must be min. 12" above top of fireplace viewing area.
RI Gas Supply Line and Power Location: Locate gas line with manual shut off according to local code.
Power provided by single gang 120V outlet in same area as gas line.
El Access Panel: Access panel highly recommended to access gas and electrical components for
servicing. Depending on the model, access panel can be placed at side or back of the fireplace within
3' of the pilot. Access panel or some other form of clear access to the chase is required for power-
vented fireplaces. Size recommendation: as large as possible depending on application. Min.
recommended size 10"x10".
El Heat Release: Crucial for Cool Wall Technology. Must start within 6" (max.) from the chase's ceiling.
Heat release must meet minimum size (depending on the model) of net free air space. Height of the
heat release must not exceed 1/3 of the width.
El Air Intake: Only required for double glass heat barrier. Must be located at or below level of double glass
fans. Air intake must meet minimum size (depending on the model) of net free air space.
RI Finishing: For finishes flush to the fireplace, no clearances are required. For finishes where the
fireplace is recessed to the finish, maintain 1/8" from the finish to the front face of the fireplace.
RECEIVE ,
09/D1/2022
age 2(of 8
ASPEN
BUILDING DEPARTMENT
Framing
Fireplace chase may be framed with either combustible (typically wood studs) or non-combustible framing (typically metal studs).
Any framing within 18 inches from the top of the fireplace glass(viewing area)must be non-combustible.This does not apply
to the framing to the back or side(s)of the fireplace;these may be combustible.
The fireplace is non-load bearing.The framing of the fireplace chase must be designed to carry the entire weight of the wall and finish
material.Surrounding material must not transfer weight to the fireplace(exception:5/8"Type X drywall or equivalent),or be connected
in any way to the fireplace.
No material is permitted to extend past the metal lip surrounding the fireplace viewing area.This area must be unobstructed
to allow the heat barrier and inside glass panel to be removable.
IMPORTANT: To ensure the glass is removable after installation, Magnetic Screw (Part#M03) under the fireplace lip
must be secured tightly to the firebox and screwed in as far as possible prior to installation of framing and finish material.
If the magnet is not completely screwed down into the firebox,the lip will sit ajar to the firebox, preventing glass removal.
5/8" Type X Drywall Requirements
Exterior side (i.e., room-facing side) of the framing must be
covered with 5/8"Type X Drywall (or equivalent). Finish material l,I _
is installed on top of the drywall.This applies to combustible and .�j
non-combustible framing. �111 �1��
Drywall is not required on the exterior portion of an insulated �;� Combustible
outside-facingwall. ,`�� ���� Framing
5 Non \� \\ 0111
/8" Type X Drywall may rest on the metal lip surrounding the Combustible - , k� ��
opening of the fireplace. Drywall must not be attached to the Framing \\\ ; \ , \� ;5'a Type X
fireplace as heat transfer from attaching materials (such as „\ Drywall
screws)can cause the drywall to crack. �\y�� vA
No material is permitted to extend past the metal lip �` � ��
surrounding the fireplace viewing area. This area must be �������
unobstructed to allow the heat barrier and inside glass ��
panel to be removable.
Chase Floor/Platform
The fireplace must be installed on a flat,solid,continuous surface. Surface
can be wood, concrete, metal, and other typical solid floor types. Surface ••• •• '
material is not required to be non-combustible. , g "e ® a" 1
•
Fireplace leg height is 9 13/16" (measured to bottom of viewing area). Legs
cannot be removed, cut,or adjusted. •
Raised Platform Option:To raise the fireplace higher than 9 13/16"height, ,
build a platform for the fireplace to stand on. Platform must be stable and • o a o 3E o ei 0 0 0 _ CD
,—+
able to bear the full weight of the fireplace. Platform can be constructed out - ,
of wood, concrete, metal, or any other solid materials. Platform material is ` t
not required to be non-combustible. _ a)
Fireplace Leg Height
NOTE: For fireplaces with the double glass heat barrier, an air intake might be necessary to incorporate into the
platform depending on the design. See"Air Intake for a Platform"for details.
Hearth Extension
A hearth extension is not required. Any hearth extension used is for appearance only and does not have to conform to a standard
hearth extension installation requirement.
RECEIVED
09/p1/2022
age 3 of 8
ASPEN
BUILDING DEPARTMENT
General Clearances
Viewing Area Clearances
The viewing area clearance zone is an area that extends perpendicular from the fireplace viewing area. The depth of the viewing
area clearance zone depends on the combustibility of the material in question. Distance is measured from the fireplace heat barrier.
Non-Combustible Materials Must be minimum 12 inches from fireplace viewing area.
Combustible Materials Must be minimum 36 inches from fireplace viewing area.
