Loading...
HomeMy WebLinkAboutFile Documents.855 Chatfield Rd.0072-2020-BRES (11)Generated by REScheck-Web Software Compliance Certificate Project Chatfield View Energy Code:2015 IECC Location:Aspen, Colorado Construction Type:Single-family Project Type:New Construction Conditioned Floor Area:6,980 ft2 Glazing Area 53% Climate Zone:7 (9922 HDD) Permit Date: Construction Site:Owner/Agent:Designer/Contractor: Permit Number: Compliance: Passes using UA trade-off 2.0% Better Than Code Maximum UA:1425 Your UA:1396 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Compliance: Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value Prop. U-Factor Req. U-Factor Prop. UA Req. UA Membrane Ceiling: Flat Ceiling or Scissor Truss 3,703 39.0 10.0 0.023 0.026 85 96 Garage Ceiling: Flat Ceiling or Scissor Truss 760 49.0 0.0 0.026 0.026 20 20 Ceiling: Flat Ceiling or Scissor Truss 400 49.0 0.0 0.026 0.026 10 10 East Wall: Wood Frame, 16" o.c.1,608 32.0 6.0 0.034 0.045 31 41 Door 1: Glass Door (over 50% glazing)106 0.320 0.320 34 34 Window 1: Metal Frame w/ Thermal Break 591 0.320 0.320 189 189 North Wall: Wood Frame, 16" o.c.1,347 32.0 6.0 0.034 0.045 32 42 Window 2: Metal Frame w/ Thermal Break 405 0.320 0.320 130 130 South Wall: Wood Frame, 16" o.c.1,192 32.0 6.0 0.034 0.045 20 26 Window 3: Metal Frame w/ Thermal Break 611 0.320 0.320 196 196 West Wall: Wood Frame, 16" o.c.2,097 32.0 6.0 0.034 0.045 23 31 Door 2: Glass Door (over 50% glazing)1,058 0.320 0.320 339 339 Window 4: Metal Frame w/ Thermal Break 353 0.320 0.320 113 113 Floor: Slab-On-Grade (Heated) Insulation depth: 4.0'292 15.0 0.655 0.655 0 0 Project Title: Chatfield View Data filename:Page 1 of 2 09/26/22Report date: Construction Site: 855 Chatfield Rd Aspen, CO 81611 Owner/Agent: S2 Architects 215 S. Monarch Suite G-102 Aspen, CO 81611 Designer/Contractor: Dan Findley AEC 40801 US-6 #214 Avon, CO 81620 09/26/2022 justinh 09/26/2022 Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value Prop. U-Factor Req. U-Factor Prop. UA Req. UA Basement Wall 1: Solid Concrete or Masonry Wall height: 9.0' Depth below grade: 9.0' Insulation depth: 9.0' 2,136 0.0 15.0 0.041 0.050 80 98 Window: Metal Frame w/ Thermal Break 176 0.320 0.320 56 56 Garage door slab: Solid Concrete or Masonry Wall height: 0.3' Depth below grade: 0.0' Insulation depth: 0.0' 30 0.0 0.0 0.625 0.050 19 2 Den Slab at Den Door: Solid Concrete or Masonry Wall height: 1.0' Depth below grade: 0.0' Insulation depth: 0.0' 17 0.0 0.0 0.625 0.050 11 1 Entry door slab: Solid Concrete or Masonry Wall height: 0.3' Depth below grade: 0.0' Insulation depth: 0.0' 12 0.0 0.0 0.625 0.050 8 1 Name - Title Signature Date Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Project Title: Chatfield View Data filename:Page 2 of 2 09/26/22Report date: 8/30/22 09/26/2022