HomeMy WebLinkAboutFile Documents.1440 Crystal Lake Rd.0102-2022-BRES (10) R Li 0 Installation and Operation Manual Built-In Models I I I I I I I Manufacturer Update Serial Number 21818 and Forward AWARNING: FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage • DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas: —DO NOT try to light any appliance. I I I I —DO NOT touch any electrical switch. DO NOT use any phone in your building. —Leave the building immediately. . _- = — Immediately call your gas supplier from 1 �/ 1 a neighbor's phone. Follow the gas . 1 /// // / supplier's instructions. / — If you cannot reach your gas supplier, �o call the fire department. • Installation and service must be performed WI by a qualified installer, service agency, or the gas supplier. Built-In Models: ' DANGER Front Facing • Corner (RS/LS) HOT GLASS WILL CAUSE BURNS. Tunnel DO NOT TOUCH GLASS Three Side UNTIL COOLED NEVER ALLOW CHILDREN Space Creator TO TOUCH GLASS. Curve A barrier designed to reduce the risk of burns from the hot viewing glass is Island provided with this appliance and must be installed for the protection of children and other at-risk individuals DESIGN A o �S FRr If CEIVED 09/01/2022 Ortal Installation Manual: Built-In Models(V3.7) ASPEN BUILDING DEPARTMENT General Safety Information and Warnings 0 IMPORTANT NOTE: LOCAL CODE Local codes and regulations that are more stringent than the requirements in this manual take precedence over Ortal requirements. L WARNING: HANDLING SPACE CREATOR FIREPLACES The Space Creator fireplace must be handled with care due to its special and sensitive shape.Do not remove the securing brackets before installation. After removing the securing brackets,the appliance must be treated with care to maintain its leveled shape.Do not shake,throw,stand,or put weight on it. ©WARNING: REVIEW ALL WARNINGS Be sure to review all safety warnings and installation guidelines contained in this manual.Consider installation location,vent configuration,clearances, structural requirements, framing and finish materials, and local codes. ALL warnings and instructions apply to all products manufactured and distributed by Ortal. ©WARNING: DO NOT OPERATE FIREPLACE IF: The glass is NOT properly secured in place;Connection points are not sealed(for fireplaces with glass-to-glass connections); Glass is cracked;You smell gas;Any part of the fireplace has been under water;You have any doubt about safe operation of the fireplace;Or if any part has been under water,do not use the fireplace.Immediately call a qualified,professional service technician to inspect the fireplace and to replace Aan parts of the control system and any gas controls which have been under water. WARNING: ELECTRICAL GROUNDING All electrical connections must be properly installed, insulated, and secured to avoid potential ELECTRICAL SHOCK and FIRE HAZARD and malfunction of the system.Consult local building code requirements.In the absence of local codes,refer to the National Electric Code,ANSI/NFPA 70,or the Canadian Electric Code,CSA C22.1. ©WARNING: MATERIAL USAGE All materials and objects used to carry out the installation must be certified/approved or specified by Ortal and are suitable for use.Do NOT install the system with different materials or objects than those approved for installation by Ortal. ©WARNING: INSTALLATION AND SERVICE Installation and repairs on the fireplace and vent system must be done by an authorized Ortal qualified installer service agency or gas supplier. If these components are not installed by an authorized Ortal dealer/installer,the warranty of all components will be void and Ortal will not be responsible for any damage caused by improper installation.The fireplace should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting,bedding material,etc. Control compartments,burners and circulating air passageways of the fireplace must be kept clean.Any alteration to the product can cause soot or carbon to form and may result in damage.This damage and any other damage that results from not following the instructions outlined in this manual is not the responsibility of Ortal. ©WARNING: HEAT BARRIER A barrier designed to reduce the risk of burns from hot viewing glass is provided with this fireplace and shall be installed.The fireplace MUST not be used without the heat barrier in place.If the barrier becomes damaged,the barrier shall be replaced with the manufacturer's barrier for this fireplace. Any safety screen,guard,or barrier removed for servicing the fireplace must be replaced before operating. WARNING: FIREPLACE TEMPERATURE Due to hot temperatures,the fireplace should be located out of traffic and away from furniture and draperies. Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition.Clothing or other flammable material should not be placed on or near the fireplace.Young children should be carefully supervised when they are in the same room as the fireplace.Toddlers,young children,and others may be susceptible to accidental contact burns.A physical barrier is recommended if there are at-risk individuals in the house.To restrict access to a fireplace or stove,install an adjustable safety gate to keep toddlers,young children, and other at-risk individuals out of the room and away from hot surfaces. ©WARNING: GLASS HANDLING Only an Ortal certified installer is authorized to remove the glass using an 8-inch glass-handling suction cup. WARNING: INSTALLATION AND OPERATION The fireplace and accompanying components must be installed as an OEM installation in manufactured homes (USA only) or an aftermarket permanently located,or a mobile home,where not prohibited by local codes.The fireplace must be installed in accordance with the Manufacturer's instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States, or the Standard for Installation in Mobile Homes,CAN/CSA Z240 MH Series,in Canada.Exceeding the restrictions imposed in these instructions may result in a fire or explosion,causing property damage,personal injury,or loss of life.Ortal will not be responsible for any damage caused by improper installation.Do not store or use gasoline or other flammable vapors and liquids near this fireplace. 0 WARNING: GAS FIREPLACE This fireplace is for use only with the type of gas indicated on the rating plate.These fireplaces are not convertible for use with other gases unless a certified kit is used, and the conversion is performed by an authorized and qualified technician. Applicable standards are Vented Gas Fireplace Heaters ANSI Z21.88/CSA 2.33a and Gas-fired Fireplaces for Use at High Altitudes CAN/CGA 2.17-M91 ©WARNING: CALIFORNIA PROP 65 These products and the fuels used to operate these products(liquid propane or natural gas), and the products of combustible of such fuels, can expose you to chemicals including benzene,carbon monoxide,and ceramic fibers,which are known to the state of California to cause cancer and/or reproductive harm.For more information,visit www.p65warnings.ca.gov. RECEIVED 09/01/2022 2 ASPEN BUILDING DEPARTMENT Table of Contents "—>" Denotes new or changed information from most recent version manual. General 2 Safety Information and Warnings 2 Product Information 4 Certification 4 - Models 5 Rating Label 6 Installation 7 Prior to Installation 7 Locate the Fireplace 7 Fireplace Installation 7 First Trip to Site: Planning 7 Second Trip to Site: Installation 7 Third Trip to Site:Startup 8 Post-Installation 9 Initial Burning Period 9 Final Inspection Procedure 9 Final Checks and User Instruction 9 Building Around the Fireplace 10 Building Checklist 10 Framing 11 -* Framing Detail 11 -+ Framing Dimensions 12 5/8"Type X Drywall Requirements 17 Chase Floor/Platform 17 Hearth Extension 17 General Clearances 18 -* Heat Release 23 Air Intake 25 Mounting a TV/Artwork 27 Access Panel 29 Chase Area Minimum 29 Recessed Partial Ledge 30 Structural Weight Support 31 Step-by-Step Chase Construction 32 Finishing 33 Flush Installation 33 Recessed Installation 34 Venting 35 General Vent Requirements 35 Vent Configurations 36 Vent Restrictors 39 Restrictor Sizing Guidelines 39 Vent Clearances 42 Termination 43 Horizontal Termination Clearance Diagram 43 Vertical Termination Clearance Diagram 45 Chimney Shroud 46 Vent Installation 46 Vent Maintenance 47 Co-Axial to Co-Linear Conversion 47 Vent Configuration 48 Gas 49 Gas Pressures 49 High Altitude Requirements 49 Routing the Gas Line RE� "IED Gas Conversion 5, !1 s Gas and Electrical Components 0 9/O 1/2 O 2 2 3 ASPEN BUILDING DEPARTMENT Electrical 53 Electrical Requirements 53 Power Outage 53 Pairing the Remote and Receiver 53 Wiring Diagrams 54 Home Automation Wiring Diagram 58 Interior Design Media 58 Media Placement Guidelines 59 Glass Media Placement 59 Stone Media Placement 59 Log Media Placement 60 Operation 61 10-Button Remote Control Handset 61 Operating Instructions 61 Puck Handset 62 Operating Instructions 63 Wall Switch 64 Operating Instructions 64 MyFire App 65 Operating Instructions 65 MyFire Wi-Fi Box 65 Fireplace Maintenance 66 General Maintenance 66 Product Information Certification Built-In Model fireplaces have been tested and approved by CSA Group for safety and efficiency for use with Natural Gas(NG)and Propane (LP) only, and NOT for use with solid fuels. CSA Group is approved by the American National Standards Institute (ANSI)as an Accredited Standards Developer. Certification Standard: of°` ANSI Z21.88/CSA 2.33—2019:Vented Gas Fireplace Heaters rtt ANSI Z21.50/CSA 2.22—2019: Decorative Vented Gas Fireplaces c us Products: CLASS 2901 84: DOMESTIC HEATERS(GAS)Vented Fireplace: Certified to US Standard CLASS 2901 04: DOMESTIC HEATERS(GAS)Vented Fireplace The fireplaces are permitted for indoor use only. "Indoor" is defined as a conditioned space. The fireplaces are not approved for outdoor or partial outdoor installation. Exception: Tunnel models with the Ortal "Indoor-Outdoor Kit" are approved for partial (indoor-outdoor) outdoor installation. The fireplaces must be installed while maintaining required clearances. Installation is recommended in living spaces such as bedrooms, living rooms, great rooms, etc. The fireplaces are not approved for closet installation. The fireplace must be installed according to Ortal requirements in addition to any local codes that may apply, such as USA:ANSI Z223.1/NFPA 54, Canada: CSA B149. IMPORTANT—PLEASE READ: • It is the responsibility of the fireplace dealer and installer to ensure that this fireplace is installed and framed in compliance with these instructions and all applicable codes. • Before starting,take careful note of ALL the WARNINGS in this manual. • Consult the authority having jurisdiction to determine the need for a permit prior to starting the installation. Patent Pending for screen barrier glass bracket:USSN 60/040,074 RECEIVED 09/01/2022 4 ASPEN BUILDING DEPARTMENT - Models This manual provides instructions for the following models. Please refer to the Ortal website for Product Dimensions. Series Models Burner Certification Available Direct Venting Standard Gas Types Standard: Type: Passive Vent US:ANSI Z21.88-2019 Natural Gas Vent Size:4"x6"co-axial 40 40H70 F/RS/LS/TS/TN 30 Single Canada: CSA 2.33-2019 or Propane Optional: Type: Power Vent Vent Size:3"x5"co-axial Standard: Type: Passive Vent 60x80 F/TN Vent Size:4"x6"co-axial Island 70 Optional: 60 Natural Gas 75 F/RS/LS/TS/TN US:ANSI Z21.88-2019 Type: Power Vent 70 Space Creator 75 45 Single Canada: CSA 2.33-2019 or Vent Size:3"x5"co-axial 75 75x65 F/TN Propane (does not apply to Island) -*31H (aka 75x65H)F/TN Optional: Island 70 only Type: Enervex Power Vent Vent Size:4"x6"co-axial Standard: Stand Alone 75x65 Curve Type: Passive Vent (aka Curve 270) U US:ANSI Z21.88-2019 Natural Gas Vent Size:5"x8"co-axial Curve Stand Alone 75x65 Curve TN 45 Double Canada:CSA 2.33-2019 or (aka Curve 360) Propane Optional: Type: Enervex Power Vent Vent Size:5"x8"co-axial Standard: Type: Passive Vent Vent Size: 5"x8"co-axial 110 F/RS/LS/TS/TN 110H F/RS/LS/TS/TN Optional: 110 Natural Gas 120 Space Creator 120 100 Single US:ANSI Z21.88-2019 or Type: Power Vent 130 130 F/RS/LS/TS/TN Canada: CSA 2.33-2019 Pro pane Vent Size:3"x5"co-axial 130H F/RS/LS/TS/TN p (does not apply to Island) Island 130 Optional: Island 130 only Type: Enervex Power Vent Vent Size:5"x8"co-axial Standard: 150 F/RS/LS/TS/TN Type: Passive Vent 150H F/RS/LS/TS/TN Natural Gas Vent Size:5"x8"co axial 150 Space Creator 150 135 Single US:ANSI Z21.88 2019 or 170 170 F/RS/LS/TS/TN Canada:CSA 2.33-2019 Propane Optional: 170H F/RS/LS/TS/TN Type: Power Vent Vent Size:3"x5"co-axial Standard: 200 F/RS/LS/TS/TN Natural Gas Type: Passive Vent 200 200H F/RS/LS/TS/TN 160 Sin le US:ANSI Z21.88-2019 or Vent Size: 5"x8"co-axial Space Creator 200 g Canada: CSA 2.33-2019 Propane Optional: Type: Power Vent Vent Size:3"x5"co-axial Standard: Type: Passive Vent 250 F/RS/LS/TS/TN US:ANSI Z21.88-2019 Natural Gas Vent Size:5"x8"co-axial 250 250H F/RS/LS/TS/TN 180 Single Canada:CSA 2.33-2019 or Propane Optional: Type: Power Vent Vent Size:3"x5"co-axial NOTE:Venting is not supplied by Ortal with the fireplace.The fireplace is certified to be used with,and can be obtained from,the vent manufacturers outlined in"General Venting Requirements"section. RECEIVED 09/01/2022 5 ASPEN BUILDING DEPARTMENT Rating Label The following figure shows a sample certification label for various product series. The fireplace rating label is found on a separate metal plate that is included with the fireplace. DEALERS/INSTALLERS: You MUST leave the fireplace's rating label with the fireplace in an area easily accessible by the owner (typically near the access panel, if available).You must instruct the owner before handing over the fireplace where this label can be found. OWNERS: Make sure the installer leaves your fireplace's rating label in an area that is easily accessible for you.This information is required for servicing and receiving replacement parts. RT,L,L® cusOr 0 �m Manufacturer/Fabri can t Oriel Ltd. For use only with vent,glass and interior design media certified 14 Haharash St.Hod Hasharon,4524087 and approved for use with the appliance. Not for use with solid Israel fuel.For use with barriers certified for this appliance only. Tel:011-972-9-7402828 Fax:011-972-9-7402687 Utilisez uniquement avec des conduits,des panneaux vitres et des accessoires decoratifs interieurs homologues et approuves ❑ ORTAL pour une utilization avec cet appareil.Pas pour l'usage avec le combustible solide.Pour une utilisation avec des barrieres ❑ LYRIC certifiees pour cet appareil uniquement. Serial No.: Approved By: CSA No.:2358468 Homologue Par: Tested to: CSA/ANSI Z21.88-2016•CSA 2.33-2016 for Vented Gas Fireplace Heater Examine a: CSA/ANSI Z21.88-2016•CSA 2.33-2016 pour Poeles-foyers ventiles Altitude rating: 0-2000 ft./0-610 m. Electrical Rating: 110 volt/60 Hz/less than 5A Estimation d'altitude: Estimation Electrique: Model Series!Modele Series:110-130 With 100 Burner ❑ Clear 110/RS/LS/TS/Tunnel 0 Clear 130/RS/LS/TS/Tunnel 0 Clear-110 Base ❑ Clear 110H RS/LS/TS/Tunnel 0 Clear 130H RS/LS/TS/Tunnel ❑ Clear-110TS Base ❑ Clear 110HH RS/LS/TS/Tunnel 0 Clear 130HH RS/LS/TS/Tunnel 0 Island 130 ❑ Stand Alone 110/TS 0 Space Creator 120/Mini/Midi 0 Space Creator 120H Fuel Type/Type de combustible: ❑ NG/GN 0 PROPANE Single Orifice Double Orifice Single Orifice Double Orifice Max Input/Debit max.