Materials(including combustible flooring and combustible finish material)are permitted below and around the viewing area clearance
zone.
Corner: Left Side Corner: Ride Side
g..-:
Rr, 041111104,
2r#H"7--' -I.i li - ,&.14.1 4. ...‘.,..t.
v.,"...000'••,..",,,,-zie,,:_ ,,,-"--' 0,44 ..„, '--.46‘.4°. , .?. 36.-4,
-5.;,-- , io
,,,, ,, ,,,,,,,
1-4° .004 ,.1°°' 1°I %
oe
Pe Ak( - • %1 •
1141144 'ill
Firebox Clearance
Maintain a 2-inch clearance from the back and/or side of the fireplace(depending on the model)to any material.
Corner: Left Side Corner: Ride Side
c c
E 2"min 2"min E
N '' (V
r AV Air ' < / /./ z!
0. 71,-i ir
1 Illi *C3*(47)..)'0* 1 / 'Os 0'Os 1
Clearance to Chase Ceiling
Maintain a 12-inch clearance from the top of the fireplace viewing area to the lowest point of the ceiling or to any building materials.
•
Keep area clear
from obstruction for
air circulation Heat Release must be on top or
within 6"of chase ceiling.
IkkilL
Non-combustible
framing&finish
II! idAIiMin
N III III
iIEI•InI!i
simii
NOTES:
• A heat release is required for every installation, but it is not required to be split between the two sides oft F.
in the diagram above. It is shown in this diagram for illustrative purposes only.See the"Heat Release Re t.,rtelv
of the installation manual for details.
• Clearance around the vent pipe must be maintained (1"clearance on the sides and bottom, 3"on top).
09/D1/2022
age4of8
ASPEN
BUILDING DEPARTMENT
Air Flow Clearance
A 4-inch clearance from the heat barrier vent openings along the top of the fireplace is required. Framing and building material is
NOT permitted in this area. Doing so will block the vents and cause the entire surrounding to overheat.
A
, ri N Heat Barrier Vents
, A
♦ \.
\ .
r Z
I ill \ \
►�7I
I
I .I I
r
ill
%t . B o
i r
I
111111A
NOTE: It is acceptable if the flat stud immediately above the fireplace hangs over heat barrier vents slightly when using
standard metal framing (as shown in diagram above).
Framing Clearance
Maintain a minimum 1/4 inches of space between the framing and the face of the fireplace.
.p - - - .
•
r .
, •, \
, A .,
• �.
1 • \ `.
‘ .
r
1 j
r' I
11
4 "MIN Mg1
► me o r
o o / ::1
. r
II Mr
/ RECEIVE ,
09/pe/5 022
ASPEN
N
BUILDING DEPARTMENT
Clearance to a Side Wall
The fireplace viewing area is zero-clearance to a side wall.A side wall is defined as a wall that meets the viewing area at a 90° angle.
, 9 1'�// A
1= Eill No Max
:G J� jl= �� ,I
x
co
0
Z
ir
Corner Side Walls(Top View)
111= Building Material
The temperature on the side wall can get as high as 150°F above ambient temperature. While the fireplace certification allows for
this temperature variance, building and finish materials will have their own limitations. Consult the material manufacturer to ensure
the material can safety withstand this temperature range.
This information does not apply to a wall that is constructed in front of the viewing area. For materials that will be in front of a main or
side viewing area, please refer to the"Viewing Area Clearances"section.
Maximum Overhang Depth
Overhang depth of a recessed fireplace must not exceed the clearances shown in the diagram below. Overhang depth is measured
from the edge of the fireplace lip to the out-most part of the wall (including finish material).
Bottom recess (or"hearth extension") has no minimum or maximum depth requirement. If bottom recess depth exceeds 12 inches,
ensure the structure is capable of supporting the weight of a fireplace technician for servicing.
Front (Long Side) Overhang di Side (Short Side) Overhang
MI
I _
12" MAX
. .
NO MAX it
m o Max
r-4-: I vi .4N - o ax
i ///// ///
RECEIVED
09/p1e/6 o2f0228 ag
ASPEN
BUILDING DEPARTMENT
Heat Release
A heat release is an opening in the fireplace chase that allows the heat inside the chase to passively circulate into an interior room.
This heat is generated convectively as the fireplace heats up. It is separate from exhaust heat produced at the combustion chamber
of the fireplace. For safety purposes, a heat release is required to keep the wall around the fireplace cool.
Heat Release Requirements
• The heat release must be located at or near the top of the fireplace chase and start within 6 inches(0-6 inches max)of the
chase ceiling/firestop. It can start at the chase ceiling. It can be located on the front, sides or back of the chase. It can be
released into any interior space that shares a wall with the chase.
