Loading...
HomeMy WebLinkAboutFile Documents.520 E Cooper Ave.0057-2022-BCOM (7)Job Name Location Purchaser Engineer Submitted to Reference Approval Construction Unit Designation Schedule # SUBMITTAL www.SamsungHVAC.com 888-699-6067 Page 1of 2 AM018TNVDCH/AA Samsung DVM S Series, Wind-Free™ Wall-Mounted Unit Specifications 1 Nominal cooling capacities are based on: Indoor temperature: 80°F DB, 67°F WB. Outdoor temperature: 95°F DB, 75°F WB Nominal heating capacities are based on: Indoor temperature: 70°F DB, 60°F WB. Outdoor temperature: 47°F DB, 43°F WB *The Wind-Free™ unit delivers an air current that is under 0.15 m/s while in Wind-Free™ mode. Air velocity that is below 0.15 m/s is considered “still air” as defined by ASHRAE (American Society of Heating, Refrigerating, and Air-Conditioning Engineers). Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice. •Compatible with Samsung DVM S, DVM S Water, and DVM S Eco systems (AM**********AA). • Electro-static, washable, pleated filters as standard (included with unit) •7-segment digital display on front of unit to display temperature and unit status • High-voltage terminal block temperature sensor to disable unit in the event overheating of power connection. Construction HIPS chassis certified to UL94 V0 with galvanized steel mounting bracket Heat Exchanger The heat exchanger shall be mechanically bonded fin to copper tube Indoor Fan Indoor fan is a single, antibacterial, crossflow type Three fan speed settings and auto setting Controls The unit shall be operated via a wireless or wired remote control with DDC type signal The unit shall integrate with the Samsung NASA Controls Network Solution Controls shall integrate with a BMS system © 2020 Samsung HVAC SHA-DVMS-05052020 •Wind-Free™ function will close the supply air outlet louver while in cooling mode to gently disperse cool air into the space without blowing directly onto occupants. The Wind-Free™ feature is optional and can be enabled using central or local control options (MWR-SH11UN, MWR-WE13UN, MWR-WG00*N, and AR-EH0*U only). Control wiring shall be 2 X 16 AWG shielded wire Automatic (motorized) vertical swing (up/down) and horizontal swing (left/right) louvers Cooling (Btu/h)18,000 Heating (Btu/h)20,000 1 / 208-230 / 60 0.35 Crossflow Type BLDC (1) Output (W)27 Airflow CFM (UL)L/M/H 424 / 487 / 555 R410A Electronic Expansion Valve Liquid (flare) Inches 1/4 Suction (flare) Inches 1/2 Drain Inches ID 11/16 Hose W X H X D Inches 41 1/2 X 11 3/4 X 8 7/16 Weight lbs.26.5 Sound Level L / M / H dB(A)34 / 37 / 40 MIM-B14 Aspen Mini Orange ASP-MO-UNIV 110-250 Blue Diamond BD-BLUE230 MRW-TA ETL (UL 1995)Safety Certifications Power MCA MOP Piping Connections Unit Dimensions Accessories External Contact Control Condensate Pump External Temperature Sensor Fan Type Motor Refrigerant Type Control Method Performance Nominal Capacity1 Voltage (ø/V/Hz) Nominal Running Current (A) 0.44 15 By Greg Hinkle at 10:19 am, May 10, 2022 12/12/2022 Through penetrations of existing fire rated exterior walls to be protected with a listed firestop system unless the penetrating item meets the exceptions to IBC 714.3.1. www.SamsungHVAC.com SUBMITTAL 5" Minimum 5" Minimum 3 15/16" Minimum Minimum clearances from walls and ceiling AM018TNVDCH/AA Samsung DVM S Series, Wind-Free™ Wall-Mounted Unit Page 2of 2 Unit: inches 41 1/2 11 3 / 4 21 1/820 3/8 2 7 / 1 6 2 9/1 6 2 9/16 24 7/8 3 5/16 1 1 / 8 2 1/22 1/26 15/16 1 1 / 8 41 1/2 8 7/16 11 3 / 4 2 9 / 1 6 2 5 / 1 6 2 7/16 12/12/2022