(BTU/HR): 37,167 42,185 35,316 42,185 Min Input/Debit min.(BTU/HR): 22,798 28,878 25,113 28,878 Orifice Size!Taille de('orifice: 1200 650F+650R 380 180R+180F Gas Inlet Pressure(W.C.)inches: 7.0 7.0 11.0 7.0 Pression d'enlree de gaz(CE)pouces: - Gas manifold Pressure(W.C.)inches: 5.6 5.0 10.0 5.0 Pression d'alimentation(CE)pouces: Clearances to Combustibles: Sides: Back: In front of Glass Espacement par rapport aux materiaux inflammables: Cotes: 2" Arriere: 2" Devant le panneau vitre: 40" Also adhere to clearance diagrams and instructions included in the ORTAL manual. Adherer regalement aux schemes d'espacement et des instructions figurant dans le manuel ORTAL. SKU:M209-B100DS Sample Rating Label RECEIVED 09/01/2022 6 ASPEN BUILDING DEPARTMENT Installation Prior to Installation Locate the Fireplace Keep the following factors in mind when selecting a location for the fireplace: • Fireplace clearance requirements(review"General Clearances"sections starting on page 18). • Heat release and air intake requirements(review"Heat Release"section on page 23 and"Air Intake"section on page 25). • Adequate space for servicing. • Access panel recommendations(review"Access Panel"section on page 29). • Minimum vertical vent rise,allowed horizontal lengths, and elbow usage(review"Venting"section starting on page 35). • Framing and finishing requirements(review"Framing"starting on page 11 and"Finishing"section starting on page 33). • Front wall installation and finishes to be completed after fireplace and vent installation(review"Step-By-Step Chase Construction"section). • Floor or Platform requirements(review"Chase Floor/Platform"section on page 17). Fireplace Installation Use the following guidelines to ensure a smooth installation. The installation sequence is divided into three phases: Planning, Installation,and Startup. First Trip to Site: Planning Consult with the contractor and go over all requirements: • Chase framing requirements. • 5/8"Type X Drywall(or equivalent)requirements. • Heat release requirements. • Air Intake requirements(if applicable). • Access panel size and location. • Gas and electric specs and location. • Vent configuration. • Finishing details. NOTE: Provide the contractor with a printed copy of the"Building Checklist"and review requirements with them. Second Trip to Site: Installation • Confirm the following items are properly located and built to specification: • Framing(with 5/8°"Type X Drywall) • Platform • Gas and electric • Access panel (if applicable) • Heat release • Air intake(if applicable) • Clear a path free of any possible obstruction to carry in the fireplace. • Uncrate the fireplace and set in place. • Secure the fireplace by attaching the seismic brackets to the framing.See"Securing the Fireplace"section on the next page. • Remove plastic sleeve covering pilot tube and electrical wires. • Remove all zip ties. • Optional: Remove gas and electrical components from metal shipping plate if desired. • Move the components to the access panel location. Be mindful of the routing for future service needs. • Verify the light grounding cable is connected to the firebox. • Install the vent components. See"Vent Installation"section on the next page. • Review the front wall requirements(see"Step-By-Step Chase Construction"section on page 32)and finishing details with the contractor. • Protect the fireplace and components from damage. WARNING: HANDLING SPACE CREATOR FIREPLACES The Space Creator fireplace must be handled with care due to its special and sensitive shape. Do not remove the securing brackets before installation.After removing the securing brackets, the appliance must be treated with care to maintain its leveled shape. Do not shake,throw, stand, or put weight on it. WARNING: LIP INSTALLATION IN H FIREPLACES To ensure the glass is removable after installation, Magnetic Screw(Part#M03)under the fireplace lip must be secured tightly to the firebox and screwed in as far as possible prior to installation of framing and finish material. If the magnet is not completely screwed down into the firebox,the lip will sit ajar to the firebox, preventing glass removal. RECEIVED 09/01/2022 7 ASPEN BUILDING DEPARTMENT Securing the Fireplace During shipping, two L-shaped seismic brackets are attached from the fireplace to the crating for stabilization. These brackets must be re-used during installation to secure the fireplace to the back(or side)framing. It is crucial to the finishing that the fireplace /°/ is stable, level, and plumb. For added stability (though not required), re-use the leg shipping brackets to secure the legs of the fireplace to floor/platform. Vent Installation Venting must be installed according to the requirements detailed in the"Venting"section •• - of this manual in conjunction with the vent system manufacturer's installation m ' ' instructions. Venting must be supported by the structural surrounding and not by the • • fireplace. Each offset (elbow) must be strapped to reduce movement or possible ' • • disconnection. • ' The first section of venting must be secured to the fireplace starter collar with a minimum of 3 sheet metal screws no longer than'A". DO NOT use silicone to seal the sections. If sealing is required by the vent manufacturer or local code, use Mil-Pac sealant. .////// Seismic Bracket Third Trip to Site: Startup • Perform a visual inspection to confirm that all work was completed correctly and per specification. • Confirm that gas and electric are properly connected and live and operating the specs specified within this manual. • Remove the safety barrier and glass and clean the inside of the fireplace. • Install the Interior Design Media (if desired)on the burner as specified in "Interior Design Media" section starting on page 58. • Confirm the fireplace is operating properly. • Check remote-control setup. • Remove protective layer from glass. • Clean glass. • Reinstall the glass and safety barrier. • Review operation of the fireplace and remote control with the owner. • Set up return visit to clean glass after the Initial Burning Period(see"Post-Installation"section on the next page). Working with Glass Panels Inner glass panel is 5mm ceramic glass. For fireplaces with a double glass heat barrier,exterior glass panel is 3/16"tempered glass. Silicone comes pre-applied to any glass-to-glass connections (multi-sided models), on both sides of the glass. Keep the following guidelines in mind when handling silicone and glass panels: The purpose of the silicone is to create a gasket, not to"glue"the glass panels together.When placing glass panels, ensure that the glass is fully in place and that the silicone is filling the space between the glass panels. Place the front(or center)panel in place first and then slide the side panel into place so that the silicone edge touches the glass edge. • Re-apply silicone only if the original silicone is damaged Side Glass (Rutland 500°Clear Silicone is recommended). • If new silicone is applied,cure time is 24 hours before operation of the fireplace. • Do not use silicone to seal the glass after it is in place. _ • Always use appropriate materials and cleaning agents MIMES to clean glass.Ammonia free glass cleaners and/or -- • ceramic glass cleaners are recommended. NFront Glass Silicone is applied where glass panels meet, to close any 1E::®!■e distance between. Side Glass / Glass Seal Assembly Diagram RECEIVED 09/01/2022 8 ASPEN BUILDING DEPARTMENT Post-Installation Complete the following post-installation steps upon 4th trip to site. Initial Burning Period There is a 12-hour minimum burning period following installation of the fireplace.This 12-hour period must include a minimum of 4 consecutive hours of continuous burning. During this time,the owner or installer may notice: • The glass developing a white or"cloudy"residue. • An unusual smell Both the residue and the smell are due to the paint on the fireplace metal heating and "burning off'.This is normal. The cloudiness and odor will disappear after the 12-hour period elapses and the installer returns to service the fireplace and complete startup. Final Inspection Procedure When the 12-hour burning period is complete,the installer must return and perform the final inspection,which includes: • Cleaning the glass with a ceramic glass cleaner(otherwise the white residue will remain) • Checking the interior media setup • Checking for gas leaks • Adjusting the restrictor(if necessary) • Performing an overall check to make sure that all systems and components is working properly. When these activities are complete, initial startup is concluded and the fireplace may be operated by the owner. Final Checks and User Instruction Before releasing the fireplace to the customer for use without installer supervision, the installer must ensure that the fireplace is burning correctly. In addition,the installer must review and explain the following to the owner: • Safety warnings • Fireplace operation • Warranty requirements • Maintenance requirements • Glass and firebox components are hot during and after operation. • If any questions or concerns arise,owner must contact the local Ortal dealer/installer for support. RECEIVED 09/01/2022 9 ASPEN BUILDING DEPARTMENT Building Around the Fireplace Building Checklist The following building checklist is a quick reference for a typical Ortal Built-In Series fireplace installation. This list is not exhaustive and does not supplement thorough review of the installation manual. O Fireplace Location: Ensure the location allows for min. 36" clearance from viewing area to combustibles and 12" to non-combustibles. Make sure a clear path is established to allow the fireplace to be safely transported to installation location. O Venting: Confirm vent size (either 4"x6" or 5"x8" for natural vent and 3"x5" for power vent), vent clearance (1" on sides and bottom, 3" on top), vent configuration, and termination location. O Height from Floor: Fireplace leg height is 9 13/16" (to bottom viewing area). Legs cannot be removed/altered. If desired viewing area location on the wall is higher than 9 13/16', a platform can be built for the fireplace to stand on. O Chase Floor/Platform: Fireplace can stand on the chase floor or a platform. Floor or platform must be able to bear the weight of the fireplace. It can be constructed out of wood, concrete, metal, or any other solid materials (not required to be non-combustible). O Chase Construction: No materials can be attached directly to the fireplace (exception: 5/8" Type X Drywall). The area of the chase interior must meet minimum chase area requirements (depending on the model). All chases require a heat release, and double glass fireplaces require and air intake (details below). O Framing: Adhere to minimum framing dimensions (or greater). Keep min. 2" clearance from back and sides (as applicable by model) of fireplace to any material. The first 18" above the top of the fireplace viewing area must always be non-combustible framing. Maintain min. 1/4" clearance from front face of fireplace and front metal off-set to the framing. Maintain min. 4" space between air vents at top of fireplace to any material. For recessed fireplaces, do not exceed 12" max. front overhang depth limit. Side overhang depth is unlimited. No material is permitted to extend past the metal lip surrounding the fireplace viewing area to allow for glass removal. O 5/8" Type X Drywall Requirements: One layer of 5/8" Type X Drywall (or equivalent) must be installed on the exterior of the chase framing. O TV/Artwork: TV/Art must be min. 12" above top of fireplace viewing area. O Gas Supply Line and Power Location: Locate gas line with manual shut off according to local code. Power provided by single gang 120V outlet in same area as gas line. O Access Panel: Access panel highly recommended to access gas and electrical components for servicing. Depending on the model, access panel can be placed at side or back of the fireplace within 3' of the pilot. Access panel or some other form of clear access to the chase is required for power- vented fireplaces. Size recommendation: as large as possible depending on application. Min. recommended size 10"x10". O Heat Release: Crucial for Cool Wall Technology. Must start within 6" (max.) from the chase's ceiling. Heat release must meet minimum size (depending on the model) of net free air space. Height of the heat release must not exceed 1/3 of the width. O Air Intake: Only required for double glass heat barrier. Must be located at or below level of double glass fans. Air intake must meet minimum size (depending on the model) of net free air space. O Finishing: For finishes flush to the fireplace, no clearances are required. For finishes where the fireplace is recessed to the finish, maintain 1/8" from the finish to the front face of the fireplace. RECEIVED 09/01/2022 10 ASPEN BUILDING DEPARTMENT Framing Fireplace chase may be framed with either combustible (typically wood studs) or non-combustible framing (typically metal studs). Any framing within 18 inches from the top of the fireplace glass(viewing area)must be non-combustible.This does not apply to the framing to the back or side(s)of the fireplace;these may be combustible. The fireplace is non-load bearing.The framing of the fireplace chase must be designed to carry the entire weight of the wall and finish material.Surrounding material must not transfer weight to the fireplace(exception:5/8"Type X drywall or equivalent),or be connected in any way to the fireplace. No material is permitted to extend past the metal lip surrounding the fireplace viewing area.This area must be unobstructed to allow the heat barrier and inside glass panel to be removable. - Framing Detail The detail below shows general framing requirements for a fireplace built flush to the finish wall. It is not to drawn to scale and is intended for illustrative purposes only. For a complete list of clearance requirements, please see"General Clearances"on page 18. Dimension labels below correspond with the diagrams in the"Framing Dimensions"section starting on the next page. Dimension A: Rough Combustible Framing Opening Height Dimension B: Rough Framing Opening Width Dimension C: Framing Depth Dimension D: Firestop Opening Dimension E: Non-combustible Framing Zone(applicable only when also framing with combustible framing) Dimension D ,1 r 11 ` 1 I hot air lbw/ \ Heat Release Heat Release_ -5/8"Type Drywall 5/8"Type Drywall (required on exterior side C (required on exterior of framing only) side of framing only) Combustible Framing _,; — W Non-Combustibleif1IIpI 1"min _ p Framing ( / clearance to pipe I I4"clearance xi Sim 17 %� Top Drywall Lip,' 2"min 2"min clearance This stud must have a vertical orientation to allow, �� to sides of fireplace for airflow above the fireplace. airflow path q Q -- for screen c m / ` c B f ar ( I 2"min Side Drywall ---Side Drywall Lip o c I f % clearance"•hind Lip e /r fireplace 1 -� Bottom Drywall Lip •70% ik �', Combustible Framing n . r II airflow path for 1 r —— double glass — I_ Dimension B 1�———— Movable Gas/ Electrical Components' Elevation View Air Intake Section View (required for double glass only) C.) "The gas/electrical components can be moved up to 36" Non-Combustible Framing I c from the center of the fireplace to desired access panel 'Eg location. Combustible Framing nl 111114- 11 I N c tb rr'" -'r• ,r E ■ Clearance area.No O No weight can be transferred to building material permitted. 