• Minimum heat release size requirement depends on heat release orientation:
Fireplace Horizontal Heat Release Vertical Heat Release
Series
40-130* Minimum 124 sq. in. of free air space Minimum 160 sq. in. of free air space
150-200 Minimum 200 sq. in. of free air space Minimum 260 sq. in. of free air space
250 Minimum 250 sq. in. of free air space Minimum 325 sq. in. of free air space
*Includes Built-In Curve&Island fireplaces.Heat release requirements do not apply to Stand-alone Curve&stand-
alone Island fireplaces.
• For horizontal heat releases only, the height of the heat release must not exceed 1/3 of the width. (This does not apply to
vertical heat releases.)
• The space the heat release vents into must have a minimum volume of 184 ft3.
• The heat release can be in the form of(but not limited to)a louvered ventilation grille, gap, or reveal.
• For louvered/perforated ventilation grilles, the net free air space allowed in the louvered area must be equal or
greater than the minimum number of square inches required per fireplace.
• The interior area of the narrowest part of the fireplace chase(in square inches)must never be less than your required heat
release size (see"Chase Area Minimum"section of the installation manual for details).
• The heat release cannot be vented outdoors or to an unconditioned space.
NOTE: An angled heat release is not permitted.
The following diagrams are examples of potential heat release options. These drawings serve as illustrative purposes only.
Horizontal Heat Release
A • 7 A �
Heat
Release 6"Max
limi
Heat Release omi
IIMI
il
Air Flow I
liAir Flow El
Mitt Y
AIlird
4
Reveal Heat Release Louvered Grille Heat Release
RECEIVED
09/p1e/7 of 8022
ag
ASPEN
BUILDING DEPARTMENT
Air Intake
When installing a fireplace with a double glass heat barrier, it is essential to maintain cool air flow between the double glass panels.
For this purpose, an opening must be provided toward the bottom of the wall to allow the double glass fans to circulate room air
through the glass panels and up into the chase.This opening, called an air intake, needs to be made before closing the wall surface
below the fireplace.Air intake must meet the minimum size requirement.
Fireplace Series Air Intake
40-130* Minimum 124 sq. in. of free air space
150-200 Minimum 200 sq. in. of free air space
250 Minimum 250 sq. in. of free air space
*Includes Built-In Curve&Island fireplaces.Stand alone Curve&Island
fireplaces have an air intake already built into the base.
The air intake can be in the form of a louvered/perforated ventilation grille, gap, or toe-kick (reveal). For louvered ventilation grilles,
the net free air space allowed in the louvered area must be equal or greater than the minimum number of square inches required per
fireplace.
The entire air intake must be located at or below the level of the double glass fans.The air intake is not required to be on the
front wall of the fireplace. The air intake cannot be on a wall that allows air from outside the house directly into the fireplace chase.
Air must be from a conditioned space.
r WW \ / �K4I1��.i o
6 II v �► oI
1` I � �
I �iM
- /
0�
Air intake opening must
allow for minimum
Air Intake as Louvered Grille square inches of air Air Intake as Toe-kick
space specified in table
above.
Access Panel
An access panel is not required (see notes below for exception), but it is highly recommended. It allows for access to the fireplace's
gas and electrical components for servicing.
NOTE: An access panel, or some other form of clear access, is required for power vented fireplaces. For servicing
purposes, the power vent control box (located at the fireplace) must be easily accessible in a way that does not require
removal of the fireplace glass.
Access Panel Size and Location Recommendations:
• Minimum of 10 inches x 10 inches in size
• Located within 36 inches of the pilot to the side or back of the fireplace(see"Routing the Gas Line")
The size and location of the access panel may vary, but in all cases, it must allow the technician to comfortably access and service
the fireplace's gas and electrical components. These components are attached to the pilot on a flexible gas line and can be moved
within 36 inches of the pilot(located at the center front of the burner).
For ease of access, move the fireplace's gas and electrical components as close to the access panel as possible. If there is any
distance between the access panel and the gas and electrical components, the access panel size must be increased
accordingly. Prior to installation, fireplace dealers/installers should work with the owner, builder, project architects and/or interior
designers to determine the best size and location of their access panel.
If an access panel cannot be incorporated, the alternative method of servicing the gas and electrical components is though the
fireplace. This procedure requires removing the glass panel(s) and interior design media, and lifting the grill, burner, and bottom
pressure release valve.This will increase service time and difficulty.An access panel is always preferred. Fireplace dealers/installers
are advised to consult with their clients regarding the advantages and disadvantages of each service option.
RECEIVED
09/p1e/8 of 8022
ag
ASPEN
BUILDING DEPARTMENT