HomeMy WebLinkAboutFile Documents.855 Chatfield Rd.0072-2020-BRES (11)Generated by REScheck-Web Software
Compliance Certificate
Project Chatfield View
Energy Code:2015 IECC
Location:Aspen, Colorado
Construction Type:Single-family
Project Type:New Construction
Conditioned Floor Area:6,980 ft2
Glazing Area 53%
Climate Zone:7 (9922 HDD)
Permit Date:
Construction Site:Owner/Agent:Designer/Contractor:
Permit Number:
Compliance: Passes using UA trade-off
2.0% Better Than Code Maximum UA:1425 Your UA:1396
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Compliance:
Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade
assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements.
Envelope Assemblies
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value
Prop.
U-Factor
Req.
U-Factor
Prop.
UA
Req.
UA
Membrane Ceiling: Flat Ceiling or Scissor Truss 3,703 39.0 10.0 0.023 0.026 85 96
Garage Ceiling: Flat Ceiling or Scissor Truss 760 49.0 0.0 0.026 0.026 20 20
Ceiling: Flat Ceiling or Scissor Truss 400 49.0 0.0 0.026 0.026 10 10
East Wall: Wood Frame, 16" o.c.1,608 32.0 6.0 0.034 0.045 31 41
Door 1: Glass Door (over 50% glazing)106 0.320 0.320 34 34
Window 1: Metal Frame w/ Thermal Break 591 0.320 0.320 189 189
North Wall: Wood Frame, 16" o.c.1,347 32.0 6.0 0.034 0.045 32 42
Window 2: Metal Frame w/ Thermal Break 405 0.320 0.320 130 130
South Wall: Wood Frame, 16" o.c.1,192 32.0 6.0 0.034 0.045 20 26
Window 3: Metal Frame w/ Thermal Break 611 0.320 0.320 196 196
West Wall: Wood Frame, 16" o.c.2,097 32.0 6.0 0.034 0.045 23 31
Door 2: Glass Door (over 50% glazing)1,058 0.320 0.320 339 339
Window 4: Metal Frame w/ Thermal Break 353 0.320 0.320 113 113
Floor: Slab-On-Grade (Heated)
Insulation depth: 4.0'292 15.0 0.655 0.655 0 0
Project Title: Chatfield View
Data filename:Page 1 of 2
09/26/22Report date:
Construction Site:
855 Chatfield Rd
Aspen, CO 81611
Owner/Agent:
S2 Architects
215 S. Monarch Suite G-102
Aspen, CO 81611
Designer/Contractor:
Dan Findley
AEC
40801 US-6 #214
Avon, CO 81620
09/26/2022
justinh
09/26/2022
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value
Prop.
U-Factor
Req.
U-Factor
Prop.
UA
Req.
UA
Basement Wall 1: Solid Concrete or Masonry
Wall height: 9.0'
Depth below grade: 9.0'
Insulation depth: 9.0'
2,136 0.0 15.0 0.041 0.050 80 98
Window: Metal Frame w/ Thermal Break 176 0.320 0.320 56 56
Garage door slab: Solid Concrete or Masonry
Wall height: 0.3'
Depth below grade: 0.0'
Insulation depth: 0.0'
30 0.0 0.0 0.625 0.050 19 2
Den Slab at Den Door: Solid Concrete or Masonry
Wall height: 1.0'
Depth below grade: 0.0'
Insulation depth: 0.0'
17 0.0 0.0 0.625 0.050 11 1
Entry door slab: Solid Concrete or Masonry
Wall height: 0.3'
Depth below grade: 0.0'
Insulation depth: 0.0'
12 0.0 0.0 0.625 0.050 8 1
Name - Title Signature Date
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Project Title: Chatfield View
Data filename:Page 2 of 2
09/26/22Report date:
8/30/22
09/26/2022