2_min I I 2"min the fireplace.ALL FRAMING MUST BE SELF-SUPPORTED. Top View NOTE: Fireplace model used in framing detail below is a 31H Front.All information shown in this detail applies to all fireplaces mentioned in this manual. IMPORTANT: To ensure the glass is removable after installation, Magnetic Screw (Part#M03) under the fireplace lip i must be secured tightly to the firebox and screwed in as far as possible prior to installation of framing and finish material. If the magnet is not completely screwed down into the firebox,the lip will sit ajar to the firebox, preventing glass�e,�yyngval // i/2 022 11 ASPEN BUILDING DEPARTMENT -� Framing Dimensions The following diagrams are for illustrative purposes only.There are multiple approved installation scenarios.A flush application is not the only permitted application.The fireplace may be recessed into the wall. Refer to diagrams and values below and in the following pages for details. Space Creator Series Framing Combustible Framing mon'CombusUb|vFmming Frarring gg ^ E nq | | ^ MEMO� | RM111"It . � &mwaam|mG-M4|mTA|m/umFLOxxCLsAm4mCs: Fireboofrountbopventmusthmvaminimum4" ofcleoronoebo any material achieve ouff|o|emt airflow (sea nn. 21). Failure to do so could result in improper fireplace operation, property damage,o,physical injury. Review"General Clearances"section (p9. 1u)prior tn framing to ensure all clearances are followed. Muuo| Framing Dimension Dimension Dimension Dimension Dimension Combustible 44,8' � 13'/v'' GC75 379o^ 193�^ ' Non-Combustible 307/81, N/A Combustible 44,6^ 12r6^ GC12O 50�� 1o�� R*�r0n�po Non-Combustible 31 " ^ manufacturer's N/4 Combustible 441/2" fimstoP 127/8" GC 150 Non-Combustible 31 56. 08s6^ 1898^ dimensions N/A GC2OO Combustible 4416^ 08�� 19�� 12r6^ Non-Combustible 31 � N/A RECEIVED 09/0I/2022 12 ASPEN BUILDING DEPARTMENT Front Facing Series Framing Combustible Framing Non-Combustible Framing Nil Ili 11111 s \el I Camb�s5ble \ 3s\�� �� /II 11 pmI NarCanbustlbk m..c e4 Fnirt \�0 @� �\ Freming \ Ii'N • \�\ M� :♦ SIB'Tyre X i\\, 3�\ ��� 3;�ii ��°x0 \ .,� 5/r TypeX s� sjIi$ji, r\r \ ��a ��3@g°x, l icefl j � aa� @�aa \°°` A ,,§0 N1 I illtiii t-� ;. t, g I ‘,&\ . i a>vmrab� . C i►� &WARNING—MAINTAIN AIR FLOW CLEARANCE: Firebox front top vent must have minimum 4" of clearance to any material achieve sufficient airflow(see pg. 21). Failure to do so could result in improper fireplace operation, property damage, or physical injury. Review"General Clearances"section(pg. 18)prior to framing to ensure all clearances are followed. Model Framing Dimension A Dimension B Dimension C Dimension D Dimension E 40H70 F Combustible 55 3/8" 24 5/8" 18" 14 1/4" Non-Combustible 41 1/4" N/A 75 F Combustible 45 1/8" 37 3/4" 177/8° 15 3/s" Non-Combustible 29 7/8" N/A 75x65 F Combustible 53 3/8" 38 /s" 18" 15 1/8" Non-Combustible 38 3/8" N/A —> 31H F Combustible 92 5/16" 38 13/16" 19 5/8° 13 3/4" (aka 75x65H F) Non-Combustible 78 7/8" N/A 60x80 F Combustible 57" 29 3/8" 18" 14 5/8" Non-Combustible 42 3/8" N/A 110 F Combustible 41 5/8" 51 '/a" 18" 14 1/8" Non-Combustible 27 1/2" N/A 110H F Combustible 49 1/2" 51 '/s" 18" 14 1/8" Non-Combustible 35 3/8" N/A 130 F Combustible 41 5/8" 58 5/8" 18" 14 1/8" Non-Combustible 27 1I2" Refer to pipe N/A Combustible 49 1/2" manufacturer's 14 1/8" 130H F Non-Combustible 35 3/8" 58 5/a 18" firestop N/A Combustible 415/8" dimensions 14 1/8" 150 F Non-Combustible 27 1/2" 68'/2 18" N/A 150H F Combustible 49 1/2" 681/2" 18" 14 1/8" Non-Combustible 35 3/8" _ N/A 170 F Combustible 41 5/8" 76 3/8" 18" 14 1/8" Non-Combustible 27 1/2" N/A 170H F Combustible 49 1/2" 76 3/8" 18" 14 1/8" Non-Combustible 35 3/8" N/A 200 F Combustible 41 5/8" 85 3/4" 18" 14 1/8" Non-Combustible 27 1/2" N/A Combustible 49 1/2" 85 3/a" 18 /s° 14 1/8" 200H F Non-Combustible 35 3/8" _ N/A Combustible 43 5/8" 14 104 3/a" 18"250 F Non-Combustible 29 1/2" N/A 250H F Combustible 49 1/2" 104 3/8" 18" 14 1/8" Non-Combustible 35 3/8" N/A 09/01/2022 13 ASPEN BUILDING DEPARTMENT Corner(RS/LS)Series Framing Combustible Framing Non-Combustible Framing ''47�Il� IL/� �II I �II►rji� i �% �1iI �'// , oil , I V. 11., Combustible ,\\ \ � I\. \ \�' Combustible \.\\� \II III I II' Framing Non-Combustible t\ .`k.\, ,\\\ i* k\!!1! OiIP':ç 518"TyPeX —.,\ \'\\ \.\ j\$: \ \ \. \:a A :,� �,p\.,�,`;\,\\\�\;`�\ \�.\`, \ \\ ie\ \ \`0 E j \\\\� uhIh]1iijI \\\�\\\\� 4.o'\,......,\5;.....\��` \ �\� \ \ \ \\ \ _ \\\\\ \\\\\ 11111111 \\\\\\\\\\\\\\\\\\�\\\\\ \\\\ �I \\\\\ I \\\\\\'.•`o \\ -L '„a\\\ \ \ II' Non-Combustible \i�,�\\.\\Framing vvvvyA\v B B C C &WARNING-MAINTAIN AIR FLOW CLEARANCE: Firebox front top vent must have minimum 4" of clearance to any material achieve sufficient airflow. Failure to do so could result in improper fireplace operation, property damage,or physical injury.See page 21 for details. Review"General Clearances"section prior to framing to ensure all clearances are followed.See page 18 for details. Model Framing Dimension A Dimension B Dimension C Dimension D Dimension E Combustible 55 3/8" 14 1/8" 40H70 RS/LS 24 1/4" 18 3/8" Non-Combustible 413/8" N/A Combustible 46 3/4" 13 1/4" 75 RS/LS 35 1/a" 20 1/8" Non-Combustible 331/2" N/A Combustible 43 5/8" 12 1/2" 110 RS/LS 50 3/4" 20 5/8" Non-Combustible 311/8" _ N/A 110H RS/LS Combustible 49 1/2" 51" 22 /a" 12 5/8 Non-Combustible 36 7/8" N/A Combustible 43 5/8" 12 1/2" 130 RS/LS 57 3/8" 20 5/8" — Non-Combustible 311/8" N/A Combustible 49 1/2" 12 5/8" 130H RS/LS 57 5/8" 22 1/4" Non-Combustible 36 7/8" N/A Combustible 43 5/8" 121/z Refer topipe 150 RS/LS 67 1/4" 20 5/8" Non-Combustible 31 1/8" manufacturer's N/A Combustible 49 1/2" firestop 12 5/8" 150H RS/LS 67 1/2" 22 1/4" dimensions Non-Combustible 36 7/8" N/A 170 RS/LS Combustible 43 5/8" 75 1/8" 20 5/8" 12 1/2" Non-Combustible 31 1/8" N/A Combustible 49 1/2" 12 5/s" 170H RS/LS 75 3/8" 22 1/4" Non-Combustible 36 7/8" N/A Combustible 43 5/8" 12 1/2" 200 RS/LS 84 5/s" 20 5/s" Non-Combustible 31 1/8" N/A Combustible 49 1/2" 12 5/8" 200H RS/LS 84 7/s" 22 1/4" Non-Combustible 36 7/8" N/A Combustible 43 5/s" 12 1/2" 250 RS/LS 104 1/4" 20 5/s" Non-Combustible 31 1/8" N/A Combustible 49 1/2" 12 5/s 250H RS/LS 104 1/2" 22 1/4" Non-Combustible 36 7/8" N/A RECEIVED 09/01/2022 14 ASPEN BUILDING DEPARTMENT —> Tunnel Series Framing Combustible Framing Non-Combustible Framing ii-: - -. „.........„.„....... Sla. 11� .� i ill1 III Combustible \ \ \\--NtA\‘' �� °Q Framing \�\a's\\s\\ IlIlUiHilir Nan ZlIxistlble ,_ Non-Combustible '.� �iQ? �!\a0 \ T .1��'as\\�k'4Li Framing ,� \.\��0�\.0\,ii ,,‘ \i ` �. \�` i\. \� YDe \\ON'\ \ �\� \\� .0 r. > °�'��.a 5/B Type x °s € ��?i ti i . _.a._Q\S. J1 ! TIk .,\ x 'Ik '� \ II x � � e 0\a ' �a B _..:-- ' te „_c�C &WARNING—MAINTAIN AIR FLOW CLEARANCE: Firebox front top vent must have minimum 4" of clearance to any material achieve sufficient airflow. Failure to do so could result in improper fireplace operation,property damage, or physical injury.See page 21 for details. Review"General Clearances"section prior to framing to ensure all clearances are followed.See page 18 for details. Model Framing Dimension A Dimension B Dimension C Dimension D Dimension E Combustible 55 3/8" 14 3/8" 40H70 TN 24 5/8" 18 7/8" Non-Combustible 41" N/A Combustible 53 3/8" 15 1/8" 75x65 TN 38 3/8" 18 7/8" Non-Combustible 38 3/8" N/A 31 H TN Combustible 92 9/16" 13 3/4" (aka 75x65H TN) Non-Combustible 74 13/15" 36 13/1s' 15 1/2" N/A Combustible 57" 14 5/a" 60x80 TN 29 3/8" 18 7/8" Non-Combustible 42 3/8" N/A Combustible 415/8" 141/8" 110 TN 51 7/8" • 19" Non-Combustible 271/2" N/A Combustible 49 1/2" 141/8" 110H TN 51 7/8" 19" Non-Combustible 35 3/8" N/A Combustible 415/8" 141/8" 130 TN 58 5/s" 19" Non-Combustible 27 1/2" N/A Combustible 49 1/2" 141/8" 130H TN Non-Combustible 35 3/8° 58 5/a 19" Refer to pipe N/A manufacturer's Combustible 415/8" firestop 141/a" 150 TN 68 1/2" 19" dimensions Non-Combustible 27 1/2" N/A Combustible 49 1/2" 141/s" 150H TN 68 1/2" 19" Non-Combustible 35 3/8" N/A Combustible 415/8" 141/8" 170 TN 76 3/8" 19" Non-Combustible 27 1/2" N/A Combustible 491/2" 141/8" 170H TN 76 3/8" 19" Non-Combustible 35 3/8" N/A Combustible 415/8" 141/8" 200 TN 85 3/4" 19" Non-Combustible 271/2" N/A Combustible 491/2" 141/a" 200H TN 85 3/4" 19" Non-Combustible 35 3/8" N/A Combustible 43 5/8" 14 250 TN 104 1/4" • 19" Non-Combustible 29 5/8" IN/A i,; , Combustible 49 1/2" 14 250H TN 104 1/4" 19" Non-Combustible 35 1/2" N/A 09/01/2022 15 ASPEN BUILDING DEPARTMENT Three Side Series Framing Combustible Framing Non-Combustible Framing iD i %I jl %jam \Nill ILIli IICombustibleIII\ � „\ \�\\��\ Flaming „ \ � �I 'II Non-Combustible \\\\�\\\ \IIIIIIII i\\\�\\\ \„Mit Framing \\ \T-- ., ,,,‘,„„„,,,,,„,, , \ �� \.\ SN3"Type X _ :\\�,�\,\ ,, ,e\\ , ,‘s \\o. .\ Ilkill*ii1101 moo �_' - Non-Cogmbustlble _ - _ t Fremin i�_--_ 1111111 B �."�=fC B ��=fC ��/ _yam/ &WARNING-MAINTAIN AIR FLOW CLEARANCE: Firebox front top vent must have minimum 4" of clearance to any material achieve sufficient airflow.Failure to do so could result in improper fireplace operation,property damage, or physical injury.See page 21 for details. Review"General Clearances"section prior to framing to ensure all clearances are followed.See page 18 for details. Model Framing Dimension A Dimension B Dimension C Dimension D Dimension E Combustible 55 3/8" 14 1/8" 40H70 TS 22 3/8" 18 1/4" Non-Combustible 413/8" N/A Combustible 46 3/4" 13 1/4" 75 TS 33 5/8" 20 1/8" Non-Combustible 331/2" N/A Combustible 43 5/8" 12 1/2" 110 TS 49 20 5/8" Non-Combustible 311/8" N/A 110H TS Combustible 49 1/2" 49 22 1/4" 12 5/8" Non-Combustible 367/8" N/A Combustible 43 5/8" 12 1/2" 130 TS 55 5/8" 20 5/8" Non-Combustible 31 1/8" N/A Combustible 49 1/2" 12 5/8" 130H TS 55 5/8" 22 1/4" Non-Combustible 367/8" N/A Combustible 43 5/8" Refer to pipe 12 /2 , a 150 TS 65 /2" 20 /8" pip Non-Combustible 31 1/8" manufacturer's N/A Combustible 49 1/2" firestop 12 5/8" 150H TS 65 1/2" 22 1/4" dimensions Non-Combustible 367/8" N/A Combustible 43 5/8" 12 1/2" 170 TS 73 3/8" 20 5/8" - Non-Combustible 311/8" N/A Combustible 49 1/2" 12 5/8" 170H TS 73 3/8" 22 1/4" Non-Combustible 367/8" N/A Combustible 43 5/8" 12 1/2" 200 TS 82 3/4" 20 5/8" Non-Combustible 311/8" N/A Combustible 49 1/2" 12 5/8" 200H TS 82 3/4" 22 1/4" Non-Combustible 367/8" N/A Combustible 43 5/8" 12 1/2" 250 TS 102 1/2" 20 5/8" — Non-Combustible 311/8" _ N/A Combustible 49 1/2" 12 5/8" 102 t/z" 22 t/a"250H TS Non-Combustible 36'/8" N/A RECEIVED 09/01/2022 16 ASPEN BUILDING DEPARTMENT 5/8" Type X Drywall Requirements Exterior side(i.e.,room-facing side)of the framing must be covered with 5/8"Type X Drywall(or equivalent).Finish material is installed on top of the drywall.This applies to combustible and non-combustible framing. Drywall is not required on the exterior portion of an insulated outside-facing wall. 5/8"Type X Drywall may rest on the metal lip surrounding the opening of the fireplace. Drywall must not be attached to the fireplace as heat transfer from attaching materials(such as screws)can cause the drywall to crack. No material is permitted to extend past the metal lip surrounding the fireplace viewing area.This area must be unobstructed to allow the heat barrier and inside glass panel to be removable. \\N\ �1111111111M 11111111 11= aIii Combustible: 'I \� a Framing 1 \ a , \ z a $ 8�,Type X � :. Drywall itl*j �1�,. �\•���� 1111�� Chase Floor/Platform The fireplace must be installed on a flat,solid,continuous surface.Surface can be wood,concrete, metal,and other typical solid floor types. Surface material is not required to be non-combustible. Fireplace leg height is 9 13/16"(measured to bottom of viewing area). Legs cannot be removed,cut, or adjusted. Raised Platform Option: To raise the fireplace higher than 9 13/16" height, build a platform for the fireplace to stand on. Platform must be stable and able to bear the full weight of the fireplace.Platform can be constructed out of wood,concrete,metal,or any other solid materials. Platform material is not required to be non-combustible. • as o rig G Ian o e9 _. �• 1 • 0 e p BE 0E O 0 fD • 0, Fireplace Leg Height NOTE:For fireplaces with the double glass heat barrier,an air intake might be necessary to incorporate into the platform depending on the design.See"Air Intake for a Platform"for details. Hearth Extension A hearth extension is not required. Any hearth extension used is for appearance only and does not have to conform to a standard hearth extension installation requirement. RECEIVED 09/01/2022 17 ASPEN BUILDING DEPARTMENT General Clearances Viewing Area Clearances The viewing area clearance zone is an area that extends perpendicular from the fireplace viewing area. The depth of the viewing area clearance zone depends on the combustibility of the material in question. Distance is measured from the fireplace heat barrier. Non-Combustible Materials Must be minimum 12 inches from fireplace viewing area. Combustible Materials Must be minimum 36 inches from fireplace viewing area. Materials(including combustible flooring and combustible finish material)are permitted below and around the viewing area clearance zone. IMPORTANT NOTE: When placing material near the glass, take care to consider fireplace serviceability. It is strongly recommended that any items/materials placed in front of the front(long)glass be movable for easy access to the fireplace during servicing. Recommendation does not apply to side(short)glass(es). Viewing Area Clearances Per Model Front cpe,o, Tunnel 0 w 4 St G <I C=) .* ' i ,,,.. 46:1, ::.:: 40%ilo. ls•to Araii# , ie.. AP. -..- .4 Corner: Left Side Corner: Ride Side '4' . 