Loading...
HomeMy WebLinkAboutFile Documents.855 Chatfield Rd.0072-2020-BRES (10)REScheck Software Version 4.7.1 Compliance Certificate Project Energy Code:2015 IECC Location:Aspen, Colorado Construction Type:Single-family Project Type:New Construction Conditioned Floor Area:6,980 ft2 Glazing Area 53% Climate Zone:7 (9922 HDD) Permit Date: Construction Site: 855 Chatfield Rd Aspen, CO 81611 Owner/Agent: S2 Architects 215 S. Monarch Suite G-102 Aspen, CO 81611 Designer/Contractor: Dan Findley AEC 40801 US-6 #214 Avon, CO 81620 Permit Number: Compliance: Passes using UA trade-off 2.3% Better Than Code Maximum UA:1586 Your UA:1549 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Compliance: Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA East wall: Wood Frame, 16" o.c.1,608 38.0 6.0 0.032 29 Window 1: Metal Frame:Double Pane with Low-E 591 0.320 189 Door 1: Glass 106 0.320 34 North wall: Wood Frame, 16" o.c.1,347 38.0 6.0 0.032 30 Window 2: Metal Frame:Double Pane with Low-E 405 0.320 130 South Wall: Wood Frame, 16" o.c.1,192 38.0 6.0 0.032 19 Window 3: Metal Frame with Thermal Break:Double Pane with Low-E 611 0.320 196 West Wall: Wood Frame, 16" o.c.2,097 38.0 6.0 0.032 22 Window 4: Metal Frame with Thermal Break:Double Pane with Low-E 353 0.320 113 Door 2: Glass 1,058 0.320 339 Flat roof: Flat Ceiling or Scissor Truss 3,703 19.0 30.0 0.020 74 Basement Wall 1: Solid Concrete or Masonry Wall height: 9.0' Depth below grade: 9.0' Insulation depth: 9.0' 2,136 0.0 15.0 0.041 80 Window 5: Metal Frame:Double Pane with Low-E 176 0.320 56 30 0.0 0.0 0.625 19 Project Title: Data filename: P:\Current Projects\19102.00 - 855 Chatfield Road\Calculations\19102-855 Chatfield Road.rck Page 1 of 2 02/19/21Report date: 03/08/2021 03/08/2021 denism Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA Basement Wall 5 at Den Door: Solid Concrete or Masonry Wall height: 1.0' Depth below grade: 0.0' Insulation depth: 0.0' 17 0.0 0.0 0.625 11 Basement Wall 5 at entry: Solid Concrete or Masonry Wall height: 0.3' Depth below grade: 0.0' Insulation depth: 0.0' 12 0.0 0.0 0.625 8 Floor 1: Slab-On-Grade:Heated Insulation depth: 4.0' 292 10.0 0.684 200 Name - Title Signature Date Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.7.1 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Project Title: Data filename: P:\Current Projects\19102.00 - 855 Chatfield Road\Calculations\19102-855 Chatfield Road.rck Page 2 of 2 02/19/21Report date: Dan Findley - Mechanical Engineer 02/19/2021 03/08/2021 03/08/2021 denism