HomeMy WebLinkAboutFile Documents.855 Chatfield Rd.0072-2020-BRES (10)REScheck Software Version 4.7.1
Compliance Certificate
Project
Energy Code:2015 IECC
Location:Aspen, Colorado
Construction Type:Single-family
Project Type:New Construction
Conditioned Floor Area:6,980 ft2
Glazing Area 53%
Climate Zone:7 (9922 HDD)
Permit Date:
Construction Site:
855 Chatfield Rd
Aspen, CO 81611
Owner/Agent:
S2 Architects
215 S. Monarch Suite G-102
Aspen, CO 81611
Designer/Contractor:
Dan Findley
AEC
40801 US-6 #214
Avon, CO 81620
Permit Number:
Compliance: Passes using UA trade-off
2.3% Better Than Code Maximum UA:1586 Your UA:1549
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Compliance:
Envelope Assemblies
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value U-Factor UA
East wall: Wood Frame, 16" o.c.1,608 38.0 6.0 0.032 29
Window 1: Metal Frame:Double Pane with Low-E 591 0.320 189
Door 1: Glass 106 0.320 34
North wall: Wood Frame, 16" o.c.1,347 38.0 6.0 0.032 30
Window 2: Metal Frame:Double Pane with Low-E 405 0.320 130
South Wall: Wood Frame, 16" o.c.1,192 38.0 6.0 0.032 19
Window 3: Metal Frame with Thermal Break:Double Pane with Low-E 611 0.320 196
West Wall: Wood Frame, 16" o.c.2,097 38.0 6.0 0.032 22
Window 4: Metal Frame with Thermal Break:Double Pane with Low-E 353 0.320 113
Door 2: Glass 1,058 0.320 339
Flat roof: Flat Ceiling or Scissor Truss 3,703 19.0 30.0 0.020 74
Basement Wall 1: Solid Concrete or Masonry
Wall height: 9.0'
Depth below grade: 9.0'
Insulation depth: 9.0'
2,136 0.0 15.0 0.041 80
Window 5: Metal Frame:Double Pane with Low-E 176 0.320 56
30 0.0 0.0 0.625 19
Project Title:
Data filename: P:\Current Projects\19102.00 - 855 Chatfield Road\Calculations\19102-855 Chatfield
Road.rck
Page 1 of 2
02/19/21Report date:
03/08/2021
03/08/2021
denism
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value U-Factor UA
Basement Wall 5 at Den Door: Solid Concrete or Masonry
Wall height: 1.0'
Depth below grade: 0.0'
Insulation depth: 0.0'
17 0.0 0.0 0.625 11
Basement Wall 5 at entry: Solid Concrete or Masonry
Wall height: 0.3'
Depth below grade: 0.0'
Insulation depth: 0.0'
12 0.0 0.0 0.625 8
Floor 1: Slab-On-Grade:Heated
Insulation depth: 4.0'
292 10.0 0.684 200
Name - Title Signature Date
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.7.1 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Project Title:
Data filename: P:\Current Projects\19102.00 - 855 Chatfield Road\Calculations\19102-855 Chatfield
Road.rck
Page 2 of 2
02/19/21Report date:
Dan Findley - Mechanical Engineer 02/19/2021
03/08/2021
03/08/2021
denism