4 "I' FilkA4e _4i*1/4 ., A ''' .,„,„•,:s, popPr- Nis,01. W ' ,,i01111fr 1141% / Space Creator Three Sided 140)41,4,4, AOklil-lri-e:e , 6A1111011.11114 it ice C ► C o 0 V\\ /, mb�sGb/etb�e t .400. RECEWED 09/01/2022 18 ASPEN BUILDING DEPARTMENT Firebox Clearance Maintain a 2-inch clearance from the back and/or side of the fireplace(depending on the model)to any material. Firebox Clearance Per Model Front Tunnel = 2" min 2" min E 1 1 c ( r2" min i s L- 2 min , O CD O O i F----- ---1 i _ LLL/.- Corner: Left Side �•GG• Corner: Ride Side c c „2" min 2"min„ _� CV N I T.. 1.n.0),n,' ...• 1...• i'0°(4.9 '0°11 1 1• ra— 1 , . _4 Space Creator Three Side c_ 2" min E cV • II-E1 ..E . I°0° ��°Oal2.. Tr---- T L RECEIVED 09/01/2022 19 ASPEN BUILDING DEPARTMENT Clearance to Chase Ceiling Maintain a 12-inch clearance from the top of the fireplace viewing area to the lowest point of the ceiling or to any building materials. Keep area clear from obstruction for air circulation Heat Release must be on top or within 6" of chase ceiling. Non-combustible / framing & finish E; Nff - Y !C_ • • C r • Minimum Chase Ceiling Clearance Diagram NOTES: • A heat release is required for every installation,but it is not required to be split between the two sides of the chase as shown in the diagram above. It is shown in this diagram for illustrative purposes only.See the"Heat Release Requirements"section for details. • Clearance around the vent pipe must be maintained (1" clearance on the sides and bottom, 3" on top). See the "Vent Clearances"section for details. RECEIVED 09/01/2022 20 ASPEN BUILDING DEPARTMENT Air Flow Clearance A 4-inch clearance from the heat barrier vent openings along the top of the fireplace is required. Framing and building material is NOT permitted in this area. Doing so will block the vents and cause the entire surrounding to overheat. 11 / A Heat Barrier Vents / A . ,. , z , . 1 A I m .I I X 1 �A o e 0 r \\ ® . . / /�/ I I SIM A ,,,,% NOTE: It is acceptable if the flat stud immediately above the fireplace hangs over heat barrier vents slightly when using standard metal framing(as shown in diagram above). Framing Clearance Maintain a minimum 1/4 inches of space between the framing and the face of the fireplace. 7 A . -i, - - ice/ \ / ., / � .. g . ! I . 1 i . 1 , I . )14 „MIN ■ I 1 _ _ _ , ,1 ••• iYrY / RECEIVED 09/01/2022 21 ASPEN BUILDING DEPARTMENT Clearance to a Side Wall The fireplace viewing area is zero-clearance to a side wall.A side wall is defined as a wall that meets the viewing area at a 90°angle. 0 • (C)) O 10 O I 1111 No Max x / / I o A Alcove Side Walls(Top View) Corner Side Walls(Top View) =Building Material The temperature on the side wall can get as high as 150°F above ambient temperature. While the fireplace certification allows for this temperature variance, building and finish materials will have their own limitations. Consult the material manufacturer to ensure the material can safety withstand this temperature range. This information does not apply to a wall that is constructed in front of the viewing area. For materials that will be in front of a main or side viewing area, please refer to the"Viewing Area Clearances"section. NOTE:This section was previously titled"Clearance to an Inside Corner". Maximum Overhang Depth Overhang depth of a recessed fireplace must not exceed 12 inches. Overhang depth is measured from the edge of the fireplace lip to the out-most part of the wall (including finish material). Side overhang has no limit. Finish material on the underside of the overhang may be combustible or non-combustible. Bottom recess(or"hearth extension")has no minimum or maximum depth requirement. If bottom recess depth exceeds 12 inches, ensure the structure is capable of supporting the weight of a fireplace technician for servicing. Front(Long Side) Overhang Side (Short Side) Overhang • 12" MAX NO MAX m o Max • 1 f 1 / ax ///A RECEIVED 09/01/2022 22 ASPEN BUILDING DEPARTMENT -* Heat Release A heat release is an opening in the fireplace chase that allows the heat inside the chase to passively circulate into an interior room. This heat is generated convectively as the fireplace heats up. It is separate from exhaust heat produced at the combustion chamber of the fireplace. For safety purposes, a heat release is required to keep the wall around the fireplace cool. Heat Release Requirements • The heat release must be located at or near the top of the fireplace chase and start within 6 inches(0-6 inches max)of the chase ceiling/firestop. It can start at the chase ceiling. It can be located on the front, sides or back of the chase. It can be released into any interior space that shares a wall with the chase. • Minimum heat release size requirement depends on heat release orientation: Fireplace Horizontal Heat Release Vertical Heat Release Series 40 75* Minimum 50 sq. in. of free air space Minimum 65 sq. in.of free air space (includes 31H) _> 110-130* Minimum 120 sq. in.of free air space Minimum 156 sq. in.of free air space 150-200 Minimum 200 sq. in.of free air space Minimum 260 sq. in.of free air space 250 Minimum 250 sq. in.of free air space Minimum 325 sq. in.of free air space *Includes Built-In/Custom Curve&Island fireplaces.Heat release requirements do not apply to Curve&Island fireplaces with standard Ortal-provided hood options. • For horizontal heat releases only, the height of the heat release must not exceed 1/3 of the width. (This does not apply to vertical heat releases.) • The space the heat release vents into must have a minimum volume of 184 ft3. • The heat release can be in the form of(but not limited to)a louvered ventilation grille,gap,or reveal. • For louvered/perforated ventilation grilles, the net free air space allowed in the louvered area must be equal or greater than the minimum number of square inches required per fireplace. • The interior area of the narrowest part of the fireplace chase(in square inches)must never be less than your required heat release size(see"Chase Area Minimum"section for details). • The heat release cannot be vented outdoors or to an unconditioned space. NOTE:An angled heat release is not permitted. The following diagrams are examples of potential heat release options.These drawings serve as illustrative purposes only. Horizontal Heat Release A • 7 A • Heat Release 6"Max IAi Heat Release Imo i _ Air Flow l�.; Air Flow IIAii :W Reveal Heat Release Louvered Grille Heat Release RECEIVED 09/01/2022 23 ASPEN BUILDING DEPARTMENT Vertical Heat Release: Split Front Vertical Heat Release: Full Side The heat release is oriented vertically and split between the two sides The heat release is oriented vertically. Entire heat release of the chase. is on one side of the fireplace chase. X x-- Split Front Vertical Heat Release Full Vertical Heat Release on One Side Sprinkler Clearance to Heat Release In a situation where a sprinkler head is near the heat release, the sprinkler head must be minimum 24 inches (linear length) from any point of the heat release opening. / A Sprinkler 0 Head 24" m i n RECEIVED 09/01/2022 24 ASPEN BUILDING DEPARTMENT Air Intake When installing a fireplace with a double glass heat barrier, it is essential to maintain cool air flow between the double glass panels. For this purpose, an opening must be provided toward the bottom of the wall to allow the double glass fans to circulate room air through the glass panels and up into the chase.This opening,called an air intake, needs to be made before closing the wall surface below the fireplace.Air intake must meet the minimum size requirement. Fireplace Series Air Intake 40 130* Minimum 124 sq. in.of free air space (includes 31 H) 150-200 Minimum 200 sq. in.of free air space 250 Minimum 250 sq. in.of free air space 1 *Includes Built-In/Custom Curve&Island fireplaces.Curve&Island fireplaces with standard Ortal-provided base have an air intake already built into the base. The air intake can be in the form of a louvered/perforated ventilation grille, gap, or toe-kick(reveal). For louvered ventilation grilles, the net free air space allowed in the louvered area must be equal or greater than the minimum number of square inches required per fireplace. The entire air intake must be located at or below the level of the double glass fans.The air intake is not required to be on the front wall of the fireplace. The air intake cannot be on a wall that allows air from outside the house directly into the fireplace chase. Air must be from a conditioned space. / `KIIMMISE \ / r MGM / , �El CIC�\ r ,1 7 I km i al 1 6AT&Ti eliCt ; . . Air intake opening must / - allow for minimum Air Intake as Louvered Grille square inches of air Air Intake as Toe-kick space specified in table above. RECEIVED 09/01/2022 25 ASPEN BUILDING DEPARTMENT Air Intake for a Platform 3 3 0 0 L L a a A A 1 .a . r,11, I E • ,_ . ,_____j .. . •. .,,,,"'A'---'........"/A'S. I LEGEND :_:_:_:_:_:s: 8"Type X Drywall Combustible Framing NOTE: Please refer to the"Platform"section for details on platform construction. RECEIVED 09/01/2022 26 ASPEN BUILDING DEPARTMENT Mounting a TV/Artwork Ortal's Cool Wall Technology is a technique that reduces the convective heat from the fireplace and prevents heat buildup inside the fireplace chase, mitigating any damage that may result from the wall reaching high temperatures. Ortal's Cool Wall system enables the option of safely installing artwork, a TV, or other similar electronic components above the fireplace by reducing the wall temperature above the fireplace. Location Wall Temperature 0-6 inches above fireplace 100°F- 120°F 6-12 inches above fireplace 90°F-100°F 12 inches above fireplace 80°F-90°F Maintain the following general requirements to mount a TV or artwork above the fireplace and prevent heat damage: • Mount the TV or artwork at the minimum clearance above the top of the fireplace viewing area. Minimum clearance amount depends on flush or recessed installation.See sections below for more information. • Wires inside the chase are not permitted to cross over the fireplace.Wires must be installed against a wall. The decision to install a television above the fireplace is up to the discretion of the owner.TV and art manufacturers may specify that their product should not be installed on, near or above a heat source. Ortal will not be held liable for any adverse effects on a TV, artwork or other equipment located near the fireplace. It is the owner's responsibility to verify that their TV or artwork can withstand the wall temperatures as outlined in the above wall temperature chart. The following diagrams can be used as a guide for customers who do decide to locate their TV and artwork above their fireplace. These drawings illustrate ways of reducing the amount of heat impact to the area surrounding the fireplace. Flush Mounted TV/Artwork When the TV is mounted on a wall that is flush to the fireplace,the TV must be at least 4 inches from the top of the fireplace glass viewing area. Ensure all clearances are maintained.See diagram below for details. — ' ' ` / \ N. I I / \ / \ / ' ` \ 1 I ' I I C I N. I ' I � r \ 1 I • it r 4 m 8 :I " I 1 ` \ _ - 11 i 1-'4 NOTE:Vent clearances must be maintained. See"General Clearances"section for details. RECEIVED 09/01/2022 27 ASPEN BUILDING DEPARTMENT Recessed TV/Artwork When the TV is mounted on a wall that recesses over fireplace,the TV must be at least 12 inches from the top of the fireplace glass viewing area. At 12 inches above the fireplace viewing area, maximum possible recess is 3 3/4 inches.A deeper recess will interfere with required clearances to venting. Maximum possible recess increases at<12 inches above the viewing area when venting is offset(as shown in diagram below). j Max 33/" N Keep Min 4" Clear . . ' a NOTE:Vent clearances must be maintained. See "General Clearances" section for details. RE( hEIVED 09/01/2022 28 ASPEN BUILDING DEPARTMENT Access Panel An access panel is not required(see notes below for exception),but it is highly recommended. It allows for access to the fireplace's gas and electrical components for servicing. NOTE: An access panel, or some other form of clear access, is required for power vented fireplaces. For servicing purposes, the power vent control box (located at the fireplace) must be easily accessible in a way that does not require removal of the fireplace glass. Access Panel Size and Location Recommendations: • Minimum of 10 inches x 10 inches in size • Located within 36 inches of the pilot to the side or back of the fireplace(see"Routing the Gas Line") The size and location of the access panel may vary, but in all cases, it must allow the technician to comfortably access and service the fireplace's gas and electrical components. These components are attached to the pilot on a flexible gas line and can be moved within 36 inches of the pilot(located at the center front of the burner). For ease of access, move the fireplace's gas and electrical components as close to the access panel as possible. If there is any distance between the access panel and the gas and electrical components, the access panel size must be increased accordingly. Prior to installation, fireplace dealers/installers should work with the owner, builder, project architects and/or interior designers to determine the best size and location of their access panel. If an access panel cannot be incorporated, the alternative method of servicing the gas and electrical components is though the fireplace. This procedure requires removing the glass panel(s) and interior design media, and lifting the grill, burner, and bottom pressure release valve.This will increase service time and difficulty.An access panel is always preferred.Fireplace dealers/installers are advised to consult with their clients regarding the advantages and disadvantages of each service option. NOTE: If local code requires an access panel,defer to local code requirements. Chase Area Minimum To ensure the convective heat within the chase passively moves to the heat release at an optimal rate, all parts of the interior of the chase must at least the same size as the fireplace heat release(see"Heat Release"section to determine your model's required heat release size)at size at any given point.To determine if your chase meets this requirement,use the following equation at the narrowest part of the chase. Chase Area=(Chase Length x Chase Depth)—(Area of the Pipe) Length Area of the Pipe: 4"x6"venting=28.27 in2 , 5"x8"venting=50.27 in2 3"x5"venting*=19.63 in2 O J' O *Used for Power Venting only �,.o u _ -11 If the heat release is split into 25/75 portions due to an oversized ledge, the " Radius chase only needs to be the size of 75%of the heat release because 25%of the heat is already being released at the ledge (see "Ledge Detail" section below Top View for details). Fireplace Chase(Top View) RECEIVED 09/01/2022 29 ASPEN BUILDING DEPARTMENT Recessed Partial Ledge A ledge over the top of a fireplace that is less than 24 inches from the top of the