HomeMy WebLinkAboutFile Documents.555 E Durant Ave.0092-2022-BRES (18)SMOKE ALARMS AND
CARBON MONOXIDE
DETECTORS REQUIRED
THROUGHOUT DWELLING
UNIT PER CITY OF ASPEN
MUNICIPAL CODE 8.15
These plans must be kept at the
building site or inspection
delays may occur. Construction
shall conform to these plans. All
changes shall be approved by
the building official.
Field Plan Set Must Be Printed In Color
SEPARATE PERMITS ARE
REQUIRED FOR ELECTRICAL,
PLUMBING, MECHANICAL, OR
FIRE SPRINKLER WORK
It should be known that this review shall
not relieve the applicant of their
responsibility to comply with the
requirements of the City of Aspen
Municipal Code. Pursuant to
Sec.26.104.050, any permit or approval
issued in error or otherwise not in
conformity with the requirements of this
Title, shall be void. Similarly, any permit
or approval issued in reliance upon or
as a result of, a materially false
statement or representation made in
the process of obtaining the permit or
development approval shall, likewise,
be void. Any person having received a
void or voidable permit or approval
shall not be relieved from having to
comply with all applicable terms and
conditions of this Title and the City shall
not be estopped from fully enforcing
same.
08/11/2022
kylas
07/28/2022
READ THIS OR FAIL YOUR INSPECTION!
Furred & Dropped Ceilings, Soffits, and Walls
20015 IBC 803.13
This applies to the attachment of finishes or furring to any
assemblies that are required to be either fire-rated or
non-combustible and is separate from the fire-rated
assembly requirement.
Walls, Ceilings & Soffits: If furred 1 ¾ inches or
less, do one of the following:
4.Fill spaces with Class A material.
5.Fill spaces with inorganic or non-combustible material.
6.Fire block 8 feet in all directions.
Walls: If set out (furred) greater than 1 ¾ inches,
do one of the following:
4.Use a Class A finish material (such as drywall).
5.Use non-combustible framing.
6.Protect both sides with fire sprinklers.
Ceilings & Soffits: If dropped (furred) greater
than 1 ¾ inches:
Framing members, hangers, and other assembly
members must be non-combustible. You may not
use wood.
In Type III and V construction only, you may use fire
retardant treated wood or non-combustible framing.
2015 IBC 601 Fire Resistive Requirements for
Type of Construction: ____
Primary Structural Frame: ____hr
(columns, beams, girders, etc)
Exterior Bearing Walls: ____hr
Interior Bearing Walls: ____hr
Floors/Ceilings: ____hr
Roof : ____hr
Unless noted otherwise for occupancy separation or fire
separation distance.
IIIA
1
2
1
1
1
75% of lamps in permanently
installed light fixtures shall be
high efficacy - IECC R404.1
Any recessed light fixtures
in contact with insulation
must be IC rated.
Recessed luminaires installed
in building thermal envelope
shall be sealed and IC-rated
– IECC sec R402.4.5
FIRE RATED HATS REQUIRED
Where floor/ceiling or roof/ceiling
assemblies are required to have a
fire-resistive rating, recessed fixtures shall
be installed such that the required fire
resistance will not be reduced (IBC 714.4.2)
CEILING RADIATION DAMPERS REQUIRED
Ducts and air transfer openings penetrating the ceiling of
a fire rated ceiling assembly must be protected with a
listed ceiling radiation damper. This includes bathroom
exhaust fans. (IBC 717.6.2)
FIRE
SPRINKLERS
REQUIRED
12/05/2022
justinh
0092-2022-BRES
Chateau Hyman LLC
555 E Durang 3C
273718249033
APPLICATION ACCEPTED DATE: 2022-08-08 PERMIT NUMBER: 0092-2022-BRES
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT COVERSHEET
PROPERTY INFORMATION
ADDRESS: 555 E DURANT AVE 3C UNIT:
PARCEL ID: 273718249033 LEGAL DESCRIPTION: NORTH OF NELL
OWNER: CHATEAU HYMAN LLC
PERMIT CONTRACTOR: KAEGEBEIN FINE HOMEBUILDING LLC
DESCRIPTION OF WORK INTERIOR REMODEL OF EXISTING CONDO UNIT. REPLACEMENT OF EXISTING SLIDERS.
USE OF BUILDING Mixed -Use FIRE SPRINKLER REQUIRED? Yes
CLASS OF WORK Residential FIRE SPRINKLER TYPE NFPA 13
BUILDING TYPE (IRC) REQUIRED SPECIAL
INSPECTIONS
CONSTRUCTION TYPE IIIA ENERGY CODE COMPLIANCE Prescriptive Table
OCCUPANCY GROUP (IBC) R -2 WORK CHANGES BUILDING
FOOTPRINT? No
CODE EDITIONS 2015 IBC TOTAL SPA SQ.FT.
OTHER CODE EDITIONS TOTAL SNOWMELT SQ.FT.
HISTORIC PROPERTY? No TOTAL POOL SQ.FT.
FIRE SPRINKLER EXISTING? Yes
CITY OF ASPEN|2022 427 RIO GRANDE PL | ASPEN, CO
81611
2x10 or Greater Joist Floor/Ceiling 1 hour fire, STC 51 assembly from the Gypsum Manual (GA-600 Fire
Resistance Design Manual):
(No IIC given. Must use an underlayment product or carpet to achieve IIC 50)