Loading...
HomeMy WebLinkAboutFile Documents.520 E Cooper Ave.0057-2022-BCOM (8)SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK It should be known that this review shall not relieve the applicant of their responsibility to comply with the requirements of the City of Aspen Municipal Code. Pursuant to Sec.26.104.050, any permit or approval issued in error or otherwise not in conformity with the requirements of this Title, shall be void. Similarly, any permit or approval issued in reliance upon or as a result of, a materially false statement or representation made in the process of obtaining the permit or development approval shall, likewise, be void. Any person having received a void or voidable permit or approval shall not be relieved from having to comply with all applicable terms and conditions of this Title and the City shall not be estopped from fully enforcing same. Zoning inspection note: no exterior changes in scope. This includes ventilation, exterior mechanical equipment, etc. COMcheck Software Version COMcheckWeb Interior Lighting Compliance Certificate Project Title: 2015 IECC Project Type:Alteration Construction Site: 520 E COOPER C-8, C-5 ASPEN, Colorado 81611 Owner/Agent:Designer/Contractor: Project Information Energy Code: 520 E Cooper: C-8, C-5 Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts 1-OFFICE 27 (Common Space Types:Office - Enclosed)155 1.11 172 2-OFFICE 26 (Common Space Types:Office - Enclosed)122 1.11 135 3-BUSINESS USE (Common Space Types:Storage >=50 - <=1000 sq.ft.)114 0.63 72 379Total Allowed Watts = Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixture OFFICE 27 (Common Space Types: Office - Enclosed, 155 sq.ft.) LED: LED Panel 19W:1 4 19 76 OFFICE 26 (Common Space Types: Office - Enclosed, 122 sq.ft.) LED: LED Panel 19W:1 4 19 76 BUSINESS USE (Common Space Types: Storage >=50 - <=1000 sq.ft., 114 sq.ft.) LED: LED Panel 19W:1 4 19 76 228Total Proposed Watts = Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Interior Lighting PASSES Project Title: Data filename: 520 E Cooper: C-8, C-5 11/30/22Report date: 41 ofPage 2022-11-30HANNAH HUNT MOELLER Digitally signed by HANNAH HUNT MOELLER DN: C=US, E=HANNAHHUNT@EIGELBERGER.COM, OU=EIGELBERGER ARCHITECTURE AND DESIGN, CN=HANNAH HUNT MOELLER Date: 2022.11.30 15:03:44-07'00' 12/12/2022 Job Name Location Purchaser Engineer Submitted to Reference Approval Construction Unit Designation Schedule # SUBMITTAL www.SamsungHVAC.com 888-699-6067 Page 1of 2 AM018TNVDCH/AA Samsung DVM S Series, Wind-Free™ Wall-Mounted Unit Specifications 1 Nominal cooling capacities are based on: Indoor temperature: 80°F DB, 67°F WB. Outdoor temperature: 95°F DB, 75°F WB Nominal heating capacities are based on: Indoor temperature: 70°F DB, 60°F WB. Outdoor temperature: 47°F DB, 43°F WB *The Wind-Free™ unit delivers an air current that is under 0.15 m/s while in Wind-Free™ mode. Air velocity that is below 0.15 m/s is considered “still air” as defined by ASHRAE (American Society of Heating, Refrigerating, and Air-Conditioning Engineers). Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice. •Compatible with Samsung DVM S, DVM S Water, and DVM S Eco systems (AM**********AA). • Electro-static, washable, pleated filters as standard (included with unit) •7-segment digital display on front of unit to display temperature and unit status • High-voltage terminal block temperature sensor to disable unit in the event overheating of power connection. Construction HIPS chassis certified to UL94 V0 with galvanized steel mounting bracket Heat Exchanger The heat exchanger shall be mechanically bonded fin to copper tube Indoor Fan Indoor fan is a single, antibacterial, crossflow type Three fan speed settings and auto setting Controls The unit shall be operated via a wireless or wired remote control with DDC type signal The unit shall integrate with the Samsung NASA Controls Network Solution Controls shall integrate with a BMS system © 2020 Samsung HVAC SHA-DVMS-05052020 •Wind-Free™ function will close the supply air outlet louver while in cooling mode to gently disperse cool air into the space without blowing directly onto occupants. The Wind-Free™ feature is optional and can be enabled using central or local control options (MWR-SH11UN, MWR-WE13UN, MWR-WG00*N, and AR-EH0*U only). Control wiring shall be 2 X 16 AWG shielded wire Automatic (motorized) vertical swing (up/down) and horizontal swing (left/right) louvers Cooling (Btu/h)18,000 Heating (Btu/h)20,000 1 / 208-230 / 60 0.35 Crossflow Type BLDC (1) Output (W)27 Airflow CFM (UL)L/M/H 424 / 487 / 555 R410A Electronic Expansion Valve Liquid (flare) Inches 1/4 Suction (flare) Inches 1/2 Drain Inches ID 11/16 Hose W X H X D Inches 41 1/2 X 11 3/4 X 8 7/16 Weight lbs.26.5 Sound Level L / M / H dB(A)34 / 37 / 40 MIM-B14 Aspen Mini Orange ASP-MO-UNIV 110-250 Blue Diamond BD-BLUE230 MRW-TA ETL (UL 1995)Safety Certifications Power MCA MOP Piping Connections Unit Dimensions Accessories External Contact Control Condensate Pump External Temperature Sensor Fan Type Motor Refrigerant Type Control Method Performance Nominal Capacity1 Voltage (ø/V/Hz) Nominal Running Current (A) 0.44 15 520 East Cooper 4 By Greg Hinkle at 10:19 am, May 10, 2022 12/12/2022 Through penetrations of existing fire rated exterior walls to be protected with a listed firestop system unless the penetrating item meets the exceptions to IBC 714.3.1. 