fireplace viewing area must maintain a minimum of 12 inches from the top of the viewing area to the bottom of the building material. Entire structure must be non- combustible (framing and finish). If ledge surface area exceeds the values shown in the chart below, the heat release must be divided between the ledge and the chase ceiling: 25%at the ledge and 75%at the chase ceiling.This is referred to as an oversized partial ledge(see diagram below). Fireplace Series Maximum Ledge Surface Area 40 75* A x B<_220 sq. in. (includes 31H) 90-130* A x B<_340 sq. in. I 1 7 l 171 150-170 A x B<410 sq. in. 200 A x 6<_520 sq. in. I — 1I BB 250 A x B<_580 sq. in. *Includes Curve&Island and 31 H Series Fireplaces A=ledge depth,B=ledge width(Top View) Oversized Partial Ledge PThC Heat R (all on 1 side elease or split between sides) Keep area clear from obstruction for 25%Heat Release air circulation (all on 1 side or split between sides) Non-combustible framing&finish n p NI uI I i• i Oversized Partial Recessed Ledge Detail NOTE: Chase area minimum requirements must be met throughout the entire fireplace chase. See "Chase Area Minimum"section above for details. RECEIVED 09/01/2022 30 ASPEN BUILDING DEPARTMENT Structural Weight Support The fireplace must not carry any structural weight. The framing must be supported by another surface. Consult with the project structural engineer and refer to your local building codes for proper wall support. The following drawing shows a recommended approach to this type of installation. Please note that these drawings are not to scale. All fireplace drawings with correct dimensions are available on the Ortal website. SAMPLE CROSS BRACING I j MTL. STUD BRACING TYP @32" O.C. ATTACHED TO STRUCTURE • • TYP 16" O.C. • • • • • • • • • • • • • SAMPLE HEADER BEAM • CONTINUOUS BOX • • HEADER • • e xxx ee e T A RECEIVED 09/01/2022 31 ASPEN BUILDING DEPARTMENT Step-by-Step Chase Construction The following checklist is a simplified overview of typical chase construction for a built-in fireplace installation. This list is not exhaustive and does not supplement thorough review of the installation manual. Step 1 BUILD BACK AND SIDE WALLS O Frame the back and side walls according to framing requirements. O Build the platform(if necessary)to the desired height and install inside fireplace chase. ■ Platform must be stable and able to bear the full weight of the fireplace. Platform can be constructed out of wood,concrete, metal,or any other solid materials. Material is not required to be non-combustible. Step 2 INSTALL FIREPLACE AND VENTING, RUN GAS AND ELECTRICAL O Install the fireplace and venting. This must be completed by an authorized Ortal dealer(unless otherwise authorized by Ortal with written approval). O Move the gas valve and receiver unit to the designated access panel location. If the fireplace will not have an access panel, keep gas valve and receiver unit directly underneath the fireplace. O Run gas and electric to the gas valve and receiver unit location. Step 3 BUILD FRONT WALL O Install front chase wall: ■ Build front wall according to framing requirements. ■ Stand up the front wall and move into place. ■ Secure front wall to the rest of the chase structure. O Cover the exterior of each wall (sides and front, and back if applicable depending on your design)with 5/8"Type X Drywall(or equivalent)and seal gaps with a non-combustible fire sealant. NOTE:5/8"Type X Drywall(or equivalent)is not required on the exterior portion of an insulated outside-facing wall. O Check to make sure constructed chase meets heat release and air intake(if applicable)requirements. Step 4 APPLY FINISHES 0 Apply finishes and install accessories,following all clearances and building requirements. O Ensure furniture and other combustible materials maintain a minimum 36 inches of clearance directly in front of the fireplace viewing area for both front and side viewing areas(as applicable). RECEIVED 09/01/2022 32 ASPEN BUILDING DEPARTMENT Finishing The following diagrams show various finish applications. Diagrams apply to both combustible and non-combustible finish material. IMPORTANT NOTES: • All recessed installations must comply with applicable maximum overhang limit and side wall clearances. See "Maximum Overhang Depth"and"Clearance to a Side Wall"sections for details. • No material is permitted to extend past the metal lip surrounding the fireplace viewing area.This area must be unobstructed to allow the heat barrier and inside glass panel to be removable. • MANUFACTURED STONE: A minimum 2-inch recess is suggested. Consult stone manufacturer for clearance requirements. • 5/8"DensGlass®Fireguard®Sheathing is an approved 5/8"Type X Drywall equivalent.This may be necessary for use with heavier finishes. WARNING:Wood finish or floor/hearth extension may dry out,crack,warp or become discolored over time. Consult with floor manufacturer for required clearances to a heat source. Flush Installation Diagram applies to both combustible and non-combustible finish material. Keep Min 4" Clear T Y4 "MIN ® . . ® . . ,e �� . B. Tole p RECEIVED 09/01/2022 33 ASPEN BUILDING DEPARTMENT Recessed Installation Diagram applies to both combustible and non-combustible finish material.The finish must maintain at least a 1/8"clearance to the fireplace. Keep Min 4"Clear '\1' • I a %4"MIN %8"MIN • %8"MIN .o . • 1/4"MIN Y � Maximum Overhang Depth Overhang depth of a recessed fireplace must not exceed 12 inches. Overhang depth is measured from the edge of the fireplace lip to the out-most part of the wall (including finish material). Side overhang has no limit. Finish material on the underside of the overhang may be combustible or non-combustible. Bottom recess(or"hearth extension")has no minimum or maximum depth requirement. If bottom recess depth exceeds 12 inches, ensure the structure is capable of supporting the weight of a fireplace technician for servicing. Front(Long Side)Overhang Side (Short Side) Overhang N. om M. 12" MAX If NO MAX - -. Max RECEIVED 09/01/2022 34 ASPEN BUILDING DEPARTMENT Venting General Vent Requirements The fireplace operates using a direct vent system and requires co-axial direct vent pipe.The fireplace must be properly connected to an approved vent system.Venting is not provided with the fireplace and must be sourced from one of the approved vent manufacturers mentioned in the table below. Proper installation, use, and maintenance of venting is determined by and can be acquired from the vent manufacturer. Vent Requirements Fireplace Direct Vent Type Vent Size Approved Vent Manufacturers Series Passive Vent 4x6 co-axial direct vent pipe Olympia:Ventis (standard) (4"interior,6 5/8"exterior) DuraVent: Direct Vent Pro 40 ICC: EXCELDirect 60 Enervex Power Vent 4x6 co-axial direct vent pipe BDM: Pro-Form Direct Vent System 75 (optional) (4"interior, 6 5/8"exterior) Selkirk: Direct-Temp System 31H Ortal Power Vent" 3x5 co-axial direct vent pipe DuraVent: CVS line (optional) (3"interior, 5"exterior) Passive Vent 5x8 co-axial direct vent pipe Olympia:Ventis 110 (standard) (5-inch interior, 8-inch exterior) DuraVent: Direct Vent Pro 120 - ICC: EXCELDirect 130 Enervex Power Vent 5x8 co-axial direct vent pipe BDM: Pro-Form Direct Vent System 150 (optional) (5-inch interior, 8-inch exterior) Selkirk: Direct-Temp System 170 200 250 Ortal Power Vent" 3x5 co-axial direct vent pipe DuraVent: CVS line (optional) (3-inch interior, 5-inch exterior) Passive Vent 4x6 co-axial direct vent pipe Olympia:Ventis (standard) (4"interior,6 5/8"exterior) DuraVent: Direct Vent Pro Island 70 ICC: EXCELDirect Enervex Power Vent 5x8 co-axial direct vent pipe BDM: Pro-Form Direct Vent System (optional) (5-inch interior, 8-inch exterior) Selkirk: Direct-Temp System (see note below) Passive Vent 5x8 co-axial direct vent pipe Olympia:Ventis (standard) (5-inch interior, 8-inch exterior) DuraVent: Direct Vent Pro Curve ICC: EXCELDirect Island 130 Enervex Power Vent BDM: Pro-Form Direct Vent System (optional) 5x8 co-axial direct vent pipe Y (op ) (5-inch interior, 8-inch exterior) Selkirk: Direct-Temp System (see note below) *Power Vent: a fan-assisted direct vent system that boosts airflow for vent configurations with too much constriction. Review"Vent Configurations"section to determine if your fireplace needs a power vent. See the Ortal Power Vent Manual for more details on power venting. NOTE:The Curve and Island series fireplaces are not permitted for use with an Ortal Power Vent. TERMINATION CAP NOTE:Low Profile Vertical Termination Cap and Sconce Horizontal Termination Cap can negatively impact flame appearance and are not recommended for use with the fireplace. WARNING: Do not combine vent components from different vent manufacturers. Please follow the manufacturer's instructions for vent system installation. RECEIVED 09/01/2022 35 ASPEN BUILDING DEPARTMENT Vent Configurations The following sections provide information for calculating vent configuration distances and elbows.For vent configurations that cannot conform to these guidelines, consider Ortal's Power Vent System, or contact Ortal for assistance. Power Vent information can be found in the Power Vent Installation Manual. Please consider the following guidelines when determining vent configuration: Elbows • Maximum Elbows: Up to four 90°elbows can be used in the vent configuration.Two 45°elbows=one 90°elbow. • 45° Vertical Offset Exception: Two 45° elbows in the vertical plane with a diagonal run in between is equal to 0 elbows. They are not counted with other elbows in the vent configuration.This offset exception is applicable immediately on the top of the fireplace and anywhere else within the vent configuration. The diagonal run between the two 45°elbows must be included when calculating vertical and horizontal distances. • 45° Horizontal Offset:Two 45° elbows that begin and end in the horizontal plane,with a diagonal run in between, is equal to one 90° elbow.Additionally,3 feet must be reduced from the total allowable horizontal run. The diagonal run between the two 45°elbows must be included when calculating vertical and horizontal distances • Exceeding two 90° Elbows: For more than two 90° elbows, the minimum total vertical rise is 6 feet for 90-250 models. This does not apply to 40-75 models. • Flat 90° Elbows: For every flat 90° elbow(a 90° elbow that stays in the horizontal plane), 6 feet must be reduced from the total allowable horizontal run. Up to two flat elbows are allowed. ■ Example: If max allowable horizontal run is 24 feet and 1 flat elbow is added, max run is reduced to 18 feet. • 3rd 90° Elbow in the Vertical Plane:The 3rd elbow in the vertical plane reduces 3 feet from total allowable horizontal run. Do not include flat elbows when determining which 90° elbow in your configuration is 3rd in the vertical plane. Exception: If the 3rd 90° elbow in the vertical plane turns the vent direction from horizontal to vertical, the total allowable horizontal run does not require a 3-foot reduction. Diagonal Runs • Calculating Diagonal Runs (D): Diagonal (45°) vent runs have an equal combination of vertical and horizontal aspects. To include diagonal portions of your desired vent configuration when determining overall vent limitations, divide the diagonal distance in half.Add this value to the total vertical rise and total horizontal run distances in your vent configuration. Include these values when utilizing the Vent Configuration Tables below. • Example:6 feet diagonal run=3 feet vertical rise&3 feet horizontal run Other • V Minimum:This is the minimum amount of vertical rise required before the first completely horizontal(not diagonal)run. • Any vent configuration that does not meet these parameters requires Ortal's review and approval. RECEIVED 09/01/2022 36 ASPEN BUILDING DEPARTMENT Vertical lilt Termination \ Cap Horizontal Termination > 3rd 90°Elbow in '�� Cap the Vertical Plane 90°Elbows �90°Elbow N iii r >��90°Elbow t�45°Elbow j Flat 90°�� E + Elbow 45°Vertical Offset + (elbows=0) c + �90°Elbow 45° o ' ' Elbow > /1 E p � ii E `o SI. o TERMINATION CAP NOTE: Low Profile Vertical Termination Cap and Sconce Horizontal Termination Cap can negatively impact flame appearance and are not recommended for use with the fireplace. Allowable Maximum Horizontal Runs Series 40-75 Series 110-130 Series 150-170 Series 200 Series 250 (includes 31H) V minimum=oft V minimum=3ft V minimum=3ft V minimum=6ft V minimum=6 ft Vertical Max Vertical Max Vertical Max Vertical Max Vertical Max (V) Horizontal Horizontal Horizontal Horizontal Horizontal (H) (V) (H) (V) (H) (V) (H) (V) (H) 0 ft 6ft _ N/A N/A N/A N/A N/A N/A N/A N/A 1 ft 12 ft N/A N/A N/A N/A N/A N/A N/A N/A 3 ft 21 ft _ 3ft 12 ft 3ft 9 ft N/A N/A N/A N/A 6 ft I 24 ft 9 ft 30 ft _ 9 ft 30 ft I 9 ft 30 ft 9 ft 19 ft 9 ft 8 ft 12 ft 30 ft 12 ft 30 ft 12 ft 30 ft 12 ft 19 ft 12 ft 11 ft 15 ft 24 ft 15 ft 30 ft 15 ft 30 ft 15 ft 19 ft 15 ft 12 ft 18 ft 21 ft _ 18 ft 27 ft 18 ft 30 ft 18 ft 19 ft 18 ft 12 ft 21 ft 18 ft 21 ft 24 ft 21 ft 27 ft 21 ft 19 ft 21 ft 10 ft 24 ft 15 ft 24 ft 21 ft 24 ft 24 ft 24 ft 19 ft 24 ft 8 ft 27 ft 12 ft _ 27 ft 21 ft 27 ft 21 ft 27 ft 19 ft 27 ft 7 ft 30 ft 12 ft 30 ft 21 ft 30 ft _ 21 ft 30 ft _ 19 ft 30 ft _ 5 ft 33 ft 12 ft 33 ft 21 ft 33 ft 15 ft 33 ft 19 ft 33 ft 4 ft 36 ft 4 ft 36 ft 12 ft 36 ft 15 ft 36 ft 19 ft 36 ft Oft 44 ft 0 ft 44 ft 0 ft 44 ft 0 ft 44 ft 0 ft N/A N/A CHART NOTE: Do not include the space elbows take up when calculating your vertical and horizontal distances. RECEIVED 09/01/2022 37 ASPEN BUILDING DEPARTMENT Examples using a 110 Front q V3=2ft . et11%%600 OK\ 3rd 90° Elbow '� V2=3ft in the Vertical Plane 'r(c V2=4ft Flat �� 2nd 90°Elbow in • 90° Elbow ' the Vertical Plane 2nd 90°Elbow --111% 1st 90°Elbow 1st 90° Elbow .64. 4;.--,,,/10 S V1 =3ft V1 = 3ft ' `aAi 11 - 1110 V=V1+V2+V3 \I1 V=V1+V2 I= ' H=H1+H2+3rd 90° elbow H=H1+H2+6ft(for flat elbow) V=3ft+4ft+ 2ft= 9ft V=3ft+ 3ft=6ft H = 5ft+ 4ft+3ft= 12ft H =5ft+2ft+6ft= 13ft t‘ "I D2= 6ft 0 Horizontal I't Offset 0* 4 (2nd 90° 1st 90° Elbow ' Elbow) V2 = 2ft %1‘;'...