HomeMy WebLinkAboutFile Documents.1034 E Cooper Ave.0125-2022-BRES (5)
Property Address
1034 E. Cooper Ave. Unit 20
Aspen, CO 81611
Element Environmental Project#:
B2 050622 Chateau 20
Client Job Name
Chateau Eau Claire #20
TABLE OF CONTENTS
1.0 - Scope of Work
2.0 - Sampling Requirements
3.0 - Sampling Methodology
4.0 - Laboratory
5.0 - Suspect Materials Sampled
6.0 - Table of Results
7.0 - Description of Sampling Area
8.0 - Conclusion
9.0 - Lab Report
10.0 - Certificates
Asbestos Samples Analyzed: 13
Positive Asbestos Samples: 0
________________________________________
AS
B
E
S
T
O
S
L
E
A
D
HA
Z
M
A
T
RE
S
T
O
R
A
T
I
O
N
ww
w
.
e
l
e
m
e
n
t
co
n
s
u
l
t
s
.c
o
m
Asbestos Sampling Report
Date: 05/09/2022
Date of Inspection: 05/06/2022
Client:
B2 Builders
625 E. Main Suite 102A
Aspen, CO 81611
Attn:
Mark Janian
Building Inspector:
Ellen Johnson
CDPHE #23799
Joshua Johnson
CDPHE #18401
189 County Rd. 135
Glenwood Springs, CO 81601
josh@elementconsults.com
(970) 274-3139
11/09/2022
01/17/2023
jimp
Project #-B2 050622 Chateau 20
2
1.0- This was an inspection for suspect ACM (Asbestos Containing Material) for a remodel.
Element Environmental conducted a visible inspection for visible materials that would
be impacted during the remodel. This inspection was limited to the areas found in the
Description of the Sampling Area 7.0. Although sampling is destructive in nature, this
was a non-invasive inspection. It was of materials that were accessible. If other suspect
materials become visible/apparent during demolition or construction activities, work in
that area should be halted and more sampling/testing must take place, per Colorado
regulations. Any suspect materials that were not tested are to be assumed to contain
asbestos.
2.0- A limited bulk sampling of from all suspect materials was conducted in accordance with
Colorado State Requirements. The minimum number of samples per homogenous areas
are as follows:
2.1- Surfacing Materials- <1,000 sq.ft.- Minimum of 3 samples
1,000 sq.ft.- 5,000sq.ft.- Minimum of 5 samples
>5,000 sq.ft. Minimum of 7 samples
2.2- Miscellaneous materials- Minimum of 2 samples
2.3- Thermal Systems Insulation (TSI)- Minimum of 3 samples
3.0- The purpose of the inspection is to identify materials that are homogenous. A
homogeneous area is defined as one which shares suspect material, texture, color,
location, and/or apparent time of construction. The materials are touched to determine
friability. Friable ACM is material that can be crushed or reduced to powder by hand
pressure. The friable materials are segregated into separate homogenous areas. The size
of the sampling area is determined. Samples are taken according to a random numerical
sequence of the subareas, following guidelines per the EPA Pink Book: Asbestos in
Buildings: Simplified Sampling Scheme for Friable Surfacing Materials.
4.0- Ellen Johnson, a Colorado Department of Public Health & Environment certified building
inspector, certification number: 23799, performed the inspection. The findings were
reviewed by Josh Johnson, a Colorado Department of Public Health & Environment
certified building inspector, certification number: 18401. Samples taken were sent to
CEI Labs in Cary, North Carolina. The samples were analyzed by PLM (Polarized Light
Microscopy) analysis. Per the CDPHE Regulation any sample that is found by a lab to be
trace, or <1% asbestos, is considered to be ACM material. This material would still be a
regulated material by CDPHE. The sample must have an additional “point count”
performed to be considered less than 1% and not be regulated by the CDPHE. The lab’s
documents with analyses and findings are found below.
11/09/2022
01/17/2023
jimp
Project #-B2 050622 Chateau 20
3
5.0- SUSPECT MATERIALS SAMPLES
• Drywall
• Tape
• Joint Compound
• Texture
• Carpet and Pad
• Tile Grout
6.0- TABLE OF RESULTS
HOMOGENOUS
AREA
DESCRIPTION OF AREA ACM CATEGORY NUMBER
OF
SAMPLES
APPROXIMATE
SQ.FT.*
ACM ASSESSMENT CATEGORIES
% AND TYPE OF
ASBESTOS FOUND
(A) Light Roll Texture Throughout
Unit
Surfacing
5 ~3,500 sq.ft. Friable Non ACM No Asbestos Detected
(B) Drywall System Throughout Miscellaneous
2 ~3,500 sq.ft. Friable Non ACM No Asbestos Detected
(C) Carpet Miscellaneous
2 ~300 sq.ft. Non-Friable Non ACM No Asbestos Detected
(D) Pad Miscellaneous
2 ~500 sq.ft. Non-Friable Non ACM No Asbestos Detected
(E) Tile Grout in Kitchen and Baths Miscellaneous
2 ~500 sq.ft. Friable Non ACM No Asbestos Detected
Key:
ACM Assessment Categories:
1- Damaged or significantly damaged Thermal Systems Insulation
(TSI) ACM
2- Damaged friable surfacing ACM
3- Significantly damaged friable Surfacing ACM
4- Damaged or significantly damaged friable Miscellaneous ACM
5- ACM with potential for damage
6- ACM with potential for significant damage
7- Friable ACM with low potential for damage
Other- ACM not classified in the above Assessment Categories
N/A- Not Applicable
* Square footage is estimated and not for bidding purposes
7.0- DESCRIPTION OF SAMPLING AREA
• The Light Roll Texture on walls and ceiling throughout
• The Drywall System throughout
• The Carpet and Pad
• Tile Grout in Bathrooms and Kitchen
11/09/2022
01/17/2023
jimp
Project #-B2 050622 Chateau 20
4
Sampling Locations
N
NTS
8.0- CONCLUSION
No asbestos was detected in any of the samples taken.
Sincerely,
Ellen Johnson
11/09/2022
01/17/2023
jimp
Project #-B2 050622 Chateau 20
5
9.0- LAB REPORT
11/09/2022
01/17/2023
jimp
Project #-B2 050622 Chateau 20
6
11/09/2022
01/17/2023
jimp
Project #-B2 050622 Chateau 20
7
11/09/2022
01/17/2023
jimp
Project #-B2 050622 Chateau 20
8
11/09/2022
01/17/2023
jimp
Project #-B2 050622 Chateau 20
9
11/09/2022
01/17/2023
jimp
Project #-B2 050622 Chateau 20
10
11/09/2022
01/17/2023
jimp
Project #-B2 050622 Chateau 20
11
11/09/2022
01/17/2023
jimp
Project #-B2 050622 Chateau 20
12