Loading...
HomeMy WebLinkAboutFile Documents.555 E Durant Ave.0055-2023-BCHO (8)SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK SEE NOTES #1 PLANS It should be known that this review shall not relieve the applicant of their responsibility to comply with the requirements of the City of Aspen Municipal Code. Pursuant to Sec.26.104.050, any permit or approval issued in error or otherwise not in conformity with the requirements of this Title, shall be void. Similarly, any permit or approval issued in reliance upon or as a result of, a materially false statement or representation made in the process of obtaining the permit or development approval shall, likewise, be void. Any person having received a void or voidable permit or approval shall not be relieved from having to comply with all applicable terms and conditions of this Title and the City shall not be estopped from fully enforcing same. READ THIS OR FAIL YOUR INSPECTION! Furred & Dropped Ceilings, Soffits, and Walls 20015 IBC 803.13 This applies to the attachment of finishes or furring to any assemblies that are required to be either fire-rated or non-combustible and is separate from the fire-rated assembly requirement. Walls, Ceilings & Soffits: If furred 1 ¾ inches or less, do one of the following: 4.Fill spaces with Class A material. 5.Fill spaces with inorganic or non-combustible material. 6.Fire block 8 feet in all directions. Walls: If set out (furred) greater than 1 ¾ inches, do one of the following: 4.Use a Class A finish material (such as drywall). 5.Use non-combustible framing. 6.Protect both sides with fire sprinklers. Ceilings & Soffits: If dropped (furred) greater than 1 ¾ inches: Framing members, hangers, and other assembly members must be non-combustible. You may not use wood. In Type III and V construction only, you may use fire retardant treated wood or non-combustible framing. 2015 IBC 601 Fire Resistive Requirements for Type of Construction: ____ Primary Structural Frame: ____hr (columns, beams, girders, etc) Exterior Bearing Walls: ____hr Interior Bearing Walls: ____hr Floors/Ceilings: ____hr Roof : ____hr Unless noted otherwise for occupancy separation or fire separation distance. IIIA 1 2 1 1 1 75% of lamps in permanently installed light fixtures shall be high efficacy - IECC R404.1 Any recessed light fixtures in contact with insulation must be IC rated. Recessed luminaires installed in building thermal envelope shall be sealed and IC-rated – IECC sec R402.4.5 FIRE RATED HATS REQUIRED Where floor/ceiling or roof/ceiling assemblies are required to have a fire-resistive rating, recessed fixtures shall be installed such that the required fire resistance will not be reduced (IBC 714.4.2) CEILING RADIATION DAMPERS REQUIRED Ducts and air transfer openings penetrating the ceiling of a fire rated ceiling assembly must be protected with a listed ceiling radiation damper. This includes bathroom exhaust fans. (IBC 717.6.2) FIRE SPRINKLERS REQUIRED 555 E DURANT: NORTH OF NELL 3C CHANGE ORDER 1 NARRATIVE ARCHITECTURAL: Updates include modification to the interior partition layout, modification to the kitchen and bath layout, new laundry location, revised lighting locations, revised fireplace manufacturer. Please see sheets A-120 and A-121 for changes. 06/12/2023 08/02/2023 justinh 06/12/2023 APPLICATION ACCEPTED DATE: 2023-06-12 PERMIT NUMBER: 0055-2023-BCHO COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT COVERSHEET PROPERTY INFORMATION ADDRESS: 555 E DURANT AVE 3C UNIT: PARCEL ID: 273718249033 LEGAL DESCRIPTION: NORTH OF NELL OWNER: CHATEAU HYMAN LLC PERMIT CONTRACTOR: KAEGEBEIN FINE HOMEBUILDING LLC DESCRIPTION OF WORK ALTERATION TO PROPOSED INTERIOR PARTITIONS, MOVE WASHER AND DRYER, CHANGE FIREPLACE, REVISED KITCHEN LAYOUT. USE OF BUILDING Mixed-Use FIRE SPRINKLER REQUIRED? Yes CLASS OF WORK Residential FIRE SPRINKLER TYPE NFPA 13 BUILDING TYPE (IRC) REQUIRED SPECIAL INSPECTIONS CONSTRUCTION TYPE IIIA ENERGY CODE COMPLIANCE Prescriptive Table OCCUPANCY GROUP (IBC) WORK CHANGES BUILDING FOOTPRINT? No CODE EDITIONS 2015 IBC TOTAL SPA SQ.FT. OTHER CODE EDITIONS TOTAL SNOWMELT SQ.FT. HISTORIC PROPERTY? No TOTAL POOL SQ.FT. FIRE SPRINKLER EXISTING? Yes 1 MASTER PERMIT 0092-2022-BRES