���� D1 =4ft IP -40 Vertical O li ffset V1 =6ft ci, gl V=(1/2 D1)+V2+(1/2 D2) V=V1 H=(1/2 D1)+H2+(1/2 D2)+3ft(for horiz. offset)+H4 H=H1 V=2ft+2ft+3ft=7ft V=6ft RECEIVED H =2ft+2ft+3ft+ 3ft+ 5ft= 15ft H =3ft 09/01/2022 38 ASPEN BUILDING DEPARTMENT Vent Restrictors A vent restrictor is a metal plate that reduces the flow of exhaust evacuating the fireplace.A restrictor is only necessary when the flame is receiving too much oxygen. Various-sized restrictors are supplied with every fireplace. See instructions below to determine which restrictor, if any, is recommended for your fireplace. Restrictor Sizing Guidelines The restrictor sizing tables in this section determine the recommended restrictor for your vent configuration.These tables show Ortal's recommendations only.The Environment, gas type and other factors may affect the best restrictor choice. How to use the "Recommended Restrictor"tables: 1. Find the total vertical rise in your vent configuration along the y-axis. 2. Find the horizontal run in your vent configuration along the x-axis. 3. Follow the desired rise and run values within the table until they meet. This value is the recommended restrictor size (in inches)for your vent configuration. Legend: Restrictor Sizes: X:Vent configuration is not allowed. Power vent required. • 20mm(0.79") 0: No restrictor required. • 30mm(1.18") Numbers other than 0: Represents the recommended restrictor(by width). • 40mm(1.57") • 50mm(1.97") • 70mm(2.75") • 85mm(3.35") • Space Creator Restrictor-Passive Direct Vent • Space Creator Restrictor-Power Vent NOTE: Space Creator models come with a special restrictor specific to the Space Creator Series. It is not required to use any other available restrictor. Series 40-75 Fireplaces (includes 31H) V Minimum=0 Feet 44' 1.97" X X X X X X X X X X X 33' 1.97" 1.97" 1.97" 1.97" 1.57" X X X X X X X 30' 1.97" 1.97" 1.97" 1.97" 1.57" X X X X X X X 27' 1.97" 1.97" 1.97" 1.97" 1.57" X X X X X X X 24' 1.97" 1.97" 1.97" 1.97" 1.57" 1.18" X X X X X X a) y ▪ 21' 1.97" 1.97" 1.97" 1.97" 1.57" 1.18" 0 X X X X X ✓ aa) 18' 1.97" 1.97" 1.97" 1.57" 1.57" 1.18" 0.79" 0 X X X X 70, 15' 1.57" 1.57" 1.57" 1.57" 1.18" 1.18" 0.79" 0 0 X X X E > 12' 1.57" 1.57" 1.57" 1.18" 1.18" 0.79" 0 0 0 X X X . 9' 1.57" 1.57" 1.18" 1.18" 0.79" 0 0 0 0 X X X 0 1- - - 6' 1.18" 1.18" 0.79" 0.79" 0 0 0 0 0 X X X 3' 0 0 0 0 0 0 0 0 X X X X 0' 0 0 0 0 0 X X X X X X X - 0' 3' 6' 9' 12' 15' 18' 21' 24' 27' 30' 33' Horizontal Vent Run RECEIVED 09/01/2022 39 ASPEN BUILDING DEPARTMENT Series 110-130 Fireplaces V Minimum=3 Feet 44' 2.75" X X X X X X X X X X X 33' 2.75" 1.97" 1.97" 1.97" X X X I X X X X X 30' 2.75" 1.97" 1.97" 1.97" X X X X X X X X 27' 2.75" 1.97" 1.97" 1.97" X X X X X X X X 24' 2.75" 2.75" 2.75" 1.97" X X X X X X X X o Nl E 21' 2.75" 2.75" 1.97" 1.97" 1.57" 1.18" X X X X X X a�i 18' 1.97" 1.97" 1.97" 1.57" 1.57" 1.18" 0 X X X X X 15' 1.97" 1.97" 1.97" 1.57" 1.57" 1.18" 0 0 X X X X •L > 12' 1.97" 1.97" 1.57" 1.57" 1.18" 1.18" 0 0 X X X X :° 9' 1.57" 1.57" 1.18" 1.18" 0 0 0 0 0 X X X 0 i- 6' 1.18" 0 0 0 0 0 0 I 0 0 X X X 3' 0 0 0 0 0 X X X X X ' X X 0' X X X X X X X X X X X X 0' 3' 6' 9' 12' 15' 18' 21' 24' 27' 30' 33' Horizontal Vent Run Series 150-170 Fireplaces V Minimum=3 Feet 44' 2.75" X X X X X X X X X X X 33' 2.75" 2.75" 2.75" 1.97" X X X X X X X X 30' 2.75" 2.75" 2.75" 1.97" X X X X X X X X 27' 2.75" 2.75" 2.75" 1.97" X X X X X X X X 24' 2.75" 2.75" 2.75" 1.97" 1.57" X X X X X X X a> N E 21' 2.75" 2.75" 1.97" 1.57" 1.57" 1.18" 1.18" X X X X X aii 18' 1.97" 1.97" 1.97" 1.57" 1.18" 0 0 0 X X X X u 15' 1.97" 1.97" 1.57" 1.57" 1.18" 0 0 0 X X X X •i > 12' 1.97" 1.97" 1.57" 1.18" 1.18" 0 0 0 X X X X ra 9' 1.57" 1.57" 1.18" 1.18" 0 0 0 0 X X X X 0 I- 6' 1.18" 1.18" 0 0 0 0 0 X X X X X 3' 0 0 0 0 X X X X X X X X 0' X X X X X X X X X X X X 0' 3' 6' 9' 12' 15' 18' 21' 24' 27' 30' 33' Horizontal Vent Run RECEIVED 09/01/2022 40 ASPEN BUILDING DEPARTMENT Series 200 Fireplaces V Minimum=6 Feet 44' 2.75" X X X X X X X X X X X 33' 2.75" 1.97" 1.97" X X X X X X X X X 30' 2.75" 1.97" 1.97" 1.97" X X X X X X X X 27' 2.75" 1.97" 1.97" 1.97" X X X X X X X X a� 24' 2.75" 1.97" 1.97" 1.57" 1.18" X X X X X X X U) ▪ 21' 2.75" 1.97" 1.57" 1.18" 1.18" 1.18" 0 X X X X X a m 18' 1.97" 1.97" 1.57" 1.18" 1.18" 0 0 0 X X X X c`,i 15' 1.97" 1.97" 1.57" 1.18" 1.18" 0 0 0 X X X X > 12' 1.57" 1.57" 1.57" 1.18" 0 0 0 0 X X X X .3 9' 1.57" 1.57" 1.18" 1.18" 0 0 0 0 X X X X 0 i- 6' 0 0 0 0 0 0 0 X X X X X 3' X X X X X X X X X X X X 0' X X X X X X X X X X X X 0' 3' 6' 9' 12' 15' 18' 21' 24' 27' 30' 33' Horizontal Vent Run Series 250 Fireplaces V Minimum=6 Feet 44' X X X X X X X X X X X X 36' 2.75" X X X X X X X X X X X 33' 2.75" 1.97" X X X X X X X X X X 30' 2.75" 1.97" X X X X X X X X X X 27' 1.97" 1.97" 1.97" X X X X X X X X X 24' 1.97" 1.97" 1.97" X X X X X X X X X m y iY 21' 1.97" 1.57" 1.57" 1.18" X X X X X X X X • 18' 1.97" 1.57" 1.57" 1.18" 1.18" X X X X X X X c`ai 15' 1.57" 1.57" 1.18" 1.18" 0 X X X X X X X f > 12' 1.57" 1.18" 1.18" 1.18" X X X X X X X X 7a 9' 1.18" 1.18" 0 X X X X X X X X X 0 i- 6' 0 0 X X X X X X X X X X 3' X X X X X X X X X X X X 0' X X X X X X X X X X X X 0' 3' 6' 9' 12' 15' 18' 21' 24' 27' 30' 33' Horizontal Vent Run RECEIVED 09/01/2022 41 ASPEN BUILDING DEPARTMENT Vent Clearances The following clearances apply to the vent system regardless of vent manufacturer. 3 in. 1 in. 1 in. 1 in. 3 in. .•. or 1 in. Vent Clearances Sides: 1 inch Applies to entire circumference when venting is oriented vertically. *Top: 3 inches Applies to venting with any amount of horizontal aspect. Bottom: 1 inch Applies to venting with any amount of horizontal aspect. *Exception: Wall thimble top clearance to any material is 1 inch. RECEIVED 09/01/2022 42 ASPEN BUILDING DEPARTMENT Termination Horizontal Termination Clearance Diagram Measure vertical clearances from this surface. VE / H. �1 A H. 1411 Measure horizontal clearances (1� I 44 �% from this surface. N:i -11. „ • rir. _us(3,T) I - � � ► .7_>4� M ` \ L `—'��'� Al Allik. ,• , Gr Ek K Electrical K Service ill —Amp, >Horl C ❑V =VENT TERMINAL 0 =AIR SUPPLY INLET r =AREA WHERE TERMINAL IS NOT PERMITTED ig Location Country I Minimum Clearance Description J. Clearance above grade,veranda,porch,deck,or balcony. A US& 12 inches NOTE:On private property where termination is less than 7 feet above a sidewalk,driveway, Canada deck,porch,veranda,or balcony,use of a listed cap shield is suggested. US 50,000 BTU:9 inches Clearance to an operable window or door. B >50,000 BTU: 12 inches Canada 12 inches NOTE:Zero clearance to an inoperable window or door. 24 inches Vertical clearance to a ventilated soffit located above the vent termination. US& C Canada 18 inches Vertical clearance to an unventilated soffit located above the vent termination. 42 inches Vertical clearance to vinyl clad soffits and below electrical service. D Canada 9 inches Clearance to an outside corner. E Canada 6 inches Clearance to an inside corner. US N/A Not to be installed above a gas meter/regulator assembly within 3 feet(90 cm)horizontally F Canada 3 feet from the center-line of the regulator. US& G Canada 3 feet Clearance to gas service regulator vent outlet. Clearance to a non-mechanical air supply inlet to the building or the combustion air inlet to US 9 inches any other appliance. NOTE:Termination in a covered alcove space(spaces open only on one side and with an H overhang)are permitted with the dimensions specified for vinyl or non-vinyl siding and soffits. 1.There must be 3 feet minimum between termination caps. 2.All mechanical air intakes Canada 12 inches within 10 feet of a termination cap must be a minimum of 3 feet below the termination cap.3. All gravity air intakes within 3 feet of a termination cap must be a minimum of 1 foot below the termination cap. Clearance to a mechanical(powered)air supply inlet. US 3 feet NOTE:Termination in a covered alcove space(spaces open only on one side and with an overhang)are permitted with the dimensions specified for vinyl or non-vinyl siding and soffits. I 1.There must be 3 feet minimum between termination caps. 2.All mechanical air intakes within 10 feet of a termination cap must be a minimum of 3 feet below the termination cap.3. Canada 6 feet All gravity air intakes within 3 feet of a termination cap must be a minimum of 1 foot below the termination cap. Clearance above paved sidewalk or a paved driveway located on public property. J' US& NOTE:On private property where termination is less than 7 feet above a sidewalk,driveway, Canada 7 feet deck,porch,veranda,or balcony,use of a listed cap shield is suggested. *a vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings. Clearance from sides of electrical service. K Canada 6 inches NOTE: Location of the vent termination must not interfere with access to the electrical service. Clearance above electrical service. L US& 12 inches NOTE: Location of the vent termination must not interfere with access toRE srtE Iv '"D Canada 9 service. 09/01/2022 43 ASPEN BUILDING DEPARTMENT M N ØPLfd1 Q Covered Alcove:spaces open only on one side and with an overhang Horizontal Termination Clearances Continued: Covered Alcove Application Location Country Minimum Clearance Description Clearance under non-vinyl veranda,porch,deck,balcony,or overhang. NOTE:Termination in a covered alcove space is permitted with the dimensions specified. O US& 1.There must be 3 feet minimum between termination caps. Q M Canada 16 inches 2.All mechanical air intakes within 10 feet of a termination cap must be a minimum of 3 ✓ feet below the termination cap. 3. All gravity air intakes within 3 feet of a termination cap must be a minimum of 1 foot a below the termination cap. US& 6 inches Non-vinyl sidewalls. pN Canada 12 inches Vinyl sidewalls. G• P Canada 8 feet Alcove height. cc US& See table below. Alcove width(dependent on number of caps in the space). Canada U R Canada See table below. Alcove depth(dependent on number of caps in the space). #Vent Caps QMINIMUM RMAXIMUM 1 vent cap 3 feet 2 x QACTUAL 2 vent caps 6 feet 1 x QACTUAL 3 vent caps 9 feet 2/3 X QACTUAL 4 vent caps 12 feet 1/2 X QACTUAL QMIN=#vent caps x 3 RMAX=(2/#vent caps)X QACTUAL HORIZONTAL TERMINATION CAP CLERANCES-NOTES: • If exterior walls are finished with vinyl siding, it is required that a vinyl protector kit be installed. • Vent system termination is not permitted in screened porches. • Vent system termination is permitted in porch areas with two or more sides open. You must follow all side walls, overhang and ground clearances as stated. • Termination caps may be hot. Consider their proximity to doors or other traffic areas. TERMINATION CAP NOTE: Sconce Horizontal Termination Cap can negatively impact flame appearance and are not recommended for use with the fireplace. RECEIVED 09/01/2022 44 ASPEN BUILDING DEPARTMENT Vertical Termination Clearance Diagram Minimum Height From Roof To Lowest Discharge Opening Staggered Termination Caps HORIZONTAL A B _ OVERHANG 24 INCHES 6 in. (minimum) 18 in. minimum 2 FT.MIN. MIN. up to 24 in. LOWEST VERTICAL DISCHARG: WALL 24 in.and over 0 in. minimum MOPENING GAS VENT TERMINATION N CAP ®X Gas,Wood or Fuel — Oil Terrain to ion Cap ROOF PITCH IS X112 H MIN.)-MINIMUM / HEIGHT FROM B ROOF TO LOWEST DISCHARGE 1—I J OPENING Gas Roof Pitch H(Min.)Ft. Termination II II II II I Flat to 6/12 1.0* Over 6/12 to 7/12 1.25* Cap** II II I II 11 II III Over 7/12 to 8/12 1.5* I II II II II Over 8/12 to 9/12 2.0* __II II II II I Over 9/12 to 10/12 2.5* II II II II Over 10/12 to 11/12 3.25 Over 11/12 to 12/12 4.0 JI II II II I Over 12/12 to 14/12 5.0 Over 14/12 to 16/12 6.0 * if using decorative cap cover(s),this distance Over 16/12 to 18/12 7.0 may need to be increased. Refer to the Over 18/12 to 20/12 7.5 installation instructions supplied with the Over 20/12 to 21/12 8.0 decorative cap cover. ** In a staggered installation with both gas and *H min. may vary depending on regional wood or fuel oil terminations,the wood or fuel oil snowfall. Refer to local codes. termination cap must be higher than the gas termination cap. Notes: 1. Maintain a minimum of 2 feet clearance between edge of vertical termination and perpendicular wall. 2. If terminating near window, keep minimum of 2 feet clearance between window and vent termination. 3. All mechanical air intakes(such as an Enervex power vent)within 10 feet of a termination cap must be a minimum of 3 feet below the termination cap. 4. All gravity air intakes within 3 feet of a termination cap must be a minimum of 1 foot below the termination cap. NOTE:This chart does not apply to a chimney shroud application.See the"Chimney Shroud"section on the next page for more information. TERMINATION CAP NOTE:A Low Profile Vertical Termination Cap can negatively impact flame appearance and is not recommended for use with the fireplace. RECEIVED 09/01/2022 45 ASPEN BUILDING DEPARTMENT Chimney Shroud Top Open Keep a minimum 6-inch clearance around the diameter of the cap's side edge and extending above and below the cap. I I All surfaces of the chimney shroud ///ii/////� exposed to the jbe non-combustible.terminancap must / ////// j Min. 6" II Al Min Min.l '� 0 Venting must extend /AVM/AA j / A'�min. 6' from the roof jA before start of III Min. 6" termination cap Sides Open Keep a minimum 6-inch clearance around the diameter of the cap's side edge, and a minimum 10-inch clearance above the top of the cap. For openings in the shroud, make sure to allow for enough air flow space to release the exhaust gases and allow the vent to operate properly. All surfaces of the chimney shroud exposed to the /iiiiiiiiiiiiiiiiiiiiiiiiiii/ termination cap must / iiiiiiiiiiiiiiiiiiiiiiiiiA Min. 10 be non-combustible. %' A Al Min. 6" I I I I I //.