HomeMy WebLinkAboutFile Documents.205 S Mill St.0049-2023-BCOM (6)SMOKE ALARMS AND
CARBON MONOXIDE
DETECTORS REQUIRED
THROUGHOUT DWELLING
UNIT PER CITY OF ASPEN
MUNICIPAL CODE 8.15
These plans must be kept at the
building site or inspection
delays may occur. Construction
shall conform to these plans. All
changes shall be approved by
the building official.
Field Plan Set Must Be Printed In Color
SEPARATE PERMITS ARE
REQUIRED FOR ELECTRICAL,
PLUMBING, MECHANICAL, OR
FIRE SPRINKLER WORK
It should be known that this review shall
not relieve the applicant of their
responsibility to comply with the
requirements of the City of Aspen
Municipal Code. Pursuant to
Sec.26.104.050, any permit or approval
issued in error or otherwise not in
conformity with the requirements of this
Title, shall be void. Similarly, any permit
or approval issued in reliance upon or
as a result of, a materially false
statement or representation made in
the process of obtaining the permit or
development approval shall, likewise,
be void. Any person having received a
void or voidable permit or approval
shall not be relieved from having to
comply with all applicable terms and
conditions of this Title and the City shall
not be estopped from fully enforcing
same.
SPECIAL INSPECTION REQUIRED:
-Structural steel welding: Field & Shop
-High strength bolting
-Epoxy anchors
-Intumescent paint
-Spray applied fire resistive materials
-Permanent micropiles
-Penetration Firestopping
Special inspection is required per 2021 IBC
section 1704. Inspector to verify that copy of
agreement for inspection program to be on
the job site prior to performing any
inspections. A copy of all Special Inspector
field reports to be on the job site for
inspectors' review if requested. Failure to
comply may result in denial of inspection.
09/28/2023
justinh
2021 IBC 601 Fire Resistive Requirements for
Type of Construction: ____
Primary Structural Frame: ____hr
(columns, beams, girders, etc)
Exterior Bearing Walls: ____hr
Interior Bearing Walls: ____hr
Floors/Ceilings: ____hr
Roof : ____hr
Unless noted otherwise for occupancy separation or fire
separation distance.
VA
1
1
1
1
1
Anchorage points complying with
ANSI/ASSE Z359.1 required for
work within 10' of roof edge
where guards complying with
IBC 1015.6 are not provided.
APPLICATION ACCEPTED DATE: 2023-09-21 PERMIT NUMBER: 0049-2023-BCOM
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT COVERSHEET
PROPERTY INFORMATION
ADDRESS: 205 S MILL ST 3 UNIT:
PARCEL ID: 273707338004 LEGAL DESCRIPTION: CITY AND TOWNSITE OF ASPEN
OWNER: MILL STREET PLAZA ASSOC LLC
PERMIT CONTRACTOR:
DESCRIPTION OF WORK REMOVE EXIST ONMI ANTENNAS FROM EXIST BALLAST ANTENNA FRAMES & ANTENNA MOUNTS. INSTALL (1)
NEW ANTENNAS TO RELOCATED BALLAST FRAME. INSTALL (2) REMOTE RADIO HEADS, (1) RELOCATED RADIO
HEAD AND (1) NEW OVER VOLTAGE PROTECTOR TO THE RELOCATED BALLAST FROM UNDER THE NEW
ANTENNAS. RELOCATE EXISTING EQUIPMENT TO (2) NEW EQUIPMENT CABINETS ON NEW ROOFTOP STEEL
PLATFORM. NEW ROOFTOP ACCESS LADDER MOUNTED TO S OF THE BUILDING IN THE ALLEYWAY
USE OF BUILDING Commercial FIRE SPRINKLER REQUIRED? No
CLASS OF WORK Commercial FIRE SPRINKLER TYPE
BUILDING TYPE (IRC) REQUIRED SPECIAL
INSPECTIONS
High-Strength Bolting;Structural
Steel Welding
CONSTRUCTION TYPE VA ENERGY CODE COMPLIANCE
OCCUPANCY GROUP (IBC) B WORK CHANGES BUILDING
FOOTPRINT? No
CODE EDITIONS Other TOTAL SPA SQ.FT.
OTHER CODE EDITIONS 2021 TOTAL SNOWMELT SQ.FT.
HISTORIC PROPERTY? No TOTAL POOL SQ.FT.
FIRE SPRINKLER EXISTING?
RE
V
I
E
W
E
D
F
O
R
CO
M
P
L
I
A
N
C
E
10
/
1
7
/
2
0
2
3
s
t
u
a
r
t
h
BY
H
P
C
Mike Otegui mikeo@oteguieng.com02/07/2024
Ashley Christensen -
owner agent Ashley Christensen 02/07/2024 achristensen@csainet.com
Justin Hahn 2/8/24 justin.hahn@aspen.govJustin Hahn
Digitally signed by Justin Hahn
DN: C=US,
E=justin.hahn@aspen.gov,
O=City of Aspen, OU=Building
Department, CN=Justin Hahn
Reason: I have reviewed this
document