01/23/2023 justinh COMcheck Software Version COMcheckWeb Mechanical Compliance Certificate Project Title: 2015 IECC Project Type:Alteration Location:Aspen, Colorado Climate Zone:7 Construction Site: 520 Cooper Ave Aspen, Colorado 81601 Owner/Agent: Bill Guth WNG Group 520 Cooper Ave Aspen, Colorado 81601 Designer/Contractor: Project Information Energy Code: Mechanical Systems List Quantity System Type & Description Heating: 1 each - Other, Electric, Capacity = 34 kBtu/h No minimum efficiency requirement applies Fan System: FAN SYSTEM 1 | Conference -- Compliance (Motor nameplate HP and fan efficiency method) : Passes Fans: FAN 1 Supply, Constant Volume, 280 CFM, 0.2 motor nameplate hp, 0.8 fan efficiency grade, 0.8 total fan efficiency, 0.8 design fan efficiency , fan exception: Single fan <= 5HP 1 HVAC System (Single Zone): Heating: 1 each - Other, Electric, Capacity = 13 kBtu/h No minimum efficiency requirement applies Fan System: FAN SYSTEM 2 | Offices -- Compliance (Motor nameplate HP and fan efficiency method) : Passes Fans: FAN 3 Exhaust, Constant Volume, 130 CFM, 0.1 motor nameplate hp, 0.8 fan efficiency grade, 0.8 total fan efficiency, 0.8 design fan efficiency , fan exception: Single fan <= 5HP FAN 2 Supply, Constant Volume, 130 CFM, 0.1 motor nameplate hp, 0.8 fan efficiency grade, 0.8 total fan efficiency, 0.8 design fan efficiency , fan exception: Single fan <= 5HP 1 HVAC System (Single Zone): Mechanical Compliance Statement Compliance Statement: The proposed mechanical alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2015 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Project Title: Data filename: 11/30/22Report date: 114 ofPage Mike Suhrbier CEM 11/30/2022 12/12/2022 0057-2022-BCOM ASPEN OFFICE PARTNERSHIP LLC 520 E COOPER AVE C8 273718224024 APPLICATION ACCEPTED DATE: 2022-12-13 PERMIT NUMBER: 0057-2022-BCOM COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT COVERSHEET PROPERTY INFORMATION ADDRESS: 520 E COOPER AVE C8 UNIT: PARCEL ID: 273718224024 LEGAL DESCRIPTION: ASPENHOF OWNER: ASPEN OFFICE PARTNERSHIP LLC PERMIT CONTRACTOR: SH BUILDING GROUP LLC DESCRIPTION OF WORK EPIC PERMIT - Interior Only. Remove non-structural wall partitions and add new partitions to reconfigure existing business space. New interior doors and new carpet and wall base. 683 square feet of area is being remodeled. USE OF BUILDING Commercial FIRE SPRINKLER REQUIRED? Yes CLASS OF WORK Commercial FIRE SPRINKLER TYPE NFPA 13 BUILDING TYPE (IRC) REQUIRED SPECIAL INSPECTIONS CONSTRUCTION TYPE IIIA ENERGY CODE COMPLIANCE OCCUPANCY GROUP (IBC) WORK CHANGES BUILDING FOOTPRINT? No CODE EDITIONS 2015 IBC TOTAL SPA SQ.FT. OTHER CODE EDITIONS TOTAL SNOWMELT SQ.FT. HISTORIC PROPERTY? No TOTAL POOL SQ.FT. FIRE SPRINKLER EXISTING? Yes 2015 IBC 601 Fire Resistive Requirements for Type of Construction: ____ Primary Structural Frame: ____hr (columns, beams, girders, etc) Exterior Bearing Walls: ____hr Interior Bearing Walls: ____hr Floors/Ceilings: ____hr Roof : ____hr Unless noted otherwise for occupancy separation or fire separation distance. IIIA 1 2 1 1 1 FIRE RATED HATS REQUIRED Where floor/ceiling or roof/ceiling assemblies are required to have a fire-resistive rating, recessed fixtures shall be installed such that the required fire resistance will not be reduced (IBC 714.4.2) CEILING RADIATION DAMPERS REQUIRED Ducts and air transfer openings penetrating the ceiling of a fire rated ceiling assembly must be protected with a listed ceiling radiation damper. This includes bathroom exhaust fans. (IBC 717.6.2) READ THIS OR FAIL YOUR INSPECTION! Furred & Dropped Ceilings, Soffits, and Walls 20015 IBC 803.13 This applies to the attachment of finishes or furring to any assemblies that are required to be either fire-rated or non-combustible and is separate from the fire-rated assembly requirement. Walls, Ceilings & Soffits: If furred 1 ¾ inches or less, do one of the following: 4.Fill spaces with Class A material. 5.Fill spaces with inorganic or non-combustible material. 6.Fire block 8 feet in all directions. Walls: If set out (furred) greater than 1 ¾ inches, do one of the following: 4.Use a Class A finish material (such as drywall). 5.Use non-combustible framing. 6.Protect both sides with fire sprinklers. Ceilings & Soffits: If dropped (furred) greater than 1 ¾ inches: Framing members, hangers, and other assembly members must be non-combustible. You may not use wood. In Type III and V construction only, you may use fire retardant treated wood or non-combustible framing.FIRE SPRINKLERS REQUIRED