// / must extend - ' m Venting f om the roof Min. 6" jIII A before start of termination cap Vent Installation Venting must be installed to meet the requirements as detailed in the following sections in conjunction with the vent system manufacturer's installation instructions.Venting must be supported by the structural surrounding and not by the fireplace.Each offset (elbow)must be strapped to reduce movement or possible disconnection. The first section of venting must be secured to the fireplace starter collar with a minimum of 3 sheet metal screws no longer than 1/2". DO OT use silicone to seal the sections. If sealing is required by the vent manufacturer or local code, use Mil-Pac sealant. WARNING: Do not combine vent components from different vent manufacturers. Please follow the manufacturer's instructions for vent system installation. RECEIVED 09/01/2022 46 ASPEN BUILDING DEPARTMENT Vent Maintenance Regular inspection of the vent system by a qualified service technician is recommended every six months.The following maintenance routing is recommended: • Inspect for excessive condensation,e.g.,water droplets forming in the inner lining,and subsequently dripping from the joints. This can cause corrosion in the system. • Check for corrosion in areas exposed to the elements. Components with rust spots or holes must be immediately replaced. • Ensure that there is no foreign material in the vents.Survey by removing the cap and shining a light down the vent. • If possible, check all vent joints to make sure nothing has been disturbed or loosened. Co-Axial to Co-Linear Conversion This section explains how the fireplace can be inserted into an existing solid fuel burning fireplace chimney by converting the co-axial venting to co-linear. IMPORTANT NOTES: • Co-linear portion of vent system may only be installed within a solid-fuel burning masonry fireplace and masonry chimney.It is prohibited to install co-linear in any other setting. • The fireplace must be vented vertically to the outside and must use one of the approved co-linear flexible ducting systems or a co-axial flexible ducting system. • Air intake(as applicable)and heat release is still required per installation guidelines(even when venting through a chimney). All other building requirements still apply. • Restrictor use is not required when using co-linear venting. WARNINGS: • If the vent system of this appliance is disconnected for any reason, the vent and air intake systems must be properly reassembled and resealed before this appliance is put into use. • Proper installation of the vent system,as required in this manual, is vital to the performance of this appliance.Oversights or failure to conform to all installation requirements will void the applicable warranty. • This appliance must be properly connected to a venting system in accordance with the Ortal's installation instructions. Operation of this appliance when not connected to a properly installed and maintained venting system can result in carbon monoxide(CO)poisoning and possibly death. • Co-linear flexible aluminum venting must be professionally inspected periodically for corrosion and damage and replaced when necessary. If the installation does not allow for future inspection or replacement of the flexible aluminum venting,then stainless steel vent liners should be used. • The appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance. The plan to install a gas fireplace inside an existing solid fuel burning fireplace chimney must include inspection and cleaning of the fireplace cavity and the entire chimney system.The chimney top,especially masonry chimneys and wood framed chimney tops must be inspected,and the top surface must be repaired or replaced,if necessary.Unlined chimney flues are the most vulnerable to mortar corrosion and damage.These flues must be inspected,and repair must be done before dropping the flex vent liner for this Insert If you encounter a badly deteriorated or completely damaged firebox,do not proceed.These damaged structures must be reviewed by structural Engineers and Local Building Code officials must approve the repair work prior to this Insert being installed in such a damaged cavity. Series Vent Size Adapter Split Pipe Size Termination Cap (BDM or equivalent*) (BDM or equivalent*) 75 4"x6" 4"x6"to 3"x3"(DVR6-A33) 3"x3" 3"x3"(PV3-VCS33B) (includes 31H) 110/110H 5"x8" 5"x8"to 4"x3"(DVR8-A34) 4"x3" 4"x3"(PV3-VCS34B) 130/130H 5"x8" 5"x8"to 4"x3"(DVR8-A34) 4"x3" 4"x3"(PV3-VCS34B) 150/150H 5"x8" 5"x8"to 4"x3"(DVR8-A34) 4"x3" 4"x3"(PV3-VCS34B) *BDM component part numbers are offered as a suggestion. Components from the following companies may also be used if they have corresponding products: Duravent,Olympia, ICC,and Selkirk. Example of Co-axial to Co-linear Appliance Adapters Example of Co-linear Terminal (BDM) (BDM) ,0111110, iii 09/01/2022 47 ASPEN BUILDING DEPARTMENT Vent Configuration • Minimum Vertical Rise: 10 feet(see diagram below) • Maximum Vertical Rise:40 feet(see diagram below) • Offsets: Two 45° offsets may be used directly on the fireplace with up to a 6-foot section between them. The minimum vertical rise starts above them(see diagram below). No other offsets are permitted in the vent configuration.Offsets are not required to have. Termination Cap IIIIIIIII I I IIIIIIII I I i di Il ilik o o I i — — D D l l D 0 D i • LI —— D HeatFlio Heat 10'Minimum Release Release -- — 40'Maximum CI II II II I II l f �00001 1 -� G: = PI 11 11 11 11 . - BE II II . II 1 -- EN =1 II II II II 1 I Co-Axial t0 --- a �. I Co-Linear' —— uryD ° u � D D � Adaptor; nn `` ' -- — i \ -- o ry u u u --- -- ol Ir n n \-. I r e i 3111 i. I I II II ! II . I \ All-- ol II II II II I _ _ 6' Minimum I a it Slde b'ie,/ 01 II II II . I 1 I EMINIMMEMITI MN pq �q III - pPgBige Fireplace O O I 1=Il ' l l Toy Vielijl�l 00000000000m00000Um00Um00 milmmim 0000 RECEIVED 09/01/2022 48 ASPEN BUILDING DEPARTMENT Gas The fireplaces are approved for use with natural gas(NG)or propane(LP)only. No other fuel types are permitted. Gas Pressures Inlet Manifold Heat Input Fireplace Burner Burner Gas Type Pressures Pressure (BTU/hr.) Orifice Sizes* Series Size Type (Inch W.C.) (Inch W.C.) . Min Max Min Max Natural Gas 7.0 10.0 3.2 10,419 23,670 650 40H70 30 Single Propane 11.0 13.0 10.9 12,841 21,073 220 60x80 70 Natural Gas 7.0 10.0 4.7 16,147 29,100 650 75 45 Single 75x65 Propane 11.0 13.0 9.5 15,627 28,118 320 31H Natural Gas 7.0 11.0 4.7 18,327 33,029 380 Front Standard 380 Back Curve 45 Double Propane 11.0 13.0 10.7 17,796 28,500 160 Front 160 Back 110 Natural Gas 7.0 11.0 5.6 22,798 37,167 1200 120 100 Single 130 Propane 11.0 13.0 10.0 25,113 35,316 380 Natural Gas 7.0 11.0 3.5 23,312 43,715 1400 150 135 Single 170 Propane 11.0 13.0 9.5 34,008 49,704 500 Natural Gas 7.0 11.0 4.5 27,467 51,277 1400 200 160 Single Propane 11.0 13.0 10.0 24,329 51,011 500 Natural Gas 7.0 11.0 4.7 21,700 52,700 1400 250 180 Single Propane 11.0 13.0 9.0 42,640 57,045 650 NOTE: It can take up to 20 minutes for the flames to turn yellow. High Altitude Requirements For elevations above 2,000 feet,fireplace shall be de-rated 4%for each 1,000 feet above sea level. RECEIVED 09/01/2022 49 ASPEN BUILDING DEPARTMENT Routing the Gas Line Correctly size and route the gas supply line from the supply regulator to the area where the access panel is located (or to the burner area if no access panel is available), as per the requirements outlined in the latest edition of the National Fuel Gas Code, NFPA 54(USA)or CAN/CSA-B1491 (Canada). 6„ The gas and electrical components are attached to the pilot on a flexible gas line and can be kept directly under the fireplace or moved to the side or back of the fireplace within ®e e e m m m e e e em0000vom_ _=. oo_ 36 inches of the pilot (located at the center front of the - burner). Gas line should be routed to the access panel area •o o °' °' •. '° •'° •'° ° (see "Access Panel" section for details). If no access panel is ° °• °• ° ° o •0 •0 •0 •0 •° • ° planned, gas line should be routed to the most accessible area 36" —�0000000-0000000 • 36" within the 36-inch radius(as shown in diagram below). A gas shut-off valve and a 12"gas flex connector are provided with every fireplace. The location of the gas shut-off valve is dependent on local codes and requirements. Check with your authority having jurisdiction for more information. 36' WARNING: The main gas valve must be installed to allow complete disconnection of the fireplace from the gas supply piping system for servicing purposes. Gas Conversion Gas conversion (NG to LP or LP to NG)can be done in the field. Gas conversion must be performed only by technicians who have specific authorization by Ortal to change these components. The conversion kit must be supplied by Ortal. Using parts from other manufacturers or having an unauthorized party performing the conversion will void your fireplace's warranty.Conversion instructions are supplied with the conversion kit. RECEIVED 09/01/2022 50 ASPEN BUILDING DEPARTMENT Gas and Electrical Components Assemblies and components are listed and described in the tables following the figure. For Series 40—170(including H) Serial#21818-28183, and Series 200-250 (included H) Serial#21818&forward G202-XRGB G203-W2ME \ ii -.j.E,V i, -_ >> 4G11 G301 G45 D23[LPG]/D36 G12 G36 G37 G19 G09 \, Z G38 G sa Z )G 34 • ._ 1 G10 ilk G07 F„ ■ - I G35 G11 En G13 1111111kV G14[LPG] /G75 \\ G 121 I I, G02 G11 G47 L. G25 Part Part Number Description Number Description D23 Orifice LPG G13 Electrode Target Type D36 Orifice NG _ G121 Main Burner Gas Fitting G02 Mertik Gas Valve _ G25 Burner Gas Tube G301 Symax Receiver G19 Pilot Gas Tube G202-XRGB Symax Wi-Fi Box G34 Spark Plug Connector G203-W2ME Symax Wi-Fi Box Cable G35 Thermocouple Connector G07 Thermocouple Block G36 OLIVE D.4 Pilot gas tube compression ring valve G09 Wire Harness for Receiver and Gas G37 Pilot gas tube fitting burner side Valve G10 Switch w. cables 180/500 mm G38 Pilot Assembly Gasket G11 Spark Wire G45 Red Cable G12 Pilot Base G58 Connection fitting 4mm One-piece G75 Thermocouple NG G47 Fitting for main line inlet to gas valve GV60 G14 Thermocouple LPG RECEIVED 09/01/2022 51 ASPEN BUILDING DEPARTMENT For Series 40—170(including H's), Serial#28183 and forward G203-W2ME G202-XRGB U.S.A \ r rieti iD G3011 0 '-' G45 \1 D23[LPG]/D36 G12 G36 G37 G19 ' G09 ASB002 G34 C G 58 U ..4 i — . — A — a= • �� G10 G07 a �" a G35 G11 MN G13 G14[LPG] /G75 \ G121 � t\ G02 G11 1 G47 ASB001 _ ,[ • G25 Part Part Number Description Number Description ASB001 Pilot Bracket ASB002 Pilot Gasket D23 Orifice LPG G13 Electrode Target Type D36 Orifice NG G121 Main Burner Gas Fitting G02 Mertik Gas Valve G25 Burner Gas Tube G301 Symax Receiver G19 Pilot Gas Tube G202-XRGB Symax Wi-Fi Box G34 Spark Plug Connector G203-W2ME Symax Wi-Fi Box Cable G35 Thermocouple Connector G07 Thermocouple Block G36 OLIVE D.4 Pilot gas tube compression ring valve G09 Wire Harness for Receiver and Gas G37 Pilot gas tube fitting burner side Valve G10 Switch w.cables 180/500 mm G38 Pilot Assembly Gasket G11 Spark Wire G45 Red Cable G12 Pilot Base G58 Connection fitting 4mm One-piece G75 Thermocouple NG G47 Fitting for main line inlet to gas valve GV60 G14 Thermocouple LPG The manufacturer of Ortal's gas and electrical components is Mertik Maxitrol. For information on these components, please visit the manufacturer's website:www.mertikmaxitrol.com RECEIVED 09/01/2022 52 ASPEN BUILDING DEPARTMENT Electrical AA WARNING: Disconnect the power supply before servicing any electrical components. Electrical Requirements A duplex receptacle with two outlets(not included)must be installed in the location where the gas and electrical components will be placed,which must be to the side or back of the fireplace within 36 inches of the pilot(see diagram in"Routing the Gas Line"section). Electrical work should be performed by a qualified licensed electrician, per local code. Outlet Type Power Requirements 1 Duplex Receptacle(2 outlets) 120V, 15 amp,60Hz WARNING: Use of an AC Adapter other than the one provided with the fireplace(manufactured by Mertik Maxitrol)may render the system inoperable. NOTE:Any device that functions using the same radio frequency as the handset will be affected when remote-controlled handset is in use. Power Outage Fireplaces with a screen heat barrier and no other optional features(lights,power vent,heat control system,Wi-Fi)may be used with 4 AA batteries in the receiver in addition to the AC Adapter. If the batteries are used instead of the AC Adapter,the fireplace can operate in the event of a power outage to the building. Batteries must be replaced annually. Fireplaces with double glass heat barrier, power vent,or a heat control system may not be used with batteries. Pairing the Remote and Receiver To set up the remote-control device to operate the fireplace, follow the following guidelines to pair the remote and receiver unit on the same radio frequency. 1. Press and hold the receiver's reset button until you hear two beeps. The first beep is short, and the second beep is long. After the second beep, release the reset button. .'' RESET 2. Within the subsequent 20 seconds, press the following button depending on the mode of operation: • 10-Button Handset: Press the O button until you see the word "CONN"and a number counting up from 1 to 8 appear on the handset display.This confirms that the synchronization and data exchange are in process. • Puck Handset: Press and hold the—button approximately 4 seconds. • Wall Switch: Use the 10-button handset to synch with the receiver. Once the remote and receiver are paired,the wall switch will function normally. • MyFire App: Use the 10-button handset to synch with the receiver. Once the remote and receiver are paired,the App will function normally. 3. You will hear two short beeps confirming the connection. NOTES: • IMPORTANT:For safety/communication purposes,10-button handset must be located within 26 feet of the receiver. • If you hear one long beep,this indicates the connection has failed or the wiring is incorrect. • The connection between remote and receiver only needs to be made once and is not required after changing the batteries in the remote. RECEIVED 09/01/2022 53 ASPEN BUILDING DEPARTMENT Wiring Diagrams The following diagrams show the electrical wiring required for different feature combinations. Wiring Diagram: Screen Fireplace Spark Plug j (G13) II ; II 1 II ' Spark Receiver Wire (G3 (G11) Red Cable(G45) Black Cable imi Green Cable White Cable imini Gas Pipe 5 8-Wire Cable c? a 3 11 (G09) . a X w U E co AC Adapter ['Yellow Switch 10 o z o (G62) Gabble a I •� t ` '.. 11 4 ALAL Wi-Fi box(optional) Gas Valve (G202-XRBG) I � I (G02) I'l e O e Thermocouple Block(G07) RECEIVED 09/01/2022 54 ASPEN BUILDING DEPARTMENT Wiring Diagram: Screen Fireplace with Interior Lighting • Spark Plug (G13)AL -Black Cable ,;, ii III -Green Cable I Spark Wire White Cable (G11) �I �� Red Cable(cas) siamiGas Pipe 111 SW it _ .' Receiver W.: (G301) «. Light F Control P- , N. ®. Box 8- (G890) 5 a) 8-Wire Cable a) Z (G09) Q� v W Yellow O o a o 2 Switch 3 $ (17 Cable E� Lt cc;o_Ns (G10) xi_? JIB L Gas Valve il. T, (G02) • 1 • Wi-Fi box • (G202-XRBG)(optional) 1 5 i'e- F llf I. Light 44IW — Thermocouple Block(G07) Power Cord, 120V (M122) RECEIVED 09/01/2022 55 ASPEN BUILDING DEPARTMENT Wiring Diagram: Double Glass Fireplace Spark Plug(G13) J Spark Wire(G11) -Black Cable • Red Cable Green Cable Relay 5Receiver (G45) White Cable (SASRLSY) f (G301) on Gas Pipe ■11 I i iiti 8-Wire Cable 2) X W (G09) Double Glass 0 cz,Lri 00 AC Adapter Switch Aux Cable Box 0 iL o s (G62) (G205) m a i-z 5?o (G10)e 0 5 Wi-Fi Box aGas Valve (G202-XRGB)(optional) I (G02) �sosasososos i•I " I i Thermocouple $ Block(G07) oG v Fens 1 . Gros ReaY I— Safety Box l High Voltage (SASDGSAFSB) 111 ow Double Glass(DG)Fans Power Cord, 120V(M122) (M D602) RECEIVED 09/01/2022 56 ASPEN BUILDING DEPARTMENT Wiring Diagram: Double Glass Fireplace with Interior Lighting Spark Plug(G13) ii III '1 Spark Wire(Gil) -Black Cable s a'j {I ) d"� Receiver Red Cable Mat $ re (G45) -Green Cable Relay (G301) White Cable (SASRLSY) _I «: il Gas Pipe 1 �' Light a r I '•. Control Q_o w 8-Wire Cable Box a) =ri X 2 (G09) Double Glass (G890) , „ o^ m° a).c Yellow E ►i a o a •Switch Aux Cable Box 2 L cj 3 N a (G205) o �L o v Cable v ~z— (G1o) o U 8 0 ii Wi-Fi Box I `4 -NM 1 ,..' ® �.. (G202-XRGB)(optional) I Gas Valve .• ... ..C. 1 :e .a (G02) 1 1 � 1' Ir Light ' Power Cord, 120V(M122) Thermocouple Block(G07) V-out DG Fans E d G205 Relay ' Safety Box High Voltage (SASDGSAFSB) r Double Glass(DG)Fans Power Cord, 120V(M122) (MD602) 0000 TSSSI RECEIVED 09/01/2022 57 ASPEN BUILDING DEPARTMENT Home Automation Wiring Diagram Use the following wiring diagram to connect fireplace control a hardwired home automation system. Contacts Options/Operation Ignition: Close contacts 0(orange)and 2(brown)simultaneously for 1 second. Fireplace automatically goes to high after ignition. Up Flame: Close contacts 0(orange)and 1 (red)simultaneously.The contact needs to be closed for 12 seconds to turn the motor from end-stop to end-stop. Down Flame: Close contacts 0(orange)and 3(black)simultaneously.The contact needs to be closed for 12 seconds to turn the motor from end-stop to end-stop. Off: Close contacts 0(orange)and 3(black)simultaneously for 1 second. Mode Contact Ignition 0 and 2 Up Flame 0 and 1 Down Flame 0 and 3 SW Tc Off 0 and 2 N� SW TC 3 = black / MA 2 = brown s GR 1 = red 3 Mo 0 = orange J w 1 Z a� , _ o e . 3tteries • 4:1—O3 Cable w/connector G60-ZCE/1000 Wiring Diagram and Operation Sequence Mode of Operation:The external source provides ON and OFF operation only.The Timer/Thermostat handset provides all other functions. NOTICE:The Timer/Thermostat handset in Thermostatic Model controls the room temperature even if the fire is turned on by the external source. If the handset is in Manual Mode,the fire will go to High Fire in the next cycle of external operation. NOTE: This wiring diagram is for hardwired home automation systems only and will not connect the fireplace to a wireless system. Interior Design Media Ortal offers interior media options such as stones,glass,logs,and embers that can provided with the fireplace.This section provides guidelines for safe placement of media. It is crucial that the placement guidelines outlined below are followed as a large portion of flame quality issues are caused by improper media setup. •WARNING: Only media provided by Ortal is permitted for use in the fireplace. •WARNINGS: INSTALLING AND HANDLING MEDIA • DO NOT install the interior design media until fireplace installation is complete,the gas line is connected and tested for leaks,and initial burner operation has been inspected and approved. • Media materials get very hot and will remain hot more than an hour after gas supply is turned off. Handle media only when materials are cool. • If media is not installed according to the installation instructions, flame impingement and improper combustion may occur and result in soot and/or excessive production of carbon monoxide(CO). Carbon monoxide is a toxic, colorless, and odorless gas. WARNING:The fireplace is NOT designed to burn wood.Any attempt to do so could cause irreparable damage to the fireplace and may result in property damage,personal injury and/or loss of life. RECEIVED 09/01/2022 58 ASPEN BUILDING DEPARTMENT Media Placement Guidelines When installing media,adhere to the following general guidelines: • Keep the media back from the pilot hood so at least one burner port is open. Crowding around the pilot hood may hinder lighting and could result in potential damage to the fireplace and surrounding area or personal injury. • • . ;6%, • 1. • '4. 'f * %'., ` /c_ , /1 rA` �, `I ' • • ••': i 4 /100 --- i 4 —! _ - ..• I - • Do not use the hood to support media.This could cause overheating of the thermocouple. • Keep the media away from the edges and the glass. • Do not overfill the media tray. Keep 20%of the tray open to allow for air flow. Glass Media Placement • When placing glass media, put only a single layer,and do not pack down. Once the media is placed,go back and move the glass back slightly to open the ports: • '.. 1: — — ._ . , _ • 1. •,i �_. ' - '- : y. „ .. . . � ' � ,. • • f .%I Stone Media Placement • When placing stone media, use the space left by the round shape to leave the ports open. F °.-0 , is rI. (I/ RECEIVED 09/01/2022 59 ASPEN BUILDING DEPARTMENT Log Media Placement • Place the logs carefully to block as few ports as possible. If a log is placed over a port, block the port with a"coin"to keep the flame from creating soot on the media or to manipulate the look of the flame. 04............__-€. ' :,:, \ T CP • • • .• • • a • at s • • • J• • • ♦ • ]. -- I. �..-,• • ce ■ Block as few ports as possible, and no more than 30%of total ports. Do NOT block ports that are next to one another. • When combining both logs and glass,it is recommended to place the logs(and coins if needed)first,and then to spread the glass according to the instructions given above. ■ illholliVIII4T i RECEIVED 09/01/2022 60 ASPEN BUILDING DEPARTMENT Operation WARNING—Read these instructions carefully before lighting the fireplace. Four operation options are available for use with the fireplace: • 10-Button Remote Control Handset(default option,always included with the fireplace) • Puck Handset(optional accessory) • Wall Switch(optional accessory) • MyFire Application(optional accessory,Wi-Fi capabilities automatically included with the fireplace) IMPORTANT: The 10-Button remote control handset is always included with the fireplace regardless of which operation option is chosen. DO NOT DISCARD.The 10-Button remote must be kept within 26 feet of the fireplace at all times. NOTES: • Wiring of valve and receiver must be completed before starting ignition. Failure to do so could damage the electronics. • If operating the fireplace without an AC adapter, battery replacement is recommended at the beginning of each heating season. • Fireplaces with double glass, power vent, and/or interior lighting features must operate using the AC Adapter and therefore will not operate during a power failure. • Only the Mertik Maxitrol AC Adapter is permitted for use with the fireplace. Use of other adapter brands can render the system inoperable.The handsets, receivers,wall switches are not interchangeable with other electronics. • Batteries must be kept within their recommended temperature limits(32°F to 131°F). 10-Button Remote Control Handset Child-Proof Time Signal Indicator Setting Thermostatic Mode 1 I I i.r i H AM [ --Battery Status III I•I_I PM -Function Countdown Timer O I 14 Not Used- U ® ® O • ■■■■ _Fahrenheit F or Celcius ++ 0 00 OFF « Light Program Mode----÷ QioN O ® nn + l�^0A .----Eco Mode Temperature Function Not Used- © 2019, Maxitrol Company Control Option Radio Frequency Power Supply 918.0 MHz 2 x 1.5V AAA batteries Replace batteries after 2 years or when low battery 10-Button Handset (U.S. &Canada) (quality alkaline indicator appears on handset display recommended) IMPORTANT: For safety/communication purposes, 10-button handset must be located within 26 feet of the receiver. NOTE: Any device that functions using the same radio frequency as the handset will be affected when handset is in use. Operating Instructions Instructions for operating the 10-Button Handset are shown below. For more in-depth instructions, please refer to the"Homeowner's Fireplace Operation Manual"or"Remote Operation Instructions". NOTE: Some options on the remote may not be available for all fireplaces. RECEIVED 09/01/2022 61 ASPEN BUILDING DEPARTMENT IIIIIIIF Turning the Fireplace On 1. Press the U button until you hear continuous beeping,and a blinking series of lines confirms the start sequence has begun; release buttons. 2. Main gas flows once pilot ignition is confirmed. 3.The system automatically goes into Manual Mode after main burner ignition. U ®®0 NOTE: When pilot ignition is confirmed, motor turns automatically to maximum flame height. 0 0 00 ®® NOTE: If the Timer function has been set and the fireplace is manually turned on, the Timer function will need to be reset. Turning the Fireplace Off 1. Press the U button to turn the fireplace off. OFF NOTE:The fireplace may be turned on again after the OFF icon stops flashing. CD CD Flame Height Adjustment 1.To increase flame height, press and hold the A button to desired flame height. 231 2.To decrease flame height, or to set fireplace to pilot flame only, press and hold the O button. ®®®C 0 ++ CD CD 0® o Puck Handset On/Off Flame Flame Down Up Control Option Radio Frequency Power Supply 918.0 MHz 2 x 1.5V AAA batteries Replace batteries after 2 years or Puck Handset (U.S. &Canada) (quality alkaline when low battery indicator recommended) appears on handset display IMPORTANT:For safety/communication purposes,Puck handset must be located within 26 feet of the receiver. NOTE:Any device that functions using the same radio frequency as the handset will be affected when handset is in use. RECEIVED 09/01/2022 62 ASPEN BUILDING DEPARTMENT Operating Instructions Instructions for operating the Puck Handset are shown below. Turning the Fireplace On/Off ON: V ■ Firmly press and hold the •-/ button until two short beeps confirms the start sequence has begun; release button. • Firmly press the U button. Increase/Decrease Flame Height INCREASE: • To increase flame height, press and hold + button. DECREASE: • To decrease flame height, press and hold—button. • Holding the—button long enough sets the fireplace to pilot flame(Standby Mode). J`r1 Designated Flame Settings DESIGNATED LOW FLAME SETTING V • To go to designated low flame setting,double-click—button. NOTE: Flame goes to High Flame before going to Low Flame. + DESIGNATED HIGH FLAME SETTING • To go to designated high flame setting,double-click+button. JAB' RECEIVED 09/01/2022 63 ASPEN BUILDING DEPARTMENT Wall Switch UP Flame Up /) On/Off ON-OFF Flame Down e DOWN Control Option Radio Frequency Power Supply Wall Switch N/A N/A IMPORTANT: For safety/communication purposes,the 10-button handset must be located within 26 feet of the receiver. Operating Instructions Turning the Fireplace On/Off ON: Press and hold the ON-OFF button until two short beeps confirms the start 4 uv sequence has begun; release button. OFF: Press the ON-OFF button. On/Off ON-OFF ADOWN i a Flame Height Adjustment Flame Up 4 uP INCREASE:To increase flame height, press and hold 6 (up flame)button. DECREASE:To decrease flame height, press and hold 11(down flame)button. ON-OFF Holding the (down flame)button long enough sets the fireplace to pilot flame (Standby Mode). Flame Down e DOWN RECEIVED 09/01/2022 64 ASPEN BUILDING DEPARTMENT MyFire App The MyFire app requires the Wi-Fi kit to operate with the fireplace.The Wi-Fi kit does not automatically come with the fireplace and must be ordered. •••• - � �0 0 -.ti r. . •r • r-f ?lo• „kw; rre myfiree 0 . 0 . Download on the ANDROID APP ON App Store 1► Google Play IMPORTANT: For safety/communication purposes,the 10-button handset must be located within 26 feet of the receiver. To download the MyFire app,search"MyFire"at the Apple App Store or Google Play. Operating Instructions For setup and operating instructions of the MyFire app, see the Homeowner's Fireplace Operation Manual,or visit the Ortal website or www.myfireapp.com. MyFire Wi-Fi Box The MyFire Wi-Fi router box provides the Wi-Fi connection that allows the MyFire App to operate the fireplace.This part is included with the optional Wi-Fi kit.Wi-Fi kit does not automatically come with the fireplace and must be ordered. C Ef I -. -2019,Maxltrol Gpmpeny Part Radio Frequency Power Supply Wireless Communication WPA2 authentication MyFire Wi-Fi Box 2.4 GHz Connects to Receiver AES 256-bit encryption security Compatible with IEEE 802.11 b/g/n RECEIVED 09/01/2022 65 ASPEN BUILDING DEPARTMENT Fireplace Maintenance General Maintenance All servicing, maintenance, interior cleaning and handling of the fireplace, parts and glass must be performed by an authorized Ortal dealer service technician only. Servicing • Turn off the gas and electricity BEFORE servicing the fireplace. • It is recommended that a routine inspection is performed at the beginning of each heating season. • When removing glass from multisided fireplaces,only one side of glass can be removed at a time.Glass must be re-installed before removing glass from a different side. Burner and Vent Inspections • Periodic checks should be made of the burner for correct position and condition. Visually check the flame of the burner, making sure that the flames are steady. • The vent system must be inspected before use.Annual inspection must be scheduled to ensure the flow of combustion and ventilation air. Submerged Parts • Do not use the fireplace if any part has been under water, or if you suspect that it may have been under water. The Ortal dealer service technician must inspect and,if necessary,replace any parts of the control system and any gas controls which have been under water. Handling the Glass Inner glass panel is 5mm ceramic glass. Exterior double glass panel is 3/16"tempered glass.Tempered glass can be sourced locally if replacement becomes necessary.Ceramic glass must be provided by Ortal. • When removing glass from multisided fireplaces,only one side of glass can be removed at a time.Glass must be re-installed before removing glass from a different side. • NEVER operate the fireplace without the glass properly securely in place. • The glass must be removed ONLY by an authorized Ortal dealer service technician. • Only an Ortal certified installer is authorized to remove the glass. Glass must be removed using an 8-inch glass-handling suction cup. Lower the glass to rest in a safe place to prevent damage to the glass edges. Cleaning the Fireplace • Only an Ortal dealer service technician can open the fireplace to clean interior surfaces. • ALWAYS turn off the gas valve before cleaning. • Do NOT clean when hot. Make sure fireplace has had time to cool prior to cleaning any surface or component, interior or exterior. • Keep the fireplace clean by brushing and/or vacuuming at least once a year.This can only be performed by an Ortal dealer service technician. • When removing glass from multisided fireplaces,only one side of glass can be removed at a time.Glass must be re-installed before removing glass from a different side. • Clean the glass when it starts to look cloudy. Use a damp cloth for cleaning the fireplace and the door. • Verify correct operation after servicing. Maintenance Frequency and Equipment Checklist • Under normal circumstances,the factory recommendation is to have the fireplace serviced at least once a year. Fireplaces meeting the following conditions should have more frequent service: • Fireplaces installed in commercial/public spaces should be serviced every 3 months. • Fireplaces installed in climates near the ocean or in other settings where corrosion buildup is more likely should be serviced every 6 months. • Thermocouple Maintenance: • The thermocouple should be replaced annually or as needed in all commercial installations, and in any residential fireplace where the fireplace is operated for an average of 10 hours or more per day. • For all other installations,the thermocouple should be replaced every three years or as needed. RECEIVED 09/01/2022 66 ASPEN BUILDING DEPARTMENT © Ortal 2022 Version 3.7, February 2022 SKU: KPMANUALUS3.7 Ortal USA 8421 Canoga Ave Canoga Park, CA 91304 RECEIVED T: (818) 238-7000 I F: (818) 678-0541 info@ortalheat.com I www.ortalheat.com 09/01/2022 ASPEN BUILDING DEPARTMENT